HomeMy WebLinkAboutB16-0266_P410_1478900293.pdf22.41
22.40
22.42
22.42
22.40
22.41
22.43
22.4422.4422.44
K
206
KA
204
K
203
KA
202
2" SAN
4" SAN
2" SAN
2" SAN
4" SAN
2" SAN 4" SAN
22.51
22.52
22.50
22.50
22.51
22.53
22.51
22.50
22.52 22.51
22.50
22.53
PF-4
PF-1
PF-2,3
PF-7
PF-1
PF-1
PF-2,3
PF-7
PF-4
PF-1
PF-2,3
1 1/2" SAN
PF-2,3
4" SAN
22.42
22.41
22.40
QA
306
2" SAN
4" SAN
22.51
22.50
22.52
PF-1
PF-2,3
PF-7
22.40
22.41
22.42
QA
406
2" SAN
22.52
22.51
22.50
4" SAN
1 1/2" SAN
PF-1
PF-2,3
PF-7
22.4022.40
22.42
22.41
Q
410
22.50
22.51
22.52
4" SAN
2" SAN
2" SAN
PF-7
PF-1
PF-2,3
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
TOWN OF VAIL USE
7/11/2016
10:41:10 AM
ENLARGED
GUESTROOM
DETAILS
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
07/08/16 - PERMIT SET
P410
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0"
3AENLARGED 2nd FLOOR PLAN - DEMOLITION
SCALE: 1/4" =
1'-0"5AENLARGED 2nd FLOOR PLAN - NEW WORK
SCALE: 1/4" = 1'-0"1CQA (RM 306) - DEMOLITION
SCALE: 1/4" = 1'-0"
2CQA (RM 306) - NEW WORK
SCALE: 1/4" = 1'-0" DRAWING REF: P1143CQA (RM 406) - DEMOLITION
SCALE: 1/4" = 1'-0" DRAWING REF: P1144CQA (RM 406) - NEW WORK
SCALE: 1/4" = 1'-0" DRAWING REF: P1145CQ (RM 410) - DEMOLITION
SCALE: 1/4" = 1'-0" DRAWING REF: P1146CQ (RM 410) - NEW WORK
PLAN KEYNOTES
22.40 REMOVE LAVATORY, FAUCET, AND PIPING
22.41 REMOVE WATER CLOSET AND PIPING
22.42 REMOVE BATHTUB, SHOWER/TUB CONTROLS, BATH SPOUT, SHOWERHEAD, AND
PIPING.
22.43 REMOVE FLOOR SINK AND PATCH HOLE FOR NEW FINISH.
22.44 REMOVE WASHER BOXES AND PIPING TO MAINS.
22.50 INSTALL NEW LAVATORY AND FAUCET. REWORK EXISTING PIPING TO CONNECT
TO MAINS.
22.51 INSTALL NEW WATER CLOSET. REWORK EXISTING PIPING TO CONNECT TO WASTE
STACK AND CW.
22.52 INSTALL NEW BATHTUB, CONTROLS, SPOUT, AND SHOWERHEAD. REWORK PIPING
TO CONNECT TO EXISTING.
22.53 INSTALL NEW SHOWER PAN, CONTROLS, AND SHOWERHEAD. REWORK PIPING TO
CONNECT TO EXISTING.
GENERAL NOTES
1. ALL FIXTURES BEING REPLACED SHALL HAVE NEW WATER SUPPLY STOPS,
P-TRAPS, AND WALL ESCUTCHEONS.
2. ADA LAVATORIES SHALL HAVE SUPPLY STOPS AND P-TRAP INSULATION INSTALLED
EQUAL TO TRUEBRO "LAV-GUARD-2".
3. VERIFY LOCATIONS OF EXISTING PIPING WITHIN PLUMBING CHASES AND ABOVE
CEILINGS IN FIELD.
07/11/2016
P.O. BOX 400, RICHMOND,
VA 23218-0400
®
08/16/16