HomeMy WebLinkAboutB16-0266_M001_1478900256.pdfHOT WATER FLOW METER WITH BALANCING COCK THERMOMETER SUPPLY HOT WATER RETURN THREE-WAY AUTOMATIC CONTROL VALVE TERMINAL UNIT HOT WATER COIL CONCEALED REGULATOR KIT CEILING DIFFUSER RIGID DUCTWORK FLEXIBLE DUCTWORK SCREWS AND WIRE (50'-0" RACK & PINION FLEXIBLE CASING MAXIMUM) OPERATOR ADJUSTABLE PRIOR TO INSTALLATION. 1) SPANNER WRENCH ROUND DAMPER COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT COVER PLATE NOTE: INDOOR AIR HANDLING UNIT SCHEDULE DESIGNATION AREA SERVED NOTES MODEL MANUFACTURER SUPPLY AIR FLOW RATE OUTDOOR AIR FLOW RATE EXTERNAL STATIC PRESSURE MOTOR SIZE FAN DRIVE SUPPLY FAN DX COOLING °F W.B. °F D.B. °F W.B. °F D.B. ENTERING AIR CONDITIONS MAX LEAVING AIR CONDITIONS EER MIN TOTAL CAPACITY MIN SENSIBLE CAPACITY ROWS HOT WATER HEATING COIL ENTERING AIR TEMP °F D.B. MIN LEAVING AIR TEMP °F D.B. MIN TOTAL CAPACITY GPM MCA VOLT/PH ELECTRICAL AHU-1 BACK OF HOUSE 3,800 RCC154/HCC154 ADDISON 915 CFM 2.25" 5 HP BELT 52.9 53.2 66.1 77.0 156.1 MBH 100.5 MBH 10.7 4 55 85 211 MBH 12.6 1, 2, 3, 4, 5, 6, 7 NOTES: 1. PROVIDE MICROPROCESSOR BASED BACNET CONTROLLER. 2. PROVIDE FACTORY NON-FUSED DISCONNECT. 3. COOLING CAPACITY BASED ON 95°F AMBIENT AIR AND 8,000 FEET ELEVATION. 4. HEATING CAPACITY BASED ON 180°F HEATING WATER. 5. PROVIDE 2" MERV 11 AIR FILTERS AND FILTER DIFFERENTIAL PRESSURE SWITCH. 6. PROVIDE SINGLE POINT POWER CONNECTION. 7. PROVIDE CORRESPONDING OUTDOOR CONDENSING UNIT WITH SEPARATE ELECTRICAL DISCONNECT AND PRE-CHARGED REFRIGERANT LINE KIT. 57.6 208 / 3 VOLTS/PHASE DESIGNATION MODEL TYPE SIZE (FEET) GPM %EFF. HP RPM HEAD MOTOR NOTES SERVICE IMPELLER (INCHES) RATE FLOW 208/3 P-1 INLINE B & G E-90 25 6 27 1/2 1800 TERMINAL REHEAT SECONDARY LOOP 1AAB 5 NOTES: PUMP SCHEDULE 1 1. PUMP SHALL BE ALL BRONZE CONSTRUCTION AND HAVE 316 STAINLESS STEEL SHAFT. 2. PROVIDE DISCONNECT. 2 DESIGNATION SERVICE TYPE AIR PATTERN FINISH FACE SIZE / FRAME MODEL NECK SIZE AIR DISTRIBUTION DEVICE SCHEDULE ACCESSORIES 1 NOTES AND ACCESSORIES: R-1 GRILLE RETURN TITUS PAR E-1 GRILLE EXHAUST - S-1 TWO WAY COLOR BY ARCH SLOT SUPPLY 48" LENGTH TITUS ML-39 1 3 PAINT VISIBLE PLENUM OR DUCTWORK BEHIND GRILLE FLAT BLACK. TITUS 350 RL SEE PLAN 22x22 ADJUST PATTERN CONTROLLERS AS SHOWN. PROVIDE OPPOSED BLADE DAMPER. SEE PLAN - 3 S-3 HORIZONTAL SUPPLY SEE PLANS / SURFACE TITUS CT 480 LINEAR BAR SEE PLAN 4 PROVIDE MOUNTING FRAME AS REQUIRED FOR INSTALLATION. REFER TO ARCH REFLECTED CEILING PLANS. 3 2 2 3 4 5 4 4 S-4 SUPPLY TITUS 300 RS SEE PLAN 1 2 4 5 2 SLOT, 1 INCH SLOT WIDTH WITH INSULATED PLENUM BOOT. S-2 ROUND SUPPLY 24x24 / SURFACE OR LAY-IN TITUS OMNI PLAQUE FACE SEE PLAN 4 COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH SEE PLANS / SURFACE HORIZONTAL SIDE WALL SEE PLANS / SURFACE 24x24 / SURFACE OR LAY-IN E-2 GRILLE TITUS PAR - 22x22 COLOR BY ARCH 24x24 / SURFACE OR LAY-IN EXHAUST 3 4 ELECTRIC WALL HEATER SCHEDULE LOCATION EWH-1 DESIGNATION BTU/HR CAPACITY PHASE VOLTS/ KW CFM °F E.A.T. AMPS HZ MOTOR MODEL NUMBER MAKE AND NOTES 27,400 8.0 208 / 1 F30522T2DWB VESTIBULE 400 60 38.5 40 NOTES: 1. PROVIDE WALL MOUNT BRACKET. 2. PROVIDE UNIT MOUNTED DISCONNECT SWITCH. 3. PROVIDE BUILT-IN, TAMPER-PROOF THERMOSTAT. 1 2 3 TERMINAL BOX SCHEDULE VAV AIR VALVE DESIGNATION TERMINAL BOX MIN. CFM MAX. CFM INCH DIA. SIZE INLET CFM IN. W.G. STATIC PRESS. MAX. EWT EAT HOT WATER HEATING COIL GPM MAKE MODEL °F NOTES / ACCESSORIES LWT LAT °F °F °F WPD FT WG MAX. 1 85 165 6 170 540 8 160 160 6 335 855 10 85 160 6 130 430 6 145 475 6 VAV-1 220 500 8 0.25 180 0.5 0.3 DESV TITUS 335 755 8 168 152 157 156 167 158 158 152 144 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 91.7 85.8 101.7 99.6 95.4 110.0 100.7 97.3 105.0 0.9 PERFORMANCE BASED ON ACCORDANCE WITH ASHRAE 120, AHRI 880, AND ELEVATION OF 8,000 FEET. 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 SPACE TEMPERATURES ARE BASED ON 76°F COOLING /72°F HEATING DURING OCCUPIED HOURS; 85°F COOLING / 65°F HEATING DURING UNOCCUPIED HOURS. PROVIDE WITH WIRELESS, STAND-ALONE CONTROLLER COMPATIBLE WITH THE AHU AND USING BACNET PROTOCOL. VAV-2 VAV-3 VAV-4 VAV-5 VAV-6 VAV-8 VAV-9 VAV-7 DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS 85 170 160 335 85 130 145 220 335 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 180 180 180 180 180 180 180 180 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 NEW DUCTWORK, PIPING OR EQUIPMENT (SHOWN DARK) EXISTING DUCTWORK, PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING DUCTWORK, PIPING OR EQUIPMENT TO BE REMOVED ACCESS DOOR TURNING VANES DUCT SECTION, SUPPLY DUCT SECTION, RETURN/OUTSIDE AIR MOTORIZED DAMPER DUCT SMOKE DETECTOR AIR FLOW MEASURING SENSOR 12x12 FIRE DAMPER SMOKE DAMPER DUCT SECTION, EXHAUST 12x12 12x12 M F S C CHECK VALVE BUTTERFLY VALVE STEAM PRESSURE REGULATING VALVE STEAM DRIP TRAP ASSEMBLY TEE OFF TOP TEE OFF BOTTOM FLOW CONTROL VALVE DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW MANUAL AIR VENT (SEE DETAIL) AUTOMATIC AIR VENT (SEE DETAIL) CONCENTRIC REDUCER ECCENTRIC REDUCER ELBOW, TURNING DOWN ELBOW, TURNING UP DIFFERENTIAL PRESSURE SWITCH GLOBE VALVE ISOLATION VALVE HOSE BIBB DRAIN VALVE BALL VALVE UNION PLUG VALVE AUTOMATIC VALVE, 3-WAY, PNUEMATIC AUTOMATIC VALVE, 3-WAY, ELECTRIC/ELECTRONIC FLEXIBLE PIPE CONNECTOR AUTOMATIC VALVE, 2-WAY, PNUEMATIC AUTOMATIC VALVE, 2-WAY, ELECTRIC/ELECTRONIC RELIEF VALVE WATER PRESSURE REDUCING VALVE STRAINER PIPE GUIDE PIPE ANCHOR FLOW METER PIPE CAP CARBON DIOXIDE SENSOR (MOUNT 4'-0" A.F.F.) CARBON MONOXIDE SENSOR (MOUNT 4'-0" A.F.F.) POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT DP CO AAV MAV DUCTWORK WITH LINER VOLUME DAMPER TRANSITION, FLAT ON TOP SPLITTER DAMPER SUPPLY AIR DEVICE COUNTERBALANCED BACKDRAFT DAMPER TRANSITION, FLAT ON BOTTOM FOT FOB FLEXIBLE DUCT CONNECTION FLEXIBLE DUCT 12x12 S-1 300 CFM RETURN AIR DEVICE 12x12 R-1 300 CFM EXHAUST AIR DEVICE 12x12 E-1 300 CFM HUMIDITY SENSOR (MOUNT 4'-0" A.F.F.) H THERMOSTAT (MOUNT 4'-0" A.F.F.) T TEMPERATURE SENSOR (MOUNT 4'-0" A.F.F.) TS BDD HOT WATER FLOW DIAGRAM SCALE: NONE FLUE (TYP) TO NEAREST DRAIN (TYP) PRV INLET (TYP) 4" HWS PRV 4" HWR NOTE: EXISTING BOILERS AND MAIN PIPING SHALL CONTINUE TO BE USED TO SUPPLY HEATING HOT WATER TO ALL INDOOR EQUIPMENT. THERE ARE NO CHANGES TO HYDRONIC CONTROLS OR DESIGN TEMPERATURES. EXISTING BOILER2 EXISTING PUMP 3 TO BASEBOARD AND BUILDING HEATING EXISTING AIR SEPARATOR EXISTING SECONDARY LOOP TO ADDITIONAL HYDRONIC HEAT EXCHANGER EXISTING SECONDARY LOOP TO SNOWMELT HEAT EXCHANGER EXISTING SECONDARY LOOP TOSPA HEAT EXCHANGER REMOVE EXISTING SPA HYDRONIC SYSTEM. REUSE MAIN TAP LOCATION FOR NEW TERMINAL UNIT HEATING LOOP. REFER TO NEW LOOP DETAIL THIS SHEET. EXISTING BOILER1 SINGLE DUCT VAV TERMINAL BOX (TYPICAL) NEW REHEAT LOOP HOT WATER FLOW DIAGRAM SCALE: NONE NOTE: EXISTING BOILERS AND MAIN PIPING SHALL BE USED TO SUPPLY HEATING HOT WATER TO ALL NEW VAV BOXES. PROVIDE NEW PIPING AND TAP EXISTING PIPING AS INDICATED ON FLOW DIAGRAM AND ROUTE AS SHOWN ON FLOOR PLANS. NEW PUMP AND THREE WAY VALVE SHALL BE INTEGRATED INTO THE EXISTING HEATING CONTROLS SYSTEM. 1" HWS 1" HWS 3/4" HWS AND HWR UNLESS OTHERWISE NOTED ON FLOOR PLANS BRANCH ISOLATION VALVES, TYPICAL AT EACH TAP FROM MAIN TO TERMINAL UNIT PROVIDE HYDRONIC BRIDGE IF NOT TIED INTO END OF RUN AS SHOWN. 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:05:07 AM LEGEND, DETAILS & SCHEDULES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET M001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL MECHANICAL LEGEND - GENERAL MECHANICAL 1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 2. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 3. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS AND APPLICABLE CODES AND REGULATIONS. 4. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE ALL DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT AND PIPING DIMENSIONS PRIOR TO FABRICATION. 5. WORK SHALL BE ACCURATELY LAID OUT WITH REFERENCE TO THE ARCHITECTURAL DRAWINGS AND IN COOPERATION WITH OTHER TRADES, WHICH SHALL AFFORD MAXIMUM ACCESSIBILITY FOR OPERATION, MAINTENANCE AND HEADROOM. FAILURE TO COORDINATE WORK WITH OTHER TRADES SHALL NOT BE CONSIDERED AS A BASIS FOR EXTRA COST CHANGES. 6. DIMENSIONS SHOWN ON DRAWINGS FOR DUCTWORK ARE INSIDE CLEAR. 7. ALL DUCTWORK, INCLUDING FIRE DAMPERS, SHALL BE SEALED AND TESTED FOR LEAKS PRIOR TO COVERING WORK. 8. PATCH ALL CUTTING OR DRILLING OF FINISHED WALLS, CEILINGS AND FLOORS. 9. DIFFUSER AND GRILLE LOCATIONS TO BE COORDINATED WITH ARCHITECTURAL CEILING PLAN. ANY CEILING MOUNTED DIFFUSERS OR GRILLES WHICH DO NOT MATCH CEILING TILE SIZES ARE TO BE MOUNTED IN CENTER OF TILE. 10. CONTRACTOR SHALL INSTALL ANY BALANCING DEVICE NECESSARY TO ACHIEVE PROPER ADJUSTING AND BALANCING OF MECHANICAL SYSTEMS. 11. REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ABBREVIATIONS - GENERAL MECHANICAL AAV AUTOMATIC AIR VENT AD ACCESS DOOR AFMS AIRFLOW MEASURING STATION BDD COUNTERBALANCED BACKDRAFT DAMPER BFW BOILER FEEDWATER CD CONDENSATE DRAIN CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CVD REMOTE CABLE CONTROL VOLUME DAMPER CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY DSD DUCT SMOKE DETECTOR DV HOSE BIBB DRAIN VALVE FD FIRE DAMPER FM FLOW METER FOB FLAT ON BOTTOM FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOT FLAT ON TOP GR GLYCOL RETURN GS GLYCOL SUPPLY HPS HIGH PRESSURE STEAM HRR HEAT RECOVERY RETURN HRS HEAT RECOVERY SUPPLY HWR HEATING HOT WATER RETURN HWS HEATING HOT WATER SUPPLY LPS LOW PRESSURE STEAM MAV MANUAL AIR VENT MPS MEDIUM PRESSURE STEAM PCR PUMPED CONDENSATE RETURN PRV PRESSURE REDUCING VALVE RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RV RELIEF VALVE SD SMOKE DAMPER OR SPLITTER DAMPER VD VOLUME DAMPER NOT TO SCALE 6AHOT WATER FLOW DIAGRAM NOT TO SCALE 4ANEW REHEAT LOOP HOT WATER FLOW DIAGRAM NOT TO SCALE 5BHOT WATER COIL DETAIL SCALE: 12" = 1'-0" 4BREMOTE CABLE OPERATOR DETAIL 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 08/16/16