FIRE ALARM AUDIO/VISUAL DEVICES
DOORBELL DISABLE
SWITCH
FINISHED FLOOR
GUESTROOM SIDE OF DOOR
SYMBOL DEVICE REMARKS
BUTTON FOR DOOR SIGNAL
2-GANG BOX WITH
TRANSFORMER FOR DOOR BELL
DOORBELL DISABLE SWITCH
HORN STROBE FOR DOOR SIGNAL BEDROOMS)
REMOTE STROBE DOOR SIGNAL (BATHROOMS)
OUTSIDE DOOR ON STRIKE SIDE, +48" AFF
FACTORY LABEL ON COVER PLATE
MOUNT IN SOFFIT OR CABINET - PROVIDE ACCESS
PROVIDE KEY SWITCH IN CORRIDOR ABOVE THE PUSH
BUTTON TO TURN ON/OFF THE REQUIRED DOORBELL KIT.
GANG WITH LIGHT SWITCH "DOORBELL DISABLE SWITCH"
PLAQUE ON WALL BEHIND EVERY ENTRY DOOR, ROOM
SIDE.
MOUNT 80" AFF
MOUNT 80" AFF
HI-CF NOTES:
PROVIDE ASSISTIVE LISTENING DEVICES IN THE REQUIRED NUMBER OF ROOMS PER BUILDING CODES AND DOJ 2010 ADA
STANDARDS FOR ACCESSIBLE DESIGN.
1. DISTRIBUTE HEARING IMPAIRED ROOMS AMONGST ALL CLASSES OF ROOMS INCLUDING SUITES.
2. PLAQUES (EXCEPT AS NOTED): PROVIDE AS INDICATED. PLAQUES SHALL BE BLACK PHENOLIC WITH 1/4" WHITE ENGRAVED LETTERS.
3. PROVIDE TELEPHONE WITH VOLUME CONTROL AND SIGNAL NOTIFICATION LIGHT.
4. LOCATE TELEPHONES WITHIN 48" OF AN ELECTRICAL OUTLET.
5. PROVIDE EDWARDS 7005-65 HOTEL ROOM ANNUNCIATOR KIT WITH ONE ADDITIONAL STROBE AT EACH BATHROOM IN HI ROOMS.
DEVICES FOR THE HEARING IMPAIRED COMPLIANT FEATURES:
J
PB
J T
DDS
H
A A
SYMBOL DEVICE REMARKS
SMOKE DETECTOR
ELECTRICAL PANEL
SMOKE DETECTOR WITH STROBE
FIRE ALARM HORN
FIRE ALARM HORN STROBE
REMOVE EXISTING BATTERY POWERED SMOKE DETECTOR
EXISTING ELECTRICAL PANEL
PROVIDE SMOKE DETECTOR WITH STROBE & BATTERY
BACK-UP
REMOVE EXISTING FIRE ALARM HORN ANNUNCIATOR
PROVIDE ADDRESSABLE HORN STROBE
HI-FA NOTES:
PROVIDE FIRE ALARM SYSTEM UPGRADES IN GUESTROOMS WITH HEARING IMPAIRED COMPLIANT FEATURES PER BUILDING CODES AND DOJ
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN.
1. GUESTROOM FIRE ALARM (FA) ADDRESSABLE ANNUNCIATING DEVICES ARE CONNECTED TO EXISTING BUILDING FA PANEL IN THE HOTEL
LOBBY. THEY ARE ACTIVATED BY EXISTING HARD-WIRED SMOKE DETECTORS, FA PULL STATION AND OTHER EXISTING SIGNALING DEVICES
LOCATED IN GUEST BUILDING CORRIDORS AND STAIRWELLS.
2. GENERAL CONTRACTOR TO COORDINATE INSTALLATION OF NEW FA DEVICES WITH FIRE ALARM SYSTEMS VENDOR.
3. FIRE ALARM SYSTEMS VENDOR TO PROVIDE ADDITIONAL DOCUMENTATION REQUIRED BY LOCAL MUNICIPALITY / AUTHORITY HAVING
JURISDICTION (AHJ) PER PLAN AND SECURE REQUIRED FA PERMITS.
4. SMOKE DETECTORS:
A - REMOVE EXISTING BATTERY POWERED SMOKE DETECTOR (SD)
B - PROVIDE SDS WITH BATTERY BACK-UP (EXISTING SYSTEM COMPATIBLE) HARD-WIRED TO 120V POWER. SDS TO HAVE 520HZ, LOW
FREQUENCY SOUNDER BASE, WHERE REQUIRED BY JURISDICTION PER NFPA 72.
C - PROVIDE ADDITIONAL SDS DEVICES PER PLAN, INTER-CONNECTED TO PROVIDE NOTIFICATION THROUGHOUT GUESTROOM UNIT.
ALTERNATE: PROVIDE REMOTE FA STROBE & COMPONENTS PER SDS MFR. TO LINK REMOTE GUESTROOMS FS TO NEW GUESTROOM SDS.
(THESE ALTERNATE STROBE DEVICES ARE NOT TO BE CONNECTED TO BUILDING FIRE ALARM SYSTEM; THEY ARE PART OF LOCAL
GUESTROOM NOTIFICATION ONLY).
5. ADDRESSABLE ANNUNCIATING DEVICES:
A - DISCONNECT & REMOVE EXISTING ADDRESSABLE FA HORN DEVICES.
B - PROVIDE ADDRESSABLE FA HORN-STROBE THAT IS COMPATIBLE WITH EXISTING BUILDING FIRE ALARM SYSTEM
C - PROVIDE REMOTE FA STROBE DEVICE PER PLAN, CONNECTED TO BUILDING FA SYSTEM THROUGH ORIGINAL FA HORN DEVICE WIRING
DEVICES FOR HI- FIRE ALARM UPGRADES:
REMOTE FIRE ALARM STROBE PROVIDE ADDRESSABLE HORN STROBE
SD
EP
S
SDS
H F
H F
S
F
SMOKE STROBE, REMOTE PROVIDE REMOTE STROBE CONNECTED TO SMOKE
DETECTOR SS
CORRIDOR SIDE OF DOOR
3'-10"
DOORBELL
FINISHED FLOOR
DOORBELL
DISABLE KEY
SWITCH
H
A A
DDS
J T
J
PB
TRANSFORMER LOCATION
MAY VARY BY ROOM TYPE.
ALWAYS ENDEAVOR TO HIDE
FROM GUEST VIEW WHILE
PROVIDING VENTILATION AND
ACCESS FOR MAINTENANCE.
LOCATE DOORBELL DISABLE
SWITCH NEXT TO WELCOME
LIGHT SWITCH - DO NOT GANG
BOX. PROVIDE SEPARATE
LABELED COVERPLATE (TYPICAL)
H F
S
S F SDS
TO NEAREST ELECTRICAL
PANEL WITH CAPACITY
SS
H
F S
S F
SDS
TO NEAREST ELECTRICAL
PANEL WITH CAPACITY SS
UP TO LOFT LEVEL
H A A DDS
J
T
TRANSFORMER LOCATION
MAY VARY BY ROOM TYPE.
ALWAYS ENDEAVOR TO HIDE
FROM GUEST VIEW WHILE
PROVIDING VENTILATION AND
ACCESS FOR MAINTENANCE.
LOCATE DOORBELL DISABLE
SWITCH NEXT TO WELCOME
LIGHT SWITCH - DO NOT GANG
BOX. PROVIDE SEPARATE
LABELED COVERPLATE (TYPICAL)
J
PB
UP TO LOFT LEVEL
H A A FROM LOWER LEVEL
HF
S
S
F
SDS
SS
FROM LOWER LEVEL
TO NEAREST ELECTRICAL
PANEL WITH CAPACITY
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
11:13:54 AM
HEARING IMPAIRED
ROOM TYPES -
PLANS, ELEVATION &
LEGEND
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
A003
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
1. DISCONNECT & REMOVE ONLY HI-CF DEVICES AND ALL ASSOCIATED WIRING.
2. PROVIDE BLANK COVER PLATES FOR REMAINING BACK BOXES.
ALTERNATE: REMOVE BACK BOX AND PATCH WALL & FINISH TO MATCH EXISTING.
3. DO NOT RE-USE ANY HEARING IMPAIRED DEVICES REMOVED FOR
DECOMMISSIONING.
HI-CF DECOMMISSIONING NOTES:
WHERE HI-CF ROOM IS DESIGNATED TO BE DECOMMISSIONED:
ABBREVIATIONS:
HI - CF: HEARING IMPAIRED - COMMUNICATION FEATURE
HI - FA: HEARING IMPAIRED - FIRE ALARM
SCALE: 3/8" = 1'-0"
2DTYP DEVICE MOUNTING HEIGHTS
**NOTE: HI-CF PLAN COMPONENTS ARE IN ADDITION TO
HI-FA COMPONENTS SHOWN IN PLANS ABOVE. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.
*NOTE: HI-FA PLAN COMPONENTS ARE IN ADDITION TO
HI-CF COMPONENTS SHOWN IN PLANS BELOW. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.
SCALE: 3/8" = 1'-0"
2ETYP DEVICE MOUNTING HEIGHTS
SCALE: 1/4" = 1'-0" DRAWING REF: A112
2AKING/ QUEEN QUEEN/ KING SUITE HI-CF UPGRADE PLAN (TYPICAL)
SCALE: 1/4" = 1'-0" DRAWING REF: A1122BKING/ QUEEN QUEEN/ KING SUITE HI-FA UPGRADE PLAN (TYPICAL)
SCALE: 1/4" = 1'-0"
4BKING CONDO LOWER LEVEL HI-FA UPGRADE PLAN (TYPICAL)
SCALE: 1/4" = 1'-0"4AKING CONDO LOWER LEVEL HI-CF UPGRADE PLAN (TYPICAL)
SCALE: 1/4" = 1'-0"
6AKING CONDO LOFT LEVEL HI-CF UPGRADE PLAN (TYPICAL)
SCALE: 1/4" = 1'-0" 6BKING CONDO LOFT LEVEL HI-FA UPGRADE PLAN (TYPICAL)
**NOTE: HI-CF PLAN COMPONENTS ARE IN ADDITION TO
HI-FA COMPONENTS SHOWN IN PLANS ABOVE. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.
*NOTE: HI-FA PLAN COMPONENTS ARE IN ADDITION TO
HI-CF COMPONENTS SHOWN IN PLANS BELOW. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.
**NOTE: HI-CF PLAN COMPONENTS ARE IN ADDITION TO
HI-FA COMPONENTS SHOWN IN PLANS ABOVE. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.
*NOTE: HI-FA PLAN COMPONENTS ARE IN ADDITION TO
HI-CF COMPONENTS SHOWN IN PLANS BELOW. OMITTED
FOR CLARITY PURPOSES ONLY.
PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE
NOTED.