Loading...
HomeMy WebLinkAboutB16-0266_E431_1478902331.pdfF SD 3 3 SD F J J REF J REF J F SD REF SD F J KCON 412 Q 410 26.81 26.81 26.8526.85 26.86 26.8226.82 KCON 412 Q 410 26.98 26.98 26.93 26.92 26.90 KCON+ 512 26.86 KCON+ 512 26.90 KMR 208 26.86 26.85 26.86 26.85 26.8426.84 26.81 KMR 208 26.94 26.9526.95 26.100 +32" 26.90 26.93 QQMR 205 26.86 26.81 26.8426.84 26.8526.85 26.86 QQMR 205 26.94 26.91 26.9526.95 26.90 26.86 26.81 26.84 26.8426.84 26.8226.82 26.8526.85 26.86 26.94 26.91 +32" 26.96 26.9526.95 26.100 26.90 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:51 AM ENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E431 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF GUESTROOMS. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING, FAN AND BACK-LIT MIRROR SWITCH LEG. MAKE ALL FINAL CONNECTIONS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT. 26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF. EXTEND AND RECONNECT AS 3-WAY. 26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. SCALE: 1/4" = 1'-0" DRAWING REF: E1231GUESTROOM DEMO - KING CONDO (412) & QA SCALE: 1/4" = 1'-0" 2GUESTROOM NEW WORK - KING CONDO (412) & KA SCALE: 1/4" = 1'-0" DRAWING REF: E123 3GUESTROOM DEMOLITION - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E123 4GUESTROOM NEW WORK - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E1225DEMO - KING MODEL ROOM (208) SCALE: 1/4" = 1'-0"6NEW WORK - KING MODEL ROOM (208) SCALE: 1/4" = 1'-0" DRAWING REF: E1227DEMOLITION - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0" 8NEW WORK - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0" DRAWING REF: E122 9GUESTROOM DEMOLITION - KS (301) SCALE: 1/4" = 1'-0" DRAWING REF: E122 10GUESTROOM NEW WORK - KS (301) 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 11/03/16