HomeMy WebLinkAboutB16-0266_A448a_1491490946.pdfDW
UP
DW
DW
UP
DW
UP
4A
A501
KCCON
401
8.1
8.5
8.6
8.7
27.1
26.6
26.6
22.5
GR-BR
A4a 9'-0" A448a
5C
6C
A448a 2C
3C
4C
6B
A448a 3B
2B
4B
5B
GR-S
A4a
9.22
14 TREADS @ 11"
12'-10" 3'-0"
HARDWARE #1
8.8
8.8
23.3
8.10
8.10
13.1
23.2
23.1
22.2
22.7
8.16
4.1
A501
1C
1'-0"
6C
A445a
SIM
1" 1"
A002b
4D
3
22.4
A501
2A
SIM
3
2.1
2.7
2.30
2.37
2.22
2.20
2.14
2.22
2.3 2.3
2.3
2.4 2.4
2.43
2.43
2.4
2.15
2.16
2.17
2.43
2.5
KCCON
401
2.13
KCCON
401
TA-7
TA-13
TA-21
TA-19
TA-16
TA-25
MIR-202
UPH-108UPH-108
CSG-112
CPT-102
CSG-114
EQU-103
UPH-109
WTR-100 &
WTR-101
CL
EQ EQ
UPH-105.2
UPH-105.1
WTR-102
WTR-103
3
KCCON
401
ALIGN T-01
T-02
F CPT-100
C PNT-001
W PNT-003
B VB-001
C PNT-001
W VWC-200
F CT-001
B VB-001
C PNT-001
W VWC-200
F CT-001
B CTB-001 W SRD-001
9.2
KCCON
401
C GYP
7' - 0" A.F.F.
C GYP
6' - 10" A.F.F.
C EXIST
7' - 0" A.F.F.
OPEN
C EXIST
7' - 0" A.F.F.
2.26
26.5
9.6
9.6
26.7
26.7
+ -
+ -
PNT-001
PNT-001
3
3
W PNT-003
B VB-001
W PNT-003
B VB-001
30" TO CL
54" AFF
T PNT-002
W PNT-003
B VB-001
A501
6C
T PNT-002
W PNT-003
AT CLOSET
INTERIOR
ACCESS DOOR
W PNT-003
B VB-001
W PNT-003
B VB-001
WTR-100 &
WTR-101
WTR-100VAL
T PNT-002
W PNT-003
B VB-001
B CTB-001
W VWC-200
T PNT-002
5'-0"
CL
EQ EQ
3
B CTB-001
W VWC-200
W SRD-001
TA-25
4'-0"
CL
1'-6"
3
4A
A501
W SRD-001
MIR-202
CL
64" AFF
CL
19"
TA-23
W SRD-001
B CTB-001
CL
EQEQ 3
CL
1'-10"
A501
1D
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
10/12/2016
6:16:12 PM
ENLARGED
GUESTROOM PLANS -
KCCON (ROOM 401)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A448a
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION.
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE.
2.13 REMOVE TUB/SHOWER SURROUND. TUB/SHOWER TO REMAIN.
2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF.
METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS.
2.22 REMOVE WINDOW TREATMENTS.
2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING.
2.30 REMOVE WALL PARTITION TO EXTENT SHOWN.
2.37 REMOVE STAIR, TREADS, AND RAILING.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
4.1 PROVIDE STONE THRESHOLD AT DOOR.
8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR
ACOUSTIC PROTECTION.
8.5 PROVIDE SECURITY LATCH.
8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR
CLOSER.
8.7 PROVIDE COVER FOR DOOR VIEWER.
8.8 PROVIDE WINDOW VALANCE.
8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS.
8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH.
9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND
SPACKLE TO SMOOTH FINISH AND PAINT.
9.22 PROVIDE STONE TOP ON 3/4" PLYWOOD.
13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL
22.2 REFINISH AND REGLAZE TUB TO LIKE NEW CONDITION.
22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER
AND OVERFLOW DRAIN.
22.5 PROVIDE SINK AND FAUCET.
22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.2 PROVIDE AMANA PTAC AIR UNIT.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
26.7 PROVIDE LED LIGHT TO REPLACE EXISTING.
27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE.
SCALE: 1/4" = 1'-0" DRAWING REF: A113
3ACONSTRUCTION PLAN - KCCON
SCALE: 1/4" = 1'-0" DRAWING REF: D113
2ADEMOLITION PLAN - KCCON
SCALE: 1/4" = 1'-0"
5AFURNITURE PLAN - KCCON
SCALE: 1/4" = 1'-0"
4AFINISH PLAN - KCCON
SCALE: 1/4" = 1'-0" DRAWING REF: A123
6AREFLECTED CEILING PLAN - KCCON
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
5CELEVATION - KITCHEN
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
2BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
5BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
4BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
3BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
6CELEVATION - KITCHEN
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
3CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
4CELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
6BELEVATION - BATHROOM
SCALE: 1/4" = 1'-0" DRAWING REF: A448a
2CELEVATION - BATHROOM
1 08/25/2016 Revision 1
2 09/19/2016 CCD-002
3 10/07/2016 ASI #1
3
3
10/17/2016
04/06/17