HomeMy WebLinkAboutB16-0266_P001_1478900267.pdfCEILING CLEANOUT CO FLOOR CLEANOUT FCO WALL CLEANOUT WCO EXTERIOR CLEANOUT TEE OFF TOP TEE OFF BOTTOM CONCENTRIC REDUCER ECCENTRIC REDUCER ELBOW, TURNING DOWN ELBOW, TURNING UP GATE VALVE SCREWED OR SOLDERED GATE VALVE FLANGED BALL VALVE UNION MIXING VALVE P-TRAP PIPE CAP HOSE BIBB ECO DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT NEW PIPING OR EQUIPMENT (SHOWN DARK) EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING PIPING OR EQUIPMENT TO BE REMOVED MOUNT TO INSIDE OF CHASE WALL DISTRIBUTION UNIT ROUTE 1/2" UNDER FLOOR TO FLOOR DRAINS MIFAB MODEL M2-500 TRAP PRIMER MOUNTED IN ACCESSIBLE LOCATION STRAINER DOMESTIC COLD WATER BALL VALVE OFFSET DRAIN TO REUSE EXISTING SLAB PENETRATION 2" SAN SHOWER PAN NEW SHOWER VALVE 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 10:40:15 AM SCHEDULES, LEGEND & DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET P001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LEGEND - PLUMBING ABBREVIATIONS - PLUMBING WCO WALL CLEANOUT CO CLEANOUT CW DOMESTIC COLD WATER FCO FLOOR CLEANOUT G NATURAL GAS PIPING HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SAN SANITARY WASTE V VENT PIPING NOT TO SCALE 2ATRAP PRIMER DETAIL PLUMBING FIXTURE CONNECTION SCHEDULE DESIGNATION ITEM CW HW WASTE VENT REMARKS PF-1 WATER CLOSET - ADA 1/2" - 4" 2" PF-2 GUESTROOM FAUCET - ADA 3/8" 3/8" - - PF-3 GUESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-4 SHOWER PAN - - 2" 2" PF-5 SHOWER CONTROLS/SHOWERHEAD 1/2" 1/2" - - PF-6 PF-7 BATHTUB - ADA 1/2" 1/2" 2" 2" PF-8 PUBLIC RESTROOM FAUCET - ADA 3/8" 3/8" - - PF-9 PUBLIC RESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-10 URINAL - ADA 3/4" - 2" 2" WALL-HUNG URINAL - PROVIDE FIXTURE CARRIER PF-11 PUBLIC RESTROOM WATER CLOSET - ADA 1" - 4" 2" WALL-HUNG WATER CLOSET - PROVIDE FIXTURE CARRIER PF-12 PUBLIC RESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2" PF-13 BREAKROOM SINK 3/8" 3/8" 1 1/2" 1 1/2" SANITARY WASTE AND VENT PIPING: MATCH EXISTING WASTE AND VENT PIPING IN ALL RESPECTS DOMESTIC WATER PIPING: BELOW FLOOR - TYPE "K" COPPER, SOFT DRAWN (FEDERAL SPECIFICATION WW-T-799). NO FITTINGS BELOW FLOOR. ABOVE FLOOR - TYPE "L" COPPER, HARD DRAWN (FEDERAL SPECIFICATION WW-T-799). ASSEMBLED WITH WROGHT COPPER TYPE FITTINGS AND 95-5 LEAD-FREE SOLDER. DOMESTIC WATER BALL VAVLE: NIBCO NO. 585-70-66-NS, FULL PORT BRONZE BODY, STAINLESS STEEL, NIB-SEAL, INSULATED HANDLE, AND SOLDER ENDS. NATURAL GAS PIPING BLACK IRON SCH 40 GAS PIPING HANGERS AND SUPPORTS: IN GENERAL, HORIZONTAL PIPING HUNG FROM EXISTING CONSTRUCTION SHALL BE SUPPORTED BY MEANS OF PHILLIPS RED HEAD SELF DRILLING ANCHORS. GENERALLY, HORIZONTAL PIPING SHALL BE HUNG WITH CLEVIS, SPLIT RING, OR SPLIT STEEL HANGERS, GRINNEL FIGURES NOS. 260, 108, AND 212 RESPECTIVELY. HANGERS SHALL BE LARGE ENOUGH TO RECIEVE PIPE AND INSULATION. HANGER ROD SIZES SHALL BE AS CATALOG LISTED FOR A SPECIFIED HANGER. HANGER SPACING SHALL BE AS FOLLOWS: 6' O.C. FOR COPPER PIPE 1 1/4" AND SMALLER 4' O.C. FOR PVC SOIL PIPE IN ADDITION, HANGERS SHALL BE INSTALLED WITHIN 2' OF EACH CHANGE IN DIRECTION HANGERS SHALL BE LOCATED WITH RESPECT TO BEND SO AS NOT TO HAMPER EXPANSION OR CONTRACTION. OTHER FORMS AND ARRANGEMENTS OF HANGERS AND SUPPORTS SHALL BE USED TO ACCOMODATE SPECIAL OR UNUSUAL CONDITIONS OR CONDITIONS NOT COVERED HEREIN, SUBJECT TO THE APPROVAL OF THE ARCHITECTS AND ENGINEERS. PIPING INSULATION: DOMESTIC COLD WATER AND DOMESTIC HOT WATER SHALL BE INSULATED WITH 1" THICK FIBERGLASS SSL-11-2 HEAVY DENSITY SECTIONAL PIPE INSULATION JACKETED WITH REINFORCED ALL SERVICE VAPOR RETARDER JACKET. JACKET SHALL HAVE A FACTORY-APPLIED DOUBLE PRESSURE SEALING ADHESIVE THAT PROVIDES POSITIVE CLOSURE AND VAPOR SEALING OF LONGITUDINAL JOINT. JOINTS BETWEEN SECTIONS SHALL BE SEALED WITH BUTT STRIPS. LONGITUDINAL SEAMS IN ALL SERVICE JACKETS SHALL OVERLAP AND SHALL BE VAPOR SEALED. BUTT JOINTS IN STRAIGHT RUNS SHALL BE VAPOR SEALED AND THE JOINT SHALL BE SEALED WITH A JOINT SEALING STRIP. THE SHEET METAL OVERLAP OF THE HANGER INSERT SHALL ALSO BE SEALED JOINT SEALING STRIP (COLD PIPE ONLY). PIPE TESTING: TEST ALL SOIL, WASTE, AND VENT PIPING IN ACCORDANCE WITH APPLICABLE CODE. TEST ALL WATER PIPING AT 125 PSI WITH NO LOSS IN PRESSURE FOR 2 HOURS. PLUMBING SPECIFICATIONS GENERAL NOTES 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF ALL LOCAL PLUMBING, HEALTH DEPARTMENT, AND BUILDING CODES, REGULATIONS AND ORDINANCES. 2. EVERY FIXTURE, DEVICE, APPARATUS, AND PIECE OF EQUIPMENT WHICH CONVEYS, USES, OR IS ACTIVATED BY WATER SHALL BE OF SUCH DESIGN AND BE INSTALLED IN SUCH A MANNER THAT THE DOMESTIC WATER SYSTEM IS PROTECTED AGAINST CONTAMINATION. 3. ALL PLUMBING PIPING SHALL BE COORDINATED WITH OTHER DISCIPLINES, INCLUDING MECHANICAL DUCTWORK, LIGHT FIXTURES, CONDUITS, AND STRUCTURE, PRIOR TO PIPING INSTALLATION. 4. PLUMBING CONTRACTOR SHALL FLUSH OUT ALL WATER AND WASTE LINES PRIOR TO FINAL CONNECTION TO FOODSERVICE EQUIPMENT. 5. PLUMBING CONTRACTOR SHALL INSTALL ALL ACCESSORIES AND FITTINGS PROVIDED LOOSE WITH FOODSERVICE EQUIPMENT AND MAKE FINAL CONNECTIONS TO EQUIPMENT. 6. CONTRACTOR SHALL COMPLY WITH CONTRACT DOCUMENTS, INCLUDING INCORPORATION OF LATEST BRAND STANDARDS. 7. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF WORK. PLUMBING CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 8. CLEANOUTS SHALL BE INSTALLED AS INDICATED ON DRAWINGS AND AS PER APPLICABLE PLUMBING CODE. NOT TO SCALE 3ATUB TO SHOWER DEMOLITION DETAIL NOT TO SCALE 4ATUB TO SHWOER NEW WORK DETAIL FLOOR RECEPTOR SCHEDULE ITEM BODY MATERIAL FLASHING AND ANCHOR FLANGE SEDIMENT BUCKET STRAINER HEAD STRAINER MATERIAL TOP SHAPE BASIS OF DESIGN FLD-01 CAST IRON REQUIRED REQUIRED ADJUSTABLE NICKEL-BRONZE ROUND JAY R SMITH SERIES 2050 FSK-01 CAST IRON REQUIRED REQUIRED NON-ADJUSTABL E NICKEL-BRONZE SQUARE WITH 1/2 GRATE JAY R SMITH SERIES 3100 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 08/16/16