HomeMy WebLinkAboutB16-0266_A437b_1502723383.pdfDN DN
OPEN
TA-20
TA-23
TA-21
TA-22
TA-16
TA-18 TA-7
EQ EQ
MIR-200
UPH-100
UPH-100.1
ART-100
CSG-101
LTG-101
CSG-100*
BED-102
BED-100
BED-101
BED-101.1
ART-105
LTG-100
CSG-100*
CSG-119R
LTG-102
MIR-100
3'-0"
B.O. MIRROR AT 6" AFF
ART-200
TA-25
MIR-203
1'-0"
10.3
CL
EQU-100
KCONL+
524
F CPT-100
C PNT-001
C PNT-001
W PNT-003
B VB-001
W WD-001
F CT-001
W VWC-200
B CTB-001
F CT-001
B VB-001
W SRD-001
W CT-002
ALIGN
T-01
OPEN
9.2
KCONL+
524
2.3
2.4
2.15
2.16
2.17
2.43
2.3
2.4
2.43
2.9
2.5
OPEN
2.78
2.19
2.30
KCONL+
524
A437a 4B
OPEN
GR-BR
23.3
23.1
22.5
A437b
2B
4B
5B
6B
A437b 4C
5C
2C
A437b
6C
26.6
26.6
6.26.2
13.1
13.1
GR-Db
A500
1D A4a
26.3
A500
2A
A002b
4C
2D
A437a
3D
22.1
KCONL+
524
6'-0"
CL
2'-0" MIN CLR
ALIGN
A501
2A
SIM
1'-0"
EXIST. AC
UNIT
9
B VB-001
W PNT-003
NOTE: SHIFT DOOR
LOCATION DEPENDING ON
HVAC LOCATION WITHIN
CLOSET.
HVAC LEFT/DOOR RIGHT
HVAC RIGHT/DOOR LEFT
B VB-001
W WD-001
6'-9 1/8" 4'-4 1/2"
NOTE: WALL
SCONCE SHOULD
BE MOUNTED SO
THAT ROCKER
SWITCH IS
LOCATED 40" AFF.
B VB-001
W PNT-003
5'-0"
CL
EQ EQ
9
B CTB-001
CL
B VB-001
W PNT-003 3'-6"
8 1/2"
3'-10"
ENCLOSE AC
REGRIDGERANT
PIPES,
3/4" PLYWOOD
PAINTED
B CTB-001
W CT-002 3'-4"
4'-6"
4'-2"
B CTB-001
W VWC-200
4'-0"
CL
1'-4"
B CTB-001
W SRD-001
W VWC-200 4'-9"
W SRD-001
KCONL+
524
C PNT-001
C PNT-001
C EXIST
C EXIST
9.25
7' - 0" A.F.F +-
OPEN
9
5'-0"
EQ 1'-2" EQ
SCALE: 1/4" = 1'-0"
5AFURNITURE PLAN - KCON LOFT
SCALE: 1/4" = 1'-0" 4AFINISH PLAN - KCON LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN - KCON LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: A113 3ACONSTRUCTION PLAN - KCON LOFT
KEYNOTES
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.9 REMOVE TUB AND SURROUND.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER.
2.30 REMOVE WALL PARTITION TO EXTENT SHOWN.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
2.78 REMOVE STAIR AND RAILINGS.
6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH.
9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND
TRIM PAINT EXISTING TO REMAIN.
10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF
ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON
OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION.
13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL
22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD.
22.5 PROVIDE SINK AND FAUCET.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.3 PROVIDE FACEPLATE AT PHONE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
SCALE: 1/4" = 1'-0" DRAWING REF: A437b
2BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A437b 4BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A437b 5BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A437b
6BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A437b 6CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A437b
2CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A437b 4CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A437b5CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A501
6AREFLECTED CEILING PLAN - KCON LOFT
SCALE: 1/4" =
1'-0" DRAWING REF: A437b
2DKCON LOFT - BATH EAST ELEV
9
9
9
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
8/2/2017
5:35:53 PM
ENLARGED
GUESTROOM PLANS -
KCONL LOFT (ROOM
524)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A437b
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
1 08/25/2016 Revision 1
3 10/07/2016 ASI #1
9 7/21/2017 CCD-005
NOTE: ALL EXISTING LOFT WALL SCONCES TO
BE REMOVED AND REPLACED PER RFI#111
9
9
9
9
9
9
08/02/2017
08/14/17