Loading...
HomeMy WebLinkAboutB16-0266_E430_1502723340.pdfF F J SD H F J FSDF J F SD J F F J F F J SD F F SD F F J F F SD SD F F J 26.81 26.82 26.84 26.84 26.8526.85 26.81 26.86 26.82 26.91 26.93 26.94 26.92 26.95 26.96 26.90 26.96 K2 202 26.81 26.82 26.84 26.84 26.8526.85 26.81 26.87 26.88 26.86 26.82 K2 202 26.91 26.92 26.93 26.94 26.95 26.96 RELOCATED FAN BY OTHERS 26.96 26.90 26.81 26.82 26.84 26.86 26.8526.85 26.84 26.81 26.91 26.92 26.93 26.94 26.95 26.96 26.90 26.81 26.82 26.86 26.81 26.8526.85 26.84 26.84 26.91 26.93 26.95 26.94 26.96 26.90 26.92 QA 306 26.81 26.82 26.84 26.81 26.82 26.86 26.8526.85 26.84 QA 306 26.95 26.94 26.91 26.92 26.93 26.96 26.96 26.90 QA 406 26.81 26.81 26.82 26.84 26.86 26.8526.85 26.84 QA 406 26.91 26.92 26.93 26.94 26.96 26.95 26.96 26.90 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/31/2017 9:14:27 AM ENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E430 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E102 1AGUESTROOM DEMOLITION - KA (204) SCALE: 1/4" = 1'-0" 2AGUESTROOM NEW WORK - KA (204) SCALE: 1/4" = 1'-0"3AGUESTROOM DEMOLITION - K (202) SCALE: 1/4" = 1'-0" DRAWING REF: E102 4AGUESTROOM NEW WORK - K (202) SCALE: 1/4" = 1'-0" DRAWING REF: E102 5AGUESTROOM DEMOLITION - KARI (237) SCALE: 1/4" = 1'-0" 6AGUESTROOM NEW WORK - KARI (237) KEYNOTES 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.87 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE LOCATION. LIGHTING FIXTURE AND CIRCUIT TO BE REUSED. 26.88 DISCONNECT AND REMOVE RECESSED FAN. FAN TO BE REUSED AT NEW LOCATION IN SAME AREA. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT. SCALE: 1/4" = 1'-0" 1CGUESTROOM DEMOLITION - QQARI (235) SCALE: 1/4" = 1'-0" DRAWING REF: E102 2CGUESTROOM NEW WORK - QQARI (235) SCALE: 1/4" = 1'-0" DRAWING REF: E102 3CGUESTROOM DEMOLITION - QA RM (306) SCALE: 1/4" = 1'-0" 4CGUESTROOM NEW WORK - QA RM (306) SCALE: 1/4" = 1'-0" DRAWING REF: E104 5CGUESTROOM DEMOLITION - QA (406) SCALE: 1/4" = 1'-0" 6CGUESTROOM NEW WORK - QA (406) 9 7/21/17 CCD-05 07/31/2017 08/14/17