HomeMy WebLinkAboutB16-0266_A430_1478900134.pdfREF
KA
204
A430
2D
3D
4D
5D
A430
2C
3C
4C
6C
MIN
1'-6"
8.1
8.6
8.5
8.7
27.1
23.3
23.2
8.8
8.10
23.1
26.3
26.6
26.6
22.6
22.5
22.4
22.7
12.4
22.8
8.17
8.18
10.1
GR-E
GR-A
A4a
A4a
F2a
5'-0". 2'-5 1/2"
MIN
1'-6"
KA
204
2.25 2.14
2.22
2.15
2.30
2.9
2.17
2.16
2.30
2.71
2.19 2.4
2.43
2.7
2.1
2.5
2.3
2.4
2.43
2.73
2.74 2.70
2.70
2.74
2.74
KA
204
F CPT-100
C PNT-001
C PNT-001
W PNT-003
B VB-001
W WD-001
F CT-001
W VWC-200
B CTB-001 F CT-001
B CTB-001
ALIGN
T-01
T-02
9.2
9.5
KA
204
LTG-100
LTG-101
CSG-100
CSG-101
BED-100
BED-101
BED-101.1
CSG-100
UPH-100 LTG-102
WTR-101
EQU-100
CSG-102
UPH-102 LTG-103
BED-102
UPH-102.1
ART-101
CSG-103
TA-2
TA-3
TA-6
PF-1
PF-2 PF-3
UPH-102.2
UPH-102.3
BED-106
UPH-100.1
ART-100
MIR-100
ART-102
CSG-107
WTR-100
TA-8
TA-5
PF-7
B VB-001
W PNT-003
W WD-001 W PNT-003
B VB-001
W PNT-003
T PNT-002 B VB-001 B VB-001
W PNT-003
B CTB-001
W PNT-003
W WD-002
B CTB-001
W VWC-200
B CTB-001
W VWC-200
W SRD-001
B CTB-001
W VWC-200
W SRD-001
B CTB-001
W VWC-200
W SRD-001
T PNT-002
KA
204
C EXIST
8' - 0" A.F.F.
C EXIST
7' - 4" A.F.F.
C GYP
7' - 0" A.F.F.
C EXIST
7' - 0" A.F.F.
MATCH ADJACENT
C GYP
7' - 0" A.F.F.
2.77
2.77
2.77
9.6
9.6
9.6
26.7
26.7
26.7
26.5
+ -
+ -
+ -
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
11:16:42 AM
ENLARGED
ACCESSIBLE
GUESTROOM PLANS -
KA (ROOM 204)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
A430
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0" DRAWING REF: A112
3ACONSTRUCTION - KA (ROOM 204)
KEYNOTES
2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION.
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE.
2.9 REMOVE TUB AND SURROUND.
2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER.
2.22 REMOVE WINDOW TREATMENTS.
2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER.
2.30 REMOVE WALL PARTITION TO EXTENT SHOWN.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
2.70 REMOVE GRAB BARS.
2.71 REMOVE WC.
2.73 REMOVE SHELF.
2.74 REMOVE AND SALVAGE GRAB BAR TO BE REINSTALLED.
2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT
BULB.
8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR
ACOUSTIC PROTECTION.
8.5 PROVIDE SECURITY LATCH.
8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR
CLOSER.
8.7 PROVIDE COVER FOR DOOR VIEWER.
8.8 PROVIDE WINDOW VALANCE.
8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS.
8.17 PROVIDE LOOP TYPE CURTAIN PULLS 15-48" AFF.
8.18 PROVIDE SECURITY LATCH AT 48" AFF.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH.
9.5 PROVIDE TUB SURROUND.
9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND
SPACKLE TO SMOOTH FINISH AND PAINT.
10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED.
12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH
HORIZONTAL PIECE TO SIZE.
22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER
AND OVERFLOW DRAIN.
22.5 PROVIDE SINK AND FAUCET.
22.6 PROVIDE WC.
22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION.
22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND
DIVERTER.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.2 PROVIDE AMANA PTAC AIR UNIT.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.3 PROVIDE FACEPLATE AT PHONE.
26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
26.7 PROVIDE LED LIGHT TO REPLACE EXISTING.
27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE.
SCALE: 1/4" = 1'-0" DRAWING REF: D112
2ADEMO PLAN - KA (ROOM 204)
SCALE: 1/4" = 1'-0" 4AFINISH PLAN - KA (ROOM 204)
SCALE: 1/4" = 1'-0" 5AFF&E PLAN - KA (ROOM 204)
SCALE: 1/4" = 1'-0" DRAWING REF: A430
2CELEVATION
SCALE: 1/4" = 1'-0"
DRAWING REF: A4303CELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A430 4CELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A430 6CELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A430
2DBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4303DBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4304DBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A430
5DBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A122 6ARCP - KA (ROOM 204)
7/11/16
P.O. BOX 400, RICHMOND,
VA 23218-0400
®
08/16/16