Loading...
HomeMy WebLinkAboutB16-0266_E431_1502723401.pdfDW REF. F SD DW REF. 3 3 SD FJ J REF J J F SD REF SD F J KCONL 412 Q1 410 26.81 26.81 26.85 26.85 26.86 26.8226.82 KCONL 412 Q1 410 26.98 26.98 26.93 26.92 26.90 26.96 KCONL+ 512 26.86 KCONL+ 512 26.90 K1L 208 26.86 26.85 26.86 26.85 26.8426.84 26.81 K1L 208 26.94 26.9526.95 26.100 +32" 26.90 26.93 QQ1L 205 26.86 26.81 26.8426.84 26.8526.85 26.86 QQ1L 205 26.94 26.91 26.90 26.95 26.86 26.81 26.84 26.8426.84 26.8226.82 26.8526.85 26.86 26.94 26.91 +32" 26.96 26.9526.95 26.100 26.90 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/31/2017 9:14:36 AM ENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E431 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT. 26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF. EXTEND AND RECONNECT AS 3-WAY. 26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. SCALE: 1/4" = 1'-0" DRAWING REF: E104 1AGUESTROOM DEMO - KING CONDO (412) & QA SCALE: 1/4" = 1'-0" 3AGUESTROOM NEW WORK - KING CONDO (412) & KA SCALE: 1/4" = 1'-0" DRAWING REF: E1044AGUESTROOM DEMOLITION - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E104 6AGUESTROOM NEW WORK - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E1021CDEMO - KING MODEL ROOM (208) SCALE: 1/4" = 1'-0" 2CNEW WORK - KING MODEL ROOM (208) SCALE: 1/4" = 1'-0" 3CDEMOLITION - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0" 4CNEW WORK - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0" DRAWING REF: E1025CGUESTROOM DEMOLITION - KS (301) SCALE: 1/4" = 1'-0" 6CGUESTROOM NEW WORK - KS (301) 9 7/21/17 CCD-05 07/31/2017 08/14/17