Loading...
HomeMy WebLinkAboutB16-0266_E433_1502723400.pdfDW J DW 3 J J 3 J KCCON 401 26.86 26.81 TYPICAL 26.84 26.81 26.81 26.84 26.86 KCCON 401 26.94 5A E433 +39" MOUNT HORIZONTAL ON NEW WALL 26.91 26.104 26.92 26.90 26.93 TO REPLACEMENT LIGHTING ABOVE 26.98 KCCON+ 501 26.79 26.78 26.86 26.81 26.81 KCCON+ 501 26.98 26.91 26.90 26.103 S3 4TH FLOOR 131' - 10" 5TH FLOOR 140' - 2" 05_FOURTH FLOOR 131' - 10" 06_TOP OF PLATE-2 140' - 2" 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/31/2017 9:14:50 AM ENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E433 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.78 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES AND WIRE BACK TO SOURCE. 26.79 DISCONNECT AND REMOVE SCONCE AS ONE FOR ONE REPLACEMENT. 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF. EXTEND AND RECONNECT AS 3-WAY. 26.103 INSTALL NEW SCONCE SUPPLIED BY OTHERS. MAKE FINAL CONNECTIONS. 26.104 PROVIDE BACKBOX AT 12" AFF AND EXTEND ORIGINAL DISH MACHINE CIRCUIT. RECONNECT MACHINE. SCALE: 1/4" = 1'-0" DRAWING REF: E104 2AGUESTROOM DEMOLITION - KING CORNER (401) SCALE: 1/4" = 1'-0" 4AGUESTROOM NEW WORK - KING CORNER (401) SCALE: 1/4" = 1'-0" DRAWING REF: E104 3CGUESTROOM DEMOLITION - KING CORNER LOFT (501) SCALE: 1/4" = 1'-0" 6CGUESTROOM NEW WORK - KING CORNER LOFT (501) SCALE: 1/4" = 1'-0" DRAWING REF: E433 5AENLARGED KITCHEN AREA DETAIL 9 7/21/17 CCD-05 07/31/2017 08/14/17