HomeMy WebLinkAboutB16-0266_E434_1502723398.pdfJ
J
H
F
SD KAR
203
26.81
26.81
26.84
26.8526.85
26.86
26.86
KAR
203
26.91
26.93
26.95
+32"
26.100
26.99
26.90
26.89
+72"
26.84
26.84
PR
RELOCATED
LIGHTING
PR
PR
PR
+32"
PROVIDE NEW
DATA OUTLET
26.92
26.9526.95
26.93
26.100
26.95
26.95
PROVIDE NEW
DATA OUTLET
26.90
26.80
26.83
26.87
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
7/31/2017
9:14:55 AM
ENLARGED
GUESTROOM PLANS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/16 -
CONSTRUCTION
DOCUMENTS
E434
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0" DRAWING REF: E102
1ADEMOLITION - KA DECOM (203)
SCALE: 1/4" = 1'-0"
2ANEW WORK - KA DECOM (203)
KEYNOTES
26.99 PROVIDE RECEPTACLE AT 18" AFF. EXTEND TO NEAREST RECEPTACLE CIRCUIT
AND CONNECT.
26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE
CIRCUIT AND CONNECT.
26.80 DISCONNECT AND REMOVE FIRE ALARM DEVICES. REMOVE WIRE BACK TO
REUSABLE LOCATION.
26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH
NEW.
26.83 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE
LOCATION. CIRCUIT TO BE REUSED FOR NEW LIGHTING.
26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE
LOCATION. CIRCUIT TO BE REUSED.
26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING
BACK TO SOURCE.
26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO
BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL
GUESTROOMS.
26.87 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE
LOCATION. LIGHTING FIXTURE AND CIRCUIT TO BE REUSED.
26.89 DISCONNECT AND REMOVE RECEPTACLE, JUNCTION BOX AND WIRE BACK TO
SOURCE.
26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND
CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT.
VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO
ROUGH-IN. TYPICAL OF ALL GUESTROOMS.
26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND
RECONNECT.
26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE
FROM DEMOLITION AND RECONNECT.
26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE
LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE
SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL
GUESTROOMS.
26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT.
SCALE: 1/4" = 1'-0"
4A2nd FL LAUNDRY DEMO - (206)
SCALE: 1/4" = 1'-0" 5AGUESTROOM NEW WORK - K (206)
SCALE: 1/4" = 1'-0" DRAWING REF: E102 3A2nd FL LAUNDRY LIGHTING DEMO - (206)
LAUNDRY TO BE RETURNED TO GUESTROOM
LAUNDRY TO BE RETURNED TO GUESTROOM
9 7/21/17 CCD-05
07/31/2017
08/14/17