HomeMy WebLinkAboutB16-0266_A451b_1502723393.pdfDKL+
536
A451b 4E
3E
5E
6E
A451c
3A
2A
A451c
2B
A451b
5C
6C
5D
6D
13.1
3.1
13.1 6.26.2
26.6
26.6
23.1
22.1
26.6
22.5
6.26.2
26.6 2'-0" MIN CLR
MIN CLR
2'-0"
A4a
GR-Dc
GR-Dc
A4a
A500
1D
A500
2A
A500
1D
OPEN
ALIGN
1A
1B
3B
A501
2A
SIM
ALIGN WALL
WITH
EXISTING
CEILING
BEAM ABOVE
ALIGN WALL
WITH
EXISTING
CEILING
BEAM ABOVE
3'-0"
DKL+
536
2.5
2.51
2.19
2.9
2.3
2.4
2.43
2.37
2.3
2.4
2.15
2.16
2.17
2.18
2.43
2.3
2.4
2.15
2.16
2.17
2.18
2.43
DKL+
536
TA-18
TA-7
TA-20 TA-23
TA-21
TA-22 TA-16
TA-25
MIR-100
MIR-200 MIR-203
LTG-101
BED-100
BED-101
BED-101.1
BED-102
CSG-100
CSG-101
EQU-101.1
LTG-101
BED-100
BED-101
BED-101.1
BED-102
CSG-100
CSG-101
EQU-101.1
ART-102
ART-101 CSG-121
CSG-121
ART-102
ART-101
LTG-100
CSG-100
CSG-100
LTG-100
DKL+
536
ALIGN T-01
F CPT-100
C PNT-001
W PNT-003
B VB-001
C PNT-001
W VWC-200
F CT-001
B CTB-001
W WD-001
W CT-002 W SRD-001
0"
C PNT-001
W VWC-200
F CT-001
B VB-001
F CPT-100
C PNT-001
W PNT-003
B VB-001
W WD-001
W WD-001
B VB-001
CL
CL
50 1/2" 27"
60"
36"
9
NOTE: WALL
SCONCE
SHOULD BE
MOUNTED SO
THAT ROCKER
SWITCH IS
LOCATED 40"
AFF.
W PNT-003
B VB-001
CL CL
3'-10 3/4"
2'-2"
W PNT-003
B VB-001
W PNT-003
B VB-001
T PNT-002
W PNT-003
AT CLOSET
INTERIOR
W PNT-003
B VB-001
T PNT-002
W PNT-003
AT CLOSET
INTERIOR
W PNT-003
B VB-001
EQU-101.1 2'-6"
CL 3'-3"
W PNT-003
B VB-001
CL CL
5'-0 3/4"
2'-2" 4'-10 1/4" CL5'-0"
W WD-001
B VB-001
CL
CL
26 1/2" 51 1/2"
NOTE: WALL
SCONCE
SHOULD BE
MOUNTED SO
THAT ROCKER
SWITCH IS
LOCATED 40"
AFF.
C EXIST
7' - 0" A.F.F.
PNT-001
PNT-001
PNT-001
C EXIST
OPEN
9.25
C EXIST
OPEN
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
8/2/2017
5:38:41 PM
ENLARGED
GUESTROOM PLANS -
DKL LOFT (ROOM 536)
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A451b
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
3 10/07/2016 ASI #1
9 7/21/2017 CCD-005
KEYNOTES
2.3 REMOVE FLOOR FINISH TO SUBFLOOR.
2.4 REMOVE WALL BASE.
2.5 REMOVE SINK, FAUCET AND VANITY.
2.9 REMOVE TUB AND SURROUND.
2.15 REMOVE WALL MOUNTED MIRRORS.
2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER.
2.17 REMOVE WALL MOUNTED LIGHTING.
2.18 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW.
2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER.
2.37 REMOVE STAIR, TREADS, AND RAILING.
2.43 REMOVE WALL FINISH TO SUBSTRATE.
2.51 REMOVE RAILING.
3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS.
6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW.
9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND
TRIM PAINT EXISTING TO REMAIN.
13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL
22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD.
22.5 PROVIDE SINK AND FAUCET.
23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE.
26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR.
SCALE: 1/4" = 1'-0" DRAWING REF: A113 4ACONSTRUCTION PLAN - DKL LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: A501
2ADEMOLITION PLAN - DKL LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: A501
2CFURNITURE PLAN - DKL LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: A501
6AFINISH PLAN - DKL LOFT
SCALE: 1/4" = 1'-0" DRAWING REF: A451b 4EELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b 5EELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b
6EELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b
3EELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b 5CELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b 6CELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b
5DELEVATION
SCALE: 1/4" = 1'-0" DRAWING REF: A451b
6DELEVATION
9
9
9
SCALE: 1/4" = 1'-0" DRAWING REF: A123 4CREFLECTED CEILING PLAN - DKL LOFT
9
9
9
9
NOTE: ALL EXISTING LOFT WALL SCONCES TO
BE REMOVED AND REPLACED PER RFI#111
9
08/02/2017
08/14/17