HomeMy WebLinkAboutB16-0266_E001_1478902289.pdfSYMBOL DESCRIPTION DUPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT DUPLEX RECEPTACLE, SPLIT WIRED, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT SINGLE RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT GFCI RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM GFCI QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AND MOUNTING AS INDICATED BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE AND NUMBER OF CONDUCTORS, DASHED LINES INDICATE UNDER FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. INDICATES PHASE CONDUCTOR INDICATES NEUTRAL CONDUCTOR INDICATES GROUNDING CONDUCTOR NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MANUAL MOTOR STARTER MAGNETIC MOTOR STARTER COMBINATION STARTER/DISCONNECT MOTOR DUPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT FLOOR BOX, FLUSH FLOOR, WITH (2) DUPLEX RECEPTACLES AND SPACE FOR (2) SINGLE GANG TELECOMMUNICATION OUTLETS FLOOR BOX, POKE-THRU TYPE WITH (2) DUPLEX RECEPTACLES AND SPACE FOR TELECOMMUNICATION OUTLETS JUNCTION BOX SYSTEM FURNITURE CONNECTION, WALL AND FLOOR MOUNT PANELBOARD, SURFACE MOUNT PANELBOARD, RECESS MOUNT TRANSFORMER, DRY TYPE PLUG LOAD CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM DUPLEX RECEPTACLE, NEMA 5-20R, CEILING MOUNT, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SURFACE RACEWAY, DEVICES AS INDICATED PLUGMOLD, OUTLET EVERY 12" ON CENTER, ALTERNATE NEMA 5-15R RECEPTACLE WITH USB CHARGING PORT POWER LEGEND GENERAL DEMOLITION NOTES DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND EXISTING DRAWINGS. VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE. DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND NOT INDICATED FOR REUSE OR SALVAGE. MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE CIRCUITS AS REQUIRED DUE TO THE WORK. EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE WALL/FLOOR AND PATCH. REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE SOURCE. 1. 2. 3. 4. 5. 6. 7. LIGHTING LEGEND SYMBOL DESCRIPTION LIGHT FIXTURE LIGHT FIXTURE ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, WALL MOUNT LIGHT FIXTURE, WALL MOUNT, ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, POLE MOUNT EXIT SIGN, WALL MOUNT +90" AFF AND CEILING MOUNT, SHADED SIDE INDICATES FACE(S) OF SIGN, DIRECTIONAL CHEVRONS AS INDICATED EGRESS LIGHT WITH BATTERY PACK, WALL MOUNT +90" AFF OCCUPANCY SENSOR, DUAL TECHNOLOGY, CEILING MOUNT, OMNI-DIRECTIONAL AND DIRECTIONAL PHOTO CELL LIGHT SWITCH, 120/277-VOLT, 1HP RATED, MOUNT +46" AFF, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT LIGHT SWITCH, LOW VOLTAGE, MOUNT +46" AFF, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT ROOM CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM LOW VOLTAGE CABLING FOR LIGHTING CONTROL SYSTEM, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SYMBOL DESCRIPTION CCTV CAMERA KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE CARD READER WITH KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE MAGNETIC LOCK ELECTRIC STRIKE ELECTRIC LOCK GLASS BREAK SENSOR SECURITY LEGEND SYMBOL DESCRIPTION TELECOMMUNICATIONS OUTLET, MOUNT +18" AFF, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS OUTLET, FLUSH FLOOR MOUNT, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE SOUND SYSTEM SPEAKER, CEILING AND WALL MOUNT COAXIAL CABLE TELEVISION OUTLET, MOUNT +18" AFF INTERCOM STATION, MOUNT +46" AFF 19" EQUIPMENT RACK TELECOMMUNICATIONS OUTLET, CEILING MOUNT, PROVIDE 1" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS LEGEND GENERAL NOTES PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THE WORK. PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS: A. LIGHT FIXTURES B. PANELBOARDS / CIRCUIT BREAKERS C. SAFETY SWITCHES D. TRANSFORMERS E. WIRING DEVICES F. CONDUCTORS G. CONDUIT H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON DRAWINGS SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR EVALUATION. PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L. LABEL, AND LISTED FOR ITS INSTALLED APPLICATION. PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME MANUFACTURER. USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT MOUNTED DEVICES. ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS. PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS. IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED. PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE RATING ON THE MOTORS BEING INSTALLED. PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE HEATING, AIR CONDITIONING, OR REFRIGERATION EQUIPMENT. PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE BRANCH CIRCUITS. PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY. PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE FOR EACH PANELBOARD AFFECTED BY THE WORK. PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION. BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL. PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT. GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER OWNER ACCEPTANCE. PERFORM ALLWORK IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (2011), VIRGINIA UNIFORM STATEWIDE BUILDING CODE (2012), ADA STANDARDS FOR ACCESSIBLE DESIGN (2010), AND CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL, REV 0 (2013). CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF VIRGINIA STATE FIRE PROTECTION CODE (2012) AND NFPA 241-2000 "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" ON SITE. NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE WATCH IN ACCORDANCE WITH VIRGINIA STATEWIDE FIRE PREVENTION CODE (2012), PARAGRAPH 901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO TIMES WHEN THE BUILDING IS NORMALLY UNOCCUPIED. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. SYMBOL DESCRIPTION FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN +96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN + 96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM MANUAL PULL STATION, MOUNT +46" AFF FIRE ALARM SMOKE DETECTOR, CEILING MOUNT FIRE ALARM HEAT DETECTOR, CEILING MOUNT FIRE ALARM DUCT SMOKE DETECTOR FIRE ALARM TAMPER SWITCH FIRE ALARM FLOW SWITCH FIRE ALARM PRESSURE SWITCH FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL MODULE FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED MAGNETIC DOOR HOLD OPEN DEVICE FIRE ALARM LEGEND SPECIFICATIONS RELATED DOCUMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDINGGENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATIONS, APPLY. 260513 - CONDUCTORS AND CABLES 1. PROVIDE COPPER CONDUCTORS, NEMA WC/ICEA S-95-658 TYPE THHN/THWN-2, TYPE UF, AND TYPE SO. 2. PROVIDE SOLID CONDUCTORS FOR #10 AWG AND SMALLER, STRANDED FOR #8 AWG AND LARGER. 3. COLOR CODE ALL CONDUCTORS. 260526 - GROUNDING AND BONDING 1. PROVIDE 3/4" DIA X 10'-0" COPPER CLAD GROUND RODS. 2. PROVIDE INSULATED GROUNDING CONDUCTORS WITH ALL FEEDER AND BRANCH CIRCUITS. 260529 - HANGERS AND SUPPORTS 1. PROVIDE HOT DIP GALVANIZED STEEL SLOTTED SUPPORT SYSTEMS WITH MFMA-4 FACTORY FABRICATED COMPONENTS FOR FIELD ASSEMBLY. 2. PROVIDE STEEL HANGERS, CLAMPS, AND ASSOCIATED FITTINGS FOR CONDUIT AND CABLE SUPPORT. 3. ATTACHMENTS 3.1 WOOD - LAG SCREWS. 3.2 CONCRETE - EXPANSION ANCHORS. 3.3 MASONRY - TOGGLE TYPE BOLTS. 3.4 STEEL - BEAM CLAMPS. 3.5 LIGHT STEEL - SHEET METAL SCREWS. 260533 - RACEWAYS AND BOXES 1. METAL CONDUIT 1.1 GRC - COMPLY WITH ANSI C80 AND UL 6. 1.2 EMT - COMPLY WITH ANSI C80.3 AND UL 797. 1.3 FMC - COMPLY WITH UL 1; ZINC-COATED STEEL. 1.4 LFMC - FLEXIBLE STEEL CONDUIT WITH PVC JACKET, COMPLY WITH UL 360. 1.5 FITTINGS - COMPLY WITH FB 1 AND UL 514B. 1.6 FITTING FOR EMT - STEEL SETSCREW. 2. NON-METALLIC CONDUIT 2.1 PVC, SCHEDULE 40 - COMPLY WITH NEMA TC 2 AND UL 651. 3. APPLICATIONS 3.1 OUTDOORS EXPOSED US GRC, UNDERGROUND USE PVC. 3.2 INDOORS EXPOSED USE GRC, CONCEALED US EMT. 3.3 CONNECTION TO VIBRATING EQUIPMENT US LFMC OR FMC. 3.4 PROVIDE MINIMUM 3/4" RACEWAYS. 3.5 PROVIDE PULL STRING IN ALL EMPTY CONDUITS. 260553 - IDENTIFICATION 1. PROVIDE LAMINATED ACRYLIC PLASTIC SIGNS FOR ALL EQUIPMENT, ENGRAVED LEGEND WITH BLACK LETTERS ON WHITE FACE, PUNCHED OR DRILLED FOR MECHANICAL FASTENERS. 2. PROVIDE SIGNS DESIGNATING EQUIPMENT IDENTIFICATIONS, SYSTEM VOLTAGE AND PHASE, AND PPE WARNING. 3. FOR EXTERIOR APPLICATIONS PROVIDE UV STABILIZED SIGNS. 262200 - LOW VOLTAGE TRANSFORMERS 1. DRY TYPE, COPPER COIL, 115 DEGREE RISE, VENTILATED TRANSFORMERS WITH GRAY FINISH. 2. MOUNT WITH VIBRATION DAMPENING SUPPORTS. 262416 - PANELBOARDS 1. COMPLY WITH NEMA PB 1 AND NFPA 70. 2. ENCLOSURE - FLUSH AND SURFACE MOUNT GALVANIZED STEEL DEAD FRONT CABINETS RATED FOR ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. 3. HARD DRAWN COPPER, 98 PERCENT CONDUCTIVITY PHASE, NEUTRAL, AND GROUND BUSES. 4. MECHANICAL TYPE LUGS. 5. PROVIDE MOUNTING BRACKETS, BUS CONNECTIONS, FILLER PLATES AND NECESSARY APPURTENANCES REQUIRED FOR FUTURE DEVICE. 6. ASSEMBLY FULLY RATED AND NRTL LISTED FOR 100 PERCENT INTERRUPTING CAPACITY. 7. PROVIDE THERMAL MAGNETIC CIRCUIT BREAKERS WITH STANDARD TRIP RATINGS AND NUMBER OF POLES, MECHANICAL LUGS AND LISTED FOR INTERRUPTING CAPACITY TO MATCH PANELBOARD. 8. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY CARD INSIDE DOOR, TRANSPARENT CARD HOLDER, IDENTIFYING SPECIFIC PURPOSE WITH SUFFICIENT DETAIL TO DISTINGUISH IT FROM ALL OTHER CIRCUITS, USE OWNER'S FINAL SPACE DESIGNATIONS. 9. MOUNT TOP OF TRIM AT +90" AFF. 262726 - WIRING DEVICES 1. RECEPTACLES - COMPLY WITH NEMA WD 1 AND WD 6, AND UL 498, 125V, 20A RATED. 2. TOGGLE SWITCHES - COMPLY WITH NEMA WD 1, UL 20, AND FS W-S-896. 3. PROVIDE WHITE DEVICES WITH .035" THICK SATIN FINISHED TYPE 302 STAINLESS STEEL COVERPLATES IN FINISHED SPACES. PROVIDE CASEALUMINUM COVERPLATES IN WET AND DAMP LOCATIONS. 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS 1. FUSIBLE SWITCHES - TYPE HD, SINGLE THROW, LOCKABLE HANDLE, MECHANICAL TYPE LUGS. 2. NON-FUSIBLE SWITCHES - TYPE HD, SINGLE THROW, LOCKABLE HANDLE, MECHANICAL TYPE LUGS. 3. MCCB - PROVIDE THERMAL MAGNETIC CIRCUIT BREAKER WITH STANDARD TRIP RATINGS AND NUMBER OF POLES, MECHANICAL LUGS AND LISTED FOR INTERRUPTING CAPACITY TO COMPLY WITH AVAILABLE FAULT CURRENT. 4. ENCLOSURE - COMPLY WITH NEMA AB 1, NEMA KS 1, NEMA 250, AND UL 50. 4.1 INDOOR DRY AND CLEAN LOCATIONS - NEMA 250 TYPE 1. 4.2 OUTDOOR LOCATIONS - NEMA 250 TYPE 3R. 4.3 OTHER WET OR DAMP LOCATIONS - NEMA 250 TYPE 4. 265116 - FLUORESCENT INTERIOR LIGHTING 1. COMPLY WITH UL 1598 AND ANSI C81.61. 2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.11, CLASS A SOUND RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR HIGHER, 0.95 POWER FACTOR OR HIGHER. 3. EMERGENCY FLUORESCENT POWER UNIT - INTERNAL TYPE, MODULAR BATTERY- INVERTER TO OPERATED ONE LAMP AT 1100 LUMEN OUTPUT, SEALED NI-CAD BATTERY. 4. LAMPS - 3500 DEGREE K, 20,000 HOURS AVERAGE LIFE, CRI: 85 OR HIGHER. 265119 - LED INTERIOR LIGHTING 1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61. 2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS. 265617 - FLUORESCENT EXTERIOR LIGHTING 1. COMPLY WITH UL 1598 AND ANSI C81.61. 2. PROVIDE ELECTRONIC BALLASTS, UL 935, ANSI C82.11, CLASS A SOUND RATING, 10% THD, 42KHz OPERATING FREQUENCY, BALLAST FACTOR: 0.88 OR HIGHER, 0.95 POWER FACTOR OR HIGHER. 265619 - LED EXTERIOR LIGHTING 1. COMPLY WITH NEMA LE 4 AND ANSI C79.1 AND C81.61. 2. MINIMUM CRI: 80, CCT: 3000 DEGREES K, L70 LAMP LIFE: 50,000 HOURS. 283111 - FIRE ALARM 1. SYSTEM DESCRIPTION 1.1 PROVIDE ALL COMPONENTS COMPATIBLE WITH AN OPERATE AS AN EXTENSION OF EXISTING SYSTEM. PROVIDE MANUFACTURER'S CERTIFICATION THAT ALL COMPONENTS PROVIDED HAVE BEEN TESTED AS, AND WILL OPERATE AS, A SYSTEM. 1.2 NON-CODED UL-CERTIFIED ADDRESSABLE SYSTEM WITH MULTIPLEXED SIGNAL TRANSMISSION AND VOICE HORN/STROBE EVACUATION. 1.3 ALL COMPONENTS LISTED FOR USE WITH SELECTED SYSTEM, LISTED AND LABELED AS DEFINED IN NFPA 70 BY QUALIFIED TESTING AGENCY. 2. FIRE ALARM CONTROL UNIT 2.1 FIELD PROGRAMMABLE, MICROPROCESSOR BASED, MODULAR, POWER LIMITED DESIGN WITH ELECTRONIC MODULES, COMPLY WITH UL 864. 2.2 ADDRESSABLE INITIATION DEVICE CIRCUITS. 2.3 ADDRESSABLE CONTROL CIRCUITS. 2.4 ALPHANUMERIC DISPLAY AND SYSTEM CONTROLS: DISPLAY ALARM, SUPERVISORY, AND COMPONENT STATUS MESSAGES AND THE PROGRAMMING AND CONTROL MENU. 2.5 PRIMARY POWER: 24VDC OBTAINED FROM 120V AC SERVICE AND POWER SUPPLY MODULE. 2.6 SECONDARY POWER: 24VDC SUPPLY SYSTEM WITH SEALED LEAD CALCIUM BATTERIES, AUTOMATIC BATTERY CHARGER, AND AUTOMATIC TRANSFER SWITCH. 3. MANUAL FIRE ALARM BOXES 3.1 COMPLY WITH UL 38, FINISH IN RED WITH MOLDED RAISED LETTER OPERATING INSTRUCTIONS IN CONTRASTING COLOR. 3.2 DOUBLE ACTION MECHANISM, PULL LEVER TYPE WITH INTEGRAL ADDRESSABLE MODULE. 3.3 STATION RESET: KEY OR WRENCH OPERATED SWITCH. 4. SYSTEM SMOKE DETECTORS 4.1 COMPLY WITH UL 268, OPERATING AT 24V DC NOMINAL WITH INTEGRAL ADDRESSABLE MODULE. 5. HEAT DETECTORS 5.1 COMPLY WITH UL 521. 5.2 ACTUATED BY EITHER FIXED TEMPERATURE OF 135 DEGREES F OR RATE OF RISE THAT EXCEEDS 15 DEGREES F PER MINUTE. 6. NOTIFICATION APPLIANCES 6.1 INDIVIDUALLY ADDRESSED AND CONNECTED TO A SIGNALING LINE CIRCUIT. 6.2 HORNS: COMPLY WITH UL 464, PRODUCE SOUND PRESSURE LEVEL OF 90dBA MEASURED 10 FEET FROM HORN, USING CODED SIGNAL PRESCRIBED IN UL 464 TEST PROTOCOL. 6.3 VISIBLE NOTIFICATION APPLIANCES: XENON STROBE LIGHTS COMPLY WITH UL 1971 WITH CLEAR NOMINAL WHITE POLYCARBONATE LENS. 6.3.1 LIGHT OUTPUT: 15/30/75/110 DC SELECTABLE IN THE FIELD. 6.3.2 FLASHING IN TEMPORAL PATTERN, SYNCHRONIZED WITH OTHER UNITS. 6.4 VOICE/TONE NOTIFICATION APPLIANCES 6.4.1 COMPLY WITH UL 1480. 6.4.2 HIGH RANGE UNITS: RATED 2 TO 15 W. 6.4.3 LOW RANGE UNITS: RATED 1 TO 2 W. 7. MAGNETIC DOOR HOLDERS 7.1 ELECTROMAGNETS REQUIRE MAXIMUM 3W TO DEVELOP 25 LBF HOLDING FORCE. 8. REMOTE ANNUNCIATOR 8.1 MATCH FUNCTIONS TO FIRE ALARM CONTROL UNIT FOR ALARM, SUPERVISORY, AND TROUBLE INDICATIONS, AND MANUAL SWITCHING FUNCTIONS. 8.2 ALPHANUMERIC DISPLAY AND LED INDICATING LIGHTS. 9. SUBMITTAL REQUIREMENTS 9.1 SUBMIT SHOP DRAWINGS AND PRODUCT DATA TO THE AUTHORITY HAVING JURISDICTION FOR APPROVAL. SUBMIT APPROVED DRAWINGS AND DATA TO ARCHITECT. 9.2 SHOP DRAWINGS AND PRODUCT DATA SHALL BE PREPARED BY PERSONS TRAINED AND CERTIFIED BY MANUFACTURER IN FIRE ALARM SYSTEM DESIGN AND LICENSED OR CERTIFIED BY AUTHORITIES HAVING JURISDICTION. 9.3 PRODUCT DATA SHALL INCLUDE: 9.3.1 CONSTRUCTION DETAIL, MATERIAL DESCRIPTIONS, DIMENSIONS, PROFILES, AND FINISHES. 9.3.1 RATED CAPACIEITES, OPERATING CHARACTERISTICS, AND ELECTRICAL CHARACTERISTICS. 9.4 SHOP DRAWINGS SHALL INCLUDE: 9.4.1 PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHEMENTS TO OTHER WORK. 9.4.2 DETAILS OF EQUIPMENT ASSEMBLIES AND SUPPORT REQUIREMENTS. 9.4.3 VOLTAGE DROP CALCULATIONS FOR NOTIFICATION APPLIANCE CIRCUITS. 9.4.4 BATTERY SIZE CALCULATIONS 9.4.5 STATEMENT FROM MANUFACTURER THAT ALL EQUIPMENT AND COMPONENTS HAVE BEEN TESTED AS A SYSTEM AND COMPLY WITH NFPA 72. PROJECT INFORMATION PROJECT DESCRIPTION: [ KEEP IT VERY BRIEF ] APPLICABLE CODES: VIRGINIA UNIFORM STATEWIDE BUILDING CODE, 2012 EDITION NATIONAL ELECTRICAL DOCE, 2011 EDITION INTERNATIONAL ENERGY CONSERVATION CODE, 2012 EDITION YEAR CONSTRUCTED: [ YYYY ] EXISTING USE GROUP: [ USE GROUP ] CONSTRUCTION CLASSIFICATION: [ CLASSIFICATION ] NUMBER OF STORIES: [ # ] BUILDING HEIGHT" [ __'-__" ] PROJECT AREA: [ ____ SQFT ] TOTAL BUILDING AREA" [ ____ SQFT ] PROJECT: [ NOT IN A FLOOD PLAIN ] FIRE RESISTANCE RATING: [ NO FIRE PENETRATIONS ] OCCUPANCY: [ # ] CHANGE OF USE: [ YES ] [ NO ] 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. DRAWING NUMBER E001 E101 E102 E111 E112 E121 E122 E131 E132 E401 E501 E601 DRAWING TITLE LEGEND AND SPECIFICATIONS FIRST FLOOR PLAN DEMOLITION SECOND FLOOR PLAN DEMOLITION FIRST FLOOR PLAN LIGHTING SECOND FLOOR PLAN LIGHTING FIRST FLOOR PLAN POWER SECOND FLOOR PLAN POWER FIRST FLOOR PLAN FIRE ALARM SECOND FLOOR PLAN FIRE ALARM LARGE SCALE PLANS DETAILS SCHEDULES AND DIAGRAMS ELECTRICAL DRAWING LIST 1P SINGLE POLE 2P DOUBLE POLE 3P THREE POLE 1PH SINGLE PHASE 3PH THREE PHASE A AMPERES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AMP AMPERE AUTO AUTOMATIC A/V AUDIO / VISUAL AWG AMERICAN WIRE GAUGE BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE C CONDUIT CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CF COMPACT FLUORESCENT CKT CIRCUIT C/T CURRENT TRANSFORMER CU COPPER DEMO DEMOLITION DISC DISCONNECT ELEC ELECTRICAL ELTG EXTERIOR LIGHTING EM EMERGENCY EQ EQUIPMENT FA FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FC FOOT CANDLE FT FEET FVNR FULL VOLTAGE NON-REVERSING G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTING GFI GROUND FAULT INTERRUPTING GND GROUND HP HORSE POWER IAW IN ACCORDANCE WITH ILTG INTERIOR LIGHTING IN INCHES KCMIL KILO CIRCULAR MILLS KVA KILO VOLT AMPS KW KILO WATTS KWH KILO WATT HOURS LED LIGHT EMITTING DIODE LTG LIGHTING LTS LIGHTS MCC MOTOR CONTROL CENTER MISC MISCELLANEOUS MTD MOUNTED MTR MOTOR N NEUTRAL NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NO. NUMBER P/BD PANELBOARD PR PRESENT TO REMAIN PRI PRIMARY PVC POLYVINYL CHLORIDE PWR POWER RCPT RECEPTACLE RL RELOCATED SEC SECURITY SW SWITCH SWBD SWITCH BOARD TELECOM TELECOMMUNICATIONS TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS W/ WITH XFER TRANSFER XFMR TRANSFORMER ABBREVIATIONS S S J SF SF T C C S SD H TS FS PS M C F F F KP CR M PC M M G S H S H S H PC I I I S H RATED WALL LEGEND SYMBOL DESCRIPTION NON-RATED PARTITION NON-RATED SMOKE RESISTIVE PARTITION 1 HOUR FIRE BARRIER 1 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 2 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 3 HOUR SMOKE COMPARTMENT BARRIER CK ML ES EL 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:08:58 AM LEGEND, SPECS, FIXTURE SCHEDULE & UL DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 11/03/16