Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B16-0266_M201_1502723399.pdf
T T T T T T F G H J K L M N O M1 MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 RETAIL 109 OFFICE 3 130 OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 W EMPLOYEE LOCKER ROOM 137 23.2 23.11 23.11 23.11 23.11 23.11 23.11 23.11 M202 5A S-1 10" DIA. 105-24 38'-0" (TOTAL PER SIDE) 24'-0" (ACTIVE PER SIDE) PROVIDE MITERED CORNERS. LOCATE REMOTE CABLE DAMPER IN RECESSED CEILING. ENGINEERED 2-1/2" HIGH SLOT RETURN IN VERTICAL FACE OF RECESSED CEILING. SEE ARCHITECTURAL PLANS FOR DETAIL. 16 SQ. FT FREE AREA. EXISTING ROOFTOP UNIT RTU-2 TO PROVIDE: 120 MBH HEATING 7.5 TONS COOLING 2850 CFM SUPPLY AIR 750 CFM OUTSIDE AIR EXISTING ROOFTOP UNIT RTU-1 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2000 CFM SUPPLY AIR 390 CFM OUTSIDE AIR EXISTING AIR HANDLING UNIT AHU-3 TO PROVIDE: 50 MBH HEATING 1480 CFM SUPPLY AIR MIN. 400 CFM OUTSIDE AIR 32x12 8ø 10ø 8ø 18x12 12x12 10ø 8ø 6ø 8ø 8ø 8ø 24x16 8ø 8ø 8ø 8ø 24x14 8ø 12x12 30x16 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 10x12 6ø 6ø 6ø 6ø 6ø 6ø 6ø 8ø 24x8 18x12 12x12 12x12 24x14 8ø 8ø 16x10 8ø 8ø 8ø 8ø 30x18 8ø S-2 140 CFM 8ø S-2 100 CFM (TYP. OF 2) 8ø S-2 95 CFM 8ø S-2 95 CFM 8ø S-2 85 CFM 8ø S-2 125 CFM 8ø S-2 125 CFM 4'-0" S-1 90 CFM 4'-0" S-1 90 CFM E-1 450 CFM 8ø S-2 130 CFM 4'-0" S-1 70 CFM 4'-0" S-1 70 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 6ø S-2 90 CFM 6ø S-2 80 CFM 6ø S-2 80 CFM 6ø S-2 60 CFM 6ø S-2 60 CFM 6ø S-2 60 CFM 8ø S-2 160 CFM S-2 250 CFM S-2 250 CFM 8ø S-2 185 CFM 8ø S-2 190 CFM 8ø S-2 190 CFM 8ø S-2 190 CFM 6ø S-2 65 CFM 6ø S-2 65 CFM 8ø S-2 170 CFM 6ø S-2 65 CFM 8ø S-2 170 CFM 10x6 S-4 190 CFM 8x6 S-4 80 CFM 6ø S-2 90 CFM 6ø S-2 95 CFM 6ø S-2 95 CFM 6ø S-2 95 CFM EF-6 CU-1 CU-2 VAV-3 VAV-2 VAV-4 VAV-8 VAV-1 VAV-7 E-1 1255 CFM R-2 R-1 R-1 R-2 R-2 R-2 R-2 R-1 R-2 R-2 R-2 R-2 R-2 R-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 6ø 8x6 S-4 150 CFM PROVIDE INTEGRAL FLUE FAN AT FIREPLACE. PROVIDE POSITIVE PRESSURE DUCT INTO ENCLOSURE AND PROVIDE FLUE GAP AT THE TOP EWH-1 SEE SHEET M202 FOR DUCTWORK ABOVE LOBBY CEILING VAV-8 VAV-3 12x10 6ø 6ø 8ø 14x12 8ø 8ø 8ø 10ø 10x12 10ø 12x6 23.13 8x6 12x8 6ø 6ø 6ø 6ø 23.15 6ø 6ø 6ø 12x10 8x8 6ø 6ø 6ø 6ø S-2 80 CFM 8ø S-2 175 CFM 6ø S-2 40 CFM 6ø VAV-4 VAV-7 VAV-5 6x6 S-4 40 CFM 10x6 8x4 6x6 23.11 23.17 M202 5D SEE SHEET M202 FOR DUCTWORK ABOVE BATHROOM CEILINGS 20x8 30x10 22x22 36x10 16x8 8x6 12x10 8ø 8ø 18x10 10x10 8ø 6x6 8ø 6ø 20x8 20x8 R-2 R-2 R-2 36x22 18x12 18x12 36x22 R-1 R-1 R-1 R-1 COVER DUCT INLET WITH 1"x1" WIRE MESH 6ø S-2 65 CFM R-2 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8ø 8x10 23.22 T AHU-1 T RTU-1 T AHU-2 T RTU-2 T AHU-3 PROVIDE MARKEL MODEL F1FUH03003 (OR EQUAL) UNIT HEATER. MOUNT UNIT AS HIGH AS POSSIBLE ON WALL. MAINTAIN MANUFACTURER REQUIRED CLEARANCE DISTANCES. DIVISION 23 TO PROVIDE ELECTRICAL DISCONNECT, ADJUSTABLE WALL BRACKET, AND BUILT IN THERMOSTAT. 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/18/2017 1:18:32 PM 1ST FLOOR DUCTWORK PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M201 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a 6A1ST FLOOR EQUIPMENT AND DUCTWORK PLAN KEY NOTES 23.2 EQUIPMENT IN MECHANICAL ROOM TO REMAIN. KEEP EXISTING DUCTWORK, PIPING, AND CONTROLS IN PLACE EXCEPT WHERE OTHERWISE NOTED. 23.11 UNDERCUT DOOR FOR 100 CFM 23.13 4" DIA. DRYER EXHAUST DUCT UP TO ROOF (TYP. OF 3). INSTALL CLOTHES DRYERS AND DRYER EXHAUST DUCT PER IMC 2012 SECTION 913 AND SECTION 504. 23.15 PROVIDE NEW 42" X 12" LOUVER. COORDINATE COLOR AND STYLE WITH ARCHITECT. MINIMUM 50% FREE AREA. 23.17 PROVIDE 12X12 IN DOOR GRILLE WITH MINIMUM 40% FREE AREA. 23.22 COORDINATE WALL HEATER LOCATION WITH ARCHITECT. 1. MAIN DUCT RUNS SHOWN TO INDICATE GENERAL ROUTING. INSTALL TIGHT TO STRUCTURE ABOVE TO ALLOW MAXIMUM CLEARANCE BELOW. COORDINATE EXACT INSTALLATION HEIGHT WITH ALL OTHER TRADES. 2. BRANCH DUCT RUNS SHALL BE AS NOTED.EACH BRANCH DUCT SHALL BE PROVIDED WITH A MANUAL BALANCING DAMPER. 3. INSTALL THERMOSTATS AT 48" A.F.F. MEASURED TO THE TOP OF THE THERMOSTAT. 4. FIRE DAMPERS SHALL BE INSTALLED IN DUCTS PENETRATING RATED WALLS IN LOCATIONS SHOWN WITH MEANS TO ACCESS THEM, BY AN ACCESS DOOR OR 12" REMOVABLE SECTION OF DUCT. 5. PROVIDE REMOTE CABLE DAMPERS FOR DUCTWORK LOCATED IN INACCESSIBLE AREAS. 6. INSTALL VAV BOXES SUCH THAT 30" CLEARANCE IS MAINTAINED FOR ACCESS TO LOW VOLTAGE CONTROL PANELS. GENERAL DUCTWORK NOTES NOT IN SCOPE OF NEW CONSTRUCTION 1 8/25/2016 FOR CONSTRUCTION SET 5 12/07/2016 RFI #55 6 1/09/2017 CCD-03 9 7/21/17 CCD-05 07/31/2017 08/14/17