HomeMy WebLinkAboutB16-0266_A450_1478900168.pdfH
REF
K
206
2.22
2.3
2.4
2.2
2.34
2.43
2.342.34
2.14
2.16
2.17
K
206
22.6
22.5
22.1
8.1
27.1
8.7
12.4
8.8
8.10
23.1
GR-A
GR-E
23.3
23.2
26.1
26.6
26.6
26.2
A450
2B
3B
4B
6B
A450
2C
3C
4C
5C
ALIGN
A4a
A4a
10'-0 3/4"
5'-0"
K
206
W
SRD-001
ALIGN
T-01
T-02
F CPT-100
C PNT-001
W PNT-003
B VB-001
W WD-001
F CT-001
B CTB-001
C PNT-001
F CT-001
W VWC-200
B CTB-001
W CT-002
9.18
9.2
K
206
CSG-100
CSG-101
BED-100
BED-101
BED-101.1
CSG-100
UPH-100
LTG-102
WTR-101
EQU-100
CSG-102
UPH-102 LTG-103
CSG-204
MIR-200
BED-102
UPH-102.1
ART-101
CSG-103
TA-2
TA-4
TA-3
TA-6
TA-7
TA-1
TA-5
PF-1
PF-2
PF-5
PF-3
PF-4
UPH-102.2
UPH-102.3
BED-106
UPH-100.1
ART-100
MIR-100
CSG-107
ART-102
LTG-100
LTG-101
WTR-100
W PNT-003
B CTB-001
W PNT-003
T PNT-002
B VB-001
W PNT-003
B VB-001 B CTB-001
W PNT-003 W WD-002
B VB-001
W PNT-003
B VB-001
W PNT-003
T PNT-002
W SRD-001
B CTB-001
W VWC-200 W SRD-001
B CTB-001
W CT-001
B CTB-001
W VWC-200 W SRD-001 T PNT-002
C EXIST
7' - 11" A.F.F.
C EXIST
7' - 4" A.F.F.
C EXIST
7' - 11" A.F.F.
C EXIST
8' - 2 1/2" A.F.F.
C EXIST
8' - 2 1/2" A.F.F.
C EXIST
7' - 0" A.F.F.
2.6
2.6
9.6
9.6
26.10
26.10
26.5
26.10
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
11:18:44 AM
ENLARGED
GUESTROOM PLANS -
KING (ROOM 206)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
A450
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
2.2 REMOVE DOOR, HARDWARE AND FRAME.
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.6 REMOVE CEILING MOUNTED LIGHT FIXTURES.
2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.22 REMOVE WINDOW TREATMENTS.
2.34 REMOVE EQUIPMENT AND RETURN TO OWNER.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR
ACOUSTIC PROTECTION.
8.7 PROVIDE COVER FOR DOOR VIEWER.
8.8 PROVIDE WINDOW VALANCE.
8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS.
9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT
FINISH.
9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND
SPACKLE TO SMOOTH FINISH AND PAINT.
9.18 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS,
CONTROLS, CURTAIN & ROD.
12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH
HORIZONTAL PIECE TO SIZE.
22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD.
22.5 PROVIDE SINK AND FAUCET.
22.6 PROVIDE WC.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
23.2 PROVIDE AMANA PTAC AIR UNIT.
23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT
SCREEN AT 60" A.F.F.
26.1 PROVIDE NON-SWITCHED DUPLEX OUTLET 32"-36" ABOVE THE FINISHED
FLOOR.
26.2 PROVIDE NON-SWITCHED DUPLEX OUTLET.
26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
26.10 PROVIDE CEILING MOUNTED LIGHT FIXTURE
27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE.
SCALE: 1/4" = 1'-0" DRAWING REF: A112
2ADEMO PLAN - K (ROOM 206)
SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION - K (ROOM 206)
SCALE: 1/4" = 1'-0" DRAWING REF: A1124AFINISH PLAN - K (ROOM 206)
SCALE: 1/4" = 1'-0" DRAWING REF: A112 5AFF& E PLAN - K (ROOM 206)
SCALE: 1/4" = 1'-0" DRAWING REF: A450 3BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: 2 4BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A450 6BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: 2
2BELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A450
2CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A450 3CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A4504CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A450 5CBATHROOM - ELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A122
6ARCP - K (ROOM 206)
7/11/16
P.O. BOX 400, RICHMOND, VA 23218-0400
®
08/16/16