HomeMy WebLinkAboutB16-0266_A404_1498075740.pdfREF
OFFICE 1
132
OFFICE 3
130
OFFICE 4
129
RECEPTION
128
132 130
129
128
A4a
F2a
F2a
A4a
A4a
A4a
A4a
F2a
EQ
ALIGN
F2aF2a
9'-6 3/4" 4 1/4"
A4a
A4a
A4a
F2a
F2a
4'-0"
5'-0"
EQ
OFFICE 2
131
128A
131
EQ
7'-10 3/4"
2'-8"
9'-0" CLR 9'-10"
CLR
3'-6" MIN ALIGN
EMPLOYEE
BREAK
ROOM
136
M EMPLOYEE
LOCKER
ROOM
138
9.18
4'-1"
4'-1"
9.18
135
137
138
A404
2D
3D
A404
5D
6D
A404
3.2
3.2
A4a
F2a
F2a
A4a
F2a
F2aF2a
A4a
F2a
10'-5 1/2"
2'-8"
MIN
1'-6" MIN 5'-0" MIN CLR
A4a
2'-8"
5'-0" MIN CLR
1'-6" MIN
17'-11 3/4" 4 3/4"
STORAGE
135
W EMPLOYEE
LOCKER
ROOM
137
3E 2 1/2" A4a A4a F2a
F2aF2a
A4a
A4a
F4aF4a
A4a
F2aF2a
F2a
F2a
REF 4'-6" R.O.
4'-0" MIN CLR
MIN CLR
5'-0"
5'-0" MIN CLR
5'-0" MIN CLR 5'-0" MIN CLR
3'-4" MIN
1'-8" 5'-0" 5'-0"
MIN
1'-3"
MIN
2'-6"
MIN
1'-3"
A6a
MIN
1'-3"
MIN
2'-6"
MIN
1'-3"
3'-4" MIN 1'-8"
SCREEN
2'-0" PRIVACY
20" MIN A604
2D SIM
A604
2D SIM
136
VEND VEND
4E
OFFICE 1
132
OFFICE 3
130
RECEPTION
128
OFFICE 4
129
C ACT
8' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
OFFICE 2
131
EMPLOYEE
BREAK
ROOM
136
M EMPLOYEE
LOCKER
ROOM
138
C GYP
6' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
C GYP
6' - 0" A.F.F.
C ACT
8' - 0" A.F.F.
C GYP
11' - 7 3/4" A.F.F.
C ACT
8' - 0" A.F.F.
STORAGE
135
W EMPLOYEE
LOCKER
ROOM
137
C ACT
8' - 0" A.F.F.
COORDINATE WITH LOCKERS BELOW
8'-0"
1'-3"
1'-6"
B CTB-003
W PNT-008 W CT-004
2E
A604
SIM
PROVIDE ALL CURTAINS,
RODS AND HOOKS TO
CLOSE OPENING
3A
A604
B CTB-003
W PNT-008
W CTB-004
W PNT-008
W CT-004
REMOVABLE PANEL, ENSURE
KNEE AND TOE CLEARANCE
MEETS ADA STANDARDS, REF
DETAIL 3B/A604
3'-2"
FINISH TOP EDGE OF
TILE WITH ALUMINUM
SCHLUTER SCHIENE
STRIP
SSM-01
3A
A604
B
W
W W
W
REMOVABLE PANEL, ENSURE
KNEE AND TOE CLEARANCE
MEETS ADA STANDARDS, REF
DETAIL 3B/A604
3'-2"
FINISH TOP EDGE OF
TILE WITH ALUMINUM
SCHLUTER SCHIENE
STRIP
B
W W
2E
A604
SIM
PROVIDE ALL CURTAINS,
RODS AND HOOKS TO
CLOSE OPENING
WATER
BOX
OUTLET
FOR REF.
VALENCE TO HIDE
UNDERCABINET
LIGHTING, TYP.
1'-6"
EQ VIF EQ
3'-0" 2'-6"
2'-6"
4A
A604
5A
A604
6A
A604
2'-10" 1'-8" 3'-0"
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
10/12/2016
6:12:12 PM
ENLARGED PLANS -
BACK OF HOUSE
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A404
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0" DRAWING REF: A111
2AENLARGED FLOOR PLAN - BACK OF HOUSE
SCALE: 1/4" = 1'-0" DRAWING REF: A111
4AENLARGED FLOOR PLAN - EMPLOYEE BREAKROOM & LOCKER ROOMS
SCALE: 1/4" = 1'-0" DRAWING REF: A121
2BENLARGED REFLECTED CEILING PLAN - BACK OF HOUSE
SCALE:
1/4" = 1'-0" DRAWING REF: A121
4BENLARGED REFLECTED CEILING PLAN - EMPLOYEE BREAKROOM AND LOCKER ROOMS
KEYNOTES
3.2 NEW CONCRETE SLAB. SEE STRUCTURAL DRAWINGS.
9.18 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS,
CONTROLS, CURTAIN & ROD.
SCALE: 1/4" = 1'-0" DRAWING REF: A404
2DELEVATION - M EMPLOYEE LOCKER ROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A404
3DELEVATION - M EMPLOYEE LOCKER ROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A404
5DELEVATION - W EMPLOYEE LOCKER ROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A404
6DELEVATION - W EMPLOYEE LOCKER ROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A404
3EELEVATION - EMPLOYEE BREAKROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A111
4EELEVATION - EMPLOYEE BREAKROOM
1 08/25/2016 Revision 1
10/17/2016
06/21/17