HomeMy WebLinkAboutB16-0266_E431_1478900227.pdfF
SD
3
3
SD
F
J
J
REF
J
REF
J
F SD
REF
SD
F
J
KCON
412
Q
410
26.81
26.81
26.8526.85
26.86
26.8226.82
KCON
412
Q
410
26.98
26.98
26.93
26.92
26.90
KCON+
512
26.86
KCON+
512
26.90
KMR
208
26.86
26.85
26.86
26.85
26.8426.84
26.81
KMR
208
26.94
26.9526.95
26.100
+32"
26.90
26.93
QQMR
205
26.86
26.81
26.8426.84
26.8526.85
26.86
QQMR
205
26.94
26.91
26.9526.95
26.90
26.86
26.81
26.84
26.8426.84
26.8226.82
26.8526.85
26.86
26.94 26.91
+32"
26.96 26.9526.95
26.100
26.90
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
11:09:51 AM
ENLARGED
GUESTROOM PLANS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
E431
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH
NEW.
26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE
BACK TO REUSABLE LOCATION.
26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE
LOCATION. CIRCUIT TO BE REUSED.
26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING
BACK TO SOURCE.
26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO
BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF
GUESTROOMS.
26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND
CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT.
VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO
ROUGH-IN. TYPICAL OF GUESTROOMS.
26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND
RECONNECT.
26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE
FROM DEMOLITION AND RECONNECT.
26.93 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING,
FAN AND BACK-LIT MIRROR SWITCH LEG. MAKE ALL FINAL CONNECTIONS.
26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO
DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON)
HALL CIRCUIT.
26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT.
26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT.
26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF.
EXTEND AND RECONNECT AS 3-WAY.
26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE
CIRCUIT AND CONNECT.
SCALE: 1/4" = 1'-0" DRAWING REF: E1231GUESTROOM DEMO - KING CONDO (412) & QA
SCALE: 1/4" = 1'-0"
2GUESTROOM NEW WORK - KING CONDO (412) & KA
SCALE: 1/4" = 1'-0" DRAWING REF: E123 3GUESTROOM DEMOLITION - KING CONDO LOFT (512)
SCALE: 1/4" = 1'-0" DRAWING REF: E123 4GUESTROOM NEW WORK - KING CONDO LOFT (512)
SCALE: 1/4" = 1'-0" DRAWING REF: E1225DEMO - KING MODEL ROOM (208)
SCALE:
1/4" = 1'-0"6NEW WORK - KING MODEL ROOM (208)
SCALE: 1/4" = 1'-0" DRAWING REF: E1227DEMOLITION - QQ MODEL ROOM (205)
SCALE: 1/4" = 1'-0"
8NEW WORK - QQ MODEL ROOM (205)
SCALE: 1/4" = 1'-0" DRAWING REF: E122 9GUESTROOM DEMOLITION - KS (301)
SCALE: 1/4" = 1'-0" DRAWING REF: E122 10GUESTROOM NEW WORK - KS (301)
07/11/2016
P.O. BOX 400, RICHMOND, VA 23218-0400
®
08/16/16