Loading...
HomeMy WebLinkAboutB16-0266_A448b_1478902443.pdfDW DN DW DN DW DN K+ 501 1A A448a 3'-0" 14 TREADS @ 11" 13'-9" 3'-0" EXIST STEEL BEAM - VERIFY IN FIELD 1'-2 1/4" 1" OPEN 26.6 23.1 22.1 22.5 23.2 23.3 26.6 26.6 GR-BR A448b 2E A448b 3E A448b 4D 4E 5E 6E 6D 3D 5D A448b 6A 6C 6B 2D 6.3 6.26.2 3.1 3.4 GR-D 2'-0" EQ 6'-0" EQ A500 1D 13.1 26.3 26.3 K+ 501 1'-1" EXIST STEEL BEAM - VERIFY IN FIELD 1" OPEN TA-18 TA-23 TA-21 TA-20 TA-22 TA-16 CSG-100 LTG-101 ART-102 LTG-100 CSG-101 BED-106 BED-101 CSG-100 BED-102 BED-101.1 BED-100 UPH-104 ART-101 UPH-102.1 UPH-102.2 UPH-102.3 MIR-200 MIR-100 EQU-101.1 CSG-102 LTG-102 ART-100 UPH-100 UPH-113 CSG-117 CL CL CL CL 4'-8" 4'-8" 2'-2" 1'-6 3/4" CL EQ EQ CL CL 1'-4" 8'-0" UPH-100.1 K+ 501 EXIST STEEL BEAM - VERIFY IN FIELD OPEN WSRD-001 ALIGN T-01 C PNT-001 W VWC-200 F CT-001 B CTB-001 F CPT-100 C PNT-001 W PNT-003 B VB-001 F CPT-100 C PNT-001 W PNT-003 B VB-001 W CT-002 F CT-001 B VB-001 OPEN 2.9 2.5 2.3 2.4 2.15 2.16 2.17 2.43 2.3 2.3 2.4 2.15 2.16 2.17 2.43 2.4 2.43 K+ 501 2.37 2.86 2.19 W PNT-003 W PNT-003 B VB-001 W PNT-003 B VB-001 CL CL 16" 96" CL54" AFF W PNT-003 B VB-001 B CTB-001 W VWC-200 W SRD-001 B CTB-001 W VWC-200 B CTB-001 W VWC-200 TA-23 W SDR-001 W SRD-001 B CTB-001 W CT-002 MIR-200 CL 60" EQ EQ W PNT-003 B VB-001 CL 60" AFF CL CL CL CL 56" 56" 26" 18" CL36" AFF ART-101 LTG-101 CSG-101 ART-102 W PNT-003 B VB-001 T PNT-002 W PNT-003 B VB-001 W PNT-003 B VB-001 T PNT-002 W PNT-003 AT CLOSET INTERIOR 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 8/29/2016 4:13:16 PM ENLARGED GUESTROOM PLANS - KING CORNER CONDO LOFT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A448b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A113 5BCONSTRUCTION PLAN - ROOM 401 - UPPER LEVEL/LOFT SCALE: 1/4" = 1'-0" 5CFF&E PLAN - ROOM 401 SCALE: 1/4" = 1'-0" 3CFINISH PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: D113 3BDEMO PLAN - ROOM 401 - UPPER LEVEL/LOFT KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.86 REMOVE CLOSET DOORS AND SHELVES. PREPARE FOR NEW. 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 3.4 EXTEND FLOOR FRAMING OVER TO TOP OF NEW WALL BELOW. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 6.3 42" HIGH GUARDRAIL. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6AELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6CELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 2DELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b3DBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6DBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 5DBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 4DBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 2EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b3EELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b4EELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b5EELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6EELEVATION 1 1 08/25/2016 Revision 1 11/03/16