HomeMy WebLinkAboutB16-0266_P401_1478900288.pdfDRD
R
DRD
R
4" SAN
2" SAN
4" SAN
2" SAN
4" SAN
4" SAN
2" V
2" V
2" V
2" V
2" SAN
2" SAN
2" SAN
2" SAN
2" V
2" V
2" V
2" V
2" V
2" V
2" SAN
2" SAN
2" SAN
2" SAN
2" V
2" V
2" V
2" V
PF-11
PF-8,9
FLD-01
FLD-01
3" SAN
3" SAN
2" V
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-10
PF-10
PF-10
WCO
22.23
WCO
1/8" PER FT
1/8" PER FT
GUEST
LAUNDRY
147
1/2" CW
1/2" HW
2" SAN
2" V
22.22
22.23
4" SAN
3" SAN
2" V
4" SAN
3" SAN
3" SAN
2" V
3" SAN
3" SAN
3" SAN
4" SAN
22.21
W EMPLOYEE
LOCKER
ROOM
136
M EMPLOYEE
LOCKER
ROOM
137
WOMEN'S
BATHROOM
138
MEN'S
BATHROOM
139
PF-10
PF-11
PF-11 PF-11
PF-12 PF-12
PF-12
PF-12
PF-11
PF-11 PF-11
PF-10
PF-8,9 PF-8,9
PF-8,9 PF-8,9
PF-8,9 PF-8,9
PF-8,9 PF-8,9
WCO
FLD-01 FLD-01
2" SAN
22.23
22.23
1/8" PER FT
1/4" PER FT
2 1/2" CW
1" HW
3/4" CW 3/4" CW
3/4" HW
3/4" HW
2 1/2" CW
2 1/2" CW
2" CW
1 1/2" CW
1" CW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
3/4" CW
3/4" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
3/4" CW
3/4" HW
WHA
22.20
PF-11
PF-8,9
PF-8,9
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-11
PF-10
PF-10
PF-10
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-8,9
PF-8,9
1" HW 2" CW
3/4" HW
1" HW
1" HW
3/4" HW
PF-10
PF-11
PF-11 PF-11
2" CW
2" CW
2" CW
1 1/2" CW
1 1/2" CW
1" CW
3/4" CW
PF-12
1/2" CW
22.20 22.20
WHA
PF-12
PF-12 PF-12
PF-11
PF-11 PF-11
PF-10
PF-8,9 PF-8,9
PF-8,9 PF-8,9
PF-8,9 PF-8,9
PF-8,9 PF-8,9
22.2322.23
22.2322.23
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
10:41:00 AM
ENLARGED PUBLIC
SPACE PLANS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
P401
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0" DRAWING REF: P111
1AENLARGED PUBLIC RESTROOM PLAN - WASTE AND VENT
SCALE: 1/4" = 1'-0" DRAWING REF: P111
5AENLARGED PUBLIC LAUNDRY PLAN
SCALE: 1/4" = 1'-0" DRAWING REF: P111
3CENLARGED EMPLOYEE RESTROOM AND LOCKER ROOM PLAN - WASTE AND VENT
SCALE: 1/4" = 1'-0" DRAWING REF: P111 4AENLARGED PUBLIC RESTROOM PLAN - DOMESTIC
SCALE: 1/4" = 1'-0" DRAWING REF: P111 5CENLARGED EMPLOYEE RESTROOM AND LOCKER ROOM PLAN - DOMESTIC WATER
PLAN KEYNOTES
22.20 1/2" CW DOWN TO TRAP PRIMER. SEE TRAP PRIMER DETAIL ON DRAWING NO.
P001.
22.21 2" VENT UP. TIE INTO EXISTING VENT STACK WITHIN PLUMBING CHASE AT 2ND
FLOOR.
22.22 INSTALL WASHER BOX WITH WATER HAMMER ARRESTORS EQUAL TO IPS CORP.
"WATER-TITE" MODEL NO. W9700 HA.
22.23 SEE DRAWING P111 FOR CONTINUATION
GENERAL NOTES
1. ALL FIXTURES BEING REPLACED SHALL HAVE NEW WATER SUPPLY STOPS,
P-TRAPS, AND WALL ESCUTCHEONS.
2. ADA LAVATORIES SHALL HAVE SUPPLY STOPS AND P-TRAP INSULATION INSTALLED
EQUAL TO TRUEBRO "LAV-GUARD-2".
07/11/2016
P.O. BOX 400, RICHMOND,
VA 23218-0400
®
08/16/16