HomeMy WebLinkAboutB16-0266_A431_1478902418.pdfKA
203
8.10
23.2
26.3
10.1
23.3
12.4
8.8
26.6
26.6
8.1
4.1
8.7
A431
2B
3B
5B
6B
A431
2C
3C
4C
5C GR-A
MIN
1'-6"
8.6
8.18
27.1
8.17
22.6
22.8
22.4
22.7
MIN
4'-11"
2'-8" 3'-0" 3'-5 1/2"
1'-4"
F4a
F4a
A4a
GR-E
MIN
1'-0"
22.5
23.1
8.16
KA
203
2.3
2.15
2.16
2.17
2.14
2.25
2.9
2.5
2.22
2.19
2.30
2.1
2.7 2.3
2.4
2.43
2.4
2.43
2.70
2.702.70
2.70
2.70
2.73
2.71
KA
203
TA-7
TA-1
TA-21
TA-3
TA-23 TA-1
TA-6
WTR-100 &
WTR-101
LTG-100
CL3'-6"
EQU-101.1
LTG-102ART-100
CSG-100
UPH-100
UPH-100.1
CL
CL
2'-2" 1'-10 3/4"
ART-102 ART-101
LTG-101
CSG-100
CSG-101
BED-100
BED-101
BED-101.1
BED-102
BED-106
CL
CL 4'-5 1/4" 4'-0"
TA-17
TA-2
TA-19
CSG-120
KA
203
W
SRD-001
ALIGN
T-01
T-02
F CPT-100
C PNT-001
W PNT-003
B VB-001
W WD-001
F CT-001
B CTB-001
C PNT-001
F CT-001
W VWC-200
B CTB-001
9.2
KA
203
C EXIST
8' - 0" A.F.F.
C EXIST
7' - 0" A.F.F.
C EXIST
7' - 4" A.F.F.
2.77
9.6
2.77
9.6
26.7
26.7
26.7
MATCH
ADJACENT
26.5
+ -
+ -
2.77
9.6
W WD-001
B CTB-001
T PNT-002
B VB-001
ART-102
LTG-101
WTR-100 &
WTR-101
5'-0"
4'-6"
B VB-001
W PNT-003
WTR-100 &
WTR-101
WTR-100VAL
B CTB-001
W PNT-003
B VB-001
W PNT-003
CL4'-6"
CL
3'-6"
ART-100
B VB-001
W PNT-003
T PNT-002 CL
5'-0"
CL
CL
2'-2" 1'-10 3/4"
ART-101
ART-102
B CTB-001
W VWC-200
B CTB-001
W VWC-200 W SRD-001
WRAP EXPOSED PIPES
B CTB-001
W VWC-200 W SRD-001
B CTB-001
W VWC-200
W SRD-001 T PNT-002
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
8/29/2016
4:10:19 PM
ENLARGED
ACCESSIBLE
GUESTROOM PLANS -
KA (ROOM 203)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A431
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION.
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE.
2.9 REMOVE TUB AND SURROUND.
2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER.
2.22 REMOVE WINDOW TREATMENTS.
2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER.
2.30 REMOVE WALL PARTITION TO EXTENT SHOWN.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
2.70 REMOVE GRAB BARS.
2.71 REMOVE WC.
2.73 REMOVE SHELF.
2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT
BULB.
4.1 PROVIDE STONE THRESHOLD AT DOOR.
8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR
ACOUSTIC PROTECTION.
8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD
DOOR CLOSER.
8.7 PROVIDE COVER FOR DOOR VIEWER.
8.8 PROVIDE WINDOW VALANCE.
8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS.
8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS.
8.17 PROVIDE LOOP TYPE CURTAIN PULLS 15-48" AFF.
8.18 PROVIDE SECURITY LATCH AT 48" AFF.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT
FINISH.
9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND
SPACKLE TO SMOOTH FINISH AND PAINT.
10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED.
12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH
HORIZONTAL PIECE TO SIZE.
22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER
AND OVERFLOW DRAIN.
22.5 PROVIDE SINK AND FAUCET.
22.6 PROVIDE WC.
22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION.
22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND
DIVERTER.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.2 PROVIDE AMANA PTAC AIR UNIT.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.3 PROVIDE FACEPLATE AT PHONE.
26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
26.7 PROVIDE LED LIGHT TO REPLACE EXISTING.
27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE.
SCALE: 1/4" = 1'-0" DRAWING REF: A112
3ACONSTRUCTION - KA (ROOM 203)
SCALE: 1/4" = 1'-0" DRAWING REF: D112
2ADEMO PLAN - KA (ROOM 203)
SCALE: 1/4" = 1'-0" 5AFF&E PLAN - KA (ROOM 203)
SCALE: 1/4" = 1'-0"
4AFINISH PLAN - KA (ROOM 203)
SCALE: 1/4" = 1'-0" DRAWING REF: A122
6ARCP - KA (ROOM 203)
SCALE: 1/4" = 1'-0" DRAWING REF: A431
3BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4315BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4316BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A431
2BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A431
2CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A431
3CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4314CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A431
5CBATHROOM - ELEVATION
ROOM TYPE
FURNITURE MARK FURNITURE COUNT
KA
ART-100 1
ART-101 1
ART-102 1
BED-100 1
BED-101 1
BED-101.1 1
BED-102 1
BED-106 1
CSG-100 2
CSG-101 1
CSG-120 1
EQU-101.1 1
LTG-100 1
LTG-101 1
LTG-102 1
UPH-100 1
UPH-100.1 1
WTR-100 & WTR-101 2
WTR-100VAL 1
ROOM TYPE
FURNITURE COUNT
KA DECOM
1
1 08/25/2016 Revision 1
11/03/16