HomeMy WebLinkAboutB16-0266_P001_1502723400.pdfCEILING CLEANOUT
CO
FLOOR CLEANOUT
FCO
WALL CLEANOUT
WCO
EXTERIOR CLEANOUT
TEE OFF TOP
TEE OFF BOTTOM
CONCENTRIC REDUCER
ECCENTRIC REDUCER
ELBOW, TURNING DOWN
ELBOW, TURNING UP
GATE VALVE SCREWED OR SOLDERED
GATE VALVE FLANGED
BALL VALVE
UNION
MIXING VALVE
P-TRAP
PIPE CAP
HOSE BIBB
ECO
DIRECTION OF FLOW
PITCH DOWN IN DIRECTION OF ARROW
POINT OF CONNECTION, NEW TO EXISTING
REMOVE TO THIS POINT
NEW PIPING OR EQUIPMENT (SHOWN DARK)
EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT)
EXISTING PIPING OR EQUIPMENT TO BE REMOVED
MOUNT TO INSIDE
OF CHASE WALL
DISTRIBUTION UNIT
ROUTE 1/2" UNDER FLOOR
TO FLOOR DRAINS
MIFAB MODEL M2-500 TRAP
PRIMER MOUNTED IN
ACCESSIBLE LOCATION
STRAINER
DOMESTIC COLD WATER
BALL VALVE
REMOVE BATHTUB, TUB SPOUT,
SHOWERHEAD, AND TRIM
OFFSET DRAIN TO REUSE
EXISTING SLAB PENETRATION
2" SAN
SHOWER PAN
NEW SHOWER
VALVE
5 MIL (MIN.) WRAPPED PIPE
PIPE TO BE 24: BELOW GRADE
ISOLATING UNION
PIPE SLEEVE
GRADE
1/2" TRAP PRIMER
CONNECTION
STRAINER
DEEP SEAL P-TRAP
FINISHED FLOOR
1
A 2 3 4 5 6 A B C D E
1
3 4 5 6
2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING
NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
7/21/2017
9:46:29 AM
SCHEDULES, LEGEND
& DETAILS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/16 -
CONSTRUCTION
DOCUMENTS
P001
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
LEGEND - PLUMBING
ABBREVIATIONS - PLUMBING
WCO WALL CLEANOUT
CO CLEANOUT
CW DOMESTIC COLD WATER
FCO FLOOR CLEANOUT
G NATURAL GAS PIPING
HW DOMESTIC HOT WATER
HWR DOMESTIC HOT WATER RETURN
SAN SANITARY WASTE
V VENT PIPING
NOT TO SCALE
2ATRAP PRIMER DETAIL
PLUMBING FIXTURE CONNECTION SCHEDULE
DESIGNATION ITEM CW HW WASTE VENT REMARKS
PF-1 WATER CLOSET - ADA 1/2" - 4" 2"
PF-2 GUESTROOM FAUCET - ADA 3/8" 3/8" - -
PF-3 GUESTROOM SINK - ADA - - 1 1/2" 1 1/2"
PF-4 SHOWER PAN - - 2" 2"
PF-5 SHOWER CONTROLS/SHOWERHEAD 1/2" 1/2" - -
PF-6 NOT USED
PF-7 BATHTUB - ADA 1/2" 1/2" 2" 2"
PF-8 PUBLIC RESTROOM FAUCET - ADA 3/8" 3/8" - -
PF-9 PUBLIC RESTROOM SINK - ADA - - 1 1/2" 1 1/2"
PF-10 URINAL - ADA 3/4" - 2" 2" WALL-HUNG URINAL - PROVIDE FIXTURE CARRIER
PF-11 PUBLIC RESTROOM WATER CLOSET - ADA 1" - 4" 2"
PF-12 PUBLIC RESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2"
PF-13 BREAKROOM SINK 3/8" 3/8" 1 1/2" 1 1/2"
PF-14 WATER COOLER 3/8" - 1 1/2" 1 1/2" WALL-HUNG WATER COOLER - PROVIDE FLOOR-MOUNTED
FIXTURE CARRIER
PF-15 GUESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2"
DOMESTIC WATER BALL VAVLE:
NIBCO NO. 585-70-66-NS, FULL PORT BRONZE BODY, STAINLESS STEEL, NIB-SEAL, INSULATED HANDLE, AND SOLDER ENDS.
HANGERS AND SUPPORTS:
IN GENERAL, HORIZONTAL PIPING HUNG FROM EXISTING CONSTRUCTION SHALL BE SUPPORTED BY MEANS OF PHILLIPS RED HEAD SELF DRILLING ANCHORS.
GENERALLY, HORIZONTAL PIPING SHALL BE HUNG WITH CLEVIS, SPLIT RING, OR SPLIT STEEL HANGERS, GRINNEL FIGURES NOS. 260, 108, AND 212 RESPECTIVELY. HANGERS SHALL
BE LARGE ENOUGH TO RECIEVE PIPE AND INSULATION. HANGER ROD SIZES SHALL BE AS CATALOG LISTED FOR A SPECIFIED HANGER.
HANGER SPACING SHALL BE AS FOLLOWS:
6' O.C. FOR COPPER PIPE 1 1/4" AND SMALLER
4' O.C. FOR PVC SOIL PIPE
IN ADDITION, HANGERS SHALL BE INSTALLED WITHIN 2' OF EACH CHANGE IN DIRECTION HANGERS SHALL BE LOCATED WITH RESPECT TO BEND SO AS NOT TO HAMPER EXPANSION OR
CONTRACTION.
OTHER FORMS AND ARRANGEMENTS OF HANGERS AND SUPPORTS SHALL BE USED TO ACCOMODATE SPECIAL OR UNUSUAL CONDITIONS OR CONDITIONS NOT COVERED HEREIN,
SUBJECT TO THE APPROVAL OF THE ARCHITECTS AND ENGINEERS.
PIPE TESTING:
TEST ALL SOIL, WASTE, AND VENT PIPING IN ACCORDANCE WITH APPLICABLE CODE.
TEST ALL WATER PIPING AT 125 PSI WITH NO LOSS IN PRESSURE FOR 2 HOURS.
PLUMBING SPECIFICATIONS
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF
ALL LOCAL PLUMBING, HEALTH DEPARTMENT, AND BUILDING CODES, REGULATIONS
AND ORDINANCES.
2. EVERY FIXTURE, DEVICE, APPARATUS, AND PIECE OF EQUIPMENT WHICH CONVEYS,
USES, OR IS ACTIVATED BY WATER SHALL BE OF SUCH DESIGN AND BE INSTALLED
IN SUCH A MANNER THAT THE DOMESTIC WATER SYSTEM IS PROTECTED AGAINST
CONTAMINATION.
3. ALL PLUMBING PIPING SHALL BE COORDINATED WITH OTHER DISCIPLINES,
INCLUDING MECHANICAL DUCTWORK, LIGHT FIXTURES, CONDUITS, AND STRUCTURE,
PRIOR TO PIPING INSTALLATION.
4. PLUMBING CONTRACTOR SHALL FLUSH OUT ALL WATER AND WASTE LINES PRIOR
TO FINAL CONNECTION TO FOODSERVICE EQUIPMENT.
5. PLUMBING CONTRACTOR SHALL INSTALL ALL ACCESSORIES AND FITTINGS
PROVIDED LOOSE WITH FOODSERVICE EQUIPMENT AND MAKE FINAL CONNECTIONS
TO EQUIPMENT.
6. CONTRACTOR SHALL COMPLY WITH CONTRACT DOCUMENTS, INCLUDING
INCORPORATION OF LATEST BRAND STANDARDS.
7. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF
WORK. PLUMBING CONTRACTOR SHALL VERIFY EXISTING CONDITIONS.
8. CLEANOUTS SHALL BE INSTALLED AS INDICATED ON DRAWINGS AND AS PER
APPLICABLE PLUMBING CODE.
NOT TO SCALE
3ATUB TO SHOWER DEMOLITION DETAIL
NOT TO SCALE
4ATUB TO SHOWER NEW WORK DETAIL
FLOOR RECEPTOR SCHEDULE
ITEM BODY MATERIAL
FLASHING AND
ANCHOR FLANGE
SEDIMENT
BUCKET STRAINER HEAD
STRAINER
MATERIAL TOP SHAPE BASIS OF DESIGN
FLD-01 CAST IRON REQUIRED REQUIRED ADJUSTABLE NICKEL-BRONZE ROUND JAY R SMITH SERIES 2050
FSK-01 CAST IRON REQUIRED REQUIRED NON-ADJUSTABLE NICKEL-BRONZE SQUARE WITH
1/2 GRATE
JAY R SMITH SERIES 3100
PLUMBING FIXTURE SPECIFICATIONS
ITEM SPECIFICATION
PF-1 KOHLER "CIMARRON" ELONGATED BOWL TOILET MODEL K-3589. TRIP LEVER TO BE ON OPEN SIDE OF ROOM. PROVIDE KOHLER MODEL K-4731-C-0 COMMERCIAL
HEAVY-DUTY WHITE ELONGATED OPEN FRONT SEAT AND KOHLER NO. K-7637 ANGLE SUPPLY WITH STOP.
PF-2 KOHLER "COMPOSED" WIDESPREAD BATHROOM SINK FAUCET MODEL K-73060-4.
PF-3 KOHLER "TRESHAM" DROP-IN BATHROOM SINK MODEL K-2991-8. PROVIDE P-TRAP AND SUPPLY INSULATION EQUAL TO TRUEBRO "LAV-GUARD 2".
PF-4 SHOWER BASE SHALL BE BELSTONE 60"x30" SOLID SURFACE LOW PROFILE SHOWER PAN WITH 3-1/2"x 3" SHOWER DAM. SHOWER PAN COLOR: WHITE
PF-5 SHOWER TRIM AND VALVE TO BE "CORALAIS" SHOWER VALVE TRIM WITH LEVER HANDLE KOHLER MODEL K-T15621-4-CP POLISHED CHROME FINISH WITH KOHLER
MODEL K-304-KS-NA RITE-TEMP VALVE WITH STOPS. FIXED SHOWER HEAD TO BE KOHLER "FORTE" 2.5 GPM MULTI-FUNCTION SHOWER HEAD MODEL K-10284-CP.
PF-7 BATHTUB SHALL BE KOHLER "VILLAGER BATH" 60"X30"X14" CAST-IRON WITH SAFEGUARD FINISH MODEL NO. K-715 (LEFT DRAIN) OR K-716 (RIGHT DRAIN) DEPENDING
ON ROOM TYPE. PROVIDE GERBER MODEL NO. 41-802 17 GAUGE CHROME POP-UP BATH DRAIN. BATH SPOUT SHALL BE "FORTE" MODEL NO. K-10280-4A. VALVE TRIM
TO BE KOHLER "FORTE" K-T10277-4 WITH KOHLER NO. K-304-KS RITE-TEMP PRESSURE BALANCING VALVE. SHOWERHEAD TO BE KOHLER "FORTE" MULTI-FUNCTION
SHOWERHEAD NO. K-10284-CP WITH NO. K-7397-CP SHOWER ARM AND FLANGE. HANDHELD SHOWER TO BE KOHLER "FORTE" MULTI-FUNCTION HANDSHOWER MODEL
NO. K-10286-CP WITH KOHLER NO. K-9514 60" METAL SHOWER HOSE AND NO. K-355-CP SUPPLY ELBOW. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL
K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR WITH MODEL K-349-CP SLIDEBAR TRIM. KOHLER MODEL K-7142-CP
KOHLER CLEARFLO RETROFIT TOE TAP CONVERSION KIT.
PF-8 KOHLER "SCULPTED" TOUCHLESS FAUCET MODEL K-13463-CP
PF-9 KOHLER "KATHRYN" K-2330-G-0 UNDERMOUNT SINK
PF-10 KOHLER "BARDON" MODEL K-4991-ET-0 URINAL - KOHLER WASHDOWN MODEL K-13519-CP FLUSH VALVE, 0.5 GPF
PF-11 KOHLER "HIGHCREST" MODEL K-4302 FLOOR-MOUNTED WATER CLOSET - MODEL K-13517-CP MANUAL FUSH VALVE, 1.28 GPF - MODEL K-4731-C TOILET SEAT
PF-12 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL
K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING
VALVE
PF-13 ELKAY MODEL LRADQ332255 STAINLESS STEEL DOUBLE BOWL TOP MOUNTED SINK - ELKAY MODEL LKD2442C FAUCET
PF-14 ELKAY MODEL DZTL8C
PF-15 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL
K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING
VALVE. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR
WITH MODEL K-349-CP SLIDEBAR TRIM.
NOT TO SCALE
1B
GAS PIPING EXTERIOR WALL
PENETRATION DETAIL
NOT
TO SCALE3BFLOOR DRAIN FLD-01 DETAIL
NOTES:
-SEE "FLOOR DRAIN FLD-01 DETAIL" ON THIS SHEET FOR FLD-01
-SEE "FLOOR RECEPTOR DETAIL" ON DRAWING P402 FOR FSK-01
PLUMBING PIPE AND INSULATION SCHEDULE
SERVICE PIPE MATERIAL PIPE INSULATION
WASTE AND VENT PIPING (ABOVE FLOOR) HUBLESS CAST IRON (NO HUB) PIPE AND FITTINGS, COATED INSIDE
AND OUT, (CISPI-301), JOINTS SHALL BE MADE WITH STAINLESS
STEEL SHIELD AND CLAMP WITH NEOPRENE SEALING SLEEVE
WASTE AND VENT PIPING (BELOW FLOOR) POLYVINYL CHLORIDE - PVC, TYPE DWV, ASTM D 2665, WITH
MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE
FROM MOISTURE. A PURPLE PRIMER THAT CONFORMS WITH ASTM
F 656 SHALL BE APPLIED. SOLVENT CEMENT NOT PURPLE IN COLOR
AND CONFORMING TO ASTM D 2564 SHALL BE APPLIED TO ALL
JOINT SURFACES. THE JOINT SHALL BE MADE WHILE THE CEMENT
IS WET AND SHALL BE IN ACCORDANCE WITH ASTM D 2588.
DOMESTIC HOT AND COLD WATER PIPING TYPE "L" COPPER, HARD DRAWN, ASSEMBLED WITH WROUGH
COPPER TYPE FIITINGS AND 95-5 LEAD-FREE SOLDER.
INSULATE ALL DOMESTIC WATER PIPING WITH 1" THICK
OWENS/CORNING FIBERGLASS 25 ASJ/SLL-II 2-PIECE
HEAVY-DENSITY SECTIONAL PIPE INSULATION JACKETED WITH
AN EMBOSSED VAPOR BARRIER LAMINATE, JACKET SHALL
HAVE A PRESSURE SEALING LAP ADHESIVE TO ELIMINATE THE
USE OF STAPLES, ADHESIVE, OR BANDS.
NATURAL GAS PIPING BLACK STEEL SCH 40, STANDARD WEIGHT, ASTM A53 CONTINUOUS
WELD WITH 150 POUND MALLEABLE FITTINGS
1 8/25/2016 FOR CONSTRUCTION SET
3 10/07/2016 ASI #1
9 7/21/17 CCD-05
07/31/2017
08/14/17