HomeMy WebLinkAboutB16-0266_E433_1498075740.pdfDW
J
DW
3
J J 3
J
KCCON
401
26.86
26.81
TYPICAL
26.84
26.81
26.81
26.84
26.86
KCCON
401
26.94
5
E433
+39"
MOUNT HORIZONTAL
ON NEW WALL
26.91
26.104
26.92
26.90
26.93
TO REPLACEMENT
LIGHTING ABOVE
26.98
K+
501
26.79
26.78
26.86
26.81
26.81
K+
501
26.98
26.91
26.90
26.103
05_FOURTH FLOOR
131' - 10"
06_TOP OF PLATE-2
140' - 2"
05_FOURTH
FLOOR
131'
- 10"
06_TOP
OF PLATE-2
140' - 2"
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
11:09:55 AM
ENLARGED
GUESTROOM PLANS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
E433
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
KEYNOTES
26.78 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES AND WIRE BACK TO
SOURCE.
26.79 DISCONNECT AND REMOVE SCONCE AS ONE FOR ONE REPLACEMENT.
26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH
NEW.
26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE
LOCATION. CIRCUIT TO BE REUSED.
26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO
BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF
GUESTROOMS.
26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND
CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT.
VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO
ROUGH-IN. TYPICAL OF GUESTROOMS.
26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND
RECONNECT.
26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE
FROM DEMOLITION AND RECONNECT.
26.93 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING,
FAN AND BACK-LIT MIRROR SWITCH LEG. MAKE ALL FINAL CONNECTIONS.
26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO
DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON)
HALL CIRCUIT.
26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF.
EXTEND AND RECONNECT AS 3-WAY.
26.103 INSTALL NEW SCONCE SUPPLIED BY OTHERS. MAKE FINAL CONNECTIONS.
26.104 PROVIDE BACKBOX AT 12" AFF AND EXTEND ORIGINAL DISH MACHINE CIRCUIT.
RECONNECT MACHINE.
SCALE: 1/4" = 1'-0" DRAWING REF: E123
1GUESTROOM DEMOLITION - KING CORNER (401)
SCALE: 1/4" = 1'-0" 2GUESTROOM NEW WORK - KING CORNER (401)
SCALE: 1/4" = 1'-0" DRAWING REF: E123
3GUESTROOM DEMOLITION - KING CORNER LOFT (501)
SCALE: 1/4" = 1'-0" 4GUESTROOM NEW WORK - KING CORNER LOFT (501)
SCALE: 1/4" = 1'-0" DRAWING REF: E433 5ENLARGED KITCHEN AREA DETAIL
07/11/2016
P.O. BOX 400, RICHMOND, VA 23218-0400
®
06/21/17