Loading...
HomeMy WebLinkAboutB16-0266_P001_1502723400.pdfCEILING CLEANOUT CO FLOOR CLEANOUT FCO WALL CLEANOUT WCO EXTERIOR CLEANOUT TEE OFF TOP TEE OFF BOTTOM CONCENTRIC REDUCER ECCENTRIC REDUCER ELBOW, TURNING DOWN ELBOW, TURNING UP GATE VALVE SCREWED OR SOLDERED GATE VALVE FLANGED BALL VALVE UNION MIXING VALVE P-TRAP PIPE CAP HOSE BIBB ECO DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT NEW PIPING OR EQUIPMENT (SHOWN DARK) EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING PIPING OR EQUIPMENT TO BE REMOVED MOUNT TO INSIDE OF CHASE WALL DISTRIBUTION UNIT ROUTE 1/2" UNDER FLOOR TO FLOOR DRAINS MIFAB MODEL M2-500 TRAP PRIMER MOUNTED IN ACCESSIBLE LOCATION STRAINER DOMESTIC COLD WATER BALL VALVE REMOVE BATHTUB, TUB SPOUT, SHOWERHEAD, AND TRIM OFFSET DRAIN TO REUSE EXISTING SLAB PENETRATION 2" SAN SHOWER PAN NEW SHOWER VALVE 5 MIL (MIN.) WRAPPED PIPE PIPE TO BE 24: BELOW GRADE ISOLATING UNION PIPE SLEEVE GRADE 1/2" TRAP PRIMER CONNECTION STRAINER DEEP SEAL P-TRAP FINISHED FLOOR 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 7/21/2017 9:46:29 AM SCHEDULES, LEGEND & DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LEGEND - PLUMBING ABBREVIATIONS - PLUMBING WCO WALL CLEANOUT CO CLEANOUT CW DOMESTIC COLD WATER FCO FLOOR CLEANOUT G NATURAL GAS PIPING HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SAN SANITARY WASTE V VENT PIPING NOT TO SCALE 2ATRAP PRIMER DETAIL PLUMBING FIXTURE CONNECTION SCHEDULE DESIGNATION ITEM CW HW WASTE VENT REMARKS PF-1 WATER CLOSET - ADA 1/2" - 4" 2" PF-2 GUESTROOM FAUCET - ADA 3/8" 3/8" - - PF-3 GUESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-4 SHOWER PAN - - 2" 2" PF-5 SHOWER CONTROLS/SHOWERHEAD 1/2" 1/2" - - PF-6 NOT USED PF-7 BATHTUB - ADA 1/2" 1/2" 2" 2" PF-8 PUBLIC RESTROOM FAUCET - ADA 3/8" 3/8" - - PF-9 PUBLIC RESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-10 URINAL - ADA 3/4" - 2" 2" WALL-HUNG URINAL - PROVIDE FIXTURE CARRIER PF-11 PUBLIC RESTROOM WATER CLOSET - ADA 1" - 4" 2" PF-12 PUBLIC RESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2" PF-13 BREAKROOM SINK 3/8" 3/8" 1 1/2" 1 1/2" PF-14 WATER COOLER 3/8" - 1 1/2" 1 1/2" WALL-HUNG WATER COOLER - PROVIDE FLOOR-MOUNTED FIXTURE CARRIER PF-15 GUESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2" DOMESTIC WATER BALL VAVLE: NIBCO NO. 585-70-66-NS, FULL PORT BRONZE BODY, STAINLESS STEEL, NIB-SEAL, INSULATED HANDLE, AND SOLDER ENDS. HANGERS AND SUPPORTS: IN GENERAL, HORIZONTAL PIPING HUNG FROM EXISTING CONSTRUCTION SHALL BE SUPPORTED BY MEANS OF PHILLIPS RED HEAD SELF DRILLING ANCHORS. GENERALLY, HORIZONTAL PIPING SHALL BE HUNG WITH CLEVIS, SPLIT RING, OR SPLIT STEEL HANGERS, GRINNEL FIGURES NOS. 260, 108, AND 212 RESPECTIVELY. HANGERS SHALL BE LARGE ENOUGH TO RECIEVE PIPE AND INSULATION. HANGER ROD SIZES SHALL BE AS CATALOG LISTED FOR A SPECIFIED HANGER. HANGER SPACING SHALL BE AS FOLLOWS: 6' O.C. FOR COPPER PIPE 1 1/4" AND SMALLER 4' O.C. FOR PVC SOIL PIPE IN ADDITION, HANGERS SHALL BE INSTALLED WITHIN 2' OF EACH CHANGE IN DIRECTION HANGERS SHALL BE LOCATED WITH RESPECT TO BEND SO AS NOT TO HAMPER EXPANSION OR CONTRACTION. OTHER FORMS AND ARRANGEMENTS OF HANGERS AND SUPPORTS SHALL BE USED TO ACCOMODATE SPECIAL OR UNUSUAL CONDITIONS OR CONDITIONS NOT COVERED HEREIN, SUBJECT TO THE APPROVAL OF THE ARCHITECTS AND ENGINEERS. PIPE TESTING: TEST ALL SOIL, WASTE, AND VENT PIPING IN ACCORDANCE WITH APPLICABLE CODE. TEST ALL WATER PIPING AT 125 PSI WITH NO LOSS IN PRESSURE FOR 2 HOURS. PLUMBING SPECIFICATIONS GENERAL NOTES 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF ALL LOCAL PLUMBING, HEALTH DEPARTMENT, AND BUILDING CODES, REGULATIONS AND ORDINANCES. 2. EVERY FIXTURE, DEVICE, APPARATUS, AND PIECE OF EQUIPMENT WHICH CONVEYS, USES, OR IS ACTIVATED BY WATER SHALL BE OF SUCH DESIGN AND BE INSTALLED IN SUCH A MANNER THAT THE DOMESTIC WATER SYSTEM IS PROTECTED AGAINST CONTAMINATION. 3. ALL PLUMBING PIPING SHALL BE COORDINATED WITH OTHER DISCIPLINES, INCLUDING MECHANICAL DUCTWORK, LIGHT FIXTURES, CONDUITS, AND STRUCTURE, PRIOR TO PIPING INSTALLATION. 4. PLUMBING CONTRACTOR SHALL FLUSH OUT ALL WATER AND WASTE LINES PRIOR TO FINAL CONNECTION TO FOODSERVICE EQUIPMENT. 5. PLUMBING CONTRACTOR SHALL INSTALL ALL ACCESSORIES AND FITTINGS PROVIDED LOOSE WITH FOODSERVICE EQUIPMENT AND MAKE FINAL CONNECTIONS TO EQUIPMENT. 6. CONTRACTOR SHALL COMPLY WITH CONTRACT DOCUMENTS, INCLUDING INCORPORATION OF LATEST BRAND STANDARDS. 7. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF WORK. PLUMBING CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 8. CLEANOUTS SHALL BE INSTALLED AS INDICATED ON DRAWINGS AND AS PER APPLICABLE PLUMBING CODE. NOT TO SCALE 3ATUB TO SHOWER DEMOLITION DETAIL NOT TO SCALE 4ATUB TO SHOWER NEW WORK DETAIL FLOOR RECEPTOR SCHEDULE ITEM BODY MATERIAL FLASHING AND ANCHOR FLANGE SEDIMENT BUCKET STRAINER HEAD STRAINER MATERIAL TOP SHAPE BASIS OF DESIGN FLD-01 CAST IRON REQUIRED REQUIRED ADJUSTABLE NICKEL-BRONZE ROUND JAY R SMITH SERIES 2050 FSK-01 CAST IRON REQUIRED REQUIRED NON-ADJUSTABLE NICKEL-BRONZE SQUARE WITH 1/2 GRATE JAY R SMITH SERIES 3100 PLUMBING FIXTURE SPECIFICATIONS ITEM SPECIFICATION PF-1 KOHLER "CIMARRON" ELONGATED BOWL TOILET MODEL K-3589. TRIP LEVER TO BE ON OPEN SIDE OF ROOM. PROVIDE KOHLER MODEL K-4731-C-0 COMMERCIAL HEAVY-DUTY WHITE ELONGATED OPEN FRONT SEAT AND KOHLER NO. K-7637 ANGLE SUPPLY WITH STOP. PF-2 KOHLER "COMPOSED" WIDESPREAD BATHROOM SINK FAUCET MODEL K-73060-4. PF-3 KOHLER "TRESHAM" DROP-IN BATHROOM SINK MODEL K-2991-8. PROVIDE P-TRAP AND SUPPLY INSULATION EQUAL TO TRUEBRO "LAV-GUARD 2". PF-4 SHOWER BASE SHALL BE BELSTONE 60"x30" SOLID SURFACE LOW PROFILE SHOWER PAN WITH 3-1/2"x 3" SHOWER DAM. SHOWER PAN COLOR: WHITE PF-5 SHOWER TRIM AND VALVE TO BE "CORALAIS" SHOWER VALVE TRIM WITH LEVER HANDLE KOHLER MODEL K-T15621-4-CP POLISHED CHROME FINISH WITH KOHLER MODEL K-304-KS-NA RITE-TEMP VALVE WITH STOPS. FIXED SHOWER HEAD TO BE KOHLER "FORTE" 2.5 GPM MULTI-FUNCTION SHOWER HEAD MODEL K-10284-CP. PF-7 BATHTUB SHALL BE KOHLER "VILLAGER BATH" 60"X30"X14" CAST-IRON WITH SAFEGUARD FINISH MODEL NO. K-715 (LEFT DRAIN) OR K-716 (RIGHT DRAIN) DEPENDING ON ROOM TYPE. PROVIDE GERBER MODEL NO. 41-802 17 GAUGE CHROME POP-UP BATH DRAIN. BATH SPOUT SHALL BE "FORTE" MODEL NO. K-10280-4A. VALVE TRIM TO BE KOHLER "FORTE" K-T10277-4 WITH KOHLER NO. K-304-KS RITE-TEMP PRESSURE BALANCING VALVE. SHOWERHEAD TO BE KOHLER "FORTE" MULTI-FUNCTION SHOWERHEAD NO. K-10284-CP WITH NO. K-7397-CP SHOWER ARM AND FLANGE. HANDHELD SHOWER TO BE KOHLER "FORTE" MULTI-FUNCTION HANDSHOWER MODEL NO. K-10286-CP WITH KOHLER NO. K-9514 60" METAL SHOWER HOSE AND NO. K-355-CP SUPPLY ELBOW. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR WITH MODEL K-349-CP SLIDEBAR TRIM. KOHLER MODEL K-7142-CP KOHLER CLEARFLO RETROFIT TOE TAP CONVERSION KIT. PF-8 KOHLER "SCULPTED" TOUCHLESS FAUCET MODEL K-13463-CP PF-9 KOHLER "KATHRYN" K-2330-G-0 UNDERMOUNT SINK PF-10 KOHLER "BARDON" MODEL K-4991-ET-0 URINAL - KOHLER WASHDOWN MODEL K-13519-CP FLUSH VALVE, 0.5 GPF PF-11 KOHLER "HIGHCREST" MODEL K-4302 FLOOR-MOUNTED WATER CLOSET - MODEL K-13517-CP MANUAL FUSH VALVE, 1.28 GPF - MODEL K-4731-C TOILET SEAT PF-12 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING VALVE PF-13 ELKAY MODEL LRADQ332255 STAINLESS STEEL DOUBLE BOWL TOP MOUNTED SINK - ELKAY MODEL LKD2442C FAUCET PF-14 ELKAY MODEL DZTL8C PF-15 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING VALVE. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR WITH MODEL K-349-CP SLIDEBAR TRIM. NOT TO SCALE 1B GAS PIPING EXTERIOR WALL PENETRATION DETAIL NOT TO SCALE3BFLOOR DRAIN FLD-01 DETAIL NOTES: -SEE "FLOOR DRAIN FLD-01 DETAIL" ON THIS SHEET FOR FLD-01 -SEE "FLOOR RECEPTOR DETAIL" ON DRAWING P402 FOR FSK-01 PLUMBING PIPE AND INSULATION SCHEDULE SERVICE PIPE MATERIAL PIPE INSULATION WASTE AND VENT PIPING (ABOVE FLOOR) HUBLESS CAST IRON (NO HUB) PIPE AND FITTINGS, COATED INSIDE AND OUT, (CISPI-301), JOINTS SHALL BE MADE WITH STAINLESS STEEL SHIELD AND CLAMP WITH NEOPRENE SEALING SLEEVE WASTE AND VENT PIPING (BELOW FLOOR) POLYVINYL CHLORIDE - PVC, TYPE DWV, ASTM D 2665, WITH MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE FROM MOISTURE. A PURPLE PRIMER THAT CONFORMS WITH ASTM F 656 SHALL BE APPLIED. SOLVENT CEMENT NOT PURPLE IN COLOR AND CONFORMING TO ASTM D 2564 SHALL BE APPLIED TO ALL JOINT SURFACES. THE JOINT SHALL BE MADE WHILE THE CEMENT IS WET AND SHALL BE IN ACCORDANCE WITH ASTM D 2588. DOMESTIC HOT AND COLD WATER PIPING TYPE "L" COPPER, HARD DRAWN, ASSEMBLED WITH WROUGH COPPER TYPE FIITINGS AND 95-5 LEAD-FREE SOLDER. INSULATE ALL DOMESTIC WATER PIPING WITH 1" THICK OWENS/CORNING FIBERGLASS 25 ASJ/SLL-II 2-PIECE HEAVY-DENSITY SECTIONAL PIPE INSULATION JACKETED WITH AN EMBOSSED VAPOR BARRIER LAMINATE, JACKET SHALL HAVE A PRESSURE SEALING LAP ADHESIVE TO ELIMINATE THE USE OF STAPLES, ADHESIVE, OR BANDS. NATURAL GAS PIPING BLACK STEEL SCH 40, STANDARD WEIGHT, ASTM A53 CONTINUOUS WELD WITH 150 POUND MALLEABLE FITTINGS 1 8/25/2016 FOR CONSTRUCTION SET 3 10/07/2016 ASI #1 9 7/21/17 CCD-05 07/31/2017 08/14/17