Loading...
HomeMy WebLinkAboutB16-0266_E101_1478902290.pdfSD F F F F FFF F SD F J F F SB SB SB SB F J F D D Dv D Dv D v DDv DD D D D DDDDDD J F F F K KKJ KTTT epo F F K F F F F J MENS ROOM WOMENS ROOM MAINTENANCE FITNESS AREA N.I.C. N.I.C. TIMBER FRAME ENTRY STRUCTURE AND ROOF TO BE REMOVED 26.1 26.10 26.11 TYPICAL 26.12 26.12 26.2 26.2 26.13 26.3 26.14 26.3 26.14 26.12 26.2 26.3 26.14 EXISTING TO REMAIN PANEL 26.3 26.14 26.12 26.3 26.12 26.14 RECEPTION DESK TO BE REMOVED 26.3 26.3 26.12 26.12 26.15 26.15 26.4 26.3 26.3 26.15 26.16 BENCH SEATING TO BE REMOVED 26.3 26.17 26.3 26.14 26.12 26.3 26.14 26.3 26.14 26.12 RECEPTION DESK TO BE REMOVED 26.3 26.14 26.12 26.5 26.5 26.18 26.12 THERAPY / SPA 26.5 26.12 26.18 26.5 26.18 26.12 26.5 26.18 26.12 26.5 26.5 26.12 26.12 26.15 26.3 26.19 26.19 26.20 26.20 HOT TUB TO BE REMOVED 26.3 26.2 26.21 26.22 26.3 26.14 26.12 SOFFIT TO BE REMOVED 26.5 26.15 26.2 26.12 26.15 26.5 TYPICAL 26.24 26.23 26.6 COVE MOUNTED SPOT LIGHTING TYPICAL 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:02 AM DEMOLITION PLAN - 1st FLOOR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E101 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" 6APOWER DEMOLITION PLAN - 1st FLOOR KEYNOTES 26.19 DISCONNECT AND REMOVE SAUNA STEAM GENERATOR AND ALL ASSOCIATED EQUIPMENT BACK TO SOURCE. CIRCUIT TO BE REUSED FOR NEW WORK. 26.20 DISCONNECT AND REMOVE HOT TUB PUMPS, ASSOCIATED EQUIPMENT AND CONTROLS. CIRCUITS TO BE EXTENDED REUSED FOR NEW HOT TUB LOCATION. 26.21 DISCONNECT AND REMOVE HVAC DISCONNECTS FOR RELOCATION. 26.22 DISCONNECT AND REMOVE ABANDONED MISCELLANEOUS ELECTRICAL DEVICES / CONDUIT/EQUIPMENT AND WIRE BACK TO SOURCE. 26.23 DISCONNECT AND REMOVE AHU FOR REPLACEMENT WITH NEW UNIT. 26.24 DISCONNECT AND REMOVE OUTDOOR CONDENSING UNITS, DISCONNECTS AND WIRE BACK TO SOURCE. CIRCUITS TO BE REUSED FOR NEW VAV BOXES. TYPICAL OF (3) 26.1 DISCONNECT AND REMOVE LIGHTING, CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW UNDER CANOPY LIGHTING. 26.2 DISCONNECT AND REMOVE LIGHTING. CIRCUIT TO BE REUSED FOR NEW LIGHTING IN SAME AREA. 26.3 DISCONNECT AND REMOVE ALL LIGHTING, SWITCHING AND WIRE BACK TO SOURCE. 26.4 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION ON NEW WALL. 26.5 DISCONNECT AND REMOVE LIGHTING AND SWITCHING. REMOVE WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW LIGHTING WORK IN THIS SAME AREA. 26.6 DISCONNECT AND REMOVE ALL WALL MOUNTED SCONCES, RECESSED LIGHTING ABOVE GUESTROOM DOORS AND IN VENDING AREA, ANY ASSOCIATED CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW LED RECESSED LIGHTING ALONG GUESTROOM CORRIDOR. 26.10 DISCONNECT AND REMOVE RECEPTACLE, CONDUIT AND WIRE BACK TO REUSABLE LOCATION. 26.11 DISCONNECT AND REMOVE INFRARED HEATER AND WIRE BACK TO REUSABLE LOCATION. HEATER AND CIRCUIT TO BE REUSED FOR NEW VALET LOCATION. 26.12 DISCONNECT AND REMOVE FIRE ALARM DEVICES AND WIRE BACK TO REUSABLE LOCATION. DEVICES TO BE REUSED FOR NEW WORK. 26.13 DISCONNECT AND REMOVE PANELBOARD AND FEEDER BACK TO SOURCE. LABEL BREAKER OR DISCONNECT AS SPARE. 26.14 DISCONNECT AND REMOVE ALL RECEPTACLES, DATA OUTLETS AND WIRE BACK TO SOURCE. 26.15 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO SOURCE. 26.16 DISCONNECT AND REMOVE RECESSED FLOOR BOXES, CONDUIT AND WIRE BACK TO SOURCE. 26.17 DISCONNECT FIRE PLACE FOR DEMOLITION / REMOVAL. 26.18 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW WORK IN THIS SAME AREA. GENERAL PLAN NOTES 1. REMOVE ALL SPEAKERS, SWITCHING AND ALL ASSOCIATED SOUND SYSTEM EQUIPMENT FROM THERAPY / SPA AND RETURN TO OWNER FOR REUSE IN NEW THERAPY / SPA LOCATION. 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 11/03/16