Loading...
HomeMy WebLinkAboutB16-0266_A451a_1502723340.pdfDKL 436 A451a 2B 6B 5B 4B HARDWARE #1 8.8 8.9 26.6 27.1 8.7 A501 2A SIM GR-S 3'-0" MIN CLR 7'-2 1/4" 4'-2 1/2" 6'-4 1/2" DKL 436 CSG-112 UPH-105 UPH-105.2 UPH-105.1 CSG-113 UPH-108UPH-108 EQU-103 CL WTR-103 WTR-102 EQU-103.1 UPH-106 UPH-106.1 DKL 436 2.1 2.7 2.3 2.4 2.15 2.16 2.17 2.43 DKL 436 F CPT-100 C PNT-001 W PNT-003 B VB-001 F CT-001 B VB-001 ALIGN T-01 T-02 9.2 C PNT-001 W PNT-003 DKL 436 C EXIST 7' - 0" A.F.F. PNT-001 PNT-001 9.6 26.7 9.6 26.7 A500 6B SIM C EXIST VARIES 9.25 9 6" CL B VB-001 W PNT-003 W PNT-003 B VB-001 B VB-001 W PNT-003 CL EQ EQ 6" A501 6C SIM W PNT-003 B VB-001 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 8/2/2017 5:38:29 PM ENLARGED GUESTROOM PLANS - DKL (ROOM 436) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A451a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A452 5AFURNITURE PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A452 2ADEMOLITION PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A4524AFINISH PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A452 6AREFLECTED CEILING PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A010 2BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A0104BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 5BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A0106BELEVATION 9 9 9 9 9 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 08/14/17