HomeMy WebLinkAboutB16-0266_A002a_1498075761.pdfCLEAR FLOOR SPACE -
RECTANGLE 30"x48"
TURNING SPACE -
CIRCULAR
TURNING SPACE -
T-SHAPED
5'-0"
x > 24"
ALCOVE CLEAR SPACE
(FORWARD APPROACH) -
RECTANGLE 36"x48"
ALCOVE CLEAR SPACE
(PARALLEL APPROACH) -
RECTANGLE 30"x60"
x > 15"
ACCESSIBLE TURNING SPACE & CLEAR SPACE
5'-0" 2'-0"
1'-0" 3'-0" 1'-0"
5'-0"
3'-0"
4'-0"
2'-6"
4'-0"
3'-0" 2'-6"
5'-0"
FRONT APPROACH
POCKET OR HINGE APPROACH
SIDE APPROACH STOP OR LATCH APPROACH
DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
3'-6"
3'-6"
3'-6"
4'-0"
2'-0" 1'-10"
FRONT APPROACH,
PULL SIDE
FRONT APPROACH,
PUSH SIDE
FRONT APPROACH,
PUSH SIDE (WITH
CLOSER & LATCH)
HINGE APPROACH,
PULL SIDE (OPTION A)
HINGE APPROACH,
PULL SIDE (OPTION B)
HINGE APPROACH,
PUSH SIDE
HINGE APPROACH,
PUSH SIDE (WITH
CLOSER & LATCH)
LATCH APPROACH,
PULL SIDE (WITH
CLOSER)
LATCH APPROACH,
PUSH SIDE
LATCH APPROACH,
PUSH SIDE (WITH
CLOSER)
32" MIN.
FRONT
APPROACH:
HINGE
APPROACH:
LATCH
APPROACH:
LATCH APPROACH,
PULL SIDE
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS & GATES
5'-0"
1'-6" 4'-0"
4'-0"
1'-0"
5'-0" 3'-0"
4'-6"
3'-6"
3'-6"
1'-10" 4'-0"
1'-0" 1'-10"
4'-0" 2'-0"
4'-6"
2'-0"
2'-0"
3'-6"
2'-0"
4'-0"
34" - 38" 34" - 38"
4'-0"
MAX.
1'-3"
MIN.
4'-0"
MAX.
3'-8"
MAX.
4'-0"
MAX.
4'-0"
MAX.
3'-10"
MAX.
2'-10"
MAX.
2'-10"
MAX.
1'-3"
MIN.
UNOBSTRUCTED
FORWARD REACH
OBSTRUCTED HIGH
FORWARD REACH
OBSTRUCTED
HIGH FORWARD
REACH
UNOBSTRUCTED
SIDE REACH
OBSTRUCTED
HIGH SIDE REACH
OBSTRUCTED HIGH
SIDE REACH
HANDRAIL
HEIGHT AT
STAIRS
HANDRAIL
HEIGHT AT
RAMPS
X = TREAD DEPTH
TOP HANDRAIL
EXTENSION AT
STAIRS
BOTTOM
HANDRAIL
EXTENSION AT
STAIRS
TOP AND BOTTOM
HANDRAIL EXTENSION
AT RAMPS
X X
1'-0"
MIN.
1'-0"
MIN.
1'-0"
MIN.
1'-8"
MAX
2'-1"
MAX
2'-3"
MAX.
6'-8"
MIN. REDUCED VERTICAL
CLEARANCE
10"
MAX.
10"
MAX.
2'-0"
MAX.
CARPET ON FLOOR
SURFACES
VERTICAL
CHANGES IN
LEVEL
(a) BEVELED
CHANGES IN LEVEL
(b) BEVELED
CHANGES IN LEVEL
1
2 1
2
1/2"
1/4" MAX.
1/4" - 1/2" MAX.
1/2"
1/4" 1/4"
CLR.
34"
27" AFF MAX TO BOT
OF REFLECTING
SURFACE OF MIRROR CLR
27"34" MAX.
AFF MAX TO BOT
OF REFLECTING
SURFACE OF MIRROR
MIN.
8"
27" MIN.
MIN.
9" MAX.
6"
MIN.
11"
EMPLOYEE RESTROOM
LAVATORY
PUBLIC RESTROOM
LAVATORY
KNEE & TOE CLEARANCE
AT LAVATORY
ACCESSIBLE
WATER CLOSET
ACCESSIBLE
WATER CLOSET
ACCESSIBLE
URINAL
STANDARD
URINAL
DRINKING FOUNTAIN
MAX.
12" 42" MIN.
40"40" 15" MIN.
7" - 9"
33" - 36"
39" - 41" 18" MIN.
39" - 41"
17" - 19"
18" MIN.
39" - 41" 33" - 36"
16" - 18"
36"
12" 24"
44" AFF
MAX.
17" MAX.
MIN.
13 1/2" EQ EQ EQ EQ
24"
30" CLR MIN.
38" - 43" SPOUT HT.
16"
27"
31"
36" SPOUT HT.
48" MAX.
DOOR OPERATED
PUSH-BUTTON
54" MIN.
TOILET ACCESSORY#
48" MAX
TA-1 TA-2 TA-3 TA-4 TA-5 TA-6 TA-7 TA-8 TA-9 TA-10 TA-11 TA-12 TA-13 TA-14
ILLUSTRATION:
ACCESSORY ITEM:
RESPONSIBILITY:
BLOCKING TYPE:
GRAB BAR - 18"
--
C2
GRAB BAR - 42"
--
C2
GRAB BAR - 36"
--
C2
SEAT COVER
DISPENSER
--
A1
WALL MOUNTED
SOAP DISPENSER
--
A1
MIRROR
--
C1
HOOK
--
C1
(OR DOOR MOUNTED)
WALL BUMP
--
A1
PAPER TOWEL
DISPENSER
--
A1
COMBINATION
PAPER TOWEL
DISPENSER
--
A2
SANITARY NAPKIN
DISPOSAL UNIT
--
A1
BABY CHANGING
STATION
--
C2
TOILET TISSUE
DISPENSER
--
C1
VENDOR
--
A1
SEAT COVER
SURFACE
COIN SLOT
NOTE: EQUIPMENT INDICATED IN DIAGRAM MAY OR MAY NOT BE USED ON THIS PROJECT. REFER TO EQUIPMENT PLAN(S), INTERIOR ELEVATIONS, ETC. FOR LOCATION AND QUANTITIES OF ITEMS. CONFIRM WITH OWNER ALL REQUIREMENTS FOR OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI) ITEMS.
MANUFACTURER: -- -- -- -- -- -- -- -- -- -- -- -- -- --39" - 41" MIN 18"
42"
36" MAX
33" MIN
36"
36" MAX
33" MIN 48" MAX
38" MAX 38" MAX 36"
48" MAX
48" MAX
11"
30" 48" MAX
MIN 19"
48" MAX
MODEL NUMBER: -- -- -- -- -- -- -- -- -- -- -- -- -- --
TA-15
AIR BLADE
--
A1
--
--41" MAX
34" MAX
27" MIN
2 1/2" MAX.
18" MIN.
20" - 24"
2" MAX.
17" - 19" BENCH BACK SUPPORT AND SEAT HEIGHT
12"
BACK OF
WALL
42" MIN.
12"
DRESSING ROOM BENCH
WITH BACK
42" MIN.
20" - 24"
DRESSING ROOM BENCH
WITHOUT BACK
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
10/12/2016
6:08:06 PM
GENERAL
ACCESSIBILITY
STANDARDS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A002a
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
NOTES - GENERAL ACCESSIBILITY
BUILDING AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN
ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE AND 2009 ICC A117.1.
DEFINITIONS:
ACCESSIBLE:
A SITE, BUILDING, FACILITY OR PORTION THEREOF THAT COMPLIES WITH THE REFERENCED
CODES.
ACCESSIBLE ROUTE:
A CONTINUOUS, UNOBSTRUCTED PATH THAT COMPLIES WITH THE CODES.
CIRCULATION PATH:
AN EXTERIOR OR INTERIOR WAY OF PASSAGE FROM ONE PLACE TO ANOTHER FOR
PEDESTRIANS.
COMMON USE:
INTERIOR OR EXTERIOR CIRCULATION PATHS, ROOMS, SPACES OR ELEMENTS THAT ARE
NOT FOR PUBLIC USE AND ARE MADE AVAILABLE FOR THE SHARED USE OF TWO OR MORE
PEOPLE.
EMPLOYEE WORK AREA:
ALL OR ANY PORTION OF ASPACE USED ONLY BY EMPLOYEES AND ONLY FOR WORK.
CORRIDORS, TOILET ROOMS, KITCHENETTES AND BREAK ROOMS ARE NOT EMPLOYEE
WORK AREAS.
FACILITY:
ALL OR ANY PORTION OF BULIDINGS, STRUCTURES, SITE IMPROVEMENTS, ELEMENTS AND
PEDESTRIAN OR VEHICULAR ROUTES LOCATED ON THE SITE.
PUBLIC ENTRANCE:
AN ENTRANCE THAT IS NOT A SERVICE ENTRANCE OR A RESTRICTED ENTRANCE.
PUBLIC-USE AREAS:
INTERIOR OR EXTERIOR ROOMS OR SPACES THAT ARE MADE AVAILABLE TO THE GENERAL
PUBLIC.
RESTRICTED ENTRANCE:
AN ENTRANCE THAT IS MADE AVAILABLE FOR COMMON USE ON A CONTROLLED BASIS, BUT
NOT PUBLIC USE, AND THAT IS NOT A SERVICE ENTRANCE.
SERVICE ENTRANCE:
AN ENTRANCE INTENDED PRIMARILY FOR DELIVERY OF GOODS OR SERVICES.
SITE:
A PARCEL OF LAND BOUNDED BY A LOT LINE OR A DESIGNATED PORTION OF A PUBLIC
RIGHT-OF-WAY
WHEELCHAIR SPACE:
A SPACE FOR A SINGLE WHEELCHAIR AND ITS OCCUPANT.
SCOPING REQUIREMENTS:
SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR
PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES.
SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES SHALL BE EXEMPT
FROM THESE REQUIREMENTS TO THE EXTENT SPECIFIED BELOW AND IN OTHER SECTIONS
OF THE AFORE REFERENCED ACCESSIBILITY CODES.
ACCESSIBILITY IS NOT REQUIRED IN BUILDINGS AND FACILITIES, OR PORTIONS THEREOF,
TO THE EXTENT PERMITTED BY 2012 VCC SECTIONS 1104 THROUGH 1110.
EXISTING BUILDINGS SHALL COMPLY WITH 2012 VIRGINIA REHABILITATION CODE SECTION
3409.
SECTION 1103.2.3 - EMPLOYEE WORK AREAS:
SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO
COMPLY WITH SECTIONS 907.5.2.3.2, 1107 AND 1104.3.1 AND SHALL BE DESIGNED AND
CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER AND EXIT
THE WORK AREA. WORK AREAS OR PORTIONS OF WORK AREAS, THAT ARE LESS THAN 150
SQUARE FEET IN AREA AND ELEVATED 7 INCHES OR MORE ABOVE THE GROUND OR
FINISHED FLOOR WHERE THE ELEVATION IS ESSENTIAL TO THE FUNCTION OF THE SPACE
SHALL BE EXEMPT FROM ALL REQUIREMENTS.
SECTION 1103.2.8 - LIMITED ACCESS SPACES:
NONOCCUPIABLE SPACES ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES,
FREIGHT ELEVATORS OR VERY NARROW PASSAGEWAYS ARE NOT REQUIRED TO BE
ACCESSIBLE.
SECTION 1103.2.9 - EQUIPMENT SPACES:
SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, REPAIR OR MONITORING
OF EQUIPMENT ARE NOT REQUIRED TO BE ACCESSIBLE. SUCH SPACES INCLUDE, BUT ARE
NOT LIMITED TO , ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL, ELECTRICAL OR
COMMUNICATIONS EQUIPMENT ROOMS, PIPING OR EQUIPMENT CATWALKS, WATER OR
SEWAGE TREATMENT PUMP ROOMS AND STATIONS, ELECTRIC SUBSTATIONS AND
TRANSFORMER VAULTS, AND HIGHWAY AND TUNNEL UTILITY FACILITIES.
SECTION 907.5.2.3.2 - EMPLOYEE WORK AREAS (REFERENCED ABOVE):
WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE NOTIFICATION
APPLIANCE CIRCUITS SERVING THE EMPLOYEE WORK AREAS SHALL BE INITIALLY
DESIGNED WITH A MINIMUM OF 20 PERCENT SPARE CAPACITY TO ACCOUNT FOR THE
POTENTIAL OF ADDING VISIBLE NOTIFICATION APPLIANCES IN THE FUTURE TO
ACCOMMODATE HEARING IMPAIRED EMPLOYEES.
SECTION 1007 - ACCESSIBLE MEANS OF EGRESS (REFERENCED ABOVE):
ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS
OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY
ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY
NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.
SECTION 1104.3.1 - EMPLOYEE WORK AREAS (REFERENCED ABOVE):
COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL BE
ACCESSIBLE ROUTES
EXCEPTIONS:
1. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE WORK AREAS THAT
ARE LESS THAN 300 SQUARE FEET IN SIZE AND DEFINED BY PERMANENTLY INSTALLED
PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS, SHALL NOT BE REQUIRED TO
BE ACCESSIBLE ROUTES.
2. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE USE AREAS, THAT
ARE AN INTEGRAL COMPONENT OF EQUIPMENT, SHALL NOT BE REQUIRED TO BE
ACCESSIBLE ROUTES.
3. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EXTERIOR EMPLOYEE WORK
AREAS THAT ARE FULLY EXPOSED TO THE WEATHER, SHALL NOT BE
REQUIRED TO BE ACCESSIBLE ROUTES.
SECTION 1105 - ACCESSIBLE ENTRANCES:
AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE.
EXCEPTIONS:
1. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO AREAS NOT REQUIRED TO BE
ACCESSIBLE.
2. LOADING AND SERVICE ENTRANCES THAT ARE NOT THE ONLY ENTRANCE TO A TENANT
SPACE.
WHERE RESTRICTED ENTRANCES ARE PROVIDED TO A BUILDING OR FACILITY, AT LEAST
ONE RESTRICTED ENTRANCE TO THE BUILDING OR FACILITY SHALL BE ACCESSIBLE.
IF A SERVICE ENTRANCE IS THE ONLY ENTRANCE TO A BUILDING OR A TENANT SPACE IN A
FACILITY, THAT ENTRANCE SHALL BE ACCESSIBLE.
AT LEAST ONE ACCESSIBLE ENTRANCE SHALL BE PROVIDED TO EACH TENANT IN A
FACILITY. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO TENANTS THAT ARE NOT
REQUIRED TO BE ACCESSIBLE.
SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES
WHERE PARKING IS PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN
COMPLIANCE WITH REFERENCED CODE SECTIONS AND TABLES.
TEN PERCENT OF PATIENT AND VISITOR PARKING SPACES PROVIDED TO SERVE HOSPITAL
OUTPATIENT FACILITIES SHALL BE ACCESSIBLE.
FOR EVERY SIX OR A FRACTION OF SIX ACCESSIBLE SPACES, AT LEAST ONE SHALL BE A
VAN-ACCESSIBLE PARKING SPACE.
NOTHING IN THE REFERENCED STANDARDS IS INTENDED TO PREVENT THE USE OF
DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED
PROVIDED THEY RESULT IN EQUIVALENT OR GREATER ACCESSIBILITY AND SUCH
EQUIVALENCY IS APPROVED BY THE AUTHORITY HAVING JURISDICTION.
THE AUTHORITY HAVING JURISDICTION SHALL PROVIDE AN APPROPRIATE REVIEW AND
APPROVAL PROCESS TO ENSURE COMPLIANCE WITH ADOPTED STANDARDS.
ADAAG AND ICC A117.1 ARE SUBJECT TO VARIOUS AND POSSIBLE CONTRADICTORY
INTERPRETATIONS. THE ARCHITECT, THEREFORE, WILL USE REASONABLE PROFESSIONAL
EFFORTS AND JUDGEMENTS TO INTERPRET APPLICABLE ACCESSIBILITY REQUIREMENTS
AS THEY PERTAIN TO PHYSICAL BARRIERS AND AS THEY APPLY TO THE PROJECT. THE
ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE
PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH ACCESSIBILITY
REQUIREMENTS AND/OR THE REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL
LAWS, RULES, CODES, ORDINANCES AND REGULATIONS THAT APPLY TO THE PROJECT.
SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES
STANDARDS - ACCESSIBLE CLEAR SPACE AND MANEUVERING CLEARANCES
STANDARDS - FLOOR SURFACES
STANDARDS - ACCESSIBLITY DIAGRAMS
STANDARDS - TOILET ACCESSORY MOUNTING DIAGRAMS
STANDARDS - TOILET FIXTURE MOUNTING DIAGRAMS
STANDARDS - DRESSING ROOM CLEARANCES
2 09/19/2016 CCD-002
10/17/2016
06/21/17