Loading...
HomeMy WebLinkAboutB16-0266_M201_1478900260.pdfF G H J K L M N O M1 MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 STORAGE 132 ENGINEER STORAGE 133 ENGINEER 134 EMPLOYEE BREAK ROOM 135 OFFICE 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 GAME ROOM 109 OFFICE 130 OFFICE 131 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 137 WOMEN'S BATHROOM 138 MEN'S BATHROOM 139 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 W EMPLOYEE LOCKER ROOM 136 23.2 23.11 23.11 23.11 23.11 23.11 23.11 23.11 M201 6E S-1 10" DIA. 105-24 38'-0" (TOTAL PER SIDE) 24'-0" (ACTIVE PER SIDE) PROVIDE MITERED CORNERS. LOCATE REMOTE CABLE DAMPER IN RECESSED CEILING. ENGINEERED 2-1/2" HIGH SLOT RETURN IN VERTICAL FACE OF RECESSED CEILING. SEE ARCHITECTURAL PLANS FOR DETAIL. 16 SQ. FT FREE AREA. 24x14 24x14 EXISTING AIR HANDLER AHU-2 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2000 CFM SUPPLY AIR 430 CFM OUTSIDE AIR EXISTING AIR HANDLER AHU-1 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2000 CFM SUPPLY AIR 430 CFM OUTSIDE AIR EXISTING ROOFTOP UNIT RTU-2 TO PROVIDE: 120 MBH HEATING 7.5 TONS COOLING 2855 CFM SUPPLY AIR 750 CFM OUTSIDE AIR EXISTING ROOFTOP UNIT RTU-1 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2000 CFM SUPPLY AIR 390 CFM OUTSIDE AIR EXISTING AIR HANDLING UNIT AHU-3 TO PROVIDE: 50 MBH HEATING 1445 CFM SUPPLY AIR 300 CFM OUTSIDE AIR CONNECT OA DUCT TO EXISTING INTAKES ON LOW ROOF (TYP. OF 2) 6ø 32x12 32x12 8ø 10ø 8ø 18x12 12x12 10ø 8ø 6ø 8ø 8ø 8ø 26x14 12x12 8ø 8ø 8ø 8ø 20x10 8ø 8ø 12x10 8ø 8ø 12x10 8ø 26x14 8ø 8ø 8ø 8ø 8ø 8ø 24x16 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 24x14 8ø 12x12 30x16 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8x8 18x24 8ø 8ø 36x10 24x6 8x18 8ø 8ø 8ø 8ø 12x10 8ø 6ø 30x10 22x12 8ø 6ø 6ø 6ø 10ø 8ø 24x8 18x10 10x10 10x10 28x18 18x10 18x12 20x10 12x10 12x10 24x14 8ø 8ø 16x10 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 6ø 6ø 8ø 30x18 S-1 125 CFM S-1 125 CFM S-1 125 CFM S-1 125 CFM S-1 105 CFM S-1 105 CFM S-2 210 CFM S-2 210 CFM S-2 210 CFM S-2 210 CFM S-2 210 CFM S-2 210 CFM R-1 785 CFM S-2 155 CFM S-2 100 CFM S-2 110 CFM S-2 110 CFM S-2 100 CFM S-2 150 CFM S-2 150 CFM S-1 105 CFM S-1 105 CFM E-2 420 CFM S-2 130 CFM S-1 105 CFM S-1 70 CFM S-2 200 CFM S-2 200 CFM S-2 200 CFM S-2 90 CFM S-2 100 CFM S-2 100 CFM S-2 80 CFM S-2 75 CFM S-2 75 CFM S-2 200 CFM S-2 250 CFM S-2 250 CFM S-2 190 CFM S-2 190 CFM S-2 190 CFM S-2 190 CFM S-2 100 CFM S-2 100 CFM S-2 190 CFM S-2 70 CFM S-2 160 CFM S-4 90 CFM S-4 70 CFM S-2 160 CFM S-2 95 CFM S-2 95 CFM S-2 95 CFM S-2 95 CFM S-2 95 CFM S-1 105 CFM S-1 105 CFM S-1 105 CFM S-1 105 CFM E-2 90 CFM TYP. OF 4 E-2 90 CFM TYP. OF 4 AHU-5, DISCHARGE CONDENSATE TO FLOOR DRAIN IN MECAHNICAL ROOM CU-5 EF-5 EF-6 BALANCE TO 1000 CFM. COORDINATE WITH ELECTRICAL CU-1 CU-2 VAV-3 VAV-2 VAV-9 VAV-4 VAV-8 VAV-1 VAV-5 VAV-6 VAV-7 E-2 1255 CFM R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 8ø S-4 150 CFM 8x6 8x6 PROVIDE INTEGRAL FLUE FAN AT FIREPLACE. PROVIDE POSITIVE PRESSURE DUCT INTO ENCLOSURE AND PROVIDE FLUE GAP AT THE TOP N O S-3 290 CFM (TYP. OF 4) S-3 335 CFM (TYP. OF 6) 26x14 10ø 20x12 10ø 10ø 10ø 16x12 16x12 10ø 10ø 10ø 10ø 10ø 10ø 10ø 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:05:20 AM 1ST FLOOR DUCTWORK PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET M201 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" 6A1ST FLOOR EQUIPMENT AND DUCTWORK PLAN KEY NOTES 23.2 EQUIPMENT IN MECHANICAL ROOM TO REMAIN. KEEP EXISTING DUCTWORK, PIPING, AND CONTROLS IN PLACE EXCEPT WHERE OTHERWISE NOTED. 23.11 UNDERCUT DOOR FOR 100 CFM SCALE: 1/4" = 1'-0" DRAWING REF: M201 6ELOBBY FIREPLACE DUCT LAYOUT 1. MAIN DUCT RUNS SHOWN TO INDICATE GENERAL ROUTING. INSTALL TIGHT TO STRUCTURE ABOVE TO ALLOW MAXIMUM CLEARANCE BELOW. COORDINATE EXACT INSTALLATION HEIGHT WITH ALL OTHER TRADES. 2. BRANCH DUCT RUNS SHALL BE AS NOTED.EACH BRANCH DUCT SHALL BE PROVIDED WITH A MANUAL BALANCING DAMPER. 3. INSTALL THERMOSTATS AT 48" A.F.F. MEASURED TO THE TOP OF THE THERMOSTAT. 4. FIRE DAMPERS SHALL BE INSTALLED IN DUCTS PENETRATING RATED WALLS IN LOCATIONS SHOWN WITH MEANS TO ACCESS THEM, BY AN ACCESS DOOR OR 12" REMOVABLE SECTION OF DUCT. 5. PROVIDE REMOTE CABLE DAMPERS FOR DUCTWORK LOCATED IN INACCESSIBLE AREAS. GENERAL DUCTWORK NOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 08/16/16