HomeMy WebLinkAboutB16-0266_A020_1498075740.pdfLINE OF
STRUCTURE
LINE OF
CEILING
LINE OF
STRUCTURE
FACE OF CMU,
CONC, OR
EXIST WALL
F A
W
FACE OF CMU,
CONC, OR EXIST
WALL
3/4" WOOD FURRING
STRIPS
FINISH MATERIAL
PARTITION GRAPHIC
3 HR SMOKE
COMPARTMENT BARRIER
2 HR SMOKE
COMPARTMENT BARRIER
2 HR FIRE BARRIER
1 HR SMOKE
COMPARTMENT BARRIER
1 HR FIRE BARRIER
NON-RATED SMOKE
RESISTIVE PARTITION
3 HR FIRE BARRIER
NON-RATED PARTITION
(F)
(H)
(E)
(D)
(C)
(B)
(G)
(a)
UNDERSIDE OF DECK
OR SLAB ROOF/FLR.
22 GA. MTL TOP TRACK
(TYP. U.N.O.)
CEILING LINE
MOUNTING
DETAIL B
22 GA. BOTTOM
TRACK (TYP.)
FLOOR LINE
18 GA. STUDS
AT WALL MOUNTED ARCHITECTURAL
CABINETS / MILLWORK /
ATTACHED SHELVING AND
STONE VENEER
4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX.
DOUBLE STUDS
DOUBLE STUDS
ABOVE CEILING
OPENING
LARGE
ABOVE CEILING
OPENING
DOOR
OPENING
DOUBLE
DOOR
OPENING
BELOW
CEILING
OPENING
LARGE BELOW
CEILING
OPENING
NOTES:
1. ALL STUDS ARE SPACED 16" O.C. MAXIMUM.
2. ALL STUDS SHALL BE "C" STUDS WITH 1/4" FLANGE MINIMUM.
3. DENOTES SHELVING OR CABINETRY.
4. STUDS BEHIND BASE CABINETRY MAY BE TYPICAL STUDS.
5. IN NO CASE SHALL DOUBLE STUDS AT SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEMS.
06
03
01
05
02
05
01 03
04
01
TYPICAL FRAMING
DOUBLE STUDS DOUBLE STUDS
3'-2 7/8"
LOWER
PRIORITY
WALL
HIGHER PRIORITY
WALL
PARTITION PRIORITY LEGEND
NOTE: MAINTAIN SHEATHING ON HIGHER PRIORITY WALL AT
INTERSECTION WITH LOWER PRIORITY WALL AS INDICATED. FOR
WALL PRIORITIES REFERENCE PARTITION PRIORITY LEGEND.
* TABLE DOES NOT INCLUDE 3 AND 4 HOUR RATED PARTITIONS
PRIORITY 1 - HIGHEST
PRIORITY 2
PRIORITY 2
PRIORITY 3
PRIORITY 4
PRIORITY 5 - LOWEST
ONE HOUR
CONSTRUCTION
TAPE & JT COMP.,
TYP.
JAMB STUDS AS REQ'D.
HOLLOW
METAL
FRAME
3 5/8"
METAL
STUDS
5/8" TYPE
"X" GYP. BD
TWO HOUR
CONSTRUCTION
HIGHER PRIORITY
WALL
1 LAYER AT
ONE HOUR
SMOKE
PARTITION
LOWER PRIORITY WALL
HIGHER PRIORITY
WALL
CORNER BEAD, TYP.
3 5/8" METAL STUD
LOCATED AT ABUTTING WALL
AND ATTACHED THRU GYPSUM
WALLBOARD TO STUD OF
ABUTTING WALL
5/8" GYPSUM WALLBOARD -
NUMBER OF LAYERS PER
PARTITION TYPE
GYPSUM
WALLBOARD
3 5/8" METAL STUD
LOCATED AT ABUTTING WALL
AND ATTACHED THRU GYPSUM
WALLBOARD TO STUD OF
ABUTTING WALL
TAPE & JOINT COMPOUND
TWO HOUR FIRE & SMOKE PARTITION
TWO HOUR FIRE PARTITION
TWO HOUR SHAFT PARTITION
ONE HOUR FIRE & SMOKE PARTITION
ONE HOUR FIRE PARTITION
NON RATED PARTITION
CONTINUE 2" WIDE x 22 GA MTL
STRAP FOR TOP ATTACHMENT
OF GYP BD
WHERE GYP BD IS CONCURRENT
WITH DECK FLUTE RECESS,
EXTEND UP INTO RECESS AS
SHOWN
EXTEND ONE LAYER UP INTO
FLUTE RECESS AND SEAL
22 GA MTL TRACK WITH 2"
FLANGES - ATTACH TO STEEL
DECK AT 12" O.C. MAX.
WHEN PARTITION IS ALIGNED AT
DECK FLUTE RECESS - PROVIDE
CONTINUOUS 10" 22 GA MTL PLATE
AT DECK FLUTE RECESS THAT IS
CONTIGUOUS WITH PARTITION -
ATTACH METAL PLATE TO DECK
WITH POWER DRIVEN FASTENERS
SEAL ONE SIDE OF PARTITION
AGAINST PASSAGE OF SMOKE
CONTINUE 22 GA 2 1/2" x 2 1/2"
MTL ANGLE WITH 2 1/2" WIDE
PIECE OF GYP BD USED FOR THE
WALL - ATTACH PLATE OR STEEL
DECK AT 12" O.C. MAX.
22 GA MTL TRACK WITH 2"
FLANGES - ATTACH TO PLATE OR
STEEL DECK AT 12" O.C. MAX.
CONTINUE 2" WIDE x 22 GA MTL
STRAP, ATTACH GYP BD TO
STRAP AT 8" O.C. MAX.
CONTINUE 10" WIDE x 22 GA MTL
PLATE AT EACH DECK FLUTE.
RECESS CONTIGUOUS WITH
PARTITION - ATTACH TO DECK
WITH POWER DRIVEN
FASTENERS AT 12" O.C. MAX.
FILL DECK FLUTE RECESS WITH
SAFING INSULATION - CAP ENDS
OF INSULATION WITH 1/2" THICK
FIRE/SMOKE RESISTANT FILL
MATERIAL WHERE PARTITION
TERMINATES OR CHANGES
DIRECTION
CONTINUE 10" WIDE x 22 GA MTL
PLATE AT EACH DECK FLUTE.,
RECESS CONTIGUOUS WITH
PARTITION - ATTACH TO DECK
WITH POWER DRIVEN
FASTENERS AT 12" O.C. MAX.
CAP ENDS OF INSULATION WITH
1" THICK FIRE/SMOKE
RESISTANT FILL MATERIAL
WHERE PARTITION TERMINATES
OR CHANGES DIRECTION
CONT. 22 GA 2 1/2" x 2 1/2" MTL
ANGLE WITH 2 1/2" WIDE PIECE
OF GYP BD USED FOR THE
WALL - ATTACH PLATE OR STEEL
DECK AT 12" O.C. MAX.
FILL DECK FLUTE RECESS WITH
SAFING INSULATION
FILL DECK FLUTE
RECESS WITH
SAFING INSULATION
1/2" THICK FIRE/SMOKE
RESISTANT FILL MATERIAL.
FILL DECK FLUTE RECESS
(BOTH SIDES)
POWER DRIVEN STEEL
FASTENERS AT 12" O.C. MAX.
(TYPICAL FOR ANGLES BOTH
SIDES)
ONE HOUR RATED
(UL-HW-D-0001)
NON-RATED OR
SMOKE RESISTANT
CONT. 2" WIDE x 22 GA MTL
STRAP, ATTACH GYP BD TO
STRAP AT 8" O.C. MAX.
22 GA MTL TRACK WITH 2"
FLANGES - ATTACH TO PLATE OR
STEEL DECK AT 12" O.C. MAX.
TWO HOUR RATED
(UL-HW-D-0002)
CONTINUE 10" WIDE x 22 GA MTL
PLATE AT EACH DECK FLUTE.
RECESS CONTIGUOUS WITH
PARTITION - ATTACH TO DECK
WITH POWER DRIVEN
FASTENERS AT 12" O.C. MAX.
CAP ENDS OF INSULATION WITH
1" THICK FIRE/SMOKE
RESISTANT FILL MATERIAL
WHERE PARTITION TERMINATES
OR CHANGES DIRECTION
ATTACH PLATE OR STEEL DECK
AT 12" O.C. MAX.
CMU PARTITION - DEPENDING ON
HOW COURSING INTERSECTS
THE STEEL DECK, THE TOP
COURSE OF BLOCK MAY BE
REQUIRED TO BE CUT
FILL DECK FLUTE RECESS
W/ SAFING INSULATION
CONT. 22 GA 2 1/2" x 2 1/2" MTL
ANGLE WITH 2 1/2" x 2 1/2" PIECE
OF GYP BD USED FOR THE WALL
POWER DRIVEN STEEL
FASTENERS AT 12" O.C. MAX.
(TYPICAL FOR ANGLES BOTH
SIDES)
POWER DRIVEN STEEL
FASTENERS AT 12" O.C. MAX.
(TYPICAL FOR ANGLES BOTH
SIDES)
1" THICK FIRE/SMOKE
RESISTANT FILL MATERIAL.
FILL DECK FLUTE RECESS
(BOTH SIDES)
1" THICK FIRE/SMOKE
RESISTANT FILL MATERIAL
TWO HOUR RATED
(UL-HW-D-0009)
CONT. 22 GA 2 1/2" x 2 1/2" MTL
ANGLE WITH 2 1/2" WIDE PIECE
OF GYP BD USED FOR THE WALL
DOUBLE 20 GA.
METAL STUDS
22 GA. METAL
TRACK
1" x 22GA. METAL
STRAP PLATES
AT 3'-6" O.C.
EACH SIDE
CLIP ANGLE -
18 GA. x 1 1/2" x 11/2"
x 3" FOR 3 5/8"
STUDS AND 5" FOR
6" STUDS EACH SIDE
E22 GA. METAL
SILL TRACK BELOW
20 GA.
METAL STUDS
22 GA.
METAL TRACK
DOUBLE 20 GA.
METAL STUDS
AT BOTH
JAMBS
22 GA. METAL
SILL TRACK
BELOW
1" x 22 GA. METAL
STRAP PLATES AT 3'-
6" O.C. EA. SIDE
22 GA. METAL
TRACK
CLIP ANGLE -
18 GA. x 1 1/2" x
1 1/2" x 3" FOR
3 5/8" STUDS
AND 5" FOR 6"
STUDS EACH
SIDE
22 GA. METAL
TRACK
CLIP ANGLE -
18 GA. x 1 1/2" x 1 1/2"
x 3" FOR 3 5/8"
STUDS AND 5" FOR
6" STUDS EACH SIDE
22 GA. METAL
TRACK
CLIP ANGLE -
18 GA. x 1 1/2" x 1 1/2"
x 3" FOR 3 5/8" STUDS
AND 5" FOR 6" STUDS
EACH SIDE
DOUBLE 18 GA.
3 5/8" OR 6"
METAL STUDS
22 GA. METAL
TRACK
CLIP ANGLE -
18 GA. x 1 1/2" x
1 1/2" x 3" FOR
3 5/8" STUDS
AND 5" FOR 6"
STUDS EACH
SIDE
06
04 03 01 02
05
TYPICAL FRAMING DETAILS
2 3/4"
C.J.
GYP. BD. SUSPENDED
CEILING SYSTEM
24'-0"
MAX
24'-0"
MAX
GYPSUM BOARD
CEILING
INTERIOR PARTITION
NON-EXPOSED EDGE
PARTITION INTERSECTION/
CHANGE IN CONSTRUCTION
LINE OF
PARTITION
SEALANT
AND BACKER
ROD
L-BEAD
SOUND
ATTENUATION
BLANKET
COMPRESSED
TO FILL
OPENING AT
SOUND RATED
PARTITION
PARTITION
1/4"
BACKER ROD &
SEALANT
"LC" BEAD
PARTITION
LINE OF
PARTITION
3/8"
NON-RATED DETAILS
11/16"
1/2" MAX
5/8"
METAL
TRIM
CONTROL
JOINTS EA
SIDE
METAL
STUDS W/
5/8" TYPE
"X" GYP.
BD. EA.
SIDE
2 LAYERS OF
5/8" GYP. BD.
SOUND
ATTENUATION
BLANKET,
WHERE
PARTITION
CALLS FOR
INSULATION
1 HR. RATED GYP. CONTROL JOINT
REF PARTITION TYPE FOR INSULATION
METAL TRIM
CONTROL
JOINTS EA
SIDE
METAL
STUDS W/ 2
LAYERS 5/8"
TYPE "X"
GYP. BD. EA.
SIDE
5/8"
1/2" MAX
2 HR. RATED GYP. CONTROL JOINT
REF PARTITION TYPE FOR INSULATION
RATED DETAILS
TELEPHONE OR
ELECTRICAL BOXES
1/2" OR 5/8" TYPE "X"
GYP. BD. AS REQUIRED
FOR TWO HOUR RATED
FIRE OR SMOKE WALL
TYPICAL STEEL STUD
EACH 16 SQ. IN. MAX.
TOTAL OPENING
100 SQ. IN./100 SQ. FT.
(PER) UL
2'-0" MIN.
SEAL BOXES WITH
JOINT COMPOUND
A = MTL STUD; DECK TO DECK; (1) LAYER GYP BD EA SIDE
B = MTL STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE
C = MTL STUD CHASE WALL; DECK TO DECK;
(1) LAYER GYP BD EA SIDE
D = MTL STUD; PARTIAL HEIGHT; 6" ABOVE CEILING;
(1) LAYER GYP BD EA SIDE
E = MTL STUD; PARTIAL HEIGHT; TO CEILING;
(1) LAYER GYP BD EA SIDE
F = MTL STUD FURRING; DECK TO DECK;
(1) LAYER GP BD ON FINISH FACE
G = MTL STUD FURRING; PARTIAL HEIGHT;
6" ABOVE CEILING; (1) LAYER GYP BD ON FINISH FACE
L = MTL STUD; DECK TO DECK;
(1) LAYER LEAD LINED GYP BD ON FINISH SIDE 'A';
(1) LAYER GYP BD ON FINISH SIDE 'B'
M = CMU; DECK TO DECK
N = CMU; PARTIAL HEIGHT; 6" ABOVE CEILING
P = MTL STUD W/ STL ANGLE POSTS AT 4'-0" OC;
PARTIAL HEIGHT; BELOW CEILING;
(1) LAYER GYP BD EA SIDE
S = MTL C-H STUD SHAFT WALL; DECK TO DECK;
(1) LAYER GYP BD ON ROOM FINISH SIDE;
(1) LAYER 1" SHAFT WALL LINER ON SHAFT SIDE
T = MTL C-H STUD SHAFT WALL; DECK TO DECK;
(2) LAYERS GYP BD ON ROOM FINISH SIDE;
(1) LAYER 1" SHAFTWALL LINER ON SHAFT SIDE
U = UNKNOWN PARTITION COMPOSITION
W = WD STUD; DECK TO DECK; (1) LAYER GYP BD EA
SIDE
X = WD STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE
Y = WD STUD; PARTIAL HEIGHT; 6" ABOVE CEILING;
(1) LAYER GYP BD EA SIDE
Z = WD STUD; PARTIAL HEIGHT; TO CEILING;
(1) LAYER GYP BD EA SIDE
PARTITION TYPE
PARTITION TYPE
NOMINAL WIDTH
FIRE OR SMOKE RATING
SEE NOMINAL WIDTH SCHEDULE BELOW
SEE PARTITION GRAPHIC LEGEND BELOW
DESIGNATION AS NOTED ON
PARTITION TYPE BELOW
PARTITION DESIGNATOR
MTL. STUD
GYP. BD.
DETAIL "A1"
CONT. 20 GA.
4" WIDE MTL.
BACK-UP PLATE
DETAIL "A2"
CONT. 18 GA.
8" WIDE MTL.
BACK-UP PLATE
3 5/8" MIN.
(DEEPER IF
REQUIRED)
14 GA. STL RUNNER
TRACK -- CLIP FLANGES
TO FIT OVER STUDS
MTL WALL STUDS
2x8 (MIN.) WD.
BLOCKING
BETWEEN
STUDS
(DEEPER IF
REQUIRED) CONT. 20 GA.
6" WIDE MTL
BACK-UP PLATE
(4) #2 WOOD SCREWS
EACH END
(3) 1/4"x3" WOOD
SCREWS EACH END
REFER
TYPICAL
MOUNTING
HEIGHTS
REFER
TYPICAL
MOUNTING
HEIGHTS
REFER
TYPICAL
MOUNTING
HEIGHTS
MIN. 18 GA. MTL
STUDS
DETAILS "A1 & A2"
(SECTION VIEW)
DETAIL "B"
(ISOMETRIC VIEW)
DETAILS "C1 & C2"
(ISOMETRIC VIEW)
C1: WOOD BLOCKING ONLY
C2: WOOD BLOCKING W/ METAL BACK-UP PLATE
11
METAL
STUD
CMU
7/8"
1 5/8"
2 1/2"
3 5/8"
4"
6"
N/A
11 5/8"
3 5/8"
5 5/8"
7 5/8"
9 5/8"
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
WOOD STUD
N/A
N/A
N/A
3 1/2"
5 1/2"
N/A
7 1/4"
N/A
N/A
N/A
N/A
N/A
'U' WIDTH
RANGE
0 - .99"
11" - 11.99"
3" - 3.99"
5" - 5.99"
7" - 7.99"
9" - 9.99"
1" - 1.99"
2" - 2.99"
4" - 4.99"
6" - 6.99"
8" - 8.99"
10" - 10.99"
N/A
#
12
10
9
8
7
6
5
4
3
2
1
N/A
N/A 0 N/A
12" - 12.99"
NOMINAL WIDTH SCHEDULE
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
10/12/2016
6:08:43 PM
PARTITION TYPES,
DETAILS, AND
STANDARDS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A020
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
TYPE
CONSTRUCTION DATA FIRE PARTITIONS
STC RATING
FRAMING / CORE SIZE
OVERALL PARTITION
WIDTH RATING UL DESIGNATION
A - MTL STUD; DECK TO DECK; (1) LAYER FINISH MATERIAL EA SIDE
A2a 2 1/2" 3 3/4" 0 HR
A4a 3 5/8" 4 7/8" 0 HR
A4b 3 5/8" 5 3/4" 0 HR
A6a 6" 7 1/4" 0 HR
F - MTL STUD FURRING; DECK TO DECK; (1) LAYER GYP BD ON FINISH FACE
F1a 7/8" 1 1/2" 0 HR
F2a 1 5/8" 2 1/4" 0 HR
F3a 2 1/2" 3 1/8" 0 HR
F4a 3 5/8" 4 1/4" 0 HR
W - WOOD FURRING STRIPS; DECK TO DECK; (1) LAYER FINISH MATERIAL ON FINISH FACE
W1a 3/4" 1 1/2" 0 HR
NOTES - PARTITION TYPE
1. CONSTRUCTION OF FIRE RATED PARTITIONS SHALL BE IN ACCORDANCE WITH THE TESTING DESIGN DESIGNATED. ARCHITECTURAL
DETAILS MAY NOT INDICATE EVERY REQUIRED COMPONENT OF TESTED ASSEMBLY.
2. PROVIDE CONTROL JOINTS IN ALL GYPSUM WALLBOARD PARTITIONS AT 30'-0" OC MAXIMUM OR AS INDICATED ON FLOOR PLANS.
3. ONE SIDE OF GYPSUM WALLBOARD MAY BE INSTALLED WHEN UNUSED SPACE (IE, UNDER STAIR) OR UNFINISHED TENANT SPACE
EXISTS ON ONE SIDE, EXCEPT WHERE REQUIRED FOR FIRE RATING.
4. ALL STUD/ SPACING SHALL BE 16" OC UNLESS OTHERWISE NOTED.
5. PARTITION SYMBOL INDICATIONS ON FLOOR PLANS DESIGNATE THE ENTIRE LENGTH OF WALL INDICATED UNLESS INTERRUPTED BY
ANOTHER SYMBOL.
6. UTILIZE EXTENDED TRACKS WITH SLOTTED HOLES AT TOPS OF PARTITIONS WHEREVER ATTACHING TO STRUCTURE ABOVE TO
ALLOW FOR DEFLECTION.
7. PROVIDE FIRE BLOCKING FOR ALL PARTITIONS OPEN TO CEILING CAVITY. UTILIZE GYPSUM WALLBOARD WITH STEEL FRAMING
WHERE SPACE IS TOO WIDE FOR SOLID STEEL OR INSULATION TYPE FIRE BLOCKING, UNLESS OTHERWISE INDICATED. PROVIDE
IMPALING CLIPS WHERE REQUIRED TO SUPPORT INSULATION FIRE BLOCKING.
8. THE PARTITION TYPE SCHEDULE INCLUDES ONLY NEW PARTITIONS WITHIN THE SCOPE OF WORK.
9. SUBSTITUTE MOISTURE RESISTANT BOARD (PURPLE BOARD) FOR WET LOCATIONS (TOILETS, LOCKER ROOMS) OR WHERE
SCHEDULED TO RECEIVE CERAMIC TILE OR STONE. FOR OTHER WET APPLICATIONS SUCH AS SHOWERS, USE CEMENTITIOUS TILE
BACKER BOARDS.
10. ALL GYPSUM BOARDS SHALL BE 5/8" THICK AND HELD OFF 1/2" FROM FLOOR SURFACE, UNO.
11. PROVIDE CONTINUOUS SEALANT UNDER METAL TRACKS AND AT PERIMETER OF GYPSUM BOARD PANELS AT SMOKE RATED, STC
RATED OR FIRE RATED ASSEMBLIES.
12. PROVIDE MARKINGS ABOVE SUSPENDED CEILINGS AND IN CONCEALED SPACES TO IDENTIFY FIRE RATED PARTITIONS. SUCH
SIGNAGE SHALL BE 1" HIGH (MIN) LETTERS AND SHALL STATE "FIRE RATED ASSEMBLY" AT HORIZONTAL INTERVALS OF 8 FT.
13. METAL STUD PARTITIONS SCHEDULED TO SUPPORT WALL MOUNTED CASEWORK OR EQUIPMENT SHALL HAVE 33 MIL (20 GA) MIN
STUDS FOR THE ENTIRE LENGTH OF THE CASEWORK.
14. PROVIDE WOOD OR METAL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING CASEWORK, GRAB BARS, SHELVING,
HANDRAILS, TOILET PARTITIONS, ETC. REF TYP DETAILS FOR BLOCKING.
15. PROVIDE DOUBLED 33 MIL (20 GA) MIN STUDS AROUND ALL DOOR, WINDOW OR CASED OPENINGS.
16. ALL GYPSUM BOARD FOR FIRE RATED PARTITIONS SHALL BE "TYPE X", UNLESS OTHERWISE REQUIRED BY RATING DESIGN
DESIGNATION.
17. REF. ENLARGED DETAILS AT TOPS OF FIRE RATED PARTITION HEAD DETAILS.
18. ORIENTATION OF SHAFT WALL ASSEMBLY MAY VARY FROM THAT SHOWN ON DRAWINGS AND MAY BE DETERMINED ON SITE AS
REQUIRED AFTER CONSIDERATION IS MADE FOR STRUCTURAL OBSTRUCTIONS THAT PREVENT THE PROPER FASTENING OF
GYPSUM BOARD.
19. WHERE INSULATION IS INDICATED, PROVIDE SOUND ATTENUATION BLANKETS (THERMAFIBER OR EQUAL). THERMAL FIBERGLASS
INSULATION NOT ACCEPTABLE.
20. STC RATINGS ARE SHOWN FOR KNOWN TEST ASSEMBLIES FOR THE STUD SIZE INDICATED. FOR OTHER STUD SIZES COMPLY WITH
REQUIREMENTS OF CLOSEST SIMILAR ASSEMBLY.
21. ALL PENETRATIONS IN FULL HEIGHT PARTITIONS SHALL BE SMOKE RESISTIVE AND FIRESTOPPED REGARDLESS OF THE PARTITION
RATING.
22. PARTIAL-HEIGHT INSULATED PARTITIONS SHALL RECEIVE 1-LAYER OF CONTINUOUS 3" SOUND ATTENUATION BLANKETS ON TOP OF
CEILING, EXTENDING 4'-0" FROM EACH SIDE OF PARTITION FACE, UNLESS OTHERWISE INDICATED.
23. FIRE-RATED PARTITIONS SHALL RECEIVE LISTED AND LABELED FIRE-RATED SEALANT SYSTEM (EACH SIDE) AT CONNECTION WITH
UNDERSIDE OF STRUCTURAL DECK OR FIRE-PROOFED CEILING AND WITH FLOOR STRUCTURE.
24. ALL INTERIOR PARTITIONS SHALL RECEIVE BASE FINISH AS SCHEDULED, UNO.
25. ALL FULL-HEIGHT PARTITIONS TO RECEIVE CONTINUOUS SEALANT AT GAP BETWEEN GYP BD & STRUCTURE ABOVE, UNO.
26. CHASE WALL PARTITIONS SHALL RECEIVE 2 1/2" MTL STUD BRACES OR GYP GUSSET CONNECTING STUDS SPACED VERTICALLY 4'-0"
OC, UNO.
27. PARTIAL HEIGHT MTL STUD PARTITIONS AT OR ABOVE CEILING HEIGHT SHALL RECEIVE CONTINUOUS STUD TOP TRACK W/ 2 1/2" 33
MIL (20 GA) MTL STUD BRACES AT 4'-0" OC MAX, ALTERNATING SIDES, UNO.
28. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE 'L' BEAD AT GYP BD CEILING CONNECTION, UNO.
29. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE PARTITION CLIP FOR ATTACHMENT W/ DIAGONAL BRACING ABOVE
CEILING, UNO. PROVIDE DIAGONAL BRACING FOR ACOUSTICAL CEILING PANELS.
30. ALL LEAD-LINED GYP BD TO EXTEND 7'-0" AFF, UNO.
31. ALL FULL-HEIGHT MASONRY PARTITIONS TO RECEIVE COMPRESSIBLE FILLER AT CONNECTION WITH STRUCTURE ABOVE, UNO.
32. ALL MASONRY PARTITIONS TO RECEIVE HORIZONTAL MASONRY REINFORCEMENT AT 16" OC VERTICALLY, UNO.
33. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE 3"x3"x5/16" STEEL ANGLE POSTS WELDED TO 8"x3 1/2"x3/8" STEEL
FLOOR PLATE AND 3"x3"x5/16" TOP ANGLE. PROVIDE 1" DIA HOLE IN STEEL ANGLE POSTS FOR CONDUIT. ATTACH STEEL FLOOR
PLATE TO FLOOR STRUCTURE W/ (3) 3/8" DIA ANCHOR BOLTS.
34. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE GYP BD CAP & WOOD BLOCKING ATTACHED TO STEEL TOP
ANGLE, UNLESS OTHER TRIM IS INDICATED.
35. ALL SHAFT WALL PARTITIONS SHALL RECEIVE J-STUD RUNNER (24 GA MIN) ATTACHED TO FLOOR STRUCTURE AND C-H MTL STUDS
SPACED @ 24" OC.
36. WOOD STUD PARTITIONS SUPPORTED ON FLOORS W/ GYPSUM TOPPING SHALL HAVE DOUBLE SILL PLATES.
37. SECURE SILL PLATES ON WOOD I-JOISTS OR TRUSS-SUPPORTED FLOORS THROUGH SUBFLOOR AND INTO STRUCTURAL SUPPORT.
SCHEDULE - PARTITION TYPE
STANDARDS - PARTITION TYPE DESIGNATION DIAGRAMS
LEGEND - PARTITION TYPE DESIGNATIONS
STANDARDS - PARTITION HEAD DETAILS
STANDARDS - TYPICAL NON-LOAD-BEARING PARTITION FRAMING AND DETAILS
STANDARDS - RATED WALL INTERSECTIONS
STANDARDS - CONTROL JOINT DETAILS
STANDARDS - ADJACENT ELECTRICAL BOXES
STANDARDS -
BLOCKING AND MOUNTING DIAGRAMS
SEALANT
1 08/25/2016 Revision 1
10/17/2016
06/21/17