HomeMy WebLinkAboutB16-0266_A502_1502723394.pdfHEARTH BEYOND,
POLISHED, DARK STAINED
CONCRETE SLAB, TYP
1 x 8 R.S. CEDAR
SHIPLAP PLANKS
ON FURRING
STRIPS
RECESSED ACCESS
DOOR, APPLY GYPSUM
FINISH TO PANEL.
PAINT TO MATCH
ADJACENT FINISH
1 x 6 TONGUE AND GROOVE CEDAR
GYP BD CEILING TO CONCEAL
STRUCTUAL BEAM
HEARTH BEYOND
FIREBOX BEYOND
13' - 4"
FINISH FLOOR
EXISTING PRECAST
STRUCTURAL WALL
2x8 WOOD PLATE
STRUCTURAL STEEL BEAM
T.O. STEEL BEAM 14' - 10 1/2"
2 1/2" METAL STUDS TO CLEAR B.O. BEAM
3 5/8" METAL STUDS
3 5/8" METAL STUD
FLUE BEYOND
STONE TILE, STN-003
1'-4"
4'-3 1/2"
1'-0 1/2"
CL
FIREBOX BEYOND
1'-4"
FIREPLACE INSERT
1 x 6 TONGUE AND GROOVE CEDAR
BRACING FOR STRUCTURAL
SUPPORT AS NECESSARY
3 5/8" METAL STUDS
5/8" CEMENT BOARD
MESH AND ADHESIVE
STONE TILE STN-003
1/4" CEMENTITIOUS FINISH ON MESH ON 3/4"
PLYWOOD SUBSTRATE
INSULATION AND FIREPROOFING
PER FIREPLACE MANUFACTURER,
MAINTAIN CLEARANCES
14" DIA FLUE, 18" CLEARANCE FROM ANY
COMBUSTIBULES, EXTEND DIRECTLY
BETWEEN EXISTING WOOD JOISTS, AVOID
CONFLICT WITH STEEL BEAM
REF MANUFACTURER FOR NECESSARY
VENTING, COMBUSTION AIR INTAKE, GLASS
COOLING INTAKES, CLEARANCES, PROPER
INSTALATION AND OTHER NECESSARY
MECHANICAL ITEMS. COORDINATE LOCATION
WITH STRUCTURAL ENGINEER
EXISTING STRUCTURAL COLUMN, ENSURE
EXISTING LOCATION NOT HINDERING DESIGN,
DO NOT PROCEED WITHOUT CONTACTING
ARCHITECT IF CONFLICTING
STONE BEYOND
FIREPLACE INSERT GLASS, REMOVABLE, REF
SHOP DRAWINGS
TOP OF CONCRETE HEARTH REF SHOP DRAWINGS
EXISTING STRUCTURAL COLUMN BEYOND
METAL STUDS, BRACE
FOR STRUCTURAL
SUPPORT AS
NECESSARY, SPECIALTY
ENGINEER TO PROVIDE
SIZE, GAUGE AND
SPACING
3 5/8" METAL STUDS
5/8" CEMENT BOARD
MESH AND ADHESIVE
STONE TILE STN-003
EXISTING WOOD
TRUSSES @ 24" O.C.
REMOVABLE FRAME
A502
6A
A502
6B
LIGHTBOX BEYOND,
TYP
MECHANICAL AIR
DIFFUSER, REF SHEET
M202 FOR DETAILS
1'-6" 1'-0" 1'-11 7/8"
4'-3 7/8"
1'-6" MIN CLR
2'-6"
COORDINATE NECESSARY
STRUCTURAL SUPPORT WITH
STRUCTURAL ENGINEER
6'-0 3/4"
COORDINATE
NECESSARY
STRUCTURAL SUPPORT
WITH STRUCTURAL
ENGINEER
EXISTING STRUCTURAL COLUMN BEYONDEXISTING STRUCTURAL COLUMN BEYOND
BOTTOM OF FIREBOX OPENING TO MATCH TOP OF
REMOVABLE FRAME (VERIFY HEIGHT)
1'-4"
1'-4"
4'-10"
NOTE:
SEQUENCE OF FIREPLACE
CONSTRUCTION SHALL BE:
1. CONSTRUCTION OF LOBBY SPACE
102 SIDE OF FIREPLACE INCLUDING
HEARTH AND BASE CONCRETE
BELOW FIREBOX
2. INSERT FIREBOX
3. CONSTRUCTION OF LOBBY SPACE
103 SIDE OF FIREPLACE INCLUDING
HEARTH
4. COMPLETE CONSTRUCTION AND
FINISHES
4'-3 3/4"
1'-0" 11 7/8" 1'-0 1/4" 1'-3 3/4"
1'-6 3/4" 6 1/4"
ENGINEERED AIR DIFFUSER,
REF MECAHNICAL, SHEET
M202 FOR DETAILS 2'-0"
2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 1'-4" 3" TYP
BRACING AS NECESSARY
3 5/8" METAL STUDS
5/8" CEMENT BOARD
MESH AND ADHESIVE
STONE, STN-003
3 5/8" METAL STUDS,
BRACE FOR STRUCTURAL
SUPPORT AS NECESSARY
EXISTING WOOD
TRUSSES @ 24" O.C.
1/4" CEMENTITIOUS FINISH ON MESH,
TOP, BOTTOM, AND EXPOSED SIDES
1'-1"
3"
INFILL AREA
3/4" PLYWOOD SUBSTRATE ON TOP AND SIDES
2x4 FRAMING
1/4" PLYWOOD SUBSTRATE ON BOTTOM
2'-0" TYP 3C
A502
5C
A502
6C
A502
A502
2E
A502
2D
A502
2B
10'-4" TO END OF PRECAST WALL
OFFSET FLUE TO AVOID CONFLICT WITH COLUMN, 18"
TOTAL CLEAR PATH AROUND 14" DIA FLUE, RUN
DIRECTLY IN BETWEEN WOOD JOISTS (24" 0.C.) ABOVE
FULLY ENCAPSULATE EXISTING CONCRETE STRUCTURAL COLUMN
WITHIN FIREBOX, REF MANUFACTURER CUSTOM DETAILS
6A
A502
6B
A502 1'-6" 27'-0"
2'-3" 4'-2" 3'-6 3/4" 17'-1" 1'-10 1/4"
3 3/8" 2'-9 5/8"
4'-3 1/2"
CUSTOM FIREBOX, OVERALL
DIMENSIONS 8'-0" x 1'-7 3/4"
1'-2 1/2" 11 3/4" 3"
1'-3 3/4" 1'-11 7/8" 11 7/8" 1'-6" FIREBOX
FIREBOX
8'-0" 8'-0"
FIREBOX
6'-0 1/2" 2'-5 7/8" 1'-6 3/4"
1'-1" 1'-3 3/4"
11 7/8" 4'-3 1/2"
CL9 3/4" 2 1/4"
CL2" 10" SEALANT, TYP AT ALL INTERIOR CORNERS
WHERE WOOD PLANK WALL MEETS STONE
FIREPLACE MATERIAL
1x4 WOOD FURRING
2x6 R.S. CEDAR SHIPLAP PLANKS
STONE, STN-003, MITER ALL OUTSIDE CORNERS
5/8" CEMENT BOARD
3 5/8" METAL STUDS
SHIM AS NECESSARY
EXISTING STRUCTURAL
PRECAST WALL
STRUCTURAL STEEL
COLUMN, REF
STRUCTURAL
EXISTING STRUCTURAL COLUMN,
ENSURE EXISTING LOCATION NOT
HINDERING DESIGN, DO NOT
PROCEED WITHOUT CONTACTING
ARCHITECT IF CONFLICTING
1 5/8" METAL STUDS
3 5/8" METAL STUDS
5/8" CEMENT BOARD
MESH AND ADHESIVE
STONE TILE, STN-003
CONCRETE HEARTH
1/4" CEMENTITIOUS
FINISH ON MESH ON
3/4" PLYWOOD
SUBSTRATE
ACCESS DOOR LATCH
A502
2A
EXISTING STRUCTURAL COLUMN, ENSURE
EXISTING LOCATION NOT HINDERING DESIGN, DO
NOT PROCEED WITHOUT CONTACTING
ARCHITECT IF CONFLICTING
ACCESS DOOR HINGE
ATTACH RECESSED ACCESS
DOOR TO METAL STUD
ACCESS DOOR WITH GYB BD
APPLIED AS FINISH MATERIAL TO
PANEL, PAINT TO MATCH
ADJACENT FINISH
CAST-IN-PLACE CONCRETE BELOW, SOLID FILLED AND
REINFORCED TO SUPPORT WEIGHT OF HEARTH
REBAR SUPPORTS, RUN IN PERPENDICULAR DIRECTIONS,
STRUCTURAL CONSULTANT TO ENSURE PROPER SUPPORT
TYPR 0' - 0 3/4"
TYPR 0' - 0 3/4"
EXISTING STRUCTURAL COLUMN, ENSURE
EXISTING LOCATION NOT HINDERING
DESIGN, DO NOT PROCEED WITHOUT
CONTACTING ARCHITECT IF CONFLICTING
REINFORCED CONCRETE HEARTH
CUSTOM FIREBOX INSULATED PANEL
3 5/8" METAL STUDS
5/8" CEMENT BOARD
MESH AND ADHESIVE
STONE TILE STN-003
LEAVE 1/8" GAP BETWEEN FRAM AND
FINISH MATERIAL
CUSTOM FIREBOX REMOVABLE FRAME
CUSTOM FIREBOX REMOVABLE GLASS
CAST-IN-PLACE CONCRETE VENEER WALL
ON 3/4" PLYWOOD ON 3 5/8" METAL STUD,
REINFORCE AS NECESSARY
STRUCTURAL STEEL COLUMN, REF
STRUCTURAL
LEAVE 1/8" GAP BETWEEN FRAME AND
ADJACENT FINISH MATERIAL
REMOVABLE GLASS FOR
FIREPLACE INSERT
FIREPLACE INSERT INSULATED PANEL
FIREPLACE INSERT BASE, REF MANUFACTURER
CUSTOM DETAILS
REINFORCED CAST-IN-PLACE
CONCRETE SLAB HEARTH
REINFORCED, CAST-IN-
PLACE CONCRETE
MESH AND ADHESIVE
STONE, STN-003
EXISTING STRUCTURAL CONCRETE COLUMN BEYOND
FINISH FLOOR, REF FINISH PLAN
STONE BEYOND
REMOVE CONCRETE AND EXTEND
REBAR SUPPORTS INTO SLAB
1/8" MIN
6"
3 5/8"4"
1'-0"
1'-0"
REINFORCED, CAST-IN-
PLACE CONCRETE
3 5/8" METAL STUDS
STONE TILE STN-003
1/4" CEMENTITIOUS
FINISH ON MESH ON 3/4"
PLYWOOD SUBSTRATE
MESH AND ADHESIVE
5/8" CEMENT BOARD
INSULATION AND
FIREPROOFING PER
FIREPLACE
MANUFACTURER, MAINTAIN
CLEARANCES
STONE BEYOND
REMOVABLE FRAME
CUSTOM
FIREBOX
EXISTING CONCRETE
STRUCTURAL COLUMN
LEAVE 1/8" MIN GAP
BETWEEN FIREBOX
TRIM AND FINISH
MATERIAL
1/8" MIN
7 1/8"
8"
STRUCTURAL STEEL
COLUMN, COORD. WITH
STRUCTURAL
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
8/2/2017
5:39:47 PM
FIREPLACE DETAILS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/2016 -
CONSTRUCTION
DOCUMENTS
A502
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/2" = 1'-0" DRAWING REF: A401bx
3CSECTION - FIREPLACE
SCALE: 1/2" = 1'-0" DRAWING REF: A401bx5CSECTION - FIREPLACE
SCALE: 1/2" = 1'-0" DRAWING REF: A401bx6CSECTION - FIREPLACE
SCALE: 1/2" = 1'-0" DRAWING REF: A401a
5AENLARGED PLAN - FIREPLACE
SCALE: 3" = 1'-0" DRAWING REF: A502
2AENLARGED PLAN DETAIL
- FIREPLACE @ WOOD WALL
SCALE: 1 1/2" = 1'-0" DRAWING REF: A502
2DPLAN DETAIL - FIREPLACE
SCALE: 1 1/2" = 1'-0" DRAWING REF: A502
2BPLAN DETAIL - FIREPLACE
SCALE: 1 1/2" = 1'-0" DRAWING REF: A502
2EPLAN DETAIL - FIREPLACE
SCALE: 1 1/2" = 1'-0" DRAWING REF: A502
6ASECTION DETAIL - HEARTH
SCALE: 1 1/2" = 1'-0" DRAWING REF: A502 6BSECTION DETAIL - HEAD
1 08/25/2016 Revision 1
2 09/19/2016 CCD-002
6 3/27/2017 RFI 73R1 Response
9 7/21/2017 CCD-005
9
9
9
9
9
9
08/02/2017
08/14/17