Loading...
HomeMy WebLinkAboutB16-0266_P401_1478900288.pdfDRD R DRD R 4" SAN 2" SAN 4" SAN 2" SAN 4" SAN 4" SAN 2" V 2" V 2" V 2" V 2" SAN 2" SAN 2" SAN 2" SAN 2" V 2" V 2" V 2" V 2" V 2" V 2" SAN 2" SAN 2" SAN 2" SAN 2" V 2" V 2" V 2" V PF-11 PF-8,9 FLD-01 FLD-01 3" SAN 3" SAN 2" V PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-10 PF-10 PF-10 WCO 22.23 WCO 1/8" PER FT 1/8" PER FT GUEST LAUNDRY 147 1/2" CW 1/2" HW 2" SAN 2" V 22.22 22.23 4" SAN 3" SAN 2" V 4" SAN 3" SAN 3" SAN 2" V 3" SAN 3" SAN 3" SAN 4" SAN 22.21 W EMPLOYEE LOCKER ROOM 136 M EMPLOYEE LOCKER ROOM 137 WOMEN'S BATHROOM 138 MEN'S BATHROOM 139 PF-10 PF-11 PF-11 PF-11 PF-12 PF-12 PF-12 PF-12 PF-11 PF-11 PF-11 PF-10 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 WCO FLD-01 FLD-01 2" SAN 22.23 22.23 1/8" PER FT 1/4" PER FT 2 1/2" CW 1" HW 3/4" CW 3/4" CW 3/4" HW 3/4" HW 2 1/2" CW 2 1/2" CW 2" CW 1 1/2" CW 1" CW 1/2" CW 1/2" HW 1/2" CW 1/2" HW 3/4" CW 3/4" HW 1/2" CW 1/2" HW 1/2" CW 1/2" HW 3/4" CW 3/4" HW WHA 22.20 PF-11 PF-8,9 PF-8,9 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-11 PF-10 PF-10 PF-10 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 1" HW 2" CW 3/4" HW 1" HW 1" HW 3/4" HW PF-10 PF-11 PF-11 PF-11 2" CW 2" CW 2" CW 1 1/2" CW 1 1/2" CW 1" CW 3/4" CW PF-12 1/2" CW 22.20 22.20 WHA PF-12 PF-12 PF-12 PF-11 PF-11 PF-11 PF-10 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 PF-8,9 22.2322.23 22.2322.23 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 10:41:00 AM ENLARGED PUBLIC SPACE PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET P401 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: P111 1AENLARGED PUBLIC RESTROOM PLAN - WASTE AND VENT SCALE: 1/4" = 1'-0" DRAWING REF: P111 5AENLARGED PUBLIC LAUNDRY PLAN SCALE: 1/4" = 1'-0" DRAWING REF: P111 3CENLARGED EMPLOYEE RESTROOM AND LOCKER ROOM PLAN - WASTE AND VENT SCALE: 1/4" = 1'-0" DRAWING REF: P111 4AENLARGED PUBLIC RESTROOM PLAN - DOMESTIC SCALE: 1/4" = 1'-0" DRAWING REF: P111 5CENLARGED EMPLOYEE RESTROOM AND LOCKER ROOM PLAN - DOMESTIC WATER PLAN KEYNOTES 22.20 1/2" CW DOWN TO TRAP PRIMER. SEE TRAP PRIMER DETAIL ON DRAWING NO. P001. 22.21 2" VENT UP. TIE INTO EXISTING VENT STACK WITHIN PLUMBING CHASE AT 2ND FLOOR. 22.22 INSTALL WASHER BOX WITH WATER HAMMER ARRESTORS EQUAL TO IPS CORP. "WATER-TITE" MODEL NO. W9700 HA. 22.23 SEE DRAWING P111 FOR CONTINUATION GENERAL NOTES 1. ALL FIXTURES BEING REPLACED SHALL HAVE NEW WATER SUPPLY STOPS, P-TRAPS, AND WALL ESCUTCHEONS. 2. ADA LAVATORIES SHALL HAVE SUPPLY STOPS AND P-TRAP INSULATION INSTALLED EQUAL TO TRUEBRO "LAV-GUARD-2". 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 08/16/16