HomeMy WebLinkAboutB16-0266_A435_1478900141.pdfQA
306
22.4
8.1
23.2
23.1
8.8
8.9
12.4
23.3
22.5
8.5
8.6
8.7
27.1
A435
2B
3B
4B
5B
A435
2C
3C
4C
5C
MIN
1'-6"
8.18
26.6 26.6
22.7
22.8
10.1
GR-E
GR-A
F1a
F2a
A4a
A4a
F4a
6'-4"
8'-4 1/4" 2'-7 1/2"
QA
306
BED-103
BED-104
BED-104.1
LTG-102
UPH-101
ART-101
WTR-102
WTR-103
UPH-100.1
TA-2
TA-6
TA-3
TA-8
TA-5
PF-1
PF-2
PF-7
PF-3
PF-6
BED-105
ART-102
QA
306
ALIGN T-01
T-02
F CT-001
W VWC-200
B CTB-001
F CT-001
C PNT-001
B CTB-001
F CPT-100
C PNT-001
W PNT-003
B VB-001
W WD-001
9.2
9.5
W SRD-001
QA
306
2.3
2.4
2.15
2.16
2.17
2.43
2.14
2.22
2.25
2.302.30
2.19
2.5
2.71
2.9
2.3
2.4
2.43
2.1
2.7
2.75
2.70
2.74 2.73
2.70 2.74
2.74
QA
306
C EXIST
7' - 10" A.F.F.
C GYP
7' - 0" A.F.F.
C EXIST
6' - 10 1/4" A.F.F.
C EXIST
7' - 2 1/2" A.F.F.
C GYP
6' - 10" A.F.F.
2.77
9.6
26.7
2.77
2.26
C GYP
7' - 0" A.F.F.
2.77
26.5
26.7
26.7
B VB-001
W PNT-003
W PNT-003 W WD-001
B VB-001 B VB-001
W PNT-003
B VB-001
W PNT-003
B CTB-001
W VWC-200
B CTB-001
W VWC-200 W SRD-001 T PNT-002
B CTB-001
W VWC-200 W SRD-001
B CTB-001
W VWC-200 W SRD-001
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE 7/11/2016
11:17:11 AM
ENLARGED
ACCESSIBLE
GUESTROOM PLANS -
QA (ROOM 306)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
A435
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION.
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE.
2.9 REMOVE TUB AND SURROUND.
2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER.
2.22 REMOVE WINDOW TREATMENTS.
2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER.
2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING.
2.30 REMOVE WALL PARTITION TO EXTENT SHOWN.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
2.70 REMOVE GRAB BARS.
2.71 REMOVE WC.
2.73 REMOVE SHELF.
2.74 REMOVE AND SALVAGE GRAB BAR TO BE REINSTALLED.
2.75 ACCESSIBLE LOOP TYPE WINDOW PULLS TO BE SALVAGED AND REINSTALLED.
2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT
BULB.
8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC
PROTECTION.
8.5 PROVIDE SECURITY LATCH.
8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR
CLOSER.
8.7 PROVIDE COVER FOR DOOR VIEWER.
8.8 PROVIDE WINDOW VALANCE.
8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS.
8.18 PROVIDE SECURITY LATCH AT 48" AFF.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH.
9.5 PROVIDE TUB SURROUND.
9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND
SPACKLE TO SMOOTH FINISH AND PAINT.
10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED.
12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH HORIZONTAL
PIECE TO SIZE.
22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND
OVERFLOW DRAIN.
22.5 PROVIDE SINK AND FAUCET.
22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION.
22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND
DIVERTER.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.2 PROVIDE AMANA PTAC AIR UNIT.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
26.7 PROVIDE LED LIGHT TO REPLACE EXISTING.
27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE.
SCALE: 1/4" = 1'-0" DRAWING REF: A112 3ACONSTRUCTION - QA (ROOM 306)
SCALE: 1/4" = 1'-0" DRAWING REF: A112
5AFF&E PLAN - QA (ROOM 306)
SCALE: 1/4" = 1'-0" DRAWING REF: A112 4AFINISH PLAN - QA
(ROOM 306)
SCALE: 1/4" = 1'-0" DRAWING REF: A112
2ADEMO PLAN - QA (ROOM 306)
SCALE:
1/4" = 1'-0" DRAWING REF: A122 6ARCP - QA (ROOM 306)
SCALE: 1/4" = 1'-0" DRAWING REF: A435
2BELEVATION
SCALE:
1/4" = 1'-0" DRAWING REF: A435 5BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A435 4BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A435 3BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A435
2CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4353CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4354CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A435
5CBATHROOM - ELEVATION
7/11/16
P.O. BOX 400, RICHMOND, VA 23218-0400
®
08/16/16