HomeMy WebLinkAboutB16-0266_A020_1491490904.pdfLINE OF STRUCTURE LINE OF CEILING LINE OF STRUCTURE FACE OF CMU, CONC, OR EXIST WALL F A W FACE OF CMU, CONC, OR EXIST WALL 3/4" WOOD FURRING STRIPS FINISH MATERIAL PARTITION GRAPHIC 3 HR SMOKE COMPARTMENT BARRIER 2 HR SMOKE COMPARTMENT BARRIER 2 HR FIRE BARRIER 1 HR SMOKE COMPARTMENT BARRIER 1 HR FIRE BARRIER NON-RATED SMOKE RESISTIVE PARTITION 3 HR FIRE BARRIER NON-RATED PARTITION (F) (H) (E) (D) (C) (B) (G) (a) UNDERSIDE OF DECK OR SLAB ROOF/FLR. 22 GA. MTL TOP TRACK (TYP. U.N.O.) CEILING LINE MOUNTING DETAIL B 22 GA. BOTTOM TRACK (TYP.) FLOOR LINE 18 GA. STUDS AT WALL MOUNTED ARCHITECTURAL CABINETS / MILLWORK / ATTACHED SHELVING AND STONE VENEER 4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX. DOUBLE STUDS DOUBLE STUDS ABOVE CEILING OPENING LARGE ABOVE CEILING OPENING DOOR OPENING DOUBLE DOOR OPENING BELOW CEILING OPENING LARGE BELOW CEILING OPENING NOTES: 1. ALL STUDS ARE SPACED 16" O.C. MAXIMUM. 2. ALL STUDS SHALL BE "C" STUDS WITH 1/4" FLANGE MINIMUM. 3. DENOTES SHELVING OR CABINETRY. 4. STUDS BEHIND BASE CABINETRY MAY BE TYPICAL STUDS. 5. IN NO CASE SHALL DOUBLE STUDS AT SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEMS. 06 03 01 05 02 05 01 03 04 01 TYPICAL FRAMING DOUBLE STUDS DOUBLE STUDS 3'-2 7/8" LOWER PRIORITY WALL HIGHER PRIORITY WALL PARTITION PRIORITY LEGEND NOTE: MAINTAIN SHEATHING ON HIGHER PRIORITY WALL AT INTERSECTION WITH LOWER PRIORITY WALL AS INDICATED. FOR WALL PRIORITIES REFERENCE PARTITION PRIORITY LEGEND. * TABLE DOES NOT INCLUDE 3 AND 4 HOUR RATED PARTITIONS PRIORITY 1 - HIGHEST PRIORITY 2 PRIORITY 2 PRIORITY 3 PRIORITY 4 PRIORITY 5 - LOWEST ONE HOUR CONSTRUCTION TAPE & JT COMP., TYP. JAMB STUDS AS REQ'D. HOLLOW METAL FRAME 3 5/8" METAL STUDS 5/8" TYPE "X" GYP. BD TWO HOUR CONSTRUCTION HIGHER PRIORITY WALL 1 LAYER AT ONE HOUR SMOKE PARTITION LOWER PRIORITY WALL HIGHER PRIORITY WALL CORNER BEAD, TYP. 3 5/8" METAL STUD LOCATED AT ABUTTING WALL AND ATTACHED THRU GYPSUM WALLBOARD TO STUD OF ABUTTING WALL 5/8" GYPSUM WALLBOARD - NUMBER OF LAYERS PER PARTITION TYPE GYPSUM WALLBOARD 3 5/8" METAL STUD LOCATED AT ABUTTING WALL AND ATTACHED THRU GYPSUM WALLBOARD TO STUD OF ABUTTING WALL TAPE & JOINT COMPOUND TWO HOUR FIRE & SMOKE PARTITION TWO HOUR FIRE PARTITION TWO HOUR SHAFT PARTITION ONE HOUR FIRE & SMOKE PARTITION ONE HOUR FIRE PARTITION NON RATED PARTITION CONTINUE 2" WIDE x 22 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD WHERE GYP BD IS CONCURRENT WITH DECK FLUTE RECESS, EXTEND UP INTO RECESS AS SHOWN EXTEND ONE LAYER UP INTO FLUTE RECESS AND SEAL 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO STEEL DECK AT 12" O.C. MAX. WHEN PARTITION IS ALIGNED AT DECK FLUTE RECESS - PROVIDE CONTINUOUS 10" 22 GA MTL PLATE AT DECK FLUTE RECESS THAT IS CONTIGUOUS WITH PARTITION - ATTACH METAL PLATE TO DECK WITH POWER DRIVEN FASTENERS SEAL ONE SIDE OF PARTITION AGAINST PASSAGE OF SMOKE CONTINUE 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL - ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO PLATE OR STEEL DECK AT 12" O.C. MAX. CONTINUE 2" WIDE x 22 GA MTL STRAP, ATTACH GYP BD TO STRAP AT 8" O.C. MAX. CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE. RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. FILL DECK FLUTE RECESS WITH SAFING INSULATION - CAP ENDS OF INSULATION WITH 1/2" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE., RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. CAP ENDS OF INSULATION WITH 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL - ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. FILL DECK FLUTE RECESS WITH SAFING INSULATION FILL DECK FLUTE RECESS WITH SAFING INSULATION 1/2" THICK FIRE/SMOKE RESISTANT FILL MATERIAL. FILL DECK FLUTE RECESS (BOTH SIDES) POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) ONE HOUR RATED (UL-HW-D-0001) NON-RATED OR SMOKE RESISTANT CONT. 2" WIDE x 22 GA MTL STRAP, ATTACH GYP BD TO STRAP AT 8" O.C. MAX. 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO PLATE OR STEEL DECK AT 12" O.C. MAX. TWO HOUR RATED (UL-HW-D-0002) CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE. RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. CAP ENDS OF INSULATION WITH 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. CMU PARTITION - DEPENDING ON HOW COURSING INTERSECTS THE STEEL DECK, THE TOP COURSE OF BLOCK MAY BE REQUIRED TO BE CUT FILL DECK FLUTE RECESS W/ SAFING INSULATION CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" x 2 1/2" PIECE OF GYP BD USED FOR THE WALL POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL. FILL DECK FLUTE RECESS (BOTH SIDES) 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL TWO HOUR RATED (UL-HW-D-0009) CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL DOUBLE 20 GA. METAL STUDS 22 GA. METAL TRACK 1" x 22GA. METAL STRAP PLATES AT 3'-6" O.C. EACH SIDE CLIP ANGLE - 18 GA. x 1 1/2" x 11/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE E22 GA. METAL SILL TRACK BELOW 20 GA. METAL STUDS 22 GA. METAL TRACK DOUBLE 20 GA. METAL STUDS AT BOTH JAMBS 22 GA. METAL SILL TRACK BELOW 1" x 22 GA. METAL STRAP PLATES AT 3'- 6" O.C. EA. SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE DOUBLE 18 GA. 3 5/8" OR 6" METAL STUDS 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 06 04 03 01 02 05 TYPICAL FRAMING DETAILS 2 3/4" C.J. GYP. BD. SUSPENDED CEILING SYSTEM 24'-0" MAX 24'-0" MAX GYPSUM BOARD CEILING INTERIOR PARTITION NON-EXPOSED EDGE PARTITION INTERSECTION/ CHANGE IN CONSTRUCTION LINE OF PARTITION SEALANT AND BACKER ROD L-BEAD SOUND ATTENUATION BLANKET COMPRESSED TO FILL OPENING AT SOUND RATED PARTITION PARTITION 1/4" BACKER ROD & SEALANT "LC" BEAD PARTITION LINE OF PARTITION 3/8" NON-RATED DETAILS 11/16" 1/2" MAX 5/8" METAL TRIM CONTROL JOINTS EA SIDE METAL STUDS W/ 5/8" TYPE "X" GYP. BD. EA. SIDE 2 LAYERS OF 5/8" GYP. BD. SOUND ATTENUATION BLANKET, WHERE PARTITION CALLS FOR INSULATION 1 HR. RATED GYP. CONTROL JOINT REF PARTITION TYPE FOR INSULATION METAL TRIM CONTROL JOINTS EA SIDE METAL STUDS W/ 2 LAYERS 5/8" TYPE "X" GYP. BD. EA. SIDE 5/8" 1/2" MAX 2 HR. RATED GYP. CONTROL JOINT REF PARTITION TYPE FOR INSULATION RATED DETAILS TELEPHONE OR ELECTRICAL BOXES 1/2" OR 5/8" TYPE "X" GYP. BD. AS REQUIRED FOR TWO HOUR RATED FIRE OR SMOKE WALL TYPICAL STEEL STUD EACH 16 SQ. IN. MAX. TOTAL OPENING 100 SQ. IN./100 SQ. FT. (PER) UL 2'-0" MIN. SEAL BOXES WITH JOINT COMPOUND A = MTL STUD; DECK TO DECK; (1) LAYER GYP BD EA SIDE B = MTL STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE C = MTL STUD CHASE WALL; DECK TO DECK; (1) LAYER GYP BD EA SIDE D = MTL STUD; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD EA SIDE E = MTL STUD; PARTIAL HEIGHT; TO CEILING; (1) LAYER GYP BD EA SIDE F = MTL STUD FURRING; DECK TO DECK; (1) LAYER GP BD ON FINISH FACE G = MTL STUD FURRING; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD ON FINISH FACE L = MTL STUD; DECK TO DECK; (1) LAYER LEAD LINED GYP BD ON FINISH SIDE 'A'; (1) LAYER GYP BD ON FINISH SIDE 'B' M = CMU; DECK TO DECK N = CMU; PARTIAL HEIGHT; 6" ABOVE CEILING P = MTL STUD W/ STL ANGLE POSTS AT 4'-0" OC; PARTIAL HEIGHT; BELOW CEILING; (1) LAYER GYP BD EA SIDE S = MTL C-H STUD SHAFT WALL; DECK TO DECK; (1) LAYER GYP BD ON ROOM FINISH SIDE; (1) LAYER 1" SHAFT WALL LINER ON SHAFT SIDE T = MTL C-H STUD SHAFT WALL; DECK TO DECK; (2) LAYERS GYP BD ON ROOM FINISH SIDE; (1) LAYER 1" SHAFTWALL LINER ON SHAFT SIDE U = UNKNOWN PARTITION COMPOSITION W = WD STUD; DECK TO DECK; (1) LAYER GYP BD EA SIDE X = WD STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE Y = WD STUD; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD EA SIDE Z = WD STUD; PARTIAL HEIGHT; TO CEILING; (1) LAYER GYP BD EA SIDE PARTITION TYPE PARTITION TYPE NOMINAL WIDTH FIRE OR SMOKE RATING SEE NOMINAL WIDTH SCHEDULE BELOW SEE PARTITION GRAPHIC LEGEND BELOW DESIGNATION AS NOTED ON PARTITION TYPE BELOW PARTITION DESIGNATOR MTL. STUD GYP. BD. DETAIL "A1" CONT. 20 GA. 4" WIDE MTL. BACK-UP PLATE DETAIL "A2" CONT. 18 GA. 8" WIDE MTL. BACK-UP PLATE 3 5/8" MIN. (DEEPER IF REQUIRED) 14 GA. STL RUNNER TRACK -- CLIP FLANGES TO FIT OVER STUDS MTL WALL STUDS 2x8 (MIN.) WD. BLOCKING BETWEEN STUDS (DEEPER IF REQUIRED) CONT. 20 GA. 6" WIDE MTL BACK-UP PLATE (4) #2 WOOD SCREWS EACH END (3) 1/4"x3" WOOD SCREWS EACH END REFER TYPICAL MOUNTING HEIGHTS REFER TYPICAL MOUNTING HEIGHTS REFER TYPICAL MOUNTING HEIGHTS MIN. 18 GA. MTL STUDS DETAILS "A1 & A2" (SECTION VIEW) DETAIL "B" (ISOMETRIC VIEW) DETAILS "C1 & C2" (ISOMETRIC VIEW) C1: WOOD BLOCKING ONLY C2: WOOD BLOCKING W/ METAL BACK-UP PLATE 11 METAL STUD CMU 7/8" 1 5/8" 2 1/2" 3 5/8" 4" 6" N/A 11 5/8" 3 5/8" 5 5/8" 7 5/8" 9 5/8" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WOOD STUD N/A N/A N/A 3 1/2" 5 1/2" N/A 7 1/4" N/A N/A N/A N/A N/A 'U' WIDTH RANGE 0 - .99" 11" - 11.99" 3" - 3.99" 5" - 5.99" 7" - 7.99" 9" - 9.99" 1" - 1.99" 2" - 2.99" 4" - 4.99" 6" - 6.99" 8" - 8.99" 10" - 10.99" N/A # 12 10 9 8 7 6 5 4 3 2 1 N/A N/A 0 N/A 12" - 12.99" NOMINAL WIDTH SCHEDULE 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 10/12/2016 6:08:43 PM PARTITION TYPES, DETAILS, AND STANDARDS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A020 2211 N FRONTAGE RD, VAIL, COLORADO 81657 TYPE CONSTRUCTION DATA FIRE PARTITIONS STC RATING FRAMING / CORE SIZE OVERALL PARTITION WIDTH RATING UL DESIGNATION A - MTL STUD; DECK TO DECK; (1) LAYER FINISH MATERIAL EA SIDE A2a 2 1/2" 3 3/4" 0 HR A4a 3 5/8" 4 7/8" 0 HR A4b 3 5/8" 5 3/4" 0 HR A6a 6" 7 1/4" 0 HR F - MTL STUD FURRING; DECK TO DECK; (1) LAYER GYP BD ON FINISH FACE F1a 7/8" 1 1/2" 0 HR F2a 1 5/8" 2 1/4" 0 HR F3a 2 1/2" 3 1/8" 0 HR F4a 3 5/8" 4 1/4" 0 HR W - WOOD FURRING STRIPS; DECK TO DECK; (1) LAYER FINISH MATERIAL ON FINISH FACE W1a 3/4" 1 1/2" 0 HR NOTES - PARTITION TYPE 1. CONSTRUCTION OF FIRE RATED PARTITIONS SHALL BE IN ACCORDANCE WITH THE TESTING DESIGN DESIGNATED. ARCHITECTURAL DETAILS MAY NOT INDICATE EVERY REQUIRED COMPONENT OF TESTED ASSEMBLY. 2. PROVIDE CONTROL JOINTS IN ALL GYPSUM WALLBOARD PARTITIONS AT 30'-0" OC MAXIMUM OR AS INDICATED ON FLOOR PLANS. 3. ONE SIDE OF GYPSUM WALLBOARD MAY BE INSTALLED WHEN UNUSED SPACE (IE, UNDER STAIR) OR UNFINISHED TENANT SPACE EXISTS ON ONE SIDE, EXCEPT WHERE REQUIRED FOR FIRE RATING. 4. ALL STUD/ SPACING SHALL BE 16" OC UNLESS OTHERWISE NOTED. 5. PARTITION SYMBOL INDICATIONS ON FLOOR PLANS DESIGNATE THE ENTIRE LENGTH OF WALL INDICATED UNLESS INTERRUPTED BY ANOTHER SYMBOL. 6. UTILIZE EXTENDED TRACKS WITH SLOTTED HOLES AT TOPS OF PARTITIONS WHEREVER ATTACHING TO STRUCTURE ABOVE TO ALLOW FOR DEFLECTION. 7. PROVIDE FIRE BLOCKING FOR ALL PARTITIONS OPEN TO CEILING CAVITY. UTILIZE GYPSUM WALLBOARD WITH STEEL FRAMING WHERE SPACE IS TOO WIDE FOR SOLID STEEL OR INSULATION TYPE FIRE BLOCKING, UNLESS OTHERWISE INDICATED. PROVIDE IMPALING CLIPS WHERE REQUIRED TO SUPPORT INSULATION FIRE BLOCKING. 8. THE PARTITION TYPE SCHEDULE INCLUDES ONLY NEW PARTITIONS WITHIN THE SCOPE OF WORK. 9. SUBSTITUTE MOISTURE RESISTANT BOARD (PURPLE BOARD) FOR WET LOCATIONS (TOILETS, LOCKER ROOMS) OR WHERE SCHEDULED TO RECEIVE CERAMIC TILE OR STONE. FOR OTHER WET APPLICATIONS SUCH AS SHOWERS, USE CEMENTITIOUS TILE BACKER BOARDS. 10. ALL GYPSUM BOARDS SHALL BE 5/8" THICK AND HELD OFF 1/2" FROM FLOOR SURFACE, UNO. 11. PROVIDE CONTINUOUS SEALANT UNDER METAL TRACKS AND AT PERIMETER OF GYPSUM BOARD PANELS AT SMOKE RATED, STC RATED OR FIRE RATED ASSEMBLIES. 12. PROVIDE MARKINGS ABOVE SUSPENDED CEILINGS AND IN CONCEALED SPACES TO IDENTIFY FIRE RATED PARTITIONS. SUCH SIGNAGE SHALL BE 1" HIGH (MIN) LETTERS AND SHALL STATE "FIRE RATED ASSEMBLY" AT HORIZONTAL INTERVALS OF 8 FT. 13. METAL STUD PARTITIONS SCHEDULED TO SUPPORT WALL MOUNTED CASEWORK OR EQUIPMENT SHALL HAVE 33 MIL (20 GA) MIN STUDS FOR THE ENTIRE LENGTH OF THE CASEWORK. 14. PROVIDE WOOD OR METAL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING CASEWORK, GRAB BARS, SHELVING, HANDRAILS, TOILET PARTITIONS, ETC. REF TYP DETAILS FOR BLOCKING. 15. PROVIDE DOUBLED 33 MIL (20 GA) MIN STUDS AROUND ALL DOOR, WINDOW OR CASED OPENINGS. 16. ALL GYPSUM BOARD FOR FIRE RATED PARTITIONS SHALL BE "TYPE X", UNLESS OTHERWISE REQUIRED BY RATING DESIGN DESIGNATION. 17. REF. ENLARGED DETAILS AT TOPS OF FIRE RATED PARTITION HEAD DETAILS. 18. ORIENTATION OF SHAFT WALL ASSEMBLY MAY VARY FROM THAT SHOWN ON DRAWINGS AND MAY BE DETERMINED ON SITE AS REQUIRED AFTER CONSIDERATION IS MADE FOR STRUCTURAL OBSTRUCTIONS THAT PREVENT THE PROPER FASTENING OF GYPSUM BOARD. 19. WHERE INSULATION IS INDICATED, PROVIDE SOUND ATTENUATION BLANKETS (THERMAFIBER OR EQUAL). THERMAL FIBERGLASS INSULATION NOT ACCEPTABLE. 20. STC RATINGS ARE SHOWN FOR KNOWN TEST ASSEMBLIES FOR THE STUD SIZE INDICATED. FOR OTHER STUD SIZES COMPLY WITH REQUIREMENTS OF CLOSEST SIMILAR ASSEMBLY. 21. ALL PENETRATIONS IN FULL HEIGHT PARTITIONS SHALL BE SMOKE RESISTIVE AND FIRESTOPPED REGARDLESS OF THE PARTITION RATING. 22. PARTIAL-HEIGHT INSULATED PARTITIONS SHALL RECEIVE 1-LAYER OF CONTINUOUS 3" SOUND ATTENUATION BLANKETS ON TOP OF CEILING, EXTENDING 4'-0" FROM EACH SIDE OF PARTITION FACE, UNLESS OTHERWISE INDICATED. 23. FIRE-RATED PARTITIONS SHALL RECEIVE LISTED AND LABELED FIRE-RATED SEALANT SYSTEM (EACH SIDE) AT CONNECTION WITH UNDERSIDE OF STRUCTURAL DECK OR FIRE-PROOFED CEILING AND WITH FLOOR STRUCTURE. 24. ALL INTERIOR PARTITIONS SHALL RECEIVE BASE FINISH AS SCHEDULED, UNO. 25. ALL FULL-HEIGHT PARTITIONS TO RECEIVE CONTINUOUS SEALANT AT GAP BETWEEN GYP BD & STRUCTURE ABOVE, UNO. 26. CHASE WALL PARTITIONS SHALL RECEIVE 2 1/2" MTL STUD BRACES OR GYP GUSSET CONNECTING STUDS SPACED VERTICALLY 4'-0" OC, UNO. 27. PARTIAL HEIGHT MTL STUD PARTITIONS AT OR ABOVE CEILING HEIGHT SHALL RECEIVE CONTINUOUS STUD TOP TRACK W/ 2 1/2" 33 MIL (20 GA) MTL STUD BRACES AT 4'-0" OC MAX, ALTERNATING SIDES, UNO. 28. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE 'L' BEAD AT GYP BD CEILING CONNECTION, UNO. 29. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE PARTITION CLIP FOR ATTACHMENT W/ DIAGONAL BRACING ABOVE CEILING, UNO. PROVIDE DIAGONAL BRACING FOR ACOUSTICAL CEILING PANELS. 30. ALL LEAD-LINED GYP BD TO EXTEND 7'-0" AFF, UNO. 31. ALL FULL-HEIGHT MASONRY PARTITIONS TO RECEIVE COMPRESSIBLE FILLER AT CONNECTION WITH STRUCTURE ABOVE, UNO. 32. ALL MASONRY PARTITIONS TO RECEIVE HORIZONTAL MASONRY REINFORCEMENT AT 16" OC VERTICALLY, UNO. 33. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE 3"x3"x5/16" STEEL ANGLE POSTS WELDED TO 8"x3 1/2"x3/8" STEEL FLOOR PLATE AND 3"x3"x5/16" TOP ANGLE. PROVIDE 1" DIA HOLE IN STEEL ANGLE POSTS FOR CONDUIT. ATTACH STEEL FLOOR PLATE TO FLOOR STRUCTURE W/ (3) 3/8" DIA ANCHOR BOLTS. 34. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE GYP BD CAP & WOOD BLOCKING ATTACHED TO STEEL TOP ANGLE, UNLESS OTHER TRIM IS INDICATED. 35. ALL SHAFT WALL PARTITIONS SHALL RECEIVE J-STUD RUNNER (24 GA MIN) ATTACHED TO FLOOR STRUCTURE AND C-H MTL STUDS SPACED @ 24" OC. 36. WOOD STUD PARTITIONS SUPPORTED ON FLOORS W/ GYPSUM TOPPING SHALL HAVE DOUBLE SILL PLATES. 37. SECURE SILL PLATES ON WOOD I-JOISTS OR TRUSS-SUPPORTED FLOORS THROUGH SUBFLOOR AND INTO STRUCTURAL SUPPORT. SCHEDULE - PARTITION TYPE STANDARDS - PARTITION TYPE DESIGNATION DIAGRAMS LEGEND - PARTITION TYPE DESIGNATIONS STANDARDS - PARTITION HEAD DETAILS STANDARDS - TYPICAL NON-LOAD-BEARING PARTITION FRAMING AND DETAILS STANDARDS - RATED WALL INTERSECTIONS STANDARDS - CONTROL JOINT DETAILS STANDARDS - ADJACENT ELECTRICAL BOXES STANDARDS - BLOCKING AND MOUNTING DIAGRAMS SEALANT 1 08/25/2016 Revision 1 10/17/2016 04/06/17