Loading...
HomeMy WebLinkAboutB16-0266_E121_1502723340.pdfREF Ref. Under Counter SB SB SB SB J J J J MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 RETAIL 109 OFFICE 3 130 OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 N.I.C. N.I.C. W EMPLOYEE LOCKER ROOM 137 PR PR PR E401b 4A E402 4A E403 4A E404 4A E404 6C E405 6A E406 4A E406 3D E402 4C E402 6C LD B RELOCATED 100A PANEL 26.45 TYPICAL OFFICE 2 131 LLD +48" 26.105 TO EXISTING BALLROOM RECEPTACLE 26.3926.39 LLF LLF- 1,3 LLF- 5,7 LLF- 9,11 LLF- 13,15 26.108 26.107 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/31/2017 9:13:57 AM 1st FLOOR PLAN - POWER AND COMMUNICATIONS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E121 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a 6APOWER AND COMMUNICATIONS PLAN - 1st FLOOR KEYNOTES 26.39 PROVIDE MATCHING AIC 400A, 3P CIRCUIT BREAKER IN AVAILABLE 3000A SWITCHBOARD SPACE FOR NEW 400A PANEL 'LLF' TO BE LOCATED IN NEW STORAGE AREA AT MEETING ROOM. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.105 PROVIDE RECEPTACLE AND DATA OUTLET FOR DIGITAL EVENT READER. EXTEND RECEPTACLE TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. COORDINATE FINAL LOCATION AND REQUIREMENTS WITH APPROVED PROVIDER PRIOR TO ROUGH-IN. 26.107 PROVIDE 400A, 3วพ, 42P PANEL. EXTEND AND CONNECT TO 3P BREAKER IN SWITCHGEAR WITH (4)#500KCMIL, (1)#2GND - 3 1/2"C. CONTRACTOR TO FIELD COORDINATE PANEL LOCATION SO THAT PANEL CAN BE USED FOR FUTURE DEVELOPMENT OF UPSTAIRS LODGING. 26.108 PROVIDE JUNCTION BOX OR SINGLE POINT CONNECTION FOR OUTDOOR INFRARED HEATERS. TYPICAL OF (4). 1 8/25/2016 FOR CONSTRUCTION SET 3 10/07/2016 ASI #1 5 12/07/2016 RFI #55 9 7/21/17 CCD-05 07/31/2017 08/14/17