B16-0266_REV6 approved plans_1515713563.pdf
E C WINDOW TYPE (ALPHABETIC) REVISION (NUMERIC) COLUMN LINE WORK OR DATUM POINT C 9'-0" A.F.F. CEILING TYPE / FINISH CEILING HEIGHT F FLOOR FINISH B BASE FINISH W WALL FINISH DOOR NUMBER 123A ROOMNAME A123 ROOM NUMBER BUILDING PORTION (WHEN USED) A4a PARTITION TYPE 1A A101 SIM DRAWING WHERE SHOWN SECTION CALL-OUT A101 2A 3B 3A 2B ELEVATION CALL-OUT DRAWING WHERE SHOWN 1A A101 DETAIL CALL-OUT DRAWING WHERE SHOWN 1.01 KEYNOTE T TRIM FINISH FURNITURE TYPE204 306 INTERIOR FINISH INDEX E.8 OR EXISTING PARTITION EXISTING PARTITION TO BE DEMOLISHED NOTE: REFER TO LIFE SAFETY DRAWING(S) FOR RATED PARTITION INDICATIONS NEW PARTITION CONCRETE MASONRY (CMU) CONCRETE PRECAST CONCRETE BRICK STONE STEEL ALUMINUM POROUS FILL SOIL RIGID INSULATION BATT INSULATION GYPSUM DRYWALL PLASTER OR SAND PLYWOOD FRAMING LUMBER FINISH WOOD CERAMIC TILE ACOUSTICAL PANELS LIGHTWEIGHT CONC. TOPPING 2'x2' LIGHT FIXTURE 2'x4' LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE EXIT SIGN PENDANT LIGHT FIXTURE EXHAUST FAN RETURN REGISTER SUPPLY DIFFUSER SECURITY CAMERA FLUSH MOUNTED PA SPEAKER SUSPENDED CEILING SYSTEM STRIP FLUORESCENT LIGHT FIXTURE EMERGENCY WALL MOUNTED LIGHT FIXTURE WITH BATTERY BACKUP - REFER TO ELEC. WALL MOUNTED LIGHT FIXTURE SPRINKLER DIRECTION OF SLOPE IN STRUCTURE DIRECTION OF SLOPE IN INSULATION DIRECTION OF SLOPE IN CRICKET WALK PAD SHEET SEQUENCE VIEW TYPE MODIFIER 0 = DEMOLITION PLANS (OPTIONAL) 1 = FLOOR PLANS 2 = REFELECTED CEILING PLANS 3 = FINISH PLANS 4 = FF&E PLANS VIEW TYPE 0 = GENERAL / SCHEDULES 1 = PLANS 2 = EXTERIOR ELEVATIONS & DETAILS 3 = OVERALL BUILDING & EXTERIOR WALL SECTIONS 4 = ENLARGED PLANS 5 = INTERIOR ELEVATIONS & CASEWORK 6 = DETAILS DISCIPLINE T = TITLE SHEET & INDEX G = GENERAL B = GEOTECHNICAL / ENVIRONMENTAL D = DEMOLITION SERIES C = CIVIL L = LANDSCAPE A = ARCHITECTURAL / INTERIORS I = INTERIORS S = STRUCTURAL F = FIRE PROTECTION P = PLUMBING M = MECHANICAL / HVAC E = ELECTRICAL X = OTHER 30" SITTING HEIGHT 34" ADA HEIGHT 36" STANDING HEIGHT 42" TRANSACTION HEIGHT 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:08:01 PMGENERAL DRAWING STANDARDS & NOTES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL 1. VERIFY ALL EXISTING CONDITIONS. 2. CONTRACTOR TO MAINTAIN EGRESS ROUTES FROM EXISTING BUILDING THROUGHOUT COURSE OF CONSTRUCTION. 3. VERTICAL DIMENSIONS ARE FROM "FLOOR LINE" UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS FOR "FLOOR LINE" DATUMS. 4. HORIZONTAL DIMENSIONS FOR NEW CONSTRUCTION ARE FROM FACE OF FINISH UNLESS OTHERWISE NOTED. HORIZONTAL DIMENSIONS FOR EXISTING CONSTRUCTION ARE FROM FACE OF EXISTING FINISHED SURFACE. 5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT WITH THE DESIGN PROFESSIONAL TO OBTAIN CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION. 6. HOLES CUT THROUGH EXISTING OR NEW FIRE RATED CONSTRUCTION FOR INSTALLATION OF PIPING, DUCTWORK, OR OTHER PENETRATIONS SHALL BE KEPT TO A MINIMUM NUMBER AND HELD TO A MINIMUM SIZE. FILL VOIDS BETWEEN PIPES, DUCTS, OTHER PENETRATING ITEMS AND RATED CONSTRUCTION WITH FIRE RETARDANT SEALANT SYSTEM LISTED IN THE UL FIRE RESISTANCE DIRECTORY WITH FIRE (F) AND TEMPERATURE (T) RATINGS EQUAL TO OR GREATER THAN THE FIRE RESISTANCE RATING OF THE ASSEMBLY BEING SEALED. 7. ALIGN NEW FLOOR FINISHES WITH EXISTING ADJACENT FLOOR FINISHES UNLESS OTHERWISE INDICATED WHERE NEW AND EXISTING FINISHED SURFACES ARE INDICATED TO BE ALIGNED, INSTALL SO FINISHED SURFACES ARE FLUSH (FEATHER MAXIMUM 1/8β PER FOUR FEET). 8. IT IS UNDERSTOOD AND AGREED THAT DRAWING REFINEMENTS, ADDITIONAL DETAILING AND CLARIFICATIONS WILL BE ISSUED DURING THE CONSTRUCTION SCHEDULE AND NO ADJUSTMENT WILL BE MADE IN THE CONTRACTORSβ OR SUB-CONTRACTORSβ PRICE UNLESS SUCH REFINEMENT, DETAILING OR CLARIFICATIONS RESULT IN CHANGES TO THE SCOPE, QUALITY, FUNCTION AND OR INTENT OF THE DRAWINGS AND THE PROJECT MANUAL NOT REASONABLY INFERABLE BY A CONTRACTOR OR SUB-CONTRACTOR EXPERIENCED IN THIS TYPE OF WORK. 9. ALL CONTRACTORS AND SUB-CONTRACTORS MUST QUOTE ON COMPLETED, FULLY OPERABLE SYSTEMS BASED ON THE DESIGN INTENT OF THE CONTRACT DOCUMENTS, AND ALL MATERIAL AND LABOR IMPLIED THEREFROM. 10. UNLESS OTHERWISE REQUIRED BY THE OWNER, CONSTRUCTION ADMINISTRATION SERVICES WILL BE COMPLETED USING NEWFORMA PROJECT CENTER. REFERENCE DIVISION 1 OF THE SPECIFICATION FOR THE PROCEDURES FOR REQUESTS FOR INFORMATION AND SUBMITTALS. LEGEND - GENERAL SYMBOLS LEGEND - PARTITION INDICATIONS LEGEND - MATERIAL INDICATIONS LEGEND - REFLECTED CEILING DEFINITION: THE TERM "DESIGN PROFESSIONAL" MEANS "ARCHITECT", "PROFESSIONAL ENGINEER", "INTERIOR DESIGNER" OR OTHER PARTY RESPONSIBLE FOR PROVIDING DESIGN SERVICES AS APPROPRIATE. 1. THE REFLECTED CEILING PLAN PROVIDES INFORMATION CONCERNING THE LOCATIONS OF LIGHTS, CEILING FIXTURES, HVAC GRILLES, ETC. REFER TO THE REFLECTED CEILING PLAN FOR LOCATIONS ONLY. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR APPLICABLE ENGINEERING INFORMATION. 2. SPRINKLER HEADS ARE NOT INDICATED. REFER TO PLUMBING DRAWINGS FOR SPRINKLER REQUIREMENTS AND INFORMATION. 3. CEILING FIXTURES INCLUDING GRILLES, DIFFUSERS, INCANDESCENT LIGHTS, ETC. ARE TO BE CENTERED IN ACOUSTIC CEILING PANELS UNLESS NOTED OTHERWISE. 4. ALL CEILING HEIGHTS NOTED ARE ABOVE FINISHED FLOOR (A.F.F.) NOTES - REFLECTED CEILING PLAN LEGEND - ROOF NOTES - TOBACCO FREE WORKZONE USE OF TOBACCO PRODUCTS IS NOT PERMITTED ANYWHERE ON OWNER'S PROPERTY. PROHIBIT USE OF ALL TOBACCO PRODUCTS, INCLUDING BUT NOT LIMITED TO CIGARETTES, CIGARS, PIPES, CHEWING TOBACCO, SNUFF, DIP, SNUS AND ELECTRONIC CIGARETTES BY ALL PERSONNEL COVERED BY THIS CONTRACT WHILE ON OWNER'S PROPERTY. THIS PROHIBITION APPLIES TO OCCUPANTS OF JOBSITE OFFICES, STORAGE OR WORK SHEDS, WORK AREAS ASSIGNED EXCLUSIVELY TO THE CONTRACTOR, AND VEHICLES WHILE THE VEHICLE IS ON OWNER'S PROPERTY. ENFORCE REQUIREMENTS STRICTLY. LVR LOUVER MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MLD MOLDING mm MILLIMETER MO MASONRY OPENING MT METAL THRESHOLD MTL METAL MULL MULLION MWK MILLWORK N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFF OFFICE OFOI OWNER FURNISHED OWNER INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPP H OPPOSITE HAND OVFL OVERFLOW #LBS POUNDS PAR PARALLEL PART PARTIAL PARTN PARTITION PERIM PERIMETER PERP PERPENDICULAR PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER, PLASTIC PLBG PLUMBING PLWD PLYWOOD PNL PANEL PNT PAINT PP PITCH POCKET PR PAIR PRV POWERED ROOF VENTILATOR PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED, PORCELAIN TILE PWC PLASTIC WALL COVERING QT QUARRY TILE QTY QUANTITY QUAL QUALITY R RISER RA RETURN AIR RAD RADIUS RB RUBBER, RUBBER BASE RD ROOF DRAIN REBAR REINFORCING BAR RECEP RECEPTACLE, RECEPTION REF REFERENCE REFL REFLECTED REFR REFRIGERATOR REG REGULAR REINF REINFORCED REP REPAIR REQ REQUIRE, REQUIRED RESIL RESILIENT REV REVISION RFG ROOFING RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING RT RIGHT S SOUTH SC SOLID CORE SCHED SCHEDULE SCUP SCUPPER SD SOAP DISPENSER SECT SECTION SHT SHEET SHWR SHOWER SIM SIMILAR SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SP STAND PIPE SPEC SPECIFICATION SPM SINGLE PLY MEMBRANE SS SERVICE SINK, STAINLESS STEEL SSM SOLID SURFACE MATERIAL ST STAINLESS STL STEEL STN STONE STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SYS SYSTEM T TREAD T GL TEMPERED GLASS T&G TONGUE & GROOVE TB TOWEL BAR TD TRENCH DRAIN TEL TELEPHONE TEMP TEMPERED, TEMPORARY TERR TERRAZZO THK THICK TLT TOILET TOC TOP OF CURB, TOP OF CONCRETE TOM TOP OF MASONRY TOS TOP OF STEEL TOSL TOP OF SLAB TTD TOILET TISSUE DISPENSER TWS THRU-WALL SCUPPER TYP TYPICAL UC UNDERCOUNTER, UNDERCUT UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER, VINYL BASE VC VALVE CABINET VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL VIT VITREOUS CHINA VNR VENEER VP VENT PIPE, VAPOR PROOF VTR VENT THRU ROOF VWC VINYL WALL COVERING W WIDTH W/ WITH W/O WITHOUT WAINS WAINSCOT WB WOOD BASE WC WALL COVERING, WATER CLOSET WD WOOD WG WIRE GLASS WH WATER HEATER WIN WINDOW WPR WATERPROOFING WPT WORK POINT WR WATER RESISTANT, WASTE RECEPTACLE WT WEIGHT WWF WELDED WIRE FABRIC @ AT A/C AIR CONDITIONING AB ANCHOR BOLT AC ACOUSTICAL ACP ACOUSTICAL CEILING PANEL AD ACCESS DOOR ADJ ADJACENT, ADJUSTABLE AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE AP ARMOR PLATE APPROX APPROXIMATE ARCH ARCHITECTURAL AWC ACOUSTICAL WALL COVERING BC BRICK COURSES(ING) BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BENCH MARK, BEAM BOT BOTTOM BRG BEARING BRK BRICK BSMT BASEMENT BUR BUILT UP ROOFING CB CATCH BASIN CF CUBIC FOOT (FEET) CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM CUBIC FOOT PER MINUTE CG CORNER GUARD CHAN CHANNEL CHR CHAIR RAIL CI CAST IRON CIP CAST IN PLACE CJ CONTROL JOINT CLG CEILING CLO CLOSET CLR CLEAR cm CENTIMETER CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMP COMPOSITION, COMPOSITE CONC CONCRETE CONT CONTINUOUS CORR CORRIDOR CP CLEAR PLASTIC CPT CARPET CR CRASH RAIL CR/BG CRASH RAIL / BUMPER GUARD CT CERAMIC TILE CTR CENTER CV CHECK VALVE CW CLEAR WIRE GLASS CY CUBIC YARD CYL CYLINDER Ρ€ CENTERLINE D DEPTH DBL DOUBLE DEG DEGREE DEMO DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DP DAMPROOFING DR DOOR, DRAIN DS DOWNSPOUT DWG DRAWING DWGS DRAWINGS EA EACH EB EXPANSION BOLT EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR, ELEVATION EMER EMERGENCY ENGR ENGINEER(ING) EPDM ETHYLENE PROPYLENE DIENE MONOMER (ROOF MEMBRANE) EQ EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EXIST EXISTING EXPA EXPANSION ANCHOR EXT EXTERIOR F FAHRENHEIT FA FIRE ALARM FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FHC FIRE HOSE CABINET FIN FINISH(ED) FO FINISHED OPENING FOF FACE OF FINISH FOS FACE OF STUD FRTW FIRE RETARDANT TREATED WOOD FV FIELD VERIFIED FWC FABRIC WALL COVERING GA GAGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GEN GENERAL GL GLASS, GLAZING GND GROUND GNV GOOSE NECK VENTILATOR GR GROUT GYP GYPSUM GYP BD GYPSUM BOARD H HIGH HB HOSE BIBB HC HOLLOW CORE HD HEAVY DUTY HDW HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HRL HANDRAIL HVAC HEATING VENTILATING & AIR CONDITIONING HWD HARDWOOD ID INSIDE DIAMETER IN INCH INSUL INSULATION INT INTERIOR IPT INTERIOR PAINT JAN JANITOR JCT JUNCTION JST JOIST JT JOINT JT B JOINT BACKER KB KEYBOARD KIT KITCHEN KO KNOCKOUT KP KICK PLATE KS KNEE SPACE L LENGTH LAM LAMINATE, LAMINATED LAM GL LAMINATED GLASS LAV LAVATORY LB POUND LBF POUNDS-FORCE LH LEFT HAND LIN LINEAR LLV LONG LEG VERTICAL LEGEND - ABBREVIATIONS 1. CONTRACTOR TO CONTACT OWNER PRIOR TO START OF DEMOLITION OF ANY AREAS TO ALLOW OWNER TO REMOVE ANY MOVABLE EQUIPMENT SO DESIRED. 2. REMOVE ALL FIRE EXTINGUISHERS AND CABINETS IN WALLS TO BE DEMOLISHED AND RETURN TO OWNER FOR FURTURE REUSE. 3. REPAIR HOLES IN EXISTING WALLS TO REMAIN WHERE WALL MOUNTED ITEMS ARE TO BE REMOVED. REFER TO ROOM FINISH LEGEND FOR FINAL FINISH. 4. PATCH, FILL, AND LEVEL ALL HOLES IN FLOOR SLAB DUE TO DEMOLITION OF PLUMBING RISERS, FLOOR DRAINS, ELECTRICAL RISERS, MILLWORK, CASEWORK, OR EQUIPMENT. 5. REPAIR ALL CEILINGS TO MATCH EXISTING CEILINGS WHERE WALLS ARE TO BE DEMOLISHED AND EXISTING CEILING IS TO REMAIN. 6. CONTRACTOR TO MATCH ALL EXISTING CONDITIONS FOR ALL REQUIRED MODIFICATIONS IN RENOVATED AREAS (U.N.O.). THIS REFERS TO REPETITIONS OF FINISH PATTERNS AND COLORS, MODIFICATIONS TO HANDRAILS AND BUMPER PANELS, ETC. 7. WHERE PARTITIONS, EQUIPMENT, OR ACCESSORIES, ETC. ARE REMOVED AND NO REPLACEMENT FINISH IS CALLED FOR, THE GENERAL CONTRACTOR SHALL REPAIR TO MATCH ADJACENT FINISH. 8. CONTRACTOR TO PROTECT FROM DAMAGE ALL EXISTING FLOORS, WALLS, CEILINGS, ETC. DURING CONSTRUCTION AND PROVIDE TEMPORARY PARTITIONS AS NEEDED. CONTRACTOR IS RESPONSIBILE FOR REPAIR AND REPLACEMENT OF ALL DAMAGED FLOORING, WALLS, CEILINGS, ETC. FINISHES TO MATCH EXISTING. 9. DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE DEMOLISHED. TYPICAL (U.N.O.) 10. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL DEMOLITION MATERIALS. TEMPORARY LIGHTING WILL BE PROVIDED BY THE CONTRACTOR. 11. REMOVE ALL FLOOR COVERINGS AND PREP CONCRETE DECK FOR NEW CARPET, VINYL AND CERAMIC TILE AS SCHEDULED. (TYPICAL - ALL ROOMS WITHIN LIMITS OF PROJECT) 12. REMOVE EXISTING CEILING GRID AND ASSOCIATED SUPPORT SYSTEM - RETURN EXISTING LIGHT FIXTURES TO OWNER (TYPICAL - ALL ROOMS WITHIN LIMITS OF PROJECT) 13. ADDITIONAL DEMOLITION MAY BE REQUIRED TO ACCOMMODATE NEW CONSTRUCTION SHOWN ON OTHER SHEETS. CONTRACTORS TO REVIEW EXISTING CONDITIONS AND INCLUDE IN BASE BID ALL DEMOLITION REQUIRED FOR A COMPLETE INSTALLATION. 14. REMOVE ALL EXISTING BASES AND VINYL WALL COVERINGS. PREPARE SURFACES TO ACCEPT NEW FINISHES, TYP. NOTES - GENERAL DEMOLITION NOTES - PATCH & REPAIR 1. FILL ALL HOLES IN FLOOR SLAB WITH CONCRETE AFTER REMOVAL OF PLUMBING LINES, DRAINS, PIPES, ETC. MAINTAIN REQUIRED FIRE RATINGS. 2. PATCH AND REPAIR HOLES IN EXISTING GYP BD PARTITIONS FROM REMOVED EQUIPMENT, MECHANICAL AND ELECTRICAL DEVICES AND OUTLETS, ATTACHMENTS, FURNISHINGS, ETC. 3. PATCH AND REPAIR ALL CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW MECHANICAL AND ELECTRICAL WORK. THIS WORK MAY EXTEND BEYOND BOUNDARIES INDICATING "PROJECT LIMITS" ON ARCHITECTURAL DRAWINGS. FINISHES SHALL MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED. 4. PATCH AND REPAIR ALL EXISTING FIREPROOFING DISTURBED DURING DEMOLITION AT COLUMNS AND BRACING TO MEET REQUIRED FIRE RATINGS. 5. PATCH AND REPAIR FINISHES WHERE EXISTING WALLS, PARTITIONS, DOORS, PLUMBING FIXTURES, OR CASEWORK HAVE BEEN REMOVED. FINISHES SHALL MATCH EXISTING, OR PROVIDE NEW AS SCHEDULED. LEGEND - DRAWING NUMBERS LEGEND - TYPICAL COUNTER HEIGHTS 10/17/2016 01/11/18 CLEAR FLOOR SPACE - RECTANGLE 30"x48" TURNING SPACE - CIRCULAR TURNING SPACE - T-SHAPED 5'-0" x > 24"ALCOVE CLEAR SPACE (FORWARD APPROACH) - RECTANGLE 36"x48" ALCOVE CLEAR SPACE (PARALLEL APPROACH) - RECTANGLE 30"x60"x > 15"ACCESSIBLE TURNING SPACE & CLEAR SPACE 5'-0" 2'-0"1'-0" 3'-0" 1'-0"5'-0"3'-0"4'-0"2'-6"4'-0"3'-0" 2'-6"5'-0" FRONT APPROACH POCKET OR HINGE APPROACHSIDE APPROACH STOP OR LATCH APPROACH DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS 3'-6"3'-6"3'-6"4'-0"2'-0" 1'-10" FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE (WITH CLOSER & LATCH) HINGE APPROACH, PULL SIDE (OPTION A) HINGE APPROACH, PULL SIDE (OPTION B) HINGE APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE (WITH CLOSER & LATCH) LATCH APPROACH, PULL SIDE (WITH CLOSER) LATCH APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE (WITH CLOSER) 32" MIN. FRONT APPROACH: HINGE APPROACH: LATCH APPROACH: LATCH APPROACH, PULL SIDE MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS & GATES 5'-0"1'-6" 4'-0"4'-0"1'-0"5'-0" 3'-0"4'-6"3'-6"3'-6"1'-10" 4'-0"1'-0" 1'-10"4'-0" 2'-0"4'-6" 2'-0" 2'-0" 3'-6"2'-0"4'-0"34" - 38"34" - 38"4'-0"MAX.1'-3"MIN.4'-0"MAX.3'-8"MAX.4'-0"MAX.4'-0"MAX.3'-10"MAX.2'-10"MAX.2'-10"MAX.1'-3"MIN. UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH HANDRAIL HEIGHT AT STAIRS HANDRAIL HEIGHT AT RAMPS X = TREAD DEPTH TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS X X 1'-0" MIN. 1'-0" MIN. 1'-0" MIN. 1'-8" MAX 2'-1" MAX 2'-3"MAX.6'-8"MIN. REDUCED VERTICAL CLEARANCE 10" MAX. 10" MAX. 2'-0" MAX. CARPET ON FLOOR SURFACES VERTICAL CHANGES IN LEVEL (a) BEVELED CHANGES IN LEVEL (b) BEVELED CHANGES IN LEVEL 1 2 1 21/2"1/4" MAX.1/4" - 1/2" MAX.1/2"1/4" 1/4"CLR.34"27" AFF MAX TO BOTOF REFLECTINGSURFACE OF MIRROR CLR27"34" MAX.AFF MAX TO BOTOF REFLECTINGSURFACE OF MIRRORMIN. 8"27" MIN.MIN.9"MAX. 6" MIN. 11"EMPLOYEE RESTROOM LAVATORY PUBLIC RESTROOM LAVATORY KNEE & TOE CLEARANCE AT LAVATORY ACCESSIBLE WATER CLOSET ACCESSIBLE WATER CLOSET ACCESSIBLE URINAL STANDARD URINAL DRINKING FOUNTAIN MAX. 12" 42" MIN.40"40" 15" MIN.7" - 9" 33" - 36"39" - 41" 18" MIN.39" - 41"17" - 19"18" MIN.39" - 41" 33" - 36"16" - 18" 36" 12" 24"44" AFF MAX.17" MAX.MIN. 13 1/2" EQ EQ EQ EQ 24"30" CLR MIN.38" - 43" SPOUT HT.16"27"31"36" SPOUT HT.48" MAX.DOOR OPERATED PUSH-BUTTON 54" MIN. TOILET ACCESSORY# 48" MAXTA-1 TA-2 TA-3 TA-4 TA-5 TA-6 TA-7 TA-8 TA-9 TA-10 TA-11 TA-12 TA-13 TA-14 ILLUSTRATION: ACCESSORY ITEM: RESPONSIBILITY: BLOCKING TYPE: GRAB BAR - 18" -- C2 GRAB BAR - 42" -- C2 GRAB BAR - 36" -- C2 SEAT COVER DISPENSER -- A1 WALL MOUNTED SOAP DISPENSER -- A1 MIRROR -- C1 HOOK -- C1 (OR DOOR MOUNTED) WALL BUMP -- A1 PAPER TOWEL DISPENSER -- A1 COMBINATION PAPER TOWEL DISPENSER -- A2 SANITARY NAPKIN DISPOSAL UNIT -- A1 BABY CHANGING STATION -- C2 TOILET TISSUE DISPENSER -- C1 VENDOR -- A1 SEAT COVER SURFACE COIN SLOT NOTE: EQUIPMENT INDICATED IN DIAGRAM MAY OR MAY NOT BE USED ON THIS PROJECT. REFER TO EQUIPMENT PLAN(S), INTERIOR ELEVATIONS, ETC. FOR LOCATION AND QUANTITIES OF ITEMS. CONFIRM WITH OWNER ALL REQUIREMENTS FOR OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI) ITEMS. MANUFACTURER: -- -- -- -- -- -- -- -- -- -- -- -- -- --39" - 41" MIN18"42" 36" MAX33" MIN36"36" MAX33" MIN48" MAX38" MAX38" MAX36"48" MAX48" MAX11"30" 48" MAXMIN 19"48" MAXMODEL NUMBER: -- -- -- -- -- -- -- -- -- -- -- -- -- -- TA-15 AIR BLADE -- A1 -- --41" MAX34" MAX27" MIN2 1/2" MAX.18" MIN.20" - 24"2" MAX.17" - 19" BENCH BACK SUPPORT AND SEAT HEIGHT 12" BACK OF WALL 42" MIN.12"DRESSING ROOM BENCH WITH BACK 42" MIN.20" - 24"DRESSING ROOM BENCH WITHOUT BACK 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:05:55 PMGENERAL ACCESSIBILITY STANDARDS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A002 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL ACCESSIBILITY BUILDING AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE AND 2009 ICC A117.1. DEFINITIONS: ACCESSIBLE: A SITE, BUILDING, FACILITY OR PORTION THEREOF THAT COMPLIES WITH THE REFERENCED CODES. ACCESSIBLE ROUTE: A CONTINUOUS, UNOBSTRUCTED PATH THAT COMPLIES WITH THE CODES. CIRCULATION PATH: AN EXTERIOR OR INTERIOR WAY OF PASSAGE FROM ONE PLACE TO ANOTHER FOR PEDESTRIANS. COMMON USE: INTERIOR OR EXTERIOR CIRCULATION PATHS, ROOMS, SPACES OR ELEMENTS THAT ARE NOT FOR PUBLIC USE AND ARE MADE AVAILABLE FOR THE SHARED USE OF TWO OR MORE PEOPLE. EMPLOYEE WORK AREA: ALL OR ANY PORTION OF ASPACE USED ONLY BY EMPLOYEES AND ONLY FOR WORK. CORRIDORS, TOILET ROOMS, KITCHENETTES AND BREAK ROOMS ARE NOT EMPLOYEE WORK AREAS. FACILITY: ALL OR ANY PORTION OF BULIDINGS, STRUCTURES, SITE IMPROVEMENTS, ELEMENTS AND PEDESTRIAN OR VEHICULAR ROUTES LOCATED ON THE SITE. PUBLIC ENTRANCE: AN ENTRANCE THAT IS NOT A SERVICE ENTRANCE OR A RESTRICTED ENTRANCE. PUBLIC-USE AREAS: INTERIOR OR EXTERIOR ROOMS OR SPACES THAT ARE MADE AVAILABLE TO THE GENERAL PUBLIC. RESTRICTED ENTRANCE: AN ENTRANCE THAT IS MADE AVAILABLE FOR COMMON USE ON A CONTROLLED BASIS, BUT NOT PUBLIC USE, AND THAT IS NOT A SERVICE ENTRANCE. SERVICE ENTRANCE: AN ENTRANCE INTENDED PRIMARILY FOR DELIVERY OF GOODS OR SERVICES. SITE: A PARCEL OF LAND BOUNDED BY A LOT LINE OR A DESIGNATED PORTION OF A PUBLIC RIGHT-OF-WAY WHEELCHAIR SPACE: A SPACE FOR A SINGLE WHEELCHAIR AND ITS OCCUPANT. SCOPING REQUIREMENTS: SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES. SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES SHALL BE EXEMPT FROM THESE REQUIREMENTS TO THE EXTENT SPECIFIED BELOW AND IN OTHER SECTIONS OF THE AFORE REFERENCED ACCESSIBILITY CODES. ACCESSIBILITY IS NOT REQUIRED IN BUILDINGS AND FACILITIES, OR PORTIONS THEREOF, TO THE EXTENT PERMITTED BY 2012 VCC SECTIONS 1104 THROUGH 1110. EXISTING BUILDINGS SHALL COMPLY WITH 2012 VIRGINIA REHABILITATION CODE SECTION 3409. SECTION 1103.2.3 - EMPLOYEE WORK AREAS: SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS 907.5.2.3.2, 1107 AND 1104.3.1 AND SHALL BE DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER AND EXIT THE WORK AREA. WORK AREAS OR PORTIONS OF WORK AREAS, THAT ARE LESS THAN 150 SQUARE FEET IN AREA AND ELEVATED 7 INCHES OR MORE ABOVE THE GROUND OR FINISHED FLOOR WHERE THE ELEVATION IS ESSENTIAL TO THE FUNCTION OF THE SPACE SHALL BE EXEMPT FROM ALL REQUIREMENTS. SECTION 1103.2.8 - LIMITED ACCESS SPACES: NONOCCUPIABLE SPACES ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES, FREIGHT ELEVATORS OR VERY NARROW PASSAGEWAYS ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1103.2.9 - EQUIPMENT SPACES: SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, REPAIR OR MONITORING OF EQUIPMENT ARE NOT REQUIRED TO BE ACCESSIBLE. SUCH SPACES INCLUDE, BUT ARE NOT LIMITED TO , ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL, ELECTRICAL OR COMMUNICATIONS EQUIPMENT ROOMS, PIPING OR EQUIPMENT CATWALKS, WATER OR SEWAGE TREATMENT PUMP ROOMS AND STATIONS, ELECTRIC SUBSTATIONS AND TRANSFORMER VAULTS, AND HIGHWAY AND TUNNEL UTILITY FACILITIES. SECTION 907.5.2.3.2 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE NOTIFICATION APPLIANCE CIRCUITS SERVING THE EMPLOYEE WORK AREAS SHALL BE INITIALLY DESIGNED WITH A MINIMUM OF 20 PERCENT SPARE CAPACITY TO ACCOUNT FOR THE POTENTIAL OF ADDING VISIBLE NOTIFICATION APPLIANCES IN THE FUTURE TO ACCOMMODATE HEARING IMPAIRED EMPLOYEES. SECTION 1007 - ACCESSIBLE MEANS OF EGRESS (REFERENCED ABOVE): ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. SECTION 1104.3.1 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL BE ACCESSIBLE ROUTES EXCEPTIONS: 1. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE WORK AREAS THAT ARE LESS THAN 300 SQUARE FEET IN SIZE AND DEFINED BY PERMANENTLY INSTALLED PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 2. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE USE AREAS, THAT ARE AN INTEGRAL COMPONENT OF EQUIPMENT, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 3. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EXTERIOR EMPLOYEE WORK AREAS THAT ARE FULLY EXPOSED TO THE WEATHER, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. SECTION 1105 - ACCESSIBLE ENTRANCES: AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE. EXCEPTIONS: 1. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO AREAS NOT REQUIRED TO BE ACCESSIBLE. 2. LOADING AND SERVICE ENTRANCES THAT ARE NOT THE ONLY ENTRANCE TO A TENANT SPACE. WHERE RESTRICTED ENTRANCES ARE PROVIDED TO A BUILDING OR FACILITY, AT LEAST ONE RESTRICTED ENTRANCE TO THE BUILDING OR FACILITY SHALL BE ACCESSIBLE. IF A SERVICE ENTRANCE IS THE ONLY ENTRANCE TO A BUILDING OR A TENANT SPACE IN A FACILITY, THAT ENTRANCE SHALL BE ACCESSIBLE. AT LEAST ONE ACCESSIBLE ENTRANCE SHALL BE PROVIDED TO EACH TENANT IN A FACILITY. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO TENANTS THAT ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES WHERE PARKING IS PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN COMPLIANCE WITH REFERENCED CODE SECTIONS AND TABLES. TEN PERCENT OF PATIENT AND VISITOR PARKING SPACES PROVIDED TO SERVE HOSPITAL OUTPATIENT FACILITIES SHALL BE ACCESSIBLE. FOR EVERY SIX OR A FRACTION OF SIX ACCESSIBLE SPACES, AT LEAST ONE SHALL BE A VAN-ACCESSIBLE PARKING SPACE. NOTHING IN THE REFERENCED STANDARDS IS INTENDED TO PREVENT THE USE OF DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED PROVIDED THEY RESULT IN EQUIVALENT OR GREATER ACCESSIBILITY AND SUCH EQUIVALENCY IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. THE AUTHORITY HAVING JURISDICTION SHALL PROVIDE AN APPROPRIATE REVIEW AND APPROVAL PROCESS TO ENSURE COMPLIANCE WITH ADOPTED STANDARDS. ADAAG AND ICC A117.1 ARE SUBJECT TO VARIOUS AND POSSIBLE CONTRADICTORY INTERPRETATIONS. THE ARCHITECT, THEREFORE, WILL USE REASONABLE PROFESSIONAL EFFORTS AND JUDGEMENTS TO INTERPRET APPLICABLE ACCESSIBILITY REQUIREMENTS AS THEY PERTAIN TO PHYSICAL BARRIERS AND AS THEY APPLY TO THE PROJECT. THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH ACCESSIBILITY REQUIREMENTS AND/OR THE REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS THAT APPLY TO THE PROJECT. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES STANDARDS - ACCESSIBLE CLEAR SPACE AND MANEUVERING CLEARANCES STANDARDS - FLOOR SURFACES STANDARDS - ACCESSIBLITY DIAGRAMS STANDARDS - TOILET ACCESSORY MOUNTING DIAGRAMS STANDARDS - TOILET FIXTURE MOUNTING DIAGRAMS STANDARDS - DRESSING ROOM CLEARANCES 01/11/18 CLEAR FLOOR SPACE - RECTANGLE 30"x48" TURNING SPACE - CIRCULAR TURNING SPACE - T-SHAPED 5'-0" x > 24"ALCOVE CLEAR SPACE (FORWARD APPROACH) - RECTANGLE 36"x48" ALCOVE CLEAR SPACE (PARALLEL APPROACH) - RECTANGLE 30"x60"x > 15"ACCESSIBLE TURNING SPACE & CLEAR SPACE 5'-0" 2'-0"1'-0" 3'-0" 1'-0"5'-0"3'-0"4'-0"2'-6"4'-0"3'-0" 2'-6"5'-0" FRONT APPROACH POCKET OR HINGE APPROACHSIDE APPROACH STOP OR LATCH APPROACH DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS 3'-6"3'-6"3'-6"4'-0"2'-0" 1'-10" FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE (WITH CLOSER & LATCH) HINGE APPROACH, PULL SIDE (OPTION A) HINGE APPROACH, PULL SIDE (OPTION B) HINGE APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE (WITH CLOSER & LATCH) LATCH APPROACH, PULL SIDE (WITH CLOSER) LATCH APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE (WITH CLOSER) 32" MIN. FRONT APPROACH: HINGE APPROACH: LATCH APPROACH: LATCH APPROACH, PULL SIDE MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS & GATES 5'-0"1'-6" 4'-0"4'-0"1'-0"5'-0" 3'-0"4'-6"3'-6"3'-6"1'-10" 4'-0"1'-0" 1'-10"4'-0" 2'-0"4'-6" 2'-0" 2'-0" 3'-6"2'-0"4'-0"34" - 38"34" - 38"4'-0"MAX.1'-3"MIN.4'-0"MAX.3'-8"MAX.4'-0"MAX.4'-0"MAX.3'-10"MAX.2'-10"MAX.2'-10"MAX.1'-3"MIN. UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH HANDRAIL HEIGHT AT STAIRS HANDRAIL HEIGHT AT RAMPS X = TREAD DEPTH TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS X X 1'-0" MIN. 1'-0" MIN. 1'-0" MIN. 1'-8" MAX 2'-1" MAX 2'-3"MAX.6'-8"MIN. REDUCED VERTICAL CLEARANCE 10" MAX. 10" MAX. 2'-0" MAX. CARPET ON FLOOR SURFACES VERTICAL CHANGES IN LEVEL (a) BEVELED CHANGES IN LEVEL (b) BEVELED CHANGES IN LEVEL 1 2 1 21/2"1/4" MAX.1/4" - 1/2" MAX.1/2"1/4" 1/4"CLR.34"27" AFF MAX TO BOTOF REFLECTINGSURFACE OF MIRROR CLR27"34" MAX.AFF MAX TO BOTOF REFLECTINGSURFACE OF MIRRORMIN. 8"27" MIN.MIN.9"MAX. 6" MIN. 11"EMPLOYEE RESTROOM LAVATORY PUBLIC RESTROOM LAVATORY KNEE & TOE CLEARANCE AT LAVATORY ACCESSIBLE WATER CLOSET ACCESSIBLE WATER CLOSET ACCESSIBLE URINAL STANDARD URINAL DRINKING FOUNTAIN MAX. 12" 42" MIN.40"40" 15" MIN.7" - 9" 33" - 36"39" - 41" 18" MIN.39" - 41"17" - 19"18" MIN.39" - 41" 33" - 36"16" - 18" 36" 12" 24"44" AFF MAX.17" MAX.MIN. 13 1/2" EQ EQ EQ EQ 24"30" CLR MIN.38" - 43" SPOUT HT.16"27"31"36" SPOUT HT.48" MAX.DOOR OPERATED PUSH-BUTTON 54" MIN. TOILET ACCESSORY# 48" MAXTA-1 TA-2 TA-3 TA-4 TA-5 TA-6 TA-7 TA-8 TA-9 TA-10 TA-11 TA-12 TA-13 TA-14 ILLUSTRATION: ACCESSORY ITEM: RESPONSIBILITY: BLOCKING TYPE: GRAB BAR - 18" -- C2 GRAB BAR - 42" -- C2 GRAB BAR - 36" -- C2 SEAT COVER DISPENSER -- A1 WALL MOUNTED SOAP DISPENSER -- A1 MIRROR -- C1 HOOK -- C1 (OR DOOR MOUNTED) WALL BUMP -- A1 PAPER TOWEL DISPENSER -- A1 COMBINATION PAPER TOWEL DISPENSER -- A2 SANITARY NAPKIN DISPOSAL UNIT -- A1 BABY CHANGING STATION -- C2 TOILET TISSUE DISPENSER -- C1 VENDOR -- A1 SEAT COVER SURFACE COIN SLOT NOTE: EQUIPMENT INDICATED IN DIAGRAM MAY OR MAY NOT BE USED ON THIS PROJECT. REFER TO EQUIPMENT PLAN(S), INTERIOR ELEVATIONS, ETC. FOR LOCATION AND QUANTITIES OF ITEMS. CONFIRM WITH OWNER ALL REQUIREMENTS FOR OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI) ITEMS. MANUFACTURER: -- -- -- -- -- -- -- -- -- -- -- -- -- --39" - 41" MIN18"42" 36" MAX33" MIN36"36" MAX33" MIN48" MAX38" MAX38" MAX36"48" MAX48" MAX11"30" 48" MAXMIN 19"48" MAXMODEL NUMBER: -- -- -- -- -- -- -- -- -- -- -- -- -- -- TA-15 AIR BLADE -- A1 -- --41" MAX34" MAX27" MIN2 1/2" MAX.18" MIN.20" - 24"2" MAX.17" - 19" BENCH BACK SUPPORT AND SEAT HEIGHT 12" BACK OF WALL 42" MIN.12"DRESSING ROOM BENCH WITH BACK 42" MIN.20" - 24"DRESSING ROOM BENCH WITHOUT BACK 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:08:06 PMGENERAL ACCESSIBILITY STANDARDS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A002a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL ACCESSIBILITY BUILDING AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE AND 2009 ICC A117.1. DEFINITIONS: ACCESSIBLE: A SITE, BUILDING, FACILITY OR PORTION THEREOF THAT COMPLIES WITH THE REFERENCED CODES. ACCESSIBLE ROUTE: A CONTINUOUS, UNOBSTRUCTED PATH THAT COMPLIES WITH THE CODES. CIRCULATION PATH: AN EXTERIOR OR INTERIOR WAY OF PASSAGE FROM ONE PLACE TO ANOTHER FOR PEDESTRIANS. COMMON USE: INTERIOR OR EXTERIOR CIRCULATION PATHS, ROOMS, SPACES OR ELEMENTS THAT ARE NOT FOR PUBLIC USE AND ARE MADE AVAILABLE FOR THE SHARED USE OF TWO OR MORE PEOPLE. EMPLOYEE WORK AREA: ALL OR ANY PORTION OF ASPACE USED ONLY BY EMPLOYEES AND ONLY FOR WORK. CORRIDORS, TOILET ROOMS, KITCHENETTES AND BREAK ROOMS ARE NOT EMPLOYEE WORK AREAS. FACILITY: ALL OR ANY PORTION OF BULIDINGS, STRUCTURES, SITE IMPROVEMENTS, ELEMENTS AND PEDESTRIAN OR VEHICULAR ROUTES LOCATED ON THE SITE. PUBLIC ENTRANCE: AN ENTRANCE THAT IS NOT A SERVICE ENTRANCE OR A RESTRICTED ENTRANCE. PUBLIC-USE AREAS: INTERIOR OR EXTERIOR ROOMS OR SPACES THAT ARE MADE AVAILABLE TO THE GENERAL PUBLIC. RESTRICTED ENTRANCE: AN ENTRANCE THAT IS MADE AVAILABLE FOR COMMON USE ON A CONTROLLED BASIS, BUT NOT PUBLIC USE, AND THAT IS NOT A SERVICE ENTRANCE. SERVICE ENTRANCE: AN ENTRANCE INTENDED PRIMARILY FOR DELIVERY OF GOODS OR SERVICES. SITE: A PARCEL OF LAND BOUNDED BY A LOT LINE OR A DESIGNATED PORTION OF A PUBLIC RIGHT-OF-WAY WHEELCHAIR SPACE: A SPACE FOR A SINGLE WHEELCHAIR AND ITS OCCUPANT. SCOPING REQUIREMENTS: SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES. SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES SHALL BE EXEMPT FROM THESE REQUIREMENTS TO THE EXTENT SPECIFIED BELOW AND IN OTHER SECTIONS OF THE AFORE REFERENCED ACCESSIBILITY CODES. ACCESSIBILITY IS NOT REQUIRED IN BUILDINGS AND FACILITIES, OR PORTIONS THEREOF, TO THE EXTENT PERMITTED BY 2012 VCC SECTIONS 1104 THROUGH 1110. EXISTING BUILDINGS SHALL COMPLY WITH 2012 VIRGINIA REHABILITATION CODE SECTION 3409. SECTION 1103.2.3 - EMPLOYEE WORK AREAS: SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS 907.5.2.3.2, 1107 AND 1104.3.1 AND SHALL BE DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER AND EXIT THE WORK AREA. WORK AREAS OR PORTIONS OF WORK AREAS, THAT ARE LESS THAN 150 SQUARE FEET IN AREA AND ELEVATED 7 INCHES OR MORE ABOVE THE GROUND OR FINISHED FLOOR WHERE THE ELEVATION IS ESSENTIAL TO THE FUNCTION OF THE SPACE SHALL BE EXEMPT FROM ALL REQUIREMENTS. SECTION 1103.2.8 - LIMITED ACCESS SPACES: NONOCCUPIABLE SPACES ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES, FREIGHT ELEVATORS OR VERY NARROW PASSAGEWAYS ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1103.2.9 - EQUIPMENT SPACES: SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, REPAIR OR MONITORING OF EQUIPMENT ARE NOT REQUIRED TO BE ACCESSIBLE. SUCH SPACES INCLUDE, BUT ARE NOT LIMITED TO , ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL, ELECTRICAL OR COMMUNICATIONS EQUIPMENT ROOMS, PIPING OR EQUIPMENT CATWALKS, WATER OR SEWAGE TREATMENT PUMP ROOMS AND STATIONS, ELECTRIC SUBSTATIONS AND TRANSFORMER VAULTS, AND HIGHWAY AND TUNNEL UTILITY FACILITIES. SECTION 907.5.2.3.2 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE NOTIFICATION APPLIANCE CIRCUITS SERVING THE EMPLOYEE WORK AREAS SHALL BE INITIALLY DESIGNED WITH A MINIMUM OF 20 PERCENT SPARE CAPACITY TO ACCOUNT FOR THE POTENTIAL OF ADDING VISIBLE NOTIFICATION APPLIANCES IN THE FUTURE TO ACCOMMODATE HEARING IMPAIRED EMPLOYEES. SECTION 1007 - ACCESSIBLE MEANS OF EGRESS (REFERENCED ABOVE): ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. SECTION 1104.3.1 - EMPLOYEE WORK AREAS (REFERENCED ABOVE): COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL BEACCESSIBLE ROUTES EXCEPTIONS: 1. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE WORK AREAS THAT ARE LESS THAN 300 SQUARE FEET IN SIZE AND DEFINED BY PERMANENTLY INSTALLED PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 2. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EMPLOYEE USE AREAS, THAT ARE AN INTEGRAL COMPONENT OF EQUIPMENT, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. 3. COMMON USE CIRCULATION PATHS, LOCATED WITHIN EXTERIOR EMPLOYEE WORK AREAS THAT ARE FULLY EXPOSED TO THE WEATHER, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. SECTION 1105 - ACCESSIBLE ENTRANCES: AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE. EXCEPTIONS:1. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO AREAS NOT REQUIRED TO BE ACCESSIBLE. 2. LOADING AND SERVICE ENTRANCES THAT ARE NOT THE ONLY ENTRANCE TO A TENANT SPACE. WHERE RESTRICTED ENTRANCES ARE PROVIDED TO A BUILDING OR FACILITY, AT LEAST ONE RESTRICTED ENTRANCE TO THE BUILDING OR FACILITY SHALL BE ACCESSIBLE. IF A SERVICE ENTRANCE IS THE ONLY ENTRANCE TO A BUILDING OR A TENANT SPACE IN A FACILITY, THAT ENTRANCE SHALL BE ACCESSIBLE. AT LEAST ONE ACCESSIBLE ENTRANCE SHALL BE PROVIDED TO EACH TENANT IN A FACILITY. AN ACCESSIBLE ENTRANCE IS NOT REQUIRED TO TENANTS THAT ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES WHERE PARKING IS PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN COMPLIANCE WITH REFERENCED CODE SECTIONS AND TABLES. TEN PERCENT OF PATIENT AND VISITOR PARKING SPACES PROVIDED TO SERVE HOSPITALOUTPATIENT FACILITIES SHALL BE ACCESSIBLE. FOR EVERY SIX OR A FRACTION OF SIX ACCESSIBLE SPACES, AT LEAST ONE SHALL BE A VAN-ACCESSIBLE PARKING SPACE. NOTHING IN THE REFERENCED STANDARDS IS INTENDED TO PREVENT THE USE OF DESIGNS, PRODUCTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED PROVIDED THEY RESULT IN EQUIVALENT OR GREATER ACCESSIBILITY AND SUCH EQUIVALENCY IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. THE AUTHORITY HAVING JURISDICTION SHALL PROVIDE AN APPROPRIATE REVIEW AND APPROVAL PROCESS TO ENSURE COMPLIANCE WITH ADOPTED STANDARDS. ADAAG AND ICC A117.1 ARE SUBJECT TO VARIOUS AND POSSIBLE CONTRADICTORY INTERPRETATIONS. THE ARCHITECT, THEREFORE, WILL USE REASONABLE PROFESSIONAL EFFORTS AND JUDGEMENTS TO INTERPRET APPLICABLE ACCESSIBILITY REQUIREMENTS AS THEY PERTAIN TO PHYSICAL BARRIERS AND AS THEY APPLY TO THE PROJECT. THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH ACCESSIBILITY REQUIREMENTS AND/OR THE REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS THAT APPLY TO THE PROJECT. SECTION 1106 - PARKING AND PASSENGER LOADING FACILITIES STANDARDS - ACCESSIBLE CLEAR SPACE AND MANEUVERING CLEARANCES STANDARDS - FLOOR SURFACES STANDARDS - ACCESSIBLITY DIAGRAMS STANDARDS - TOILET ACCESSORY MOUNTING DIAGRAMS STANDARDS - TOILET FIXTURE MOUNTING DIAGRAMS STANDARDS - DRESSING ROOM CLEARANCES 2 09/19/2016 CCD-002 10/17/2016 01/11/18 MAX 1'-0" MIN. 2'-0" MAX 2'-0"MIN.2'-0"30" CLEAR FLOOR SPACE ALONG LENGTH OF TUB COMPLIANT GRAB BAR, TA-17 BACK WALL HEAD ENDWALLCONTROLEND WALL2'-6"MAX 4"PORTABLE TUB SEAT: WINGITS #WHPTB265150PW TA-1 TA-17 SOAP DISH, TA-21 PF-7 T-17 TA-17 COMPLIANT AREA OF BATHTUB CONTROLS CL 4"3'-0" 4'-0"4" CONTROL END WALL TA-1 EQ EQ DIVERTER MOUNTED AT ACCESSIBLE HEIGHT 6'-10"6'-6" MINPF-7 4'-0" MAXTA-21 PF-5 PF-5 PF-7 SLIDER BAR TA-19, SHOWER CURTAIN ROD 6'-2"T-17 9"PORTABLE TUB BENCH3'-0"PLAN REFER TO PLAN REFER TO PLAN REFER TO BACK WALL TA-1 TA-17 TA-21 4'-0" MAXT-17 3'-0"HEAD END WALL TA-1 TA-19, SHOWER CURTAIN ROD 6'-2"2" MAX. 6" MAX. 30" CLEAR FLOOR SPACE ALONG LENGTH OF TUB CONTROL WALLEND WALL SIDE WALL 30" MIN.60" MIN.30" MIN. CL CLCL ACCESSIBLE FOLDING SHOWER SEAT: WINGITS #WSLX280225PWREV. TA-3 TA-17 SOAP DISH, TA-21 3'-0"SIDE WALL TA-19, SHOWER CURTAIN ROD CLEQ EQ 6'-10"PF-5 6'-2"38" MIN.CONTROL WALL 27" MAX.48" MAX.16" MIN 3'-0"PF-5 6'-6"DIVERTER MOUNTED AT ACCESSIBLE HEIGHT PF-7 HAND-HELD SHOWER SPRAY UNIT WITH 60" HOSE. SLIDER BAR TA-21 END WALL TA-19, SHOWER CURTAIN ROD TA-21 4'-0" MAX6'-2"CL BACK WALL HEAD END WALL CONTROL END WALL 1'-3"CL GRAB BAR, TA-16 SOAP DISH, TA-21 PF-4, LOW PROFILE SHOWER PAN BY BELSTONE OR EQUAL FOOTREST, TA-22, INTALL 15" AFF. CONTROL WALL 4'-0"TA-21 CL EQ EQ PF-5 BACK WALL TA-21 2'-6" 1'-3"TA-16 PF-4, LOW PROFILE SHOWER PAN BY BELSTONE OR EQUAL TA-20, BYPASS SHOWER DOOR, BELSTONE URBANITE OR EQUIVALENT REFER TO FINISH PLANS FOR SHOWER SURROUND 4'-0"CL FOOTREST, TA-22 1'-3"END WALL1'-3"GRAB BAR, TA-16 BACK WALL HEAD END WALL CONTROL END WALL 1'-9" CL CLSOAP DISH, TA-21 PF-7 CL CONTROL END WALL 4'-0"TA-21 EQ EQTA-19, SHOWER CURTAIN ROD PF-5 PF-76'-2"TA-16 BACK WALL 1'-9"2'-6"4'-0"TA-21 REFER TO FINISH PLANS FOR TUB SURROUND PF-7 CL HEAD END WALL 6'-2"TA-19, SHOWER CURTAIN ROD 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:08:10 PMACCESSIBLE & STANDARD SHOWER & TUB ENLARGED PLANS & ELEVATIONS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A002b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 2 09/19/2016 CCD-002 SCALE: 1/2" = 1'-0" DRAWING REF: A4304BACCESSIBLE TUB DETAILS & ACCESSORY MOUNTING LOCATIONS SCALE: 1/2" = 1'-0" DRAWING REF: A4324AACCESSIBLE SHOWER DETAILS & ACCESSORY MOUNTING LOCATIONS SCALE: 1/2" = 1'-0" DRAWING REF: A437b4CSTANDARD SHOWER DETAILS & ACCESSORY MOUNTING LOCATIONS SCALE: 1/2" = 1'-0" DRAWING REF: A4424DSTANDARD TUB DETAILS & ACCESSORY MOUNTING LOCATIONS 10/17/2016 01/11/18 DWREF.3'-10"6'-8"FIRE ALARM AUDIO/VISUAL DEVICES DOORBELL DISABLE SWITCH FINISHED FLOOR GUESTROOM SIDE OF DOOR SYMBOL DEVICE REMARKS BUTTON FOR DOOR SIGNAL 2-GANG BOX WITH TRANSFORMER FOR DOOR BELL DOORBELL DISABLE SWITCH HORN STROBE (VISUAL & AUDIBLE) FOR DOOR SIGNAL (BEDROOMS) REMOTE VISUAL STROBE DOOR SIGNAL (BATHROOMS) OUTSIDE DOOR ON STRIKE SIDE, +48" AFF FACTORY LABEL ON COVER PLATE MOUNT IN SOFFIT OR CABINET - PROVIDE ACCESS PROVIDE KEY SWITCH IN CORRIDOR ABOVE THE PUSH BUTTON TO TURN ON/OFF THE REQUIRED DOORBELL KIT. GANG WITH LIGHT SWITCH "DOORBELL DISABLE SWITCH" PLAQUE ON WALL BESIDE EVERY ENTRY DOOR, ROOM SIDE. MOUNT 80" AFF MOUNT 80" AFF HI-CF NOTES: PROVIDE ASSISTIVE LISTENING DEVICES IN THE REQUIRED NUMBER OF ROOMS PER BUILDING CODES AND DOJ 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. 1. DISTRIBUTE HEARING IMPAIRED ROOMS AMONGST ALL CLASSES OF ROOMS INCLUDING SUITES. 2. PLAQUES (EXCEPT AS NOTED): PROVIDE AS INDICATED. PLAQUES SHALL BE BLACK PHENOLIC WITH 1/4" WHITE ENGRAVED LETTERS. 3. PROVIDE TELEPHONE WITH VOLUME CONTROL AND SIGNAL NOTIFICATION LIGHT. 4. LOCATE TELEPHONES WITHIN 48" OF AN ELECTRICAL OUTLET. 5. PROVIDE EDWARDS 7005-65 HOTEL ROOM ANNUNCIATOR KIT WITH ADDITIONAL VISUAL STROBE AT EACH BATHROOM AND ADDITIONAL HORN STROBE AT EACH BEDROOM IN SUITES IN HI ROOMS. DEVICES FOR THE HEARING IMPAIRED COMPLIANT FEATURES: J PB J T DDS H A A SYMBOL DEVICE REMARKS SMOKE DETECTOR ELECTRICAL PANEL SMOKE DETECTOR WITH STROBE REMOVE EXISTING BATTERY POWERED SMOKE DETECTOR EXISTING ELECTRICAL PANEL PROVIDE SMOKE DETECTOR WITH STROBE HI NOTES: PROVIDE FIRE ALARM SYSTEM UPGRADES IN GUESTROOMS WITH HEARING IMPAIRED COMPLIANT FEATURES PER BUILDING CODES AND DOJ 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. 1. GUESTROOM FIRE ALARM (FA) ADDRESSABLE ANNUNCIATING DEVICES ARE CONNECTED TO EXISTING BUILDING FA PANEL IN THE HOTEL LOBBY. THEY ARE ACTIVATED BY EXISTING HARD-WIRED SMOKE DETECTORS, FA PULL STATION AND OTHER EXISTING SIGNALING DEVICES LOCATED IN GUEST BUILDING CORRIDORS AND STAIRWELLS. 2. GENERAL CONTRACTOR TO COORDINATE INSTALLATION OF NEW FA DEVICES WITH FIRE ALARM SYSTEMS VENDOR IF REQUIRED. 3. FIRE ALARM SYSTEMS VENDOR TO PROVIDE ADDITIONAL DOCUMENTATION REQUIRED BY LOCAL MUNICIPALITY / AUTHORITY HAVING JURISDICTION (AHJ) AND SECURE REQUIRED FA PERMITS. 4. SMOKE DETECTORS (HARDWIRED WITHIN ROOM): A - REMOVE EXISTING BATTERY POWERED SMOKE DETECTOR (SD) B - PROVIDE SDS WITH BATTERY BACK-UP (EXISTING SYSTEM COMPATIBLE) HARD-WIRED TO 120V POWER. SDS TO HAVE 520HZ, LOW FREQUENCY SOUNDER BASE, WHERE REQUIRED BY JURISDICTION PER NFPA 72. C - PROVIDE ADDITIONAL SDS DEVICES PER PLAN, INTER-CONNECTED TO PROVIDE NOTIFICATION THROUGHOUT GUESTROOM UNIT. 5. IF EXISTING FIRE ALARM DEVICES OR SMOKE DETECTORS ARE NOT WITHIN VISUAL SIGHT OF BED PILLOW, FIRE ALARM DEVICES AND SMOKE DETECTORS WILL BE RELOCATED TO BE WITHIN VISUAL SIGHT OF BED PILLOW. 6. ADDRESSABLE SMOKE DETECTORS: A - DISCONNECT & REMOVE EXISTING ADDRESSABLE SMOKE DETECTOR DEVICES. B - PROVIDE ADDRESSABLE SMOKE DETECTOR THAT IS COMPATIBLE WITH EXISTING BUILDING FIRE ALARM SYSTEM C - PROVIDE REMOTE SMOKE DETECTOR STROBE DEVICE PER PLAN, CONNECTED TO BUILDING SMOKE DETECTOR SYSTEM THROUGH ORIGINAL SMOKE DETECTOR HORN DEVICE WIRING D - IF EXISTING SMOKE DETECTORS AND STROBES ARE ADDRESSABLE, NEW SMOKE DETECTORS WILL BE ADDRESSABLE. IF EXISTING SMOKE DETECTORS ARE HARD WIRED WITHIN ROOMS ONLY, GC TO VERIFY WITH LOCAL FA VENDOR IF LOCAL JAA REQUIRES SMOKE DETECTORS & STROBES TO BE MADE ADDRESSABLE OR HARD WIRED. E - SUITE ROOMS TO HAVE REMOTE SMOKE DETECTOR STROBES IN ALL LIVING ROOM AREAS AND BEDROOMS. DEVICES FOR HI UPGRADES: SD EP SDS SMOKE STROBE, REMOTE PROVIDE REMOTE STROBE CONNECTED TO SMOKE DETECTORSS CORRIDOR SIDE OF DOOR3'-10"DOORBELL FINISHED FLOOR DOORBELL DISABLE KEY SWITCH H A A DDS J TJ PB TRANSFORMER LOCATION MAY VARY BY ROOM TYPE. ALWAYS ENDEAVOR TO HIDE FROM GUEST VIEW WHILE PROVIDING VENTILATION AND ACCESS FOR MAINTENANCE. LOCATE DOORBELL DISABLE SWITCH NEXT TO WELCOME LIGHT SWITCH - DO NOT GANG BOX. PROVIDE SEPARATE LABELED COVERPLATE (TYPICAL) A446b HAA DDSJT TRANSFORMER LOCATION MAY VARY BY ROOM TYPE. ALWAYS ENDEAVOR TO HIDE FROM GUEST VIEW WHILE PROVIDING VENTILATION AND ACCESS FOR MAINTENANCE. LOCATE DOORBELL DISABLE SWITCH NEXT TO WELCOME LIGHT SWITCH - DO NOT GANG BOX. PROVIDE SEPARATE LABELED COVERPLATE (TYPICAL) J PB UP TO LOFT LEVEL 6C 2D 2DHA AFROM LOWER LEVEL A445b 2B 5B 2D 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:08:16 PMHEARING IMPAIRED ROOM TYPES - PLANS, ELEVATION & LEGEND THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A003 2211 N FRONTAGE RD, VAIL, COLORADO 81657 1. DISCONNECT & REMOVE ONLY HI-CF DEVICES AND ALL ASSOCIATED WIRING. 2. PROVIDE BLANK COVER PLATES FOR REMAINING BACK BOXES. ALTERNATE: REMOVE BACK BOX AND PATCH WALL & FINISH TO MATCH EXISTING. 3. DO NOT RE-USE ANY HEARING IMPAIRED DEVICES REMOVED FOR DECOMMISSIONING. HI-CF DECOMMISSIONING NOTES: WHERE HI-CF ROOM IS DESIGNATED TO BE DECOMMISSIONED: ABBREVIATIONS: HI - CF: HEARING IMPAIRED - COMMUNICATION FEATURE HI - FA: HEARING IMPAIRED - FIRE ALARM SCALE: 3/8" = 1'-0"2D TYP DEVICE MOUNTING HEIGHTS PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE NOTED. SCALE: 3/8" = 1'-0"2E TYP DEVICE MOUNTING HEIGHTS SCALE: 1/4" = 1'-0"2A KING/QUEEN QUEEN/ KING SUITE HI-CF UPGRADE PLAN (TYPICAL) SCALE: 1/4" = 1'-0"4A KING CONDO LOWER LEVEL HI-CF UPGRADE PLAN (TYPICAL) SCALE: 1/4" = 1'-0"6A KING CONDO LOFT LEVEL HI-CF UPGRADE PLAN (TYPICAL) PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE NOTED. PLAN SHOWS NEW DEVICES ONLY, UNLESS OTHERWISE NOTED. 10/17/2016 01/11/18 DW DWREF.DWREF. REF DWREF. KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 QQ1L 205 KAL 204 KAR 203 K2 202 KSR 201 K1L 208 K1R 210 K1L 212 K1R 214 K1L 216 K1R 218 K1L 220 K1R 222 K1L 224 K1R 226 K1L 228 K1R 230 K1L 232 K1R 234 K1L 236 K1R 238 K3 206 (MODEL ROOM) (MODEL ROOM) SK-1 1 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 K1L 316 K1R 314 K1L 312 K1R 310 K1L 308 QA 306 KSR 301 KEXR 439 DKR 437 K4L 435 KKCON 433 K4L 431 KKCON 429 K4L 427 KKCON 425 K4L 423 KKCON 421 K4L 419 KKCON 417 K4L 415 KKCON 413 K4L 411 KKCON 409 K4L 407 KKCON 405 K4L 404 KCONR 403 KEXL 402 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434DKL 436 Q1 438 SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIMA451a 2B 6B 5B 4B A452 5C 2C 3C 4C A453 6B 2B 4B 5B A4535C 2C 4C 3CA500 4B 4C DKR+ 537 DKL+ 536 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:30:28 PMROOM SCHEDULE AND MATRIX THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A010 2211 N FRONTAGE RD, VAIL, COLORADO 81657 ROOM SCHEDULE ROOM TYPE DESCRITION & COUNT ROOM MATRIX ROOM COUNTTYPE TYPE DESCRIPTION DKL KING CONDO LEFT 1 DKR KING CONDO RIGHT 1 K1L 16 K1R 16 K2 KING (KING ACCESSIBLE DECOMMISSION) 1 K3 KING (FORMER GUEST LAUNDRY) 1 K4L KING LEFT 9 KAL KING ACCESSIBLE LEFT 1 KAR KING ACCESSIBLE RIGHT 1 KARI KING ACCESSIBLE ROLL-IN SHOWER 1 KCCON KING CORNER CONDO 1 KCONAL KING CONDO LEFT 1 KCONL 6 KCONR KING CONDO RIGHT 1 KEXL KING EXECUTIVE 1 KEXR KING EXECUTIVE 1 KKCON KING KING CONDO 8 KSR KING SUITE 2 Q1 7 QA 3 QQ1L QUEEN QUEEN LEFT 18 QQ1R QUEEN QUEEN RIGHT 18 QQARI QUEEN QUEEN ACCESSIBLE ROLL-IN SHOWER 1 116 ROOM NUMBER NAME 2ND FLOOR 201 KSR 202 K2 203 KAR 204 KAL 205 QQ1L 206 K3 207 QQ1R 208 K1L 209 QQ1L 210 K1R 211 QQ1R 212 K1L 213 QQ1L 214 K1R 215 QQ1R 216 K1L 217 QQ1L 218 K1R 219 QQ1R 220 K1L 221 QQ1L 222 K1R 223 QQ1R 224 K1L 225 QQ1L 226 K1R 227 QQ1R 228 K1L 229 QQ1L 230 K1R 231 QQ1R 232 K1L 233 QQ1R 234 K1R 235 QQARI 236 K1L 237 KARI 238 K1R 3RD FLOOR 301 KSR 302 QQ1L 303 QQ1R 304 QQ1L 305 QQ1R 306 QA 307 QQ1L 308 K1L 309 QQ1R 310 K1R 311 QQ1L 312 K1L 313 QQ1R 314 K1R 315 QQ1L 316 K1L 317 QQ1R 318 K1R 319 QQ1L 320 K1L 321 QQ1R 322 K1R 323 QQ1L 324 K1L 325 QQ1R 326 K1R 327 QQ1L 328 K1L 329 QQ1R 330 K1R 331 QQ1L 332 K1L 333 QQ1R 334 K1R 335 QQ1L 336 K1L 337 QQ1R 338 K1R 339 QQ1L 4TH FLOOR 401 KCCON 402 KEXL 403 KCONR 404 K4L 405 KKCON 406 QA 407 K4L 408 KCONL 409 KKCON 410 Q1 411 K4L 412 KCONL 413 KKCON 414 Q1 415 K4L 416 KCONL 417 KKCON 418 Q1 419 K4L 420 KCONL 421 KKCON 422 QA 423 K4L 424 KCONAL 425 KKCON 426 Q1 427 K4L 428 KCONL 429 KKCON 430 Q1 431 K4L 432 KCONL 433 KKCON 434 Q1 435 K4L 436 DKL 437 DKR 438 Q1 439 KEXR 5TH FLOOR 501 KCCON+ 503 KCONR+ 505 KKCON+ 508 KCON+ 509 KKCON+ 512 KCONL+ 513 KKCON+ 516 KCON+ 517 KKCON+ 520 KCON+ 521 KKCON+ 524 KCON+ 525 KKCON+ 528 KCON+ 529 KKCON+ 532 KCON+ 533 KKCON+ 536 DKL+ 537 DKR+ ROOM NUMBER BY TYPE 402 KEXR 439 KKCON 405 409 413 417 421 425 429 433 KSR 201 301 Q1 410 414 418 426 430 434 438 QA 306 406 422 QQ1L 205 209 213 217 221 225 229 302 304 307 311 315 319 323 327 331 335 339 QQ1R 207 211 215 219 223 227 231 233 303 305 309 313 317 321 325 329 333 337 QQARI 235 ROOM NUMBER BY TYPE DKL 436 DKR 437 K1L 208 212 216 220 224 228 232 236 308 312 316 320 324 328 332 336 K1R 210 214 218 222 226 230 234 238 310 314 318 322 326 330 334 338 K2 202 K3 206 K4L 404 407 411 415 419 423 427 431 435 KAL 204 KAR 203 KARI 237 KCCON 401 KCONAL 424 KCONL 408 412 416 420 428 432 KCONR 403 KEXL SCALE: 1/16" = 1'-0"5AREFERENCE PLAN - 2ND FLOOR SCALE: 1/16" = 1'-0"5B REFERENCE PLAN - 3RD FLOOR SCALE: 1/16" = 1'-0" DRAWING REF: A4525CREFERENCE PLAN - 4TH FLOOR HEARING IMPAIRED SCOPE OF WORK THE FOLLOWING ROOMS WILL BE PROVIDED WITH HARD WIRED HEARING ASSISTIVE COMMUNICATION FEATURES TO INCLUDE: DOORBELL/COVERPLATE AT ENTRY, DOORBELL HORN AND STROBE IN THE GUEST BATH, DOORBELL HORN AND STROBE IN THE SLEEPING AREA WITHIN VIEW OF THE BED, AND DOORBELL HORN AND STROBE IN ANY OTHER SEPARATE ROOMS OR AREAS WITHIN ROOM OR SUITE. THESE ITEMS ARE IN ADDITION TO NEW AUDIBLE AND NEW VISUAL HORN AND STROBE FOR BATHROOMS AND BEDROOMS FOR FIRE/SMOKE. FIRE/SMOKE ALARMS SHALL ANNUCIATE AT THE FIRE ALARM CONTROL UNIT AND SHALL INITIATE OCCUPANT NOTIFICATION UPON ACTIVATION, IN ACCORDANCE WITH NFPA: 233, 234, 301, 302, 334, 335, 402, 421, 432, 434, 435 THE FOLLOWING ACCESSIBLE ROOM WILL BE PROVIDED WITH ALL THE EQUIPMENT LISTED ABOVE: 203. REFER TO A003. 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 GRAND TOTAL: SCALE: 1/16" = 1'-0" DRAWING REF: A5015DREFERENCE PLAN - 5TH FLOOR/ 4TH FLOOR LOFT 9 08/02/2017 01/11/18 LINE OF STRUCTURE LINE OF CEILING LINE OF STRUCTURE FACE OF CMU, CONC, OR EXIST WALL F AW FACE OF CMU, CONC, OR EXIST WALL 3/4" WOOD FURRING STRIPS FINISH MATERIAL PARTITION GRAPHIC 3 HR SMOKE COMPARTMENT BARRIER 2 HR SMOKE COMPARTMENT BARRIER 2 HR FIRE BARRIER 1 HR SMOKE COMPARTMENT BARRIER 1 HR FIRE BARRIER NON-RATED SMOKE RESISTIVE PARTITION 3 HR FIRE BARRIER NON-RATED PARTITION (F) (H) (E) (D) (C) (B) (G) (a) UNDERSIDE OF DECK OR SLAB ROOF/FLR. 22 GA. MTL TOP TRACK (TYP. U.N.O.) CEILING LINE MOUNTING DETAIL B 22 GA. BOTTOM TRACK (TYP.) FLOOR LINE 18 GA. STUDS AT WALL MOUNTED ARCHITECTURAL CABINETS / MILLWORK / ATTACHED SHELVING AND STONE VENEER 4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX. 4'-6" MAX. 8'-6" MAX. DOUBLE STUDS DOUBLE STUDS ABOVE CEILING OPENING LARGE ABOVE CEILING OPENING DOOR OPENING DOUBLE DOOR OPENING BELOW CEILING OPENING LARGE BELOW CEILING OPENING NOTES: 1. ALL STUDS ARE SPACED 16" O.C. MAXIMUM. 2. ALL STUDS SHALL BE "C" STUDS WITH 1/4" FLANGE MINIMUM. 3. DENOTES SHELVING OR CABINETRY. 4. STUDS BEHIND BASE CABINETRY MAY BE TYPICAL STUDS. 5. IN NO CASE SHALL DOUBLE STUDS AT SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEMS. 06 03 01 05 02 05 01 03 04 01 TYPICAL FRAMING DOUBLE STUDS DOUBLE STUDS3'-2 7/8" LOWER PRIORITY WALL HIGHER PRIORITY WALL PARTITION PRIORITY LEGEND NOTE: MAINTAIN SHEATHING ON HIGHER PRIORITY WALL AT INTERSECTION WITH LOWER PRIORITY WALL AS INDICATED. FOR WALL PRIORITIES REFERENCE PARTITION PRIORITY LEGEND. * TABLE DOES NOT INCLUDE 3 AND 4 HOUR RATED PARTITIONS PRIORITY 1 - HIGHEST PRIORITY 2 PRIORITY 2 PRIORITY 3 PRIORITY 4 PRIORITY 5 - LOWEST ONE HOUR CONSTRUCTION TAPE & JT COMP., TYP. JAMB STUDS AS REQ'D.HOLLOW METAL FRAME 3 5/8" METAL STUDS 5/8" TYPE "X" GYP. BD TWO HOUR CONSTRUCTION HIGHER PRIORITY WALL 1 LAYER AT ONE HOUR SMOKE PARTITION LOWER PRIORITY WALL HIGHER PRIORITY WALL CORNER BEAD, TYP. 3 5/8" METAL STUD LOCATED AT ABUTTING WALL AND ATTACHED THRU GYPSUM WALLBOARD TO STUD OF ABUTTING WALL 5/8" GYPSUM WALLBOARD - NUMBER OF LAYERS PER PARTITION TYPE GYPSUM WALLBOARD 3 5/8" METAL STUD LOCATED AT ABUTTING WALL AND ATTACHED THRU GYPSUM WALLBOARD TO STUD OF ABUTTING WALL TAPE & JOINT COMPOUND TWO HOUR FIRE & SMOKE PARTITION TWO HOUR FIRE PARTITION TWO HOUR SHAFT PARTITION ONE HOUR FIRE & SMOKE PARTITION ONE HOUR FIRE PARTITION NON RATED PARTITION CONTINUE 2" WIDE x 22 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD WHERE GYP BD IS CONCURRENT WITH DECK FLUTE RECESS, EXTEND UP INTO RECESS AS SHOWN EXTEND ONE LAYER UP INTO FLUTE RECESS AND SEAL 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO STEEL DECK AT 12" O.C. MAX. WHEN PARTITION IS ALIGNED AT DECK FLUTE RECESS - PROVIDE CONTINUOUS 10" 22 GA MTL PLATE AT DECK FLUTE RECESS THAT IS CONTIGUOUS WITH PARTITION - ATTACH METAL PLATE TO DECK WITH POWER DRIVEN FASTENERS SEAL ONE SIDE OF PARTITION AGAINST PASSAGE OF SMOKE CONTINUE 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL - ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO PLATE OR STEEL DECK AT 12" O.C. MAX. CONTINUE 2" WIDE x 22 GA MTL STRAP, ATTACH GYP BD TO STRAP AT 8" O.C. MAX. CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE. RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. FILL DECK FLUTE RECESS WITH SAFING INSULATION - CAP ENDS OF INSULATION WITH 1/2" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE., RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. CAP ENDS OF INSULATION WITH 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL - ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. FILL DECK FLUTE RECESS WITH SAFING INSULATION FILL DECK FLUTE RECESS WITH SAFING INSULATION 1/2" THICK FIRE/SMOKE RESISTANT FILL MATERIAL. FILL DECK FLUTE RECESS (BOTH SIDES) POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) ONE HOUR RATED (UL-HW-D-0001) NON-RATED OR SMOKE RESISTANT CONT. 2" WIDE x 22 GA MTL STRAP, ATTACH GYP BD TO STRAP AT 8" O.C. MAX. 22 GA MTL TRACK WITH 2" FLANGES - ATTACH TO PLATE OR STEEL DECK AT 12" O.C. MAX. TWO HOUR RATED (UL-HW-D-0002) CONTINUE 10" WIDE x 22 GA MTL PLATE AT EACH DECK FLUTE. RECESS CONTIGUOUS WITH PARTITION - ATTACH TO DECK WITH POWER DRIVEN FASTENERS AT 12" O.C. MAX. CAP ENDS OF INSULATION WITH 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL WHERE PARTITION TERMINATES OR CHANGES DIRECTION ATTACH PLATE OR STEEL DECK AT 12" O.C. MAX. CMU PARTITION - DEPENDING ON HOW COURSING INTERSECTS THE STEEL DECK, THE TOP COURSE OF BLOCK MAY BE REQUIRED TO BE CUT FILL DECK FLUTE RECESS W/ SAFING INSULATION CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" x 2 1/2" PIECE OF GYP BD USED FOR THE WALL POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) POWER DRIVEN STEEL FASTENERS AT 12" O.C. MAX. (TYPICAL FOR ANGLES BOTH SIDES) 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL. FILL DECK FLUTE RECESS (BOTH SIDES) 1" THICK FIRE/SMOKE RESISTANT FILL MATERIAL TWO HOUR RATED (UL-HW-D-0009) CONT. 22 GA 2 1/2" x 2 1/2" MTL ANGLE WITH 2 1/2" WIDE PIECE OF GYP BD USED FOR THE WALL DOUBLE 20 GA. METAL STUDS 22 GA. METAL TRACK 1" x 22GA. METAL STRAP PLATES AT 3'-6" O.C. EACH SIDE CLIP ANGLE - 18 GA. x 1 1/2" x 11/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE E22 GA. METAL SILL TRACK BELOW 20 GA. METAL STUDS 22 GA. METAL TRACK DOUBLE 20 GA. METAL STUDS AT BOTH JAMBS 22 GA. METAL SILL TRACK BELOW 1" x 22 GA. METAL STRAP PLATES AT 3'- 6" O.C. EA. SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE DOUBLE 18 GA. 3 5/8" OR 6" METAL STUDS 22 GA. METAL TRACK CLIP ANGLE - 18 GA. x 1 1/2" x 1 1/2" x 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 0604 03 01 02 05 TYPICAL FRAMING DETAILS 2 3/4" C.J. GYP. BD. SUSPENDED CEILING SYSTEM 24'-0" MAX 24'-0" MAX GYPSUM BOARD CEILING INTERIOR PARTITION NON-EXPOSED EDGE PARTITION INTERSECTION/ CHANGE IN CONSTRUCTION LINE OF PARTITION SEALANT AND BACKER ROD L-BEAD SOUND ATTENUATION BLANKET COMPRESSED TO FILL OPENING AT SOUND RATED PARTITION PARTITION 1/4" BACKER ROD & SEALANT "LC" BEAD PARTITION LINE OF PARTITION 3/8" NON-RATED DETAILS 11/16" 1/2" MAX5/8"METAL TRIM CONTROL JOINTS EA SIDE METAL STUDS W/ 5/8" TYPE "X" GYP. BD. EA. SIDE 2 LAYERS OF 5/8" GYP. BD. SOUND ATTENUATION BLANKET, WHERE PARTITION CALLS FOR INSULATION 1 HR. RATED GYP. CONTROL JOINT REF PARTITION TYPE FOR INSULATION METAL TRIM CONTROL JOINTS EA SIDE METAL STUDS W/ 2 LAYERS 5/8" TYPE "X" GYP. BD. EA. SIDE 5/8"1/2" MAX2 HR. RATED GYP. CONTROL JOINT REF PARTITION TYPE FOR INSULATION RATED DETAILS TELEPHONE OR ELECTRICAL BOXES 1/2" OR 5/8" TYPE "X" GYP. BD. AS REQUIRED FOR TWO HOUR RATED FIRE OR SMOKE WALL TYPICAL STEEL STUD EACH 16 SQ. IN. MAX. TOTAL OPENING 100 SQ. IN./100 SQ. FT. (PER) UL 2'-0" MIN. SEAL BOXES WITH JOINT COMPOUND A = MTL STUD; DECK TO DECK; (1) LAYER GYP BD EA SIDE B = MTL STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE C = MTL STUD CHASE WALL; DECK TO DECK; (1) LAYER GYP BD EA SIDE D = MTL STUD; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD EA SIDE E = MTL STUD; PARTIAL HEIGHT; TO CEILING; (1) LAYER GYP BD EA SIDE F = MTL STUD FURRING; DECK TO DECK; (1) LAYER GP BD ON FINISH FACE G = MTL STUD FURRING; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD ON FINISH FACE L = MTL STUD; DECK TO DECK; (1) LAYER LEAD LINED GYP BD ON FINISH SIDE 'A'; (1) LAYER GYP BD ON FINISH SIDE 'B' M = CMU; DECK TO DECK N = CMU; PARTIAL HEIGHT; 6" ABOVE CEILING P = MTL STUD W/ STL ANGLE POSTS AT 4'-0" OC; PARTIAL HEIGHT; BELOW CEILING; (1) LAYER GYP BD EA SIDE S = MTL C-H STUD SHAFT WALL; DECK TO DECK; (1) LAYER GYP BD ON ROOM FINISH SIDE; (1) LAYER 1" SHAFT WALL LINER ON SHAFT SIDE T = MTL C-H STUD SHAFT WALL; DECK TO DECK; (2) LAYERS GYP BD ON ROOM FINISH SIDE; (1) LAYER 1" SHAFTWALL LINER ON SHAFT SIDE U = UNKNOWN PARTITION COMPOSITION W = WD STUD; DECK TO DECK; (1) LAYER GYP BD EA SIDE X = WD STUD; DECK TO DECK; (2) LAYERS GYP BD EA SIDE Y = WD STUD; PARTIAL HEIGHT; 6" ABOVE CEILING; (1) LAYER GYP BD EA SIDE Z = WD STUD; PARTIAL HEIGHT; TO CEILING; (1) LAYER GYP BD EA SIDE PARTITION TYPE PARTITION TYPE NOMINAL WIDTH FIRE OR SMOKE RATING SEE NOMINAL WIDTH SCHEDULE BELOW SEE PARTITION GRAPHIC LEGEND BELOW DESIGNATION AS NOTED ON PARTITION TYPE BELOW PARTITION DESIGNATOR MTL. STUD GYP. BD. DETAIL "A1" CONT. 20 GA. 4" WIDE MTL. BACK-UP PLATE DETAIL "A2" CONT. 18 GA. 8" WIDE MTL. BACK-UP PLATE 3 5/8" MIN. (DEEPER IF REQUIRED)14 GA. STL RUNNER TRACK -- CLIP FLANGES TO FIT OVER STUDS MTL WALL STUDS 2x8 (MIN.) WD. BLOCKING BETWEEN STUDS (DEEPER IF REQUIRED) CONT. 20 GA. 6" WIDE MTL BACK-UP PLATE (4) #2 WOOD SCREWS EACH END (3) 1/4"x3" WOOD SCREWS EACH ENDREFER TYPICALMOUNTING HEIGHTSREFER TYPICALMOUNTING HEIGHTSREFER TYPICALMOUNTING HEIGHTSMIN. 18 GA. MTL STUDS DETAILS "A1 & A2" (SECTION VIEW) DETAIL "B" (ISOMETRIC VIEW) DETAILS "C1 & C2" (ISOMETRIC VIEW) C1: WOOD BLOCKING ONLY C2: WOOD BLOCKING W/ METAL BACK-UP PLATE 11 METAL STUD CMU 7/8" 1 5/8" 2 1/2" 3 5/8" 4" 6" N/A 11 5/8" 3 5/8" 5 5/8" 7 5/8" 9 5/8" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WOOD STUD N/A N/A N/A 3 1/2" 5 1/2" N/A 7 1/4" N/A N/A N/A N/A N/A 'U' WIDTH RANGE 0 - .99" 11" - 11.99" 3" - 3.99" 5" - 5.99" 7" - 7.99" 9" - 9.99" 1" - 1.99" 2" - 2.99" 4" - 4.99" 6" - 6.99" 8" - 8.99" 10" - 10.99" N/A # 12 10 9 8 7 6 5 4 3 2 1 N/AN/A 0 N/A 12" - 12.99" NOMINAL WIDTH SCHEDULE 1 A 2 3 456 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:30:37 PMPARTITION TYPES, DETAILS, AND STANDARDS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A020 2211 N FRONTAGE RD, VAIL, COLORADO 81657 TYPE CONSTRUCTION DATA FIRE PARTITIONS STC RATING FRAMING / CORE SIZE OVERALL PARTITION WIDTH RATING UL DESIGNATION A - MTL STUD; DECK TO DECK; (1) LAYER FINISH MATERIAL EA SIDE A2a 2 1/2" 3 3/4" 0 HR A4a 3 5/8" 4 7/8" 0 HR A4b 3 5/8" 5 3/4" 0 HR A6a 6" 7 1/4" 0 HR A9a 3 5/8" / 6" 10 7/8" 0 HR F - MTL STUD FURRING; DECK TO DECK; (1) LAYER GYP BD ON FINISH FACE F1a 7/8" 1 1/2" 0 HR F2a 1 5/8" 2 1/4" 0 HR F3a 2 1/2" 3 1/8" 0 HR F4a 3 5/8" 4 1/4" 0 HR G6a 4 5/8" 6 5/8" 0 HR W - WOOD FURRING STRIPS; DECK TO DECK; (1) LAYER FINISH MATERIAL ON FINISH FACE W1a 3/4" 1 1/2" 0 HR NOTES - PARTITION TYPE 1. CONSTRUCTION OF FIRE RATED PARTITIONS SHALL BE IN ACCORDANCE WITH THE TESTING DESIGN DESIGNATED. ARCHITECTURAL DETAILS MAY NOT INDICATE EVERY REQUIRED COMPONENT OF TESTED ASSEMBLY. 2. PROVIDE CONTROL JOINTS IN ALL GYPSUM WALLBOARD PARTITIONS AT 30'-0" OC MAXIMUM OR AS INDICATED ON FLOOR PLANS. 3. ONE SIDE OF GYPSUM WALLBOARD MAY BE INSTALLED WHEN UNUSED SPACE (IE, UNDER STAIR) OR UNFINISHED TENANT SPACE EXISTS ON ONE SIDE, EXCEPT WHERE REQUIRED FOR FIRE RATING. 4. ALL STUD/ SPACING SHALL BE 16" OC UNLESS OTHERWISE NOTED. 5. PARTITION SYMBOL INDICATIONS ON FLOOR PLANS DESIGNATE THE ENTIRE LENGTH OF WALL INDICATED UNLESS INTERRUPTED BY ANOTHER SYMBOL. 6. UTILIZE EXTENDED TRACKS WITH SLOTTED HOLES AT TOPS OF PARTITIONS WHEREVER ATTACHING TO STRUCTURE ABOVE TO ALLOW FOR DEFLECTION. 7. PROVIDE FIRE BLOCKING FOR ALL PARTITIONS OPEN TO CEILING CAVITY. UTILIZE GYPSUM WALLBOARD WITH STEEL FRAMING WHERE SPACE IS TOO WIDE FOR SOLID STEEL OR INSULATION TYPE FIRE BLOCKING, UNLESS OTHERWISE INDICATED. PROVIDE IMPALING CLIPS WHERE REQUIRED TO SUPPORT INSULATION FIRE BLOCKING. 8. THE PARTITION TYPE SCHEDULE INCLUDES ONLY NEW PARTITIONS WITHIN THE SCOPE OF WORK. 9. SUBSTITUTE MOISTURE RESISTANT BOARD (PURPLE BOARD) FOR WET LOCATIONS (TOILETS, LOCKER ROOMS) OR WHERE SCHEDULED TO RECEIVE CERAMIC TILE OR STONE. FOR OTHER WET APPLICATIONS SUCH AS SHOWERS, USE CEMENTITIOUS TILE BACKER BOARDS. 10. ALL GYPSUM BOARDS SHALL BE 5/8" THICK AND HELD OFF 1/2" FROM FLOOR SURFACE, UNO. 11. PROVIDE CONTINUOUS SEALANT UNDER METAL TRACKS AND AT PERIMETER OF GYPSUM BOARD PANELS AT SMOKE RATED, STC RATED OR FIRE RATED ASSEMBLIES. 12. PROVIDE MARKINGS ABOVE SUSPENDED CEILINGS AND IN CONCEALED SPACES TO IDENTIFY FIRE RATED PARTITIONS. SUCH SIGNAGE SHALL BE 1" HIGH (MIN) LETTERS AND SHALL STATE "FIRE RATED ASSEMBLY" AT HORIZONTAL INTERVALS OF 8 FT. 13. METAL STUD PARTITIONS SCHEDULED TO SUPPORT WALL MOUNTED CASEWORK OR EQUIPMENT SHALL HAVE 33 MIL (20 GA) MIN STUDS FOR THE ENTIRE LENGTH OF THE CASEWORK. 14. PROVIDE WOOD OR METAL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING CASEWORK, GRAB BARS, SHELVING, HANDRAILS, TOILET PARTITIONS, ETC. REF TYP DETAILS FOR BLOCKING. 15. PROVIDE DOUBLED 33 MIL (20 GA) MIN STUDS AROUND ALL DOOR, WINDOW OR CASED OPENINGS. 16. ALL GYPSUM BOARD FOR FIRE RATED PARTITIONS SHALL BE "TYPE X", UNLESS OTHERWISE REQUIRED BY RATING DESIGN DESIGNATION. 17. REF. ENLARGED DETAILS AT TOPS OF FIRE RATED PARTITION HEAD DETAILS. 18. ORIENTATION OF SHAFT WALL ASSEMBLY MAY VARY FROM THAT SHOWN ON DRAWINGS AND MAY BE DETERMINED ON SITE AS REQUIRED AFTER CONSIDERATION IS MADE FOR STRUCTURAL OBSTRUCTIONS THAT PREVENT THE PROPER FASTENING OF GYPSUM BOARD. 19. WHERE INSULATION IS INDICATED, PROVIDE SOUND ATTENUATION BLANKETS (THERMAFIBER OR EQUAL). THERMAL FIBERGLASS INSULATION NOT ACCEPTABLE. 20. STC RATINGS ARE SHOWN FOR KNOWN TEST ASSEMBLIES FOR THE STUD SIZE INDICATED. FOR OTHER STUD SIZES COMPLY WITH REQUIREMENTS OF CLOSEST SIMILAR ASSEMBLY. 21. ALL PENETRATIONS IN FULL HEIGHT PARTITIONS SHALL BE SMOKE RESISTIVE AND FIRESTOPPED REGARDLESS OF THE PARTITION RATING. 22. PARTIAL-HEIGHT INSULATED PARTITIONS SHALL RECEIVE 1-LAYER OF CONTINUOUS 3" SOUND ATTENUATION BLANKETS ON TOP OF CEILING, EXTENDING 4'-0" FROM EACH SIDE OF PARTITION FACE, UNLESS OTHERWISE INDICATED. 23. FIRE-RATED PARTITIONS SHALL RECEIVE LISTED AND LABELED FIRE-RATED SEALANT SYSTEM (EACH SIDE) AT CONNECTION WITH UNDERSIDE OF STRUCTURAL DECK OR FIRE-PROOFED CEILING AND WITH FLOOR STRUCTURE. 24. ALL INTERIOR PARTITIONS SHALL RECEIVE BASE FINISH AS SCHEDULED, UNO. 25. ALL FULL-HEIGHT PARTITIONS TO RECEIVE CONTINUOUS SEALANT AT GAP BETWEEN GYP BD & STRUCTURE ABOVE, UNO. 26. CHASE WALL PARTITIONS SHALL RECEIVE 2 1/2" MTL STUD BRACES OR GYP GUSSET CONNECTING STUDS SPACED VERTICALLY 4'-0" OC, UNO. 27. PARTIAL HEIGHT MTL STUD PARTITIONS AT OR ABOVE CEILING HEIGHT SHALL RECEIVE CONTINUOUS STUD TOP TRACK W/ 2 1/2" 33 MIL (20 GA) MTL STUD BRACES AT 4'-0" OC MAX, ALTERNATING SIDES, UNO. 28. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE 'L' BEAD AT GYP BD CEILING CONNECTION, UNO. 29. ALL CEILING-HEIGHT MTL STUD PARTITIONS SHALL RECEIVE PARTITION CLIP FOR ATTACHMENT W/ DIAGONAL BRACING ABOVE CEILING, UNO. PROVIDE DIAGONAL BRACING FOR ACOUSTICAL CEILING PANELS. 30. ALL LEAD-LINED GYP BD TO EXTEND 7'-0" AFF, UNO. 31. ALL FULL-HEIGHT MASONRY PARTITIONS TO RECEIVE COMPRESSIBLE FILLER AT CONNECTION WITH STRUCTURE ABOVE, UNO. 32. ALL MASONRY PARTITIONS TO RECEIVE HORIZONTAL MASONRY REINFORCEMENT AT 16" OC VERTICALLY, UNO. 33. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE 3"x3"x5/16" STEEL ANGLE POSTS WELDED TO 8"x3 1/2"x3/8" STEEL FLOOR PLATE AND 3"x3"x5/16" TOP ANGLE. PROVIDE 1" DIA HOLE IN STEEL ANGLE POSTS FOR CONDUIT. ATTACH STEEL FLOOR PLATE TO FLOOR STRUCTURE W/ (3) 3/8" DIA ANCHOR BOLTS. 34. ALL PARTIAL-HEIGHT BELOW-CEILING PARTITIONS SHALL RECEIVE GYP BD CAP & WOOD BLOCKING ATTACHED TO STEEL TOP ANGLE, UNLESS OTHER TRIM IS INDICATED. 35. ALL SHAFT WALL PARTITIONS SHALL RECEIVE J-STUD RUNNER (24 GA MIN) ATTACHED TO FLOOR STRUCTURE AND C-H MTL STUDS SPACED @ 24" OC. 36. WOOD STUD PARTITIONS SUPPORTED ON FLOORS W/ GYPSUM TOPPING SHALL HAVE DOUBLE SILL PLATES. 37. SECURE SILL PLATES ON WOOD I-JOISTS OR TRUSS-SUPPORTED FLOORS THROUGH SUBFLOOR AND INTO STRUCTURAL SUPPORT. SCHEDULE - PARTITION TYPESTANDARDS - PARTITION TYPE DESIGNATION DIAGRAMS LEGEND - PARTITION TYPE DESIGNATIONSSTANDARDS - PARTITION HEAD DETAILS STANDARDS - TYPICAL NON-LOAD-BEARING PARTITION FRAMING AND DETAILS STANDARDS - RATED WALL INTERSECTIONS STANDARDS - CONTROL JOINT DETAILS STANDARDS - ADJACENT ELECTRICAL BOXES STANDARDS - BLOCKING AND MOUNTING DIAGRAMS SEALANT 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 9 08/02/2017 01/11/18 F FG G N4 (2)F (2)FG SINGLE PANEL DOUBLE PANEL 4"6"4" 25"6"4" 4" 6" 6" 6" 6"6" 6" 12" 42" 12" X (CASED OPENING) FRAME TYPE AS SCHED. SL 6" 6"6" 6"12"SLIDING POCKET WALL DIVIDER BASIS OF DESIGN: RAYDOOR MODEL 225 (SPW) SCHEDULED PARTITION CONT. SEALANT EACH SIDE HM FRAME DOOR ASSCHEDULED2"5/8" AS SCHED.HEAD 5/8" 2"1/2"DOOR AS SCHEDULED MIN. 1/2" HM FRAME JAMB SCHEDULED PARTITION CONT. SEALANT EACH SIDE REINFORCE JAMBS PER PARTITION FRAMING DETAILS1 15/16"PARTITION + 1"REINFORCE HEAD PER PARTITION FRAMING DETAILS DOOR AS SCHEDULED HM FRAME JAMB CONT. SEALANT EACH SIDE 2" MORTAR STOP 5/8"SCHEDULED PARTITION GROUT JAMBS SOLID HEAD DOOR ASSCHEDULEDBACKER ROD SEALANT HM FRAME4"5/8"LINTEL PER STRUCTURAL 8" PRECASTEQ. EQ.SEALANT GROUT HEAD SCHEDULED PARTITION HARDWOOD MOLDING AS SPECIFIED W/ INTERIOR MOLDING TYPES HM FRAME DOOR ASSCHEDULED5/8"2"HEAD SCHEDULED PARTITION AS SCHED.HARDWOOD MOLDING AS SPECIFIED WITH INTERIOR MOLDING TYPES MIN. 1/2" HM FRAME DOOR AS SCHEDULED 5/8" 2"1 15/16"PARTITION + 1"JAMB 1/2"HEMMED BACKBEND FOR INSTALLATION OF WOOD TRIM A AS SCHEDULEDAS SCHEDULED BAS SCHEDULEDAS SCHEDULED 1'-6" D7'-0" 8"1 3/4" 1 3/4" PACKAGE WIDTH 7'-0" SCHEDULED PARTITION CONT. SEALANT EACH SIDE HM FRAME 2"CL1/2"JAMB SCHEDULED PARTITION CONT. SEALANT EACH SIDE HM FRAME REINFORCE HEAD PER PARTITION FRAMING DETAILS 2"HEAD FROSTED GLAZING, TYP. 1 POCKET GUIDEFLUSHBOLTS, OTHER SIDE, TYP. 2 3 4 SPW FOUR (4) EQUAL PANELS 13'-8" TYP 3'-7 1/4" 6" TYP. VERTICAL SIDES 10 " TYP.T.O. PANEL 8' - 0" A.F.F.FINGERPULL3' - 0" A.F.FEDGE MOUNTPANEL WIDTH +2" THREE (3) 11 7/8" LVL BEAMS SLIDING DOOR/WALL SUPPORT HEADER; SEE STRUCTURAL CONTINUOUS 2X BLOCKING 2 1/2" METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM BOARD 6" METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM BOARD 3 5/8" METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM BOARD 2 1/2" METAL STUDS @ 16" O.C. WIHT 5/8" GYPSUM BOARD PEMKO SLIDING DOOR/WALL WTH HEAD TRACK F134 FASCIA TRIM 5 1/2" 5 1/2" 1 3/4" 1/4" FROSTED TEMPERED GLASS 7 3/4" FINISHED FLOOR 1/2"9/16"5/16" 10 5/8" TRACK STOP CARRIER TRACK TOP OF LEVELED TRACK LINE OF CEILING W2 MATCH EXISTING V.I.F.MATCH EXISTINGV.I.F.MATCH EXISTING V.I.F. 5'-11 1/2"3'-11 1/2"W1 3'-8 1/2" SCHEDULED WALL BACKER ROD AND SEALANT CONT. WEATHER BARRIER WINDOW FRAMING 1" THERMAL GLAZING R.S. CEDAR TRIM; MATCH EXISTING STONE VENEER; MATCH EXISTING TYPE 'X' GYP . BD. OVER CONTINUOUS WEATHER BARRIER INTERIOR BACKER ROD AND SEALANT V.I.F.1" THERMAL GLAZING R.S. CEDAR TRIM; MATCH EXISTING TYPE 'X' GYP . BD. OVER CONTINUOUS WEATHER BARRIER INTERIOR BACKER ROD AND SEALANT CEDAR TONGUE AND GROOVE PANELING 1 A 2 3 4 5 6 A B C D E13 45 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE ORIN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTENCONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:05:36 PMDOOR & WINDOW, FRAME AND HARDWARE TYPES & SCHEDULES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A030 2211 N FRONTAGE RD, VAIL, COLORADO 81657 1. VERIFY EXISTING PARTITION THICKNESS PRIOR TO FABRICATING DOOR FRAME. 2. PROVIDE EITHER WALL STOPS OR TRACK TYPE OVERHEAD STOPS AS REQUIRED. FLOOR STOPS ARE NOT ACCEPTABLE. 3.DOORS SHOULD NOT BE UNDERCUT MORE THAN 3/4" ABOVE NEW FINISHED SURFACES. 4. DOOR FRAMES AT INSULATED PARTITIONS SHALL RECEIVE INSULATION IN JAMB. 5. ALL FRAMES & ANCHORS TO BE INSTALLED ACCORDING TO FRAME MANUFACTURER'S INSTRUCTIONS. 6. ALL HM FRAMES TO BE FULLY WELDED, UNO. 7. RATED OPENINGS SHALL RECEIVE UL RATED FRAME ASSEMBLY. 8. PROVIDE 6" MINIMUM CLEAR BETWEEN JAMB & ADJACENT PARTITION. REFER TO ACCESSIBILITY DIAGRAMS FOR CODE-REQUIRED CLEARANCES AT OPENINGS. 9. FRAMES AT EXTERIOR CONDITIONS SHALL RECEIVE INSULATION. NOTES - DOOR SCHEDULESCHEDULE - DOOR NOTES - DOOR HARDWARE DOOR NO. DOOR FRAME HARDWARE TYPE RATING COMMENTS TYPE WIDTH HEIGHT MATERIAL FINISH TYPE MATERIAL FINISH DETAIL 101A 6' - 8 1/2" 6' - 10" #4 AUTOMATIC SLIDING ENTRY DOOR 101B 6' - 8 1/2" 7' - 0"#4 AUTOMATIC SLIDING ENTRY DOOR 103A FG 2' - 93/4"6' - 11 3/4" ALUM ANOD A ALUM ANOD4A/A030 #13A 103B FG 2' - 93/4"6' - 11 3/4" ALUM ANOD A ALUM ANOD4A/A030 #13A 104B (2)F 6' - 0" 7' - 0" WD ST A HM PT 4A/A030 #6 8 PANEL STILE & RAIL CONFIG., REFER TO ELEVATION 104C 3' - 9" 7' - 0" #5 EXTERIOR STOREFRONT DOORS 104D 6' - 0"7'#7 PEMKO SIM150-5; BALLROOM SLIDING POCKET WALL DIVIDER 108 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 109A FG 3' - 1 7/16"8' - 10 1/2" ALUM ANOD A ALUM ANOD4A/A030 #17 INTERIOR STOREFRONT DOOR 109B F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #9 109E F 3' - 0" 6' - 8" (none) 109F F 3' - 0" 7' - 0" WD ST HM PT 4A/A030 #9 109L F 3' - 0" 6' - 8" (none) 111 N8 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 112 F 3' - 0" 6' - 8" WD ST A HM PT 4A/A030 #13 114 (2)F 6' - 0" 7' - 0" WD ST A HM PT 4A/A030 #5 2HR 118 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #9 119A FG 3' - 0" 7' - 10 1/2" ALUM ANOD A ALUM ANOD4A/A030 #17 INTERIOR STOREFRONT DOOR 119B X 3' - 0" 7' - 0" N/A N/A A HM PT 5B/A030 (none) N/A CASED OPENING 120 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #10 121 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #10 122 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #10 123 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #10 124 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #10 126 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #11 127 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #11 128 N4 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #11 128A F 2' - 6" 6' - 8" WD ST A HM PT 4A/A030 #9 129 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 130 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 131 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 132 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 133 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 134 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 135 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 136 N4 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #11 137 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 138 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 139 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 140 FG 3' - 0" 7' - 0" ALUM ANOD B ALUM ANOD4A/A030 #11 141 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 145 (2)F 5' - 4" 8' - 0" ALUM ANOD EXIST ANOD4A/A030 #15 147 G 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #14 148 FG 2' - 8 7/16"7' - 10 1/2" ALUM ANOD A ALUM ANOD4A/A030 #17 INTERIOR STOREFRONT DOOR 149 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 150 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #12 151A 3' - 0" 6' - 8" WD ST A HM PT 4A/A030 #18 151B 2' - 0" 7' - 0" (none) KIITCHEN MOP SINK BI-FOLD DOOR 151C 3' - 0" 7' - 0" ALUM ALUM PT 4A/A030 #19 KITCHEN DELIVERY DOOR 152 F 3' - 0" 7' - 0" WD ST A HM PT 4A/A030 #8 153 3' - 0" 7' - 0" A #14 154 F 3' - 0" 7' - 0" A HM PT 4A/A030 #15 155 (2)F 5' - 0" 6' - 8" A HM PT 4A/A030 #15 GR-A F 3' - 0" 6' - 8" A HM PT 4A/A030 #2A GUESTROOM BATH DOOR GR-BR F 2' - 8" 6' - 8" A HM PT 4A/A030 #2A CONDO UNIT BATH DOOR GR-C 3' - 0" 7' - 0" A HM #16 GUESTROOM CONNECTING DOOR GR-Da 5' - 0" 6' - 8" A HM #11 CONDO UNIT CLOSET DOOR GR-Db 6' - 0" 6' - 8" A HM #11 CONDO UNIT CLOSET DOOR GR-Dc 4' - 0" 6' - 8" A HM #11 GUESTROOM CLOSET DOOR GR-E F 3' - 0" 6' - 8" WD ST A HM PT 4A/A030 #1A GUESTROOM ENTRY DOOR GR-G 5' - 0" 6' - 8" A HM #15 GUESTROOM CLOSET DOOR - ACCESSIBLE GR-S F 2' - 4" 4' - 6" WD ST A HM PT 4A/A030 #15 CONDO UNIT UNDER STAIR STORAGE DOOR SCALE: 3" =1'-0"4A DETAIL - HM FRAME @ GYP BD SCALE:3" =1'-0"3A DTL -HM FRAME @ PRECAST SCALE:3" =1'-0"5ADTL -HM FRAME W/ WD TRIM @ GYP BD SCALE: 3" = 1'-0"2A DETAIL - CASED OPENING 1. UNLESS OTHERWISE INDICATED PROVIDE THE FOLLOWING HARDWARE FINISHES AS APPROPRIATE FOR EACH HARDWARE ITEMTHROUGHOUT THE PROJECT. A.BHMA 626/652 SATIN CHROME, BHMA 630 SATINSTAINLESSSTEEL, BHMA 689 ALUMINUM PAINTED B. BHMA 612/639 SATIN BRONZE, CLEAR COATED, BHMA 691 LIGHT BRONZE PAINTED. C. BHMA 613/640 DARK OXIDIZED SATIN BRONZE, OIL RUBBED, 609 DARK BRONZE PAINTED. 2.COMPLY WITH CURRENT REQUIREMENTS OF ADA AND ICC/ANSI A117.1. #1 GUESTROOM ENTRY DOOR (EXISTING) SOUND STRIPPING, DOOR SEAL, SECURITY LATCH, ADJUSTABLE TYPE AUTOMATIC 2-STAGE HYDRAULIC, LOW PROFILE DOOR CLOSER, DOOR VIEWER COVER, HARDWARE TO BE COMPATIBLE WITH EXISTING DOOR & FRAME #1A GUESTROOM ENTRY DOOR HINGES, SALVAGE & REUSE DOOR LOCK, SOUND STRIPPING, DOOR SEAL, SECURITY LATCH, CLOSER, DOOR VIEWER & COVER, DOOR BOTTOM #2 GUESTROOM BATHROOM DOOR (EXISTING) LEVER DOOR HANDLE, PRIVACY LOCKSET, HARDWARE TO BE COMPATIBLE WITH EXISTING DOOR AND DOOR FRAME #2A GUESTROOM BATHROOM DOOR HINGES, LEVER DOOR HANDLE, PRIVACY LOCKSET, HINGE STOP, DOOR STOP #3 GUESTROOM CLOSET DOOR PANELS, HARDWARE BY BI-FOLD DOOR MANUF. #4 AUTOMATIC SLIDING ENTRY DOOR DOOR, HARDWARE BY SLIDING DOOR MANUF. #5 EXTERIOR DOUBLE DOORS 2 PR FLOOR & OVERHEAD PIVOTS, 2 CLOSERS, 1 CYLINDER LOCK, 2 PANIC DEVICES, WEATHERSTRIPPING, THRESHOLD #6 STORAGE DOUBLE DOORS 3 PR HINGES, LOCKSET, - ACTIVE LEAF, FLUSH BOLT - INACTIVE LEAF #7 BALLROOM DOOR HARDWARE BY SLIDING POCKET WALL DOOR SYSTEM MANUFACTURER. BASIS OF DESIGN: RAY DOOR MODEL 225 WWW.RAYDOOR.COM #8 OFFICE DOOR HINGES, OFFICE LOCKSET #9 LUGGAGE ROOM DOOR HINGES, STOREROOM LOCKSET, KICK PLATE (BOTH FACES) #10 MASSAGE ROOM DOOR HINGES, PASSAGE LOCKSET #11 1ST FLOOR CORRIDOR DOOR HINGES, OFFICE LOCKSET, CLOSER, PANIC DEVICE #12 PUBLIC BATHROOM ENTRY DOOR HINGES, PUSH PLATE, PULL HANDLE, CYLINDER LOCK, CLOSER, KICK PLATE (BOTH FACES) #13 EXTERIOR SINGLE DOOR TOP & BOTTOM PIVOTS, CLOSER, ACCESS CONTROL LOCKSET, WEATHERSTRIPPING, THRESHOLD #13A EXTERIOR SINGLE DOOR TOP & BOTTOM PIVOTS, CLOSER, ACCESS CONTROL LOCKSET, WEATHERSTRIPPING, THRESHOLD, CYLINDER LOCK, PANIC DEVICE #14 GUEST LAUNDRY DOOR HINGES, CLOSER, ACCESS CONTROL LOCKSET #15 STORAGE DOOR HINGES, DUMMY LOCKSET #16 GUESTROOM CONNECTING DOOR HINGES, PASSAGE LOCKSET, LOCK GUARD, DOOR SEAL, DOOR BOTTOM #17 INTERIOR STOREFRONT DOOR PK-30 #18 KITCHEN EXIT DOOR HINGES, CLOSER, KICK PLATE, PANIC HARDWARE #19 KITCHEN DELIVERY DOOR HINGES, CLOSER, DOOR VIEWER, DOOR BELL, KICK PLATE (BOTH FACES), PUSH PLATE 7' - 0" SL ALUM ALUM ANOD ANOD ANOD ANOD 8' - 0" LEGEND - DOOR TYPES SCHEDULE - DOOR HARDWARE SCALE: 3" = 1'-0"DRAWINGREF: A6046DSLIDINGPOCKETWALLDIVIDER - HEAD DETAIL SCALE: 3" = 1'-0"5D SLIDING POCKET WALL DIVIDER - SILL DETAIL SCALE: 6" = 1'-0"6C SLIDING POCKET WALL DIVIDER - TRACK DETAIL WD SL (2) FG ALUM ANOD ANOD SPW 13' - 8" 5C/A030 108/25/2016Revision 1 310/07/2016ASI #1 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 ALUM 4A/A030 ST HM A A PT F ALUM ANOD ALUM ANOD 4A/A030 WD ST PT 4A/A030 (2)F (2)F (2)F WD WD WD ST ST ST PT PT PT 4A/A030 4A/A030 4A/A030 (2)F WD ST PT 4A/A030 LEGEND - DOOR FRAME TYPES SCALE: 6" =1'-0"2B DETAIL - WINDOW TYPE W2 HEAD AND SILL SCALE: 6" =1'-0"5BDETAIL - WINDOW TYPE W2 JAMB DETAIL Type Mark WINDOW FRAME COMMENTSWIDTH HEIGHT GLAZING TYPE MATERIAL FINISH W1 5' - 11 1/2" 3' - 11 1/2"IG LOW E II WITH ARGO ALUMINUM BRONZE W2 4' - 0" 6' - 0" MATCH EXISTING MATCH EXISTING WINDOW- ELEVATIONS SCHEDULE - WINDOW WINDOW FRAMING SCHEDULED WALL BACKER ROD AND SEALANT CONT. WEATHER BARRIER 3' - 0" 3' - 0" (2)FG ALUM ANOD ALUM ANOD 4A/A030 (2)F (2)F WD WD ST ST PT PT 4A/A030 4A/A030 MATCH EXISTING MATCH EXISTING SCALE: 3" =1'-0"3B DETAIL - WINDOW TYPE W1 SILL SCALE: 3" =1'-0"4B DETAIL - WINDOW TYPE W1 HEAD F ALUM ANOD 4A/A030 1HR 13 13 A 13 12/05/2017 01/11/18 CL EQ EQ EQ EQ EQ +/- 7'-5 1/2" 1 3/4" x 1 3/4" ALUMINUM POST 4'-0" AFF 6A A040 S5 A040 6D 10'-0"EQ EQ EQ EQEQEQ EQ EQ 9'-0"PANEL 1 EQ PANEL 2 EQ DOOR +/- 3'-3 1/2" PANEL 3 EQ PANEL 4 EQ +/- 16'-3 1/2" EQ EQ EQ EQ EQ EQ EQEQ 3'-0" MIN DOOR EQ EQ S1 1D A040 2D A040 TYP TYP EQ EQ EQ EQ EQ PANEL 1 EQ PANEL 2 EQ EQ EQ EQ EQ9'-0"S4 3'-0" MIN DOOR PANEL 2 EQ PANEL 1 EQ DOOR +/- 3'-2 3/4" +/- 9'-3 5/8"EQEQ EQ EQ 8'-0"EQ EQ EQEQ EQ EQ S3 +/- 10'-11" EQ EQ EQ EQ8'-0"EQ EQ EQEQ (2) 2'-8" MIN DOOR PANEL 1 +/- 2'-7 7/8" PANEL 2 +/- 2'-8 7/8" DOOR +/- 5'-6 1/8" EQ EQ EQEQ S2 BLOCKING IS REQUIRED FOR THIS SYTEM, BY OTHERS 1 3/4"2 5/8"3/8"1 1/2" GLASS 3/8" MIN NOTE: REF RCP FOR CEILING CONDITION BLOCKING IS REQUIRED FOR THIS SYTEM, BY OTHERS 3 7/8"1/8"1 3/4"1/4" GLASS 3/8" MIN NOTE: REF RCP FOR CEILING CONDITION EXISTING FLOOR STRUCTURE FINISH FLOOR2 5/8"1/4" 1 3/4" 1/4" GLASS DOOR SWEEP BRUSH EXISTING FLOOR STRUCTURE FINISH FLOOR 1/2" 2 5/8"1 3/4" 1/4" GLASS BLOCKING REQUIRED FOR THIS SYSTEM, BY OTHERS3/8" MIN1 1/4" 3/8"1 3/4"1/4" GLASSREF PARTITION TYPE REF PARTITION TYPENOTE: REF PLAN FOR WALL CONDITION CL1/4" GLASS1 3/4"1 1/4" 1/8" 1 1/4" CL 1 3/4" 1 3/4"1 3/4"1/4" GLASS1/8" 1 1/4" 1 3/4" x 1 3/4" ALUMINUM POST 1 3/4"1/4" GLASS3 5/8" CL CL 2 1/2" 1/4" 1" 1/8" 1 1/4"CL1/4" GLASS1 3/4"1 1/4" CONCEALED DOOR CLOSER, TRENCH EXISTING FLOOR WHERE NECESSARY FLOOR CLOSER COVER PLATEDOOR SWEEP BRUSH EXISTING FLOOR STRUCTURE 5/8" 2 5/8"1 3/4" 1/4" GLASS CL EQ EQ3/8" MINCL CL 2 7/8" 2 1/2" 3/8" 1 3/4"1/4" GLASSBLOCKING REQUIRED FOR THIS SYSTEM, BY OTHERS 1" 3/8"REF PARTITION TYPENOTE: REF PLAN FOR WALL CONDITION BLOCKING REQUIRED FOR THIS SYSTEM, BY OTHERS CL EQ EQ REF PARTITION TYPE3/8" 2 5/8"1 3/4" 1/4" GLASS NOTE: DETAIL MIRRORED VERTICALLY APPLIES TO HEADER CONDITION AT PONY WALL 9 A040 6E A040 6B A040 4E SIM REF RCP FOR CEILING CONDITION A040 5E A040 5B A040 5A A040 4E SIM REF RCP FOR CEILING CONDITION A040 5C SIM A040 5C SIM A040 4E A040 4E A040 5D SIM A040 5D SIM A040 6C SIM A040 5D SIM A040 4D A040 4E 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:30:50 PMINTERIOR STOREFRONT DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A040 2211 N FRONTAGE RD, VAIL, COLORADO 81657 INTERIOR STOREFRONT TYPES TEMPERED SCALE: 6" = 1'-0" DRAWING REF: A0406EDETAIL - FIXED PANEL TOP RAIL SCALE: 6" = 1'-0" DRAWING REF: A040 5E DETAIL -DOOR HEAD SCALE: 6" = 1'-0" DRAWING REF: A0406BDETAIL - FIXED PANEL BOTTOM RAIL SCALE: 6" = 1'-0" DRAWING REF: A0405BDETAIL -DOOR SILL SCALE: 6" = 1'-0" DRAWING REF: A040 5D DETAIL - TYPICALSTILE SCALE: 6" = 1'-0" DRAWING REF: A0404DDETAIL - TYPICAL PANEL JOIN + MULLION SCALE: 6" = 1'-0"6D DETAIL - CONNECTION AT POST SCALE: 6" = 1'-0" DRAWING REF: A0405CDETAIL - TYPICALDOOR JAMB @ PANEL SCALE: 6" = 1'-0" DRAWING REF: A040 4E DETAIL - TYPICALMULLION SCALE: 6" = 1'-0" DRAWING REF: A0405ADETAIL - DOOR SILL WITH CLOSER SCALE: 6" = 1'-0" DRAWING REF: A0406CDETAIL - TYPICALDOOR @ WALL SCALE: 6" = 1'-0" DRAWING REF: A0406ADETAIL - BOTTOM RAIL @ PONY WALL SCALE: 1" = 1'-0" DRAWING REF: A0401DSECTION - THROUGH PANEL SCALE: 1" = 1'-0" DRAWING REF: A0402DSECTION - THROUGH DOOR SCALE: 1" = 1'-0"3D TYPICAL PLAN - CENTERED DOORS SCALE: 1" = 1'-0" DRAWING REF: A4023ETYPICAL PLAN - OFFSET DOORS NOTE: COORDINATE OVERALL LENGTH OF INTERIOR STOREFRONT WITH LOCATION OF ADJACENT WALLS 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 08/02/2017 01/11/18 S7 +/- 4'-4 3/4" +/- 6 1/8" A041 4B SIM8"1'-4" 7'-6" 8'-10"SOLID PANEL ALUMINUM CORNER MULLION ALUMINUM HEADER 5B A041 A041 4C T 2" 3'-9" 2" 3'-9" 2" 5A A041 A041 3C 3E A041 1D A041 SIM S8 8'-0"8'-0"3'-0"2'-0" 3'-0"OPP A041 3C T T T T A041 1D 2" 3'-8" 2"3'-0" 2'-0" 3'-0"A041 3C 8'-0"1D A041 S9 3E A041 5A A041 OPP A041 3C T T A041 3C EIGHT (8) PANEL STILE AND RAIL WOOD DOORS 4E A041 6'-3" 1'-2"11"7'-1" SIM 6A A041 SIM 5A A041 SIM SIM, REF PLAN T A041 3D SIM ALUMINUM FRAMING WITH 1" INSULATED GLAZING 4 1/2"2"7'-1" 11"S10 4E A041 6A A041 2" SEE DOOR SCHEDULE 2" NARROW STILE DOORS T T A041 3D A041 3D OPP 3E VESTIBULE VESTIBULE101 A041 4C A041 4B A041 4D 6B A041 5B A041 A041 4B SIM WALL ABOVE WALL ABOVE (EXTERIOR) (INTERIOR) 5B A041 OPP A041 3A A041 4A SOLID PANEL BEYOND STOREFRONT BEYOND FULLY INSULATE VESTIBULE B.O. CEILING BEYOND 2"4 1/2" WRAP CORNER MULLION WITH METAL TO MATCH STOREFRONT FINISH 5/8" GYP BD 3 5/8" METAL STUDS INSULATION SEALANT SEALANT SHIM 1/4" SHIM SEALANT4 1/2" WRAP CORNER MULLION WITH METAL TO MATCH STOREFRONT FINISH SEALANT WALL BEYOND STOREFRONT 1" INSULATED GLAZING F.O. EXISTING WALL BEYOND 3 5/8" METAL STUDS ALIGN FACE OF WALL WITH EXISTING WALL BEYOND 10' - 0" 8' - 0" FINISH FLOOR FULLY INSULATE VESTIBULE ENCLOSURE A041 5A SIM A041 2D 2"4 1/2" SEALANT ALUMINUM FRAMING WITH 1" INSULATED GLAZING EXISTING 6" PRECAST CONCRETE WALL SEALANT SHIM EXISTING VESTIBULE WALL 1 3/4"4 1/2"+/- 10" (EXISTING WALL)REF EXISTINGEXISTING EXTERIOR WALL SEALANT AND BACKER ROD LOCATE DOOR IN TO-BE- DEMOLISHED DOOR'S EXISTING LOCATION FINISH FLOOR STOREFRONT FRAME BEYOND CORNER MULLION BEYOND ADA COMPLIANT THRESHOLD OPAQUE ACRYLIC PANEL ALUMINUM HEADER, MATCH STOREFRONT FINISH 1 1/2" 1 1/2"DIRECTIONAL MOTION SENSOR 8' - 0" FULLY INSULATE VESTIBULE ENCLOSURE J BEAD BACKER ROD AND SEALANT SHIM SHIM, BACKER ROD AND SEALANT 5/8" GYP BD 3 5/8" METAL STUD SHIM, BACKER ROD AND SEALANT SEALANT SEALANT 8"1'-2" DOOR MANUFACTURER STANDARD TRANSOM PANEL STOREFRONT FRAME BEYOND ALUMINUM FRAMING WITH 1" INSULATED GLAZING NARROW STILE DOOR FINISH FLOOR SET IN FULL SEALANT BED (INTERIOR) (EXTERIOR) FINISH GRADE, REF DRAWINGS, MAX 1/2" BELOW INTERIOR FINISH FLOOR 1" 2 1/4"3 7/8"STOREFRONT BEYOND BASE AS SCHEDULED, BEYOND FLASHING ADA COMPLIANT THRESHOLD ALUMINUM FRAMING WITH 1" INSULATED GLAZING NARROW STILE DOOR (INTERIOR)(EXTERIOR) STOREFRONT BEYOND 2" 4 1/2" EXPOSED AGGREGATE EXISTING 6" PRECAST PANELS BACKER ROD AND SEALANT SEALANT 2"DRIP EDGE ALUMINUM FRAMING WITH 1" INSULATED GLAZING (INTERIOR) (EXTERIOR) 4 1/2" EXPOSED AGGREGATE EXISTING 6" PRECAST PANELS BACKER ROD AND SEALANT2"SEALANT DRIP EDGE ALUMINUM FRAMING WITH 1" INSULATED GLAZING FINISH FLOOR SET IN FULL SEALANT BED (INTERIOR) (EXTERIOR) FINISH GRADE, REF DRAWINGS, MAX 1/2" BELOW INTERIOR FINISH FLOOR STOREFRONT BEYOND BASE AS SCHEDULED, BEYOND FLASHING 4"4 1/2" ALUMINUM FRAMING WITH 1" INSULATED GLAZING (INTERIOR) (EXTERIOR)4 1/2" EXPOSED AGGREGATE EXISTING 6" PRECAST PANELS BACKER ROD AND SEALANT SEALANT SHIM 8"1 1/2"2"1'-2" 2" 4 1/2" 8' - 0" AFF 3 5/8" METAL STUD 1 5/8" METAL STUD 5/8" GYP BD, ALIGN WITH EXISTING F.O. WALL BEYOND ALUMINUM HEADER, MATCH FINISH TO STOREFRONT 1 1/2"4 7/8" 1 1/2"1/2" OPAQUE ACRYLIC PANEL 4 1/2" FULLY INSULATE VESTIBULE 1 5/8" METAL STUDS 3 5/8" METAL STUDS 5/8" GYP BD ALUMINUM FRAMING WITH 1" INSULATED GLAZING SHIM, BACKER ROD AND SEALANT 5/8" GYP BD SEALANT SEALANT SHIM J BEAD BACKER ROD AND SEALANT SHIM (INTERIOR) (EXTERIOR) EXPOSED AGGREGATE EXISTING 6" PRECAST PANELS BACKER ROD AND SEALANT 4 1/2"2 1/4"2" ALUMINUM FRAMING WITH 1" INSULATED GLAZINGSEALANT SHIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:09:08 PMEXTERIOR STOREFRONT DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A041 2211 N FRONTAGE RD, VAIL, COLORADO 81657 EXTERIOR STOREFRONT TYPES TEMPERED SCALE: 3" = 1'-0" DRAWING REF: A0411DDETAIL - TYPICAL MULLION SCALE: 1" = 1'-0" DRAWING REF: A401a6DPLAN DETAIL - VESTIBULE SCALE: 1" = 1'-0" DRAWING REF: A041 6B SECTION DETAIL SCALE: 3" = 1'-0" DRAWING REF: A0414BPLAN DETAIL @ CORNER MULLION SCALE: 1" = 1'-0" DRAWING REF: A041 5B SECTION DETAIL SCALE: 3" = 1'-0" DRAWING REF: A0414CDETAIL - JAMB @ VESTIBULE SCALE: 3" = 1'-0" DRAWING REF: A0414DDETAIL - JAMB @ VESTIBULE DOOR SCALE: 3" = 1'-0" DRAWING REF:A0414ADETAIL - DOOR SILL @ SLIDING DOOR SCALE: 3" = 1'-0" DRAWING REF: A0413ADETAIL - DOOR HEAD @ SLIDING DOOR SCALE: 6" = 1'-0" DRAWING REF: A0416ADETAIL - SILL @ BALLROOM DOOR SCALE: 3" = 1'-0" DRAWING REF: A0414EDETAIL - DOOR HEAD @ TRANSOM SCALE: 3" = 1'-0" DRAWING REF: A0413EDETAIL - HEAD @ FIXED PANEL SCALE: 3" = 1'-0" DRAWING REF: A0415ADETAIL - SILL @ FIXED PANEL SCALE: 3" = 1'-0"3C DETAIL -JAMB @ FIXED PANEL NOTE: ALL EXTERIOR STOREFRONT GLAZING TO BE 1" INSULATED GLAZING UNITS SCALE: 3" = 1'-0" DRAWING REF: A0412DDETAIL - HEAD @ FIXED PANEL GENERAL NOTES 1. ALL EXTERIOR STOREFRONT GLAZING TO BE 1" INSULATED GLAZING UNITS 2. REF STOREFRONT ELEVATIONS FOR TEMPERED GLASS LOCATIONS, ALL GLAZING IN DOORS SHALL BE TEMPERED. GLAZING PANELS WITH ANY PART OF GLASS SURFACE WITHIN 18" OF FINISH FLOOR IS TO BE TEMPERED. ALL GLAZING PANELS WHRE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF THE DOOR IN A CLOSED POSITION AND THE BOTOM EDGE OF EXPOSED SURFACE IS LESS THAN 60" ABOVE FINISHED FLOOR. PROVIDE TEMPERED GLASS FOR ANY PANEL EXCEEDING 9 SF IN SURFACE AREA. SCALE: 3" = 1'-0"3D DETAIL - JAMB @ DOOR 1 08/25/2016 Revision 1 10/17/2016 01/11/18 PT SB01 EASED EDGE NOTE: POLISH ALL EXPOSED EDGES FINISH FLOOR AS SCHEDULED EASED EDGE 1/4"4"3"1/4"PAINTED PNT09 PORCELAIN TILE SCHLUTER RENO TK TRANSITION STRIP - STAINLESS STEEL CPT T-5 PORCELAIN TILE SCHULTER 'RENO-TK' EDGE STRIP CPT T-01 CPT SCHLUTER RENO U TRANSITION STRIP - STAINLESS STEEL SEALED CONCRETE T-14 T-15 CPT SCHLUTER RENO U TRANSITION STRIP - STAINLESS STEEL VCT CARPET SCHLUTER "SCHIENE" E100 S/S EDGE STRIP TILE T-16 CARPET 1/2" EDGE GUARD REDUCER STRIP CONTACT BOND ADHESIVE EXISTING CONCRETE FLOOR T-18"3/8CARPET S/S TRANSITION STRIP CARPET T-20 TILE TILE SCHLUTER "SCHIENE" EDGE STRIP SCHLUTER TREP-E STAIR EDGE TRIM TILE OR STONE SUBSTRATE T-25 T-23 PORCELAIN TILE MARBLE THRESHOLD CARPET T-02 2"5/8"9 PORCELAIN TILE EXPANSION JOINT SCHLUTER DILEX-KSBT 30 PORCELAIN TILE PORCELAIN TILE SCHULTER SYSTEMS "DECO" TRANSITION. CLEAR SATIN ANODIZED ALUMINUM CONSTRUCTION JOINT IN SLAB PORCELAIN TILE 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:30:57 PMFINISHES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A050 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 3" = 1'-0"1CDETAIL - GRANITE BASE SCALE: 3" = 1'-0"1D DETAIL - WOOD BASE LEGEND - FLOOR TRANSITION TYPES SCALE: 6" = 1'-0"2C DETAIL - PT @ EXPANSION JOINT SCALE: 6" = 1'-0"2D DETAIL - PT @ CONSTRUCTION JOINT LEGEND - INTERIOR FINISH FINISH NO. MATERIAL MANUFACTURER STYLE NAME / NO. COLOR SIZE DESCRIPTION / REMARKS ACT-001 ACOUSTICAL CEILING TILE ARMSTRONG OPTIMA TEGULAR/3355 WHITE 24" X 24" ACOUSTICAL CEILING TILE: BOH OFFICES, GM OFFICE, POOL RESTROOMS, EMPLOYEE RESTROOMS, PUBLIC RESTROOMS CG-001 CORNER GUARD INPRO CORPORATION FLEXIBLE CORNER GUARD TAUPE 0113 TOP OF BASE TO CLG x 3/4" WINGS CORRIDOR CORNER GUARDS - ADHESIVE MOUNTED CPT-100 CARPET SHAW HOSPITALITY - - - GUESTROOM CARPET - REFER TO FF&E SPECIFICATIONS CPT-300 CARPET SHAW HOSPITALITY - - - GUEST CORRIDOR CARPET - REFER TO FF&E SPECIFICATIONS CPT-600 CARPET SHAW HOSPITALITY - - - BALLROOM, MEETING ROOM & BOARDROOM CARPET - REFER TO FF&E SPECIFICATIONS CPT-900 CARPET SHAW HOSPITALITY CHOK LOOM / 5A211 KADAI / 99760 - BOH OFFICES, GM OFFICE & WORKROOM CT-001 CERAMIC TILE DALTILE CONTINENTAL SLATE / CS53 ASIAN BLACK 18" x 18" x 5/16" THICK 3/16" GROUT JOINT, MAPEI BLACK / 10 CT-002 CERAMIC TILE ARCHITECTURAL CERAMICS PENNY ROUND KILN & PENNY ARGILLA 1" ROUND BATHROOM ACCENT WALL TILE CT-003 CERAMIC TILE CERAMIC TECHNICS LTD SASSUOLO STONE VEIN WHITE NATURAL 18" x 36" LOBBY FLOOR TILE: 3/16 GROUT JOINT, MAPEI SAHARA BEIGE / 11 CT-004 CERAMIC TILE DALTILE FORMULA AXOIM SILVER / FM94 12" x 24" BOH RESTROOM FLOOR & WALL TILE, 3/16" GROUT JOINT, MAPEI OPTICOLOR CHARCOAL/ 47 CT-005 CERAMIC TILE CERAMIC TECHNICS LTD SASSUOLO STONE TEXTILES IVORY 12" x 24" PUBLIC RESTROOM FLOOR TILE CT-006 CERAMIC TILE DALTILE INVOKE / ID03 COPPER HAZE (BROWN) 12" x 24" PUBLIC RESTROOM WALL TILE, 3/16" GROUT JOINT MAPEI OPTICOLOR CHOCOLATE/ 07 CT-007 CERAMIC TILE TBD TBD TBD POOL RESTROOM FLOOR & WALL TILE CT-008 CERAMIC TILE CERAMIC TECHNICS LTD SASSUOLO STONE VEIN WHITE NATURAL 12" x 24" ELEVATOR LOBBY FLOOR TILE CTB-001 CERAMIC TILE BASE DALTILE CONTINENTAL SLATE / CS53 ASIAN BLACK 3" x 12" BULLNOSE / S-43C9 3/16" GROUT JOINT, MAPEI BLACK / 10 CTB-002 CERAMIC TILE BASE CERAMIC TECHNICS LTD SASSUOLO STONE VEIN WHITE NATURAL 6"H BULLNOSE LOBBY WALL BASE: 3/16 GROUT JOINT, MAPEI SAHARA BEIGE / 11 CTB-003 CERAMIC TILE BASE DALTILE FORMULA AXOIM SILVER / FM94 COVE - 6" x 12" BOH RESTROOM WALL BASE - INSTALL 6'6"H CTB-004 CERAMIC TILE BASE CERAMIC TECHNICS LTD SASSUOLO STONE TEXTILES IVORY COVE PUBLIC RESTROOM WALL BASE CTB-005 CERAMIC TILE BASE TBD TBD TBD COVE POOL RESTROOM WALL BASE CTB-006 CERAMIC TILE BASE CERAMIC TECHNICS LTD SASSUOLO STONE VEIN WHITE NATURAL 4"H BULLNOSE ELEVATOR LOBBY WALL BASE MTL-01 METAL PANELS AMUNEAL LIGHT BRONZE/BRASS FINISH AMU-30-UNDR-CH2ABM-C2 TBD LOBBY BACK BAR WALL PANEL -SUBMIT FINISH SAMPLE TO DESIGNER FOR APPROVAL MTL-02 METAL CLADDING AMUNEAL DARK BRONZE FINISH AMU-30-CH2C-UEG-C2 TBD REGISTRATION DESK & BAR SURFACE - SUBMIT FINISH SAMPLE TO DESIGNER FOR APPROVAL PDC-001 POWDER COAT HUNTER DOUGLAS TBD TBD - BALLROOM CEILING - SUBMIT SAMPLE TO DESIGNER FOR APPROVAL PLAM-001 PLASTIC LAMINATE ARBORITE W-465 EV MOCHA MODERN CHERRY - MILLWORK FINISH PLAM-002 PLASTIC LAMINATE - - TO MATCH DESIGNER'S SAMPLE - SAMPLE: GRAND RAPIDS CHAIR: COCOA PLAM-003 PLASTIC LAMINATE WILSONART 1500/60 GREY/MATTE FINISH - BOH CABINETS PLAM-004 PLASTIC LAMINATE WILSONART D91-60 SLATE GREY/MATTE FINISH BOH COUNTERTOPS PNT-001 PAINT SHERWIN WILLIAMS SW7636 ORIGAMI WHITE FLAT CEILING PAINT PNT-002 PAINT SHERWIN WILLIAMS PER MODEL ROOM REVIEW PER MODEL ROOM REVIEW SEMI-GLOSS GUESTROOM DOOR TRIM PAINT PNT-003 PAINT SHERWIN WILLIAMS SW7044 AMAZING GRAY KNOCKDOWN- LIGHT TEXTURE GUESTROOM WALL PAINT - 4TH FLOOR UNITS PNT-004 PAINT SHERWIN WILLIAMS TBD TBD EGGSHELL VESTIBULE & RETAIL WALL PAINT PNT-005 PAINT SHERWIN WILLIAMS SW7020 BLACK FOX SEMI-GLOSS WALL BASE PAINT PNT-006 PAINT SHERWIN WILLIAMS SW7017 DORIAN GREY EGGSHELL BOH OFFICES, GM OFFICE & WORKROOM WALL PAINT PNT-007 PAINT SHERWIN WILLIAMS TBD TBD EGGSHELL POOL RESTROOM WALL PAINT PNT-008 PAINT SHERWIN WILLIAMS SW7048 URBANE BRONZE KNOCKDOWN - LIGHT TEXTURE GUESTROOM WALL PAINT - 2ND & 3RD FLOOR SRD-001 PORCELAIN TILE STORKA LUSSO BIANCO 12"X24" SHOWER & TUB SURROUND TILE SSM-01 SOLID SURFACE MATERIAL CORIAN - ARROWROOT - BOH RESTROOM COUNTERTOP STN-001 NATURAL STONE THRESHOLD DALTILE G771 ABSOLUTE BLACK WIDTH OF DOOR FRAME GUESTROOM ENTRY DOOR STN-002 QUARTZ COUNTERTOP CAMBRIA TORQUAY - SLAB COUNTERTOP STN-003 STONE WALL TILE ARCHITECTURAL CERAMICS VTILE FIELD TILE LARGE SUTRA BLACK SPLIT FACE 4"x 15.375" FIREPLACE "STONE" WALL TILE STN-004 QUARTZ COUNTERTOP WILSONART SERENE Q1001 SLAB PUBLIC RESTROOM VANITY COUNTERTOP VB-001 VINYL BASE JOHNSONITE MANDALAY 32 PEBBLE WG 4.5"H GUESTROOM VINYL BASE VB-002 VINYL BASE JOHNSONITE MANDALAY 44 DARK BROWN 4"H BOH OFFICES, GM OFFICE & WORKROOM WALL BASE VB-003 VINYL BASE JOHNSONITE MANDALAY 29 MOONROCK 4"H BOH - STORAGE & EMPLOYEE BREAKROOM WALL BASE VB-004 VINYL BASE JOHNSONITE MANDALAY 29 MOONROCK 4"H GUEST CORRIDOR WALL BASE VCT-001 VINYL COMPOSITION TILE AMTICO STONE COLLECTION CADENCE AERIA / AROSPB31 12" x 24" BOH - STORAGE & EMPLOYEE BREAKROOM FLOOR VWC-200 VINYL WALL COVERING MDC PERLA GYPSUM - REFER TO FF&E SPECIFICATIONS VWC-300 VINYL WALL COVERING MDC ZAYNE MCO1999 - REFER TO FF&E SPECIFICATIONS VWC-301 VINYL WALL COVERING MDC FINESSE MCO2019 - REFER TO FF&E SPECIFICATIONS VWC-500 VINYL WALL COVERING MDC RIVERWOOD OYSTER - REFER TO FF&E SPECIFICATIONS VWC-600 VINYL WALL COVERING DESIGNTEX KEISHI / 6555-104 METALLIC BROWN - REFER TO FF&E SPECIFICATIONS VWC-601 VINYL WALL COVERING WOLF GORDON SKYWARD WHISPERED TAUPE - REFER TO FF&E SPECIFICATIONS VWC-602 VINYL WALL COVERING MDC BOLTA CONTRACT GILDED ONYX - REFER TO FF&E SPECIFICATIONS VWC-603 VINYL WALL COVERING MDC TUSSAH SMOKE / TFC1207 - REFER TO FF&E SPECIFICATIONS VWC-800 VINYL WALL COVERING MDC FINESSE MCO2010 - REFER TO FF&E SPECIFICATIONS VWC-801 VINYL WALL COVERING MDC RIVERWOOD MINK / TFC10574 - REFER TO FF&E SPECIFICATIONS WB-001 WOOD BASE - - PNT-005 - BALLROOM, BOARDROOM & MEETING ROOM WALL BASE WD-001 WOOD FINISH PERGO - WHITEWASHED PINE / PRARIE RIDGE OAK - GUESTROOM HEADBOARD WALL (PRARIE RIDGE OAK FOR USE IN LOFT UNITS) WD-002 WOOD FINISH - - TO MATCH DESIGNER'S SAMPLE - SAMPLE: GRAND RAPIDS CHAIR: DRIFTWOOD WD-003 WOOD FINISH - - TO MATCH DESIGNER'S SAMPLE - SAMPLE: GRAND RAPIDS CHAIR: COCOA WD-004 WOOD PANEL KD PANELS - DYED OAK / K6309 - LOBBY WALL FINISH WD-005 WOOD FINISH RESAWN TIMBER ENCORE COLLECTION BLACK & TAN - REGISTRATION DESK FEATURE WALL TA-1 18" GRAB BAR, WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL, INSTALL VERTICALLY TA-2 42" GRAB BAR, WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL TA-3 36" GRAB BAR, WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL TA-4 SEAT COVER DISPENSER, BOBRICK B-3013 TRIM-LINE SERIES RECESSED SEAT COVER DISPENSER TA-5 WALL MOUNTED SOAP DISPENSER, BOBRICK B-2012 AUTOMATIC WALL-MOUNTED SOAP DISPENSER TA-6 18" GRAB BAR, WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL TA-7 DOUBLE ROBE HOOK, WINGITS, MODERN ELEGANCE / WMEDRH, POLISHED STAINLESS STEEL TA-8 WALL BUMP TA-9 PAPER TOWEL DISPENSER, BOBRICK B-29744, SEMI RECESSED AUTOMATIC, UNIVERSAL ROLL PAPER TOWEL DISPENSER TA-10 COMBINATION PAPER TOWEL DISPENSER, BOBRICK B-3974 RECESSED AUTOMATIC UNIVERSAL ROLL PAPER TOWEL DISPENSER AND WASTE RECEPTACLE TA-11 SANITARY NAPKIN DISPOSAL UNIT, BOBRICK B-35303, RECESSED SANITARY NAPKIN DISPOSAL TA-12 BABY CHANGING STATION, BOBRICK KB110-SSRE. HORIZONTAL, RECESSED MOUNTED BABY CHANGING STATION TA-13 TOILET TISSUE DISPENSER, MODERN ELEGANCE / WMEHVTPH, INSTALLED HORIZONTALLY TA-14 VENDOR TA-15 DYSON, AIRBLADE V, LOW VOLTAGE, NICKEL TA-16 24" GRAB BAR,WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL, INSTALL VERTICALLY ON BACK WALL TA-17 24" GRAB BAR, WINGITS, MODERN ELEGANCE / WGB5ME, POLISHED STAINLESS STEEL TA-18 18" TOWEL BAR, WINGITS, MODERN ELEGANCE / WMETBPS18, POLISHED STAINLESS STEEL TA-19 CURVED SHOWER ROD, WINGITS, CONTOUR OVAL 5 FT. S/S CURVED SHOWER ROD / WOCON5, POLISHED STAINLESS STEEL TA-20 DUAL BYPASS SHOWER DOOR, BELSTONE, URBANITE BYPASS DOOR, POLISHED STAINLESS STEEL, 3/8" THICK TEMPERED SAFETY GLASS TA-21 CORNER SOAP DISH, WINGITS, CONTOUR 8" CORNER BASKET / WCONCBxx8, POLISHED STAINLESS STEEL, INSTALL 48" AFF ON CORNER OF SHOWERHEAD WALL TA-22 FOOTREST, WINGITS, TUBULAR CORNER FOOT REST / WFRTC, POLISHED STAINLESS STEEL, INSTALL 15" AFF ON BACK WALL CORNER OPPOSITE SHOWERHEAD WALL TA-23 DOUBLE TOILET PAPER HOLDER, WINGITS, MODERN ELEGANCE / WMEDHTPH, POLISHED STAINLESS STEEL TA-24 12" TOWEL BAR, WINGITS, MODERN ELEGANCE / WMETBPS12, POLISHED STAINLESS STEEL TA-25 24" TOWEL BAR, WINGITS, MODERN ELEGANCE / WMETBPS24, POLISHED STIANLESS STEEL TA-26 ADA SHOWER SEAT, WINGITS PURE ELEGANCE / PUEX28LHWH, GLOSSY WHITE TA-27 ADA TUB SEAT, WINGITS PURE ELEGANCE / WHPTB265150, PHENOLIC WHITE LEGEND - TOILET ACCESSORIES 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 SITE PLAN PROVIDED AS PART OF EXTERIOR BUILDING SUBMISSION, # B16-0254 E16-0135 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:09:23 PMSITE - PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A101 2211 N FRONTAGE RD, VAIL, COLORADO 81657 10/17/2016 01/11/18 DN DN DN REF oc oc ocococFSBSB SB SB JDDDDkpkp DD D DD v v vvv voc oc oc ocococ3ocJocJ FCMF F FFV VF FVT T TTT T Mkpoc oc ockpocF V J FFJ MJM FJ ocCRDL DLCR33J J J F F J Ref. Under Counter OFFICE 4 129 POOL SPA FITNESS CENTER 148 STAIR SKI & BOOT STORAGE 111 WORK AREA 108 LUGGAGE ROOM 118 FIREPLACE 4'-1" 4'-1" 4'-1" 0'-0" TRANS. A404 2A A403 3A A404 4A A405 3A A406 2A A410 4A ELECTRICAL 116 ROOM 120 ROOM 121ROOM 122 ROOM 123 ROOM 124 MASSAGE/ SPA WAITING 119 BOARDROOM 126MEETING ROOM 127 MECHANICAL 146 POOL EQUIP 145 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101SKI BOOT REMOVAL AREA 110 OFFICE 3 130 OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 BALLROOM/ MEETING ROOM 104 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 134 108 118 140 A401a 4A ALIGNALIGN ALIGNALIGNCORRIDOR 119B 1'-9" 4'-1"0'-0" A401b 4A PREFUNCTION 152 9.13 9.13 RAMP UP RAMP UP MEETING STORAGE 153 6'-8" 6'-8" W EMPLOYEE LOCKER ROOM 137 A406 5A A410 2A A402 2A 5E A111 0'-0"1'-9" 4'-1" 21.1 A605 2A 133 A602 S7 S7 OFFICE 2 131 CLOSET ALIGN ALIGN 4" 1'-6" UP A6a 104D 101A 101B 111 104C 104B 109A 149 150 119A 120 119B 121 122 123 124 126 127 129 131132 130 128A 128 135 137 138 139 141 145 S5 S4 S9 S8 S10 S1 S2 148 147 S3 VEND VEND 136 4E SK-1 1 KITCHEN STORAGE 142 152 60" CLEAR MINALIGN A404 6E 5E DISHWASHING 106 151A 153 103B 114 112 103A 154 155 109F RETAIL 109 A0304 A030 5 5C 13 MAIN FLOOR 100' - 0" 02_MAIN FLOOR 101' - 9" 03_MAIN FLOOR 104' - 1" DOOR TO OFFICE DOOR TO MEETING ROOM DOOR TO BOARD ROOM 9'-3"9'-9"7'-10"8'-0"9'-9"8'-0"7'-6"3'-0"A121 2E A121 5E A121 6E 4E A121 6"3'-0"7'-6"GYP BD SOFFIT HANDRAIL BRACKETS @ 4'-0" O.C. TYP. 01_MAIN FLOOR 100' - 0" 02_SECOND FLOOR -1 112' - 0" 2ND FLOOR - REFLECTED CEILING PLAN 114' - 2" 03_MAIN FLOOR 104' - 1" 6E A111 1 1/2" DIA WOOD HANDRAIL 3'-0" T.O. RAILINGCL 2 1/2"3/4" 2'-7 1/4" 1 1/2" DIA EXTRUDED ALUMINUM, PART OF POST ASSEMBLY 1/2" DIA EXTRUDED ALUMINUM, PART OF POST ASSEMBLY METAL HANDRAIL TO POST ATTACHMENT REF PLAN 3" DIA ALUMINUM POST BASE 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:05:58 PMOVERALL PLAN - 1ST FLOOR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A111 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 9.135/8" GYP BOARD OVER EXISTING STUDS. FILL CAVITY W/ THERMAL INSULATION (R-13). 21.1 PAINT FIRE EXTINGUISHER CABINET TO MATCH NEW ADJACENT WALL FINISH COLOR. SCALE:1/8" = 1'-0"DRAWING REF: A1116AOVERALL PLAN -FIRST FLOOR SCALE: 1/4" = 1'-0" DRAWING REF: A1115ESECTION - RAMP SCALE: 1" = 1'-0" DRAWING REF: A111 6E DETAIL - HANDRAILAND POST 108/25/2016Revision 1 310/07/2016ASI #1 7 3/28/2017RFI 71 Response 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 12/05/2017 01/11/18 DN UP A430 3A A441 3A A442 3A K1L 208 QQ1L 205 KAL 204 KS 201 K1L 228 K1L 238 K1R 236 K1R 234 K1L 232 K1R 230 K1R 226 K1L 224 K1R 222 K1L 220 K1R 218 K1L 216 K1R 214 K1L 212 K1R 210 KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 K3 206 KAR 203 K2 202 LAUNDRY 200 A431 3A A449 3A A432 3A A434 3A CORRIDOR 240 2A3A5A A450 4A (FORMER GUEST LAUNDRY) A114 6A 3 A443 3A KS 301 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 K1L 316 K1R 314 K1L 312 K1R 310 K1L 308 QA 306 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 HOUSEKEEPING 300 CORRIDOR 340 A435 3A A114 6A 3 A112 3E 12.1 9.8 9.1 9.4 9.926.12T CG-001 3 SEE ENLARGED GUESTROOM PLANS FOR DOOR TYPE/HARDWARE SET 3 3 3 B VB-004 W VWC-300 8'-1"7'-4"T.O. CEILING AT COVE MAIN CORRIDOR CEILING DOOR ALCOVE BEYOND, TYP, REF PLANS 3 3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:09:53 PMOVERALL PLAN - 2ND & 3RD FLOORS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A112 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 9.1 INSTALL CARPET AND PADDING. 9.4 PROVIDE VWC. 9.8 PROVIDE MILLWORK PROFILE VINYL BASE. REFER TO FINISH LEGEND ON A050 FOR DETAILS. 9.9 PROVIDE FULL HEIGHT CORNER GUARDS. OPAQUE COLOR TO MATCH VWC AND ADHESIVE MOUNTED. 12.1 INSULATE PIPES. 26.12 REFER TO ELECTRICAL SHEETS FOR CORRIDOR LIGHTING SCOPE. SCALE: 1/8" = 1'-0"6A OVERALL PLAN - 2ND FLOOR SCALE: 1/8" = 1'-0"6D OVERALL PLAN - 3RD FLOOR SCALE: 1/4" = 1'-0" DRAWING REF: MR-A4012EPLAN - TYP CORRIDOR SCALE: 1/4" = 1'-0" DRAWING REF: 13EELEVATION - TYP CORRIDOR 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 3 3 10/17/2016 01/11/18 DW DN UP UP UP DWREF.DWREF. REF DWREF. DN DN DN HOUSEKEEPING 400 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412 Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434 DKL 436 Q1 438 KEXR 439 DKR 437 K4L 435 KKCON 433 K4L 431 KKCON 429 K4L 427 KKCON 425 K4L 423 KKCON 421 K4L 419 KKCON 417 K4L 415 KKCON 413 K4L 411 KKCON 409 K4L 407 KKCON 405 K4L 404 KCONR 403 KEXL 402 A448a 3A A447 3A A444 3A CORRIDOR 440 A436 3A A446a 3A2A3A4A A445a 5A A114 6C A437a 3A SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM SIM A451a 3A 3A4A A452 5A 3A4A A453 5A 3E A123 58'-8"CL27'-8 3/4"5'-4 1/4"CL13'-8 3/4" 3 1/2" 2'-6 1/2" 10'-3 1/2"13'-9 3/4" 10'-2 3/4" 11'-5 1/2" 11'-5 1/2" DKR+ 537 DKL+ 536 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 OPEN TO HOUSEKEEPING ELEVATOR SHAFT A448b 5B A446b 3A OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW 2A3A4A A445b 5A A437b 3A A451b 4A 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:31:26 PMOVERALL PLAN - 4TH FLOOR & LOFT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A113 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: A5006AOVERALL PLAN - 4TH FLOOR KEYNOTES SCALE: 1/8" = 1'-0" DRAWING REF: A5016DOVERALL PLAN - 4TH FLOOR UPPER LEVEL/LOFT 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 5 tbd ASI #4 9 7/21/2017 CCD-005 9 08/02/2017 01/11/18 DW REFDWREF. DWREF. REF DWREF. CORRIDOR 340 A114 6B C PNT-001 W VWC-300 B VB-004 F CPT-300 W VWC-301 TYP DOOR DROPS. C PNT-001 W VWC-300 B VB-004 F CT-008 3 W VWC-301 W VWC-301 ..3 9.239.23 T-01 T-01 CSG-3003 3 A114 2E 3 MIR-300ART-300ART-301 ART-302 ART-303 3 3 3 3 T.O. CEILNG AT COVE MAIN CORRIDOR CEILING DOOR ALCOVE BEYOND, TYP, REF PLANS 8'-1"7'-4"5'-3" CLEQ EQ 3 CLEQ EQ 5'-3" 3 A114 6D CORRIDOR 440 C PNT-001 W VWC-300 B VB-004 F CPT-300 W VWC-301 TYP DOOR DROPS. C PNT-001 W VWC-300 B VB-004 F CT-008 3 W VWC-301 W VWC-301 . .3 A114 2E T-01 T-01 CSG-300 3 3 3 MIR-300 9.23 9.23ART-300ART-301 ART-302 ART-303 3 3 3 3 A451a 6B 4B T.O. CEILNG AT COVE MAIN CORRIDOR CEILING DOOR ALCOVE BEYOND, TYP, REF PLANS 8'-1"6'-10"6'-10"8'-1"7'-4"5'-3"CL EQEQ 33 5'-3"CL EQ EQ 5'-0"CLEQ EQ CLCL CL 1'-6" 1'-6" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:10:23 PMTYPICAL CORRIDOR PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A114 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: A1126ACORRIDOR PLAN - 2ND AND 3RD FLOORS SCALE: 1/8" = 1'-0" DRAWING REF: A1126BCORRIDOR ELEVATION - 2ND AND 3RD FLOORS SCALE: 1/8" = 1'-0" DRAWING REF: A1136CCORRIDOR PLAN - 4TH FLOOR SCALE: 1/8" = 1'-0" DRAWING REF: A1146DCORRIDOR ELEVATION - 4TH FLOOR 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 SCALE: 1/4" = 1'-0" DRAWING REF: A0102EELEVATION - ELEVATOR LOBBY KEYNOTES 9.23 PROVIDE CONTINUOUS TRANSITION STRIP AT CHANGE OF FLOOR FINISHES. 3 10/17/2016 01/11/18 MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 A402 4A ROOM 124 ROOM 121 ROOM 122 ROOM 123 ROOM 120 CORRIDOR 119B A403 5A ENGINEER 133 OFFICE 3 130 OFFICE 1 132 OFFICE 4 129 RECEPTION 128 ELECTRICAL 116 LUGGAGE ROOM 118 TELECOM ROOM 117 ROOM 115 ELEVATOR EQUIP 113 EXIT PASSAGE 114 SKI & BOOT STORAGE 111 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 CHECK-IN 107 WORK AREA 108 DISHWASHING 106 MADE MARKET 105 WOMEN'S 150 MEN'S 149 GUEST LAUNDRY 147 FITNESS CENTER 148 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 M EMPLOYEE LOCKER ROOM 138 EMPLOYEE BREAK ROOM 136 STORAGE 135 ENGINEER STORAGE 134 NOT IN SCOPE CORRIDOR 140 BALLROOM/ MEETING ROOM 104 A404 4B A404 2B A406 3A A405 5A A401c 4A A406 5B A410 5A A410 3AC GYP 9' - 9" A.F.F. C GYP 7' - 10" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. W EMPLOYEE LOCKER ROOM 137 C GYP 8' - 0" A.F.F. C GYP 9' - 0" A.F.F. MASSAGE/ SPA WAITING 119 C GYP 8' - 0" A.F.F. C GYP 7' - 10" A.F.F. C NEW 14' - 6 15/32" A.F.F. C EXISTING SLOPED C GYP 9' - 3" A.F.F. C GYP 11' - 7 3/4" A.F.F. C EXIST 8' - 0" A.F.F. C GYP 8' - 0" A.F.F. C GYP 10' - 0" A.F.F. C GYP 9' - 0" A.F.F. 9.21 9.21 9.21 6'-8" 6'-0" 6'-0" 6'-0" 6'-0" 3'-0"CL6'-0"6'-0" 2'-0" C ACT 8' - 0" A.F.F. OFFICE 2 131 C GYP 7' - 6" A.F.F. KITCHEN STORAGE 142 C NEW 13' - 2" A.F.F. C NEW 13' - 2" A.F.F. C GYP 10' - 0" A.F.F. C EXPOSED SLOPED KITCHEN 151 C GYP 9' - 0" A.F.F. C GYP 9' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. 13 1'-5 1/2"6'-0" 5'-9" 5'-9" 2'-5 3/4" 5'-4 1/2"7'-10 3/4" 4'-0" EQ. EQ.6"CL1'-11" 4 7/8" 8'-0" 7'-10" 9'-9" 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. SUSPENDED CEILING 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" BRACING @ 4'-0" O.C. 9'-9" 9'-3" 3 5/8" BRACING @ 4'-0" O.C. 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. RECESSED CAN LIGHT EDGE OF WALL, BEYOND 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. 4 7/8" 9'-3" 9'-9" 12'-1"8'-0" TOLANDING5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16". O.C. 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. 2 1/4" 12'-1" 5/8" GYP BD ON 1 5/8" METAL STUDS @ 16" O.C. EXISTING PRE-CAST WALL 5/8" GYP BD ON 3 5/8" METAL STUDS @ 16" O.C. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:06:12 PMREFLECTED CEILING PLAN - 1ST FLOOR PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A121 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 9.21 NO FINISHED CEILING, THIS SPACE. SCALE: 1/8" =1'-0"DRAWING REF: A1116A1STFLOOR -REFLECTED CEILING PLAN SCALE: 1 1/2" = 1'-0" DRAWING REF: A1112ECEILINGDETAIL SCALE:1 1/2" = 1'-0"DRAWING REF: A111 4E CEILING DETAIL SCALE: 1 1/2" = 1'-0"DRAWING REF: A111 5E CEILING DETAIL SCALE:1 1/2" = 1'-0"DRAWING REF: A111 6E CEILING DETAIL C PNT-001 C PNT-001C PNT-001 C PNT-001 C PNT-001 C PNT-001 C PNT-001 C PNT-001 108/25/2016Revision 1 6 3/27/2017RFI 73R1 Response 7 3/28/2017RFI 71 Response 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 12/05/2017 01/11/18 KSR 201 K1L 208 QQ1L 205 K1L 228 KAL 204 K1R 238 K1L 236 K1R 234 K1L 232 K1R 230 K1R 226 K1L 224 K1R 222 K1L 220 K1R 218 K1L 216 K1R 214 K1L 212 K1R 210 KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 K3 206 KAR 203 K2 202 LAUNDRY 200 A441 6A A442 6A A432 6A A434 6A A430 6A CORRIDOR 240 C GYP 6' - 10" A.F.F. C GYP 6' - 8" A.F.F. A431 6A A449 6A A450 6A A122 2E C GYP 7' - 4" A.F.F. CLEQ 4'-3" EQ EQ EQEQ EQCLEQ 6'-6" 6'-6" EQ C EXISTC EXIST 8' - 1" A.F.F.8' - 1" A.F.F. C PNT-001 C PNT-001 C PNT-001 C PNT-001 C PNT-001 4E A122 SIM HOUSEKEEPING 300 KSR 301 QA 306K1L 308 K1R 310 K1L 312 K1R 314 K1L 316 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 CORRIDOR 340 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 C GYP 6' - 10" A.F.F. A435 6A A443 6A C GYP 6' - 8" A.F.F.CLEQ EQEQEQ C GYP 7' - 4" A.F.F.EQEQ EQ 4'-3" EQ CLCL6'-6" 6'-6" C EXIST 8' - 1" A.F.F. 6E A122 C PNT-001 C PNT-001 C PNT-001 C PNT-001 4E A122 10" C GYP 6' - 10" A.F.F.C GYP 7' - 4" A.F.F.1'-0"4'-0" 1'-0" C EXIST 8' - 1" A.F.F. PIPE ETR LED STRIP LIGHTING 9"AS REQUIRED LED STRIP LIGHTING SOFFIT 6' - 10" FINISH FLOOR ABOVE 8' - 10" 5"5" 7' - 4" AFF FINISH FLOOR ABOVE 8' - 10" EXISTING CEILING EXISTING FRAMING TO REMAIN 5/8" GYPSUM BOARD 1/4" GYPSUM BOARD SCREW TO CLIP ANGLE 1/4" PLYWOOD REMOVABLE PANEL, 8' LENGTH MAX., PAINT SCREW TO EXIST. FRAMING SEALANT CONT. CLIP ANGLE EXISTING BUS DUCT V.I.F.V.I.F.1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:31:52 PMREFLECTED CEILING PLAN - 2ND & 3RD FLOORS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A122 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES SCALE: 1/8" = 1'-0"6A2ND FLOOR SCALE: 1/8" = 1'-0"6D 3RD FLOOR - REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" DRAWING REF: A1222EENLARGED RCP - TYPICAL DOOR DROP SCALE: 1" = 1'-0" DRAWING REF: A1226ESECTION DETAIL - TYPICAL CORRIDOR CEILING @ PIPE 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 9 SCALE: 1" = 1'-0" DRAWING REF: A1124ESECTION - TYP. CORRIDOR CEILING LEVEL 2 & 3 08/02/2017 01/11/18 DKR+ 537 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 DKL+ 536 A445b 6A A446b 6A A448b 4D A451b 4C 6' C GYP 6' - 10" A.F.F. C GYP 6' - 10" A.F.F. A436 6A A437a 6A HOUSEKEEPING 400 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412 Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434 DKL 436 Q1 438 KEXR 439 DKR 437 K4L 435 KKCON 433 K4L 431 KKCON 429 K4L 427 KKCON 425 K4L 423 KKCON 421 K4L 419 KKCON 417 K4L 415 KKCON 413 K4L 411 KKCON 409 K4L 407 KKCON 405 K4L 404 KCONR 403 KEXL 402 CORRIDOR 440 A444 6A A447 6A A446a 6A A448a 6A C GYP 7' - 4" A.F.F. CLEQ 4'-3" EQCL EQ EQCLEQ EQCLCL CL EQ 6'-6" 6'-6" EQ C EXIST 8' - 1" A.F.F. C EXIST 8' - 1" A.F.F. C PNT-001 C PNT-001 C PNT-001 C PNT-001 C PNT-001 A445a 6A A452 6A A453 6A 3E A123 SIM FINISH FLOOR ABOVE 8' - 10" EXISTING CEILING 1 5/8" METAL STUD FRAMING PROVIDE FINGER CLEARANCE FOR BUS DUCT ACCESS 5/8" GYPSUM BOARD 1/4" GYPSUM BOARD SCREW TO CLIP ANGLE 1/4" PLYWOOD REMOVABLE PANEL, 8' LENGTH MAX., PAINT SCREW TO EXIST. FRAMING SEALANT CONT. CLIP ANGLE EXISTING BUS DUCT V.I.F.1 5/8" V.I.F. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:32:01 PMREFLECTED CEILING PLAN - 4TH FLOOR UPPER LEVEL/LOFT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A123 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES SCALE: 1/8" = 1'-0" DRAWING REF: A5016D4TH FLOOR UPPER LEVEL/LOFT - REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" DRAWING REF: A5006A4TH FLOOR - REFLECTED CEILING PLAN 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 9 9 SCALE: 1" = 1'-0" DRAWING REF: A1123ESECTION - TYP. CORRIDOR CEILING LEVEL4 9 08/02/2017 01/11/18 DN DN REF Ref. Under Counter POOL SPA STAIR SKI & BOOT STORAGE 111 COVERED DROP OFF MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 RETAIL 109 OFFICE 3 130 OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 F CPT-600 B WB-001 W VWC-600 W EMPLOYEE LOCKER ROOM 137 W VWC-603 C PNT-001 W WD-002 T-16 F CT-003 B CTB-002 W VWC-602 C PNT-001 PNT-006 PNT-006 F CT-003 B CTB-002 W VWC-500 C PNT-001 F CT-003 B CTB-002 W WD-004 C WD-004 F CPT-600 B WB-001 W VWC-601 C PNT-001 F CPT-600 B WB-001 W VWC-601 C PNT-001 W WD-004 ABOVE BAR F CT-003 B CTB-002 W WD-004 W WD-004 W STN-003 W STN-003 W WD-004 F CT-003 B CTB-002 C WD-004 W WD-004 F CT-003 B CTB-002 C PNT-001 W VWC-602 F CT-003 B CTB-002 C PNT-001 W WD-005 C PNT-001 F CT-003 B CTB-002 W VWC-603 C ACT-001 W VWC-603 C ACT-001 F CT-003 B CTB-002 F CT-003 B CTB-002 F CT-003 B CTB-002 C ACT-001 W PNT-008 F CT-004 B CTB-003 C ACT-001 W PNT-008 F CT-004 B CTB-003 W PNT-004 W PNT-004 W PNT-006 C ACT-001 F CPT-900 B VB-002 W VWC-800 C PNT-001 F CT-005 B CTB-004 W CT-006 W CT-006 C ACT-001 W PNT-007 F CT-007 B CTB-005 W CT-007 W CT-007 W CT-004 W CT-004 W PNT-006 C ACT-001 F CPT-900 B VB-002 W PNT-006 C ACT-001 W PNT-006 W PNT-006 W PNT-006 C ACT-001 F VCT-001 B VB-003 W PNT-006 C ACT-001 F VCT-001 B VB-003 W WD-004 W WD-004 W VWC-603 C PNT-001 F CT-003 B CTB-002 9 KITCHEN STORAGE 142 9 9 9 9 9 9 9 ATM 9 9 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:32:10 PM1ST FLOOR - FINISH PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A131 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES SCALE: 1/8" = 1'-0" DRAWING REF: A1116AFINISH PLAN - FIRST FLOOR 1 08/25/2016 Revision 1 6 3/27/2017 RFI 73R1 Response 7 3/28/2017 RFI 71 Response 9 7/21/2017 CCD-005 08/02/2017 01/11/18 DN DN DN REF Ref. Under Counter POOL SPA EXIT PASSAGE ELEVATOR EQUIPMENT EXIT PASSAGE STAIR SKI & BOOT STORAGE 111 VEST. COVERED DROP OFF ENGINEER ENGINEER STORAGE STORAGE EMPLOYEE BREAK RM. BOH OFFICES MASSAGE POOL EQUIP. MECHANICAL BOARDROOMMEETING ROOM LUGGAGE ROOM ELECTRICAL FITNESS CENTER KITCHEN WORK AREA GM OFFICE BALLROOM RETAIL SPACE CHECK IN LOBBY BAR MADE MARKET SKI & BOOT REMOVAL EMPLOYEE RESTROOM EMPLOYEE RESTROOM POOL RESTROOM POOL RESTROOM GUEST LAUNDRY PUBLIC RESTROOMS A401b 4A LOUNGE LTG-600 QTY. 4 CSG-600 UPH-600 QTY.12 UPH-701 QTY.10 QTY. 5 CSG-701 UPH-702 QTY.8 QTY.2 UPH-701 QTY. 8 CSG-701 UPH-702 UPH-702 CSG-701 QTY. 4 UPH-700 QTY. 3 QTY. 2 CSG-703 UPH-700 QTY. 4 CSG-705 UPH-700 QTY. 4 CSG-705 ACC-700 ACC-700 ACC-700 QTY. 2 PROJECTOR SCREEN PROJECTOR SCREEN 60" FLAT SCREEN TV EQU-600 42" FLAT SCREEN TVEQU-900 REFER TO HILTON APPROVED PLAN FROM LIFE FITNESS FOR EQUIPMENT SPECIFICATIONS AND DETAILS VEND VEND 45'-1"UPH-706 QTY.7 UPH-705 QTY.7 UPH-703 UPH-703 UPH-704A UPH-704C UPH-704B CSG-702 QTY.4 UPH-707 QTY.2 UPH-709 CSG-706 QTY.3 UPH-709 CSG-706 QTY.3 UPH-709 CSG-706 QTY.3 UPH-709 CSG-706 CSG-704 QTY. 2 QTY. 2 QTY. 2 CSG-704 CSG-700 QTY. 4 CSG-700 CSG-700 CSG-704 QTY.16 QTY.4 QTY.3 ACC-701 ACC-701 ACC-701 ACC-701 9 KITCHEN STORAGE 9 9 9 9 ATM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:32:21 PM1ST FLOOR - FF&E PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A141 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: A1116AOVERALL PLAN - FIRST FLOOR FF&E 1 08/25/2016 Revision 1 7 3/28/2017 RFI 71 Response 9 7/21/2017 CCD-005 9 9 9 08/02/2017 01/11/18 10/06/2017 01/11/18 A401d 6B VESTIBULE 101SKI BOOT REMOVAL AREA 110 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 3B3A 6A A401d 4D 6D 3E5E 111 F3a A4a A4a F2a 13'-2" 16'-5 3/4" S7 S7 A041 6D F2a F2a ALIGN, COORDINATEWITH MILLWORK7'-1" 35'-3" A502 5A A606 3A A041 6 A602 S1 S5 F2aF2a W1a A4a A401a 6B A401a 6A A4b A4a W1a W1a ABOVE 101A 101B 109A 108 A401a 6E A401 3E A401a 6E A401a 5E A401a 5E A4a A4a A4a A4a F2a F2a EXIT PATH 'P1' 17'-8 3/4" 8'-1 3/8"1 3/4" 3'-6" 33'-3 13/16" 34'-7 1/4"4'-10 1/4" SKI & BOOT STORAGE 111 EXIT PASSAGE 114 RETAIL 109 VESTIBULE 143 A6a A6a A6a A6a 9'-6"5'-6"103A 103B 7'-1" 9'-4 1/2"10'-3" 32'-5 9/16" 7'-0 1/8"6" 3'-11" 11'-5 3/4"8'-2" B6E 112 109F 114 W2 A0304 A030 5 4'-6 1/4"EQ EQA504 6A 6'-4" A5041E A504 2E A504 5E A504 6E A504 4E A041 6 Sim A4a A4a 6'-0 1/4"2'-8 7/16" 18'-1 5/16" 6'-11 3/16" A4a 3'-0 7/8" 7'-7 7/16" 3'-1" 8'-4 1/2"2'-4" 3'-5 3/8"CL 4'-11 7/16" A4a 5'-4 7/8"8'-3 1/4" 151A KITCHEN 151 MADE MARKET 105 DISHWASHING 106 WORK AREA 108 CHECK-IN 107 EXIT PASSAGE 112 151B 5C 13 151C HORIZONTAL WOOD FURRING VERTICAL TONGUE AND GROOVE PLANKS VERTICAL TONGUE AND GROOVE PLANKS VERTICAL TONGUE AND GROOVE PLANKS HORIZONTAL WOOD FURRING EXISTING STRUCTURAL CONCRETE WALL W1a W1a A4a F2a HORIZONTAL WOOD FURRING VERTICAL TONGUE AND GROOVE CHARRED WOOD PLANKS 3/4" PLYWOOD 3 5/8" METAL STUDS 3/4"x3/4" ALUMINUM REVEAL, XTREME TRIM OUTSIDE CORNER REVEAL X0CR34M, OR EQUIVALENT, MITER JOINTS WHERE VERTICAL AND HORIZONTAL REVEALS MEET COUNTER BELOW VERTICAL METAL FURRING W1aF2a F2a A4b SHIM OUT GYP BD AS NECESSARY 1" 1" PLANKING JAMB PIECE PLANKING 1" PLANKING BEYOND 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:06:25 PMENLARGED FLOOR PLAN - LOBBY/LOUNGE/BAR/KITCHEN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A401a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE:1/4" = 1'-0"DRAWING REF: A1114AENLARGEDFLOORPLAN - LOBBY/LOUNGE/BAR SCALE: 1 1/2" =1'-0"DRAWING REF:A401a6BPLANDETAIL - WOOD AT CORRIDOR SCALE: 1 1/2" =1'-0"DRAWING REF:A401a6APLANDETAIL - WOOD AT INSIDE CORNER 108/25/2016Revision 1 6 3/27/2017RFI 73R1 Response 7 3/28/2017RFI 71 Response 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 SCALE: 3" =1'-0"6E DETAIL - PLANKING AT DOOR JAMB AND HEAD SCALE: 1 1/2" = 1'-0"6C DETAIL - PLANKING AT WINDOW JAMB AND HEAD SCALE: 1 1/2" =1'-0"6D DETAIL -PLANKING AT WINDOW SILL 12/05/2017 01/11/18 351 SF RETAIL 109 SKI BOOT REMOVAL AREA 110 VESTIBULE 101 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 UPH-401 CSG-400 CSG-400 UPH-400 UPH-400 QTY. 3 QTY. 3 UPH-402 QTY.2 QTY. 4 QTY. 2 UPH-403 CSG-401 UPH-404QTY. 4 UPH-402 QTY. 2 LTG-400 LTG-400 CSG-403 CSG-404 UPH-405 UPH-406 CSG-405 CSG-406 QTY. 6 UPH-407 UPH-407 QTY. 3 QTY. 3 UPH-411 LTG-400 LTG-400 QTY. 2 QTY. 2 CSG-403 UPH-400 QTY. 2 QTY. 6 UPH-409 QTY. 6UPH-409 QTY. 6 QTY. 4 CSG-403 QTY. 2 CSG-408CSG-408 EQU-400 EQU-401 QTY. 3 UPH-413 UPH-412 UPH-412 UPH-413 CSG-410 CSG-410 CPT-401 CPT-401 CSG-409 UPH-414 UPH-415 UPH-416 QTY.9 UPH-408 UPH-413 CSG-402 CSG-402 UPH-413 CSG-402 CSG-407 UPH-404 QTY. 4 UPH-408 UPH-403 UPH-403 UPH-403 CSG-402 CSG-407 QTY. 2 CSG-407 CSG-407 UPH-413 9 9 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:32:38 PMENLARGED FURNITURE PLAN - LOBBY/LOUNGE/BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A401b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1114AENLARGED FURNITURE PLAN - LOBBY/LOUNGE/BAR KEYNOTES 1 08/25/2016 Revision 1 6 3/27/2017 RFI 73R1 Response 7 3/28/2017 RFI 71 Response 9 7/21/2017 CCD-005 9 08/02/2017 01/11/18 REFVAULTEDC GYP 9' - 0" A.F.F. C GYP 9' - 0" A.F.F. C EXIST 7' - 4" A.F.F. C WD-004 8' - 0" A.F.F. CLCL CL 2'-3" 6'-0" 6'-0" 2'-3"CLCL CL CL 5'-5" 5'-5" 5'-5" 2'-8"CLEQ EQC GYP 10' - 0" A.F.F. C GYP 10' - 0" A.F.F. CL CL CL6'-6"CL EQCLCL CL 2'-3" 6'-0" 6'-0" 2'-3" EXPOSED CONDUIT DIRECTLY ADJACENT TO GLU-LAM BEAM AS SHOWN EXPOSED CONDUIT DIRECTLY ADJACENT TO GLU-LAM BEAM AS SHOWN CL 4'-8 1/4"15'-1" 15'-1" 6'-6"EQ 5'-8" 5'-8" EQ CHECK-IN DESK BELOW BAR BELOW LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 SKI BOOT REMOVAL AREA 110 VESTIBULE 101 EXPOSED CONDUIT DIRECTLY ADJACENT TO GLU-LAM BEAM AS SHOWN 2'-0" 1'-6"2'-0"+/- 3'-6 3/4" 2'-0" CL 5'-0"EQ EQ C NEW 14' - 6 15/32" A.F.F. C GYP 13' - 4" A.F.F.2'-3"14'-0" 3'-10 1/2" 7'-11 7/8" 3'-10 1/2" 2'-6" 6'-4" 2'-6" EQ 3'-8 7/8"8'-8" 8'-8" 26'-0" 7'-8" CLCL3'-1 3/8" 8'-8" 7'-8" 4'-5 5/8" 4'-5 5/8"7'-0" 4'-6" +/- 4'-4"C GYP 13' - 4" A.F.F.REF FIREPLACE DETAILS FOR MORE INFORMATION 2.83 6E A401d WD-004 CLEQ EQ CLEQ 6A A401c 6B A401c EQ EQ EQ EQ EQC GYP 10' - 0" A.F.F. C EXPOSED VARIES C PDC-001 8'-0" A.F.F. HUNTER DOUGLAS 300C LINEAR PLANK SYSTEM 13 C EXIST 18' - 8 9/32" A.F.F. 3 1/2" 2'-0" BOTTOM OF EXSITING ROOF TRUSS 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING , ATTACH TO METAL STUD FRAMING 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING , ATTACH TO METAL STUD FRAMING SOFFIT WIDTH TO MATCH WINDOW OPENING WIDTH LINEAR HVAC DIFFUSER HVAC DIFFUSER BOX 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING , ATTACH TO METAL STUD FRAMING EXISTING PRECAST WALL 1'-6"2" 2'-0" BOTTOM OF EXSITING ROOF TRUSS 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING, RUN LONGITUDINAL TO SOFFIT, ATTACH TO METAL STUD FRAMING 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING , RUN LONGITUDINAL TO SOFFIT, ATTACH TO METAL STUD FRAMING SOFFIT WIDTH TO MATCH WINDOW OPENING WIDTH LINEAR HVAC DIFFUSER HVAC DIFFUSER BOX 1 5/8" METAL STUDS @16" O.C. MONARCH PLANKING , ATTACH TO METAL STUD FRAMING EXISTING PRECAST WALL 1'-6"2"3 1/2" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:06:35 PMENLARGED REFLECTED CEILING PLAN - LOBBY/LOUNGE/BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A401c 2211 N FRONTAGE RD, VAIL, COLORADO 81657 2.83 INFILL CHIMNEY FLUE HOLE. MATERIAL MATCH ADJACENT CONSTRUCTION. SCALE:1/4" = 1'-0"DRAWING REF: A1214AENLARGEDREFLECTED CEILING PLAN - LOBBY/LOUNGE/BAR KEYNOTES PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 WD-004 PNT-001 108/25/2016Revision 1 7 3/28/2017RFI 71 Response 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 SCALE: 1 1/2" = 1'-0"DRAWING REF: A401c6ALINEARDIFFUSERSOFFIT - TRANSVERSE PLANKS SCALE: 1 1/2" = 1'-0"DRAWING REF: A401c6BLINEARDIFFUSERSOFFIT - LONGITUDINAL PLANKS 12/05/2017 01/11/18 W WD-005 W WD-004 DIRECTION OF PLANKSC PNT-001 W VWC-602 GLASS FAB-10 REFER TO MILLWORK DETAILS & FF&E SPECIFICATIONSMTL-02 C PNT-001 WD-003 STN-001 13 B CTB-002 W WD-004 W PNT-001 SLOPED CEILING WALL EXTENDS TO B.O. GLU-LAM BEAM SLOPED CEILING OPEN TO CORRIDOR BEYOND LOBBY BAR, REF. MILLWORK SHEETS FOR DETAILS W WD-004 W WD-004 GLU-LAM BEAM BEYOND WALL EXTENDS TO B.O. GLU-LAM BEAM W WD-005 GLASS FAB-10MTL-02 MTL-01 WD-003 3C A502 W WD-004 W WD-004 ENGINEERED AIR DIFFUSER, DEE MECAHNICAL DRAWINGS, SHEET M202 ENGINEERED AIR DIFFUSER, SEE MECAHNICAL DRAWINGS, SHEET M202 EXISTING STRUCTURAL COLUMN BEYOND CONCRETE HEARTH EXTENT OF FIREBOX BEYOND OPEN OPEN OPEN OPEN OPEN CUSTOM FIREBOX TRIM LIGHTBOX, TYP, 3 7/8"H x 2"W x 1.38"D, 60X 12V CLASS 2 POWER SUPPLY, BLACK FINISH, DIMMABLE MANUFACTURED BY VOLT LIGHTING, LLC.CONTINUE 50% OFFSETBRICK PATTERNBEYOND LIGHTING AREA2'-8 3/4"2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4"2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 5/8" EQEQ 6E A401d W STN-003 W WD-004 C PNT-001 50% OFFSET BRICKPATTERNSTN-003 W WD-004 W WD-004 W WD-004 B CTB-002 W WD-004C PNT-001 W WD-004 B CTB-002 W STN-003 W LOCATION FOR EMERGENCY SHUT-OFF AND GAS VALVE CONCRETE HEARTH CUSTOM FIREBOX TRIM CHECK-IN DESK BEYOND PENDANT LIGHTING BEYONDOPEN OPEN OPEN OPEN OPEN CONCRETE HEARTH PRECAST REINFORCED CONCRETE SHELVES EXISTING STRUCTURAL COLUMN BEYOND LIGHTBOX, TYP, 3 7/8"H x 2"W x 1.38"D, 60X 12V CLASS 2 POWER SUPPLY, BLACK FINISH, DIMMABLE MANUFACTURED BY VOLT LIGHTING, LLC.CONTINUE 50% OFFSETBRICK PATTERNBEYOND LIGHTING AREAACCESS PANEL BEYOND 2'-8 3/4"2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" EQEQ 2'-8 3/4"2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" 2'-8 3/4" EQEQ 6E A401d W WD-004 B CTB-002 W WD-004 FIREPLACE IN FOREGROUND EXISTING WINDOWS TO REMAIN 50% OFFSET BRICKPATTERNW STN-003 W WD-004 TV 6A A401c 6B A401c EQ EQ BOTT./T.V.4'-1 1/2"5"5"NEW POWER; PROVIDE FROM NEAREST EXISTING WALL OUTLETWOOD FRAME AROUND TV MOUNT CL CL TO POWER/CABLE4'-9 1/2"CL TO T.V./T.V. MOUNT5'-9 1/2"NEW CABLE; PROVIDE FROM NEAREST EXISTING CABLE SOURCE B CTB-002 W VWC-602 OPEN CORRIDOR BEYOND W WD-004 C PNT-001 A401d 6E B CTB-002 2x6 SHIPLAP R.S. CEDAR PLANKS METAL PLANK CEILING WITH REMOVABLE PLANKS ON SUSPENDED ALUMINUM FRAME 3 5/8" METAL STUDS 2"COORDINATE LOCATION OF EXISTING STEEL BEAM WITH CEILING, FRAMING TO CLEAR BEAM 5/8" GYP BD ON 2 1/2" METAL STUDS FINISH AND STAIN EXPOSED FACES OF END PLANK TO MATCH 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:06:53 PMINTERIOR ELEVATIONS - LOBBY/LOUNGE/BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A401d 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE:1/4" = 1'-0"DRAWING REF: A401a3AELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A0106AELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A401a 6B ELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A401a3BELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A401a4DELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A401a6DELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A0413EELEVATION - LOBBY SCALE:1/4" = 1'-0"DRAWING REF: A401a5EELEVATION - LOBBY NOTE: CONTRACTOR TO PROVIDE BLOCKING ADJACENT TO ALL LIGHT BOXES NOTE: CONTRACTOR TO PROVIDE BLOCKING ADJACENT TO ALL LIGHT BOXES SCALE: 1" = 1'-0"DRAWING REF:A401c6ESECTION THROUGH SOFFIT AT LOBBY 1 08/25/2016 Revision 1 7 3/28/2017 RFI 71 Response 9 7/21/2017 CCD-005 10 9/15/2017 CCD-006 13 12/01/2017 CCD-09 12/05/2017 01/11/18 5 A501 6A A601 3B A601 6B A601 3B A604 4 A501 4B A601 1 A501 2 A501 6 A501 7 A501 8 A501 6A A601 1 A603 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:15:50 AMINTERIOR ELEVATIONS - LOBBY/LOUNGE/BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET A401e 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A401a2AELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a 5AELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a 5B ELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a2BELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a4DELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a 6D ELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a3EELEVATION - LOBBY SCALE: 1/4" = 1'-0" DRAWING REF: A401a 5E ELEVATION - LOBBY 7/11/16 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 14'-5 1/2" ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119ROOM 123 CORRIDOR 119B ROOM 124 9'-3 1/2" 9.16 8'-8" 122 121 120 124 123 119A A402 1C 4C 2C 3C A4a A4a A4a A4a F2a F2a F2a F2a F2a ALIGN 119B EQ S3 EQ F2a A4a F2a 8'-11 1/2"3'-8" 10'-6" 9'-0" 9'-0"4'-6" 2'-9 1/2" 1'-1"1'-0 3/4" C L 8'-0" A402 4D 3D A040 3E 4'-6 1/2" CL A4a ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 C ACT 8' - 5 1/2" A.F.F. C ACT 8' - 5 1/2" A.F.F. C ACT 8' - 5 1/2" A.F.F. C ACT 8' - 5 1/2" A.F.F. C ACT 8' - 5 1/2" A.F.F. C ACT 8' - 5 1/2" A.F.F.C ACT 8' - 5 1/2" A.F.F. CASED OPENING SIGNAGE BY MASSAGE TENANT V.I.F.6'-8"EQ EQ V.I.F.8'-5 1/2"6'-8"EQ EQ V.I.F.8'-5 1/2"EQ EQ 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:11:47 PMENLARGED PLANS - MASSAGE/ SPA THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A402 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 9.16 INFILL WITH METAL STUDS AND GYPSUM BOARD TO MATCH ADJACENT CONSTRUCTION. SCALE: 1/4" = 1'-0" DRAWING REF: A1112AENLARGED FLOOR PLAN - MASSAGE/ SPA SCALE: 1/4" = 1'-0" DRAWING REF: A1214AENLARGED REFLECTED CEILING PLAN - MASSAGE/SPA SCALE: 1/4" = 1'-0" DRAWING REF: A4021CELEVATION - MASSAGE/SPA WAITING SCALE: 1/4" = 1'-0" DRAWING REF: A0402CELEVATION - MASSAGE/SPA WAITING SCALE: 1/4" = 1'-0" DRAWING REF: A4023CELEVATION - MASSAGE/SPA WAITING SCALE: 1/4" = 1'-0" DRAWING REF: A0404CELEVATION - MASSAGE/SPA WAITING SCALE: 1/4" = 1'-0" DRAWING REF: A4024DELEVATION - MASSAGE/SPA CORRIDOR SCALE: 1/4" = 1'-0" DRAWING REF: A4023DELEVATION - MASSAGE/SPA CORRIDOR 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 10/17/2016 01/11/18 Ref. Under Counter MEETING ROOM 127 BOARDROOM 126 A403 2B A403 2C 3C 5C 6C 3B6B 5B 127 126 F2aF2a A4a A4a 2A A604 2A A604 SIM 2A A604 SIM 5'-0" HOLD 3'-5 1/2"5'-0"F2a A4a A4a A4a 9'-9 3/4"+/- 22'-5 3/4" V.I.F.+/- 23'-6 1/2" V.I.F. A4a 5'-0" ALIGN7" +/-9 1/2" +/-VERIFY GYP. BD. BYPASSES EXISTING STRUCTURAL ELEMENTS PRIOR TO CONSTRUCTING FURRED OUT WALL 9 MEETING ROOM 127 BOARDROOM 126 CL CL 3'-2 3/4" 3'-2 3/4" EQ CLEQ EQ C ACT 8' - 6" A.F.F. C GYP 8' - 0" A.F.F. C GYP 7' - 6" A.F.F.CLEQ EQ CL CL EQ EQ EQ CL CL EQ EQ EQ C ACT 8' - 6" A.F.F. C GYP 8' - 0" A.F.F. C GYP 7' - 6" A.F.F. CL 3'-3" CL1'-10" 3'-4 3/4"CL EQ EQ CLEQ EQRECESSED PROJECTION SCREEN 2'-5"2'-5"2'-5" EQ EQ EQ EQCL 6'-0"EQ 10'-0" EQ2'-0" 1'-3 1/8"2'-0"5 3/8" EQ EQ EQ +/- 4'-3 1/4" +/- 4'-3 1/4" EQ EQEQ EQ 2'-0" 2'-0"C L EQ EQ EQ EQ 2'-0"2'-0" 6'-0" 3'-0" 6'-0" EQ 10'-0" EQCLCL EQ EQC ACT 8' - 6" A.F.F. C GYP 7' - 6" A.F.F. PENDANT LED LINEAR LIGHT RECESSED LED LINEAR LIGHT, TYP. 1'-6"1'-6" CL CL PROJECTION SCREEN (OFCI) B WB-001 W VWC-601 RECESSED LED LINEAR LIGHT, TYP. PNT-001 B WB-001 W VWC-601 RECESSED LED LINEAR LIGHT BEYOND PNT-001 STN-002 WD-002+/- 1" FILL 2'-6" 2'-9" 2'-6"3'-3" 2A A604 2A A604 SIM 3'-3" 3'-3" B WB-001 W VWC-601RECESSED LED LINEAR LIGHT, TYP. +/- 1/2" FILL +/- 1/2" FILL +/- 1" FILL 2'-10"W VWC-601 PNT-001 WD-002 STN-002 STN-002 WD-002 B WB-001 W VWC-601 RECESSED LED LINEAR LIGHT BEYOND PNT-001 B WB-001 W VWC-601 PENDANT LED LINEAR LIGHT PNT-001 STN-002 WD-002 1" 2'-0 1/2"2'-3" 2'-3" 2'-3" +/- 1 1/2" FILL 2A A604 SIM W VWC-601 PENDANT LED LINEAR LIGHT 2'-10"STN-002 WD-002 PNT-001 REFRIGERATOR LOCATED BEHIND CABINET DOORS. PROVIDE NECESSARY VENTING IN PLINTH. COORDINATE WITH SPECIFICATION. B WB-001 W VWC_601 PENDANT LED LINEAR LIGHT WD-002STN-002 TVCL 5'-0" AFFB WB-001 W VWC-601 MOUNTING BRACKET PENDANT LED LINEAR LIGHT PNT-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:33:13 PMENLARGED PLANS - MEETING ROOMS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A403 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1113AENLARGED FLOOR PLAN - MEETING ROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A1215AENLARGED REFLECTED CEILING PLAN - MEETING ROOMS KEYNOTES SCALE: 1/4" = 1'-0" DRAWING REF: A4032BELEVATION - MEETING ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4033BELEVATION - MEETING ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4035BELEVATION - MEETING ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4036BELEVATION - MEETING ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4032CELEVATION - BOARDROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4033CELEVATION - BOARDROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4035CELEVATION - BOARDROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4036CELEVATION - BOARDROOM 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 9 7/21/2017 CCD-005 08/02/2017 01/11/18 REF OFFICE 1 132 OFFICE 3 130 OFFICE 4 129 RECEPTION 128 132 130 129 128 A4a F2a F2a A4a A4a A4a A4a F2a EQ ALIGN F2aF2a 9'-6 3/4" 4 1/4" A4a A4a A4a F2a F2a 4'-2 1/2"5'-0" EQ OFFICE 2 131 128A 131 EQ 7'-10 3/4" 2'-8" 9'-0" CLR 9'-10" CLR3'-6" MIN ALIGN EMPLOYEE BREAK ROOM 136 M EMPLOYEE LOCKER ROOM 138 9.18 4'-1" 4'-1" 9.18 135 137 138 A404 2D 3D A404 5D 6D A404 3.2 3.2 A4a F2a F2a F2a A4a F2a 10'-5 1/2"2'-8" MIN 1'-6" MIN 5'-0" MIN CLR A4a 2'-8" 5'-0" MIN CLR 1'-6" MIN 17'-11 3/4" 4 3/4" STORAGE 135 W EMPLOYEE LOCKER ROOM 137 3E 2 1/2" A4aA4a F2a F2a A4a A4a F4a F4a A4a F2a F2a F2a REF 4'-6" R.O.4'-0" MIN CLRMIN CLR 5'-0" 5'-0" MIN CLR 5'-0" MIN CLR 5'-0" MIN CLR 3'-4" MIN0" 5'-0" MIN 1'-3" MIN 2'-6" MIN 1'-3" A6a MIN 1'-3" MIN 2'-6" MIN 1'-3"3'-4" MIN 4'-2 7/8" SCREEN2'-0" PRIVACYA604 2D SIM A604 2D SIM 136 VEND VEND 4E 5'-0"20" MIN KITCHEN STORAGE 142 A4aA4a A4a 9 F4aF4a F1a F4a 3'-10"11'-7" MIN 1'-6"8 3/4" +/-152 VERIFY GYP. BD. BYPASSSES EXISTING STRUCTURAL ELEMENTS PRIOR TO CONSTRUCTING FURRED OUT WALL 5'-0" A404 6E 5E OFFICE 1 132 OFFICE 3 130 RECEPTION 128 OFFICE 4 129 C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. C ACT 8' - 0" A.F.F. OFFICE 2 131 EMPLOYEE BREAK ROOM 136 M EMPLOYEE LOCKER ROOM 138 C GYP 6' - 0" A.F.F. C ACT 8' - 0" A.F.F. C GYP 6' - 0" A.F.F. C ACT 8' - 0" A.F.F. C GYP 11' - 7 3/4" A.F.F. C ACT 8' - 0" A.F.F. STORAGE 135 W EMPLOYEE LOCKER ROOM 137 C ACT 8' - 0" A.F.F. COORDINATE WITH LOCKERS BELOW 8'-0"1'-3"1'-6"8 B CTB-003 W PNT-008 W CT-004 2E A604 SIM PROVIDE ALL CURTAINS, RODS AND HOOKS TO CLOSE OPENING 8 3A A604 B CTB-003 W PNT-008W CTB-004 W PNT-008 W CT-004 REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A6043'-2"FINISH TOP EDGE OF TILE WITH ALUMINUM SCHLUTER SCHIENE STRIP SSM-01 3A A604 B W W WW REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A604 3'-2"FINISH TOP EDGE OF TILE WITH ALUMINUM SCHLUTER SCHIENE STRIP B W W 2E A604 SIM PROVIDE ALL CURTAINS, RODS AND HOOKS TO CLOSE OPENING WATER BOX OUTLET FOR REF. VALENCE TO HIDE UNDERCABINET LIGHTING, TYP.1'-6"EQ VIF EQ 3'-0" 2'-6"2'-6" 4A A604 5A A604 6A A604 2'-10" 1'-8" 3'-0"W PNT-006 B VB-003 W PNT-006 B VB-003 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:33:31 PMENLARGED PLANS - BACK OF HOUSE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A404 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1112AENLARGED FLOOR PLAN - BACK OF HOUSE SCALE: 1/4" = 1'-0" DRAWING REF: A1114AENLARGED FLOOR PLAN - EMPLOYEE BREAKROOM & LOCKER ROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A1212BENLARGED REFLECTED CEILING PLAN - BACK OF HOUSE SCALE: 1/4" = 1'-0" DRAWING REF: A1214BENLARGED REFLECTED CEILING PLAN - EMPLOYEE BREAKROOM AND LOCKER ROOMS KEYNOTES 3.2 NEW CONCRETE SLAB. SEE STRUCTURAL DRAWINGS. 9.18 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS, CONTROLS, CURTAIN & ROD. SCALE: 1/4" = 1'-0" DRAWING REF: A4042DELEVATION - M EMPLOYEE LOCKER ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4043DELEVATION - M EMPLOYEE LOCKER ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4045DELEVATION - W EMPLOYEE LOCKER ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4046DELEVATION - W EMPLOYEE LOCKER ROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4043EELEVATION - EMPLOYEE BREAKROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1114EELEVATION - EMPLOYEE BREAKROOM 1 08/25/2016 Revision 1 8 CCD-04-Exterior 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A111 5E ELEVATION - STORAGE SCALE: 1/4" = 1'-0" DRAWING REF: A111 6E ELEVATION - STORAGE 9 08/02/2017 01/11/18 BALLROOM/ MEETING ROOM 104 104B 9.16 A405 4D 6E 4E 6D F4a A4a 104D A6a MEETING STORAGE 153 6'-0" 3'-3"F3a S9 S8 S8 S9 +/- 21'-2 1/4" 2'-7 1/2"S10 F2a F2a STRUCTURAL INFILL - SEE STRUCTURAL DRAWINGS STRUCTURAL INFILL - SEE STRUCTURAL DRAWINGS ALIGN 104C A604 5E 13'-8" 18'-6 1/4" A6a F4a F4a A9a 153 9 BALLROOM/ MEETING ROOM 104 C ACT 8' - 0" A.F.F. C NEW 10' - 0" A.F.F. MEETING STORAGE 153 23.4 23.4 6'-4" 1'-0" 14'-0" 1'-0" 14'-0" 1'-0" +/- 6'-6 1/2"+/- 8'-4"1'-0" 14'-0" 1'-0" 14'-0"1'-0" +/- 8'-4" C GYP 7' - 2" A.F.F. C GYP 9' - 0" A.F.F. RECESSED PROJECTION SCREEN EQ EQ EQ2'-9" C GYP 11' - 2 3/8" A.F.F. 1'-0 1/8" 2'-0 3/8" 31'-0"31'-0"5'-1 3/4" 5'-1 3/4" 14'-2 3/4" 9'-6 1/4"4'-8"1'-6" EQ EQ EQ EQ EQ1'-6"4'-8"1'-6" 1'-6" EQ EQ EQ EQ EQ EQ EQ EQ EQ EQDIRECTION OFWOOD PLANKSTYP, FOUR SIDESTYP, FOUR SIDES 4 1/2"CL CL 23.4 TYP, FOUR SIDES 23.4 TYP, FOUR SIDES MECHANICAL AIR SUPPLY SLOT MECHANICAL AIR SUPPLY SLOT 0" C GYP 9' - 0" A.F.F.C GYP 8' - 0" A.F.F.RECESSED POCKET, REF DOOR DETAILS PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 CL 4'-6"9 9'-0"A405 1D Sim TYP PROJECTION SCREEN B WB-001 W WD-002 W WD-002 WD-002 PNT-001 A405 1D Sim TYP B WB-001 W VWC-600 W VWC-600 W VWC-600 PNT-001 A405 1D Sim TYP STN-002 WD-002 W VWC-600 PNT-004 W VWC-600 B WB-001 PEMKO SIM 150-5: CUSTOM WOOD FINISH TO MATCH WD-002. SAMPLES TO BE SUBMITTED TO DESIGN FOR APPROVAL 6'-0"9 A405 1D TYP PNT-001 W VWC-600 W VWC-600 B WB-001 BOTTOM OF JOISTS 11' - 3" AFF CEILING BEYOND 5/8" GYP LED STRIP LIGHTING WITH DIFFUSER 5/8" GYP, TYP HUNTER DOUGLAS 300C CARRIER FACTORY PANEL END 1'-0" METAL STUD FRAMING BETWEEN JOISTS ENGINEERED SLOT RETURN 2" 2 1/2"HUNTER DOUGLAS 1 3/16" x 5 1/2" 300 C PANEL DECORATED (POWDER COATED) WOOD FINISH1'-0" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:33:41 PMENLARGED PLANS - BALLROOM THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A405 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1113AENLARGED FLOOR PLAN - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1215AENLARGED REFLECTED CEILING PLAN - BALLROOM KEYNOTES 9.16 INFILL WITH METAL STUDS AND GYPSUM BOARD TO MATCH ADJACENT CONSTRUCTION. 23.4 REFER TO MECHANICAL DRAWINGS FOR ENGINEERED RETURN AIR SLOT. SCALE: 1/4" = 1'-0" DRAWING REF: A405 4D ELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4056DELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4054EELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4056EELEVATION - BALLROOM SCALE: 1" = 1'-0" DRAWING REF: A4051DDETAIL - COVE LIGHT NOTE: ARCHITECT APPROVAL FOR SPRINKLER HEAD LOCATION REQUIRED 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 08/02/2017 01/11/18 FITNESS CENTER 148 GUEST LAUNDRY 147 9.20 11.1 147 148A A4a A4a 3.1 A406 5E 6E 3E3D A4a9'-10 1/2"F2a S2 1D A604 A4a F2a F2a F2a 2'-0" MAX3'-6" MIN F2a COORDINATE WALL LOCATION WITH EXISTING COLUMN .COORDINATE LENGTH OF CASEWORK WITH LOCATION OF ADJACENT WALLS 3'-4 1/8"HYDRATION STATION MOUNT AT 7' - 0" AFF WITH ARTICULATING ARM MOUNT, BRACKET AND BLOCKING MOUNT AT 7' - 0" AFF WITH BRACKET AND BLOCKING REFER TO HILTON APPROVED PLAN FROM LIFE FITNESS FOR EQUIPMENT SPECIFICATIONS AND DETAILS FITNESS CENTER 148 GUEST LAUNDRY 147 C GYP 9' - 0" A.F.F. C EXIST 11' - 5 3/4" A.F.F. C EXIST 8' - 2" A.F.F. C EXIST 11' - 0 1/4" A.F.F. CLCL EQ 6'-0" EQ CLEQEQ C GYP 8' - 0" A.F.F. C GYP 11' - 0 1/4" A.F.F. MATCH CEILING TO EXISTING CEILING HEIGHT C GYP 11' - 5 3/4" A.F.F. CJ CLCL CL CL 6'-0" 6'-0" 6'-0" 6'-0" 2'-9 1/2"CL CL CL CL CL CL6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" CL CL6'-0" CL C GYP 8' - 0" A.F.F. EQ EQ EQ EQ CL CL 2'-0" 2'-6 1/8" 1'-6"EQ EQ EQEQ EQ EQ 6'-0"8'2" MATCH CEILING TO EXISTING CEILING HEIGHT C GYP 8' - 2" A.F.F. MADE MARKET 105 4D A4a 5'-10 1/2" 4'-2" S4 A4a A4b F2a F2a F2a F2a A4a 15'-9 1/2"A601 2A 5D A406 6D A2a A2a REF SHEET A040 7/8" MIN 20'-11" 6A A406 W1a 3'-4"9 A4a 3'-0"1'-1" 17'-1 1/4" 1'-1" C GYP 9' - 0" A.F.F. MADE MARKET 105 CL 4'-5 1/4" 6'-0" 6'-0" CL3'-10 3/4"EQ 8'-0"CLEQ EQ 2'-0"CL CL A601 2C6A A406 PNT-001 EQCLCL 3'-4" 9 CLEQ EQ CLEQ CLCL 1'-7" B CTB-002 W VWC-500 REFER TO APPROVED HILTON FLOOR PLAN & 2016 HILTON APPROVED WARM SCHEME FOR FINISH SPECIFICATIONS AND LOCATIONS REFER TO APPROVED HILTON FLOOR PLAN & 2016 HILTON APPROVED WARM SCHEME FOR FINISH SPECIFICATIONS AND LOCATIONS REFER TO APPROVED HILTON FLOOR PLAN & 2016 HILTON APPROVED WARM SCHEME FOR FINISH SPECIFICATIONS AND LOCATIONS REFER TO APPROVED HILTON FLOOR PLAN & 2016 HILTON APPROVED WARM SCHEME FOR FINISH SPECIFICATIONS AND LOCATIONS 6A A406 W VWC-500 B CTB-002 CHALKBOARD FINISH PLAM-002 STN-002 PLAM-002 PLAM-002 CT-002 9 PLAM-002 CHALKBOARD FINISH 2'-10" METAL WRAPPED MDF COUNTER 1 1/2"CHARRED WOOD 3/4" PLYWOOD 3 5/8" METAL STUD 5/8" GYP BD 3/4" WOOD TRIM BASE AS SCHEDULED EDGE OF WALL BEYOND4'-0" R.O.3/4"x3/4" ALUMINUM REVEAL, XTREME TRIM OUTSIDE CORNER REVEAL X0CR34M, OR EQUIVALENT, MITER JOINTS WHERE VERTICAL AND HORIZONTAL REVEALS MEET A602 4E 2'-0" 5" 6" ELECTRICAL AND DATA OUTLETS, SEE ELECTRICAL DRAWINGS 5/8" GYP BD, SHIM WHERE NECESSARY PROVIDE GROMMET 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:33:54 PMENLARGED PLANS - FITNESS, GUEST LAUNDRY, AND MADE MARKET THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A406 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1112AENLARGED FLOOR PLAN - FITNESS ROOM & GUEST LAUNDRY SCALE: 1/4" = 1'-0" DRAWING REF: A1213AENLARGED REFLECTED CEILING PLAN - FITNESS & G. LAUNDRY KEYNOTES 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 9.20 COLUMN WRAP. 11.1 RELOCATED FRONT LOADING AND ACCESSIBLE WASHER AND DRYER. SCALE: 1/4" = 1'-0" DRAWING REF: A1115AENLARGED FLOOR PLAN - MADE MARKET SCALE: 1/4" = 1'-0" DRAWING REF: A1215BENLARGED REFLECTED CEILING PLAN - MADE MARKET SCALE: 1/4" = 1'-0" DRAWING REF: A4064DELEVATION - MADE MARKET SCALE: 1/4" = 1'-0" DRAWING REF: A406 6E ELEVATION - FITNESS SCALE: 1/4" = 1'-0" DRAWING REF: A0403DELEVATION - FITNESS SCALE: 1/4" = 1'-0" DRAWING REF: A406 5E ELEVATION - FITNESS SCALE: 1/4" = 1'-0" DRAWING REF: A0403EELEVATION - FITNESS SCALE: 1/4" = 1'-0" DRAWING REF: A4066DELEVATION - MADE MARKET SCALE: 1/4" = 1'-0" DRAWING REF: A4065DELEVATION - MADE MARKET SCALE: 1 1/2" = 1'-0" DRAWING REF: A401bx6ASECTION - MADE MARKET TRANSACTION COUNTER 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 08/02/2017 01/11/18 A410 4B A410 5B 2B6B F1a F4aA4a A4a A4a 149 150F4a A4a A4aA4a TA-6 TA-1 TA-3 TA-23 TA-1 TA-3 TA-9 7'-4"5'-0" MIN CLR5'-2" 3'-0" 3'-0"3'-0" 3'-0" 3'-0"5'-0"5'-0" F2a F2a WOMEN'S 150 MEN'S 149 F4a F4a 5'-8"5'-8" F4a F4a F4a ALIGN 20" MIN 5'-0" MIN CLR5'-2"3'-0" 3'-0" 3'-0" 3'-0" 3'-0"1'-3" MIN EQ EQ EQ 1'-3" MIN 1'-6"2'-2"2'-2"CLCL CL CL1'-6"1'-3" MIN EQ EQ EQ 1'-3" MIN TA-12 TA-12 TA-2 TA-2 TA-9 TA-6 TA-23 TA-23 TA-23 TA-23 TA-23 TA-23 TA-23 TA-23 MIR-800 MIR-800 ART-800ART-800 ACC-800 ACC-800 ACC-800 ACC-800 A410 3D A410 5C 6D 5D 4D 6C 3C 4C TA-2 TA-3 TA-23 TA-1 TA-3 TA-23 TA-3 TA-3 F2a A4a 141 139 A4a F4a A4a F2a A604 2D 9.18 9.18 A4a A4a A6a F2a WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 3'-6"CL 3'-6" CLSCREEN2'-0" PRIVACYMIN 1'-3" MIN 2'-6" MIN 1'-3" 5'-0" MIN CLR 13'-4 3/4"12'-10 1/2" 5'-0" MIN CLR 5'-0" MIN CLR +/- 2'-11 3/8"5'-0" 3'-4"1'-8" 5'-0" MIN CLR 5'-0" MIN CLR +/- 2'-11 3/8" 5'-0"3'-4" 1'-8"5'-0" MIN CLR MIN 1'-3" MIN 2'-6" MIN 1'-3"20" MIN A604 2D SIM TA-1 TA-17 TA-21 TA-2 TA-17 TA-21 TA-23 TA-12 CL2'-11" 9 TA-26 9 TA-26 9 B CTB-004 W VWC-800 W CT-006 1'-0" 5'-0"PARTITIONS 8" FROM FINISHED CEILING, DOORS 5'-0"H, 1'-0"AFF, SUPPORTS FULL HEIGHT B CTB-004 W VWC-800 W CT-006 PARTITIONS 8" FROM FINISHED CEILING, DOORS 5'-0"H, 1'-0"AFF, SUPPORTS FULL HEIGHT B CTB-004 W VWC-800 3B A604 BABY CHANGING STATION (N.I.C) 40" MAX TO BOTTOM OF REFLECTIVE SURFACE PENDANT LIGHT, TYP, REF SPECIFICATIONS STAINLESS STEEL AUTOMATIC PAPER TOWEL DISPENSER TURN COUNTER MATERIAL VERTICALLY AT ENDS, TYP BOTH SIDES, SECURE TO FLOOR WITH METAL ANGLE AND BOLT ON INSIDE FACE REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A604 W VWC-800 FRAMELESS MIRRORS (4x) PROVIDED AND INSTALLED BY GC W VWC-801 W VWC-801 EQ EQ 1'-6"3B A604 SIM BABY CHANGING STATION (N.I.C) STAINLESS STEEL AUTOMATIC PAPER TOWEL DISPENSER PENDANT LIGHT, TYP, REF SPECIFICATIONS TURN COUNTER MATERIAL VERTICALLY AT ENDS, TYP BOTH SIDES, SECURE TO FLOOR WITH METAL ANGLE AND BOLT ON INSIDE FACE REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A604 SEE FRAMELESS MIRROR LOCATION AND WALL FINISHES NOTED ON ELEVATION 2B *SEE FINISH INFORMATION & MOUNTING HEIGHTS FOR FULL LENGTH MIRROR NOTED ON ELEVATION 2B* B CTB-003 W PNT-007 W PNT-007 W CT-004 3A A604 4'-0"40" MAX TO BOTTOM OF REFLECTIVE SURFACE REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A604 PARTITIONS AND DOORS 5'-0"H, 1'-0"AFF T-6 TA-26 9 B CTB-003 W CT-004 W PNT-007 3A A604 4'-0"40" MAX TO BOTTOM OF REFLECTIVE SURFACE REMOVABLE PANEL, ENSURE KNEE AND TOE CLEARANCE MEETS ADA STANDARDS, REF DETAIL 3B/A604 PARTITIONS AND DOORS 5'-0"H, 1'-0"AFF W CT-004 T-6 TA-26 9 C ACT 8' - 0" A.F.F. WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 C ACT 8' - 0" A.F.F. C GYP 8' - 0" A.F.F. C GYP 8' - 0" A.F.F. CL 2'-10" CL2'-10" C GYP 8' - 0" A.F.F.CLCL CL 3'-1" 3'-1" 2'-11"CL 1'-0"CLCL CL3'-0" 3'-0" 3'-0"MEN'S 149 WOMEN'S 150 EQ EQ1'-0"EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 3'-0" EQ EQEQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 3'-0" 1'-1 1/2" CLCL CL EQ EQ EQ EQEQ EQ EQ EQCLEQ EQ EQ EQEQ EQ EQ EQ 3'-1 1/2" 3'-0" C PNT-001 C PNT-001 C PNT-001 B CTB-003 W PNT-007 PROVIDE ALL CURTAINS, RODS AND HOOKS TO CLOSE OPENING 2E A604 SIM B CTB-003 W PNT-007 B CTB-003 W CT-004 B CTB-003 W CT-004 PROVIDE ALL CURTAINS, RODS AND HOOKS TO CLOSE OPENING W PNT-007 2E A604 SIM BABY CHANGING STATION (N.I.C) 9 B CTB-003 W PNT-007 B CTB-003 W CT-004 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:34:11 PMENLARGED TOILET PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A410 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 9.18 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS, CONTROLS, CURTAIN & ROD. SCALE: 1/4" = 1'-0" DRAWING REF: A1112APLAN -PUBLIC RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A1114APLAN -POOL RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A410 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4102BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 5C ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4103DELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A1215ARCP -POOL RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A1213ARCP -PUBLIC RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF: A410 5D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 4D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 6D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4103CELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 4C ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A410 6C ELEVATION 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 08/02/2017 01/11/18 KAL 204 A430 2C 3C 4C 5C A430 2B 4B 5B 6B MIN 1'-6" 8.1 8.6 4.1 8.7 27.1 23.2 8.8 8.10 23.1 26.3 26.6 26.6 22.6 22.4 22.8 8.18 GR-E GR-A A4a F4a 23.3 MIN 4'-11"2'-9" 3'-0" 3'-3"1'-4"MIN1'-0"22.5 8.16 A501 1C GR-G A002b 4B CL EQ EQ 2'-0" CLR 10.2 1A A500 SIM KAL 204 2.25 2.14 2.22 2.15 2.30 2.9 2.17 2.16 2.30 2.71 2.19 2.4 2.43 2.7 2.1 2.5 2.3 2.4 2.43 2.73 2.70 2.70 2.70 2.70 2.70 2.3 2.24 KAL 204 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001 W WD-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B VB-001 T-01 T-02 9.2 W SRD-001 ALIGN KAL 204 LTG-100 LTG-101 TA-23 WTR-102 & WTR-103 TA-1 TA-2 TA-17 CL CL3'-5".4'-6" CSG-100* MIR-100 EQU-101.1 LTG-102 UPH-100 UPH-100.1 ART-100 ART-101 ART-102 CSG-100* BED-101 BED-102 BED-101.1 BED-100 CSG-101 MIR-202 CSG-116L 8.17 BACKLIT, COORD. W/ ELEC. 10.1 TA-7MIR-203 ART-200 TA-24 10.3 1'-8" TA-19 TA-21 TA-17 TA-6 9 9 B VB-001 W PNT-008 WTR-102 & WTR-103 W WD-001 B VB-001 CSG-101 LTG-101 CLCL 7'-2" 4'-6"5'-0"7'-4"B VB-001 CL4'-6"CLCL EQ 2'-2" EQ NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. W PNT-008 T PNT-002 B VB-001 CL4'-6"B VB-001 W PNT-008 CL4'-6"MIR-100 EQU-101.1 UPH-100 UPH-100.1 LTG-102 CLCL 9'-0 1/4" 5'-3" B VB-001 1'-0"W SRD-001 4'-0" MAX AFFCL9" B CTB-001 W VWC-200W SRD-001 REMOVABLE PANEL TO B.O. REFLECTIVE SURFACE3'-4" MAX2C A501 4'-9"4'-2"B CTB-001 W VWC-200 4'-2"10" B CTB-001 W VWC-200 W SRD-001 T PNT-002 2'-4 1/2" CLEQ EQ 4'-0" MAXEQ 2 EQ 2 KAL 204 C EXIST 7' - 4" A.F.F. MATCH ADJACENT 9.6 9.6 9.6 26.7 26.7 26.7 C PNT-001 7' - 0" AFF + - C PNT-001 7' - 0" AFF + - C PNT-001 8' - 0" AFF + - A500 6B SIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:34:26 PMENLARGED ACCESSIBLE GUESTROOM PLANS - KAL (ROOM 204) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A430 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -KAL KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.24 REMOVE SHELF AND ROD. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.71 REMOVE WC. 2.73 REMOVE SHELF. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.17 PROVIDE LOOP HANDLES FOR CURTAIN OPERATION AT 15-48" AFF. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.2 PROVIDE SHELF AND ROD AT ACCESSIBLE HEIGHT 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND DIVERTER. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN -KAL SCALE: 1/4" = 1'-0"4A FINISH PLAN - KAL SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KAL SCALE: 1/4" = 1'-0" DRAWING REF: A4302BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A430 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A430 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A430 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4302CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4303CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4304CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4305CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - KAL 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 99 9 9 9 08/02/2017 01/11/18 KAR 203 8.10 23.2 26.3 23.3 8.8 26.6 26.6 8.1 4.1 8.7 A431 2B 3B 5B 6B A431 2C 3C 4C 5C GR-A MIN 1'-6" 8.6 8.18 27.1 22.6 22.4 MIN 4'-11"2'-8" 3'-0" 3'-5 1/2"1'-4"F4a F4aA4a GR-E 22.523.1 8.16 2'-0" CLR A501 1C GR-G A002b 4B 22.8 CL EQ EQ 10.2 1A A500 SIM KAR 203 2.3 2.15 2.16 2.17 2.14 2.25 2.9 2.5 2.22 2.19 2.30 2.1 2.7 2.3 2.4 2.43 2.4 2.43 2.70 2.70 2.70 2.702.73 2.71 KAR 203 TA-7 TA-3 TA-23 TA-1 WTR-102 & WTR-103 LTG-100CL 3'-6"EQU-101.1 LTG-102 ART-100 CSG-100* UPH-100 UPH-100.1 ART-102 ART-101 LTG-101 CSG-100* CSG-101 BED-100 BED-101 BED-101.1 BED-102 TA-2 CSG-116R MIR-202 BACKLIT, COORD. W/ ELEC. 10.1 ART-200 TA-24 MIR-203 10.3 TA-19 TA-21 TA-17TA-6 9 9 KAR 203 WSRD-001 T-01 T-02 F CPT-100 C PNT-001 W PNT-008 B VB-001 W WD-001 F CT-001 B VB-001 C PNT-001 F CT-001 W VWC-200 B CTB-001 9.2 ALIGN KAR 203 C EXIST 7' - 4" A.F.F. 9.6 9.6 26.7 26.7 26.7 MATCH ADJACENT + - 9.6 C PNT-001 C PNT-001 7' - 0" AFF + - 7' - 0" AFF + - C PNT-001 8' - 0" AFF A500 6BSIM W WD-001T PNT-002 B VB-001 LTG-101 WTR-102 & WTR-103 5'-0"2'-4 1/2" 4'-6" 7'-7 3/4"CL4'-6"CLCL EQ 2'-2" EQ NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. B VB-001 W PNT-008 WTR-102 & WTR-103 B VB-001 W PNT-008 CL4'-6"CL 3'-6" EQU-101.1 ART-100 B VB-001 W PNT-008 T PNT-002 CL4'-6"ART-101 ART-102 B CTB-001 W VWC-200 4'-0" MAX AFFCL9" B CTB-001 W VWC-200 W SRD-001 REMOVABLE PANEL TO B.O. REFLECTIVE SURFACE3'-4" MAX2C A501 4'-9"B CTB-001 W VWC-200 W SRD-001 4'-2"10" B CTB-001 W VWC-200W SRD-001 T PNT-002 CLEQ EQ 4'-0"EQ 2 EQ 2 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:34:43 PMENLARGED ACCESSIBLE GUESTROOM PLANS - KAR (ROOM 203) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A431 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.71 REMOVE WC. 2.73 REMOVE SHELF. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.2 PROVIDE SHELF AND ROD AT ACCESSIBLE HEIGHT 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND DIVERTER. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN - KAR SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN - KAR SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KAR SCALE: 1/4" = 1'-0"4AFINISH PLAN - KAR SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - KAR SCALE: 1/4" = 1'-0" DRAWING REF: A431 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A431 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A431 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4312BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4312CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4313CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4314CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A431 5C ELEVATION - BATHROOM 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 99 9 08/02/2017 01/11/18 KARI 237 A432 2C 3C 4C 5C A432 2B 4B 5B 6B 23.2 8.8 8.6 8.7 27.1 8.18 MIN 1'-6" 26.6 GR-E GR-A3'-0"3'-0" 2'-11 7/8" 1'-6 1/8" MIN 4'-11"1'-4"F4a F4a F2a A4a 5'-2" 5 5/8" 8.9 23.3 23.1 26.3 22.6 22.5 8.1 22.9 4.1 8.16 ALIGNCLR2'-0"CLEQ EQ A501 1C GR-G A002b 4A 10.2 1A A500 SIM 9 KARI 237 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001W WD-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B VB-001 ALIGN T-01 T-02 9.2 WSRD-001 KARI 237 2.1 2.30 2.5 2.7 2.3 2.4 2.43 2.15 2.16 2.17 2.14 2.22 2.19 2.25 2.3 2.4 2.43 2.70 2.70 2.71 2.73 2.70 2.87 KARI 237 LTG-101 LTG-100 TA-7 TA-23TA-1 TA-17 TA-2 MIR-100 EQU-101.1 CLCL 4'-8" 9'-2"ART-100 LTG-102 WTR-100 & WTR-101 UPH-100 UPH-100.1 ART-101 ART-102 CSG-101 CSG-100* CSG-100* BED-100 BED-101 BED-102 BED-101.1 CSG-116L MIN 1'-6"1'-11" 4'-11" 3'-0"MIR-202 BACKLIT, COORD. W/ ELEC. 10.1 ART-200 TA-24 MIR-203 10.3 TA-26 9 TA-19 TA-21 TA-17 TA-13 B CTB-001 W SRD-001 4'-0" MAX AFFTA-26 96'-2"B CTB-001 W VWC-200 REMOVABLE PANEL W SRD-001 TO B.O. REFLECTIVE SURFACE3'-4" MIN2C A501 4'-9"B CTB-001 W VWC-200 TA-23 4'-2"10" B CTB-001 W VWC-200 T PNT-002 W SRD-001 CLEQ EQ 4'-0" MAXEQ2 B VB-001 W PNT-008 WTR-100 & WTR-101 W WD-001 W PNT-008 B VB-001 LTG-101CSG-101 6'-9 7/8" 4'-9"5'-0" AFFCL4'-6" CLCL EQ 2'-2" EQ NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. W PNT-008 T PNT-002 B VB-001 B VB-001 W PNT-008 EQU-101.1 ART-100 LTG-102MIR-100 WTR-100 & WTR-101 CLCL 9'-2" 4'-8" 1'-0"CL4'-6" C EXIST 6' - 11" A.F.F. 0" C GYP 7' - 0" A.F.F.MATCH ADJACENT 9.6 9.6 26.7 26.7 26.7 + - + - + - 9.6 C PNT-001 7' - 0" AFF C PNT-001 7' - 0" AFF C PNT-001 8' - 0" AFF A500 6B SIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:34:58 PMENLARGED ACCESSIBLE GUESTROOM PLANS - KARI (ROOM 237) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A432 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.71 REMOVE WC. 2.73 REMOVE SHELF. 2.87 REMOVE ROLL IN SHOWER. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.2 PROVIDE SHELF AND ROD AT ACCESSIBLE HEIGHT 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.9 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS, CONTROLS, CURTAIN & ROD. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN - KARI SCALE: 1/4" = 1'-0"4AFINISH PLAN - KARI SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN - KARI SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KARI SCALE: 1/4" = 1'-0" DRAWING REF: A4322CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4323CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A432 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4325CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4322BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A432 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A432 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A432 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - KARI 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 QQARI 235 A434 2C 3C 4C 5C A434 2B 4B 5B 6B 8.1 23.2 8.8 8.9 4.1 8.6 8.7 27.1 23.1 22.58.18 26.6 MIN 1'-6" GR-E GR-A A4a 6'-10" F4a 2'-11 7/8" 3'-0"1'-4" A4a F4a F1a6 3/4" MIN 4'-11"23.3 26.3 22.6 8.16 A501 1CA002b 4A 22.9 QQARI 235 TA-7 TA-23 TA-21 TA-1 TA-3 TA-17 BED-103 BED-103 BED-104.1 BED-104.1 BED-104 BED-104 BED-105 BED-105 UPH-100 UPH-100.1 LTG-102 ART-100 EQU-100 CSG-100* WTR-100 & WTR-101 CSG-104 CSG-104 ART-101 ART-102 MIR-100 CSG-118R TA-19 TA-17 TA-2 MIR-202 BACKLIT, COORD. W/ ELEC. 10.1 ART-200 TA-24 MIR-203 10.3 TA-26 9 LTG-101 QQARI 235 ALIGNT-01 T-02 W PNT-008 F CPT-100 C PNT-001 B VB-001 W WD-001 W VWC-200 F CT-001 C PNT-001 B CTB-001 F CT-001 B VB-001 9.2 W SRD-001 QQARI 235 2.4 2.3 2.15 2.16 2.17 2.43 2.22 2.14 2.25 2.1 2.7 2.5 2.19 2.30 2.3 2.4 2.43 2.70 2.73 2.70 2.87 B CTB-001 W VWC-200 TA-23 4'-2"10" B CTB-001 W VWC-200 W SRD-001T PNT-002 4'-0" MAXCLEQ EQ EQ2 EQ2 W SRD-001 4'-0" MAX AFFCL8" TA-26 9 B CTB-001 W VWC-200 W SRD-001 REMOVABLE PANEL TO B.O. REFLECTIVE SURFACE3'-4" MAX2C A501 4'-9"B VB-001 W PNT-008 WTR-100 & WTR-101 B VB-001 W PNT-008 MIR-100 WTR-100VAL WTR-100 & WTR-101 6"1'-7"CL B VB-001 W PNT-008 T PNT-002 CL2'-2" EQ 4'-6"CL EQ W WD-001W PNT-008 B VB-001 7'-8" 5'-6"5'-0"NOTE: WALL SCONCE SHOULD BE MOUNTED SO ROCKER SWITCH IS LOCATED 40" AFF. QQARI 235 C EXIST 6' - 11" A.F.F. MATCH ADJACENT 9.6 9.6 26.7 26.7 + -+ - + - 26.7 9.6 C PNT-001 7' - 0" AFF C PNT-001 7' - 0" AFF C PNT-001 8' - 0" AFF A500 6BSIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:35:13 PMENLARGED ACCESSIBLE GUESTROOM PLANS - QQARI (ROOM 235) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A434 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.73 REMOVE SHELF. 2.87 REMOVE ROLL IN SHOWER. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.9 PROVIDE 1-PIECE ADA-COMPLIANT ROLL-IN SHOWER W/ SEAT, GRAB BARS, CONTROLS, CURTAIN & ROD. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN - QQARI SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - QQARI SCALE: 1/4" = 1'-0"4A FINISH PLAN - QQARI SCALE: 1/4" = 1'-0" DRAWING REF: D112 2A DEMOLITION PLAN - QQARI SCALE: 1/4" = 1'-0" DRAWING REF: A4342CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A434 3C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4344CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4345CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4342BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A434 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A434 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A434 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - QQARI 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 QA 306 22.4 8.1 23.2 23.1 8.8 8.9 23.3 4.1 8.6 8.7 27.1 A435 2B 4B 5B 6B A435 2C 3C 4C 5C 8.18 26.6 22.8 GR-E GR-A F1a A4a MIN 1'-6"1'-8" 5'-0 1/4" 1'-4"3'-0"3'-0" 3'-0" F4a F4a 3 1/8" 5'-0" 22.5 22.6 26.3 8.16 A501 1C A002b 4B QA 306 TA-7 TA-1 TA-23 TA-2 TA-17 ART-102ART-101 LTG-100 CSG-100* CSG-104 EQU-100 ART-100 LTG-102 UPH-100 UPH-100.1 WTR-100 & WTR-101 LTG-101 CSG-100* BED-103 BED-104.1 BED-104 BED-105 MIR-100 CSG-118R MIR-202 BACKLIT, COORD. W/ ELEC. 10.1 TA-23 ART-200 UPH-115 TA-24 MIR-203 10.3 TA-21 TA-19 TA-17 TA-6 9 QA 306 ALIGN T-01 T-02 F CT-001 W VWC-200 B CTB-001 F CT-001 C PNT-001 B VB-001 F CPT-100 C PNT-001 W PNT-008 B VB-001 W WD-001 9.2 W SRD-001 QA 306 2.3 2.4 2.15 2.16 2.17 2.43 2.14 2.222.25 2.30 2.19 2.5 2.71 2.9 2.3 2.4 2.43 2.1 2.75 2.70 2.70 2.73 2.70 2.70 2.70 2.7 QA 306 C EXIST 6' - 10 1/4" A.F.F. C GYP 6' - 10" A.F.F. 9.6 26.7 2.26 26.7 26.7 + -EQ EQEQ EQ C PNT-001 8' - 0" AFF C PNT-001 7' - 0" AFF C PNT-001 7' - 0" AFF + - + - C PNT-001 7' - 2 1/2" A.F.F. A500 6B SIM B VB-001 W PNT-008 WTR-100 & WTR-101 W PNT-008 W WD-001 B VB-001 LTG-101 CL4'-6"CLCL 3'-9" 6'-5 1/4" NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. B VB-001 W PNT-008 ART-101 ART-102 4'-6"2'-2" CL EQ CL EQ B VB-001 W PNT-008 CL4'-6"CL 3'-0" ART-100 MIR-100 WTR-100 & WTR-101 CL 7'-8"6"B CTB-001 W VWC-200 4'-0" MAX AFFCL8"WSRD-001 B CTB-001 W VWC-200W SRD-001 T PNT-002 4'-0" MAXCLEQ EQ EQ2 EQ2 B CTB-001 W VWC-200 TA-23 4'-2"10" B CTB-001 W VWC-200 W SRD-001 REMOVABLE PANEL TO B.O. REFLECTIVE SURFACE3'-4" MAX2C A501 4'-9"1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:35:29 PMENLARGED ACCESSIBLE GUESTROOM PLANS - QA (ROOM 306) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A435 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.71 REMOVE WC. 2.73 REMOVE SHELF. 2.75 ACCESSIBLE LOOP TYPE WINDOW PULLS TO BE SALVAGED AND REINSTALLED. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND DIVERTER. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -QA SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - QA SCALE: 1/4" = 1'-0"4A FINISH PLAN - QA SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN -QA SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - QA SCALE: 1/4" = 1'-0" DRAWING REF: A4352BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A435 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A435 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A435 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4352CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4353CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4354CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4355CELEVATION - BATHROOM 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 QA 406 23.2 8.10 23.3 23.1 8.1 4.1 8.6 8.7 27.1 A436 2C 3C 4C 5C A436 2B 4B 5B 6B 22.6 22.4 GR-E GR-A A4a 1'-4"3'-0" F4a F4a F4a 5'-0" MIN 1'-6" 26.3 26.6 22.8 8.18 8.16 8.8 A002b 4B 3'-0" 2'-9"10" + - MAINT. MAX. ALLOWABLE DEPTH. 9 QA 406 2.3 2.1 2.7 2.4 2.15 2.16 2.17 2.25 2.30 2.22 2.43 2.19 2.9 2.71 2.5 2.3 2.4 2.43 2.732.70 2.70 2.70 QA 406 TA-7 TA-23 TA-1 TA-17 TA-3 BED-103 BED-104 BED-104.1 BED-105 EQU-100 ART-100 LTG-102UPH-100 UPH-100.1 LTG-101 WTR-103 WTR-102 LTG-100 CSG-100* ART-101 ART-102 MIR-100CL CL6'-3"3'-9 1/2" CLCL 10'-1 1/2" 2'-7"CSG-104 CSG-118R11 1/4"CSG-100* MIR-202 BACKLIT, COORD. W/ ELEC. 10.1 ART-200 UPH-115 MIR-203 10.3 TA-21 TA-17 TA-19 TA-6 9 WS BATH COLLECTIONS MODEL: UNLIMITED 60 9 QA 406 ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-008 B VB-001 C PNT-001 F CT-001 W VWC-200 B CTB-001 W WD-001 F CT-001 B VB-001 W SRD-001 5/8" 9.2 QA 406 C GYP 7' - 0" A.F.F. C EXIST 7' - 4 1/4" A.F.F. C EXIST 6' - 9" A.F.F. C EXIST 6' - 8 1/2" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C GYP 7' - 0" A.F.F. 9.6 26.7 2.26 C GYP 6' - 10" A.F.F. 26.7 26.7 PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 A500 6B SIM W SRD-001 B CTB-001 W VWC-200W SRD-001 T PNT-002 4'-0" MAXCLEQ EQ EQ EQ B CTB-001 W VWC-200 TA-23 4'-2"10" 9 B CTB-001 W VWC-200 W SRD-001 TO B.O. REFLECTIVE SURFACE3'-4" MAX4'-9"2'-10"9 B VB-001 W PNT-008 WTR-103 WTR-102 W WD-001 W PNT-008 CLCL 3'-9 1/2" CSG-104 10'-0 1/2" B VB-001 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. LTG-101 W PNT-008 CLCL EQ 2'-2" B VB-001 CL4'-6"B VB-001 W PNT-008 MIR-100 ART-100 LTG-102 CL4'-6"CL 2'-7" CL 8'-11"6"1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:35:43 PMENLARGED ACCESSIBLE GUESTROOM PLANS - QA (ROOM 406) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A436 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.71 REMOVE WC. 2.73 REMOVE SHELF. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.6 PROVIDE WC. 22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND DIVERTER. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A113 3A CONSTRUCTION PLAN -QA SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -QA SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - QA SCALE: 1/4" = 1'-0"4AFINISH PLAN - QA SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - QA SCALE: 1/4" = 1'-0" DRAWING REF: A4362CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4363CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A436 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4365CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4362BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A114 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A436 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A436 4B ELEVATION 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 UP DWREF.DWREF.DWREF.DW REF. A437a 5B 6B 2C 5D A437a 1B 2B 3B 4B A437a 3C 4C 5C 6C GR-E GR-A15'-6"8.1 4.1 8.6 8.7 27.1 26.6 8.108.10 23.2 23.3 23.3 22.8 23.1 22.6 A4a A4a GR-S 3'-0" 3'-0" 1'-8 1/4" 5'-0" 1'-4" MIN 1'-6"2'-9"MIN1'-0"1'-4"A4a GR-Da F2a F3a F4a A500 1C 22.5 8.18 13.1 22.8 26.3 8.1 8.6 8.7 8.16 8.1627.1 8.88.8 8.5 4.1 A501 1C A002b 4B 22.4 A437a 3D QA 422 KCONAL 424 A501 2A SIM 3'-0" MIN GR-C 9 2.3 2.4 2.15 2.3 2.16 2.4 2.17 2.43 2.15 2.16 2.17 2.43 2.3 2.4 2.43 2.5 2.30 2.9 2.19 2.1 2.1 2.72.7 2.22 2.20 2.22 2.78 2.71 QA 422 KCONAL 424 2.2 2.30 9 T-02 C PNT-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B VB-001 F CPT-100 C PNT-001 W PNT-008 B VB-001 W WD-001 ALIGN T-01F CPT-100 C PNT-001 W PNT-003 B VB-001 W SRD-001 F CT-001 C PNT-001 W PNT-003 B VB-001 W CT-002 9.2 9.2 CL1'-4"T-02 T-01 ALIGN QA 422 KCONAL 424 KCONL 412 TA-7 TA-23 TA-1TA-2 TA-17 UPH-105.2 UPH-105 UPH-105.1 CSG-104 WTR-102 WTR-103 EQU-101.1 CSG-113 ART-104WTR-103 WTR-102 MIR-100 BED-105 BED-104 CSG-100* BED-103 LTG-102 ART-100 EQU-101.1 UPH-114 CSG-120 UPH-114 UPH-110 CSG-108 MIR-202 LTG-101 BACKLIT, COORD. W/ ELEC. ART-200 TA-24 MIR-203 10.3 LTG-104LTG-104 10.1 ART-102 ART-101 QA 422 KCONAL 424 TA-19 TA-17 TA-21 TA-6 9 9 C EXIST 7' - 4" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXISTING C GYP 6' - 10" A.F.F. C GYP 6' - 10" A.F.F. + - + - 2.26 2.26 9.6 9.6 9.6 26.7 26.7 26.7 2.77 C GYP 7' - 0" A.F.F. C GYP 7' - 0" A.F.F. 26.7 26.7 PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 PNT-001 CL 1'-9 1/2" CLEQEQ CLEQ EQCL 2'-0" QA 422 KCONAL 424 9.25 OPEN 9 W SRD-001 4'-0" MAX AFFCL9" B CTB-001 W SRD-001 W VWC-200 4'-0" MAXCLEQ EQ EQ2 EQ2 B CTB-001 W VWC-200 TA-23 4'-2"10" B CTB-001 W SRD-001 W VWC-200 REMOVABLE PANEL TO B.O. REFLECTIVE SURFACE3'-4" MAX2C A501 4'-9"B VB-001 W PNT-008 B VB-001 W WD-001 CL 77"60"W PNT-0082'-3"6"NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. B VB-001 T PNT-002 B VB-001 W PNT-008 T PNT-002 W PNT-008 B VB-001 W PNT-003 72"ART CL B VB-001 W PNT-003 T PNT-002 W PNT-003 B EXIST B VB-001 W PNT-003 T PNT-002 4E A122 B VB-001 W PNT-003 T PNT-002 ACCESS DOOR A501 6C SIM CL5'-0"CL 1'-6" CL1'-6" W PNT-003 B VB-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:35:49 PMENLARGED ACCESSIBLE GUESTROOM PLANS - KCONAL (ROOM 424) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A437a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 8.18 PROVIDE SECURITY LATCH AT 48" AFF. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.8 PROVIDE TUB, ACCESSIBLE CONTROLS, DIVERTER, SHOWERHEAD AND DIVERTER. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.71 REMOVE WC. 2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT BULB. 2.78 REMOVE STAIR AND RAILINGS. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN - KCONAL SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN - KCONAL SCALE: 1/4" = 1'-0"4A FINISH PLAN - KCONAL SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KCONAL SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KCONAL SCALE: 1/4" = 1'-0" DRAWING REF: A437a3CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437a4CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437a5CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437a 6C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437a1BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a 2B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A114 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a2CELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437a 5D ELEVATION T PNT-002 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A437a3DELEVATION 9 9 9 9 99 9 9 9 99 9 9 9 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 9 99 08/02/2017 01/11/18 DN DN OPEN TA-20 TA-23 TA-21 TA-22 TA-16 TA-18 TA-7 EQ EQ MIR-200 UPH-100 UPH-100.1 ART-100 CSG-101 LTG-101 CSG-100* BED-102 BED-100 BED-101 BED-101.1 ART-105 LTG-100 CSG-100* CSG-119R LTG-102 MIR-100 3'-0"B.O. MIRROR AT 6" AFF ART-200 TA-25 MIR-2031'-0"10.3 CL EQU-100 KCONL+ 524 F CPT-100 C PNT-001 C PNT-001 W PNT-003 B VB-001 W WD-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B VB-001 W SRD-001 W CT-002 ALIGN T-01 OPEN 9.2 KCONL+ 524 2.3 2.4 2.15 2.16 2.17 2.43 2.3 2.4 2.43 2.9 2.5 OPEN 2.78 2.19 2.30 KCONL+ 524 A437a 4B OPEN GR-BR 23.3 23.1 22.5 A437b 2B 4B 5B 6B A437b 4C 5C 2C A437b 6C 26.6 26.6 6.2 13.1 13.1 GR-Db A500 1D A4a 26.3A500 2A A002b 4C 2D A437a 3D 22.1 KCONL+ 524 6'-0"CL2'-0" MIN CLRALIGN A501 2A SIM 1'-0" EXIST. AC UNIT 9 B VB-001 W PNT-003 NOTE: SHIFT DOOR LOCATION DEPENDING ON HVAC LOCATION WITHIN CLOSET. HVAC LEFT/DOOR RIGHT HVAC RIGHT/DOOR LEFT B VB-001 W WD-001 6'-9 1/8" 4'-4 1/2" NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. B VB-001 W PNT-003 5'-0"CLEQ EQ 9 B CTB-001 CL B VB-001 W PNT-003 3'-6"8 1/2" 3'-10"ENCLOSE AC REGRIDGERANT PIPES, 3/4" PLYWOOD PAINTED B CTB-001 W CT-002 3'-4"4'-6"4'-2"B CTB-001 W VWC-200 4'-0"CL1'-4" B CTB-001 W SRD-001 W VWC-200 4'-9"W SRD-001 KCONL+ 524 C PNT-001 C PNT-001 C EXIST C EXIST 9.25 7' - 0" A.F.F +- OPEN 9 5'-0"EQ 1'-2" EQ SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KCON LOFT SCALE: 1/4" = 1'-0"4A FINISH PLAN - KCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -KCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF:A1133ACONSTRUCTION PLAN -KCON LOFT KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.78 REMOVE STAIR AND RAILINGS. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: A437b2BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437b 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437b 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437b 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A437b 6C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437b2CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437b 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A437b5CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A5016AREFLECTED CEILING PLAN - KCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF:A437b2DKCONLOFT - BATH EAST ELEV 9 9 9 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:35:53 PMENLARGED GUESTROOM PLANS - KCONL LOFT (ROOM 524) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A437b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 99 9 9 9 08/02/2017 01/11/18 REFK1L 208 A4415B A441 2C 4B 2B 3C 4C 5C 22.5 22.127.1 26.3 8.1 26.6 26.4 8.16 8.6 8.7 23.1 8.8 A441 3B 23.2 8.9 23.3 GR-A HARDWARE #1 4.1 8.5 A500 2A A002b 4C A501 4D SK-1 1 9 LTG-100 LTG-101 TA-7 TA-20 TA-13 WTR-100 & WTR-101 TA-22 TA-18 TA-16 TA-21 BED-100 BED-101 BED-101.1 BED-102 CSG-100 CSG-100 CSG-101 UPH-100 UPH-100.1 ART-100 EQU-101.1 CSG-102 MIR-100 LTG-103 UPH-102 UPH-102.2 UPH-102.3 UPH-102.1 ART-102 ART-101 MIR-200 EQU-102 CLCL 4'-6 1/2" 4'-5 1/4"CLCL 9'-0" 4'-0"A500 2A A500 3A ART-200 MIR-203 10.3 10.1 LTG-102 9 15'-3 1/2"6'-4 1/2" 15'-3 1/2"K1L 2089.2 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001 W WD-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B CTB-001 W SRD-001 W CT-002 ALIGN T-01 T-02 9 K1L 208 2.3 2.3 2.30 2.5 2.1 2.9 2.7 2.17 2.14 2.15 2.16 2.19 2.22 2.25 2.4 2.43 2.4 2.43 2.70 B VB-001 W PNT-008 B CTB-001 W PNT-008 W WD-002 CL54"CLCL 107 7/8" 48" MIR-100 1'-0"B VB-001 W PNT-008 WTR-100 & WTR-101 T PNT-002 W PNT-008 CL60"CL 26" W WD-002 B VB-001 CLEQ B CTB-001 W CT-002 MIR-200CL 5'-0"CLEQ EQ B CTB-001 W VWC-200 W SRD-001 CL6 1/2" 4'-6"CLCL1'-10"CL1'-0" CL 4'-9"W SRD-001 W VWC-200 T PNT-002 W SRD-001 5'-0"EQ 1'-6" EQ 4'-2"10" K1L 208 2.26 26.5 26.7 9.6 9.6 C EXIST 8' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C GYP 6' - 10" A.F.F. 26.7 9.6 26.7 + -+ - + - PNT-001 PNT-001 PNT-001 A500 6B SIM B CTB-001 W PNT-008 W WD-001 T PNT-002 B VB-001 CL77" 52" W WD-002 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:36:05 PMENLARGED GUESTROOM PLANS - K1L (ROOM 208) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A441 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.4 INSTALL SAFE AND PLACE ON CLOSET SHELF. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -K1L SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - K1L SCALE: 1/4" = 1'-0"4A FINISH PLAN - K1L SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN -K1L SCALE: 1/4" = 1'-0" DRAWING REF: 1 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 12BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 1 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 12CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 13CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 14CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 15CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - K1L SCALE: 1/4" = 1'-0" DRAWING REF: 1 3B ELEVATION 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. 9 9 99 9 9 99 9 9 08/02/2017 01/11/18 5'-0" 7" 2'-0 1/2"18'-2"5'-7 3/4" 6'-3" 2"8"24'-8 1/2"QQ1L 205 9.2 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001 W WD-001 F CT-001 W VWC-200 B CTB-001 F CT-001 B CTB-001 W CT-002 ALIGN T-01 T-02 1'-5 1/2"1'-6" 1'-6" 1'-6"7 1/4"W SRD-001 9 TA-7 TA-18 TA-21 TA-13 TA-19 TA-16 1'-0" 1'-1"MIR-200 BED-103 BED-103 BED-104 BED-104 BED-104.1 BED-104.1 BED-105 BED-105 CSG-100 UPH-102.3 UPH-102.2 UPH-102.1 ART-102 ART-101 UPH-102 LTG-103 CSG-107 EQU-100 CSG-105 LTG-102 ART-100 UPH-100 UPH-100.1 WTR-102 & WTR-103 CSG-104 CSG-104 CL CL 5'-4" 8'-11"MIR-100 2'-5" A500 3A A500 5A ART-200 MIR-203 10.3 9 LTG-101 QQ1L 205 A442 2B 3B 4B 6B A442 2C 3C 4C 5C 22.5 22.4 22.7 8.1 4.1 26.3 27.1 26.623.1 8.16 8.7 8.6 8.8 8.10 23.2 22.6 GR-A HARDWARE #1 8.5 23.3 A500 2A A002b 4D A501 4D 9 22.2 QQ1L 205 2.5 2.30 2.1 2.3 2.17 2.7 2.3 2.13 2.15 2.16 2.14 2.19 2.22 2.25 2.4 2.43 2.4 2.43 2.70 B VB-001 W PNT-008 WTR-102 & WTR-103 W WD-001 B CTB-001 W PNT-008 T PNT-002 W PNT-008 B VB-001 CLCL 89" 73"CL36" AFFW WD-002NOTE: WALL SCONCE SHOULD BE MOUNTED SO ROCKER SWITCH IS LOCATED 40" AFF. T PNT-002 W PNT-008 CL26" EQ ART-102 ART-101 CL60"B VB-001 W WD-002 CLEQW PNT-008 B VB-001 W PNT-008 B CTB-001 W WD-002 MIR-100 ART-100 WTR-100VAL WTR-102 & WTR-103CL 54"CLCL 107" 64"6"B CTB-001 W CT-002 MIR-200 CL EQEQ CL5'-0"B CTB-001 W VWC-200 W SRD-001 CLEQ EQ 4'-6" CLCL1'-10"4'-9"W SRD-001W VWC-200 W SRD-001 B CTB-001 T PNT-002 11"4'-2"5'-0"EQ 1'-6" EQ QQ1L 205 2.26 26.7 26.7 26.5 9.6 9.6 C GYP 6' - 10" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 4" A.F.F. 9.6 26.7 MATCH ADJACENT + - + - + - PNT-001 PNT-001 PNT-001 PNT-001 A500 6B SIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:36:16 PMENLARGED GUESTROOM PLANS - QQ1L (RM 205) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A442 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.13 REMOVE TUB/SHOWER SURROUND. TUB/SHOWER TO REMAIN. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0"4AFINISH PLAN - QQIL SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - QQIL SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -QQ1L SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN - QQIL SCALE: 1/4" = 1'-0" DRAWING REF: 22BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 2 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 2 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 2 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 22CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 23CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 24CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: 25CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - QQIL 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 REFKSR 301 4A A501 2.14 2.3 2.22 2.16 2.25 2.15 2.19 2.5 2.9 2.30 2.1 2.7 2.3 2.43 2.4 2.4 2.17 2.43 KSR 301 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001 W WD-001 W VWC-200 F CT-001 B CTB-001 W CT-002 ALIGN T-01 T-02 4A A501 9.2 W SRD-001 16'-0 1/2" KSR 301 A443 2C 3C 4C 5C A443 2B 3B 4B 6B 4A A501 8.8 23.2 26.3 22.5 26.6 27.1 8.1 8.7 8.5 8.6 26.6 8.9 23.3 GR-A HARDWARE #1 4.1 8.16 A500 2A A002b 4C 22.1 A501 4D GR-Dc KSR 301 TA-7 TA-20 TA-13 TA-21 TA-22 TA-18 TA-16 LTG-100 LTG-101 WTR-100 & WTR-101 ON SHELF BED-100 BED-101 BED-101.1 BED-102 MIR-100 CSG-100* CSG-100* EQU-101.1 UPH-102.2 UPH-102.3 UPH-102.1 ART-101 ART-102 UPH-103 LTG-103 CSG-107 CSG-102 ART-100 LTG-102 UPH-100 UPH-100.1 MIR-200 EQU-102 CL EQ EQ CSG-101 CL CL4'-6"4'-9 1/2"CLCL 10'-8" 3'-0"A500 3A A500 5A ART-200 MIR-203 10.3 10.1 4A A501 B CTB-001 W CT-002 MIR-200CL 60"CL EQEQ B CTB-001 W VWC-200 W SRD-001 4'-2"1'-0"5'-0"EQ 1'-6" EQ 4A A501 W SRD-001 B CTB-001 W VWC-200 W SRD-001 TA-13 CLEQEQ 4'-6"CLCL 1'-10" 4'-9"4A A501 B VB-001 W PNT-008 WTR-100 & WTR-101 W PNT-008 B VB-001 BCTB-001 W PNT-008 W WD-002 MIR-100 ART-100 CLCL36" 128"CL54"4A A501 W PNT-008 B VB-001 CLCL EQ 26" EQ ART-101 ART-102 CL60"B CTB-001 W WD-001 W PNT-008 B VB-001 CSG-101 LTG-101 WTR-100 & WTR-101 5'-0"CLCL 4'-9 1/2" 4'-6" B CTB-001 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. KSR 301 C GYP 7' - 0" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C GYP 6' - 10" A.F.F. 9.6 9.6 9.6 26.7 26.7 26.7 2.26 26.5 C EXIST 7' - 1 1/2" A.F.F. MATCH ADJACENT + - + - + - PNT-001 PNT-001 PNT-001 PNT-001 A500 6B SIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:36:28 PMENLARGED GUESTROOM PLANS - KS (ROOM 301) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A443 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN -KS SCALE: 1/4" = 1'-0"4AFINISH PLAN - KS SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -KS SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KS SCALE: 1/4" = 1'-0" DRAWING REF: A4432CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4433CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4434CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A443 5C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4432BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A443 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A443 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A443 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - KS 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 9 9 9 9 08/02/2017 01/11/18 REFKEXR 4398.10 8.10 8.8 26.3 26.6 26.6 23.3 23.2 23.1 22.5 27.1 8.1 8.7 8.5 8.6A444 2C 3C 4C 5C A444 2B 3B 4B 6B GR-A HARDWARE #1 8.16 4.1 8.8 A500 2A A002b 4C 22.1 9 KEXR 439 2.22 2.3 2.15 2.16 2.22 2.14 2.25 2.1 2.7 2.19 2.5 2.302.30 2.9 2.17 2.43 2.4 2.3 2.4 2.43 KEXR 439 TA-7 TA-20 TA-13 TA-21 TA-22 TA-18 TA-16 WTR-103 LTG-100 LTG-101 WTR-102 CSG-100* CSG-100* MIR-100 CL CL CL2'-6"4'-5 3/4" 7'-11 1/4" MIR-200 UPH-102.1 UPH-102.2 UPH-102.3 UPH-102 ART-102 ART-101 LTG-103 CSG-107 EQU-101.1 CSG-102 LTG-102 ART-100 UPH-100 UPH-100.1CL 2'-7"CSG-101BED-100 BED-101 BED-101.1 BED-102WTR-100 & WTR-101 A500 3A A500 5A ART-200 MIR-203 10.3 10.1 9 KEXR 439 F CPT-100 C PNT-001 C PNT-001 W PNT-008 B VB-001 W WD-001 W VWC-200 F CT-001 B CTB-001 W CT-002 ALIGN T-01 T-02W SRD-001 9.2 F CT-001 B CTB-001 9 W SRD-001 B CTB-001 W VWC-200 W SRD-001 CLEQEQ 4'-6" CLCL1'-10"4'-9"B CTB-001 W CT-002 MIR-200CL 5'-0"CL EQEQ B CTB-001 W VWC-200 W SRD-001 T PNT-002 4'-2"1'-0"5'-0"EQ 1'-6" EQ W PNT-008 B VB-001 CL CL26"23" ART-101 ART-102CL 60" AFFW PNT-008 W WD-002 W WD-001 B VB-001B CTB-001 CLCL 54" 94 7/8" LTG-101 WTR-100VAL WTR-102 WTR-103 60" AFFNOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40"AFF. W PNT-008 WTR-100VAL WTR-102 WTR-103 T PNT-002 W PNT-008 B VB-001 B CTB-001 W PNT-008 ART-100 CL4'-6"CL 2'-7" WTR-100 & WTR-101 C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 6" A.F.F. C EXIST 7' - 0" A.F.F. C GYP 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. KEXR 439 MATCH ADJACENT 9.6 9.6 9.6 26.7 26.7 26.7 26.5 2.26 + - + - + - + - PNT-001 PNT-001 PNT-001 A500 6B SIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:36:40 PMENLARGED GUESTROOM PLANS - KEX (ROOM 439) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A444 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -KEX SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN - KEX SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KEX SCALE: 1/4" = 1'-0"4A FINISH PLAN - KEX SCALE: 1/4" = 1'-0" DRAWING REF: A4442CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4445CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4444CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A444 3C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4442BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A444 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A444 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A444 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KEX 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 9 9 9 99 08/02/2017 01/11/18 REFKEX 439 12.4 8.10 8.10 8.8 26.3 10.1 26.6 26.6 23.3 23.2 23.1 22.5 22.1 27.1 8.1 8.7 8.5 8.6A445 2C 3C 4C 5C A445 2B 3B 4B 6B GR-A HARDWARE #1 8.16 4.1 8.8 KEX 439 2.22 2.3 2.15 2.16 2.22 2.14 2.25 2.1 2.7 2.19 2.5 2.302.30 2.9 2.17 2.43 2.4 2.3 2.4 2.43 KEX 439 TA-7 TA-20 TA-23 TA-21 TA-22 TA-18 TA-16 WTR-103 LTG-100 LTG-101 WTR-102 CSG-100 CSG-100 MIR-100 CL CL CL2'-6"4'-5 3/4" 7'-11 1/4" MIR-200 UPH-102.1 UPH-102.2 UPH-102.3 UPH-102 ART-102 ART-101 LTG-103 CSG-107 EQU-101.1 CSG-102 LTG-102 ART-100 UPH-100 UPH-100.1CL 2'-7"CLCL 1'-11" 2'-2" 1'-11" CSG-101BED-100 BED-101 BED-101.1 BED-102 BED-106WTR-100 & WTR-101 KEX 439 F CPT-100 C PNT-001 C PNT-001 W PNT-003 B VB-001 W WD-001 W VWC-200 F CT-001 B CTB-001 W CT-002 ALIGN T-01 T-02W SRD-001 9.2 F CT-001 B CTB-001 W SRD-001 B CTB-001 W VWC-200 W SRD-001 B CTB-001 W CT-002 MIR-200CL 5'-0"CL EQEQ B CTB-001 W VWC-200 W SRD-001 T PNT-002 W PNT-003 B VB-001 CL CL26"23" ART-101 ART-102CL 60" AFF50" AFFW PNT-003 W WD-002 W PNT-003 B VB-001B CTB-001 CLCL 54" 94 7/8" LTG-101 WTR-100VAL WTR-102 WTR-103 60" AFFW PNT-003 WTR-100VAL WTR-102 WTR-103 T PNT-002 W WD-001 B VB-001 B CTB-001 W PNT-003 ART-100 CL4'-6"CL2'-7" WTR-100VAL WTR-100 & WTR-101 C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 6" A.F.F. C EXIST 7' - 0" A.F.F. C GYP 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. KEX 439 MATCH ADJACENT 2.77 2.77 2.77 9.6 9.6 9.6 26.7 26.7 26.7 26.5 2.26 + - + - + - + - 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2014 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:12:15 PMENLARGED GUESTROOM PLANS - KING EXEC THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A445 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT BULB. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH HORIZONTAL PIECE TO SIZE. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION -KING EXEC SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMO PLAN - KING EXEC SCALE: 1/4" = 1'-0"5AFF& E -KING EXEC SCALE: 1/4" = 1'-0"4A FINISH PLAN - KING EXEC SCALE: 1/4" = 1'-0" DRAWING REF: A4452CBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445 5C BATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445 4C BATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4453CBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4452BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A123 6ARCP -KING EXEC ROOM TYPE FURNITURE MARK FURNITURE COUNT KEX ART-100 1 ART-101 1 ART-102 1 BED-100 1 BED-101 1 BED-101.1 1 BED-102 1 BED-106 1 CSG-100 2 CSG-101 1 CSG-102 1 CSG-107 1 EQU-101.1 1 LTG-100 1 LTG-101 1 LTG-102 1 LTG-103 1 MIR-100 1 MIR-200 1 UPH-100 1 UPH-100.1 1 UPH-102 1 UPH-102.1 1 UPH-102.2 1 UPH-102.3 1 WTR-100 & WTR-101 1 WTR-100VAL 2 WTR-102 1 WTR-103 1 ROOM TYPE FURNITURE COUNT KEX 1 1 08/25/2016 Revision 1 01/11/18 DWREF.DWREF. DWREF.DWREF. KKCON 405 2.19 2.1 2.22 2.7 2.3 2.4 2.15 2.16 2.17 2.43 2.37 2.3 2.4 2.43 2.1 KKCON 405 TA-18 TA-23 WTR-103 WTR-102 UPH-106.1 UPH-106 CSG-112 UPH-105 UPH-105.2 UPH-105.1 CSG-113 UPH-108UPH-108 EQU-103 UPH-108 MIR-202 ART-200 ART-105 9 KKCON 405 ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W PNT-003 F CT-001 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 9.2 9 KKCON 405 A445a 4B 3'-11"8.1 8.5 8.6 8.7 8.16 4.1 27.1 26.6 26.63.3 13.1 8.10 8.8 23.3 HARDWARE #2 HARDWARE #1 9.22 23.1 GR-S A445a 2C 3C 4C A445a 2D 3B 2B 6B 2.20 5'-5 1/2" 1'-1"5C A445a 1" 3D4D A445b 4D A501 2A SIM 9 KKCON 405 C EXIST 7' - 0" A.F.F. + - + - C EXIST 7' - 0" A.F.F. C GYP 7' - 0" A.F.F. 2.6 9.6 26.7 2.6 9.6 26.7 2.26 PNT-001 PNT-001PNT-001 A500 6B SIM C EXIST OPEN 9.25 9 W PNT-003 B VB-001 CL2'-9"6"W PNT-003 B VB-001 T PNT-002 A501 6C SIM 9 W PNT-003 B VB-001 A445a 5C CL 8'-2"5'-0"T PNT-002 W PNT-003 B VB-001 T PNT-002 T PNT-002 W PNT-003 B VB-001 B CTB-001 W VWC-200 TA-23 TA-18 4'-9"W PNT-003 W PNT-003 B VB-001 3'-1 1/2"1 1/2"3 1/2" 8 1/2" 3/4" MARINE GRADE PLYWOOD SECURED TO BAR DIE WALL EXISTING WALL STONE COUNTER (STN-002) WALL BEYOND W VWC-200 T-23 B CTB-0011'-10"CL 8"4'-0"CLT-18 CL1'-0" W VWC-200 B CTB-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:36:54 PMENLARGED GUESTROOM PLANS - KKCON (ROOM 405) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A445a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1132ADEMOLITION PLAN - KKCON KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.6 REMOVE CEILING MOUNTED LIGHT FIXTURES. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 3.3 PATCH FLOOR WHERE SPIRAL STAIR WAS REMOVED. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.22 PROVIDE STONE TOP ON 3/4" PLYWOOD. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1135AFURNITURE PLAN - KKCON SCALE: 1/4" = 1'-0" DRAWING REF: A1134AFINISH PLAN - KKCON SCALE: 1/4" = 1'-0" DRAWING REF: A113 3A CONSTRUCTION PLAN - KKCON SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KKCON SCALE: 1/4" = 1'-0" DRAWING REF: A445a 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445a 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445a 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445a2BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445a2CELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A445a2DELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445a 3C ELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A445a 4C ELEVATION - KITCHEN 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 3/4" = 1'-0" DRAWING REF: A445a5CSECTION - KITCHEN COUNTER SCALE: 1/4" = 1'-0" DRAWING REF: A445a3DELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445a4DELEVATION - BATHROOM EQU-103.1 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 KKCON+ 505 2.51 2.37 2.72 2.30 2.5 2.19 2.3 2.4 2.43 2.9 2.3 2.4 2.15 2.16 2.17 2.18 2.43 OPEN A445b 5D KKCON+ 505 OPEN ALIGN T-01 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 W WD-001 W CT-002 W SRD-001 KKCON+ 505 OPEN TA-18 TA-7 TA-20 TA-23 TA-21 TA-22 TA-16 MIR-200 CSG-102 UPH-100 LTG-102 ART-100 ART-200 TA-25 EQU-103 CSG-111MIR-100 CLEQ EQART-102 ART-101 EQU-103.1 BED-100 BED-101 BED-101.1 BED-102 BED-100 BED-101 BED-101.1 BED-102 LTG-101 CSG-100* KKCON+ 505 OPEN 2'-3 1/2" 6'-7 1/2"GR-A 22.5 23.1 26.6 26.6 3.1 26.6 6.2 13.1 GR-Db 7'-3" A500 1D A445b 2B 4B 5B 6B A445b 2C 3C 4C 5C EQ EQ A500 2A CL3'-2"A445b 3D 2D A002b 4C 4D 22.1 A501 2A SIM 3'-0"CL5'-0"CL CL3'-0"4'-3" B VB-001 W PNT-003W WD-001 B VB-001 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT THE ROCKER SWITCH IS LOCATED 40" AFF. W WD-001 CL4'-6"CL2'-2 1/2" B VB-001 W PNT-003 4'-9" CL 5'-6" W PNT-003 B VB-001 W SRD-001 B CTB-001 W VWC-200W SRD-001 TA-23 4'-9"B CTB-001 W VWC-200 T-23 1'-10"CL8"4'-0"CL1'-4" TA-25 B CTB-001 W SRD-001T PNT-002 5'-0"EQ1'-6" EQ TA-18 3'-6"CL EQEQ 7'-6"W PNT-003 W CT-002 B CTB-0014'-0"CL 3'-2" TA-18 6"B CTB-001 B VB-001 W PNT-003 W VWC-200 4'-2"W VWC-200 B CTB-001 C EXIST 7' - 0" A.F.F. C EXIST OPEN 9.25 C PNT-001 C PNT-001 EXISTING PERIMETER FRAMING (2) 2 X 10 EQ EQ EQ2 X 10 TIED INTO PERIMETER FRAMING 4'-2"1 A 2 3 4 5 6A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:37:08 PMENLARGED GUESTROOM PLANS - KKCON LOFT (ROOM 505) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A445b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1132ADEMOLITION PLAN - KKCON LOFT KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.18 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.51 REMOVE RAILING. 2.72 REMOVE FLOOR SLAB. 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: A1134AFINISH PLAN - KKCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1135AFURNITURE PLAN - KKCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN - KKCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A0032BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445b 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A003 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445b 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A445b2CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445b3CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445b4CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445b5CELEVATION - BATHROOM 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A445b2DELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A445b3DELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A010 4D QQCON BATH EAST ELEV SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KKCON LOFT 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 SCALE: 1/2" = 1'-0" DRAWING REF: A445b5DFRAMING PLAN - FLOOR SLAB INFILL 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 KSCON 403 2.15 2.20 2.16 2.3 2.37 2.22 2.5 2.2 2.1 2.7 2.4 2.43 2.3 2.4 2.17 2.43 2.19 KSCON 403 TA-1 PF-1 TA-3 KSCON 403 ALIGNT-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 KSCON 403 8.10 26.6 26.6 8.1 8.5 8.6 8.7 27.1 A446 2D 4D 5D 6D A446 1E 1A A446 GR-A 2.5 2.9 2.2 2.3 2.3 2.15 2.16 2.17 OPEN QQCON+ 503 2.4 2.43 2.37 2.43 2.4 2.30 2.18 2.72 2.51 QQCON+ 503 OPEN 22.1 26.6 26.6 22.5 23.1 A446 2E A446 6E 3E 4E 5E 1A A446 26.6 OPEN QQCON+ 503 TA-1 PF-1 PF-2 PF-3 TA-2 TA-4 TA-3 TA-6 TA-7 TA-5 PF-5 PF-4 OPEN QQCON+ 503 ALIGNT-01 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 W WD-001 W CT-002 W SRD-001 KSCON 403 C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. OPEN 2.26 9.6 9.6 2.6 2.6 26.7 26.7C GYP 7' - 0" A.F.F. B CTB-001 W VWC-200 W SRD-001 B CTB-001 W VWC-200 B CTB-001 W SRD-001 T PNT-002 B CTB-001 W CT-002 W SRD-001 B CTB-001 W VWC-200 1A A446 15 RISERS @ 6.73"8'-4"1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAILUSE 7/11/2016 11:18:16 AMENLARGED GUESTROOM PLANS - KING CONDO SPIRAL THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET A446 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.6 REMOVE CEILING MOUNTED LIGHT FIXTURES. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.18 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.51 REMOVE RAILING. 2.72 REMOVE FLOOR SLAB. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1132BDEMO PLAN - K CONDO SPIRAL SCALE: 1/4" = 1'-0" DRAWING REF: A1135BFF&E PLAN - K CONDO SPIRAL SCALE: 1/4" = 1'-0" DRAWING REF: A1134BFINISH PLAN - K CONDO SPIRAL SCALE: 1/4" = 1'-0" DRAWING REF: A1133BCONSTRUCTION - K CONDO SPIRAL SCALE: 1/4" = 1'-0" DRAWING REF: A1133CDEMO PLAN - K CON SPIRAL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1134CCONSTRUCTION - K CON SPIRAL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1136CFF&E PLAN - K CON SPIRAL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1135CFINISH - K CON SPIRAL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A123 6B RCP -K CONDO SPIRAL SCALE: 1/4" = 1'-0" DRAWING REF: A4462DELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4463EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4464EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4465EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4462EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4466EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4461EBATHROOM - ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446 4D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446 5D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446 6D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4461ASECTION - STAIR KING CONDO 7/11/16 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 DWREF.DWREF. DWREF.DWREF. KCONR 403 2.15 2.16 2.3 2.37 2.22 2.1 2.1 2.7 2.4 2.43 2.3 2.4 2.17 2.43 2.19 KCONR 403 TA-24 TA-23 WTR-103 WTR-102 UPH-106.1 UPH-106 CSG-112 UPH-105 UPH-105.2 UPH-105.1 CSG-113 UPH-108 EQU-103 UPH-108 MIR-202 ART-200 ART-105 EQU-103.1 KCONR 403 2 1/2" 7 1/2" 2'-2 1/2"2'-6"5'-10"4'-2"4'-3"3'-3 1/2"2'-8 1/2" 12'-11 3/4" 3'-3 1/2" 4" 6'-0" 1'-1 3/4" 5'-6"5 1/2"1'-3 3/4" ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W PNT-003 F CT-001 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 9.2 KCONR 403 26.6 26.6 8.1 8.5 8.6 8.7 27.1 A446a 2B 4B 5B 6B A446a 2C A446b A446a 3C 4C 5C A4a GR-S 9.22 3'-0"3.3 HARDWARE #2 HARDWARE #1 4.1 8.16 8.8 8.10 23.3 23.1 13.1 2.20 1 3/4"1'-0"5'-5 1/2" 5C A445a SIM 6C2D 2D A501 2A SIM A453 2B 5B A453 2C 4CA500 4B 4C KCONR 403 C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. OPEN 2.26 9.6 9.6 2.6 2.6 26.7 26.7C GYP 7' - 0" A.F.F.+ - + - + - 9.25 T PNT-002 W PNT-003 B VB-001 T PNT-002 B CTB-001 W VWC-200 TA-23 TA-18 W PNT-003 B VB-001 5'-0"CL 8'-3"W PNT-003 B VB-001 6"CL33" W PNT-003 B VB-001 A501 6C SIM B CTB-001 T PNT-002 W PNT-003 B VB-001 W PNT-003W PNT-003 B VB-0011'-10"CL8" B CTB-001 W VWC-200 4'-0"CL 10" TA-24 W VWC-200 B CTB-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:37:23 PMENLARGED GUESTROOM PLANS - KCONR (ROOM 403) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A446a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.6 REMOVE CEILING MOUNTED LIGHT FIXTURES. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 3.3 PATCH FLOOR WHERE SPIRAL STAIR WAS REMOVED. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.22 PROVIDE STONE TOP ON 3/4" PLYWOOD. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -KCONR SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KCONR SCALE: 1/4" = 1'-0"4A FINISH PLAN - KCONR SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -KCONR SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KCONR SCALE: 1/4" = 1'-0" DRAWING REF: A1142BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446a2CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446a 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446a 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446a 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446a 3C ELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A446a 4C ELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A446a 5C ELEVATION - KITCHEN 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A003 6C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A0032DELEVATION - BATHROOM C EXIST 9 9 C PNT-001 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 2.5 2.9 2.3 2.3 2.15 2.16 2.17 OPEN KCONR+ 503 2.4 2.43 2.37 2.43 2.4 2.30 2.18 2.72 2.51 2.19 3'-4 1/2"KCONR+ 503 OPEN 26.6 26.6 22.5 23.1 A446b 2C A446b 3C 4C 5C 6C 26.6 A446b 2B 3B 4B 5B GR-A 3.1 2'-3 1/2" 6'-7 1/2"6.2 GR-Db 7'-3" EQ EQ A500 1D 13.113.1 5'-4" 1'-11" A445b 2B 5B A500 2A 2D A002b 4C 22.1 A501 2A SIM 3'-0" OPEN KCONR+ 503 TA-18 TA-7 TA-20 TA-23 TA-21 TA-22 TA-16 MIR-200 CSG-101 BED-101 BED-101.1 BED-100 CSG-100 LTG-100 LTG-101 CSG-100 UPH-102.2 UPH-102.1 UPH-102.3 ART-101 ART-102UPH-107 LTG-103 CSG-115 UPH-100 UPH-100.1 CSG-102 LTG-102ART-100 BED-102 EQU-103 MIR-100 TA-25 MIR-203 1'-0"10.3 EQU-103.1 OPEN KCONR+ 503 ALIGNT-01 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 W WD-001 W CT-002 W SRD-001 9.2 B CTB-001 W SRD-001 T PNT-002 5'-0"EQ 1'-6" EQ B CTB-001 W VWC-200W SRD-001 TA-23 B CTB-001 W CT-002 MIR-200 EQ EQCL 4'-2"7'-6"W PNT-003W SRD-001 B CTB-001 W VWC-200 1'-10"CL8"CL4'-0"CL1'-8" W PNT-003 B VB-001CL5'-0"CL2'-2" CL4'-0" W WD-001 B VB-001 CLCL 54" 48"CL36"56"W PNT-003 9 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. W PNT-003 B VB-001 CL 2'-6"CL5'-0"W PNT-003 B VB-001 46" AFFCL 60" EQU-103 4'-0"TA-18 C EXIST 7' - 0" A.F.F. C EXIST OPEN 9.25 C PNT-001 C PNT-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:37:36 PMENLARGED GUESTROOM PLANS - KCONR LOFT (ROOM 503) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A446b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.18 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.51 REMOVE RAILING. 2.72 REMOVE FLOOR SLAB. 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN - KCONR LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN - KCONR LOFT SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - KCONR LOFT SCALE: 1/4" = 1'-0"4A FINISH PLAN - KCONR LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A446b 6C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446b 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446b2CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446b3CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446b 5C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A446b2BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446b 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446b 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A446b 5B ELEVATION 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A0032DELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KCONR LOFT 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 REF Q1 438 A447 3C 2C 5C 4C A447 2B 4B6B 5B 8.1 8.5 8.6 8.7 27.1 22.5 23.2 23.3 8.10 26.6 26.6 22.4 22.7 GR-A HARDWARE #1 26.3 8.16 4.1 8.8 A500 2A A002b 4D 22.2 23.1 A451a 2B 5B 9 Q1 438 2.22 2.3 2.17 2.30 2.7 2.1 2.15 2.16 2.5 2.19 2.3 2.4 2.43 2.4 2.43 2.25 Q1 438 TA-18 TA-7TA-13 TA-21 TA-19 TA-16 CSG-104 LTG-100 CSG-100 WTR-103 WTR-102 UPH-100 UPH-100.1 LTG-102 ART-100 EQU-100 UPH-106.1 ART-101 ART-102 LTG-104 MIR-100 MIR-200 BED-103 BED-104 BED-104.1 BED-105 UPH-106 CL3'-6"CL6'-0 3/4"WTR-100 & WTR-101 LTG-101 CSG-100 MIR-203 10.3 A501 3D CSG-102 A500 3A Q1 438 ALIGN T-01 T-02 F CT-001 W VWC-200 B CTB-001 F CT-001 C PNT-001 B CTB-001 F CPT-100 C PNT-001 W PNT-008 B VB-001 W WD-001 W SRD-001 9.2 W CT-002 Q1 438 C EXIST 7' - 0" A.F.F. C EXIST 7' - 6" A.F.F. C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. 2.26 9.6 9.6 9.6 26.7 26.7 26.7 26.5 C GYP 7' - 0" A.F.F. C EXIST 6' - 9 1/2" A.F.F. MATCH ADJACENT + - + -+ - PNT-001 PNT-001 PNT-001 A500 6B SIM B CTB-001 W CT-002 CL60"CL EQEQ B CTB-001 W VWC-200 W SRD-001 4'-6"CLCL 1'-0" CLEQ EQ 1'-10"CLW SRD-001 B CTB-001 W VWC-200 W SRD-001T PNT-002 5'-0"EQ 1'-10" EQ 1'-0"4'-2"W PNT-008 B VB-001 WTR-103 WTR-100VAL WTR-102 ART-100 T PNT-002 W WD-001 B VB-001 WTR-100VAL WTR-103 WTR-102 60"MIR-100 CL1'-6"6" CL 8'-6" W PNT-008 NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. CL4'-10 1/2" W PNT-008 B VB-001 CL CL26"24" CL60" AFFART-101 ART-102 W PNT-008 B VB-001 CL54" AFFUPH-100 UPH-100.1 LTG-102 CL 42"WTR-100 & WTR-101 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:37:49 PMENLARGED GUESTROOM PLANS - Q1 (ROOM 438) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A447 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.2 REFINISH AND REGLAZE TUB TO LIKE NEW CONDITION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A113 3A CONSTRUCTION PLAN -Q1 SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -Q1 SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - Q1 SCALE: 1/4" = 1'-0"4A FINISH PLAN - Q1 SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - Q1 SCALE: 1/4" = 1'-0" DRAWING REF: A4473CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A447 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4475CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4472CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4472BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A447 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A447 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A447 6B ELEVATION 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 9 9 99 9 08/02/2017 01/11/18 DW DW UP DWDW UP DW UP DW DW K+ 501 1A A448 3'-0"3'-0"14 TREADS @ 11"12'-10"EXIST STEEL BEAM - VERIFY IN FIELD11"1'-0" OPEN 26.6 23.1 22.1 22.5 23.2 23.3 26.6 26.6 GR-BR 1A A448 KCCON 401 8.1 8.5 8.6 8.7 27.1 26.6 26.6 22.5 GR-BR A4a 9'-0 1/2"2.1 2.7 2.2 2.30 2.37 2.22 2.20 2.14 2.22 2.3 2.3 2.3 2.4 2.4 2.43 2.43 2.4 2.15 2.16 2.17 2.43 2.5 KCCON 401 1A A448 OPEN 2.9 2.5 2.2 2.3 2.4 2.15 2.16 2.17 2.43 2.3 2.3 2.42.15 2.16 2.17 2.43 2.4 2.43 K+ 501 2.37 7'-0"15 RISERS @ 6.73"8'-4"KCCON 401 TA-1 PF-1 PF-2 PF-3 TA-2 TA-3 TA-6 TA-8 TA-5PF-7 KCCON 401 ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 K+ 501 3'-0"14 TREADS @ 11"12'-10"1'-1"EXIST STEEL BEAM - VERIFY IN FIELD1'-0"OPEN TA-1 PF-1 PF-2 PF-3 TA-2 TA-3 TA-6 TA-4 TA-7 PF-5 PF-4 TA-5 K+ 501 EXIST STEEL BEAM - VERIFY IN FIELD OPEN W SRD-001ALIGN T-01 C PNT-001 W VWC-200 F CT-001 B CTB-001 F CPT-100 C PNT-001 W PNT-003 B VB-001 F CPT-100 C PNT-001 W PNT-003 B VB-001 KCCON 401 C GYP 7' - 0" A.F.F. C GYP 6' - 10" A.F.F. C EXIST 7' - 0" A.F.F. OPEN C EXIST 7' - 0" A.F.F. 2.77 2.77 2.26 26.5 9.6 9.6 26.7 26.7 + - + -+ - 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:18:30 AMENLARGED GUESTROOM PLANS - KING CORNER CONDO (ROOM 401) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET A448 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.77 CEILING FIXTURE TO REMAIN AND RELAMPED WITH EDISON BASE LED LIGHT BULB. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1134BCONSTRUCTION PLAN -ROOM 401 - UPPER LEVEL/LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: D113 2A DEMO PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: D1132BDEMO PLAN - ROOM 401 - UPPER LEVEL/LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A4481ASECTION - STAIR KING CORNER CONDO SCALE: 1/4" = 1'-0"5A FF&E PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: A113 4AFINISH PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: A1135EFF&E PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: A113 6B FINISH PLAN - ROOM 401 SCALE: 1/4" = 1'-0" DRAWING REF: A1236ARCP - CORNER CONDO (ROOM 401) 7/11/16 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 DW UP DWDW UP DW UP 4A A501 KCCON 401 8.1 8.5 8.6 8.7 27.1 26.6 26.622.5 GR-BR A4a 9'-0"A448a 5C 6C A448a 2C 3C 4C 6B A448a 3B 2B 4B 5B GR-S A4a 9.2214 TREADS @ 11"12'-10" 3'-0"HARDWARE #1 8.8 8.8 23.3 8.10 8.10 13.1 23.2 23.1 22.2 22.7 8.16 4.1 A501 1C 1'-0"5C A445a SIM 1" 1" A002b 4D 22.4 A501 2A SIM 2.1 2.7 2.30 2.37 2.22 2.20 2.14 2.22 2.3 2.3 2.3 2.4 2.42.43 2.43 2.4 2.15 2.16 2.17 2.43 2.5 KCCON 401 2.13 KCCON 401 TA-7 TA-13 TA-21 TA-19 TA-16 TA-25 MIR-202 UPH-108UPH-108 CSG-112 CPT-102 CSG-114 EQU-103 UPH-109 WTR-100 & WTR-101 CLEQ EQ UPH-105.2 UPH-105.1 WTR-102 WTR-103 KCCON 401 ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W PNT-003 F CT-001 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 W SRD-001 9.2 KCCON 401 C GYP 7' - 0" A.F.F. C GYP 6' - 10" A.F.F.C EXIST 7' - 0" A.F.F. OPEN C EXIST 7' - 0" A.F.F. 2.26 26.5 9.6 9.6 26.7 26.7 + - + - PNT-001 PNT-001 C EXIST 9.25 9 W PNT-003 B VB-001 W PNT-003 B VB-001 30" TO CL 54" AFFT PNT-002 W PNT-003 B VB-001 A501 6C T PNT-002 W PNT-003 AT CLOSET INTERIOR ACCESS DOOR W PNT-003 B VB-001 W PNT-003 B VB-001 WTR-100 & WTR-101 WTR-100VAL T PNT-002 W PNT-003 B VB-001 B CTB-001 W VWC-200 T PNT-002 5'-0"CLEQ EQ B CTB-001 W VWC-200 W SRD-001 TA-25 4'-0"CL1'-6" 4A A501 W SRD-001 MIR-202CL 64" AFFCL19" TA-23 W SRD-001 B CTB-001 CLEQEQ CL1'-10"A501 1D 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:06 PMENLARGED GUESTROOM PLANS - KCCON (ROOM 401) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A448a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 0 DIVISION 00 - PROCUREMENT AND CONTRACTING 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.13 REMOVE TUB/SHOWER SURROUND. TUB/SHOWER TO REMAIN. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.20 FIREPLACE CONTROLS TO HAVE ONE HOUR TIMERS WITH AUTOMATIC SHUT OFF. METAL FLUES TO EXTEND ABOVE ROOF LINE AND VENTS. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.22 PROVIDE STONE TOP ON 3/4" PLYWOOD. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.2 REFINISH AND REGLAZE TUB TO LIKE NEW CONDITION. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.5 PROVIDE SINK AND FAUCET. 22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -KCCON SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -KCCON SCALE: 1/4" = 1'-0"5A FURNITURE PLAN - KCCON SCALE: 1/4" = 1'-0"4AFINISH PLAN - KCCON SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KCCON SCALE: 1/4" = 1'-0" DRAWING REF: A448a5CELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A448a2BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448a 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448a 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448a 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448a 6C ELEVATION - KITCHEN SCALE: 1/4" = 1'-0" DRAWING REF: A448a3CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448a 4C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448a6BELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448a2CELEVATION - BATHROOM 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 DW DN DW DN DW DN KCCON+ 501 4A A501 3'-0"14 TREADS @ 11"12'-10"3'-0" EXIST STEEL BEAM1'-2 1/4" 1'-0" OPEN 26.6 23.122.5 23.2 26.6 26.6 GR-BRA448c 2A A448b 5D A448c 1A 4E 5E 6E 2B 1B A448b 6A 6C 6B6D 6.3 6.2 3.1 3.4 GR-Db 2'-0" A500 1D 13.1 26.3 26.3 A500 2A A501 2A A002b 4C 22.1 A114 2E6'-0"KCCON+ 5011'-0"OPEN TA-25 TA-23 TA-21 TA-20 TA-22 TA-16 CSG-100 LTG-101 ART-102 LTG-100 CSG-101 BED-101 CSG-100 BED-102 BED-101.1 BED-100 ART-101 MIR-200 MIR-100 EQU-101.1 CL CL4'-6 3/4"1'-3" CL EQ EQ CLEQ EQ TA-18 MIR-203 1'-0"10.3 EQU-103 CSG-111 CSG-121 BED-103BED-103 BED-104BED-104 BED-104.1 BED-104.1 BED-105 BED-105 LTG-100 CSG-100 CSG-104CSG-104 KCCON+ 5013'-0"9 1/2"3'-0"14 TREADS @ 11"12'-10"1'-1"1'-2 1/4"1'-0" OPEN W SRD-001ALIGN T-01 W VWC-200 F CT-001 B CTB-001 F CPT-100 W PNT-003 B VB-001 F CPT-100 W PNT-003 B VB-001 W CT-002 F CT-001 B VB-001 W WD-001 W WD-001 OPEN 2.9 2.5 2.3 2.4 2.15 2.16 2.17 2.43 2.3 2.3 2.42.15 2.16 2.17 2.43 2.4 2.43 KCCON+ 501 2.37 2.86 2.19 C PNT-001 W PNT-003 W WD--001 B VB-001 CL4'-6" 1'-3"5'-0"W PNT-003 B VB-001 W PNT-003 B VB-001 W PNT-003 B VB-001CL60" AFFCLCL 26" 148" 6" W PNT-003 B VB-001 T PNT-002 W WD-001 B VB-001 CL CL7'-5"7'-1" 9W PNT-003 B VB-001 T PNT-002 W PNT-003 AT CLOSET INTERIOR C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F. PNT-001 PNT-001 PNT-001 C EXIST OPEN 9.25 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:19 PMENLARGED GUESTROOM PLANS - KCCON LOFT (ROOM 501) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A448b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: A1135BCONSTRUCTION PLAN -KCCON LOFT SCALE: 1/4" = 1'-0"5C FURNITURE PLAN - KCCON LOFT SCALE: 1/4" = 1'-0"3C FINISH PLAN - KCCON LOFT SCALE: 1/4" = 1'-0" DRAWING REF: D1133BDEMOLITION PLAN -KCCON LOFT KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.86 REMOVE CLOSET DOORS AND SHELVES. PREPARE FOR NEW. 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 3.4 EXTEND FLOOR FRAMING OVER TO TOP OF NEW WALL BELOW. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 6.3 42" HIGH GUARDRAIL. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 26.3 PROVIDE FACEPLATE AT PHONE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6AELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b6BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b6CELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 5D ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b4EELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 5E ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A448b 6E ELEVATION 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A1234DREFLECTED CEILING PLAN - KCCON LOFT 9 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 W SRD-001 B CTB-001 W VWC-200 W SRD-001 4'-0"CL1'-6"3 B CTB-001 W CT-002 MIR-200 CL60"EQ EQ 4'-6"3 4'-2" MIR-203 3 B CTB-001 W VWC-200 1'-10"5"CL CL3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:16:28 PMENLARGED GUESTROOM PLANS - KCCON LOFT (ROOM 501) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A448c 2211 N FRONTAGE RD, VAIL, COLORADO 81657 3 10/07/2016 ASI #1 SCALE: 1/4" = 1'-0" DRAWING REF: A448b1AELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448b1BELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448b2AELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A448b2BELEVATION - BATHROOM 3 10/17/2016 01/11/18 K2 202 A449 2B 3B 4B 5B A449 2C 3C 4C 5C 23.2 8.8 8.10 26.3 22.5 23.1 8.1 8.6 27.1 22.1 26.6 8.7 8.5 26.6 23.3 HARDWARE #2 HARDWARE #1 4.1 8.16A500 2A 3 A002b 4C 3 K2 202 2.3 2.43 2.25 2.4 2.14 2.22 2.3 2.15 2.16 2.17 2.19 2.5 2.1 2.7 2.43 2.4 2.73 2.70 2.70 2.70 2.30 2.9 K2 202 F CPT-100 C PNT-001 C PNT-001 W PNT-003 B VB-001 W VWC-100 F CT-001 W VWC-200 B CTB-001 F CT-001 B CTB-001 ALIGN T-01 T-02 9.2 11'-8 1/2" W SRD-001 1'-6" 3 K2 202 LTG-101 LTG-100 TA-7 TA-23 TA-21 WTR-102 & WTR-103 TA-25 TA-22 TA-20 CL CL10'-4 1/4"4'-5 3/4" UPH-100 UPH-100.1 ART-100 LTG-102 EQU-101.1 MIR-100 ART-102 CSG-100 CSG-101CL4'-6 1/2" 4'-2 1/2"CSG-100 ART-101 BED-100 BED-101.1 BED-101 BED-102 MIR-200 CSG-116L 3 TA-7 3 MIR-203 3 10.3 3 10.1 TA-16 3 3 A500 3A B VB-001 W PNT-003 WTR-102 & WTR-103 3 B CTB-001 W VWC-100 W PNT-003 W PNT-003 B VB-001 5'-0"5'-0"3W PNT-003 T PNT-002 CL CL2'-2"1'-9" CL5'-0"ART-101 ART-102 B VB-001B VB-001 W PNT-003 W PNT-003 W WD-002 B CTB-001 ART-100 WTR-102 & WTR-103 MIR-100 CL4'-6"CLCL 10'-4 1/4" 4'-4" B CTB-001 W SRD-001 5'-0"EQ 3 B CTB-001 W VWC-200MIR-200 3'-4"CL2'-3"4'-2"8" 3 B CTB-001 W VWC-200 1'-10"CLCL 8"3 4'-0"CL1'-4" B CTB-001 W VWC-200 T PNT-002 K2 202 C EXIST 7' - 0" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 7' - 4" A.F.F. C EXIST 7' - 0" A.F.F. MATCH ADJACENT C GYP 7' - 0" A.F.F. 9.6 9.6 9.6 26.7 26.7 26.7 26.5 + - + - + - PNT-001 PNT-001 PNT-001 A500 6B SIM 3 3 3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:16:41 PMENLARGED GUESTROOM PLANS - K2 (ROOM 202) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A449 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.9 REMOVE TUB AND SURROUND. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.25 REMOVE PTAC UNIT AND TURNOVER TO OWNER. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.70 REMOVE GRAB BARS. 2.73 REMOVE SHELF. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A112 3A CONSTRUCTION PLAN -K2 SCALE: 1/4" = 1'-0" DRAWING REF: D1122ADEMOLITION PLAN -K2 SCALE: 1/4" = 1'-0"4AFINISH PLAN - K2 SCALE: 1/4" = 1'-0"5AFURNITURE PLAN - K2 SCALE: 1/4" = 1'-0" DRAWING REF: A4492BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A449 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A449 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A449 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4492CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4493CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4494CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4495CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - K2 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 3 10/17/2016 01/11/18 K3 206 2.22 2.3 2.4 2.2 2.43 2.34 2.14 2.16 2.17 (FORMER GUEST LAUNDRY) K3 206 22.6 8.1 27.1 8.7 12.4 8.8 8.10 23.1 GR-A GR-E 23.3 23.2 10.1 26.6 26.6 26.3 A450 2B 3B 4B 6B A450 2C 3C 4C 5C ALIGN A4a A4a 10'-0 3/4"5'-0" 22.5 8.5 8.6 4.1 8.16 A500 2A 3 A002b 4C 3 K3 206 ALIGN T-01 T-02 F CPT-100 C PNT-001 W PNT-003 B VB-001 W VWC-100 F CT-001 B CTB-001 C PNT-001 F CT-001 W VWC-200 B CTB-001 W CT-002 9.2 W SRD-001 3 K3 206 TA-7 TA-20 TA-23 TA-21 TA-22 TA-18 TA-16 LTG-100 LTG-101 WTR-102 & WTR-103 UPH-100 UPH-100.1 LTG-103 CSG-107 MIR-100 EQU-101.1 ART-100 LTG-102 CSG-101 CSG-100 CSG-100 BED-100 BED-101.1 BED-101 BED-102 UPH-102 UPH-102.2 UPH-102.3 UPH-102.1 ART-101 ART-102 MIR-200 CLCL5'-4" 8'-11"CL CL3'-8"4'-6" A500 3A A500 5A 3 TA-25 3 3 3 CSG-116R 10.1 3 W PNT-003 B CTB-001 W PNT-003 T PNT-002 B VB-001 W VWC-100 CLCL 44" 54" CSG-101 LTG-101ART-102 CL36" AFF5'-0"3 W PNT-003 B VB-001 WTR-102 & WTR-103 3 B VB-001 W PNT-003 MIR-100 ART-100 CL CL64"107"CL54"B VB-001 W PNT-003 T PNT-002 CLCL EQ EQ ART-101 ART-102 CL60" AFFW SRD-001 B CTB-001 W VWC-200 W SRD-001 4'-2"8" 3 B CTB-001 5'-0"CL60" AFFW VWC-200 B CTB-001 W VWC-200 W SRD-001 T PNT-002 5'-0"EQ 1'-6" EQ 1'-10"5"CL CL3 4'-0"CL1'-6" 3 C EXIST 7' - 0" A.F.F. 2.6 2.6 26.10 26.10 26.5 26.10 C GYP 8' - 0" A.F.F. C GYP 8' - 0" A.F.F. K3 206 PNT-001 PNT-001 PNT-001 SIM A500 6B 3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:16:50 PMENLARGED GUESTROOM PLANS - K3 (ROOM 206) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A450 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.6 REMOVE CEILING MOUNTED LIGHT FIXTURES. 2.14 REPAIR AND REFINISH WINDOW SILLS TO 'LIKE NEW' CONDITION. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.22 REMOVE WINDOW TREATMENTS. 2.34 REMOVE EQUIPMENT AND RETURN TO OWNER. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 10.1 PROVIDE COFFEE STATION AND FRIDGE. POWER OUTLET REQUIRED. 10.3 LOCATE MAGNIFIED MIRROR WITHIN REASONABLE CORD REACH RANGE OF ELECTRICAL OUTLET. IN ROOMS WHERE APPLICABLE, INSTALL TOWEL BAR ON OPPOSITE WALL OF APPROPRIATE MAGNIFIED MIRROR LOCATION. 12.4 SIZE OF VERTICAL PIECE OF CASEWORK IS THE SAME. MAKE BENCH HORIZONTAL PIECE TO SIZE. 22.5 PROVIDE SINK AND FAUCET. 22.6 PROVIDE WC. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.2 PROVIDE AMANA PTAC AIR UNIT. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.10 PROVIDE CEILING MOUNTED LIGHT FIXTURE 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1122ADEMOLITION PLAN -K3 SCALE: 1/4" = 1'-0" DRAWING REF: A1123ACONSTRUCTION PLAN -K3 SCALE: 1/4"= 1'-0" DRAWING REF: A112 4A FINISH PLAN - K3 SCALE: 1/4" = 1'-0" DRAWING REF: A112 5A FURNITURE PLAN - K3 SCALE: 1/4" = 1'-0" DRAWING REF: A450 3B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 2 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A450 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: 22BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A4502CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4503CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4504CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A4505CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A1226AREFLECTED CEILING PLAN - K3 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 3 10/17/2016 01/11/18 DKL 436 A451a 2B 6B 5B 4B HARDWARE #1 8.8 8.9 26.6 27.1 8.7 A501 2A SIM GR-S 3'-0" MIN CLR 7'-2 1/4"4'-2 1/2" 6'-4 1/2" DKL 436 CSG-112 UPH-105 UPH-105.2 UPH-105.1 CSG-113 UPH-108 EQU-103 CL WTR-103 WTR-102 EQU-103.1 UPH-106 UPH-106.1 DKL 436 2.1 2.7 2.3 2.4 2.15 2.16 2.17 2.43 DKL 436 F CPT-100 C PNT-001 W PNT-003 B VB-001 F CT-001 B VB-001 ALIGN T-01 T-02 9.2 C PNT-001 W PNT-003 DKL 436 C EXIST 7' - 0" A.F.F. PNT-001 PNT-001 9.6 26.7 9.6 26.7 A500 6B SIM C EXIST VARIES 9.25 9 6"CL B VB-001 W PNT-003 W PNT-003 B VB-001B VB-001 W PNT-003 CLEQ EQ 6"A501 6C SIM W PNT-003 B VB-001 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:29 PMENLARGED GUESTROOM PLANS - DKL (ROOM 436) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A451a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 KEYNOTES 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.9 PROVIDE PTAC LENGTH WINDOW TREATMENTS. 9.2 PATCH, REPAIR, AND PREP WALLS AS REQUIRED TO RECEIVE NEW PAINT FINISH. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -DKL SCALE: 1/4" = 1'-0" DRAWING REF: A452 5AFURNITURE PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A4522ADEMOLITION PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A452 4A FINISH PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A4526AREFLECTED CEILING PLAN - DKL SCALE: 1/4" = 1'-0" DRAWING REF: A0102BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 6B ELEVATION 9 9 9 9 9 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 DKL+ 536 A451b 4E 3E 5E 6E A451c 3A 2A A451c 2B A451b 5C 6C 5D 6D 13.1 3.1 13.1 6.2 26.6 26.6 23.1 22.1 26.6 22.5 6.2 26.6 2'-0" MIN CLRMIN CLR2'-0"A4a GR-DcGR-Dc A4a A500 1D A500 2A A500 1D OPEN ALIGN 1A 1B 3B A501 2A SIM ALIGN WALL WITH EXISTING CEILING BEAM ABOVE ALIGN WALL WITH EXISTING CEILING BEAM ABOVE 3'-0" DKL+ 536 2.5 2.51 2.19 2.9 2.3 2.4 2.43 2.37 2.3 2.4 2.15 2.16 2.17 2.18 2.432.3 2.4 2.15 2.16 2.17 2.18 2.43 DKL+ 536 TA-18 TA-7 TA-20TA-23 TA-21 TA-22 TA-16 TA-25 MIR-100 MIR-200 MIR-203 LTG-101 BED-100 BED-101 BED-101.1 BED-102 CSG-100 CSG-101 EQU-101.1 LTG-101 BED-100 BED-101 BED-101.1 BED-102 CSG-100 CSG-101 EQU-101.1ART-102 ART-101 CSG-121 CSG-121 ART-102 ART-101 LTG-100 CSG-100 CSG-100 LTG-100 DKL+ 536 ALIGN T-01 F CPT-100 C PNT-001 W PNT-003 B VB-001 C PNT-001 W VWC-200 F CT-001 B CTB-001 W WD-001 W CT-002 W SRD-0010"C PNT-001 W VWC-200 F CT-001 B VB-001F CPT-100 C PNT-001 W PNT-003 B VB-001 W WD-001 W WD-001 B VB-001 CLCL 50 1/2" 27"60"36"9NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. W PNT-003 B VB-001 CL CL 3'-10 3/4"2'-2" W PNT-003 B VB-001 W PNT-003 B VB-001 T PNT-002 W PNT-003 AT CLOSET INTERIOR W PNT-003 B VB-001 T PNT-002 W PNT-003 AT CLOSET INTERIOR W PNT-003 B VB-001 EQU-101.1 2'-6"CL 3'-3" W PNT-003 B VB-001 CL CL 5'-0 3/4"2'-2" 4'-10 1/4" CL5'-0"W WD-001 B VB-001 CLCL26 1/2" 51 1/2" NOTE: WALL SCONCE SHOULD BE MOUNTED SO THAT ROCKER SWITCH IS LOCATED 40" AFF. C EXIST 7' - 0" A.F.F. PNT-001 PNT-001 PNT-001 C EXIST OPEN 9.25 C EXIST OPEN 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:41 PMENLARGED GUESTROOM PLANS - DKL LOFT (ROOM 536) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A451b 2211 N FRONTAGE RD, VAIL, COLORADO 81657 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 KEYNOTES 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.5 REMOVE SINK, FAUCET AND VANITY. 2.9 REMOVE TUB AND SURROUND. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.18 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.37 REMOVE STAIR, TREADS, AND RAILING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.51 REMOVE RAILING. 3.1 INFILL AND LEVEL FLOOR. SEE STRUCTURAL DRAWINGS. 6.2 REINFORCE FLOORS IN ORDER TO REDUCE NOISE TO GUESTROOMS BELOW. 9.25 CEILING PAINT TO BE SPRAY APPLIED. PAINT CEILING BOARD ONLY, BEAM AND TRIM PAINT EXISTING TO REMAIN. 13.1 PROVIDE STAIR, GUARDRAIL AND HANDRAIL 22.1 PROVIDE SHOWER STALL WITH DUAL BYPASS DOOR AND SHOWERHEAD. 22.5 PROVIDE SINK AND FAUCET. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. SCALE: 1/4" = 1'-0" DRAWING REF: A1134ACONSTRUCTION PLAN - DKL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A5012ADEMOLITION PLAN - DKL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A5012CFURNITURE PLAN - DKL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A501 6A FINISH PLAN - DKL LOFT SCALE: 1/4" = 1'-0" DRAWING REF: A451b 4E ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b 5E ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b 6E ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b3EELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b 5C ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b 6C ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b5DELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A451b 6D ELEVATION 99 9 SCALE: 1/4" = 1'-0" DRAWING REF: A1234CREFLECTED CEILING PLAN - DKL LOFT 9 9 9 9 NOTE: ALL EXISTING LOFT WALL SCONCES TO BE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 1'-10"4'-0"CL CL CL1'-8" 8" W SRD-001W VWC-200 B CTB-001 TA-23 W SRD-001 B CTB-001 W CT-002 4'-0"EQ EQ MIR-200 CL 7'-6"TA-18 4'-0"W VWC-200 B CTB-001 W VWC-200 B CTB-001 W SRD-001 5'-0"EQ 1'-6" EQ T PNT-002 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:48 PMENLARGED GUESTROOM PLANS - DKL LOFT (ROOM 536) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A451c 2211 N FRONTAGE RD, VAIL, COLORADO 81657 9 7/21/2017 CCD-005 KEYNOTES SCALE: 1/4" = 1'-0" DRAWING REF: A451b1AELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A451b 2A ELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A451b 3A ELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A451b2BELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A451b 3B ELEVATION - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: A451b1BELEVATION - BALLROOM 9 NOTE: ALL EXISTING LOFT WALL SCONCES TOBE REMOVED AND REPLACED PER RFI#111 9 08/02/2017 01/11/18 A452 5B 6B 2B 4B A452 5C 2C 3C 4C K4L 411 8.6 8.1 8.5 8.7 4.1 8.16 27.123.1 22.7 8.10 8.8 23.3 26.6 26.3 K4L 411 2.3 2.4 2.15 2.16 2.17 2.1 2.7 2.19 2.43 2.3 2.4 2.43 2.22 K4L 411 REFER TO SHEET A441 FOR FINISH INFORMATION. K4L 411 REFER TO SHEET A441 FOR FF&E INFORMATION. K4L 411 C EXIST 8' - 0" A.F.F. 9.6 26.7 C EXIST 7' - 0" A.F.F. C EXIST 7' - 0" A.F.F.26.5 26.7 9.6 9.6 26.7 2.26 C PNT-001 C PNT-001 C PNT-001 REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. REFER TO SHEET A441 FOR FF&E AND FINISH TAGS.5'-0"4'-2"EQ 1'-6" EQ REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. REFER TO SHEET A441 FOR FF&E AND FINISH TAGS. MIR-202 4'-6"CL1'-10" EQ EQ 4'-9"CLREFER TO SHEET A441 FOR FF&E AND FINISH TAGS. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:38:59 PMENLARGED GUESTROOM PLANS - K4L (ROOM 411) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A452 2211 N FRONTAGE RD, VAIL, COLORADO 81657 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN -K4L SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN -K4L SCALE: 1/4" = 1'-0" DRAWING REF: A113 4A FINISH PLAN - K4L SCALE: 1/4" = 1'-0" DRAWING REF: A113 5AFURNITURE PLAN -K4L SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - K4L SCALE: 1/4" = 1'-0" DRAWING REF: A4522BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A452 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A452 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A452 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A0102CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A0103CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A0104CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A010 5C ELEVATION - BATHROOM 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. KEYNOTES 9 08/02/2017 01/11/18 A453 6B 2B 4B 5B A453 5C 2C 4C 3C 22.4 22.7 KEXL 402 4.1 8.1 8.5 8.6 8.7 8.16 27.1 23.3 26.6 26.6 23.1 26.3 8.8 8.10 8.8 8.10 4A A500 5D 2.3 2.4 2.15 2.16 2.17 2.1 2.7 2.19 2.22 KEXL 402 KEXL 402 REFER TO SHEET A444 FOR FINISH INFORMATION. KEXL 402 REFER TO SHEET A444 FOR FURNITURE INFORMATION. KEXL 402 C EXIST 8' - 0" A.F.F. 9.6 26.7 C EXIST 7' - 0" A.F.F. 9.6 26.5 26.7 C EXIST 7' - 0" A.F.F. 9.6 26.7 2.26 C PNT-001 C PNT-001 C PNT-001 REFER TO SHEET A444 FOR FF&E AND FINISH TAGS.REFER TO SHEET A444 FOR FF&E AND FINISH TAGS. REFER TO SHEET A444 FOR FF&E AND FINISH TAGS.REFER TO SHEET A444 FOR FF&E AND FINISH TAGS. REFER TO SHEET A444 FOR FF&E AND FINISH TAGS.4'-2"EQ 1'-6" EQ 5'-0"REFER TO SHEET A444 FOR FF&E AND FINISH TAGS. REFER TO SHEET A444 FOR FF&E AND FINISH TAGS. MIR-202 EQ EQ 1'-10" 4'-6"CLCL4'-9"REFER TO SHEET A444 FOR FF&E AND FINISH TAGS. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:39:10 PMENLARGED GUESTROOM PLANS - KEXL (ROOM 402) THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A453 2211 N FRONTAGE RD, VAIL, COLORADO 81657 9 7/21/2017 CCD-005 SCALE: 1/4" = 1'-0" DRAWING REF: A1133ACONSTRUCTION PLAN - KEXL SCALE: 1/4" = 1'-0" DRAWING REF: D1132ADEMOLITION PLAN - KEXL SCALE: 1/4" = 1'-0" DRAWING REF: A113 4A FINISH PLAN - KEXL SCALE: 1/4" = 1'-0" DRAWING REF: A1135AFURNITURE PLAN - KEXL SCALE: 1/4" = 1'-0" DRAWING REF: A1236AREFLECTED CEILING PLAN - KEXL SCALE: 1/4" = 1'-0" DRAWING REF: A0032BELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 4B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A003 5B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A010 6B ELEVATION SCALE: 1/4" = 1'-0" DRAWING REF: A0032CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A010 3C ELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A0034CELEVATION - BATHROOM SCALE: 1/4" = 1'-0" DRAWING REF: A010 5C ELEVATION - BATHROOM 2.1 REPAIR AND REFINISH DOOR TO 'LIKE NEW' CONDITION. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.4 REMOVE WALL BASE. 2.7 REMOVE EMERGENCY EVACUATION PLANS SIGNAGE. 2.15 REMOVE WALL MOUNTED MIRRORS. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.19 REMOVE WALL MOUNTED HAIR DRYER. TURNOVER TO OWNER. 2.22 REMOVE WINDOW TREATMENTS. 2.26 REMOVE RECESSED LIGHTING AND EGG CRATE STYLE LENS LIGHTING. 4.1 PROVIDE STONE THRESHOLD AT DOOR. 8.1 PROVIDE SOUND STRIPPING AND AUTOMATIC DROP DOWN SEALS FOR ACOUSTIC PROTECTION. 8.5 PROVIDE SECURITY LATCH. 8.6 PROVIDE LOW ENERGY AUTOMATIC OPERATING LOW PROFILE OVERHEAD DOOR CLOSER. 8.7 PROVIDE COVER FOR DOOR VIEWER. 8.8 PROVIDE WINDOW VALANCE. 8.10 PROVIDE FLOOR LENGTH WINDOW TREATMENTS. 8.16 PREP AND REPAIR ALL DOORS FOR NEW OWNER SUPPLIED RFID SYSTEMS. 9.6 POPCORN CEILINGS TO REMAIN. COVER WITH 1/4" GYPSUM BOARD, TAPE AND SPACKLE TO SMOOTH FINISH AND PAINT. 22.4 PROVIDE ALL NEW TUB CHROME: TRIM, SPOUT, CONTROL HANDLE, STOPPER AND OVERFLOW DRAIN. 22.7 PROVIDE NON-SLIP BATHTUB BOTTOM APPLICATION. 23.1 GC TO CHECK EXISTING BATH EXHAUST COMPLIANCE. 23.3 PROVIDE REMOTE, WALL MOUNTED DIGITAL THERMOSTAT WITH 5" BACKLIT SCREEN AT 60" A.F.F. 26.3 PROVIDE FACEPLATE AT PHONE. 26.5 PROVIDE MOISTURE RESISTANT CEILING FIXTURE. 26.6 PROVIDE ILLUMINATED ROCKER-TYPE LIGHT SWITCH AT ENTRY DOOR. 26.7 PROVIDE LED LIGHT TO REPLACE EXISTING. 27.1 PROVIDE DOUBLETREE BRAND EMERGENCY EVACUATION PLAN SIGNAGE. KEYNOTES 9 08/02/2017 01/11/18 REFA500 2B 2C VIF CL7"9" 4" CL1'-8" CL CLEQ EQ 2D 2E STN-002 COUNTERTOP & BACKSPLASH WITH SEMI-RECESSED SINK 4D A500 4E A500 2D 2E CL CL EQEQ BACKLIT MIRROR EQ1 1/2"EQ4"4" 2'-10" 4"3'-6"5" EQ 1'-6" EQ 5 3/4" 4'-10 3/4" EQ EQ STN-002 COUNTERTOP & BACKSPLASH WITH SEMI-RECESSED SINK OPEN SHELF, TYP., WOOD VENEERRECESSED TOE KICK WOOD PANEL WITH REVEAL, PLAM-001 FILLER SCRIBE TRIM PANEL (EACH SIDE) 4D A500 4E A500 4" EQ 1 1/2"EQ 4" 4"2'-10"3'-4"CL 1'-3 3/4"1" 1/2" CL 1'-4 3/4"ALIGNBACKLIT MIRROR BACKLIT MIRROR STN-002 COUNTERTOP & BACKSPLASH W/ SEMI- RECESSED SINK WOOD PANEL, PLAM-001 WOOD REVEAL, PLAM-001 A500 3C A500 3CSim OPP 3D A500 2'-3 1/2"VERIFY IN FIELD 1" ALIGN A500 3BSim 2' - 1" .ALIGN WITH WALL 2'-3 1/2" OPEN TO BEYOND VERIFY IN FIELDVERIFY IN FIELD 4'-6 1/4"3D A500 1" 1" 2'-1"4" TO CEILINGEXTENDVERIFY IN FIELDUNDERCOUNTER REFRIGERATOR SHELF 2'-8" RECEPTACLE PULL OUT DRAWER FOR COFFEE CUBBY FOR SAFE DROPPED DOWN HATCH DOOR WITH HINGES ON BOTH SIDES9 1/2" 3'-11"1'-6"1'-0"9 6" 6" DOOR PULL 1 1/2" CL 18"1 1/2"CL1 1/2" CL24"PLAM-001 MITERED CORNER, TYP. ALL SURFACES, INTERIOR & EXTERIOR, TO BE FINISHED, TYP. A500 6A 5C A500 1 1/2" 1 1/2"18"1 1/2" 1 1/2" 24" 5C A500 PLAM-001MITERED CORNER, TYP. ALL SURFACES, INTERIOR & EXTERIOR, TO BE FINISHED, TYP.1 1/2"1 1/2" 1'-6"1 1/2" 1'-6" PLAM-001, ALL SURFACES MITERED CORNER, TYP. ALL SURFACES, INTERIOR & EXTERIOR, TO BE FINISHED, TYP. MITERED CORNER, TYP. 3/4" PLYWOOD (EXT. GRADE) STN-002 COUNTERTOP & BACKSPLASH W/ SEMI- RECESSED SINK 4" 4" EQ 1 1/2"EQ 4" CL1" CL 1" CLCL3/4"2'-10"STN-002 BASE WOOD PANELS, PLAM-001 CL 1" CL 1'-8" MOUNT OUTLET TO FACE OF MILLWORK. OUTLET COVER TO MATCH MILLWORK FINISH PLAM-001 PLAM-001 COORDINATE OPENING WITH UNDERCOUNTER REFRIGERATOR REQUIREMENTS CONFIRM WITH FRIDGE DEPTH REQ. 2'-3 1/2" VERIFY IN FIELD CL 1" SHELF MOUNT OUTLET TO FACE OF MILLWORK. OUTLET COVER TO MATCH MILLWORK FINISH PLAM-001 TRACK FOR PULL-OUT DRAWER PULL-OUT DRAWER FOR COFFEE SERVICE 4" 2'-8"EQALIGN TOP OF PORTAL UNIT WITH CEILING AND SECURE VERIFY IN FIELDSAFE1'-0" 9 1/2" 9 DOOR PULL1'-0"DOOR PULL MITERED CORNER, TYP.3/4" PLYWOOD (EXT. GRADE) STN-002 COUNTERTOP & BACKSPLASH W/ SEMI- RECESSED SINK STN-002 BASE OPEN SHELVES ALL EXPOSED SURFACES TO BE FINISHED, TYP.4"4" CLEQ CL 1 1/2"CL EQ 4" CL 1" CL3/4" CL 1"2'-10"CL 1'-8" PLUMBING CHASE REMOVABLE PANEL 4" CLR REMOVABLE PANEL VIF VARIES 8"2" NEW PAINT GRADE CORNICE BOARD; SECURE TO WALL, BOTH ENDS. PAINT PT-007 DENOTES RETURN NOTE: WHERE WINDOW IS WITHIN 3" OF A CORNER OR BUMP OUT, NO RETURN IS TO BE USED. CLEAT DIRECTLY TO BUMP OUT. L BRACKET V.I.F. PTAC BELOW 1E A500 A500 6CSim 1'-0" 6" MIN VARIES 1'-2"VARIES1B A500 GR-Da STAINED WOOD SHELF ON WOOD BLOCKING POLISHED CHROME COAT ROD 4'-4"1'-2"4'-0" MAX1'-0"2'-0" MINVARIES 1'-6"1A A500 GR-Db 6'-0"4'-4" AFF FOR ADA CLOSETS5'-10"4'-0" MAX AFF FOR ADA CLOSETS5'-6"STAINED WOOD SHELF ON WOOD BLOCKING POLISHED CHROME COAT ROD1'-6" 1'-0" 3" 3" 3" 9" CEILING MOUNT DRAPERY 2-1/4" X 2-1/4" 18 GA LS50 ANGLE FRAMING; 12" O.C. SIMPSON STRONG - TIE CO NEW PAINT GRADE CORNICE BOARD; SECURE TO WALL, BOTH ENDS. PAINT PNT-003.8"2" CEILING MOUNT SHEER 3/4" 1/4"8"2"V.I.F. EQEQ 1'-8" 4" 11 5/8" 4 3/8" STN-002 COUNTERTOP & BACKSPLASH WITH RECESSED SINK A500 4B 4C 4E A500 SIM 4D A500 SIM 4TH FLOOR 131' - 10" 3'-8 1/2" EQ 1'-6" EQ2'-10"4" EQ 1 1/2" EQ4" 4"WOOD PANEL WITH REVEAL, PLAM-001 OPEN SHELF, TYP. WOOD VENEER EQ EQ 9"ALIGN4" EQ 1 1/2"EQ 4" 4"2'-10"1'-7"1" 1/2" WOOD REVEAL, PLAM-001 WOOD PANEL, PLAM-001 STN-002 COUNTERTOP & BACKSPLASH W/RECESSED SINK MITERED CORNER, TYP. 3/4" PLYWOOD (EXT. GRADE) STN-002 COUNTERTOP & BACKSPLASH W/ RECESSED SINK 4" 4" EQ 1 1/2"EQ 4" CL1" CL 1" CLCL3/4"2'-10"STN-002 BASE WOOD PANELS, PLAM-001 CL 1" CL 1'-8" MITERED CORNER, TYP.3/4" PLYWOOD (EXT. GRADE) STN-002 COUNTERTOP & BACKSPLASH W/ SEMI- RECESSED SINK STN-002 BASE OPEN SHELVES ALL EXPOSED SURFACES TO BE FINISHED, TYP.4"4" CLEQ CL 1 1/2"CL EQ 4" CL 1" CL3/4" CL 1"2'-10"CL 1'-8" PLUMBING CHASE REMOVABLE PANEL 4" CLR REMOVABLE PANEL V.I.F.1'-8"4E A500 SIM4D A500 SIM V.I.F.V.I.F. MAINTAIN MAX. ALLOWABLE WIDTH AND DEPTH TO ACCOMODATE EXIST. PIPING 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:39:25 PMGUESTROOM MILLWORK DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A500 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/2" = 1'-0" DRAWING REF: A437b 2A PLAN - VANITY SCALE: 1/2" = 1'-0" DRAWING REF: 1 2B ELEVATION - VANITY SCALE: 1/2" = 1'-0" DRAWING REF: 12CSIDE ELEVATION - VANITY SCALE: 1/2" = 1'-0" DRAWING REF: A441 3A PLAN DETAIL - "PORTAL" SCALE: 1/2" = 1'-0" DRAWING REF: 1 3C ELEVATION - "PORTAL" SCALE: 1/2" = 1'-0" DRAWING REF: 1 3B ELEVATION - "PORTAL" SCALE: 1/2" = 1'-0" DRAWING REF: A442 5A PLAN -CUBBY SCALE: 1/2" = 1'-0" DRAWING REF: A500 6AELEVATION - CUBBY SCALE: 1" = 1'-0" DRAWING REF: A500 5C SECTION - CUBBY SCALE: 1" = 1'-0" DRAWING REF: 1 2D SECTION - VANITY SCALE: 1" = 1'-0" DRAWING REF: 13DSECTION - "PORTAL" SCALE: 1" = 1'-0" DRAWING REF: 1 2E SECTION - VANITY SCALE: 1 1/2" = 1'-0" DRAWING REF: A500 6C ELEVATION - VALANCE SCALE: 1" = 1'-0" DRAWING REF: A430 6B PLAN - VALANCE SCALE: 1/2" = 1'-0" DRAWING REF: A437a1CPLAN - ADA CLOSET @ CONDO SCALE: 1/2" = 1'-0" DRAWING REF: A5001BSECTION - ADA CLOSET @ CONDO SCALE: 1/2" = 1'-0" DRAWING REF: A437b1DPLAN - CLOSET SCALE: 1/2" = 1'-0" DRAWING REF: A4301ASECTION - CLOSET 1 08/25/2016 Revision 1 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 3" = 1'-0" DRAWING REF: A5001EVALENCE SECTION DETAIL COAT HOOKS SCALE: 1/2" = 1'-0" DRAWING REF: A453 4A PLAN - VANITY 4TH FLOOR SCALE: 1/2" = 1'-0" DRAWING REF: A0034BELEVATION - 4TH FLOOR VANITY 9 9 SCALE: 1/2" = 1'-0" DRAWING REF: A0034CSIDE ELEVATION - 4TH FLOOR 9 SCALE: 1" = 1'-0" DRAWING REF: 1 4D SECTION - VANITY SCALE: 1" = 1'-0" DRAWING REF: 1 4E SECTION - VANITY 9 SCALE: 1" = 1'-0" DRAWING REF: A453 5D PLAN - VANITY 4TH FLOOR 9 08/02/2017 01/11/18 REF 2'-10 1/2"1'-6 1/4"CLEQ EQA5013C 2C A501 2'-10" 40" MAX AFFREFLECTIVE SURFACE OF MIRROR2C A501 2'-10" 3/4"5" 2'-4 1/4" 4" 3/4"9" MIN8" MIN 11" MIN A604 3B SIM 4A A501 5B 6C A5013'-0" MIN CLR15 TREADS @ 11"12'-10"3'-0" MIN CLR 6A A501 2'-0"LEVEL WALL 42" AFF SLOPE WALL TO MATCH ANGLE OF STAIR, 42"H MEASURED FROM OUTSIDE EDGE OF TREAD 15 RISERS @ 6.67"8'-4"2x12 STRINGER w/ 5/8" GYP BD STORAGE 11"6 3/4" A501 5A A501 5B 15 TREADS @ 11" 12'-10" 3'-0" MIN 1'-0" 1'-0"3'-0"EDGE OF TREAD3'-0" FROMMETAL HANDRAIL, REF DETAIL 4C/A501 6A A501 11'-5 3/4" 2x12 STRINGER SOLID WOOD TREAD SOLID WOOD RISER 11 1/4"1/2" 11"6 3/4"EXISTING FLOOR STRUCTURE 2x4 THRUST BLOCK, SECURE TO FLOOR STRUCTURE FINISH FLOOR, REF. FINISH PLAN EXISTING FLOOR STRUCTURE 6 3/4"11" MODIFY EXISTING CEILING TO ACCOMMODATE STAIR 2x12 STRINGER FINISH STRINGER BEYOND 5/8" GYP BD 4"2'-6"3'-0"OPEN CUBBY OPEN CUBBY CL 1'-6" 1'-6" 3'-0" DOOR PANEL 1" OPEN CUBBIES, FINISH ON ALL EXPOSED SIDES HINGES EQEQ 3'-0"2'-0"3'-8"EXTEND SIDES OF UNIT TO MEET WALL 1'-10" V.I.F. PROVIDE CLOSET ROD AND SHELF 2'-4" V.I.F.1'-11 3/4" V.I.F.92'-0"4TH FLOOR 131' - 10" 5TH FLOOR 140' - 2" 4A A501 3'-0"3'-6"METAL HANDRAIL, REF DETAIL 4C/A501 METAL GUARDRAIL WITH METAL PICKETS @ 4" O.C. WALL AT GUARDRAIL HEIGHT SECURE STRINGERS TO WALL FINISH STRINGER TOP WALL WITH 3/4" SOLID WOOD STAINED TO MATCH STAIR A501 4C 3 1/2"3/4"1/4" 5/8" GYP BD 3/4" SOLID WOOD TRIM 3/4" SOLID WOOD TRIM, 42"H MEASURED FROM OUTSIDE EDGE OF TREAD METAL HANDRAIL ON METAL BRACKETS FOR SUPPORT, BLACK IRON 1 1/2"3/4"3 3/4"REF PARTITION TYPE 3/4" 5TH FLOOR 140' - 2"3 3/4" 3/4"3 3/4" 3/4" 2'-8 1/4" 3/4"1 1/2" 4" O.C. 1/4" DIA. METAL PICKETS SUPPORT POST BEYOND 3'-6"METAL GUARDRAIL, BLACK IRON FINISH FINISH FLOOR 1 3/4"3 3/4"4" O.C. TYP 3'-6"3/4" 2'-8 1/4" 3/4"3 3/4" 3/4"3 3/4" 3/4" 4'-0" 3/4" 3 3/4" 3 3/4" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:39:37 PMGUESTROOM MILLWORK DETAILS & CONDO STAIR DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A501 2211 N FRONTAGE RD, VAIL, COLORADO 81657 2 09/19/2016 CCD-002 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 SCALE: 3/4" = 1'-0" DRAWING REF: A4301CENLARGED PLAN - VAINTY SCALE: 3/4" = 1'-0" DRAWING REF: A501 3C ELEVATION - VANITY SCALE: 3/4" = 1'-0" DRAWING REF: A430 2C SECTION DETAIL - VANITY SCALE: 1/2" = 1'-0" DRAWING REF: A437a2AENLARGED PLAN - TYPICAL CONDO STAIR SCALE: 1/2" = 1'-0" DRAWING REF: A4434ASECTION - TYPICAL CONDO STAIR SCALE: 1 1/2" = 1'-0" DRAWING REF: A5015BENLARGED DETAIL SCALE: 1 1/2" = 1'-0" DRAWING REF: A501 5ASECTION - STAIR AT TOP SCALE: 1/2" = 1'-0" DRAWING REF: A448a1DELEVATION - VANITY SCALE: 3/4" = 1'-0"2D SECTION - VANITY SCALE: 3/4" = 1'-0" DRAWING REF: A447 3D PLAN DETAIL - DRY BAR SCALE: 3/4" = 1'-0" DRAWING REF: A4414DENLARGED PLAN DETAIL - CLOSET SCALE: 1/2" = 1'-0" DRAWING REF: A5016ASECTION DETAIL -TYP STAIR @ CONDO UNITS SCALE: 3" = 1'-0" DRAWING REF: A5014CSECTION DETAIL -TRIM @ STAIR WALL SCALE: 3/4" = 1'-0" DRAWING REF: A437a 6C SECTION DETAIL - RAILING SCALE: 3/4" = 1'-0"5C ELEVATION DETAIL - RAILING 08/02/2017 01/11/18 HEARTH BEYOND, POLISHED, DARK STAINED CONCRETE SLAB, TYP 1 x 8 R.S. CEDAR SHIPLAP PLANKS ON FURRING STRIPS RECESSED ACCESS DOOR, APPLY GYPSUM FINISH TO PANEL. PAINT TO MATCH ADJACENT FINISH 1 x 6 TONGUE AND GROOVE CEDAR GYP BD CEILING TO CONCEAL STRUCTUAL BEAM HEARTH BEYOND FIREBOX BEYOND 13' - 4" FINISH FLOOR EXISTING PRECAST STRUCTURAL WALL 2x8 WOOD PLATE STRUCTURAL STEEL BEAM T.O. STEEL BEAM 14' - 10 1/2" 2 1/2" METAL STUDS TO CLEAR B.O. BEAM 3 5/8" METAL STUDS 3 5/8" METAL STUD FLUE BEYOND STONE TILE, STN-003 1'-4"4'-3 1/2" 1'-0 1/2" CL FIREBOX BEYOND 1'-4" FIREPLACE INSERT 1 x 6 TONGUE AND GROOVE CEDAR BRACING FOR STRUCTURAL SUPPORT AS NECESSARY 3 5/8" METAL STUDS 5/8" CEMENT BOARD MESH AND ADHESIVE STONE TILE STN-003 1/4" CEMENTITIOUS FINISH ON MESH ON 3/4" PLYWOOD SUBSTRATE INSULATION AND FIREPROOFING PER FIREPLACE MANUFACTURER, MAINTAIN CLEARANCES 14" DIA FLUE, 18" CLEARANCE FROM ANY COMBUSTIBULES, EXTEND DIRECTLY BETWEEN EXISTING WOOD JOISTS, AVOID CONFLICT WITH STEEL BEAM REF MANUFACTURER FOR NECESSARY VENTING, COMBUSTION AIR INTAKE, GLASS COOLING INTAKES, CLEARANCES, PROPER INSTALATION AND OTHER NECESSARY MECHANICAL ITEMS. COORDINATE LOCATION WITH STRUCTURAL ENGINEER EXISTING STRUCTURAL COLUMN, ENSURE EXISTING LOCATION NOT HINDERING DESIGN, DO NOT PROCEED WITHOUT CONTACTING ARCHITECT IF CONFLICTING STONE BEYOND FIREPLACE INSERT GLASS, REMOVABLE, REF SHOP DRAWINGS TOP OF CONCRETE HEARTH REF SHOP DRAWINGS EXISTING METAL STUDS, BRACE FOR STRUCTURAL SUPPORT AS NECESSARY, SPECIALTY ENGINEER TO PROVIDE SIZE, GAUGE AND SPACING 3 5/8" METAL STUDS 5/8" CEMENT BOARD MESH AND ADHESIVE STONE TILE STN-003 EXISTING WOOD TRUSSES @ 24" O.C. REMOVABLE FRAME A502 6A A502 6B LIGHTBOX BEYOND, TYP MECHANICAL AIR DIFFUSER, REF SHEET M202 FOR DETAILS 1'-6" 1'-0" 1'-11 7/8" 4'-3 7/8" 1'-6" MIN CLR 2'-6" COORDINATE NECESSARY STRUCTURAL SUPPORT WITH STRUCTURAL ENGINEER 6'-0 3/4" COORDINATE NECESSARY STRUCTURAL SUPPORT WITH STRUCTURAL ENGINEER EXISTINGEXISTING STRUCTURAL COLUMN BEYOND BOTTOM OF FIREBOX OPENING TO MATCH TOP OF REMOVABLE FRAME (VERIFY HEIGHT)1'-4"1'-4"4'-10"NOTE: SEQUENCE OF FIREPLACE CONSTRUCTION SHALL BE: 1. CONSTRUCTION OF LOBBY SPACE 102 SIDE OF FIREPLACE INCLUDING HEARTH AND BASE CONCRETE BELOW FIREBOX 2. INSERT FIREBOX 3. CONSTRUCTION OF LOBBY SPACE 103 SIDE OF FIREPLACE INCLUDING HEARTH 4. COMPLETE CONSTRUCTION AND FINISHES 4'-3 3/4" 1'-0" 11 7/8" 1'-0 1/4" 1'-3 3/4" 1'-6 3/4" 6 1/4"ENGINEERED AIR DIFFUSER, REF MECAHNICAL, SHEET M202 FOR DETAILS 2'-0"2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 1'-4" 3" TYPBRACING AS NECESSARY 3 5/8" METAL STUDS 5/8" CEMENT BOARD MESH AND ADHESIVE STONE, STN-003 3 5/8" METAL STUDS, BRACE FOR STRUCTURAL SUPPORT AS NECESSARY EXISTING WOOD TRUSSES @ 24" O.C. 1/4" CEMENTITIOUS FINISH ON MESH, TOP, BOTTOM, AND EXPOSED SIDES 1'-1" 3" INFILL AREA 3/4" PLYWOOD SUBSTRATE ON TOP AND SIDES 2x4 FRAMING 1/4" PLYWOOD SUBSTRATE ON BOTTOM2'-0" TYP 3C A502 5C6C A502 A502 2E A502 2D A502 2B 10'-4" TO END OF PRECAST WALL OFFSET FLUE TO AVOID CONFLICT WITH COLUMN, 18" TOTAL CLEAR PATH AROUND 14" DIA FLUE, RUN DIRECTLY IN BETWEEN WOOD JOISTS (24" 0.C.) ABOVE FULLY ENCAPSULATE EXISTING CONCRETE STRUCTURAL COLUMN WITHIN FIREBOX, REF MANUFACTURER CUSTOM DETAILS 6A A502 6B A502 1'-6" 27'-0" 2'-3" 4'-2" 3'-6 3/4" 17'-1" 1'-10 1/4"3 3/8" 2'-9 5/8"4'-3 1/2"CUSTOM FIREBOX, OVERALL DIMENSIONS 8'-0" x 1'-7 3/4" 1'-2 1/2" 11 3/4"3"1'-3 3/4"1'-11 7/8" 11 7/8" 1'-6" FIREBOX FIREBOX 8'-0" 8'-0"FIREBOX6'-0 1/2" 2'-5 7/8" 1'-6 3/4"1'-1" 1'-3 3/4"11 7/8" 4'-3 1/2"9 3/4" 2 1/4"CL2" 10" SEALANT, TYP AT ALL INTERIOR CORNERS WHERE WOOD PLANK WALL MEETS STONE FIREPLACE MATERIAL 1x4 WOOD FURRING 2x6 R.S. CEDAR SHIPLAP PLANKS STONE, STN-003, MITER ALL OUTSIDE CORNERS 5/8" CEMENT BOARD 3 5/8" METAL STUDS SHIM AS NECESSARY EXISTING STRUCTURAL PRECAST WALL STRUCTURAL STEEL COLUMN, REF STRUCTURAL EXISTING STRUCTURAL COLUMN, ENSURE EXISTING LOCATION NOT HINDERING DESIGN, DO NOT PROCEED WITHOUT CONTACTING ARCHITECT IF CONFLICTING 1 5/8" METAL STUDS 3 5/8" METAL STUDS 5/8" CEMENT BOARD MESH AND ADHESIVE STONE TILE, STN-003 CONCRETE HEARTH 1/4" CEMENTITIOUS FINISH ON MESH ON 3/4" PLYWOOD SUBSTRATE ACCESS DOOR LATCH A502 2A EXISTING STRUCTURAL COLUMN, ENSURE EXISTING LOCATION NOT HINDERING DESIGN, DO NOT PROCEED WITHOUT CONTACTING ARCHITECT IF CONFLICTING ACCESS DOOR HINGE ATTACH RECESSED ACCESS DOOR TO METAL STUD ACCESS DOOR WITH GYB BD APPLIED AS FINISH MATERIAL TO PANEL, PAINT TO MATCH ADJACENT FINISH CAST-IN-PLACE CONCRETE BELOW, SOLID FILLED AND REINFORCED TO SUPPORT WEIGHT OF HEARTH REBAR SUPPORTS, RUN IN PERPENDICULAR DIRECTIONS, STRUCTURAL CONSULTANT TO ENSURE PROPER SUPPORT TY P R 0' - 0 3/4"TYPR 0' - 0 3/4"EXISTING STRUCTURAL COLUMN, ENSURE EXISTING LOCATION NOT HINDERING DESIGN, DO NOT PROCEED WITHOUT CONTACTING ARCHITECT IF CONFLICTING REINFORCED CONCRETE HEARTH CUSTOM FIREBOX INSULATED PANEL 3 5/8" METAL STUDS 5/8" CEMENT BOARD MESH AND ADHESIVE STONE TILE STN-003 LEAVE 1/8" GAP BETWEEN FRAM AND FINISH MATERIAL CUSTOM FIREBOX REMOVABLE FRAME CUSTOM FIREBOX REMOVABLE GLASS CAST-IN-PLACE CONCRETE VENEER WALL ON 3/4" PLYWOOD ON 3 5/8" METAL STUD, REINFORCE AS NECESSARY STRUCTURAL STEEL COLUMN, REF STRUCTURAL LEAVE 1/8" GAP BETWEEN FRAME AND ADJACENT FINISH MATERIAL REMOVABLE GLASS FOR FIREPLACE INSERT FIREPLACE INSERT INSULATED PANEL FIREPLACE INSERT BASE, REF MANUFACTURER CUSTOM DETAILS REINFORCED CAST-IN-PLACE CONCRETE SLAB HEARTH REINFORCED, CAST-IN- PLACE CONCRETE MESH AND ADHESIVE STONE, STN-003 EXISTING STRUCTURAL CONCRETE COLUMN BEYOND FINISH FLOOR, REF FINISH PLAN STONE BEYOND REMOVE CONCRETE AND EXTEND REBAR SUPPORTS INTO SLAB 1/8" MIN6"3 5/8"4"1'-0"1'-0" REINFORCED, CAST-IN- PLACE CONCRETE 3 5/8" METAL STUDS STONE TILE STN-003 1/4" CEMENTITIOUS FINISH ON MESH ON 3/4" PLYWOOD SUBSTRATE MESH AND ADHESIVE 5/8" CEMENT BOARD INSULATION AND FIREPROOFING PER FIREPLACE MANUFACTURER, MAINTAIN CLEARANCES STONE BEYOND REMOVABLE FRAME CUSTOM FIREBOX EXISTING CONCRETE STRUCTURAL COLUMN LEAVE 1/8" MIN GAP BETWEEN FIREBOX TRIM AND FINISH MATERIAL1/8" MIN7 1/8" 8" STRUCTURAL STEEL COLUMN, COORD. WITH STRUCTURAL 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:39:47 PMFIREPLACE DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A502 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/2" = 1'-0" DRAWING REF: A401bx3CSECTION - FIREPLACE SCALE: 1/2" = 1'-0" DRAWING REF: A401bx 5C SECTION - FIREPLACE SCALE: 1/2" = 1'-0" DRAWING REF: A401bx 6C SECTION - FIREPLACE SCALE: 1/2" = 1'-0" DRAWING REF: A401a5AENLARGED PLAN - FIREPLACE SCALE: 3" = 1'-0" DRAWING REF: A5022AENLARGED PLAN DETAIL - FIREPLACE @ WOOD WALL SCALE: 1 1/2" = 1'-0" DRAWING REF: A5022DPLAN DETAIL - FIREPLACE SCALE: 1 1/2" = 1'-0" DRAWING REF: A5022BPLAN DETAIL - FIREPLACE SCALE: 1 1/2" = 1'-0" DRAWING REF: A5022EPLAN DETAIL - FIREPLACE SCALE: 1 1/2" = 1'-0" DRAWING REF: A5026ASECTION DETAIL - HEARTH SCALE: 1 1/2" = 1'-0" DRAWING REF: A5026BSECTION DETAIL -HEAD 1 08/25/2016 Revision 1 2 09/19/2016 CCD-002 6 3/27/2017 RFI 73R1 Response 9 7/21/2017 CCD-005 9 9 9 9 9 9 08/02/2017 01/11/18 57 VA6015D 6D 4A A601 3D A4a A4a 4A A601 STONE COUNTER AND BACKSPLASH STN-001 9'-0"2'-4" 4" 1 1/2"2'-10"2'-6" EQ EQ BASE BEYOND STONE COUNTER AND BACKSPLASH STN-001 2'-10"2'-6" 1"4" 1 1/2"2'-4 1/2" 4A A601 EQ EQ WD-004 CL EQCLEQA606 6B SIM STONE COUNTER AND BACKSPLASH STN-001 1x6 CEDAR T&G PLANK CEILING 2'-7"2'-10" 4"3'-2"CL CL 30" BASE CABINET BASE AS SCHEDULED SEALANT STONE COUNTER AND BACKSPLASH STN-001 BASE BEYOND 2'-6"1" 4" 2'-4 1/2"2'-10"1 1/2"1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:07:02 PMMILLWORK - COFFEE BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A601 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 3/4" = 1'-0" DRAWING REF: A4062APLAN SCALE:3/4" = 1'-0"DRAWING REF: A601 5D ELEVATION SCALE:3/4" = 1'-0" DRAWING REF: A6013DELEVATION SCALE:3/4" = 1'-0"DRAWING REF:A4062CREFLECTED CEILING PLAN SCALE:1 1/2" = 1'-0" DRAWING REF: A601 4ASECTION SCALE:3/4" = 1'-0"DRAWING REF: A601 6D ELEVATION 108/25/2016Revision 1 9 7/21/2017CCD-005 1312/01/2017CCD-09 13 12/05/2017 01/11/18 D R D R STORAGE STORAGE STORAGE PASTRY STORAGE STORAGE GRAB-N-GO LOCKABLE WINE DISPLAY GRAB-N-GO LOCKABLE WINE DISPLAY MADE MARKET 105 A6026C 4A A602 TRANSACTION COUNTER 6A A406 A602 4E A602 6E 2'-3 3/8" 5C 5A A602 6A A602 3A A602 4A A602 5A A602 6A A602 2'-6" 1" CUP DISPENSER, TYP. STONE COUNTER STN-002 BASE AS SCHEDULED TRIM WIRE PULL FACE OF DOOR CHALKBOARD FINISH WOOD CABINET DOOR, FINISH TO MATCH PLASTIC LAMINATE SHELVING AND CABINET INTERIOR PLYWOOD CABINET CONSTRUCTION WITH PLASTIC LAMINATE FINISH PLYWOOD CABINET CONSTRUCTION WITH PLASTIC LAMINATE FINISH 2'-6"CHARRED WOOD 3/4" PLYWOOD 5/8" GYP BD, SHIM WHERE NECESSARY 3 5/8" METAL STUD T.O. COUNTER 5/8" GYP BD MADE MARKET WALL SLATTED SHELVES 3/4"x3/4" ALUMINUM REVEAL, XTREME TRIM OUTSIDE CORNER REVEAL X0CR34M, OR EQUIVALENT, MITER JOINTS WHERE VERTICAL AND HORIZONTAL REVEALS MEET5/8" GYP BD, SHIM WHERE NECESSARY F.R.P.PANEL T.O. STONE COUNTER STN-002 5/8" GYP BD 2 7/8" 1 1/2" 3 5/8" METAL STUD N 3A A602 BASE AS SCHEDULED PLYWOOD SHELVING WITH PLASTIC LAMINATE FINISH PLYWOOD SHELVING WITH PLASTIC LAMINATE FINISH 1 1/2" 1'-7 1/4" 3"STONE COUNTERTOP STN-002 1 3/4" WALL BEYOND 5/8" GYPSUM BOARD 8 3/16"10 3/16" 10 3/16" 5 1/2" 2'-10"ACRYLIC PASTRY DISPLAY UNIT BEYOND 1'-6"1 1/2" 7 5/8" 7 5/8" 7 5/8" 7 5/8" 6 7/8"1'-7 7/8" 3'-3" 3"10 1/8" 10 1/4" BASE AS SCHEDULED PLYWOOD SHELVING WITH PLASTIC LAMINATE FINISH PLYWOOD SHELVING WITH PLASTIC LAMINATE FINISH 1 1/2" 9 1/2"9 1/4" 1'-8 1/4"2'-1 7/8" 3'-4 1/8"REFRIGERATOR WALL AS SCHEDULED 2'-2 1/4"3"2'-5 1/4"6'-6 3/4"BASE AS SCHEDULED TRIM 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:07:13 PMMILLWORK - MADE MARKET THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS A602 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/2" = 1'-0"3D MADE MARKET - MILLWORK PLAN SCALE:1/2" = 1'-0"DRAWING REF: A602 6C ELEVATION A SCALE:1 1/2" = 1'-0" DRAWING REF: A602 4ASECTION SCALE: 3" = 1'-0"DRAWING REF: A6024EPLANDETAIL- MADE MARKET TRANSACTION COUNTER 108/25/2016Revision 1 109/15/2017CCD-006 1211/24/2017CCD-008 1312/01/2017CCD-09 SCALE: 3" = 1'-0"DRAWING REF: A4066EPLANDETAIL- MADE MARKET - ORDERING COUNTER SCALE:1/2" = 1'-0"DRAWING REF: A111 5C ELEVATION B SCALE:1 1/2" = 1'-0" DRAWING REF: A602 5A SECTION SCALE:1 1/2" = 1'-0" DRAWING REF: A602 6ASECTION SCALE:1 1/2" = 1'-0" DRAWING REF: A6023ASECTION 13 13 13 13 12 12/05/2017 01/11/18 4" 2'-4 1/2" 1 1/2"2'-10"4"2'-1" SCHEDULED BASE ADJUSTABLE PLAM SHELF STONE TOP AND SPLASHES STN-002 WIRE PULL 1'-6" PLAM SKIRT (REMOVABLE)2'-4" 2'-10"CL 4 1/2"8" MIN 1'-5" MIN 9" MIN 4"SOLID SURFACE COUNTER AND SPLASHES 6" HANDWASH SINK UNDERMOUNT FINISHED END PANEL SECURE PANEL TO ADJACENT WALLS OR SURFACES WITH REMOVABLE BRACKETSCL2'-0"2'-1"2'-4"8" MIN 9" MIN1'-5" MIN 1'-2" 2"PLAM COUNTER AND BACKSPLASH VALENCE UNDER CABINET LIGHT 1x4, PAINT BLACK PLAM SKIRT (REMOVABLE) 1" GYP BD SOFFIT WIRE PULL PLAM COUNTER AND BACKSPLASH VALENCE UNDER CABINET LIGHT 1x4, PAINT BLACK 2'-1" DISHWASHER SCHEDULED BASE GYP BD SOFFIT WIRE PULL 2"1'-4" 1'-2"2'-10" 2 1/4"1'-8" 1'-6" 1"1'-6"4"PLAM COUNTER AND BACKSPLASH VALENCE UNDER CABINET LIGHT 1x4, PAINT BLACK CL2'-1"4"6"PLAM DRAWER PLAM CABINET DOOR SCHEDULED BASE2'-10"4" 2'-0" ADJUSTABLE PLAM SHELF 1'-6" WIRE PULL GYP BD SOFFIT WIRE PULL 2"1" 1'-2" PLAM SKIRT (REMOVABLE)2'-4" 3/4"CL4 1/2"STONE COUNTER AND SPLASHES 6"2'-1" FINISHED END PANEL 8" MIN 1'-5" MIN 9" MINSECURE PANEL TO ADJACENT WALLS OR SURFACES WITH REMOVABLE BRACKETS 2'-1"4"2'-10"1'-0"1 1/2"PLAM COUNTER AND SPLASH PLAM SUPPORT @ MID POINT SCHEDULED BASE FINISH PLAM PANEL @ END 3'-6"2'-0"2E A6041'-7"1 1/2"1'-11 1/4" SEALANT, CONTINUOUS SOLID SURFACE PAINTED WOOD LEDGER GYP BD ON 3 5/8" MTL. STUDS SCHEDULED BASE +/- 2 1/2" FILLER 3'-0" 3'-0" 3'-0" 2'-6" 3'-0" 3'-0" 3'-0" 2B A604 4"2'-6" 4" SCHEDULED BASE ADJUSTABLE PLAM SHELF STONE TOP AND SPLASHES STN-002 WIRE PULL 2'-8 1/2" 1 1/2" 4"PLAM ON 3/4" PLYWOOD EDGE OF WALL BEYOND 2'-10"2'-7"2'-7 1/2"3'-8 7/8" 4 1/4"3'-4" 13'-8" 3 1/2" 5 5/16"2'-2 3/16" 18'-3 1/2" 4'-4 1/8" 3" DIAMETER STEEL PIPE COLUMN POST 3" DIAMETER STEEL PIPE COLUMN POST 1'-8 7/8" 10 5/8"5D A030 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:40:05 PMMILLWORK - BALLROOM, MEETING ROOM, BOARD ROOM, EMPLOYEE BREAKROOM, RESTROOM, AND GUEST LAUNDRY THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A604 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1 1/2" = 1'-0" DRAWING REF: A4032ASECTION - MEETING ROOM AND BOARDROOM COUNTER SCALE: 1 1/2" =1'-0" DRAWING REF: A4043ASECTION - LAVATORY @ EMPLOYEE LOCKER SCALE: 1 1/2" = 1'-0" DRAWING REF: A404 5A SECTION - EMPLOYEE BREAKROOM COUNTER @ SINK SCALE: 1 1/2" = 1'-0" DRAWING REF: A4046A SECTION - EMPLOYEE BREAKROOM COUNTER @ DISHWASHER SCALE: 1 1/2" = 1'-0" DRAWING REF: A404 4A SECTION - EMPLOYEE BREAKROOM COUNTER @ CABINETS SCALE: 1 1/2" = 1'-0" DRAWING REF:A4103BSECTION - LAVATORY @ PUBLIC RESTROOM SCALE: 1 1/2" = 1'-0" DRAWING REF:A4061DSECTION - COUNTER @ GUEST LAUNDRY SCALE: 1" = 1'-0" DRAWING REF: A404 2D PLAN -BENCH SCALE: 1 1/2" = 1'-0" DRAWING REF: A4042ESECTION - BENCH SCALE: 1" = 1'-0"6D ELEVATION - BALLROOM CREDENZA SCALE: 1 1/2" = 1'-0" DRAWING REF: A6042BSECTION - BALLROOM CREDENZA A410 1 08/25/2016 Revision 1 9 7/21/2017 CCD-005 SCALE: 1/2" = 1'-0" DRAWING REF: A4055EENLARGED PLAN - BALLROOM SLIDING POCKET WALL DIVIDER 9 08/02/2017 01/11/18 5A A605 3A A605 6A A605 6B A605 A605 2C A6055C A605 6C A605 3E 5E ACCESSIBLE COUNTER 3'-0" MIN CL2'-0"FACE OF WALL BELOW FACE OF GLASS BELOW EDGE OF COUNTER 2'-1" P.O.S. STATION 1 (LEFT) P.O.S. STATION 1 (RIGHT) P.O.S. STATION 2 P.O.S. STATION 3 OPEN BELOW FOR STORAGE COOKIE WARMER 1 1/2" MONITOR CUTOUT MONITOR CUTOUT MONITOR CUTOUT11"11" 8'-6 1/4" 5 3/4"14'-3 1/4"FACE OF WALL+/- 2" FROM3'-8"3'-0"T.O. COUNTER BEYOND FACE OF WALL BEYOND FACE OF WALL BEYOND EQ EQ T.O. COUNTER BEYOND EDGE OF GLASS +/-1/8" GAP BETWEEN GLASS PANELS BUTT CORNER EDGES OF GLASS, LEAVE +/- 1/8" GAP BETWEEN GLASS PANELS 1 1/2" 6'-0" 3'-0" FACE OF WALL BEYOND BUTT CORNER EDGES OF GLASS, LEAVE +/-1/8" GAP BETWEEN GLASS PANELS T.O. COUTNER BEYOND 2'-10" 10"3'-8"1 1/2" 9'-0" FACE OF WALL BEYOND CL 2'-10 1/2" T.O. COUNTER BEYOND 5A A605 6A A605 6B A605 3'-8"3'-0"FACE OF WALL BEYOND 1'-0 3/4" 1'-7 1/2"2'-10 1/2"1'-3 1/4" 1'-10 1/2"+/- 2'-8" TYPICAL P.O.S. STATION 4'-2"1'-7 1/2"1'-0 3/4" 1'-10 1/2" 1'-3 1/4" 1'-3 3/4" 2'-0 1/2"8 1/4"5 1/4" 1'-3 1/2" FLAT SCREN MONITOR BY OWNER LOCAKBLE CASH DRAWER WITH FULL EXTENSION GLIDES AND PULL COMPUTER CPU UNIT BY OWNER ON SHELF WITH FULL EXTENSION GLIDES - SOFT CLOSE TRASH CAN BY OWNER COMPUTER PRINTER BY OWNER LOCKABLE FILE DRAWER ON FULL EXTENSION DRAWER GLIDES W/ SOFT CLOSE. PROVIDE BRACKET HOLDER FOR HANGING FILES. TYPICAL P.O.S. STATION 4'-2" 3A A605 3'-8"3'-0"2'-0 1/2" 1'-3 3/4"3 1/4" 1'-3 1/2" 5 1/4"8 1/4"1'-9 1/2" ACCESSIBLE COUNTER 3'-0" MIN VENT SLOT COOKIE WARMER UNIT FLAT SCREN MONITOR BY OWNER LOCAKBLE CASH DRAWER WITH FULL EXTENSION GLIDES AND PULL COMPUTER CPU UNIT BY OWNER ON SHELF WITH FULL EXTENSION GLIDES - SOFT CLOSE TRASH CAN BY OWNER +/- 2'-9 1/4" 1 1/2"4" 5"2'-0" MODULE 4" 4 3/4" 3/4" DECORATIVE WALL COVERING 5/8" GWB 3 1/2" FRAMING 5/8" GWB 1/2" LAMINATED GLASS METAL WRAPPED MDF BASE 3/4" PLYWOOD 2x4 P.T. WOOD BASE FRAME METAL CLAD MDF ACCESSIBLE TRANSACTION TOP MELAMINE INTERIOR, PLASTIC LAMINATE EXTERIOR COOKIE WARMER UNIT VENT SLOT 6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING 1 3/4" 1 3/4" 2"2'-11 1/2" 2'-10 1/2"3'-0" 8" 8 1/4" 1 1/2"1'-9 1/2" 3 1/4" 2'-0" MODULE2"1 3/4"5"1 3/4" 4" 4 3/4" 11" METAL CLAD MDF TRANSACTION TOP 6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING 1/2" LAMINATED GLASS DECORATIVE WALL UPHOLSTERY 5/8" GWB 3 1/2" FRAMING 5/8" GWB METAL WRAPPED MDF BASE 3/4" PLYWOOD 2x4 P.T. WOOD BASE FRAME VENT SLOT TWO UTILITY DRAWERS WITH FULL EXTENSION GLIDES AND PULL METAL CLAD MDF COUNTER 10 1/2" DEEP REMOVABLE ANGLED PEDESTAL WITH 2 1/2" GROMMET FOR WIRE MANAGEMENT WIRE GROMMETS - 2 1/2" DIA. COOLING FAN REQUIRED. RECOMMEND COMAIRROTRAN MODEL WR2A1, GRAINGER STOCK 5C153 PROVIDE BRUSHED SS L BRACKET AT LOWER CUBBY EDGE CPU UNIT ON SHELF WITH FULL EXTENSION GLIDES. SHELF HAS SIDES ONLY, NO FRONT OR BACK. DATA (2 PORTS) AND QUAD AND DUPLEX OUTLETS BY OTHERS METAL CLAD MDF VERTICAL SURFACES OF MONITOR CUTOUT3'-0" 8"1 1/2" 1'-0 3/4" 1'-7 1/2" 1 1/2"4" 4 3/4"5" 1 3/4" 2'-0" MODULE 2 1/2" GROMMET DIRECTLY ABOVE QUAD OUTLET BELOW QUAD AND DUPLEX OUTLETS BY OTHERS WIRE GROMMETS - 2 1/2" DIA. PRINTER SHELF ON FULL EXTENSION DRAWER GLIDE. SHELF HAS SIDES ONLY, NO FRONT OR BACK. WOOD RAIL TO SUPPORT BRACKET FOR FILES LOCKABLE FILE DRAWER ON FULL EXTENSION DRAWER GLIDES. PROVIDE BRACKET HOLDER FOR HANGING FILES. METAL CLAD MDF TRANSACTION TOP 6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING 1/2" LAMINATED GLASS DECORATIVE WALL UPHOLSTERY 5/8" GWB 3 1/2" FRAMING 5/8" GWB METAL WRAPPED MDF BASE 3/4" PLYWOOD 2x4 P.T. WOOD BASE FRAME PRINTER2"1 3/4" METAL CLAD MDF COUNTER METAL CLAD MDF TRANSACTION TOP 6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING 1/2" LAMINATED GLASS DECORATIVE WALL UPHOLSTERY 5/8" GWB 3 1/2" FRAMING 5/8" GWB METAL WRAPPED MDF BASE 3/4" PLYWOOD 2x4 P.T. WOOD BASE FRAME 3'-8"4" 4 3/4" 5"2'-0" MODULE 1 1/2"8 1/4" 5 1/4" 1'-3 1/2" 3 1/4" VENT SLOT PARTIAL DOOR FOR ACCESS TO TRASH RECEPTACLE WITH SOFT CLOSE CONCEALED HINGES LOCKABLE CASH DRAWER WILL FULL EXTENSION GLIDES AND PULL TWO UTILITY DRAWERS WITH FULL EXTENSION GLIDES AND PULL2"1 3/4" 1 3/4" 11" METAL CLAD MDF COUNTER 10 1/2" DEEP REMOVABLE ANGLED PEDESTAL WITH 2 1/2" GROMMET FOR WIRE MANAGEMENT METAL CLAD MDF VERTICAL SURFACES OF MONITOR CUTOUT FINISH METAL PANEL WITH MITERED CUTS AT VISIBLE CORNERS OF CASEWORK USE MINIMUM NUMBER OF GLASS PANELS REQUIRED TO ACCOMMODATE LENGTH OF CASEWORK, ONE OR TWO PANELS PREFERABLE. PANELS WILL BUTT WITH +/- 1/8" GAP. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:18:02 PMMILLWORK - FRONT DESK THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A605 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 3/4" = 1'-0" DRAWING REF: A1112APLAN SCALE: 3/4" = 1'-0" DRAWING REF: A605 5C ELEVATION SCALE: 3/4" = 1'-0" DRAWING REF: A401a2CELEVATION SCALE: 3/4" = 1'-0" DRAWING REF: A605 6C ELEVATION SCALE: 3/4" = 1'-0" DRAWING REF: A6053ESERVICE SIDE ELEVATION SCALE: 3/4" = 1'-0" DRAWING REF: A6055ESERVICE SIDE ELEVATION SCALE: 1 1/2" = 1'-0" DRAWING REF: A6053ASECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A6055ASECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A605 6B SECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A605 6A SECTION NOT TO SCALE5BPERSPECTIVE NOTE: GRIND AND WELD ALL METAL EDGES 1 08/25/2016 Revision 1 10/17/2016 01/11/18 A606 3B A606 5D 5A A606 A606 3C A606 3D 3A A607 5B A606 5A A607 GLASS BELOW DIE WALL BELOW SS DRINK RAIL REFER TO FLOOR PLAN 4A/A401a REFER TO FLOOR PLAN 4A/A401a5'-0"5'-0" 4'-3" 5'-0" 4'-3" 5'-0" CL EQ EQ EQ EQ BAR EQUIPMENT BELOW 4'-0" ESPRESSO MACHINEBEER/WINE TAPS COUNTER BELOW SUPPORT AS NEEDED REVEAL, TYP. CABINET LIGHTING ABOVE END OF BAR TO MEET SURFACE OF PERPENDICULAR WALL, TURN EDGE OF METAL AND END APPROPRIATELY AT HIDDEN FACE, PROVIDE CLEAR SEALANT TO PREVENT TRAPPED WATER BETWEEN SURFACES F3a A4a A4a 2A A607 A606 6C A606 6C SIM EQ EQ CL 5" 10"10"1 1/2" 1 1/2"2" 2" 2" 2"EQ EQ EQ1 1/2" 1 1/2"1/4" STEEL T NOTES: 1. COLD-ROLLED STEEL AND PRIMED 2. COUNTERSINK BORE FOR 1/4" DIAMETER FASTNERS 5A A606 FOOTREST CONTINUOUS COUNTER, MITER ALL VISIBLE EDGES OF METAL 5B A606 DUPLEX RECEPTACLE FOOTREST USE MINIMUM NUMBER OF GLASS PANELS REQUIRED TO ACCOMMODATE LENGTH OF CASEWORK, ONE OR TWO PANELS PREFERABLE. PANELS WILL BUTT WITH +/- 1/8" GAP. USE MINIMUM NUMBER OF GLASS PANELS REQUIRED TO ACCOMMODATE LENGTH OF CASEWORK, ONE OR TWO PANELS PREFERABLE. PANELS WILL BUTT WITH +/- 1/8" GAP. 3A A607 5A A607 3'-6" 10'-6"REFER TO FLOOR PLAN 4A/A401a ENSURE OPENING FITS 60" TV 8'-0" MTL-01 1' REVEAL, TYP. POCKET FOR HINGED SLIDING DOORS, TYP. ESPRESSO MACHINE LIGHT COVE FOR LED STRIP LIGHTING BEYOND ENSURE OPENING FITS 60" TV ENSURE OPENING FITS 60" TV EQ1 EQ1 EQ1 EQ2 EQ22A A607 CONFIRM MILLWORK WILL CLEARSPRING POINT OF GLB BEYOND 13'-8 1/2"BAR EQUIPMENT 10" FIXED PANELALIGN ALIGN2'-3" FIXED PANEL CABINET DOOR CABINET PULL METAL WRAPPED MDF COUNTER 2 3/4" 1 1/2"1 1/2"1 3/4" 5A A606 EQUIPMENT 5B A606 DRINK RAIL CONTINUOUS COUNTER BAR MILLWORK BEYOND EDGE OF WALL GLULAM BEAM CEILING BAR MILLWORK BEYOND BASE REFER TO FINISH PLAN FOR WALL FINISH INFORMATION 3/4" MARINE GRADE PLYWOOD SECURED TO BAR DIE WALL METAL "T" BRACKET @ 32"OC - REFER TO DETAIL 3D/A606 3/4" MARINE GRADE PLYWOOD WITH FIBER REINFORCED PLASTIC PANEL, BLACK FINISH CLEAR SILICONE CAULK STAINLESS STEEL DRINK RAIL PRESSURE TREATED 2x MEMBER CHASE FOR PLUMBING/ ELECTRICAL1"MT-101 FOOTREST & ESCUTCHEON PLATE BEYOND DECORATIVE WALL UPHOLSTERY 10" +/- 9" 5" 5" 2'-5"2"6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING MOUNTED DIRECTLY TO BRACKET 1/2" LAMINATED GLASS METAL CLAD MDF COUNTER SURFACE FAB-10 METAL WRAPPED MDF BASE 3/4" PLYWOOD SURFACE MOUNTED CHANNEL TO ACCEPT GLAZING 1 3/4" 4" METAL CLAD MDF VERTICAL SURFACE BEYOND PURSE HOOK AT 30" O.C., MT-01 QUAD AND DUPLEX OUTLETS BY OTHERS FRP TRIM AS NECESSARY ELECTRICAL OUTLET (SIM ON OPP. WALL)2'-10"STEEL POSTS @ 4'-0" O.C. AND BOTTOM PLATE FOR SUPPORT 3/4" MARINE GRADE PLYWOOD SECURED TO BAR DIE WALL METAL "T" BRACKET @ 32"OC - REFER TO DETAIL 3D/A606 3/4" MARINE GRADE PLYWOOD WITH FIBER REINFORCED PLASTIC PANEL, BLACK FINISH CLEAR SILICONE CAULK STAINLESS STEEL DRINK RAIL PRESSURE TREATED 2x MEMBER CHASE FOR PLUMBING/ ELECTRICAL1" CL MT-101 FOOTREST & ESCUTCHEON PLATE DECORATIVE WALL UPHOLSTERY 9 3/4" CLCL +/- 9" 5" 5 1/4" 2'-5"2" 6mm x 15.2mm CHANNEL FOR LED STRIP LIGHTING MOUNTED DIRECTLY TO BRACKET 1/2" LAMINATED GLASS METAL CLAD MDF COUNTER SURFACE FAB-10 METAL WRAPPED MDF BASE 3/4" PLYWOOD 2x4 P.T. WOOD BASE FRAME SURFACE MOUNTED CHANNEL TO ACCEPT GLAZING 4"1 1/2" 4"3'-6" 5"METAL CLAD MDF VERTICAL SURFACE BEYOND PURSE HOOK AT 30" O.C., MT-01 QUAD AND DUPLEX OUTLETS BY OTHERS FRP TRIM AS NECESSARY STEEL POSTS @ 4'-0" O.C. AND BOTTOM PLATE FOR SUPPORT COUNTER BELOW METAL APPLIED MATERIAL PAINT WALL FACES BLACK 2 1/4"3" 1"3/4"3 5/8" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:18:11 PMMILLWORK - LOBBY BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A606 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/2" = 1'-0" DRAWING REF: A401a3APLAN SCALE: 1 1/2" = 1'-0"6ADETAIL - "T" BRACKET SCALE: 1/2" = 1'-0" DRAWING REF: A6063BELEVATION SCALE: 1/2" = 1'-0" DRAWING REF: A6063DELEVATION SCALE: 6" = 1'-0" DRAWING REF: A6016BDETAIL - CABINET PULL SCALE: 1/2" = 1'-0" DRAWING REF: A6063CELEVATION SCALE: 1/2" = 1'-0" DRAWING REF: A606 5D ELEVATION SCALE: 1 1/2" = 1'-0" DRAWING REF: A606 5B SECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A606 5ASECTION SCALE: 3" = 1'-0" DRAWING REF: A6066CPLAN DETAIL - REVEAL NOTE: GRIND AND WELD ALL METAL EDGES 1 08/25/2016 Revision 1 10/17/2016 01/11/18 WALL BEYOND WALL BEYOND LINEAR LED WALL WASH LIGHTING BRACING AS NECESSARY WALL BEYOND2 3/4"METAL CLAD MDF COUNTER 3'-6"BLOCKING AS REQUIRED IN METAL STUD WALL FOR SUPPORT (NOT SHOWN), KERF AS NECESSARY MTL-001 ON 3/4" PLYWOOD LAMINATE FINISH SIM WOOD BAR TRIM ABOVE BASE AS SCHEDULED METAL CORNER GUARD DOOR BEYOND BRACING AS NECESSARY CONFIRM MILLWORK WILL CLEARSPRING POINT OF GLB 13'-8 1/2"EXISTING TO REMAIN CEILING GLULAM BEAM BEYOND A606 6B 2'-7" 2'-0 1/2" EXISTING TO REMAIN WALL AND FINISH 30" BASE CABINET 2'-0 1/2" ADJUSTABLE SHELF3" WOOD TRIM, TYP. PAINT EXPOSED SURFACES OF REVEAL BLACK WALL BEYOND WALL BEYOND LINEAR LED WALL WASH LIGHTING BRACING AS NECESSARY BRACING AS NECESSARY FRY REGLET DRYWALL "Z" REVEAL DRMZ-25-25, OR EQUIVALENT, WHERE TEXTURED WALL FINISH AND METAL COUNTER MEET, TYP. 1/4" CEMENTITIOUS FINISH ON MESH, VERTICAL SIDES OF NICHE AND UPPER HORIZONTAL SURFACE TEXTURED WALL FINISH BEYOND WALL BEYOND DOOR BEYOND MOUNTING BRACKET AND TV, ALIGN FRONT FACE OF TV WITH FACE OF MILLWORK 1/4" CEMENTITIOUS FINISH ON MESH, VERTICAL SIDES OF NICHE, UPPER AND LOWER HORIZONTAL SURFACES3'-0 3/8"2 3/4"FRY REGLET DRYWALL "Z" REVEAL DRMZ-25-25, OR EQUIVALENT, WHERE TEXTURED WALL FINISH AND WOOD TRIM MEET, TYP.3" WOOD TRIM, TYP. 1" REVEALFRY REGLET DRYWALL "Z" REVEAL DRMZ-25-25, OR EQUIVALENT, WHERE TEXTURED WALL FINISH AND WOOD TRIM MEET, TYP. BEER/WINE TAPS CL LIGHT FIXTURES (2) 20" O.C. - SEE ELEC. DWG. FOR SCHEDULE AND DETAILS CL EQ EQ 4" METAL CLAD MDF COUNTER FIBER REINFORCED PLASTIC PANEL, BLACK FINISH 3'-6" 3'-0 5/8"3'-6"BAR EQUIPMENT6'-2 1/2"BLOCKING AS REQUIRED IN METAL STUD WALL FOR SUPPORT (NOT SHOWN), KERF AS NECESSARY TRIM BEYOND REVEL BEYOND MTL-001 ON 3/4" PLYWOOD 18"x24" RAKKS BRACKET AT 3'-0" O.C. EXISTING TO REMAIN CEILING GLULAM BEAM BEYOND 2'-7" 1'-9 1/8" 2'-0 1/2" 2'-0 1/2" EXISTING WALL AND FINISH 2'-0 1/2" METAL CLAD MODESTY PANEL 3 1/2"2 3/4"3" WOOD TRIM, TYP. 1" REVEALPAINT EXPOSED SURFACES OF REVEAL BLACK WALL BEYOND WALL BEYOND BRACING AS NECESSARY BLOCKING AS REQUIRED IN METAL STUD WALL FOR SUPPORT (NOT SHOWN), KERF AS NECESSARY DOOR BEYOND 1/4" CEMENTITIOUS FINISH ON MESH, VERTICAL SIDES OF NICHE, AND UPPER HORIZONTAL SURFACE FRY REGLET DRYWALL "Z" REVEAL DRMZ-25-25, OR EQUIVALENT, WHERE TEXTURED WALL FINISH AND WOOD TRIM MEET, TYP. 1/2" 5" 1/2" 1/2" 5" 1/2" 1'-0" 1/2" 5" 1/2" 1/2" 5" 1/2" 1'-0" GLASS SHELF, TYP. LED LINEAR LIGHT, SEE ELEC. DWGS PAINT ALL WOOD SURFACES MATTE WHITE, TYP. 1'-3 1/4"3'-6" 4 1/4"4 3/4" 1'-3" 4 1/4" 4 3/4" 1'-3" 4 1/4" 5 3/4" BRACING AS NECESSARY 1/4" CEMENTITIOUS FINISH ON MESH BEYOND WALL BEYOND METAL CLAD MDF COUNTER LINEAR LED WALL WASH LIGHTING MTL-001 ON 3/4" PLYWOOD FIBER REINFORCED PLASTIC PANEL, BLACK FINISH BAR EQUIPMENT 18"x24" RAKKS BRACKET AT 3'-0" O.C., CONFIRM NECESSARY STRUCTUAL SUPPORT EXISTING TO REMAIN CEILING GLULAM BEAM BEYOND 2'-7" 2'-0 1/2" EXISTING TO REMAIN WALL AND FINISH METAL CLAD MODESTY PANEL3 1/2"1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:18:15 PMMILLWORK - LOBBY BAR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS A607 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1 1/2" = 1'-0" DRAWING REF: A6062ASECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A606 5ASECTION SCALE: 1 1/2" = 1'-0" DRAWING REF: A606 3A SECTION 1 08/25/2016 Revision 1 10/17/2016 01/11/18 DN DN DN DN DN SD FF FSD J FSBSB SB SB JDD Dv DDv D vDDv DDD D D DDDDDD J KKKKT T T epoFFK 2.39 2.40 2.39 2.43 2.30 2.55 2.2 2.30 2.33 2.30 2.59 2.3 2.33 2.2 2.30 2.3 2.61 2.30 2.35 2.41 2.2 2.41 NOT IN SCOPE 2.3 2.43 2.3 2.3 2.43 2.30 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.50 2.2 2.43 2.43 2.3 2.2 2.30 2.44 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.62 2.2 2.30 2.3 2.3 2.43 2.43 2.3 2.3 2.43 2.48 2.3 2.55 2.50 2.58 2.52 2.48 2.3 2.30 2.43 2.3 2.43 2.60 2.30 2.30 2.17 2.30 2.43 2.11 2.48 2.2 2.2 2.46 2.43 2.2 2.30 2.30 2.3 2.3 2.30 2.2 2.42 2.30 2.30 2.3 2.39 2.39 2.39 2.3 2.43 2.30 2.17 2.43 2.3 2.17 2.30 2.43 2.3 2.16 2.17 2.16 2.17 2.43 2.3 2.32.43 2.30 2.3 2.30 2.43 2.16 2.16 2.3 2.60 2.3 2.43 2.3 2.22.43 2.17 2.78 2.16 2.3 2.3 2.30 2.30 2.3 2.17 2.64 2.63 2.63 2.63 2.65 2.47 2.62 2.622.62 2.11 2.48 2.33 2.43 2.30 2.30 2.30 2.2 2.3 2.48 2.41 2.51 2.2 2.59 2.11 2.11 GAS MAIN TRANS. GAS MAIN 2.30 2.2 2.41 2.84 2.85 2.89 2.89 2.39 2.43 2.3 2.30 2.41 2.22.2 2.2 13 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:07:23 PMDEMOLITION PLAN - 1ST FLOOR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS D111 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"DRAWING REF:A0306ADEMOLITIONPLAN-1ST FLOOR KEYNOTES 2.60 REMOVE TV'S GC TO COORDINATE LIQUIDATION WITH OWNER. 2.61REMOVE DEPRESSED LOBBY/LOUNGE AREA, PLANTERS, STAIRS, ETC. SEE STRUCTURAL FOR INFILL AND FLOOR LEVELING. 2.62 REMOVE FENCE AND GATES. 2.63 REMOVE LIGHTING CONTROLS. SEE ELECTRICAL DRAWINGS. 2.64 REMOVE AND REINSTALL ATM. 2.65 REMOVE ELECTRONIC ENTRY DOOR LOCK. 2.78 REMOVE STAIR AND RAILINGS. 2.84 REMOVE PORTION OF STONE PONY WALL. PATCH AND REPAIR TO MATCH ETR PONY WALL. 2.85 REMOVE CHAIR RAIL ON THE ENTRY WALL TO WEST SIDE CAFÉ. 2.89 REMOVE EXISTING FLOORING AND WALL PANELS AND PREPARE TO REPLACE. RESTORE CONTROL PANEL AND HANDRAILS TO LIKE NEW CONDITION. 2.42 REMOVE SPA. SEE STRUCTURAL FOR INFILL AND FLOOR LEVELING. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.44 REMOVE SAUNA. 2.46 REMOVE EXISTING STAIRS AND CONCRETE SLAB FOR RAMP INFILL. 2.47 REMOVE MIRROR. 2.48 REMOVE STORAGE AREA. 2.50 REMOVE STOREFRONT DOORS, FRAME, SIDELIGHTS, AND VESTIBULE STRUCTURE COMPLETELY. 2.51 REMOVE RAILING. 2.52 REMOVE PLUMBING FIXTURE. TERMINATE AND CAP PLUMBING. 2.55 REMOVE DOOR. 2.58 REMOVE ALL BATHROOM ACCESSORIES, INCLUDING TOILET PAPER HOLDERS, PAPER TOWELS DISPENSERS, GRAB BARS, ETC. 2.59 REMOVE TABLES, SEATING AND OTHER FURNITURE. GC TO COORDINATE LIQUIDATION WITH OWNER. 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.11 REMOVE SHELVING. 2.16 REMOVE ARTWORK, HANGERS, ETC AND TURNOVER TO OWNER. 2.17 REMOVE WALL MOUNTED LIGHTING. 2.30 REMOVE WALL PARTITION TO EXTENT SHOWN. 2.33 REMOVE MILLWORK INCLUDING ANY PLUMBING FIXTURES. 2.35 REMOVE REGISTRATION DESK. PATCH AND PREPARE ADJACENT SURFACES TO RECEIVE NEW FINISHES. 2.39 REMOVE STONE AND SALVAGE FOR REUSE. 2.40 REMOVE FIREPLACE WITH FLUES TO ROOF. PROTECT COPPER HOOD AND SALVAGE FOR REUSE. 2.41 CUT OPENING IN WALL IN PRECAST. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. GENERAL DEMOLITION NOTES 1. REFER TO SHEET A001 FOR COMPREHENSIVE GENERAL NOTES AND SYMBOL LEGEND. 2. AFTER REMOVAL OF FINISHES, FIXTURE, ETC DICTATED BY DEMOLITION NOTES, PATCH AND REPAIR AFFECTED SURFACES TO RECEIVE NEW. 3. REMOVE ROUND DOOR KNOBS THROUGHOUT HOTEL. 4 REMOVE HOLIDAY INN INTERIOR SIGNAGE. PATCH AND REPAIR DOORS AND WALLS FROM DEMO. 5 REPLACE THE ELECTRONIC KEY-CARD LOCK SYSTEM. INSTALL NEW OWNER SUPPLIED RFID/RADIO FREQUENCY IDENTIFICATION (CONTACT-LESS) LOCKS WITH NFC COMPATIBILITY. 6 REMOVE LIGHTING CONTROLS FROM THE PUBLIC AREAS. RELOCATE CONTROLS TO THE REGISTRATION DESK. EACH CONTROL RELOCATED IS TO BE COORDINATED WITH OWNER AND ARCHITECT ON AN INDIVIDUAL BASIS. SEE ELECTRICAL DRAWINGS. 7 WHERE TILE FLOORING IS DEMOLISHED, DEMO TILE BASE AS WELL. PREP FOR NEW BASE PER FINISH PLANS. 8 VERIFY EXISTING CONDITIONS AND DIMENSIONS IN FIELD. 9 INTERIOR DIMENSIONS ARE TO FINISHED FACE OF WALL. 10REFER TO ROOM NAMES/ TYPES ON OVERALL PLANS FOR CORRESPONDING ENLARGED PLANS. 108/25/2016Revision 1 310/07/2016ASI #1 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 12/05/2017 01/11/18 DN UP K1L 208 QQ1L 205 KAL 204 KS 201 K1L 228 K1L 238 K1R 236 K1R 234 K1L 232 K1R 230 K1R 226 K1L 224 K1R 222 K1L 220 K1R 218 K1L 216 K1R 214 K1L 212 K1R 210 KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 K3 206 KAR 203 K2 202 LAUNDRY 200 JANITOR 200B SEE ROOM 208 FOR SIMILAR DEMOLITION SEE ROOM 205 FOR SIMILAR DEMOLITION 2.3 2.43 A442 2A A432 2A A434 2A A441 2A A449 2A A431 2A A430 2A GUEST LAUNDRY 2.68 2.2 2.28 2.88 3 KS 301 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 K1L 316 K1R 314 K1L 312 K1R 310 K1L 308 QA 306 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 HOUSEKEEPING 300 SEE ROOM 208 FOR SIMILAR DEMOLITION SEE ROOM 205 FOR SIMILAR DEMOLITION 2.3 2.43 A435 2A A443 2A 2.68 2.2 2.28 2.88 3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:18:36 PMDEMOLITION PLAN - 2ND & 3RD FLOORS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS D112 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"6ADEMOLITION PLAN - 2ND FLOOR SCALE: 1/8" = 1'-0"6D DEMOLITION PLAN - 3RD FLOOR KEYNOTES 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.28 REMOVE OR RECONFIGURE ALL VENTS VISIBLE TO BOH. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.68 REMOVE LIGHTING. 2.88 REMOVE EXISTING WOOD BASE AND CHAIR RAIL. PATCH AND PREPARE SURFACES TO RECEIVE NEW FINISHES. 3 10/07/2016 ASI #1 10/17/2016 01/11/18 DW DN UPDWREF.DWREF.DWREF. HOUSEKEEPING 400 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412 Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434 DKL 436 Q1 438 KEXR 439 DKR 437 K4L 435 KKCON 433 K4L 431 KKCON 429 K4L 427 KKCON 425 K4L 423 KKCON 421 K4L 419 KKCON 417 K4L 415 KKCON 413 K4L 411 KKCON 409 K4L 407 KKCON 405 K4L 404 KCONR 403 KEXL 402 2.3 2.43 A448a 2A A447 2A A436 2A A446a 2AA444 2A SEE ROOMS 422 & 424 FOR SIMILAR DEMOLITION SEE ROOM 403 FOR SIMILAR DEMOLITION 2.66 2.2 2.28 2.88 A437a 2A SEE ROOMS 422 & 424 FOR SIMILAR DEMOLITION A451a 2A 9 A452 2A A453 2A 4E A122 3E A123 DKR+ 537 DKL+ 536 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 OPEN TO HOUSEKEEPING ELEVATOR SHAFT A448b 3B A446b 2A OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW SEE ROOM 524 FOR SIMILAR DEMOLITION SEE ROOM 503 FOR SIMILAR DEMOLITION SEE ROOM 524 FOR SIMILAR DEMOLITION A437b 2A 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/2/2017 5:40:26 PMDEMOLITION PLAN - 4TH FLOOR & LOFT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS D113 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: A4526ADEMO PLAN - 4TH PLAN SCALE: 1/8" = 1'-0" DRAWING REF: A5016DDEMO PLAN - 4TH FLOOR UPPER LEVEL/LOFT KEYNOTES 2.2 REMOVE DOOR, HARDWARE AND FRAME. 2.3 REMOVE FLOOR FINISH TO SUBFLOOR. 2.28 REMOVE OR RECONFIGURE ALL VENTS VISIBLE TO BOH. 2.43 REMOVE WALL FINISH TO SUBSTRATE. 2.66 REMOVE ACT CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.88 REMOVE EXISTING WOOD BASE AND CHAIR RAIL. PATCH AND PREPARE SURFACES TO RECEIVE NEW FINISHES. 3 10/07/2016 ASI #1 9 7/21/2017 CCD-005 9 08/02/2017 01/11/18 NOT IN SCOPE C EXIST C EXIST 14' - 8" A.F.F. SLOPED C EXIST 6' - 10" A.F.F. C EXIST 8' - 6 1/4" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 5 1/2" A.F.F. C EXIST 9' - 10" A.F.F. C EXIST 9' - 0" A.F.F. C EXIST 11' - 5 3/4" A.F.F. C EXIST 9' - 0" A.F.F. C EXIST 8' - 11 1/2" A.F.F. C EXIST 8' - 2" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 11 1/2" A.F.F. C EXIST 12' - 0" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 12' - 0" A.F.F.C EXIST 8' - 5 1/2" A.F.F. C EXIST 8' - 5 3/4" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 10" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 11' - 0" A.F.F. C EXIST 9' - 0" A.F.F. C EXIST 8' - 10" A.F.F. C EXIST 10' - 0" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 6" A.F.F. C EXIST 9' - 0" A.F.F. C EXIST 9' - 6" A.F.F. C EXIST 9' - 0" A.F.F. C EXIST 8' - 6 1/4" A.F.F. C EXIST 8' - 0" A.F.F. C EXIST 8' - 6" A.F.F. C EXIST 7' - 8" A.F.F. C EXIST 7' - 4" A.F.F. 2.68 2.66 2.66 2.662.66 2.66 2.66 2.66 2.66 2.66 2.67 2.66 2.672.67 C EXIST 11' - 0 1/4" A.F.F. 2.66 2.66 2.67 2.67 2.68 2.66 2.672.67 2.67 2.49 MASSAGE SPA SPRUCESTORAGESTORAGE STORAGE STORAGE STORAGE MECHANICALPOOL EQUIP. NOZAWA WC STOR. SPA SAUNA FITNESS STORAGE TELECOM ROOM LUGGAGE ROOM ELECTRICAL ELEV EQUIP EXIT PASSAGE STAIR EXIT PASSAGE SKI & BOOT STORAGE W WC OFFICE RECEPTION M WC LOBBY GM OFFICE SKI SHOP LIBRARY LOUNGE VEST. VEST. TIMBERLINE ROOM MASSAGE RECEPTION OFFICE DN C EXIST 8' - 0" A.F.F. C EXIST 7' - 8" A.F.F. C EXIST 8' - 6" A.F.F. C EXIST 7' - 8" A.F.F. C EXIST 8' - 6" A.F.F. 2.67 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:18:58 PMDEMOLITION PLAN - 1ST FLOOR REFLECTED CEILING THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS D121 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.49 SKYLIGHT TO REMAIN. 2.66 REMOVE ACT CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.67 REMOVE GYPSUM BOARD CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.68 REMOVE LIGHTING. SCALE: 1/8" = 1'-0" DRAWING REF: A1116ADEMOLITION PLAN - 1ST FLOOR REFLECTED CEILING PLAN 10/17/2016 01/11/18 KS 201 K1L 208 QQ1L 205 K1L 228 KAL 204 K1L 238 K1R 236 K1R 234 K1L 232 K1R 230 K1R 226 K1L 224 K1R 222 K1L 220 K1R 218 K1L 216 K1R 214 K1L 212 K1R 210 KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 K3 206 KAR 203 K2 202 LAUNDRY 200 CORRIDOR 240 C EXIST 8' - 0" A.F.F. 2.66 0" C EXIST 7' - 0" A.F.F.10" C EXIST 6' - 10" A.F.F. 2.66 2.27 2.672.17 2.80 2.80 2.68 2.81 2.82 HOUSEKEEPING 300 KS 301 QA 306K1L 308 K1R 310 K1L 312 K1R 314 K1L 316 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 CORRIDOR 340 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 C EXIST 8' - 0" A.F.F.10"0" C EXIST 7' - 0" A.F.F. C EXIST 6' - 10" A.F.F. 2.66 2.27 2.66 2.67 2.17 2.802.80 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:19:06 PMDEMOLITION PLAN - 2ND & 3RD FLOORS REFLECTED CEILING THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS D122 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.17 REMOVE WALL MOUNTED LIGHTING. 2.27 REMOVE WOOD SOFFITS. 2.66 REMOVE ACT CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.67 REMOVE GYPSUM BOARD CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.68 REMOVE LIGHTING. 2.80 RELOCATE ALL WIRING TO BATHROOMS. PULL SPRINKLER HEADS BACK TO WALL. 2.81 REMOVE EXISTING GYP. CEILING (OR ACT) 2.82 REMOVE EXISTING GYP. SOFFIT SCALE: 1/8" = 1'-0"6A DEMOLITION PLAN - 2ND FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0"6D DEMOLITION PLAN - 3RD FLOOR REFLECTED CEILING PLAN 1 08/25/2016 Revision 1 10/17/2016 01/11/18 REF. DKR+ 537 DKL+ 536 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 C EXIST 7' - 7" A.F.F.0"10" C EXIST 7' - 0" A.F.F. C EXIST 6' - 10" A.F.F. 2.66 2.27 2.66 HOUSEKEEPING 400 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412 Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434 DKL 436 Q1 438 KEX 439 DKR 437 K1L 435 KKCON 433 K1L 431 KKCON 429 K1L 427 KKCON 425 K1L 423 KKCON 421 K1L 419 KKCON 417 K1L 415 KKCON 413 K1L 411 KKCON 409 K1L 407 KKCON 405 K1L 404 KCONR 403 KEX 402 CORRIDOR 4402.67 2.17 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:19:12 PMDEMOLITION PLAN - 4TH FLOOR & LOFT REFLECTED CEILING THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS D123 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 2.17 REMOVE WALL MOUNTED LIGHTING. 2.27 REMOVE WOOD SOFFITS. 2.66 REMOVE ACT CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. 2.67 REMOVE GYPSUM BOARD CEILING TO EXTENTS SHOWN. REMOVE ALL LIGHTING AND DIFFUSERS. SCALE: 1/8" = 1'-0" DRAWING REF: A5016DDEMOLITION PLAN - 4TH FLOOR LOFT REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" DRAWING REF: A5016ADEMOLITION PLAN - 4TH FLOOR REFLECTED CEILING PLAN 1 08/25/2016 Revision 1 10/17/2016 01/11/18 SYMBOL DESCRIPTION DUPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT DUPLEX RECEPTACLE, SPLIT WIRED, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT SINGLE RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT GFCI RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM GFCI QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AND MOUNTING AS INDICATED BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE AND NUMBER OF CONDUCTORS, DASHED LINES INDICATE UNDER FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. INDICATES PHASE CONDUCTOR INDICATES NEUTRAL CONDUCTOR INDICATES GROUNDING CONDUCTOR NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MANUAL MOTOR STARTER MAGNETIC MOTOR STARTER COMBINATION STARTER/DISCONNECT MOTOR DUPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT FLOOR BOX, FLUSH FLOOR, WITH (2) DUPLEX RECEPTACLES AND SPACE FOR (2) SINGLE GANG TELECOMMUNICATION OUTLETS FLOOR BOX, POKE-THRU TYPE WITH (2) DUPLEX RECEPTACLES AND SPACE FOR TELECOMMUNICATION OUTLETS JUNCTION BOX SYSTEM FURNITURE CONNECTION, WALL AND FLOOR MOUNT PANELBOARD, SURFACE MOUNT PANELBOARD, RECESS MOUNT TRANSFORMER, DRY TYPE PLUG LOAD CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM DUPLEX RECEPTACLE, NEMA 5-20R, CEILING MOUNT, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SURFACE RACEWAY, DEVICES AS INDICATED PLUGMOLD, OUTLET EVERY 12" ON CENTER, ALTERNATE NEMA 5-15R RECEPTACLE WITH USB CHARGING PORT POWER LEGEND GENERAL DEMOLITION NOTES DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND EXISTING DRAWINGS. VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE. DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND NOT INDICATED FOR REUSE OR SALVAGE. MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE CIRCUITS AS REQUIRED DUE TO THE WORK. EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE WALL/FLOOR AND PATCH. REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE SOURCE. 1. 2. 3. 4. 5. 6. 7. LIGHTING LEGEND SYMBOL DESCRIPTION LIGHT FIXTURE LIGHT FIXTURE ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, WALL MOUNT LIGHT FIXTURE, WALL MOUNT, ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, POLE MOUNT EXIT SIGN, WALL MOUNT +90" AFF AND CEILING MOUNT, SHADED SIDE INDICATES FACE(S) OF SIGN, DIRECTIONAL CHEVRONS AS INDICATED EGRESS LIGHT WITH BATTERY PACK, WALL MOUNT +90" AFF OCCUPANCY SENSOR, DUAL TECHNOLOGY, CEILING MOUNT, OMNI-DIRECTIONAL AND DIRECTIONAL PHOTO CELL LIGHT SWITCH, 120/277-VOLT, 1HP RATED, MOUNT +46" AFF, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT LIGHT SWITCH, LOW VOLTAGE, MOUNT +46" AFF, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT ROOM CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM LOW VOLTAGE CABLING FOR LIGHTING CONTROL SYSTEM, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SYMBOL DESCRIPTION CCTV CAMERA KEYPAD, MOUNT +46" AFF,PROVIDE3/4" EMPTY CONDUIT TO ACCESSIBLEABOVECEILING SPACE CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE CARD READER WITH KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE MAGNETIC LOCK ELECTRIC STRIKE ELECTRIC LOCK GLASS BREAK SENSOR SECURITY LEGEND SYMBOL DESCRIPTION TELECOMMUNICATIONS OUTLET, MOUNT +18" AFF, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS OUTLET, FLUSH FLOOR MOUNT, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE SOUND SYSTEM SPEAKER, CEILING AND WALL MOUNT COAXIAL CABLE TELEVISION OUTLET, MOUNT +18" AFF INTERCOM STATION, MOUNT +46" AFF 19" EQUIPMENT RACK TELECOMMUNICATIONS OUTLET, CEILING MOUNT, PROVIDE 1" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS LEGEND GENERAL NOTES PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THE WORK. PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS: A. LIGHT FIXTURES B. PANELBOARDS / CIRCUIT BREAKERS C. SAFETY SWITCHES D. TRANSFORMERS E. WIRING DEVICES F. CONDUCTORS G. CONDUIT H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON DRAWINGS SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR EVALUATION. PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L. LABEL, AND LISTED FOR ITS INSTALLED APPLICATION. PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME MANUFACTURER. USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT MOUNTED DEVICES. ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS. PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS. IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED. PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE RATING ON THE MOTORS BEING INSTALLED. PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE HEATING, AIR CONDITIONING, OR REFRIGERATION EQUIPMENT. PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE BRANCH CIRCUITS. PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY. PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE FOR EACH PANELBOARD AFFECTED BY THE WORK. PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION. BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL. PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT. GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER OWNER ACCEPTANCE. PERFORM ALL WORK IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (2014) AND 2015 INTERNATIONAL BUILDING CODE. SEE ARCHITECTURAL TITLE SHEET T001 FOR ADDITIONAL CODE REQUIREMENTS. CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF (2015) FIRE PROTECTION CODE AND NFPA 241-2000 "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" ON SITE. NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE WATCH IN ACCORDANCE WITH FIRE PREVENTION CODE (2012), PARAGRAPH 901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO TIMES WHEN THE BUILDING IS NORMALLY UNOCCUPIED. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. SYMBOL DESCRIPTION FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN +96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN + 96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM MANUAL PULL STATION, MOUNT +46" AFF FIRE ALARM SMOKE DETECTOR, CEILING MOUNT FIRE ALARM HEAT DETECTOR, CEILING MOUNT FIRE ALARM DUCT SMOKE DETECTOR FIRE ALARM TAMPER SWITCH FIRE ALARM FLOW SWITCH FIRE ALARM PRESSURE SWITCH FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL MODULE FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED MAGNETIC DOOR HOLD OPEN DEVICE FIRE ALARM LEGEND 1P SINGLE POLE 2P DOUBLE POLE 3P THREE POLE 1PH SINGLE PHASE 3PH THREE PHASE A AMPERES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AMP AMPERE AUTO AUTOMATIC A/V AUDIO / VISUAL AWG AMERICAN WIRE GAUGE BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE C CONDUIT CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CF COMPACT FLUORESCENT CKT CIRCUIT C/T CURRENT TRANSFORMER CU COPPER DEMO DEMOLITION DISC DISCONNECT ELEC ELECTRICAL ELTG EXTERIOR LIGHTING EM EMERGENCY EQ EQUIPMENT FA FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FC FOOT CANDLE FT FEET FVNR FULL VOLTAGE NON-REVERSING G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTING GFI GROUND FAULT INTERRUPTING GND GROUND HP HORSE POWER IAW IN ACCORDANCE WITH ILTG INTERIOR LIGHTING IN INCHES KCMIL KILO CIRCULAR MILLS KVA KILO VOLT AMPS KW KILO WATTS KWH KILO WATT HOURS LED LIGHT EMITTING DIODE LTG LIGHTING LTS LIGHTS MCC MOTOR CONTROL CENTER MISC MISCELLANEOUS MTD MOUNTED MTR MOTOR N NEUTRAL NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NO. NUMBER P/BD PANELBOARD PR PRESENT TO REMAIN PRI PRIMARY PVC POLYVINYL CHLORIDE PWR POWER RCPT RECEPTACLE RL RELOCATED SEC SECURITY SW SWITCH SWBD SWITCH BOARD TELECOM TELECOMMUNICATIONS TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS W/ WITH XFER TRANSFER XFMR TRANSFORMER ABBREVIATIONS S S J SF SF T C C S SD H TS FS PS M C F F F KP CR M PC M M G S H S H S H PC I I I S H RATED WALL LEGEND SYMBOL DESCRIPTION NON-RATED PARTITION NON-RATED SMOKE RESISTIVE PARTITION 1 HOUR FIRE BARRIER 1 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 2 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 3 HOUR SMOKE COMPARTMENT BARRIER CK ML ES EL EXIST. 2000 MAIN 1200 100 EXIST. 100 400 EX 200 J LD 200A STEAMER 200A MECH RM GP 8.5 KVA LUGGAGE RM J B 3P-45A (4)#8, (1)#10 GND, 1β C. B 100A K 200A KITCHEN LLF 200A 400A BALLROOM STORAGE T 100A SHED 200A 100A 400A LLG POOL EQ. 100A 1200A SWBD EXIST. MAIN 3,000A SWBD EX. BUS TAP EX. WIREWAY 200A 200 NOTE 1 (4)#1/0, (1)#4 GND, 2β C. (4)#3, (1)#8 GND, 1-1/2β C. GENERAL NOTE 1. MAIN SWITCHBOARD LOAD (312 AMPS)AND REMOTE SWITCHBOARD LOAD (206 AMPS) HAS BEEN MEASURED IN THE FIELD. MAXIMUM DEMAND FROM HOLY CROSS ENERGY WAS RECORDED AT 174 KW (483 AMPS). 2. ALL NEW WIRE SHALL BE THHN. NOTE 1 PROVIDE (1) 3P-90A, (1) 3P-100A, (1) 3P-200A AND (1) 3P-400A CIRCUIT BREAKER W/IN EXISTING REMOTE SWITCHBOARD SECTION (1200A. 120/208V, 3PH, 4W, SN. SQUARE D "I-LINE"), MATCH EXISTING TYPE. NOTE 2 EXTEND EXISTING 200A FEEDER. NOTE 2 (4)#3/0, (1)#6 GND, 2-1/2β C. (4)#500 KCMIL, (1)#2 GND, 4β C. (4)#4/0, (1)#2 GND, 2-1/2β C. (4)#8, (1)#10 GND, 1β C. SMP 200A FUTURE SNOW MELT CONNECTIONS LIGHTING CONTROL PANEL (4)#4/0, (1)#2 GND, 2-1/2β C. RELOCATE 90 RTU-A1 3#4, 1#8 GND, 1-1/4" CONDUIT 200A 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/5/2017 4:16:48 PMLEGEND, SPECS, LIGHTING FIXTURE SCHEDULE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER MODEL VOLTAGE LAMPS INPUT WATTS MOUNTING COMMENTSQTY TYPE WATTS C1 FEELUX ELS203000K-120 120 1 LED 20 W 20 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR C2 FEELUX ELS103000K-120 120 1 LED 10 W 10 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR C3 VOLT LIGHTING GROUP PH3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR. C4 VOLT LIGHTING GROUP PL3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR C5 PHILIPS LEDALITE 24G8LCGAG1611EB 120 1 LED 17 W SURFACE PROVIDED BY CONTRACTOR WITH END CAPS C6 COMMERCIAL ELECTRIC 54261141 120 1 LED 30 W 32 SURFACE PROVIDED BY CONTRACTOR F1 PHILIPS DAY-BRITE 2TG20L8302FS12FUNV 120 1 LED 23 W 72 RECESSED PROVIDED BY CONTRACTOR. F1E PHILIPS DAY-BRITE 2TG20L8302FS12FUNVEMLED 120 1 LED 23 W 25 RECESSED PROVIDED BY CONTRACTOR FP1 VOLT LIGHTING GROUP CUSTOM SQUARE "PUCK" 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR. CONTACT VOLT LIGHTING GROUP L1 COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR. L1E COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP LTG-401 TECH LIGHTING PETRONA 700PTNA 120 22 LED 100 W 100 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. LTG-402 EUROFASE 20446-024 120 1 GU10 50 W 50 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. LTG-403 120 22 W PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. LTG-600 120 0 W SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. P1 COOPER LIGHTING S23DIP 2L30 TGRID 8 DD S1EM S93S 120 1 LED 11 PENDANT PROVIDED BY CONTRACTOR WITH REMOTE MOUNT EMERGENCY BACK-UP R1 PHILIPS LIGHTOLIER P6RD10NZ10UVB / P6RD830VB / P6RDCC 120 1 LED 7 W 10 RECESSED PROVIDED BY CONTRACTOR R1E PHILIPS LIGHTOLIER P6RD10NZ10UVBEM/ P6RD830VB / P6RDCC 120 1 LED 7 W 10 PENDANT PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP R2 PHILIPS LIGHTOLIER P6RD15NZ10UVB / P6RD830VB / P6RDCC 120 1 LED 12 W 16 RECESSED PROVIDED BY CONTRACTOR R2E PHILIPS LIGHTOLIER P6RD15NZ10UVBEM / P6RD830VB / P6RDCC 120 1 LED 12 W 16 RECESSED R3 PHILIPS LIGHTOLIER P6RD20NZ10UVB / P6RD830VB / P6RDCC 17 W R3E PHILIPS LIGHTOLIER P6RD20NZ10UVEMB / P6RD830VB / P6RDCC 120 1 LED 17 W 16 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP R4 PHILIPS LIGHTOLIER CP4RN / CP4RBO7830W 120 1 LED 11 W 11 RECESSED PROVIDED BY CONTRACTOR S1 SPA AREA WALL SCONCE SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. S2 PUBLIC RESTROOMS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. S3 GUESTROOM LOFTS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. SR1 NICOR D-SERIES DLR56 2709-120-3K-BL 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR FIXTURE TO BE BLACK AND DIMMING. SR2 LITHONIA 5G1MB LED M6 120 1 LED 11 W 15 RECESSED WALL WASHING, BLACK AND DIMMING. PROVIDED BY CONTRACTOR. X1 DUALLITE HCX X2 LITHONIA AFN DB X3 LITHONIA AFN DB FWD 0 W 1 8/25/2016 FOR CONSTRUCTION SET 4 11/07/2016 ASI #2 10 9/15/17 CCD-06 12 12/01/2017 CCD-08 13 12/01/2017 CCD-09 NOT TO SCALE3APARTIAL RISER DIAGRAM 12/05/2017 01/11/18 SD FFFF F FF FSD FJFFSBSB SB SB FJ FDD Dv D Dv D vDDv DD D D D DDDDDD JF FF K KKJ KT T T epoFFKF F FFJ MENSROOMWOMENSROOMMAINTENANCE FITNESS AREA N.I.C. N.I.C. TIMBER FRAME ENTRY STRUCTURE AND ROOF TO BE REMOVED 26.1 26.10 26.11 TYPICAL 26.12 26.12 26.2 26.2 26.13 26.3 26.14 26.3 26.14 26.12 26.2 26.3 26.14 EXISTING TO REMAIN PANEL 26.3 26.14 26.1226.3 26.12 26.14 RECEPTION DESK TO BE REMOVED 26.326.3 26.12 26.12 26.1526.15 26.4 26.3 26.3 26.15 26.16 BENCH SEATING TO BE REMOVED 26.3 26.17 26.3 26.14 26.12 26.3 26.14 26.3 26.14 26.12 RECEPTION DESK TO BE REMOVED 26.3 26.14 26.12 26.5 26.5 26.18 26.12THERAPY / SPA 26.5 26.12 26.18 26.5 26.18 26.12 26.5 26.18 26.12 26.5 26.5 26.12 26.12 26.15 26.3 26.19 26.19 26.20 26.20 HOT TUB TO BE REMOVED 26.3 26.2 26.21 26.22 26.3 26.14 26.12 SOFFIT TO BE REMOVED 26.5 26.1526.2 26.12 26.15 26.5 TYPICAL 26.24 26.23 26.6 COVE MOUNTED SPOT LIGHTING TYPICAL 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:02 AMDEMOLITION PLAN - 1st FLOOR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E101 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"6APOWER DEMOLITION PLAN - 1st FLOOR KEYNOTES 26.19 DISCONNECT AND REMOVE SAUNA STEAM GENERATOR AND ALL ASSOCIATED EQUIPMENT BACK TO SOURCE. CIRCUIT TO BE REUSED FOR NEW WORK. 26.20 DISCONNECT AND REMOVE HOT TUB PUMPS, ASSOCIATED EQUIPMENT AND CONTROLS. CIRCUITS TO BE EXTENDED REUSED FOR NEW HOT TUB LOCATION. 26.21 DISCONNECT AND REMOVE HVAC DISCONNECTS FOR RELOCATION. 26.22 DISCONNECT AND REMOVE ABANDONED MISCELLANEOUS ELECTRICAL DEVICES / CONDUIT/EQUIPMENT AND WIRE BACK TO SOURCE. 26.23 DISCONNECT AND REMOVE AHU FOR REPLACEMENT WITH NEW UNIT. 26.24 DISCONNECT AND REMOVE OUTDOOR CONDENSING UNITS, DISCONNECTS AND WIRE BACK TO SOURCE. CIRCUITS TO BE REUSED FOR NEW VAV BOXES. TYPICAL OF (3) 26.1 DISCONNECT AND REMOVE LIGHTING, CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW UNDER CANOPY LIGHTING. 26.2 DISCONNECT AND REMOVE LIGHTING. CIRCUIT TO BE REUSED FOR NEW LIGHTING IN SAME AREA. 26.3 DISCONNECT AND REMOVE ALL LIGHTING, SWITCHING AND WIRE BACK TO SOURCE. 26.4 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION ON NEW WALL. 26.5 DISCONNECT AND REMOVE LIGHTING AND SWITCHING. REMOVE WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW LIGHTING WORK IN THIS SAME AREA. 26.6 DISCONNECT AND REMOVE ALL WALL MOUNTED SCONCES, RECESSED LIGHTING ABOVE GUESTROOM DOORS AND IN VENDING AREA, ANY ASSOCIATED CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW LED RECESSED LIGHTING ALONG GUESTROOM CORRIDOR. 26.10 DISCONNECT AND REMOVE RECEPTACLE, CONDUIT AND WIRE BACK TO REUSABLE LOCATION. 26.11 DISCONNECT AND REMOVE INFRARED HEATER AND WIRE BACK TO REUSABLE LOCATION. HEATER AND CIRCUIT TO BE REUSED FOR NEW VALET LOCATION. 26.12 DISCONNECT AND REMOVE FIRE ALARM DEVICES AND WIRE BACK TO REUSABLE LOCATION. DEVICES TO BE REUSED FOR NEW WORK. 26.13 DISCONNECT AND REMOVE PANELBOARD AND FEEDER BACK TO SOURCE. LABEL BREAKER OR DISCONNECT AS SPARE. 26.14 DISCONNECT AND REMOVE ALL RECEPTACLES, DATA OUTLETS AND WIRE BACK TO SOURCE. 26.15 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO SOURCE. 26.16 DISCONNECT AND REMOVE RECESSED FLOOR BOXES, CONDUIT AND WIRE BACK TO SOURCE. 26.17 DISCONNECT FIRE PLACE FOR DEMOLITION / REMOVAL. 26.18 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW WORK IN THIS SAME AREA. GENERAL PLAN NOTES 1. REMOVE ALL SPEAKERS, SWITCHING AND ALL ASSOCIATED SOUND SYSTEM EQUIPMENT FROM THERAPY / SPA AND RETURN TO OWNER FOR REUSE IN NEW THERAPY / SPA LOCATION. 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 SDKS 201KMR 208 QQMR 205 K 228 KA 204 K 238 K 236 K 234 K 232 K 230 K 226 K 224 K 222 K 220 K 218 K 216 K 214 K 212 K 210 KARI 237 QQARI 235 QQ 233 QQ 231 QQ 229 QQ 227 QQ 225 QQ 223 QQ 221 QQ 219 QQ 217 QQ 215 QQ 213 QQ 211 QQ 209 QQ 207 K 206 K 203 KA 202 LAUNDRY 200 JANITOR 200B CORRIDOR 240 E434 3 26.626.6 26.6 KS 301 K 338 K 336 K 334 K 332 K 330 K 328 K 326 K 324 K 322 K 320 K 318 K 316 K 314 K 312 K 310 K 308 QA 306 QQ 339 QQ 337 QQ 335 QQ 333 QQ 331 QQ 329 QQ 327 QQ 325 QQ 323 QQ 321 QQ 319 QQ 317 QQ 315 QQ 313 QQ 311 QQ 309 QQ 307 QQ 305 QQ 304 QQ 303 QQ 302 HOUSEKEEPING 300 CORRIDOR 340 26.626.6 26.6 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:04 AM2nd AND 3rd FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E102 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"1 2nd FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLAN SCALE: 1/8" = 1'-0"2 3rd FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLAN KEYNOTES 26.6 DISCONNECT AND REMOVE ALL WALL MOUNTED SCONCES, RECESSED LIGHTING ABOVE GUESTROOM DOORS AND IN VENDING AREA, ANY ASSOCIATED CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW LED RECESSED LIGHTING ALONG GUESTROOM CORRIDOR. 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 HOUSEKEEPING 400 KCCON 401 QA 406 KCON 408Q 410 KCON 412 Q 414 KCON 416 Q 418 KCON 420 Q 422 KCON 424 Q 426 KCON 428 Q 430 KCON 432 Q 434 KCON 436 Q 438 KEX 439 KSCON 437 KEX 435 KSCON 433 KEX 431 KSCON 429 KEX 427 KSCON 425 KEX 423 KSCON 421 KEX 419 KSCON 417 KEX 415 KSCON 413 KEX 411 KSCON 409 KEX 407 KSCON 405 KEX 404 KSCON 403 K 402 CORRIDOR 44026.6 26.6 26.626.6 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:05 AM4th FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E104 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E4331 4th FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLAN KEYNOTES 26.6 DISCONNECT AND REMOVE ALL WALL MOUNTED SCONCES, RECESSED LIGHTING ABOVE GUESTROOM DOORS AND IN VENDING AREA, ANY ASSOCIATED CONDUIT AND WIRE BACK TO REUSABLE LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW LED RECESSED LIGHTING ALONG GUESTROOM CORRIDOR. 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 REF oc oc ocococSBSB SB SB D DDDD kpkp J DD D DDDD v v vvv voc oc M M oc ocM M M ococ3oc3oc M J JJ J J J JocJ J J J J J Joc J J J J J J J J MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 STORAGE 132 ENGINEER STORAGE 133 ENGINEER 134 EMPLOYEE BREAK ROOM 135 OFFICE 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 GAME ROOM109OFFICE 130 OFFICE 131 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN107EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOREQUIP113ROOM115TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 137 WOMEN'S BATHROOM 138 MEN'S BATHROOM 139 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S150CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 E401 1 E402 1 E403 1 E404 1 E404 2 E405 1 E406 1 E406 2 E402 3E402 5 W EMPLOYEE LOCKER ROOM 136 EXISTING PANEL TO REMAIN N.I.C. N.I.C. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:09 AM1st FLOOR PLAN - NEW LIGHTING THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E111 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"1 NEW LIGHTING PLAN - 1st FLOOR KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 SDKS 201KMR 208 QQMR 205 K 228 KA 204 K 238 K 236 K 234 K 232 K 230 K 226 K 224 K 222 K 220 K 218 K 216 K 214 K 212 K 210 KARI 237 QQARI 235 QQ 233 QQ 231 QQ 229 QQ 227 QQ 225 QQ 223 QQ 221 QQ 219 QQ 217 QQ 215 QQ 213 QQ 211 QQ 209 QQ 207 K 206 K 203 KA 202 LAUNDRY 200 JANITOR 200B CORRIDOR 240 KS 301 K 338 K 336 K 334 K 332 K 330 K 328 K 326 K 324 K 322 K 320 K 318 K 316 K 314 K 312 K 310 K 308 QA 306 QQ 339 QQ 337 QQ 335 QQ 333 QQ 331 QQ 329 QQ 327 QQ 325 QQ 323 QQ 321 QQ 319 QQ 317 QQ 315 QQ 313 QQ 311 QQ 309 QQ 307 QQ 305 QQ 304 QQ 303 QQ 302 HOUSEKEEPING 300 CORRIDOR 340 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:11 AM2nd AND 3rd FLOOR GUESTROOM CORRIDOR LIGHTING PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E112 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"1 2nd FLOOR GUESTROOM CORRIDOR LIGHTING PLAN SCALE: 1/8" = 1'-0"2 3rd FLOOR GUESTROOM CORRIDOR LIGHTING PLAN KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 HOUSEKEEPING 400 KCCON 401 QA 406 KCON 408Q 410 KCON 412 Q 414 KCON 416 Q 418 KCON 420 Q 422 KCON 424 Q 426 KCON 428 Q 430 KCON 432 Q 434 KCON 436 Q 438 KEX 439 KSCON 437 KEX 435 KSCON 433 KEX 431 KSCON 429 KEX 427 KSCON 425 KEX 423 KSCON 421 KEX 419 KSCON 417 KEX 415 KSCON 413 KEX 411 KSCON 409 KEX 407 KSCON 405 KEX 404 KSCON 403 K 402 CORRIDOR 440 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:13 AM4th FLOOR GUESTROOM CORRIDOR LIGHTING PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E114 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E4331 4th FLOOR GUESTROOM CORRIDOR LIGHTING PLAN KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 REF Ref.UnderCounter SBSB SB SB J J J J MEETING ROOM 127 BOARDROOM126POOL EQUIP145MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102VESTIBULE101SKI BOOT REMOVAL AREA 110 RETAIL 109 OFFICE 3 130OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN107EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOREQUIP113ROOM115TELECOMROOM117M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S150CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 N.I.C. N.I.C. W EMPLOYEE LOCKER ROOM 137 PR PR PR E401b 4A E402 4AE403 4A E404 4A E404 6C E405 6A E406 4A E406 3D E402 4C E402 6C LD B RELOCATED 100A PANEL 26.45 TYPICAL OFFICE 2 131 LLD +48" 26.105 TO EXISTING BALLROOM RECEPTACLE 26.39 LLF LLF- 1,3 LLF- 5,7 LLF- 9,11 LLF- 13,15 26.108 26.107 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:13:57 AM1st FLOOR PLAN - POWER AND COMMUNICATIONS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E121 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a6APOWERAND COMMUNICATIONS PLAN - 1st FLOOR KEYNOTES 26.39 PROVIDE MATCHING AIC 400A, 3P CIRCUIT BREAKER IN AVAILABLE 3000A SWITCHBOARD SPACE FOR NEW 400A PANEL 'LLF' TO BE LOCATED IN NEW STORAGE AREA AT MEETING ROOM. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.105 PROVIDE RECEPTACLE AND DATA OUTLET FOR DIGITAL EVENT READER. EXTEND RECEPTACLE TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. COORDINATE FINAL LOCATION AND REQUIREMENTS WITH APPROVED PROVIDER PRIOR TO ROUGH-IN. 26.107 PROVIDE 400A, 3ΗΎ, 42P PANEL. EXTEND AND CONNECT TO 3P BREAKER IN SWITCHGEAR WITH (4)#500KCMIL, (1)#2GND - 3 1/2"C. CONTRACTOR TO FIELD COORDINATE PANEL LOCATION SO THAT PANEL CAN BE USED FOR FUTURE DEVELOPMENT OF UPSTAIRS LODGING. 26.108 PROVIDE JUNCTION BOX OR SINGLE POINT CONNECTION FOR OUTDOOR INFRARED HEATERS. TYPICAL OF (4). 1 8/25/2016 FOR CONSTRUCTION SET 3 10/07/2016 ASI #1 5 12/07/2016 RFI #55 9 7/21/17 CCD-05 07/31/2017 01/11/18 HHHSDSDKS 201KMR 208 QQMR 205 K 228 KA 204 K 238 K 236 K 234 K 232 K 230 K 226 K 224 K 222 K 220 K 218 K 216 K 214 K 212 K 210 KARI 237 QQARI 235 QQ 233 QQ 231 QQ 229 QQ 227 QQ 225 QQ 223 QQ 221 QQ 219 QQ 217 QQ 215 QQ 213 QQ 211 QQ 209 QQ 207 K 206 K 203 KA 202 LAUNDRY 200 JANITOR 200B CORRIDOR 240 E430 3 E430 2E430 5 7 E430 8 E434 1 E434 4 E431 5 E431 7 KS 301 K 338 K 336 K 334 K 332 K 330 K 328 K 326 K 324 K 322 K 320 K 318 K 316 K 314 K 312 K 310 K 308 QA 306 QQ 339 QQ 337 QQ 335 QQ 333 QQ 331 QQ 329 QQ 327 QQ 325 QQ 323 QQ 321 QQ 319 QQ 317 QQ 315 QQ 313 QQ 311 QQ 309 QQ 307 QQ 305 QQ 304 QQ 303 QQ 302 HOUSEKEEPING 300 CORRIDOR 340 E430 9 9 E431 10 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:20 AM2nd AND 3rd FLOOR PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E122 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"1 2nd FLOOR PLAN - POWER SCALE: 1/8" = 1'-0"2 3rd FLOOR PLAN - POWER KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 DW HOUSEKEEPING 400 KCCON 401 QA 406 KCON 408Q 410 KCON 412 Q 414 KCON 416 Q 418 KCON 420 Q 422 KCON 424 Q 426 KCON 428 Q 430 KCON 432 Q 434 KCON 436 Q 438 KEX 439 KSCON 437 KEX 435 KSCON 433 KEX 431 KSCON 429 KEX 427 KSCON 425 KEX 423 KSCON 421 KEX 419 KSCON 417 KEX 415 KSCON 413 KEX 411 KSCON 409 KEX 407 KSCON 405 KEX 404 KSCON 403 K 402 CORRIDOR 440 E430 11 E431 1 E432 1 3 E432 4 E432 7 E433 1 KSCON+ 537 KCON+ 536 KCON+ 532 KSCON+ 533 KSCON+ 529 KSCON+ 525 KSCON+ 521 KSCON+ 517 KSCON+ 513 QQCON+ 509 QQCON+ 505 QQCON+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCON+ 512 KCON+ 508 K+ 501 3 E431 4 E432 5 E433 3 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:25 AM4th AND 5th FLOOR PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E123 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E4331 4th FLOOR PLAN -POWER SCALE: 1/8" = 1'-0" DRAWING REF: E43325th FLOOR PLAN -POWER KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 SBSB SB SB CRDL DLCREWH-1 N.I.C. N.I.C. 26.51 AHU-5 EF-06 26.52 EF-05 MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 DISHWASHING 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 OFFICE 3 130OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN107EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOREQUIP113ROOM115TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 W EMPLOYEE LOCKER ROOM 137 CORRIDOR 125 OFFICE 2 131 26.47 CU-5 26.48 26.52 P1 J26.49 EF-7 EF-8 26.45 26.45 26.50 LLD B LIGHTING CONTROL PANEL EWH-2 B- 8,10 BOH BD LLF BOH- 7,9 K EWH-1 EF-9 RTU-A1 KEF-1 MUA-1 26.117 B-16,18 K- 2,4,6 (3) #4 (1) #8GND 1-1/4" C. 26.126 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/5/2017 4:16:51 PM1st FLOOR PLAN - MECHANICAL POWER THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E131 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.50 FIELD VERIFY FINAL LOCATION FOR PUMP P1' PRIOR TO ROUGH-IN. CONNECT TO AVAILABLE 15A 3P 208V CIRCUIT OR PROVIDE MATCHING AIC 15A 3P CIRCUIT BREAKER IN AVAILABLE SPACES AS NEEDED. COORDINATE OVER CURRENT WITH HVAC CONTRACTOR AND PROVIDE AS REQUIRED. PROVIDE MOTOR STARTER / DISCONNECT PER NAMEPLATE DATA AND LOCATE AT/ON PUMP. 26.51 PROVIDE 2P 50A MATCHING AIC CIRCUIT BREAKER IN AVAILABLE SPACES. PROVIDE (2) #8, (1) #10 - 3/4" C. AND CONNECT TO NEW EWH-1. 26.52 CONNECT FAN TO LIGHTING CIRCUIT AHEAD OF LOCAL SWITCHING SO AS TO REMAIN ON AT ALL TIMES. 26.117 EXTEND ORIGINAL CIRCUIT MADE AVAILABLE DURING DEMOLITION. MAKE SINGLE POINT CONNECTION. VERIFY WIRE AND BREAKER SIZE AND PROVIDE NEW AS REQUIRED. 26.126 TO NEW 3P-90A CIRCUIT BREAKER IN EXISTING REMOTE SWITCHBOARD SECTION. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.47 CONNECT TO AVAILABLE 15A 3P 208V CIRCUIT BREAKER OR PROVIDE MATCHING AIC 15A 3P CIRCUIT BREAKER IN AVAILABLE SPACES AS NEEDED. 26.48 PROVIDE MATCHING AIC 60A 3P CIRCUIT BREAKER IN AVAILABLE SPACES. EXTEND CIRCUIT AND FEED EQUIPMENT WITH (3) #6, (1) #10GND - 1"C. 26.49 FIELD VERIFY FINAL LOCATION FOR VAV CONTROL TRANSFORMER PRIOR TO ROUGH-IN. CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. SCALE: 1/8" = 1'-0"DRAWING REF:E401a6A1st FLOOR PLAN - MECHANICAL POWER 1 8/25/2016 FOR CONSTRUCTION SET 9 7/21/17 CCD-05 10 9/15/17 CCD-06 13 12/01/2017 CCD-09 12/05/2017 01/11/18 FSBSB SB SB FFFCMVVVFFFF FF FF FVVVV FFFFFFV VV VFFFF G H J K L M N O M1 MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 GM OFFICE 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 STORAGE 132 ENGINEER STORAGE 133 ENGINEER 134 EMPLOYEE BREAK ROOM 135 OFFICE 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101SKI BOOT REMOVAL AREA 110 GAME ROOM 109 OFFICE 130 OFFICE 131 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 137 WOMEN'S BATHROOM 138 MEN'S BATHROOM 139 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 W EMPLOYEE LOCKER ROOM 136 CORRIDOR 125 PR N.I.C. N.I.C. PR 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:29 AM1st FLOOR PLAN - NEW FIRE ALARM THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E141 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES SCALE: 1/8" = 1'-0"1 1st FLOOR PLAN - FIRE ALARM 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 F FF FFFSD SDSD SD SD SD SD SD SD 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:30 AM2nd, 3rd AND 4th FLLOR PLANS - TYPICAL FIRE ALARM THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E142 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"1 TYPICAL GUESTROOM CORRIDOR FIRE ALARM PLAN KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 07/31/2017 01/11/18 FFCMVV FF FV N O M1 usb horiz usb horiz +48" +48" +60" +54" PR PR 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:33 AMENLARGED FLOOR PLAN - LOBBY / LOUNGE / BAR POWER THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E401a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1211 ENLARGED FLOOR PLAN - LOBBY/LOUNGE/BAR KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 D D D DD D D J DD D DDDD v v vv v vF F FFococVVFococVVFoc ocFV V oc ocFFV VJ K R5a R5a R5a R5 R5 R5 R5 R5 R5 R5 R5 R5 R5R5 R5 R5 R5R5 R5 R5 R5 R5 ROOM 120 ROOM 121 ROOM 122 CORRIDOR 119B MASSAGE/ SPA WAITING 119 ROOM 124 ROOM 123 J 7 E402 M M1 M M1 H WOMEN'S BATHROOM 138 MEN'S BATHROOM 139 H J 1'-7 7/8" 1'-6 5/8" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:36 AMENLARGED PLANS - SPA / THERAPY AND PUBLIC RESTROOMS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E402 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1111 ENLARGED REFLECTED CEILING PLAN - SPA / THERAPY SCALE: 1/4" = 1'-0" DRAWING REF: E1212ENLARGED FLOOR PLAN - SPA / THERAPY SCALE: 1/4" = 1'-0" DRAWING REF: E1113LIGHTING PLAN - PUBLIC RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF: E1214ENLARGED PLAN - PUBLIC RESTROOMS SCALE: 1/4" = 1'-0" DRAWING REF:E1115NEWLIGHTING PLAN - 1st FLOOR - Callout 1 SCALE: 1/4" = 1'-0" DRAWING REF: E1216POWERAND COMMUNICATIONS PLAN - 1st FLOOR - Callout 1 SCALE: 1/2" = 1'-0" DRAWING REF: E402 7 SPA ELEVATOION DETAIL KEYNOTES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 kpkp J M Ref.Under CounterV J J MH ZONE ZONE BOARDROOM 126 MEETING ROOM 127 ZONE ZONE CONNECT TO CORRIDOR LIGHTING CIRCUIT & CONTROLS CONNECT TO CORRIDOR LIGHTING CIRCUIT & CONTROLS 26.31 26.31 R2 R4 R4 TYPICAL TYPICALR2 R4 R4R4 R4 R4 R2 R2 R2 R2 26.33 L1 L1E L1 P1 R4 ZONE ZONEZONE R2E R2E R2E R2E R2E R2E R2E G H H H40"40" PR H40" PR PR PR BOARDROOM 126 MEETING ROOM 127 26.45 26.45 26.4526.45 26.53 PR 26.4526.59 48"48"26.105 26.105 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:06 AMENLARGED PLANS - MEETING ROOMS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E403 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1112ALIGHTING PLAN -MEETING ROOMS SCALE: 1/4" = 1'-0" DRAWING REF: E1214A POWER AND COMMUNICATIONS PLAN - MEETING ROOMS KEYNOTES 26.31 PROVIDE NEW LIGHTING CONTROLS / PANEL EQUAL TO LUTRON GRAFIK EYE QS. 26.33 PROVIDE RECESSED JUNCTION BOXES AND LIGHTING CIRCUIT THRU NEW LIGHTING CONTROLS. INSTALL PENDANT LIGHTING SUPPLIED BY OTHERS AND MAKE ALL FINAL CONNECTIONS. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.53 SAWCUT / TRENCH AND REPAIR FLOOR AS REQUIRED. PROVIDE RECESSED FLOORBOX / POWER AND RECEPTACLES FOR MILLWORK / FURNITURE. COORDINATE FINAL LOCATION WITH ARCHITECTS DRAWINGS. 26.59 PROVIDE POWER TO RECESSED MOTORIZED SCREEN AS ADD / ALTERNATE. 26.105 PROVIDE RECEPTACLE AND DATA OUTLET FOR DIGITAL EVENT READER. EXTEND RECEPTACLE TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. COORDINATE FINAL LOCATION AND REQUIREMENTS WITH APPROVED PROVIDER PRIOR TO ROUGH-IN. 1 8/25/2016 FOR CONSTRUCTION SET 5 12/07/2016 RFI #55 6 1/09/2017 CCD-03 9 7/21/17 CCD-05 07/31/2017 01/11/18 oc oc ococ REFoc ococ F V VFFFoc F V VFFFF G OFFICE 130 OFFICE 131 OFFICE 129 OFFICE 128 G H ENGINEER 134 EMPLOYEE BREAK ROOM 135 W EMPLOYEE LOCKER ROOM 136 M EMPLOYEE LOCKER ROOM 137 EF-02 26.52 F G F G H 1 A 2 34 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® TOWN OF VAIL USE 7/11/2016 11:09:40 AMENLARGED PLANS - BACK OF HOUSE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 07/08/16 - PERMIT SET E404 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1111 ENLARGED REFLECTED CEILING PLAN - BACK OF HOUSE SCALE: 1/4" = 1'-0" DRAWING REF: E1112ENLARGED REFLECTED CEILING PLAN - EMPLOYEE BREAKROOM AND LOCKER ROOMS SCALE: 1/4" = 1'-0" DRAWING REF: E1213ENLARGED FLOOR PLAN - BACK OF HOUSE SCALE: 1/4" = 1'-0" DRAWING REF: E1214ENLARGED FLOOR PLAN - EMPLOYEE BREAKROOM & LOCKER ROOMS KEYNOTES 26.52 CONNECT FAN TO LIGHTING CIRCUIT AHEAD OF LOCAL SWITCHING TO REMAIN ON AT ALL TIMES 07/11/2016 P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 3ocJJ J J kpMFFFV J M BALLROOM/ MEETING ROOM 104 MEETING STORAGE 153 C1 C2 C1 C2C1 C1 C2 C1 C1 C1 C1 C1 C1 C1 C1 C1 C2 C2 C2C2 C1C1 C1C1 C1C1 C2 C1 C1 C1 C1 C1 C1 C1 C1C1 C2C2 C2 C1 C1 C1 C2C1 C1 C1 C2 C2 C1C1 C1C1 C1C1 C2 C1 C1 C1 C2 C1 C1 C1 X1 F1 F1 F1 R1 R1E R1 R1E R1 R1 R1E R1 R1E R1R1 R1R1 R1E R1 R1E R1 R1 R1E ZONE 1 ZONE 2 26.31 ZONE 3 26.45 26.31 LTG-403 LTG-403 LTG-403 LTG-403 26.58 LLF MOTORIZED SCREEN SWITCH +42" +42" +42" PR PR PR BALLROOM/ MEETING ROOM 104 MEETING STORAGE 153 26.54 26.45 B- 2 B- 4B- 6 MOUNT RECEPTACLES HORIZONTAL B- 23 26.31 BD 26.45 26.59 26.107 LLF 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:10 AMENLARGED PLANS - BALLROOM THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E405 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1113ALIGHTING PLAN - BALLROOM SCALE: 1/4" = 1'-0" DRAWING REF: E1216APOWERAND COMMUNICATIONS PLAN - BALLROOM KEYNOTES 26.31 PROVIDE NEW LIGHTING CONTROLS / PANEL EQUAL TO LUTRON GRAFIK EYE QS. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.54 SAWCUT / TRENCH AND REPAIR FLOOR AS REQUIRED. PROVIDE RECESSED FLOORBOX WITH RECEPTACLES. CONNECT TO EXISTING RECEPTACLE CIRCUIT OR AVAILABLE 20A 1P 120V BREAKER. 26.58 PROVIDE JUNCTION BOXES AND LIGHTING CIRCUIT THRU NEW LIGHTING CONTROLS. INSTALL PENDANT LIGHTING SUPPLIED BY OTHERS AND MAKE ALL FINAL CONNECTIONS. 26.59 PROVIDE POWER TO RECESSED MOTORIZED SCREEN AS ADD / ALTERNATE. 26.107 PROVIDE 400A, 3ΗΎ, 42P PANEL. EXTEND AND CONNECT TO 3P BREAKER IN SWITCHGEAR WITH (4)#500KCMIL, (1)#2GND - 3 1/2"C. CONTRACTOR TO FIELD COORDINATE PANEL LOCATION SO THAT PANEL CAN BE USED FOR FUTURE DEVELOPMENT OF UPSTAIRS LODGING. 1 8/25/2016 FOR CONSTRUCTION SET 4 11/07/2016 ASI #2 9 7/21/17 CCD-05 Notes: Total Est. Demand... 69 A Total Conn. Current: 69 A Total Est. Demand: 24800 VA Total Conn. Load: 24800 VA Power 20000 VA 100.00% 20000 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 79 A 79 A 55 A Total Load: 9100 VA 9100 VA 6600 VA 41 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 42 39 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 40 37 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 38 35 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 36 33 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 34 31 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 32 29 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 30 27 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 28 25 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 26 23 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 24 21 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 22 19 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 20 17 SPARE 20 A 1 0 VA 0 VA -- -- SPACE ONLY 18 15 250... 0 VA -- -- SPACE ONLY 16 13 OUTDOOR PATIO INFRARED HEATER 35 A 2 250... 0 VA -- -- SPACE ONLY 14 11 250... 0 VA -- -- SPACE ONLY 12 9 OUTDOOR PATIO INFRARED HEATER 35 A 2 250... 0 VA -- -- SPACE ONLY 10 7 250... 0 VA -- -- SPACE ONLY 8 5 OUTDOOR PATIO INFRARED HEATER 35 A 2 250... 160... 6 3 250... 160... 4 1 OUTDOOR PATIO INFRARED HEATER 35 A 2 250... 160... 3 40 A PANEL 'T LOCATED IN DUMPSTER SHED 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: Surface Wires: 4 Mains Rating: 400 A Supply From: Phases: 3 Mains Type: Location: MEETING STORAGE 153 Volts: 120/208 Wye A.I.C. Rating: VERIFY Branch Panel: LLF 07/31/2017 01/11/18 oc3J FVFF3F J L R2E R2E R1E R2 R2R2 R2 R2 R2 R2 R2 R2E R2 R2 R2 R3 R3 R3 R3 R3R3 R3ER3 R1 R3 R3 R3 R3R3E R3R1E R1 R1 26.43 26.43 26.43 26.44 26.44 26.44 CONNECT TO CORRIDOR LIGHTING CIRCUIT GUEST LAUNDRY 147 FITNESS CENTER 148 R4 R4 R4 26.43 26.43 N 26.43 MADE MARKET 105 R1 R1 R1 R1E R1 R1 R1 (2) BOH LIGHTING KEYPADS TO OFFICE LIGHTING CIRCUIT GP-10 VIA LIGHTING CONTROLS L +44" +44" HYDRATION STATION +42" +12" +12" FITNESS CENTER 148 GUEST LAUNDRY 147 LLD- 1,3 LLD- 2,4 LLD- 5 LLD- 9 LLD- 17 LLD- 15 LLD- 13 +86" LLD- 11 +86" EWC LLD- 7 LLD- 26 N SEE DRAWING A-602 AND K-101 FOR HEIGHTS AND ADDITIONAL INFORMATION MADE MARKET 105 LLD- 20 +12" +48" +48" +12" +48" +48" +72" +18" +48" +48" +48" +48" +12" 26.123 26.123 K- 32 K- 34 K- 36 K- 38 K- 40 K- 42 K- 44 K- 46 K- 52,54 CONNECT TO CKT B-14 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/5/2017 4:16:54 PMENLARGED PLANS - FITNESS, GUEST LAUNDRY AND MADE MARKET THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E406 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0"DRAWING REF: E1112ALIGHTING PLAN - FITNESS & G. LAUNDRY SCALE: 1/4" = 1'-0"DRAWING REF: E1112DLIGHTING PLAN - MADE MARKET SCALE: 1/4" = 1'-0" DRAWING REF: E1214APOWER AND COMMUNICATIONS PLAN - FITNESS AREA SCALE: 1/4" = 1'-0"DRAWING REF: E1213DPOWER PLAN - MADE MARKET KEYNOTES 26.43 CONNECT AHEAD OF SWITCHING AS NIGHT LIGHT. 26.44 PROVIDE CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. 26.123 CONNECT TO NEXT AVAILABLE 1P-20A CIRCUIT IN RELOCATED PANEL 'B'. UPDATE PANEL INDEX ACCORDINGLY. 1 8/25/2016 FOR CONSTRUCTION SET 9 7/21/17 CCD-05 10 9/15/17 CCD-06 13 12/01/2017 CCD-09 12/05/2017 01/11/18 33GGDD D CWOD D D J J J J J J J J J J J J J KITCHEN 151 DISHWASHING 106 B K K- 14 26.66 26.67 26.120 26.65 B K K- 17 34" 48" 60" KITCHEN 151 K- 1 K- 5 K- 9 K- 8 K- 19 K- 21 K- 23 K- 25 K- 27 K- 31 K- 33 K- 35 K- 37 K- 39 K- 28,30 K- 47,49,51 K- 41,43,45 26.114 26.115 26.116 B- 12 +12" B- 14 K- 53 +12" +12" 26.118 +4" +12" +4"48" K- 48 +12" 108" 108" 108" 108" ROOF ROOF 108" 108" +48" +48" +48" +48" +48" 26.123 26.123 26.123 K- 13 K- 29 +12" +48" 26.123 +4" 26.125 26.125 26.125 26.124 26.124 26.121 26.121 26.12226.122 +48" K- 16,18,20 K- 22,24,26 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/5/2017 4:16:58 PMENLARGED KITCHEN DETAILS AND PANELBOARD SCHEDULE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E407 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 KEYNOTES 26.65 PROVIDE 2X4 LAY-IN LIGHTING EQUAL TO LITHONIA 2ALT4 5000LM MVOLT. 26.66 PROVIDE 2X2 LAY-IN LIGHTING EQUAL TO ETI 54309141. 26.67 PROVIDE 1X2 LAY-IN LIGHTING EQUAL TO PIXI FLT12R27MD1622A. 26.114 PROVIDE SINGLE POINT CONNECTION AT 14" AFF TO DISH MACHINE CONTROL PANEL. FEED WITH (3) #10, (1) #10 GND-3/4" CONDUIT AND FLEXIBLE CONNECTION. 26.115 PROVIDE SINGLE POINT CONNECTION AT 14" AFF TO DISH MACHINE BOOSTER HEATER. FEED WITH (3) #3, (1) #8 GND- 1 1/4"C. 26.116 PROVIDE POWER TO MENU BOARD. VERIFY CONNECTION TYPE AND HEIGHT IN FIELD. 26.118 CONTRACTOR TO INTERCONNECT (2) TABLE MOUNTED HEAT LAMPS. 26.120 PROVIDE SINGLE POLE SWITCHING FOR EXHAUST HOOD FAN AND LIGHTS AT 54" AFF. MAKE FINAL CONNECTIONS. 26.121 COORDINATE LIGHT CONNECTION REQUIREMENTS WITH COOLER/FREEZER VENDER PRIOR TO ROUGH-IN. 26.122 CONDENSING UNIT(S) ARE REMOTELY MOUNTED ON LOW ROOF. PROVIDE FUSED DISCONNECT AND ASSOCIATED 120V GFCI/WP RECEPTACLE. 26.123 CONNECT TO NEXT AVAILABLE 1P-20A CIRCUIT IN RELOCATED PANEL 'B'. UPDATE PANEL INDEX ACCORDINGLY. 26.124 MOUNT RECEPTACLE ON EQUIPMENT STUB UP 4" FROM FINISH FLOOR WITH JUNCTION BOX. 26.125 STUB-UP 4" AFF FOR JUNCTION BOX/RECEPTACLE. SCALE:3/8" = 1'-0"DRAWING REF: E1113AENLARGED KITCHEN LIGHTING PLAN SCALE:3/8" = 1'-0"DRAWING REF: E1216AENLARGED KITCHEN POWER PLAN Notes: Kitchen Equipment - Non-Dwelling Unit 42700 VA 65.00% 27755 VA Receptacle 20600 VA 74.27% 15300 VA Total Est. Demand... 192 A Power 21188 VA 100.00% 21188 VA Total Conn. Current: 248 A Other 1580 VA 100.00% 1580 VA Total Est. Demand: 69103 VA Lighting 460 VA 100.00% 460 VA Total Conn. Load: 89348 VA HVAC 2820 VA 100.00% 2820 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 261 A 237 A 250 A Total Load: 31.1 kVA 28.5 kVA 29.7 kVA 53 KITCHEN FIRE SUPPRESSION 20 A 1 1.2 1.4 54 51 0.7 1.4 2 20 A MADE MARKET 105 - KIOSK EXPRESSO MACHINE 52 49 0.7 0.0 1 0 A SPARE 50 47 COOLER CONDENSING UNIT (ON ROOF)15 A 3 0.7 1.2 1 20 A KITCHEN 151 - KITCHEN OVEN CNTRL 48 45 0.8 1.9 1 20 A MADE MARKET 105 - KIOSK ATM 46 43 0.8 1.5 1 20 A MADE MARKET 105 - KIOSK FRIDGE 44 41 FREEZER CONDENSING UNIT (ON ROOF)15 A 3 0.8 0.7 1 20 A MADE MARKET 105 - KIOSK WINE... 42 39 COOLER EVAPORATOR COIL 15 A 1 1.5 1.1 1 20 A MADE MARKET 105 - KIOSK FREEZER 40 37 WALK-IN FREEZER LIGHTS 20 A 1 1.8 1.5 1 20 A MADE MARKET 105 - KIOSK FRIDGE 38 35 WALK-IN COOLER LIGHTS 20 A 1 1.8 1.8 1 20 A MADE MARKET 105 - KIOSK TOASTER 36 33 KITCHEN 151 - PREP TABLE 20 A 1 1.8 1.8 1 20 A MADE MARKET 105 - KIOSK LIGHTS 34 31 KITCHEN 151 - HEATED CABINET 20 A 1 1.8 1.8 1 20 A MADE MARKET 105 - KIOSK FRIDGE 32 29 KITCHEN 151 - ICE MACHINE 20 A 1 1.8 1.3 30 27 KITCHEN 151 - WORK TOP 20 A 1 0.8 1.3 2 20 A FREEZER EVAPORATOR COIL 28 25 KITCHEN 151 - PIZZA REF 20 A 1 1.6 8.0 26 23 KITCHEN 151 - PREP TABLE 20 A 1 1.6 8.0 24 21 KITCHEN 151 - STOCK POT KETTLE 20 A 1 1.8 8.0 3 90 A DISHMACHINE BOOSTER HEATER 22 19 KITCHEN 151 - STOCK POT KETTLE 20 A 1 1.8 3.7 20 17 KITCHEN 151 - HEAT LAMP / TABLE 20 A 1 1.6 3.7 18 15 SHUNT TRIP -- -- 0.0 3.7 3 40 A DISHMACHINE 16 13 EXHAUST HOOD 20 A 1 1.9 0.5 1 20 A KITCHEN LIGHTING 14 11 SHUNT TRIP -- -- 0.0 0.0 1 20 A SPARE 12 9 KITCHEN 151 - REF EQUIPMENT STAND 20 A 1 0.9 0.0 1 20 A SPARE 10 7 SHUNT TRIP -- -- 0.0 1.6 1 20 A KITCHEN 151 - PREP TABLE 8 5 KITCHEN 151 - CONV. OVEN 20 A 1 1.2 0.9 6 3 SHUNT TRIP -- -- 0.0 0.9 4 1 KITCHEN 151 - CONV. OVEN 20 A 1 1.2 0.9 3 15 A MAU-1 LOCATED ON ROOFTOP 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: Surface Wires: 4 Mains Rating: 200 A Supply From: LLF Phases: 3 Mains Type: Location: KITCHEN 151 Volts: 120/208 Wye A.I.C. Rating: Branch Panel: K 12/05/2017 01/11/18 FFJ SDHFJ FSDFJ FSDJ FFJ FFJ SD F FSD F FJ F FSD SD F FJ 26.81 26.8226.84 26.84 26.85 26.81 26.86 26.82 26.91 26.93 26.94 26.92 26.95 26.96 26.90 26.96 K2 202 26.81 26.82 26.84 26.84 26.85 26.81 26.87 26.88 26.86 26.82 K2 202 26.91 26.92 26.93 26.94 26.95 26.96 RELOCATED FAN BY OTHERS 26.96 26.90 26.81 26.82 26.84 26.86 26.85 26.84 26.81 26.91 26.92 26.93 26.94 26.95 26.96 26.90 26.81 26.82 26.8626.81 26.85 26.84 26.84 26.91 26.93 26.95 26.94 26.96 26.90 26.92 QA 306 26.81 26.82 26.84 26.81 26.82 26.86 26.85 26.84 QA 306 26.95 26.94 26.91 26.92 26.93 26.96 26.96 26.90 QA 406 26.81 26.81 26.82 26.84 26.86 26.85 26.84 QA 406 26.91 26.92 26.93 26.94 26.96 26.95 26.96 26.90 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:27 AMENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E430 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1021AGUESTROOM DEMOLITION - KA (204) SCALE: 1/4" = 1'-0"2A GUESTROOM NEW WORK - KA (204) SCALE: 1/4" = 1'-0"3A GUESTROOM DEMOLITION - K (202) SCALE: 1/4" = 1'-0" DRAWING REF: E1024AGUESTROOM NEW WORK - K (202) SCALE: 1/4" = 1'-0" DRAWING REF: E1025AGUESTROOM DEMOLITION - KARI (237) SCALE: 1/4" = 1'-0"6AGUESTROOM NEW WORK - KARI (237) KEYNOTES 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.87 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE LOCATION. LIGHTING FIXTURE AND CIRCUIT TO BE REUSED. 26.88 DISCONNECT AND REMOVE RECESSED FAN. FAN TO BE REUSED AT NEW LOCATION IN SAME AREA. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT. SCALE: 1/4" = 1'-0"1CGUESTROOM DEMOLITION - QQARI (235) SCALE: 1/4" = 1'-0" DRAWING REF: E1022CGUESTROOM NEW WORK - QQARI (235) SCALE: 1/4" = 1'-0" DRAWING REF: E1023CGUESTROOM DEMOLITION - QA RM (306) SCALE: 1/4" = 1'-0"4C GUESTROOM NEW WORK - QA RM (306) SCALE: 1/4" = 1'-0" DRAWING REF: E1045CGUESTROOM DEMOLITION - QA (406) SCALE: 1/4" = 1'-0"6C GUESTROOM NEW WORK - QA (406) 9 7/21/17 CCD-05 07/31/2017 01/11/18 DWREF. F SD DWREF. 33SDFJ J REFJ J F SD REFSD F J KCONL 412 Q1 410 26.81 26.81 26.85 26.85 26.86 26.82 KCONL 412 Q1 410 26.98 26.98 26.93 26.92 26.90 26.96 KCONL+ 512 26.86 KCONL+ 512 26.90 K1L 208 26.86 26.86 26.85 26.84 26.81 K1L 208 26.94 26.9526.95 26.100 +32" 26.90 26.93 QQ1L 205 26.86 26.81 26.84 26.85 26.86 QQ1L 205 26.94 26.91 26.90 26.95 26.86 26.81 26.84 26.84 26.82 26.85 26.86 26.94 26.91 +32" 26.96 26.95 26.100 26.90 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:36 AMENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E431 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.82 DISCONNECT AND REMOVE FIRE ALARM DEVICE FOR REUSE. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.96 RELOCATE FIRE ALARM DEVICE AT 80" AFF. EXTEND AND RECONNECT. 26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF. EXTEND AND RECONNECT AS 3-WAY. 26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. SCALE: 1/4" = 1'-0" DRAWING REF:E1041AGUESTROOM DEMO -KING CONDO (412) & QA SCALE: 1/4" = 1'-0"3A GUESTROOM NEW WORK - KING CONDO (412) & KA SCALE: 1/4" = 1'-0" DRAWING REF: E1044AGUESTROOM DEMOLITION - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E1046AGUESTROOM NEW WORK - KING CONDO LOFT (512) SCALE: 1/4" = 1'-0" DRAWING REF: E1021CDEMO -KING MODEL ROOM (208) SCALE: 1/4" = 1'-0"2C NEW WORK - KING MODEL ROOM (208) SCALE: 1/4" = 1'-0"3C DEMOLITION - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0"4C NEW WORK - QQ MODEL ROOM (205) SCALE: 1/4" = 1'-0" DRAWING REF: E1025CGUESTROOM DEMOLITION - KS (301) SCALE: 1/4" = 1'-0"6C GUESTROOM NEW WORK - KS (301) 9 7/21/17 CCD-05 07/31/2017 01/11/18 REFJ DWREF.DWREF. J REF J KEXR 439 26.86 26.81 26.84 26.85 26.86 KEXR 439 26.94 26.91 26.95 +32" 26.100 26.99 26.90 KCONR 403 26.86 26.89 26.81 26.79 KCONR 403 26.93 26.91 KCONR+ 503 26.86 KCONR+ 503 26.90 26.102 PR 26.103 S3 Q1 438 26.81 26.86 26.85 26.84 Q1 438 26.91 26.95 26.90 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:44 AMENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E432 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.79 DISCONNECT AND REMOVE SCONCE AS ONE FOR ONE REPLACEMENT. 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.89 DISCONNECT AND REMOVE RECEPTACLE, JUNCTION BOX AND WIRE BACK TO SOURCE. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. 26.99 PROVIDE RECEPTACLE AT 18" AFF. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. 26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. 26.102 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND FAN. MAKE ALL FINAL CONNECTIONS. 26.103 INSTALL NEW SCONCE SUPPLIED BY OTHERS. MAKE FINAL CONNECTIONS. SCALE: 1/4" = 1'-0" DRAWING REF: E1041AGUESTROOM DEMOLITION - KE (439) SCALE: 1/4" = 1'-0"2A GUESTROOM NEW WORK - KE (439) SCALE: 1/4" = 1'-0" DRAWINGREF:E1043ADEMOLITION - KING CONDO (403) SCALE: 1/4" = 1'-0"4A NEW WORK - KING CONDO (403) SCALE: 1/4" = 1'-0" DRAWINGREF: E1046AGUESTROOM DEMOLITION - KING CONDO SPIRAL LOFT (503) SCALE: 1/4" = 1'-0"2C GUESTROOM NEW WORK - KING CONDO SPIRAL LOFT (503) SCALE: 1/4" = 1'-0"3C GUESTROOM DEMOLITION - Q (438) SCALE: 1/4" = 1'-0" DRAWING REF: E1044CGUESTROOM NEW WORK - Q (438) 9 7/21/17 CCD-05 07/31/2017 01/11/18 DW J DW3J J3J KCCON 401 26.86 26.81 TYPICAL 26.84 26.81 26.81 26.84 26.86 KCCON 401 26.94 5A E433 +39" MOUNT HORIZONTAL ON NEW WALL 26.91 26.104 26.92 26.90 26.93 TO REPLACEMENT LIGHTING ABOVE26.98 KCCON+ 501 26.79 26.78 26.86 26.81 26.81 KCCON+ 501 26.98 26.91 26.90 26.103 S3 4TH 131' 5TH FLOOR 05_FOURTH FLOOR 131' - 10" 06_TOP OF PLATE-2 140' - 2" 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:50 AMENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E433 2211 N FRONTAGE RD, VAIL, COLORADO 81657 KEYNOTES 26.78 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES AND WIRE BACK TO SOURCE. 26.79 DISCONNECT AND REMOVE SCONCE AS ONE FOR ONE REPLACEMENT. 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.94 PROVIDE ADA COMPLIANT LOW ENERGY DOOR OPENER AND PADDLE EQUAL TO DORMA ED900 FOR GUESTROOM. EXTEND AND CONNECT TO 120V (ALWAYS ON) HALL CIRCUIT. 26.98 PROVIDE NEW WIRE AND SWITCH EQUAL TO LEVITON 5613-2W AT 48" AFF. EXTEND AND RECONNECT AS 3-WAY. 26.103 INSTALL NEW SCONCE SUPPLIED BY OTHERS. MAKE FINAL CONNECTIONS. 26.104 PROVIDE BACKBOX AT 12" AFF AND EXTEND ORIGINAL DISH MACHINE CIRCUIT. RECONNECT MACHINE. SCALE: 1/4" = 1'-0" DRAWING REF: E1042AGUESTROOM DEMOLITION - KING CORNER (401) SCALE: 1/4" = 1'-0"4AGUESTROOM NEW WORK - KING CORNER (401) SCALE: 1/4" = 1'-0" DRAWING REF: E1043CGUESTROOM DEMOLITION - KING CORNER LOFT (501) SCALE: 1/4" = 1'-0"6C GUESTROOM NEW WORK - KING CORNER LOFT (501) SCALE: 1/4" = 1'-0" DRAWING REF: E4335AENLARGED KITCHEN AREA DETAIL 9 7/21/17 CCD-05 07/31/2017 01/11/18 J J HFSD KAR 203 26.81 26.81 26.84 26.8526.85 26.86 26.86 KAR 203 26.91 26.93 26.95 +32" 26.100 26.99 26.90 26.89 +72" 26.84 26.84 PR RELOCATED LIGHTING PR PR PR +32" PROVIDE NEW DATA OUTLET 26.92 26.95 26.93 26.100 26.95 26.95 PROVIDE NEW DATA OUTLET 26.90 26.80 26.83 26.87 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR INPART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/31/2017 9:14:55 AMENLARGED GUESTROOM PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E434 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E1021ADEMOLITION - KA DECOM (203) SCALE: 1/4" = 1'-0"2A NEW WORK - KA DECOM (203) KEYNOTES 26.99 PROVIDE RECEPTACLE AT 18" AFF. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. 26.100 PROVIDE RECEPTACLE AT HEIGHT SHOWN. EXTEND TO NEAREST RECEPTACLE CIRCUIT AND CONNECT. 26.80 DISCONNECT AND REMOVE FIRE ALARM DEVICES. REMOVE WIRE BACK TO REUSABLE LOCATION. 26.81 DISCONNECT AND REMOVE SWITCHING FOR RELOCATION / REPLACEMENT WITH NEW. 26.83 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW LIGHTING. 26.84 DISCONNECT AND REMOVE RECEPTACLE, BOX AND WIRE BACK TO REUSABLE LOCATION. CIRCUIT TO BE REUSED. 26.85 DISCONNECT AND REMOVE LIGHTING, ASSOCATED BOXES, WIRE AND SWITCHING BACK TO SOURCE. 26.86 DISCONNECT AND REMOVE SCONCE LIGHTING AND JUNCTION BOX. CIRCUIT TO BE EXTENDED AND REUSED FOR NEW BACK-LIT MIRROR. TYPICAL OF ALL GUESTROOMS. 26.87 DISCONNECT AND REMOVE LIGHTING. REMOVE WIRE BACK TO REUSABLE LOCATION. LIGHTING FIXTURE AND CIRCUIT TO BE REUSED. 26.89 DISCONNECT AND REMOVE RECEPTACLE, JUNCTION BOX AND WIRE BACK TO SOURCE. 26.90 PROVIDE BACKBOX AT 72" AFF FOR BACK-LIT ELECTRIC MIRROR. EXTEND CIRCUIT MADE AVAILABLE FROM VANITY SCONCE REMOVAL AND CONNECT. VERIFY FINAL J-BOX HEIGHT WITH APPROVED BACK-LIT MIRROR PRIOR TO ROUGH-IN. TYPICAL OF ALL GUESTROOMS. 26.91 PROVIDE SWITCH EQUAL TO LEVITON 5611-2W AT 48" AFF. EXTEND AND RECONNECT. 26.92 PROVIDE GFCI RECEPTACLE AT 44". EXTEND ORIGINAL CIRCUIT MADE AVAILABLE FROM DEMOLITION AND RECONNECT. 26.93 PROVIDE (2) SWITCHES EQUAL TO LEVITON 5611-2W AT 48" AFF. COMBINE LIGHTING AND BACK-LIT MIRROR ON ONE SWITCH AND CONNECT FAN ON THE SECOND SWITCH. MAKE ALL FINAL CONNECTIONS. TYPICAL FOR ALL GUESTROOMS. 26.95 PROVIDE RECEPTACLE AT 18" AFF. EXTEND ORIGINAL CIRCUIT AND RECONNECT. SCALE: 1/4" = 1'-0"4A2nd FL LAUNDRY DEMO - (206) SCALE: 1/4" = 1'-0"5AGUESTROOM NEW WORK - K (206) SCALE: 1/4" = 1'-0" DRAWING REF: E1023A2nd FL LAUNDRYLIGHTING DEMO - (206) LAUNDRY TO BE RETURNED TO GUESTROOMLAUNDRY TO BE RETURNED TO GUESTROOM 9 7/21/17 CCD-05 07/31/2017 01/11/18 PROJECT & ZONING INFO PROJECT NAME: ADDRESS: OWNER: OWNER ADDRESS: OWNER CONTACT PERSON: PHONE: APPLICABLE CODES BUILDING CODE: MECHANICAL CODE: PLUMBING CODE: ELECTRICAL CODE: FIRE CODE: STATE/CITY AMENDMENTS: ACCESSIBILITY CODE: ENERGY CODE: BUILDING OCCUPANCY USE GROUP: TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FIRE PROTECTION SYSTEMS AUTOMATIC SPRINKLER SYSTEM: STANDPIPE SYSTEM: FIRE ALARM & DETECTION SYSTEMS: FIRE DEPARTMENT CONNECTIONS: PORTABLE FIRE EXTINGUISHERS: FIRE RESISTANT RATING REQUIREMENTS FOR BUILDING ELEMENTS / FIREPROOFING SCHEDULE (REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC PENETRATION FIRESTOPPING DESIGN DETAILS) 1 2 1 0 0 1 1 IBC Section 7 FIRE WALLS & PARTY WALLS (IBC 705) 3 N/A FIRE SEPARATION ASSEMBLIES & PARTITIONS FIRE ENCLOSURE OF EXITS SHAFTS MIXED USE AND FIRE AREA SEPARATIONS EXIT ACCESS CORRIDORS TENANT SPACES SEPARATIONS DWELLING UNIT & GUESTROOM SEPARATIONS 2 2 N/A 2 N/A 1 EXISTING EXISTING N/A EXISTING N/A EXISTING FIRE RESISTANCE RATINGS OF STRUCTURAL ELEMENTS STRUCTURAL FRAME INCLUDING COLUMNS, GIRDERS & TRUSSES REQUIRED RATING (HRS) BEARING WALLS EXTERIOR INTERIOR NON-BEARING WALLS & PARTITIONS EXTERIOR (IBC TABLE 602) INTERIOR FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS IBC Table 601 DOUBLETREE HOTEL CONVERSION 2211 N. FRONTAGE ROAD VAIL, COLORADO 81657 THE WIDEWATERS GROUP 5788 WIDEWATER PARKWAY DEWITT, NEW YORK 13214 VALERIE THOPPE 954.675.1522 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2014 NATIONAL ELECTRICAL CODE ?? 2015 AMENDMENTS LOCATED IN ORDINANCE NO.14 SERIES 2015 2009 ICC/ANSI A117.1 2015 INTERNATIONAL ENERGY CONSERVATION CODE R1 RESIDENTIAL (HOTEL), NO CHANGE III-A EXISTING, NO CHANGE YES / EXISTING YES / EXISTING YES / EXISTING YES / EXISTING YES / EXISTING TEST # PROJECT INFO BUILDING SUMMARY INFORMATION BELOW IS REPLICATED FROM DRAWING SET PRODUCED BY LARRY TOPLISS AND DATED 10/08/1979 . USE GROUP: CONSTRUCTION TYPE: BUILDING ZONE: FIRE ZONE: CODES: SITE AREA: F.A.R.: B-1 RETAIL; COMMERCIAL R-1 RESIDENTIAL III - 1 HOUR C/L 3 1976 ED - UNIFORM BUILDING CODE 1973 ED - UNIFORM PLUMBING CODE 3,948 ACRES 171, 901 SF 0.50/1.0 = 85,995 SF MAX. HOTEL WING (3 FLOORS @ 15, 447 SF) 4TH FLOOR LOFT MAIN FLOOR (HOTEL OFFICES, LOBBY, ENTRY, COMMERCIAL, RETAIL) 2-STORY COMMERCIAL (2 x 4,732 SF) TOTAL BUILDING AREA 45,341 SF 7,544 SF 22,321 SF 9,464 SF 85,670 SF ACTUAL BUILDING AREA BY FLOOR: 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:19:18 PMBUILDING & CODE SUMMARY THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS G001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 CODE TABULATION - BUILDING OCCUPANCY (IBC 2015 TABLE 1004.1.1) NO. ROOM NAME FUNCTION OF SPACE AREA SF / OCC. # OF OCC. 13480 SF 56.83 4TH FLOOR 400 HOUSEKEEPING ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 275 SF 300 0.92 401 KCCON RESIDENTIAL 363 SF 200 1.81 402 KEX RESIDENTIAL 262 SF 200 1.31 403 KCONR RESIDENTIAL 337 SF 200 1.68 404 K1L RESIDENTIAL 273 SF 200 1.37 405 KKCON RESIDENTIAL 352 SF 200 1.76 406 QA RESIDENTIAL 2245 SF 200 11.22 407 K1L RESIDENTIAL 273 SF 200 1.37 408 KCONL RESIDENTIAL 301 SF 200 1.51 409 KKCON RESIDENTIAL 359 SF 200 1.80 410 Q1 RESIDENTIAL 180 SF 200 0.90 411 K1L RESIDENTIAL 273 SF 200 1.37 412 KCONL RESIDENTIAL 285 SF 200 1.42 413 KKCON RESIDENTIAL 357 SF 200 1.79 414 Q1 RESIDENTIAL 240 SF 200 1.20 415 K1L RESIDENTIAL 272 SF 200 1.36 416 KCONL RESIDENTIAL 306 SF 200 1.53 417 KKCON RESIDENTIAL 343 SF 200 1.72 418 Q1 RESIDENTIAL 239 SF 200 1.20 419 K1L RESIDENTIAL 272 SF 200 1.36 420 KCONL RESIDENTIAL 307 SF 200 1.54 421 KKCON RESIDENTIAL 357 SF 200 1.79 422 QA RESIDENTIAL 173 SF 200 0.86 423 K1L RESIDENTIAL 273 SF 200 1.37 424 KCONAL RESIDENTIAL 306 SF 200 1.53 425 KKCON RESIDENTIAL 357 SF 200 1.79 426 Q1 RESIDENTIAL 240 SF 200 1.20 427 K1L RESIDENTIAL 271 SF 200 1.35 428 KCONL RESIDENTIAL 306 SF 200 1.53 429 KKCON RESIDENTIAL 357 SF 200 1.79 430 Q1 RESIDENTIAL 239 SF 200 1.20 431 K1L RESIDENTIAL 271 SF 200 1.35 432 KCONL RESIDENTIAL 307 SF 200 1.53 433 KKCON RESIDENTIAL 357 SF 200 1.79 434 Q1 RESIDENTIAL 240 SF 200 1.20 435 K1L RESIDENTIAL 273 SF 200 1.37 436 DKL RESIDENTIAL 290 SF 200 1.45 437 DKR RESIDENTIAL 359 SF 200 1.79 438 Q1 RESIDENTIAL 259 SF 200 1.30 439 KEX RESIDENTIAL 308 SF 200 1.54 13661 SF 67.85 5TH FLOOR 501 KCCON+ RESIDENTIAL 483 SF 200 2.41 503 KCONR+ RESIDENTIAL 518 SF 200 2.59 505 KKCON+ RESIDENTIAL 434 SF 200 2.17 508 KCON+ RESIDENTIAL 311 SF 200 1.56 509 KKCON+ RESIDENTIAL 438 SF 200 2.19 512 KCONL+ RESIDENTIAL 283 SF 200 1.41 513 KKCON+ RESIDENTIAL 438 SF 200 2.19 516 KCON+ RESIDENTIAL 309 SF 200 1.55 517 KKCON+ RESIDENTIAL 436 SF 200 2.18 520 KCON+ RESIDENTIAL 310 SF 200 1.55 521 KKCON+ RESIDENTIAL 437 SF 200 2.18 524 KCON+ RESIDENTIAL 286 SF 200 1.43 525 KKCON+ RESIDENTIAL 437 SF 200 2.18 528 KCON+ RESIDENTIAL 310 SF 200 1.55 529 KKCON+ RESIDENTIAL 437 SF 200 2.18 532 KCON+ RESIDENTIAL 310 SF 200 1.55 533 KKCON+ RESIDENTIAL 437 SF 200 2.19 536 DKL+ RESIDENTIAL 104 SF 200 0.52 537 DKR+ RESIDENTIAL 640 SF 200 3.20 7357 SF 36.78 Grand total 65853 SF 913.40 NO. ROOM NAME FUNCTION OF SPACE AREA SF / OCC. # OF OCC. MAIN FLOOR 101 VESTIBULE (none) 84 SF 102 LOBBY LOUNGE WITH CONNECTIVITY ZONE ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 2921 SF 15 194.74 103 LOBBY BAR ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 1338 SF 15 89.19 104 BALLROOM/ MEETING ROOM ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 2001 SF 15 133.41 105 MADE MARKET ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 337 SF 15 22.48 106 GM OFFICE BUSINESS AREAS 127 SF 100 1.27 107 CHECK-IN BUSINESS AREAS 104 SF 100 1.04 108 WORK AREA BUSINESS AREAS 123 SF 100 1.23 109 RETAIL ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 353 SF 15 23.53 110 SKI BOOT REMOVAL AREA ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 186 SF 15 12.37 111 SKI & BOOT STORAGE ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 347 SF 300 1.16 112 EXIT PASSAGE (none) 245 SF 113 ELEVATOR EQUIP ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 46 SF 300 0.15 114 EXIT PASSAGE (none) 193 SF 115 ROOM (none) 37 SF 116 ELECTRICAL ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 325 SF 300 1.08 117 TELECOM ROOM ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 107 SF 300 0.36 118 LUGGAGE ROOM ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 130 SF 300 0.43 119 MASSAGE/ SPA WAITING ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 140 SF 15 9.31 119B CORRIDOR (none) 87 SF 120 ROOM BUSINESS AREAS 104 SF 100 1.04 121 ROOM BUSINESS AREAS 104 SF 100 1.04 122 ROOM BUSINESS AREAS 91 SF 100 0.91 123 ROOM BUSINESS AREAS 95 SF 100 0.95 124 ROOM BUSINESS AREAS 84 SF 100 0.84 125 CORRIDOR (none) 546 SF 126 BOARDROOM ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 280 SF 15 18.70 127 MEETING ROOM ASSEMBLY - UNCONCENTRATED (TABLES AND CHAIRS) 473 SF 15 31.51 128 RECEPTION BUSINESS AREAS 210 SF 100 2.10 129 OFFICE 4 BUSINESS AREAS 90 SF 100 0.90 130 OFFICE 3 BUSINESS AREAS 76 SF 100 0.76 131 OFFICE 2 (none) 74 SF 132 OFFICE 1 BUSINESS AREAS 76 SF 100 0.76 133 ENGINEER ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 244 SF 300 0.81 134 ENGINEER STORAGE ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 289 SF 300 0.96 135 STORAGE BUSINESS AREAS 191 SF 100 1.91 136 EMPLOYEE BREAK ROOM LOCKER ROOMS 360 SF 50 7.21 137 W EMPLOYEE LOCKER ROOM LOCKER ROOMS 273 SF 50 5.45 138 M EMPLOYEE LOCKER ROOM LOCKER ROOMS 274 SF 50 5.48 139 WOMEN'S BATHROOM (none) 166 SF 140 CORRIDOR (none) 460 SF 141 MEN'S BATHROOM (none) 159 SF 145 POOL EQUIP ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 291 SF 300 0.97 146 MECHANICAL ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 649 SF 300 2.16 147 GUEST LAUNDRY BUSINESS AREAS 110 SF 100 1.10 148 FITNESS CENTER EXERCISE ROOMS 1113 SF 50 22.27 149 MEN'S (none) 273 SF 150 WOMEN'S (none) 274 SF 151 KITCHEN KITCHENS - COMMERCIAL 607 SF 200 3.04 152 PREFUNCTION ASSEMBLY - STANDING SPACE 444 SF 5 88.86 153 MEETING STORAGE ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 221 SF 300 0.74 17932 SF 692.22 2ND FLOOR 200 LAUNDRY INDUSTRIAL AREAS 506 SF 100 5.06 200B JANITOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 42 SF 300 0.14 201 KS RESIDENTIAL 370 SF 200 1.85 202 K2 RESIDENTIAL 239 SF 200 1.20 203 KAR RESIDENTIAL 230 SF 200 1.15 204 KAL RESIDENTIAL 299 SF 200 1.49 205 QQ1L RESIDENTIAL 309 SF 200 1.54 206 K3 RESIDENTIAL 305 SF 200 1.52 207 QQ1R RESIDENTIAL 306 SF 200 1.53 208 K1L RESIDENTIAL 266 SF 200 1.33 209 QQ1L RESIDENTIAL 306 SF 200 1.53 210 K1R RESIDENTIAL 269 SF 200 1.34 211 QQ1R RESIDENTIAL 306 SF 200 1.53 212 K1L RESIDENTIAL 266 SF 200 1.33 213 QQ1L RESIDENTIAL 305 SF 200 1.52 214 K1R RESIDENTIAL 269 SF 200 1.34 215 QQ1R RESIDENTIAL 304 SF 200 1.52 216 K1L RESIDENTIAL 269 SF 200 1.34 217 QQ1L RESIDENTIAL 305 SF 200 1.53 218 K1R RESIDENTIAL 265 SF 200 1.33 219 QQ1R RESIDENTIAL 306 SF 200 1.53 220 K1L RESIDENTIAL 269 SF 200 1.34 221 QQ1L RESIDENTIAL 306 SF 200 1.53 222 K1R RESIDENTIAL 269 SF 200 1.34 223 QQ1R RESIDENTIAL 306 SF 200 1.53 224 K1L RESIDENTIAL 269 SF 200 1.34 225 QQ1L RESIDENTIAL 306 SF 200 1.53 226 K1R RESIDENTIAL 265 SF 200 1.33 227 QQ1R RESIDENTIAL 306 SF 200 1.53 228 K1L RESIDENTIAL 273 SF 200 1.36 229 QQ1L RESIDENTIAL 306 SF 200 1.53 230 K1R RESIDENTIAL 269 SF 200 1.34 231 QQ1R RESIDENTIAL 306 SF 200 1.53 232 K1L RESIDENTIAL 269 SF 200 1.34 233 QQ1R RESIDENTIAL 306 SF 200 1.53 234 K1R RESIDENTIAL 265 SF 200 1.33 235 QQARI RESIDENTIAL 304 SF 200 1.52 236 K1R RESIDENTIAL 266 SF 200 1.33 237 KARI RESIDENTIAL 292 SF 200 1.46 238 K1L RESIDENTIAL 261 SF 200 1.31 240 CORRIDOR (none) 1971 SF 13424 SF 59.72 3RD FLOOR 300 HOUSEKEEPING ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 275 SF 300 0.92 301 KS RESIDENTIAL 354 SF 200 1.77 302 QQ1L RESIDENTIAL 289 SF 200 1.44 303 QQ1R RESIDENTIAL 302 SF 200 1.51 304 QQ1L RESIDENTIAL 303 SF 200 1.51 305 QQ1R RESIDENTIAL 304 SF 200 1.52 306 QA RESIDENTIAL 257 SF 200 1.28 307 QQ1L RESIDENTIAL 302 SF 200 1.51 308 K1L RESIDENTIAL 265 SF 200 1.33 309 QQ1R RESIDENTIAL 302 SF 200 1.51 310 K1R RESIDENTIAL 265 SF 200 1.33 311 QQ1L RESIDENTIAL 302 SF 200 1.51 312 K1L RESIDENTIAL 266 SF 200 1.33 313 QQ1R RESIDENTIAL 302 SF 200 1.51 314 K1R RESIDENTIAL 265 SF 200 1.33 315 QQ1L RESIDENTIAL 301 SF 200 1.50 316 K1L RESIDENTIAL 266 SF 200 1.33 317 QQ1R RESIDENTIAL 300 SF 200 1.50 318 K1R RESIDENTIAL 265 SF 200 1.33 319 QQ1L RESIDENTIAL 301 SF 200 1.51 320 K1L RESIDENTIAL 266 SF 200 1.33 321 QQ1R RESIDENTIAL 302 SF 200 1.51 322 K1R RESIDENTIAL 265 SF 200 1.33 323 QQ1L RESIDENTIAL 302 SF 200 1.51 324 K1L RESIDENTIAL 266 SF 200 1.33 325 QQ1R RESIDENTIAL 302 SF 200 1.51 326 K1R RESIDENTIAL 265 SF 200 1.33 327 QQ1L RESIDENTIAL 302 SF 200 1.51 328 K1L RESIDENTIAL 266 SF 200 1.33 329 QQ1R RESIDENTIAL 302 SF 200 1.51 330 K1R RESIDENTIAL 265 SF 200 1.33 331 QQ1L RESIDENTIAL 302 SF 200 1.51 332 K1L RESIDENTIAL 266 SF 200 1.33 333 QQ1R RESIDENTIAL 302 SF 200 1.51 334 K1R RESIDENTIAL 265 SF 200 1.33 335 QQ1L RESIDENTIAL 302 SF 200 1.51 336 K1L RESIDENTIAL 266 SF 200 1.33 337 QQ1R RESIDENTIAL 302 SF 200 1.51 338 K1R RESIDENTIAL 261 SF 200 1.31 339 QQ1L RESIDENTIAL 300 SF 200 1.50 340 CORRIDOR (none) 2022 SF CODE TABULATION - MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (IBC 2015 TABLE 2902.1) NO. ROOM NAME AREA OCC. TYPE SF / OCC. # OF OCC. # OF MEN WC MEN LAV MEN # OF WOMEN WC WOMEN LAV WOMEN DRINKING FOUNTAINS SERVICE SINKS MAIN FLOOR 102 LOBBY LOUNGE WITH CONNECTIVITY ZONE 2921 SF A-3a 15 195 98 0.78 0.49 98 1.51 0.49 0.39 0.01 103 LOBBY BAR 1338 SF A-2b 15 90 45 0.60 0.23 45 0.60 0.23 0.18 0.01 104 BALLROOM/ MEETING ROOM 2001 SF A-3a 15 134 67 0.54 0.34 67 1.03 0.34 0.27 0.01 105 MADE MARKET 337 SF A-3a 15 23 12 0.10 0.06 12 0.18 0.06 0.05 0.01 106 GM OFFICE 127 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 107 CHECK-IN 104 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 108 WORK AREA 123 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 109 RETAIL 353 SF A-3a 15 24 12 0.10 0.06 12 0.18 0.06 0.05 0.01 110 SKI BOOT REMOVAL AREA 186 SF A-3a 15 13 7 0.06 0.04 7 0.11 0.04 0.03 0.01 111 SKI & BOOT STORAGE 347 SF B 300 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 116 ELECTRICAL 325 SF B 300 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 118 LUGGAGE ROOM 130 SF B 300 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 119 MASSAGE/ SPA WAITING 140 SF A-3a 15 10 5 0.04 0.03 5 0.08 0.03 0.02 0.01 120 ROOM 104 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 121 ROOM 104 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 122 ROOM 91 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 123 ROOM 95 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 124 ROOM 84 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 126 BOARDROOM 280 SF A-3a 15 19 10 0.08 0.05 10 0.15 0.05 0.04 0.01 127 MEETING ROOM 473 SF A-3a 15 32 16 0.13 0.08 16 0.25 0.08 0.06 0.01 128 RECEPTION 210 SF B 100 3 2 0.08 0.05 2 0.08 0.05 0.03 0.01 129 OFFICE 4 90 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 130 OFFICE 3 76 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 132 OFFICE 1 76 SF B 100 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 133 ENGINEER 244 SF B 300 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 134 ENGINEER STORAGE 289 SF B 300 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 135 STORAGE 191 SF B 100 2 1 0.04 0.03 1 0.04 0.03 0.02 0.01 136 EMPLOYEE BREAK ROOM 360 SF B 50 8 4 0.16 0.10 4 0.16 0.10 0.08 0.01 145 POOL EQUIP 291 SF B 300 1 1 0.04 0.03 1 0.04 0.03 0.01 0.01 146 MECHANICAL 649 SF B 300 3 2 0.08 0.05 2 0.08 0.05 0.03 0.01 147 GUEST LAUNDRY 110 SF F-1 & F-2 100 2 1 0.01 0.01 1 0.01 0.01 0.01 0.01 148 FITNESS CENTER 1113 SF A-3a 50 23 12 0.10 0.06 12 0.18 0.06 0.05 0.01 151 KITCHEN 607 SF B 200 4 2 0.08 0.05 2 0.08 0.05 0.04 0.01 152 PREFUNCTION 444 SF B 5 89 45 1.80 1.13 45 1.80 1.13 0.89 0.01 14414 SF 698 358 5.44 3.26 358 7.21 3.26 2.46 0.34 CODE DATA (IBC 2015) CODE DATA (EXISTING BUILDING) RENOVATED OCCUPANT LOAD PER IBC 2015 AREA NAME USE GROUP AREA (SQ. FT.) MIN SQ.FT./ OCC. MAX OCCUPANT LOAD LOBBY/LOUNGE A-3 3183 SF 15 213 BAR A-2 1492 SF 15 100 RESTAURANT A-3 2935 SF 15 196 POOL A-4 988 SF 50 19 STORAGE S 1680 SF 300 KITCHEN MEETING ROOMS BOH/EMPLOYEE B B A-3 3025 SF 573 SF 200 100 15 2316 SF FITNESS A-3 1206 SF 50 B 1086 SF 300 6 3 202 24 4 25 MECH/ELEC POOL DECK A-4 1737 SF 15 115 17496 SF 20221 SF TOTAL INTERIOR TOTAL 947 813 10/17/2016 01/11/18 DN DN UP DN DN REF FSB SB SB SB FCMF F FFV VF FVF V FFFFFRef. Under Counter DN 2 HR SMOKE COMPARTMENT BARRIER 2 HR FIRE BARRIER 1 HR SMOKE COMPARTMENT BARRIER 1 HR FIRE BARRIER NON-RATED SMOKE RESISTIVE PARTITION NON-RATED PARTITION 3 HR SMOKE COMPARTMENT BARRIER 3 HR FIRE BARRIER NOTE: ALL RATED CONSTRUCTION IS ALSO SMOKE RESISTIVE CONSTRUCTION SMOKE TIGHT CEILING 1-HR FIRE BARRIER CEILING WALL & CEILING BARRIERS 3'-0" DOOR 34.25"171CLEAR WIDTH 2314'-0" DOOR 46.25" CLEAR WIDTH PAIR 3'-0" DOORS 68.5"342CLEAR WIDTH PAIR 3'-8" DOORS 84.5"442CLEAR WIDTH 221PAIR 3'-10" DOORS 44.25" / LEAF CLEAR WIDTH 221PAIR 3'-10" DOORS 88.5"442CLEAR WIDTH EXIT OPENING CAPACITY EXIT OPENING CAPACITY ABOVE IS BASED ON .2" PER OCCUPANT AS STATED IN: IBC 2009 - SECTION 1003 EGRESS WIDTH VIRGINIA CONSTRUCTION CODE 2009 - SECTION 1003 EGRESS WIDTH STANDARDS - EXIT DISCHARGE CAPACITY BY DOOR F FIRE ALARM PULL STATION, +48" F FIRE ALARM HORN/STROBE DEVICE, +80" SYNCHRONIZED 15 CANDELA UNLESS OTHERWISE NOTED V FIRE ALARM STROBE ONLY, +80" SYNCHRONIZED 15 CANDELA UNLESS OTHERWISE NOTED SD FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR CEILING MOUNTED SD FIRE ALARM PHOTOELECTRIC DUCT SMOKE DETECTOR HOUSING WITH SENSOR AND REMOTE LED/ALARM TEST STATION FE FIRE EXTINGUISHER BRACKET MOUNTED FEC FIRE EXTINGUISHER CABINET (RECESSED/ SEMI RECESSED) FIRE PROTECTION & ALARM DEVICES CO2 CARBON MONOXIDE DETECTOR CEILING MOUNTED DIRECTIONAL ILLUMINATED EXIT SIGN EXIT DISCHARGE EXIT PASSAGEWAY HORIZONTAL EXIT EXIT ACCESS CORRIDOR EXIT STAIR (VERTICAL EXIT ENCLOSURE) COMMUNICATING STAIR ELEVATOR CONTROL ROOM AREA SUITE AREA SUITE EGRESS ELEV CSES HE EP EXIT/EGRESS SYMBOLS EXIT ACCESS TRAVEL DISTANCE (MAXIMUM ?'-?") COMMON PATH (MAXIMUM ?'-?") X'-X" X'-X" POINT OF EGRESS CHOICE TRAVEL DISTANCE LIMITATIONS MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 STAIR SKI & BOOT STORAGE 111 COVERED DROP OFF WORK AREA 108 DISHWASHING 106 BALLROOM/ MEETING ROOM 104 OFFICE 1 132 OFFICE 3 130 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 W EMPLOYEE LOCKER ROOM 137 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 MASSAGE/ SPA WAITING 119 LUGGAGE ROOM 118 TELECOM ROOM 117 ROOM 122 ROOM 121 ROOM 120 ROOM 123 ROOM 124 SKI BOOT REMOVAL AREA 110 VESTIBULE 101 CHECK-IN 107 MEN'S 149 WOMEN'S 150 GUEST LAUNDRY 147 KITCHEN 151 MADE MARKET 105 PREFUNCTION 152 LOBBY BAR 103 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 SPA POOL MEETING STORAGE 153 EXIT PATH 'A1' EXIT PATH 'E1' EXIT PATH 'G1' EXIT PATH 'H1' EXIT PATH 'B1' EXIT PATH 'C1' EXIT PATH 'J1' EXIT PATH 'K1' EXIT PATH 'D1' EXIT PATH 'L1' EXIT PATH 'M1' EXIT PATH 'N1' EXIT PATH 'Q1' EXIT PATH 'P1' EXIT PATH 'R1' ASSEMBLY - A3 472 SF NET/15 = 32 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 304 SF NET/15 = 21 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED BUSINESS - B 537 SF GROSS/100 = 6 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 140 SF NET/15 = 10 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED BUSINESS - B 449 SF GROSS/100 = 5 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 416 SF NET/15 = 28 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED BUSINESS - B 186 SF GROSS/100 = 2 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 119 SF NET/15 = 8 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 1119 SF NET/15 = 75 OCCUPANTS 1 EXIT REQUIRED 2 EXITS PROVIDED ASSEMBLY - A3 294 SF NET/15 = 20 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 192 SF NET/15 = 13 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 3021 SF NET/15 = 202 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED ASSEMBLY - A3 1322 SF NET/15 = 89 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED BUSINESS - B 252 SF GROSS/100 = 3 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ASSEMBLY - A3 1834 SF NET/15 = 123 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED ASSEMBLY - A3 481 SF NET/15 = 32 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED ES FF RECEPTION 128 FF F FFFFEC SD FSD F SD F SD F SD F SD F SD F SD BUSINESS - B 396 SF NET/300 = 2 OCCUPANTS 1 EXIT REQUIRED 1 EXIT PROVIDED BUSINESS - B 664 SF GROSS/200 = 4 OCCUPANTS 1 EXIT REQUIRED 2 EXITS PROVIDED BUSINESS - B 91 SF NET/100 = 1 OCCUPANTS 1 EXITS REQUIRED 2 EXITS PROVIDED EXIT PATH 'S1' ADA COMPLIANT RAMP @ 1:12 MAX SLOPE WITH 30'-0" MAX RUN 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®1/5/2018 3:53:02 PMLIFE SAFETY LEGEND & LIFE SAFETY PLAN - 1ST FLOOR THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS G002 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LEGEND - LIFE SAFETY 1. FIRE EXTINGUISHER CABINETS SHALL BE LOCATED SO THAT THE MAXIMUM TRAVEL DISTANCE SHALL NOT EXCEED 75'-0". 2. MINIMUM EGRESS WIDTH PER OCCUPANT AT STAIRS = 0.3" PER OCCUPANT. MINIMUM EGRESS WIDTH PER OCCUPANT AT OTHER EGRESS COMPONENTS = 0.2" PER OCCUPANT. (TABLE 1005.1) 3. A FIRE RATED ASSEMBLY AND SMOKE BARRIER ASSEMBLY SHALL BE STENCILED WITH THE RELEVANT DESIGNATION AS FOLLOWS: - 3-INCH TALL LETTERS IN RED INK OR PAINT. - APPLIED AT ALL CONCEALED LOCATIONS (EG., ABOVE CEILING AND INSIDE ELEVATOR SHAFTS) @ 8'-0" OC MAX. 4. ALL GUESTROOM DOORS ARE 20 MIN. RATED 5. ALL STAIR EXIT DOORS ARE 90 MIN. RATED NOTES - LIFE SAFETY (GENERAL) SCALE: 3/32" = 1'-0"DRAWING REF:A0306ALIFE SAFETY PLAN - FIRST FLOOR TYPE PATH OF EGRESS EXIT PATH 'K1' COMMON PATH OF EGRESS TRAVEL 14'-6" EXIT ACCESS TRAVEL DISTANCE 2'-10" 17'-4" EXIT PATH 'L1' COMMON PATH OF EGRESS TRAVEL 31'-11" EXIT ACCESS TRAVEL DISTANCE 69'-9" 101'-8" EXIT PATH 'M1' COMMON PATH OF EGRESS TRAVEL 31'-11" EXIT ACCESS TRAVEL DISTANCE 63'-4" 95'-3" EXIT PATH 'N1' COMMON PATH OF EGRESS TRAVEL 19'-0" EXIT ACCESS TRAVEL DISTANCE 67'-11" 86'-11" EXIT PATH 'P1' COMMON PATH OF EGRESS TRAVEL 27'-11" EXIT ACCESS TRAVEL DISTANCE 67'-11" 95'-10" EXIT PATH 'Q1' COMMON PATH OF EGRESS TRAVEL 37'-11" EXIT ACCESS TRAVEL DISTANCE 27'-5" 65'-4" EXIT PATH 'R1' COMMON PATH OF EGRESS TRAVEL 11'-6" EXIT ACCESS TRAVEL DISTANCE 64'-4" 75'-10" EXIT PATH 'S1' COMMON PATH OF EGRESS TRAVEL 79'-5" 79'-5" TYPE PATH OF EGRESS 1ST FLOOR COMMON PATH OF EGRESS TRAVEL 1'-8" 1'-8" EXIT PATH 'A1' COMMON PATH OF EGRESS TRAVEL 41'-10" EXIT ACCESS TRAVEL DISTANCE 48'-10" 90'-7" EXIT PATH 'B1' COMMON PATH OF EGRESS TRAVEL 35'-5" EXIT ACCESS TRAVEL DISTANCE 66'-2" 101'-7" EXIT PATH 'C1' COMMON PATH OF EGRESS TRAVEL 37'-0" EXIT ACCESS TRAVEL DISTANCE 39'-2" 76'-2" EXIT PATH 'D1' COMMON PATH OF EGRESS TRAVEL 44'-5" EXIT ACCESS TRAVEL DISTANCE 49'-9" 94'-3" EXIT PATH 'E1' COMMON PATH OF EGRESS TRAVEL 21'-4" EXIT ACCESS TRAVEL DISTANCE 43'-4" 64'-9" EXIT PATH 'G1' COMMON PATH OF EGRESS TRAVEL 29'-10" EXIT ACCESS TRAVEL DISTANCE 13'-3" 43'-0" EXIT PATH 'H1' COMMON PATH OF EGRESS TRAVEL 29'-9" EXIT ACCESS TRAVEL DISTANCE 13'-3" 43'-0" EXIT PATH 'J1' COMMON PATH OF EGRESS TRAVEL 14'-6" EXIT ACCESS TRAVEL DISTANCE 24'-3" 38'-9" 9 7/21/2017 CCD-005 10 9/15/2017 CCD-006 13 12/01/2017 CCD-09 14 12/22/2017 TOV COMMENTS 01/05/2018 01/11/18 DN UP K1L 208 QQ1L 205 KAL 204 KS 201 K1L 228 K1L 238 K1R 236 K1R 234 K1L 232 K1R 230 K1R 226 K1L 224 K1R 222 K1L 220 K1R 218 K1L 216 K1R 214 K1L 212 K1R 210 KARI 237 QQARI 235 QQ1R 233 QQ1R 231 QQ1L 229 QQ1R 227 QQ1L 225 QQ1R 223 QQ1L 221 QQ1R 219 QQ1L 217 QQ1R 215 QQ1L 213 QQ1R 211 QQ1L 209 QQ1R 207 K3 206 KAR 203 K2 202 LAUNDRY 200 CORRIDOR 240 FFF F F F SD SD SD SD SD SD SD SD SD SD F F FEC FEC FE FE CO2 CO2 LOW LOW EXIT PATH 'B2' EXIT PATH 'A2' RESIDENTIAL - R1 10962 SF GROSS/200 = 55 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED JANITOR 200B ES ES KS 301 K1R 338 K1L 336 K1R 334 K1L 332 K1R 330 K1L 328 K1R 326 K1L 324 K1R 322 K1L 320 K1R 318 K1L 316 K1R 314 K1L 312 K1R 310 K1L 308 QA 306 QQ1L 339 QQ1R 337 QQ1L 335 QQ1R 333 QQ1L 331 QQ1R 329 QQ1L 327 QQ1R 325 QQ1L 323 QQ1R 321 QQ1L 319 QQ1R 317 QQ1L 315 QQ1R 313 QQ1L 311 QQ1R 309 QQ1L 307 QQ1R 305 QQ1L 304 QQ1R 303 QQ1L 302 HOUSEKEEPING 300 CORRIDOR 340SD SD SD SD SD SD SD SD SD SD FFFFF F F FEC FEC FE LOW LOW EXIT PATH 'B3' EXIT PATH 'A3' RESIDENTIAL - R1 11195 SF GROSS/200 = 56 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED ES ES 4E A122 6E A122 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:20:41 PMLIFE SAFETY PLANS - 2ND & 3RD FLOORS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS G003 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0"6ALIFE SAFETY PLAN - 2ND FLOOR SCALE: 1/8" = 1'-0"6D LIFE SAFETY PLAN - 3RD FLOOR TYPE PATH OF EGRESS 2ND FLOOR EXIT PATH 'A2' COMMON PATH OF EGRESS TRAVEL 34'-1" EXIT ACCESS TRAVEL DISTANCE 115'-7" 149'-8" EXIT PATH 'B2' COMMON PATH OF EGRESS TRAVEL 37'-1" EXIT ACCESS TRAVEL DISTANCE 114'-2" 151'-3" 3RD FLOOR EXIT PATH 'A3' COMMON PATH OF EGRESS TRAVEL 34'-1" EXIT ACCESS TRAVEL DISTANCE 115'-7" 149'-8" EXIT PATH 'B3' COMMON PATH OF EGRESS TRAVEL 37'-1" EXIT ACCESS TRAVEL DISTANCE 114'-2" 151'-3" 10/17/2016 01/11/18 DN UP UP UP UPUPUPUPUPUPUPUPUP REF DN DN DN HOUSEKEEPING 400 KCCON 401 QA 406 KCONL 408 Q1 410 KCONL 412 Q1 414 KCONL 416 Q1 418 KCONL 420 QA 422 KCONAL 424 Q1 426 KCONL 428 Q1 430 KCONL 432 Q1 434 DKL 436 Q1 438 KEX 439 DKR 437 K1L 435 KKCON 433 K1L 431 KKCON 429 K1L 427 KKCON 425 K1L 423 KKCON 421 K1L 419 KKCON 417 K1L 415 KKCON 413 K1L 411 KKCON 409 K1L 407 KKCON 405 K1L 404 KCONR 403 KEX 402 CORRIDOR 440SD SD SD SD SD SD SD F F FEC FEC FE LOW LOW SD F CLG F CLG F CLG SD SD F CLG SD F CLG EXIT PATH 'B4' EXIT PATH 'A4' RESIDENTIAL - R1 11488 SF GROSS/200 = 58 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED ES ES 4E A122 DKR+ 537 DKL+ 536 KCON+ 532 KKCON+ 533 KKCON+ 529 KKCON+ 525 KKCON+ 521 KKCON+ 517 KKCON+ 513 KKCON+ 509 KKCON+ 505 KCONR+ 503 KCON+ 528 KCON+ 524 KCON+ 520 KCON+ 516 KCONL+ 512 KCON+ 508 KCCON+ 501 OPEN TO HOUSEKEEPING ELEVATOR SHAFT RESIDENTIAL - R1 7717 SF GROSS/200 = 39 OCCUPANTS 2 EXITS REQUIRED 2 EXITS PROVIDED OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW STAIR SHAFT STAIR SHAFT 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®10/12/2016 6:21:15 PMLIFE SAFETY PLANS - 4TH FLOOR & LOFT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/2016 - CONSTRUCTION DOCUMENTS G004 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: A5016ALIFE SAFETY PLAN - 4TH FLOOR SCALE: 1/8" = 1'-0" DRAWING REF: A5016DLIFE SAFETY PLAN - 4TH FLOOR UPPER LEVEL/ LOFT TYPE PATH OF EGRESS 4TH FLOOR EXIT PATH 'A4' COMMON PATH OF EGRESS TRAVEL 32'-7" EXIT ACCESS TRAVEL DISTANCE 115'-7" 148'-2" EXIT PATH 'B4' COMMON PATH OF EGRESS TRAVEL 33'-4" EXIT ACCESS TRAVEL DISTANCE 114'-2" 147'-6" 10/17/2016 01/11/18 REF Ref. Under Counter GDD DR DR DD D DD D DCHD D D D CH DD D CH D C HD TRASHD D D $TRASHTRASHTRASHD DTRASH$ K101 2A K101 4A K201 2A K201 4A K301 2A K301 4A K401 2A K401 4A K102K302K202 5A 13 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:07 PMOVERALL FOODSERVICE EQUIPMENT LAYOUT THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K100 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE:1/8" = 1'-0"DRAWINGREF: A1116AOVERALL FOOD SERVICE - PLAN 109/15/2017CCD-006 1312/01/2017CCD-09 12/28/2017 01/11/18 EP.O. BOX 400, RICHMOND, VA 23218-0400 OWNER ® TOWN OF VAIL USE THE WIDEWATERS GROUP P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 3938 37 18 15 4 6 8 21 22 25 24 28 27 22 7 33 30 42 34 1 2 3 9 11 17 36 13 12 15 14 5 22 29 35 35 35 32 31 33 26 19 20 10 23 44 45 40 43 41 29.1 29.2 40 46 6 16 48 47 48 49 50 52 51 53 56 56 54 55 53 53 57 29.3 29.4 18A 18B GAIRFLOW DD D R D R D D D CWODD D D CH D D D D CH DD D CH D C HD TRASHD D D $TRASHTRASHTRASHD DTRASH$ FINISH NO. MATERIAL MANUFACTURER STYLE NO./NAME COLOR SIZE ACT - 01 FRP - 01 CT - 01 ACOUSTIC CEILING TILE ARMSTRONG KITCHEN ZONE WHITE 24" X 48" FIBER REINFORCED PANELS MARLITE STANDARD FRP WHITE 4' X 8' X 3/32" SEAMLESS EPOXY W/ COVE BASE BY GC SEAMLESS EPOXY GREY MATCH EXISTING 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:15 PMENLARGED KITCHEN FOOD SERVICE EQUIPMENT PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K102 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 SCALE:1/4" = 1'-0"DRAWING REF:K1005AENLARGED KITCHEN FOOD SERVICE EQUIPMENT PLAN KITCHEN FINISH SCHEDULE 13 12/28/2017 01/11/18 EP.O. BOX 400, RICHMOND, VA 23218-0400 OWNER ® TOWN OF VAIL USE THE WIDEWATERS GROUP P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 D R GGDD D DD D 1'-6" P 1 P 2 P 3 2'-6" P 8 P 9 P 10 P 32 P 12 P 7 4" 6" 12"P 6 P 5 P 4 2'-6" P 11 18" 18" 8" 16" 18" P 16 P 12 3'-0" P 21 P 20 8" P 18 P 17 P 36 4" P 13 P 15 P 14 16'-0" P 23 P 22 7'-10"8" 12" 4" 5'-2" 3'-2"4" 8"3'-10" 1'-4" 2'-6" 2'-0" 1'-0" 4" 3'-10" 4" P 13 P 14 P 15 P 13 P 14 P 15 1'-4" P 31 P 30 P 37 P 25 P 26 P 24 P 28 P 35 P 34 P 33 P 29 P 31 P 30 P 27 P 29 1'-4" 14" P 39 5'-6" P 38 P 40 12" 3'-4" P-2 P-3 MOP SINK(FAUCET) MOP SINK(FAUCET) 8 8 1/2" 1/2" 36" 36" PLUMBING ROUGH-IN KEY (WATER AND GAS) MAIN GAS LINE - EXISTING P-16 P-18 P-17 P-15 P-14 P-13 P-12 P-11 P-10 P-8 P-9 P-1 ITEM KEY DESCRIPTION C.W. W. I.W. H.W. MBTU GAS DRAINHT. COUNTER GRIDDLE 3 22 HANDSINK UNIT 1 1/2" 16" P-4 FRYER 9 110 12"3/4" P-21 SINK(FAUCET) SINK(FAUCET) 22 22 1/2" 20" 1/2" 20" COUNTER CHARBROILER 1 P-22 SALAMANDER BROILER 12 28 1/2" 72" P-23 P-24 P-29 P-31 P-7 P-6 P-5 P-20 P-25 P-27 P-30 P-32 P-33 P-26 P-34 P-35 P-36 56.6 12"3/4" 80 3/4" 12" MOP SINK 8 2" (PC TO CAP EXISTING FS BELOW SLAB)EXISTING FLOOR SINK 4-BURNER RANGE 13 164 3/4" 12" EXISTING FLOOR SINK DOUBLE CONVECTION OVEN 17 106 1" 12" 24 BEVERAGE STAND 24 BEVERAGE STAND (PC TO BTC TO EXISTING FLOOR SINK) (PC TO BTC TO EXISTING FLOOR SINK) 24 24 SINK(FAUCET) SINK(FAUCET) 1/2" 1/2" 12" 12" 27 ICE MACHINE 28 ICE BIN 3/4" 3/4" 27 ICE MACHINE 1/2" (PC TO BTC FROM ITEM#27.1) (PC TO BTC TO ITEM#27)1/2" 60" 27.1 WATER FILTER SYSTEM EVAPORATOR COIL (COOLER) EVAPORATOR COIL (FREEZER) 29.1 29.2 3/4" 3/4" (PC TO BTC TO MOP SINK ITEM #8) (PC TO BTC TO MOP SINK ITEM #8) SOILED DISHTABLE 30 DISHMACHINE 31 DISHMACHINE (BOOSTER HEATER) 31 1 1/2" 2" 3/4" FS FS FS (PC TO EXTEND FLOOR SINK TO GREASE TRAP) (PC TO EXTEND FLOOR SINK TO GREASE TRAP) (PC TO EXTEND FLOOR SINK TO GREASE TRAP) PRE-RINSE FAUCET 30 30 PRE-RINSE FAUCET 12" 12" DISHMACHINE 31 DISHMACHINE (BOOSTER HEATER) 31 (PC TO BTC FROM BOOSTER HEATER) (PC TO BTC TO DISHMACHINE) 3/4" @ 180° 3/4" @ 110° 12" P-28 3-COMPARTMENT SINK 33 (3)1 1/2" FS (PC TO EXTEND FLOOR SINK TO GREASE TRAP) 33 33 3-COMPARTMENT SINK (FAUCET) 3-COMPARTMENT SINK (FAUCET) 1/2" 1/2" 12" 12" PIZZA OVEN 36 125 3/4" 12" 45 DROP-IN HANDSINK UNIT 1 1/2" 16" SINK(FAUCET) SINK(FAUCET) 45 45 1/2" 20" 1/2" 20" WATER FOR OWNER EQUIPMENT 1/2" 48" P-37 AREA FLOOR DRAIN (VERIFY GAS REQUIREMENTS) P-38 P-39 ESPRESSO MACHINE (WATER FILTER) 54 ESPRESSO MACHINE 54 (PC TO BTC FROM WATER FILTER SYSTEM) 1/2" 1" P-40 ESPRESSO MACHINE 54 12" 3/8" 1" 1 1/2" P-19 UNUSED NUMBER (PC TO BTC TO EXISTING FLOOR SINK) (PC TO BTC TO EXISTING FLOOR SINK) FS KEY TO SYMBOLS AND ABBREVIATIONS POUNDS PER SQUARE INCH CUBIC FEET PER MINUTE BRANCH TO CONNECTION BRITISH THERMAL UNITS PSI AFF BTU CFM BTC ABOVE FINISH FLOOR W IW FD SR FFD FS S G HW CW WASTE STEAM RETURN INDIRECT WASTE FLOOR DRAIN FUNNEL FLOOR DRAIN FLOOR SINK STEAM COLD WATER HOT WATER GAS SHOP WIRING FIELD WIRING CORD AND PLUG DISCONNECT SWITCH ELECTRIC CONNECTIONEC SWITCH HORSEPOWER KILOWATTS DUPLEX RECEPTACLE SINGLE RECEPTACLE ELECTRIC LIGHT PHASE VOLTS CYCLES JUNCTION BOX S 0 HP KW JB V CY PH SR DR INCLUDING DRAIN LINES FOR HOT FOOD WELLS. PLUMBER TO PROVIDE ALL SHUT OFF VALES ON ALL WATER CONNECTIONS NEAREST FLOOR DRAINS AS REQUIRED. COMPRESSORS, ICE MACHINES, STEAM TABLES, COLD PANS, ETC. TO PLUMBER TO EXTEND ALL INDIRECT WASTE LINES FROM EVAPORATOR COILS, AND FITTINGS BETWEEN OUTLETS ON FIXTURE AND ROUGHED OUT CONNECTIONS. WALL OR COLUMNS. ALLOWANCES MUST BE MADE FOR ALL VALVES, TRAPS WALL OR PARTITION AT REAR. ALL DIMENSIONS ARE FROM FINISHED FLOOR, ALL DIMENSIONS FOR CONNECTIONS TO THE FIXTURES SHOULD COME OUT OF THE SIZE AND FURNISH GREASE TRAP AS SPECIFIED BY MECHANICAL CONTRACTOR. PLUMBER TO PROVIDE GREASE RECEPTOR AS CODE REQUIRES. PLUMBER TO COOKING EQUIPMENT AS SUPPLIED BY KITCHEN CONTRACTOR (K.E.C.) PLUMBER TO INSTALL AUTOMATIC SHUT-OFF VALVES IN GAS SUPPLY LINES OF ALL PREVAILING LOCAL PLUMBING CODES TO BE ACCOMMODATED. PREVENTION SYSTEM DEVICES, ETC. PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS, DRAIN LINES AND BACKFLOW EQUIPMENT. PLUMBER TO FURNISH ALL TRIM, ACCESSORIES, VALVES, PLUMBER TO DO ALL ROUGHING AND MAKE ALL FINAL CONNECTIONS TO DRAINS OTHER THAN SHOWN FOR CODE REASONS, ETC., SEE ARCHITECTS PLANS. ONLY. FOR OTHER REQUIREMENTS, SUCH AS TOILET FACILITIES, AREA FLOOR THIS PLAN SHOWS PLUMBING REQUIREMENTS FOR FOOD SERVICE EQUIPMENT FOR FIRE SYSTEM. PLUMBING NOTES: 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/22/2017 1:34:38 PMENLARGED KITCHEN PLUMBING ROUGH-IN PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K202 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 14 12/22/2017 TOV COMMENTS SCALE:1/4" = 1'-0"DRAWING REF: K1005AENLARGED KITCHEN PLUMBING ROUGH-IN PLAN REMOVED FIXTURES FROM EXISTING KITCHEN: -3-COMPARTMENT SINK -DISHTABLE -DISHMACHINE FIXTURES ADDED TO NEW KITCHEN - (2) 3-COMPARTMENT SINKS WITH BOWL DIMEINSIONS (16βX20βX18β) -DISHTABLE (20βX20βX5β BOWL) -DISHMACHINE TOTAL EQUIVALENT NEW DRAINAGE LOAD -3-COMPARTMENT SINK DRAINING IN 1 MINUTE: 25 GPM NEW 1500 GALLON GREASE INTERCEPTOR TO BE ADDED TO EXTISTING 1500 GALLON CAPACITY GREASE INTERCEPTOR TO MAKE TOTAL GREASE HOLDING CAPACITY 3000 GALLONS 12/22/2017 01/11/18 13 ITEM DESCRIPTION MAKE MODEL QTY. VOLTSHPKWAMPS.PHASECORD/PLUGDIRECTREMARKS HOT (IN)COLD (IN)DIRECTWASTE (IN)FLOOR SINKGAS (IN)MBTUHREMARKS 3/4 INDIRECT WASTE STOCK POT KETTLE 19 EVAPORATOR COIL COOLER 1 3/4 INDIRECT WASTE 1/2 1/2 1 1/2 17 21 18 INDIRECT WASTE WALK-IN COOLER/FREEZER 1 MOP SINK WATER FILTER 1 20 120 5.7 1 X1/5 2 12 11 4 3 5 6 7 8 9 10 14 2 SHELVING UNIT 1 22 23 24 25 26 27 28 29 30 31 32 33 34 ICE MACHINE 1 HANDSINK W/SOAP TOWEL DISP.3 3-COMPARTMENT SINK 1 2 15 REFRIGERATED EQUIPMENT STAND 16 1 (2)120 1 X10.0 208 1 X12.4 120 1 X4.4 1 120 1 15.2 X FC-3-1620-18RL 9-OP-40 EC-1848 W/ECPC-74 PER OWNER SEE SHOP DWGS CONTINENTAL DL48G 1/2 1/2 7-PS-87 1 1/2 SCOTSMAN C0530MA-1 3M ICE160-S PF-QUAD-7FC-S 1/2 3/4 FILTERED WATER, VERIFY REQUIREMENTS, INDIRECT WASTE 1/2 SEE SHOP DWGS VOLLRATH 7217255 120 1 X12.0 1.45 COUNTER CHARBROILER STAR MANUF. 6024CBF 1 3/4 80 PROVIDE QUICK DISCONNECT COUNTER GRIDDLE STAR MANUF. 624TF 1 3/4 56.6 PROVIDE QUICK DISCONNECT 120 6.6 1 X1/4 REFRIGERATED PREP TABLE 1 CONTINENTAL DL60-24M HEAT LAMPS 2 120 1 1.1 HATCO GRAH-48 X EC TO INTERWIRE (2) UNITS DOUBLE OVERSHELF ADVANCE TABCO 2(1) ODS-15-84 (1) ODS-15-72 120 15.0 1 X1.8 HEATED PROOFER CABINET 1ADMIRAL CRAFT PW-120 ADVANCE TABCO DIRECT WASTEINCLUDE SERVICE FAUCET 1/2 1/2 FRYERS GARLAND M35SS 2 3/4 110 PROVIDE QUICK DISCONNECT WORKTABLE ADVANCE TABCO TFMSU-150 1 SALAMANDER BROILER GARLAND MSTSR16 1 1/2 28 2 4-BURNER RANGE GARLAND G24-4L 1 3/4 164 PROVIDE QUICK DISCONNECT DISHCABINET ADVANCE TABCO DC-1513 MOD 1 120 13.7 1 X1/2 REFRIGERATED PREP TABLE 2 CONTINENTAL CPA68 WORKTABLE ADVANCE TABCO AG-362 1 DOUBLE CONVECTION OVEN GARLAND SCO-GS-20S 1 1 106 PROVIDE QUICK DISCONNECT(2)120 9.8 1 X3/4 EXHAUST HOOD CAPTIVE AIRE FABRICATE 1 120 1 X 10.0 VERIFY W/SHOP DRAWINGS MOBILE WORKTABLE ADVANCE TABCO SAG-244 1 120 13.0 1 X1/2 REFRIGERATED PIZZA PREP 1 CONTINENTAL CPA-60 PAN RACKS PR18-3W 2ADVANCE TABCO ADVANCE TABCO DIRECT WASTE BEVERAGE STAND ADVANCE TABCO 1 BEV-30-60L 1 120 6.1 1 X1/3 WORKTOP FREEZER 1 CONTINENTAL CFA43 SECURITY SHELVING UNIT ADVANCE TABCO SEC56EC 1 W/(2) 5MP & (2) 5MPB 27.1 ICE BIN 1SCOTSMAN B530P/S 3/4 INDIRECT WASTE 35 36 29.1 29.2 29.3 29.4 PER OWNER EVAPORATOR COIL FREEZER 1 SEE SHOP DWGSPER OWNER CONDENSING UNIT COOLER SEE SHOP DWGSPER OWNER CONDENSING UNIT FREEZER SEE SHOP DWGSPER OWNER 1 1 SOILED DISHTABLE 1 DTS-S70-60L-MOD 1/21/2 1 1/2INCLUDE PRE-RINSE FAUCET CLEAN DISHTABLE 1DTC-S70-36R DISHMACHINE INSINGER 1CA-3C 208 3 31.3 X 5.0 208 3 X 24.0 (BOOSTER HEATER) (MACHINE) 1/2 1/2 (3)1 1/2INCLUDE FAUCET ADVANCE TABCO ADVANCE TABCO ADVANCE TABCO ADVANCE TABCO WALK-IN SHELVING UNITS 7SEE DWGS FOR SIZESADVANCE TABCO CONDENSATE HOOD ADVANCE TABCO CH-3636 1 37 38 39 3/4 125 PROVIDE QUICK DISCONNECTHEARTH PIZZA OVEN FORNO BRAVO FPRO110-FA-ZZ-A-NG 1 120 1 X2.0 PASS THRU SHELF DIGITAL MENU BOARD ORDER STATION COUNTER ADVANCE TABCO PA-12-24 MOD ADVANCE TABCO 1 1 1TSFG-243 BY OWNER 120 1 X10.0 LOCATED ON ROOF BY KEC LOCATED ON ROOF BY KEC 208 208 3 3 1.5 2 40 41 42 43 WALL POTRACK ADVANCE TABCO PS-12-84 2 FIRE SYSTEM FOR ITEM #18 CAPTIVE AIRE FABRICATE 1 120 1 X 10.0 VERIFY W/SHOP DRAWINGS 44 45 SHELVING UNIT 1EC-1830 W/ECPC-74ADVANCE TABCO TRASH RECEPTACLE/DOLLY LOTRUBBERMAID FG262000GRAY FG264043BLA ADVANCE TABCO ADVANCE TABCO GLASS RACK DOUBLE OVERSHELF DROP-IN HANDSINK W/SIDE SPLASH DTA-79 HIGH 1 1 DI-1-10SP INCLUDE K-55 FAUCET 1/2 1/2 1 1/2 DIRECT WASTE 2 3/4 1/2 @180 1/2 @ 110 46 47 48 49 50 51 52 53 54 55 56 BAG N' BOX SYSTEM BY SODA SUPPLIER 1 120 1 X 6.0 1/4 1/2 ATM MACHINE BY OWNER 1 120 1 X20.0 REFRIG. OPEN MERCHANDISERS FEDERAL 2 RSSM-478SC 120 1 X13.0 3/4 REFRIGERATED WINE DISPLAY TRUE GDM-23W-HC-LD FREEZER MERCHANDISER TRUE GDM-23F-LD 1 120 1 120 1 X5.4 1/3 1 X9.0 3/4 CABINETRY - BY OWNER MILLWORK CHAMPION CABINETRY ON SITE POP-UP TOASTER CT4 STAR/HOLMAN LOT 1 120 1 X16.6 2.0 CABINETRY - BY OWNER MILLWORK STARBUCKS 1 57 58 120 1 X15.0 KIOSK LIGHTING ESPRESSO MACHINE MILLWORK STARBUCKS REFRIGERATOR MILLWORK STARBUCKS 1 1 208 2.8 1 X 120 1 X15.0 3/8 1 INDIRECT WASTE SLAT WALL - BY OWNER MILLWORK CHAMPION LOT WATER COUNTER - BY OWNER MILLWORK CHAMPION LOT POS COUNTER - BY OWNER MILLWORK CHAMPION LOT E Q U I P M E N T S C H E D U L E 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:25 PMKITCHEN EQUIPMENT SCHEDULE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K250 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 NOT TO SCALE6AFOOD SERVICE SCHEDULE 13 12/28/2017 01/11/18 EP.O. BOX 400, RICHMOND, VA 23218-0400 OWNER ® TOWN OF VAIL USE THE WIDEWATERS GROUP P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 D R GGDD D DD D 18 E 19 E 10 E 25 E 26 E 9 E 12" 13 E 28 E 5'-4" 27 E 1'-6" 12 E 1'-6" 27 E 2'-0" 11 E 5'-6" 27 E 2'-0" 27 E 3'-0" 4'-6" 2'-6" 2 E 4 E 8'-0" 3 E 24" 6 E 1 E 6 E 2'-0" 24" 2'-0" 18" 17 E 16 E 15 E 14 E 1'-4" 2'-0" 20 E 5'-4" 23 E 16" 24 E 4'-6" 12" 5 E 7'-6" 7 E 3'-0" 16" 27 E 3'-8" 22 E 7'-0" 8 E 2'-0" 28 E 14" 12" 27 E 12" 36 E 2'-0" 29 E 30 E 4'-0" 31 E 2'-4" 29 E 3'-6" 32 E 3'-6" 1'-6" 2'-0" 2'-0" 1'-6" 1'-6" 1'-6" 1'-4" 27 E 27 E 35 E 27 E 34 E 27 E 33 E 28 E REFRIGERATED PREP TABLE DESCRIPTION E-12 ITEM 4 E-5 E-6 E-7 E-8 E-9 E-11 E-10 KEY E-2 E-1 E-4 E-3 ELECTRICAL ROUGH-IN KEY 1 120 1/4 PH. VOLTS HP KW 6.6 DR 12" CONN. AMPS HT. 120 EVAPORATOR COIL (COOLER) COMPRESSOR (COOLER) WALK-IN COOLER(LIGHTS) 29.3 29.1 29 1 15.0 JB 108" 108" JB 208 3 1.5 JB 120 1 4.4 (VERIFY W/SHOP DRAWINGS) (VERIFY W/SHOP DRAWINGS) (LOCATED ON ROOF BY MECH. CONTR.) 120 1 20.0 108" JB EXHAUST HOOD 120 1 4" JB 5 HEAT LAMPS 18 EXHAUST HOOD (LIGHT SWITCH) 18 EXHAUST HOOD (FAN SWITCH) 54" 54" 120 1 15.0 12"DR 7 HEATED PROOFER CABINET 120 1 12.0 10 STOCK POT KETTLE 208 1 13.7 4"DR 15 REFRIGERATED PREP TABLE 1.45 DOUBLE CONVECTION OVEN 17 1 (2)120 1/2 9.8 DR 24"/48" 18 3/4 REFRIGERATED EQUIPMENT STAND 1/5 DR 12"2 E-13 E-14 E-15 120 EVAPORATOR COIL (FREEZER) COMPRESSOR (FREEZER) WALK-IN FREEZER(LIGHTS) 29.4 29.2 29 1 15.0 JB 108" 108" JB 208 3 2.0 JB 208 1 12.4 (VERIFY W/SHOP DRAWINGS) (VERIFY W/SHOP DRAWINGS) (LOCATED ON ROOF BY MECH. CONTR.) E-16 E-17 120 1 10.0 108" JB 41 FIRE SYSTEM E-18 (VERIFY W/SHOP DRAWINGS) (VERIFY W/SHOP DRAWINGS) (VERIFY W/SHOP DRAWINGS) (VERIFY W/SHOP DRAWINGS) E-19 E-20 E-21 E-22 E-23 E-24 E-25 E-26 120 1 20.0 48"DR CONVENIENCE OUTLET E-27 120 1 20.0 12"DR CONVENIENCE OUTLET PIZZA PREP REFRIGERATOR 20 1 120 1/2 13.0 DR 12" DISHMACHINE 208 3 5.0 JB 14"31 1 120 5.7 2.2 (EC TO INTERWIRE (2) UNITS) 1.8 (EC TO BTC AND PROVIDE DR ON ITEM #14) WORKTOP FREEZER 25 1 120 1/3 6.1 DR 12" ICE MACHINE 27 1 120 15.2 JB 60" 31.3 DISHMACHINE (BOOSTER HEATER) 208 3 24.0 JB 14"31 120 1 10.0 48"JB 36 PIZZA OVEN (CONTROLS) 120 1 20.0 48"DR DIGITAL MENU BOARD 38 E-28 208 1 10.2 JB EXHAUST HOOD (EXHAUST FAN) EXHAUST HOOD (MUA UNIT) (LOCATED ON ROOF BY MECH. CONTR.) (LOCATED ON ROOF BY MECH. CONTR.)208 1 6.1 JB 3.0 2.0 4" JB E-29 E-30 E-31 E-32 E-33 50 FREEZER MERCHANDISER 48 REFRIG. OPEN MERCHANDISERS 49 REFRIGERATED WINE DISPLAY 52 POP-UP TOASTER E-34 E-35 E-36 53 STARBUCKS KIOSK (LIGHTS) 54 STARBUCKS KIOSK (ESPRESSO MACHINE) 55 STARBUCKS KIOSK (REFRIGRATOR) ATM MACHINE 120 1 20.0 12"DR 47 120 1 120 1 120 1 3/4 13.0 48"DR 1/3 3/4 5.4 9.0 48"DR 48"DR 120 1 2.0 16.6 48"DR 120 1 15.0 12"DR 208 1 48"JB 120 1 15.0 72" DR (VERIFY W/SHOP DRAWINGS - KIOSK LIGHTING) 2.8 18A 18B KEY TO SYMBOLS AND ABBREVIATIONS POUNDS PER SQUARE INCH CUBIC FEET PER MINUTE BRANCH TO CONNECTION BRITISH THERMAL UNITS PSI AFF BTU CFM BTC ABOVE FINISH FLOOR W IW FD SR FFD FS S G HW CW WASTE STEAM RETURN INDIRECT WASTE FLOOR DRAIN FUNNEL FLOOR DRAIN FLOOR SINK STEAM COLD WATER HOT WATER GAS SHOP WIRING FIELD WIRING CORD AND PLUG DISCONNECT SWITCH ELECTRIC CONNECTIONEC SWITCH HORSEPOWER KILOWATTS DUPLEX RECEPTACLE SINGLE RECEPTACLE ELECTRIC LIGHT PHASE VOLTS CYCLES JUNCTION BOX S 0 HP KW JB V CY PH SR DR THIS PLAN SHOWS ELECTRICAL REQUIREMENTS FOR FOOD SERVICE EQUIPMENT EQUIPMENT. ELECTRICAN TO FURNISH ALL TRIM ACCESSORIES, DISCONNECTS, ELECTRICAN TO ACCOMODATE ALL PREVAILING LOCAL ELECTRICAL CODES AS REQUIRED. ELECTRICAN TO INSTALL AND INTERWIRE HOOD OR VENTILATOR VAPOR-PROOF CONTRACTOR MUST MAKE ALLOWANCES FOR ANY APPLIED FINISH ADHERED TO ELECTRICAN TO DO ALL ROUGHING AND MAKE ALL FINAL CONNECTIONS TO CONTRACTORS,SWITCHES, RELAYS, ETC. AS REQUIRED. ALL CONVENIENCE OUTLETS TO BE MOUNTED HORIZONTALLY. ELECTRICAN TO FURNISH AND INSTALL CONDUITS AND SLEEVES FOR ALL WIRING AND CONDUIT TO BE CONCEALED. LIGHTS SUPPLIED BY KITCHEN EQUIPMENT CONTRACTOR. ALL DIMENSIONS FOR CONNECTIONS TO THE FIXTURES SHOULD COME OUT OF THE WALL OR PARTITION AT REAR. ALL DIMENSIONS ARE FROM FINISHED CONNECTIONS FROM ALL HOODS TO EXHAUST SYSTEM. AS REQUIRED FOR WALK-IN FREEZER. ELECTRICAN TO INSTALL AND INTERWIRE COMPRESSOR AND EVAPORATOR FLOOR, WALL OR COLUMNS. REFRIGERATION AND SODA LINES. ONLY. FOR ALL OTHER REQUIREMENTS, SUCH AS INTERIOR AND EXTERIOR LIGHTING, TOILET FACILITIES, EXHAUST FANS, WALL OUTLETS AND TELEPHONES, SEE ARCHITECTS PLAN. ELECTRICAL NOTES: FREEZER EVAPORATOR DRAIN LINE. ELECTRICAN TO PROVIDE AND INSTALL CONDENSATE HEAT TRACE TAPE FOR THE 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:31 PMENLARGED KITCHEN ELECTRICAL ROUGH IN PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K302 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 SCALE:1/4" = 1'-0"DRAWING REF: K1005AENLARGED KITCHEN ELECTRICAL ROUGH-IN PLAN13 12/22/2017 01/11/18 EP.O. BOX 400, RICHMOND, VA 23218-0400 OWNER ® TOWN OF VAIL USE THE WIDEWATERS GROUP P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:36 PMEXHAUST HOOD SHOP DRAWINGS - A THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K450 2211 N FRONTAGE RD, VAIL, COLORADO 81657 1312/01/2017CCD-09 13 12/22/2017 01/11/18 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:40 PMEXHAUST HOOD SHOP DRAWINGS - B THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K451 2211 N FRONTAGE RD, VAIL, COLORADO 81657 1312/01/2017CCD-09 13 12/22/2017 01/11/18 EP.O. BOX 400, RICHMOND, VA 23218-0400 OWNER ® TOWN OF VAIL USE THE WIDEWATERS GROUP P.O. BOX 400, RICHMOND, VA 23218-0400 ® 01/11/18 STORAGE STORAGE STORAGE PASTRY STORAGE STORAGE GRAB-N-GO LOCKABLE WINE DISPLAY GRAB-N-GO LOCKABLE WINE DISPLAY MADE MARKET ELEVATION - A MADE MARKET ELEVATION - B BAR EQUIPMENT ELEVATION BAR EQUIPMENT ELEVATION REFER TO SHEET A602 FOR MADE MARKET INFORMATION AND DETAILS 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:44 PMBAR AND MADE MARKET ELEVATIONS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS K550 2211 N FRONTAGE RD, VAIL, COLORADO 81657 13 12/01/2017 CCD-09 SCALE: 1/2" = 1'-0"4A BAR AND MADE MARKET ELEVATIONS 13 12/28/2017 01/11/18 ' ' ISSUE LOG KEY: # DATEISSUE LOG MECHANICAL SHEET INDEX TITLE MECHANICAL COVER SHEET AND SCHEDULESM0.0 PERMIT10.10.2017ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* β β β β PRESSURE REDUCING VALVE SHOCK ABSORBER STRAINER W/ BLOW-OFF VALVE SAFETY RELIEF VALVE VACUUM BREAKER PRESSURE GAUGE W/ PIG TAIL & COCK THERMOMETER PRESSURE - TEMP. TAP AIR VENT PIPE ANCHOR FLEXIBLE CONNECTOR PIPE EXPANSION JOINT PIPE UNION DOUBLE CHECK BACKFLOW PREVENTER PUMP & EQUIPMENT CONNECTOR TEMPERATURE CONTROL VALVE (2-WAY) DRAIN VALVE W/ HOSE END PLUG VALVE IN RISER FLOW BALANCING VALVE GATE OR GLOBE VALVE IN RISER FLOW CONTROL VALVE BALL VALVE PLUG OR BALANCING VALVE CHECK VALVE GLOBE VALVE BUTTERFLY VALVE VENTURI/FLOW INDICATOR TEMPERATURE CONTROL VALVE (3-WAY) SOLENOID VALVE 90° ELBOW UP TEE UP TEE DOWN SHUT OFF (BALL, GATE, BUTTERFLY) PIPING SYMBOLS 90° ELBOW DN S FLOW SWITCH HOSE BIBB WALL HYDRANT TEMPERATURE CONTROLLER OR SENSOR STEAM TRAP TEST CHAMBER STEAM TRAP: FT-FLOAT & THERMOSTATIC TD-THERMODYNAMIC IB-INVERTED BUCKET TS-THERMOSTATIC BP-BALANCED PRESSURE EQUIPMENT ABBREVIATIONS AIR HANDLING UNITAHU AIR SEPARATORAS BOILER (HOT WATER)B BASE BOARDBB BUFFER TANKBT CONSTANT VOLUME BOXCV DISHWASHER EXHAUST FANDEF ELECTRIC BASEBOARD HEATEREBH FURNACEF FAN COILFC FAN POWERED BOXFP GLYCOL FEEDERGF HUMIDIFIER HC HEATING COIL HP HEAT PUMP HX HEAT EXCHANGER KITCHEN EXHAUST FANKEF MAKE-UP AIR UNITMAU MOTOR CONTROL CENTERMCC MIXING VALVEMV PUMPP RETURN (OR RELIEF) AIR FANRF RADIANT ZONERZ SNOWMELT AREASA SUMP BASINSB SUPPLY FANSF STORAGE TANKST THERMOSTATIC MIXING VALVETMV UNIT HEATERUH VARIABLE VOLUME BOXVV WATER HEATERWH H CHILLERCH COOLING COILCC CIRC PUMPCP CABINET UNIT HEATERCUH COOLING TOWERCT DUCT COILDC ELECTRIC WATER HEATEREWH EVAPORATIVE COOLING UNITECU ENERGY RECOVERY UNITERU EXHAUST FANEF EXPANSION TANKET VARIABLE VOLUME BOX W/ REHEATVR REFERENCE SAMPLE FFI = FOR FURTHER INFORMATION FCT = FOR CONTINUATION RE: B/M400 FFI REFER TO: DRAWING NUMBER OR DIAGRAM LETTER SHEET NUMBER PLAN ABBREVIATIONS ABOVE FINISHED FLOOR AIR ADMITTANCE VALVE ABOVE FINISHED GRADE AUTOMATIC BUILDING CONTROL SYSTEM BACK DRAFT DAMPER BUILDING AAV AFF AFG AUTO BCS BDD BLDG BETWEEN COMMON (OR CLOSED) COMBUSTION AIR CONTROLS CONTRACTOR CONTINUATION DESIGN BUILD B/N C CA CC CDBBC CUBIC FEET PER MINUTE (AIR FLOW RATE) CAST IN PLACE CEILING (OR COOLING) CONCRETE CONDENSATE CONNECT (OR CONNECTION) CONTRACTOR CFM CIP CLG CONC COND CONN CONTR'R CLEANOUT TO GRADECOTG DOMESTIC HOT WATER RECIRC EXISTING DWR (E) EXHAUST AIREA ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENTERING WATER TEMPERATURE EAT EC EXH EXHAUST EWT GENERAL CONTRACTOR GROUND HEAT EXCHANGER GC GHX GALLONS PER MINUTE (WATER FLOW RATE)GPM HORSEPOWER HOT WATER IN LIEU OF HP HW ILO KILOWATTSKW LEAVING AIR TEMPERATURE LINEAR FOOT LEAVING WATER TEMPERATURE LAT LF LWT MECHANICAL CONTRACTORMC MANUFACTURER MOTOR OPERATED DAMPER NEW MFG MOD (N) NORMALLY CLOSEDNC NATIONAL ELECTRIC CODE NOT IN CONTRACT NORMALLY OPEN NEC NIC NO OUTSIDE AIROA OPPOSED BLADE VOLUME DAMPER ON CENTER OBD OC OUTSIDE AIROSA RETURN AIR REQUIRED RA REQ'D REQUIREMENTSREQ'MTS SUPPLY AIR SQUARE FOOT (FEET) SA SF STATIC PRESSURESP STAINLESS STEEL THROW-AWAY (TRANSFER AIR) TYPICAL SS TA TYP UNLESS NOTED OTHERWISEUNO WALL CLEANOUTWCO WITH REGARD TO WATER COOLED TRANSFER WRT W/C XFR DIAMETERØ BY CONTRACTOR COLD WATERCW HOT WATER RECIRCHWC ABOVEABV BELOW FINISHED GRADEBFG DOMESTIC WATER DOMESTIC HOT WATER DW DHW DOWNDN DOMESTIC HOT WATER RECIRCDHR COMBINATION FIRE/SMOKE DAMPER FURNISHED BY OWNER FSD FBO FLOOR CLEANOUTFCO FOR CONTINUATIONFCT FD FIRE DAMPER REFER TO:RE: WITHW/ CLEANOUTCO FUTURE(F) FREE AREAFA FFI FOR FURTHER INFORMATION WITHOUTW/O VENT THRU ROOFVTR NOTES 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. PLAN SYMBOLS CONTROL PANEL/RADIANT MANIFOLD CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR DIAGRAM CONTINUATION REFERENCE PLUMBING/HVAC RISER POINT OF NEW CONNECTION DUCT STATIC PRESSURE SENSOR ROOM PRESSURE SENSOR EMERGENCY POWER OFF SWITCH ACCESS PANEL SNOWMELT MANIFOLD SECTION CUT LETTER/SHEET SHOWN ON POINT OF DISCONNECTION - SP CO2 EPO P CO -- - P THERMOSTAT HUMIDISTAT REMOTE TEMPERATURE SENSOR T S H H B W H TC FS ROOF DRAIN FLOOR DRAIN FLOOR SINK HORIZONTAL CLEANOUT VERTICAL CLEANOUT DECK/ROOF DRAIN ABOVE PIPING DESIGNATIONS HEATING WATER SUPPLY (HIGH TEMP) HEATING WATER RETURN (HIGH TEMP) CONDENSER RETURN NATURAL GAS MEDIUM PRESSURE GAS DOMESTIC WATER DOMESTIC HOT WATER DOMESTIC HOT WATER (TEMP. SHOWN) DHW RECIRCULATION FIRE LINE PLUMBING VENT PIPE WASTE PIPE STORM DRAIN PIPE STORM DRAIN OVERFLOW GREASE WASTE PIPE SECONDARY DRAIN SAND AND OIL WASTE HEATING WATER SUPPLY (LOW TEMP) HEATING WATER RETURN (LOW TEMP) HEATING WATER SUPPLY HEATING WATER RETURN DRAIN PIPE FUEL OIL SUPPLY FUEL OIL RETURN GREASE VENT FUEL OIL VENT FUEL OIL FILL CONDENSER SUPPLY PLUMBING PIPING NON-SOFTENED DOMESTIC WATER CR CS HWR HWS HWR(LT) HWS(LT) HWR(HT) HWS(HT) D MG G FOF FOV FOR FOS CW HW HWC NS 140° HW GV SO SD ST GW V W ST(OF) F HYDRONIC PIPING SUMP PUMPSP MECHANICAL SYSTEMS LEGEND ABOVE SEA LEVEL PROJECT ALTITUDE 8150' M0.1 MECHANICAL ROOM PLANSM2.0 MECHANICAL SPECIFICATIONS SNOWMELT SUPPLY SNOWMELT RETURN FLOOR COOLING SUPPLY FLOOR COOLING RETURNFCR FCS SMS SMR M1.1 GAS PIPING SITE PLAN βM1.0 SNOWMELT SYSTEM SITE PLAN MECHANICAL DIAGRAMSM3.0 β β BOILER SCHEDULE MARK SERVICE BOILER TYPE FUEL TYPE TURNDOWN RATIO HEATING CAPACITY L.W.T. (°F) E.W.T. (°F) BURNER VENT TYPE MANUFACTURER* & MODEL #ACCESSORIES REMARKSINPUT @ S.L. (MBH) OUTPUT @ ALT. MINIMUM A.F.U.E.WATTS VOLT/ PH B-2 HEATING WATER FIRE TUBE CONDENSING NAT. GAS 7:1 850 800 97 180 160 1440 120/1 6" CAT IV DIRECT LOCHINVAR FTX850N A B B-1 HEATING WATER EXISTING NAT. GAS N/A 1800 - 80 180 160 -1201 B VENT CAT 1 EXISTING TO REMAIN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - MANUFACTURERS: * N/A GENERAL NOTES: A: MOTORIZED ISOLATION VALVE; VARIABLE SPEED BOILER CIRCULATOR; CONDENSATE NEUTRALIZATION KIT; FLOW SWITCH. B: DIRECT VENT TO EXTERIOR; COMBUSTION AIR FROM ROOM. HEAT EXCHANGER SCHEDULE MARK SERVICE TYPE SIDE GPM FLUID E.W.T. (°F) L.W.T. (°F) MAX PRESSURE DROP (PSI) FOULING FACTOR HEAT TRANSFER (MBH) MANUFACTURER* & MODEL #ACCESSORIES REMARKS HX-1 SNOWMELT BRAZED PLATE HOT 30 20% GLYCOL 180 150 6 1.0 500 TRIANGLE TUBE TB10T - - COLD 30 50% GLYCOL 110 140 7.3 - - - HOT - - - - - - - - - - COLD - - - - - MANUFACTURERS: * B&G, PATTERSON-KELLY, TACO, TRANTER GENERAL NOTES: A: B: PUMP SCHEDULE MARK SERVICE TYPE GPM TDH (FT) FLUID MOTOR MANUFACTURER* & MODEL #ACCESSORIES REMARKSWATTS RPM VOLT/ PH BP-1 EXISTING IN-LINE - -20% PROP GLYCOL - - - EXISTING TO REMAIN N/A N/A BP-2 B-2 IN-LINE 55 5 20% PROP GLYCOL 600 VARIABLE SPEED 120/1 PROVIDED WITH BOILER - - SMHXP-1 SNOWMELT HEAT EXCHANGER IN-LINE 60 20 20% PROP GLYCOL 640 3 SPEED 208/3 GRUNDFOS UPS 50-80/4 F CONTROL RELAY - SP-1 SNOWMELT IN-LINE 60 40 50% PROP GLYCOL 1300 3 SPEED 208/3 GRUNDFOS UPS 50-160 F CONTROL RELAY - - - - - - - - - - - - - MANUFACTURERS: * N/A GENERAL NOTES: A: B: MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE MARK SERVICE TYPE CAPACITY ELECTRICAL MANUFACTURER* & MODEL #ACCESSORIES REMARKSWATTS VOLT/ PH AS-2 SNOWMELT AIR SEPERATOR IN-LINE LINE SIZE N/A N/A TACO AC025-125 - - EXT-2 SNOWMELT EXPANSION TANK BLADDER 23/10 N/A N/A TACO CX84-125 - - GF-2 SNOWMELT GLYCOL FEEDER N/A 55 GALLON 84 120/1 AXIOM SF100 LOW LEVEL ALARM PANEL - MANUFACTURERS: * GENERAL NOTES: A: B: Designed: Reviewed: Project No: 9714.03 Issued: PERMIT SET 10.10.2017 \\BGCE-RSNAS\DATA\BGPROJECTS\9714.03 DOUBLETREE VAIL-EXISTIG SNOWMELT SYTEM UPGRADE & EXPANSION\DRAWINGS\9714.03M0.0.DWG10.11.172:30:14 PM Scale: As ShownDOUBLETREE - VAILSNOW MELT SYSTEM EXPANSION & UPGRADEVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ΛbgbuildingworksΛcom10.10.2017 MECHANICAL COVER SHEET AND SCHEDULES DAL DAL M0.0 01/11/18 1. Do not scale drawings. Verify dimensions in field prior to commencement of work. Refer to architectural drawings for all dimensions. 2. Inasmuch as design for remodel and/or rehabilitation requires that certain assumptions be made regarding existing conditions, and because some of these assumptions cannot be verified without destroying otherwise adequate or serviceable portions of the building, the Engineer cannot assure the Owner or the contractor that the professional consulting services herein encompass all contingencies. Field coordination during construction is imperative. Make reasonable allowances for unseen conditions. 3. Be responsible to field verify existing equipment remaining to be connected to new or existing systems. Provide ductwork, piping, controls, diffusers, etc., as required to restore continuity of system(s), or to make new work meet existing conditions, whether indicated or not. 4. Subcontractor shall verify existence and location of all utility services and coordinate as required by their respective area of the construction, notifying the prime contractor of variations or conflicts. 5. If not specifically defined in these construction documents, materials and/or equipment shall be identified by the subcontractor with sufficient time to allow selection, purchase, and delivery to maintain construction schedule. 6. Provide mechanical demolition as required. Dispose of all removed piping, ductwork, etc. unless noted otherwise. 7. Verify exact locations of existing and new underground utilities, piping, and raceway systems prior to trenching. Contractor shall obtain and verify exact utility company drawings and requirements. 8. System shown in light line weight is existing, new indicated by heavier line weight, except where noted. Systems to be removed, are shown hatched. 9. Offset new systems as necessary to accommodate structure and existing equipment. 10. All existing support rods and straps supporting systems that are removed to allow room for installation of new system shall be relocated and reinstalled, or replaced if damaged. 11. It is the contractor's responsibility to perform his/her work in conformance with all applicable codes, ordinances and life safety features as required by local, state, or national authorities. The contractor shall verify with the architect if modification of his/her work is required for compliance. 12. All work of all trades must be in strict compliance, or exceed the minimum material and method requirements of the 2015 version of the International Building, Mechanical, Plumbing, Energy Conservation, and Fire Codes, and the 2014 National Electrical Code, most current NFPA, all local ordinances and amendments and manufacturer's installation recommendations. If a conflict between those publications exists, the most stringent requirement shall apply. 13. Pay for and secure all required permits and inspections. Prior to final payment, turn over to owner all certificates of completion. 14. Warranty the installation against defects in materials and workmanship. The warranty shall be for a period of one year after Owner's acceptance. Defects shall be promptly remedied without cost to the Owner. 15. Submit record documents to owner. Documents shall include all addendum items, change orders, alterations, re-routings, etc. 16. Systems shall be complete, operable, and ready for continuous operation prior to acceptance by the Owner. 17. Systems shall be tested for proper operation. Perform at a minimum all code required tests or systems. If tests of work are defective, contractor shall make corrections necessary at no additional cost to Owner. 18. All materials and/or equipment shall be handled and installed as per manufacturer's specifications and recommendations. 19. Provide necessary trenching, backfill, excavation, supports, saw-cutting and patching, concrete/paving, etc., as required. Backfill trenches in 6β layers and to 90% compaction and patch to match grade. 20. Provide 4β high concrete equipment pads beneath floor mounted mechanical equipment, in addition to any base assemblies required or recommended by the manufacturer. 21. Fire stopping requirement. Penetrations through rated walls and floors shall be sealed with a material capable of preventing the passage of flames and hot gasses when subjected to the requirements of the test standard specific for fire stops ASTM-E-814. Acceptable materials include: DOW corning RTV fire stop foam for bare pipe, metal conduit, and electrical cable; 3M Fire Dam 150 caulk for bare pipe, metal conduit, and building construction gaps; 3M CP-25 caulk and FS-195 intumescent strips for insulated pipes, plastic pipe or conduit, and electrical cable. Submit UL listed application data for each type of penetration encountered. 22. Coordinate architectural, structural, mechanical, fire protection, electrical, landscaping, and interior design drawings prior to installation. 23. Carefully verify electrical service voltage and phase available. Coordinate power connections for new boiler, pumps, and controls with electrical contractor. 24. Submit a written balance report by a NEBB or AABC certified balancing contractor. Balancing procedures shall be in accordance with NEBB or AABC guidelines for proportional balance. Submit report on standard NEBB forms or submit forms for review prior to balancing. Measurements shall include water flow at all flow measurement stations; inlet and outlet pressure at pumps with flow calculated from the pump curve; water flow, temperature drop, and pressure drop at all coils. 25. Provide ¼β galvanized mesh screen on all combustion air ducts or openings. 26. Support pipe with rod and clevis, ring hangers, trapeze, or clamps. No pipe tape or strapping allowed. All hangers shall be sized for OD of insulation, if any. Protect insulated lines with 20 ga sheet metal shields and provide calcium silicate insulation inserts for all insulated piping. Maintain vapor barrier on all cold lines. Isolate bare copper lines from hangers with Vibrasorb or equivalent, copper coated hangers are not sufficient, wrapping pipe with tape not acceptable. 27. Copper pipe valves and specialties A. Gate valves - bronze, class 125, 200 lb. w.o.g. B. Ball valves - bronze, class 125, 600 lb. w.o.g. C. Check valves - bronze, class 125, 200 lb. w.o.g. D. Balancing valves - 125 psi w.p. For 250 degree Fahrenheit service tight shutoff, Tour and Anderson STA, Armstrong CBV, Gerand, or Flowset, B&G circuit setter. E. Direct unions: Furnish and install a dielectric union at each connection between dissimilar metals. 28. Provide expansion joints or loops on all snowmelt and heating water piping runs in excess of 50 feet and in accordance with the manufacturer's recommendations. 29. Fill heating water system with 30% propylene glycol/water solution and fill snowmelt system with 50% propylene glycol/water solution. 30. Grade and valve all heating and snowmelt water piping with 3/4β hose end valves to permit complete drainage of the system. Vent all high points in equipment rooms as necessary with automatic air vents piped to convenient drain. All high points in system outside of equipment rooms with combination automatic/manual air vents as required to relieve air in the system. 31. Provide plastic grommets on all heating water piping passing through wood joists and studs. 32. Materials; hydronic piping A. Above grade, up through 2-1/2β: schedule 40 steel pipe with malleable iron threaded fittings, or Type βLβ copper tube with wrought copper fittings and 95-5 no lead solder. B. Below grade, all sizes: jacketed, pre-insulated piping, Uponor EcoFlex thermal single or twin hePEX or equal. All buried pipe shall be surrounded with 4β of clean sand. 1) Option for piping 1-1/4β and smaller: Type βKβ soft annealed copper tube, single length to avoid fittings, (wrought copper fittings where unavoidable) and 1100 degree Fahrenheit solder insulate with 1β thick closed cell elastomeric insulation. C. Snowmelt serpentine tubing: 1) All tubing to be cross-linked polyethylene (PEX) with an oxygen diffusion barrier. Tubing to be rated for continuous operation of 100 psig and a temperature suitable for the specific application. Factory manifolds shall be equipped with loop valves and zone valves per controls requirements. Systems shall be capable of withstanding temperatures 180 degree f to 230 degree f for limited periods of time. Install piping and manifold in accordance with the manufacturer's recommendations. 2) Snowmelt piping shall be placed on 9 inch centers. Tube diameter, nominal 3/4". Wirsbo hePEX or approved equivalent. 33. Drain and receptor piping for combustion condensate--not buried--type: schedule 40 solid-wall PVC, PVC fittings, and PVC cement. 34. Indoor piping insulation - insulate all new heating water and snowmelt piping with UL approved, white, all service, mineral fiber, snap-on, pipe insulation. Insulate fittings with mineral fiber blanket insulation and pre-molded PVC covers. All materials shall have a smoke developed rating of 50 or less and a flame spread rating of 25 or less. Provide calcium silicate thermal insert at hangers and supports. Insulation shall pass uninterrupted through hangers. Vapor barriers shall be continuous, and sealed with βnon-breathingβ vapor barrier mastic on piping operating at temperatures below ambient. All raw edges of insulation shall be neatly trimmed and sealed with mastic. A. Insulation thickness below based on insulation conductivity value not exceeding 0.27 Btu*in/(hr*ft^2*°F): 1) Heating water (less than 200°F) - NPS 1.25 and less, 1.5β thick; NPS 1.5 and greater, 2β thick. Runouts within 4 feet of terminal and 1β pipe diameter or less, 1β thick. 35. Identification: Label all new piping and equipment. Provide full band or strip type markers and flow arrows on piping. Provide engraved plastic valve tags with valve number and attach with standard chain or s-hooks. Provide engraved plastic sign on or near specified equipment. 36. GAS PIPING, TUBES, AND FITTINGS A. Steel Pipe: ASTM A 53/A 53M, black steel, Schedule 40, Type E or S, Grade B. 1) Malleable-Iron Threaded Fittings: ASME B16.3, Class 150, standard pattern. 2) Wrought-Steel Welding Fittings: ASTM A 234/A 234M for butt welding and socket welding. 3) Unions: ASME B16.39, Class 150, malleable iron with brass-to-iron seat, ground joint, and threaded ends. 4) Protective Coating for Underground Piping: Factory-applied, three-layer coating of epoxy, adhesive, and PE. a. Joint Cover Kits: Epoxy paint, adhesive, and heat-shrink PE sleeves. B. Corrugated, Stainless-Steel Tubing: Comply with ANSI/IAS LC 1. 1) Coating: PE with flame retardant. a. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. Flame-Spread Index: 25 or less. Smoke-Developed Index: 50 or less. 2) Fittings: Copper-alloy mechanical fittings with ends made to fit and listed for use with corrugated stainless-steel tubing and capable of metal-to-metal seal without gaskets. Include brazing socket or threaded ends complying with ASME B1.20.1. 3) Striker Plates: Steel, designed to protect tubing from penetrations. 4) Manifolds: Malleable iron or steel with factory-applied protective coating. Threaded connections shall comply with ASME B1.20.1 for pipe inlet and corrugated tubing outlets. 5) Operating-Pressure Rating: 5 psig (34.5 kPa). C. Annealed-Temper Copper Tube: Comply with ASTM B 88, Type K (ASTM B 88M, Type A) or ASTM B 88, Type L (ASTM B 88M, Type B). 1) Copper Fittings: ASME B16.22, wrought copper, and streamlined pattern. 2) Flare Fittings: Comply with ASME B16.26 and SAE J513. a. Copper fittings with long nuts. b. Metal-to-metal compression seal without gasket. c. Dryseal threads complying with ASME B1.20.3. 3) Protective Coating for Underground Tubing: Factory-applied, extruded PE a minimum of 0.022 inch (0.56 mm) thick. D. PE Pipe: ASTM D 2513, SDR 11. 1) PE Fittings: ASTM D 2683, socket-fusion type or ASTM D 3261, butt-fusion type with dimensions matching PE pipe. 2) PE Transition Fittings: Factory-fabricated fittings with PE pipe complying with ASTM D 2513, SDR 11; and steel pipe complying with ASTM A 53/A 53M, black steel, Schedule 40, Type E or S, Grade B. 37. GAS PIPING SPECIALTIES A. Appliance Flexible Connectors: 1) Outdoor, Appliance Flexible Connectors: Comply with ANSI Z21.75. 2) Corrugated stainless-steel tubing with polymer coating. 3) Operating-Pressure Rating: 0.5 psig (3.45 kPa). 4) End Fittings: Zinc-coated steel. 5) Threaded Ends: Comply with ASME B1.20.1. 6) Maximum Length: 72 inches (1830 mm.) 38. GAS PIPING JOINING MATERIALS A. Joint Compound and Tape: Suitable for natural gas. B. Welding Filler Metals: Comply with AWS D10.12/D10.12M for welding materials appropriate for wall thickness and chemical analysis of steel pipe being welded. C. Brazing Filler Metals: Alloy with melting point greater than 1000 deg F (540 deg C) complying with AWS A5.8/A5.8M. Brazing alloys containing more than 0.05 percent phosphorus are prohibited. 39. MANUAL GAS SHUTOFF VALVES A. General Requirements for Metallic Valves, NPS 2 (DN 50) and Smaller: Comply with ASME B16.33. 1) CWP Rating: 125 psig (862 kPa). 2) Threaded Ends: Comply with ASME B1.20.1. 3) Dryseal Threads on Flare Ends: Comply with ASME B1.20.3. 4) Listing: Listed and labeled by an NRTL acceptable to authorities having jurisdiction for valves 1 inch (25 mm) and smaller. 5) Service Mark: Valves 1-1/4 inches (32 mm) to NPS 2 (DN 50) shall have initials "WOG" permanently marked on valve body. B. One-Piece, Bronze Ball Valve with Bronze Trim: MSS SP-110. 1) Body: Bronze, complying with ASTM B 584. 2) Ball: Chrome-plated brass. 3) Stem: Bronze; blowout proof. 4) Seats: Reinforced TFE; blowout proof. 5) Packing: Separate packnut with adjustable-stem packing threaded ends. 6) Ends: Threaded, flared, or socket as indicated in "Underground Manual Gas Shutoff Valve Schedule" and "Aboveground Manual Gas Shutoff Valve Schedule" Articles. 7) CWP Rating: 600 psig (4140 kPa). 8) Listing: Valves NPS 1 (DN 25) and smaller shall be listed and labeled by an NRTL acceptable to authorities having jurisdiction. 9) Service: Suitable for natural-gas service with "WOG" indicated on valve body. C. Two-Piece, Full-Port, Bronze Ball Valves with Bronze Trim: MSS SP-110. 1) Body: Bronze, complying with ASTM B 584. 2) Ball: Chrome-plated bronze. 3) Stem: Bronze; blowout proof. 4) Seats: Reinforced TFE; blowout proof. 5) Packing: Threaded-body packnut design with adjustable-stem packing. 6) Ends: Threaded, flared, or socket as indicated in "Underground Manual Gas Shutoff Valve Schedule" and "Aboveground Manual Gas Shutoff Valve Schedule" Articles. 7) CWP Rating: 600 psig (4140 kPa). 8) Listing: Valves NPS 1 (DN 25) and smaller shall be listed and labeled by an NRTL acceptable to authorities having jurisdiction. 9) Service: Suitable for natural-gas service with "WOG" indicated on valve body. D. Two-Piece, Regular-Port Bronze Ball Valves with Bronze Trim: MSS SP-110. 1) Body: Bronze, complying with ASTM B 584. 2) Ball: Chrome-plated bronze. 3) Stem: Bronze; blowout proof. 4) Seats: Reinforced TFE. 5) Packing: Threaded-body packnut design with adjustable-stem packing. 6) Ends: Threaded, flared, or socket as indicated in "Underground Manual Gas Shutoff Valve Schedule" and "Aboveground Manual Gas Shutoff Valve Schedule" Articles. 7) CWP Rating: 600 psig (4140 kPa). 8) Listing: Valves NPS 1 (DN 25) and smaller shall be listed and labeled by an NRTL acceptable to authorities having jurisdiction. 9) Service: Suitable for natural-gas service with "WOG" indicated on valve body. E. Bronze Plug Valves: MSS SP-78. 1) Body: Bronze, complying with ASTM B 584. 2) Plug: Bronze. 3) Ends: Threaded, socket, as indicated in "Underground Manual Gas Shutoff Valve Schedule" and "Aboveground Manual Gas Shutoff Valve Schedule" Articles. 4) Operator: Square head or lug type with tamperproof feature where indicated. 5) Pressure Class: 125 psig (862 kPa). 6) Listing: Valves NPS 1 (DN 25) and smaller shall be listed and labeled by an NRTL acceptable to authorities having jurisdiction. 7) Service: Suitable for natural-gas service with "WOG" indicated on valve body. F. PE Ball Valves: Comply with ASME B16.40. 1) Body: PE. 2) Ball: PE. 3) Stem: Acetal. 4) Seats and Seals: Nitrile. 5) Ends: Plain or fusible to match piping. 6) CWP Rating: 80 psig (552 kPa). 7) Operating Temperature: Minus 20 to plus 140 deg F (Minus 29 to plus 60 deg C). 8) Operator: Nut or flat head for key operation. 9) Include plastic valve extension. 10) Include tamperproof locking feature for valves where indicated on Drawings. G. Valve Boxes: 1) Cast-iron, two-section box. 2) Top section with cover with "GAS" lettering. 3) Bottom section with base to fit over valve and barrel a minimum of 5 inches (125 mm) in diameter. 4) Adjustable cast-iron extensions of length required for depth of bury. 5) Include tee-handle, steel operating wrench with socket end fitting valve nut or flat head, and with stem of length required to operate valve. 40. GAS PIPING - LABELING AND IDENTIFYING A. Detectable Warning Tape: Acid- and alkali-resistant, PE film warning tape manufactured for marking and identifying underground utilities, a minimum of 6 inches (150 mm) wide and 4 mils (0.1 mm) thick, continuously inscribed with a description of utility, with metallic core encased in a protective jacket for corrosion protection, detectable by metal detector when tape is buried up to 30 inches (750 mm) deep; colored yellow. B. Install detectable warning tape directly above gas piping, 12 inches (300 mm) below finished grade, except 6 inches (150 mm) below subgrade under pavements and slabs. 41. OUTDOOR GAS PIPING INSTALLATION A. Comply with the International Fuel Gas Code for installation and purging of natural-gas piping. B. Install underground, natural-gas piping buried at least 18inches below finished grade. 1) If natural-gas piping is installed less than 12 inches (900 mm) below finished grade, install it in containment conduit. C. Install underground, PE, natural-gas piping according to ASTM D 2774. D. Steel Piping with Protective Coating: 1) Apply joint cover kits to pipe after joining to cover, seal, and protect joints. 2) Repair damage to PE coating on pipe as recommended in writing by protective coating manufacturer. 3) Replace pipe having damaged PE coating with new pipe. E. Copper Tubing with Protective Coating: 1) Apply joint cover kits over tubing to cover, seal, and protect joints. 2) Repair damage to PE coating on pipe as recommended in writing by protective coating manufacturer. 3) Install fittings for changes in direction and branch connections. F. OUTDOOR PIPING SCHEDULE 1) Underground natural-gas piping shall be one of the following: a. PE pipe and fittings joined by heat fusion; service-line risers with tracer wire terminated in an accessible location. b. Steel pipe with wrought-steel fittings and welded joints. Coat pipe and fittings with protective coating for steel piping. c. Annealed-temper copper tube with wrought-copper fittings and brazed joints. Coat pipe and fittings with protective coating for copper tubing. 2) Aboveground natural-gas piping shall be one of the following: a. Steel pipe with malleable-iron fittings and threaded joints. b. Steel pipe with wrought-steel fittings and welded joints. c. Annealed-temper copper tube with wrought-copper fittings and brazed joints. 42. GAS VALVE INSTALLATION A. Install manual gas shutoff valve for each gas appliance ahead of corrugated stainless-steel tubing or copper connector. B. Install underground valves with valve boxes. C. Install anode for metallic valves in underground PE piping. D. ABOVEGROUND MANUAL GAS SHUTOFF VALVE SCHEDULE 1) Valves for pipe sizes NPS 2 (DN 50) and smaller at service meter shall be one of the following: a. One-piece, bronze ball valve with bronze trim. b. Two-piece, full -port, bronze ball valves with bronze trim. c. Bronze plug valve. 2) Distribution piping valves for pipe sizes NPS 2 (DN 50) and smaller shall be one of the following: a. One-piece, bronze ball valve with bronze trim. b. Two-piece, full regular-port, bronze ball valves with bronze trim. c. Bronze plug valve. 3) Valves in branch piping for single appliance shall be one of the following: a. One-piece, bronze ball valve with bronze trim. b. Two-piece, full -port, bronze ball valves with bronze trim. c. Bronze plug valve 43. GAS PIPING JOINT CONSTRUCTION A. Ream ends of pipes and tubes and remove burrs. B. Remove scale, slag, dirt, and debris from inside and outside of pipe and fittings before assembly. C. Threaded Joints: 1) Thread pipe with tapered pipe threads complying with ASME B1.20.1. 2) Cut threads full and clean using sharp dies. 3) Ream threaded pipe ends to remove burrs and restore full inside diameter of pipe. 4) Apply appropriate tape or thread compound to external pipe threads unless dryseal threading is specified. 5) Damaged Threads: Do not use pipe or pipe fittings with threads that are corroded or damaged. Do not use pipe sections that have cracked or open welds. D. Welded Joints: 1) Construct joints according to AWS D10.12/D10.12M, using qualified processes and welding operators. 2) Bevel plain ends of steel pipe. 3) Patch factory-applied protective coating as recommended by manufacturer at field welds and where damage to coating occurs during construction. E. Brazed Joints: Construct joints according to AWS's "Brazing Handbook," "Pipe and Tube" Chapter. F. Flared Joints: Cut tubing with roll cutting tool. Flare tube end with tool to result in flare dimensions complying with SAE J513. Tighten finger tight, then use wrench. Do not overtighten. G. PE Piping Heat-Fusion Joints: Clean and dry joining surfaces by wiping with clean cloth or paper towels. Join according to ASTM D 2657. 1) Plain-End Pipe and Fittings: Use butt fusion. 2) Plain-End Pipe and Socket Fittings: Use socket fusion. 44. GAS PIPING CONNECTIONS A. Connect to utility's gas main according to utility's procedures and requirements. B. Install natural-gas piping electrically continuous, and bonded to gas appliance equipment grounding conductor of the circuit powering the appliance according to NFPA 70. C. Install piping adjacent to appliances to allow service and maintenance of appliances. D. Connect piping to appliances using manual gas shutoff valves and unions. Install valve within 72 inches (1800 mm) of each gas-fired appliance and equipment. Install union between valve and appliances or equipment. E. Sediment Traps: Install tee fitting with capped nipple in bottom to form drip, as close as practical to inlet of each appliance. MECHANICAL SPECIFICATIONS Designed: Reviewed: Project No: 9714.03 Issued: PERMIT SET 10.10.2017 \\BGCE-RSNAS\DATA\BGPROJECTS\9714.03 DOUBLETREE VAIL-EXISTIG SNOWMELT SYTEM UPGRADE & EXPANSION\DRAWINGS\9714.03M0.1.DWG10.11.172:30:25 PM Scale: As ShownDOUBLETREE - VAILSNOW MELT SYSTEM EXPANSION & UPGRADEVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ΛbgbuildingworksΛcom10.10.2017 MECHANICAL SPECIFICATIONS DAL DAL M0.1 01/11/18 HOT WATER BALANCING COCK THERMOMETER SUPPLY HOT WATER RETURN THREE-WAY AUTOMATIC CONTROL VALVE TERMINAL UNIT HOT WATER COIL CONCEALED REGULATOR KIT CEILING DIFFUSER RIGID DUCTWORK FLEXIBLE DUCTWORK SCREWS AND WIRE (50'-0" RACK & PINION FLEXIBLE CASING MAXIMUM) OPERATOR ADJUSTABLE PRIOR TO INSTALLATION. 1) SPANNER WRENCH ROUND DAMPER COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT COVER PLATE NOTE: VOLTS/PHASE DESIGNATION MODELTYPE SIZE (FEET)GPM %EFF. HP RPM HEAD MOTOR NOTESSERVICE IMPELLER (INCHES) RATE FLOW 208/3 P-1 INLINE B & G E-90 25 6 27 1/2 1800 TERMINAL REHEAT SECONDARY LOOP 1AAB 5 NOTES: PUMP SCHEDULE 1 1. PUMP SHALL BE ALL BRONZE CONSTRUCTION AND HAVE 316 STAINLESS STEEL SHAFT. 2. PROVIDE DISCONNECT. 2 DESIGNATION SERVICE TYPE AIR PATTERN FINISH FACE SIZE / FRAME MODELNECK SIZE AIR DISTRIBUTION DEVICE SCHEDULE ACCESSORIES 1 NOTES AND ACCESSORIES: R-1 GRILLE RETURN TITUS PAR R-2 GRILLE RETURN - S-1 TWO WAY COLOR BY ARCH SLOT SUPPLY 48" LENGTH TITUS ML-39 1 3 PAINT VISIBLE PLENUM OR DUCTWORK BEHIND GRILLE FLAT BLACK. TITUS PAR SEE PLAN SEE PLAN ADJUST PATTERN CONTROLLERS AS SHOWN. PROVIDE OPPOSED BLADE DAMPER. SEE PLAN- 3 S-3 HORIZONTALSUPPLY SEE PLANS / SURFACE TITUS CT 480 LINEAR BAR SEE PLAN 4 PROVIDE MOUNTING FRAME AS REQUIRED FOR INSTALLATION. REFER TO ARCH REFLECTED CEILING PLANS. 3 3 2 4 4 5 4 S-4 SUPPLY TITUS 300 RS SEE PLAN 1 2 4 5 2 SLOT, 1 INCH SLOT WIDTH WITH INSULATED PLENUM BOOT. S-2 ROUNDSUPPLY 24x24 / SURFACE OR LAY-IN TITUS OMNI PLAQUE FACE SEE PLAN 4COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH COLOR BY ARCH SEE PLANS / SURFACEHORIZONTALSIDE WALL 24x24 / SURFACE OR LAY-IN E-1 GRILLE TITUS PAR - SEE PLAN COLOR BY ARCH 24x24 / SURFACE OR LAY-IN EXHAUST 3 4 24x12 / SURFACE OR LAY-IN ELECTRIC WALL HEATER SCHEDULE LOCATION EWH-1 DESIGNATION BTU/HR CAPACITY PHASE VOLTS/ KW CFM °F E.A.T. AMPS HZ MOTOR MODEL NUMBER MAKE AND NOTES 27,400 8.0 240 / 1 QMARK EFQ8004 VESTIBULE 400 6033.3 40 NOTES: 1. INSTALL USING RECESS MOUNT. 2. PROVIDE UNIT MOUNTED DISCONNECT SWITCH. 3. PROVIDE BUILT-IN, TAMPER-PROOF THERMOSTAT. 1 2 3 TERMINAL BOX SCHEDULE VAV AIR VALVE DESIGNATION TERMINAL BOX MIN. CFM MAX. CFM INCH DIA. SIZE INLET CFM IN. W.G. STATIC PRESS. MAX. EWT EAT HOT WATER HEATING COIL GPM MAKE MODEL °F NOTES / ACCESSORIES LWT LAT °F °F °F WPD FT WG MAX. 1 85 420 6 170 540 8 160 310 6 335 595 10 85 420 6 130 430 6 145 375 6 VAV-1 220 500 8 0.25 180 0.5 0.3 DESV TITUS 335 755 8 168 152 157 156 167 158 158 152 144 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 91.7 85.8 101.7 99.6 95.4 110.0 100.7 97.3 105.0 0.9 PERFORMANCE BASED ON ACCORDANCE WITH ASHRAE 120, AHRI 880, AND ELEVATION OF 8,000 FEET. 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 SPACE TEMPERATURES ARE BASED ON 76°F COOLING /72°F HEATING DURING OCCUPIED HOURS; 85°F COOLING / 65°F HEATING DURING UNOCCUPIED HOURS. PROVIDE WITH WIRELESS, STAND-ALONE CONTROLLER COMPATIBLE WITH THE AHU AND USING BACNET PROTOCOL. VAV-2 VAV-3 VAV-4 VAV-5 VAV-6 VAV-8 VAV-9 VAV-7 DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS DESV TITUS 85 170 160 335 85 130 145 220 335 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 180 180 180 180 180 180 180 180 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 FAN SCHEDULE 5. PROVIDE UNIT-MOUNT SOLID STATE FAN SPEED CONTROL. LOCATION DESIGNATION EF-5 ABOVE CEILING TYPE CENTRIFUGAL MODEL T900L CFM 760 S.P. WATTS 0.25 PHASE VOLTS/HZ EXTERNAL MOTOR IN. W.G. FAN RPM SONES DRIVE DIRECT NOTESTWIN CITY FANSERVICE EF-6 900 0.25ABOVE CEILING T1500L INLINE DOWNBLAST 810 3.7 306 120/1 60 468 120/1 DIRECT 1055 8.6 60 INLINE NOTES: 1. PROVIDE ROOF CURB. 2. PROVIDE DISCONNECT SWITCH. 3. PROVIDE BACKDRAFT DAMPER. 4. PROVIDE VIBRATION DAMPENING HANGERS. 136/137 LOCKER, 138/139 RR'S 149/150 RESTROOMS 2, 3, 4, 5 2, 3, 4, 5CENTRIFUGAL EF-7 1335 0.125ROOF 150B DCRD CENTRIFUGAL 93 120/1 DIRECT 700 5.2 60 GENERAL PRESSURE RELIEF 1, 2, 3, 5DOWNBLAST EF-8 5080 0.125ROOF 240D BCRD CENTRIFUGAL 373 120/1 BELT 550 9.7 60 ECONOMIZER PRESSURE RELIEF 1, 2, 3 NEW DUCTWORK, PIPING OR EQUIPMENT (SHOWN DARK) EXISTING DUCTWORK, PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING DUCTWORK, PIPING OR EQUIPMENT TO BE REMOVED ACCESS DOOR TURNING VANES DUCT SECTION, SUPPLY DUCT SECTION, RETURN/OUTSIDE AIR MOTORIZED DAMPER DUCT SMOKE DETECTOR AIR FLOW MEASURING SENSOR 12x12 FIRE DAMPER SMOKE DAMPER DUCT SECTION, EXHAUST 12x12 12x12 M F S C CHECK VALVE BUTTERFLY VALVE STEAM PRESSURE REGULATING VALVE STEAM DRIP TRAP ASSEMBLY TEE OFF TOP TEE OFF BOTTOM FLOW CONTROL VALVE DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW MANUAL AIR VENT (SEE DETAIL) AUTOMATIC AIR VENT (SEE DETAIL) CONCENTRIC REDUCER ECCENTRIC REDUCER ELBOW, TURNING DOWN ELBOW, TURNING UP DIFFERENTIAL PRESSURE SWITCH GLOBE VALVE ISOLATION VALVE HOSE BIBB DRAIN VALVE BALL VALVE UNION PLUG VALVE AUTOMATIC VALVE, 3-WAY, PNUEMATIC AUTOMATIC VALVE, 3-WAY, ELECTRIC/ELECTRONIC FLEXIBLE PIPE CONNECTOR AUTOMATIC VALVE, 2-WAY, PNUEMATIC AUTOMATIC VALVE, 2-WAY, ELECTRIC/ELECTRONIC RELIEF VALVE WATER PRESSURE REDUCING VALVE STRAINER PIPE GUIDE PIPE ANCHOR FLOW METER PIPE CAP CARBON DIOXIDE SENSOR (MOUNT 4'-0" A.F.F.) CARBON MONOXIDE SENSOR (MOUNT 4'-0" A.F.F.) POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT DP CO AAV MAV DUCTWORK WITH LINER VOLUME DAMPER TRANSITION, FLAT ON TOP SPLITTER DAMPER SUPPLY AIR DEVICE COUNTERBALANCED BACKDRAFT DAMPER TRANSITION, FLAT ON BOTTOM FOT FOB FLEXIBLE DUCT CONNECTION FLEXIBLE DUCT 12x12 S-1 300 CFM RETURN AIR DEVICE12x12 R-1 300 CFM EXHAUST AIR DEVICE12x12 E-1 300 CFM HUMIDITY SENSOR (MOUNT 4'-0" A.F.F.)H THERMOSTAT (MOUNT 4'-0" A.F.F.)T TEMPERATURE SENSOR (MOUNT 4'-0" A.F.F.)TS BDD HOT WATER FLOW DIAGRAM SCALE: NONE FLUE (TYP) TO NEAREST DRAIN (TYP) PRV INLET (TYP) 4" HWS PRV 4" HWR NOTE: EXISTING BOILERS AND MAIN PIPING SHALL CONTINUE TO BE USED TO SUPPLY HEATING HOT WATER TO ALL INDOOR EQUIPMENT. THERE ARE NO CHANGES TO HYDRONIC CONTROLS OR DESIGN TEMPERATURES. EXISTING BOILER2 EXISTING PUMP 3 TO BASEBOARD AND BUILDING HEATING EXISTING AIR SEPARATOR EXISTING SECONDARY LOOP TO ADDITIONAL HYDRONIC HEAT EXCHANGER EXISTING SECONDARY LOOP TO SNOWMELT HEAT EXCHANGER EXISTING SECONDARY LOOP TO SPA HEAT EXCHANGER REMOVE EXISTING SPA HYDRONIC SYSTEM. REUSE MAIN TAP LOCATION FOR NEW TERMINAL UNIT HEATING LOOP. REFER TO NEW LOOP DETAIL THIS SHEET. EXISTING BOILER1 SINGLE DUCT VAV TERMINAL BOX (TYPICAL) NEW REHEAT LOOP HOT WATER FLOW DIAGRAM SCALE: NONE NOTE: EXISTING BOILERS AND MAIN PIPING SHALL BE USED TO SUPPLY HEATING HOT WATER TO ALL NEW VAV BOXES. PROVIDE NEW PIPING AND TAP EXISTING PIPING AS INDICATED ON FLOW DIAGRAM AND ROUTE AS SHOWN ON FLOOR PLANS. NEW PUMP AND THREE WAY VALVE SHALL BE INTEGRATED INTO THE EXISTING HEATING CONTROLS SYSTEM. 1" HWS1" HWS 3/4" HWS AND HWR UNLESS OTHERWISE NOTED ON FLOOR PLANS BRANCH ISOLATION VALVES, TYPICAL AT EACH TAP FROM MAIN TO TERMINAL UNIT PROVIDE HYDRONIC BRIDGE IF NOT TIED INTO END OF RUN AS SHOWN. INDOOR AIR HANDLING UNIT SCHEDULE DESIGNATION AREA SERVED NOTESMODEL MANUFACTURER SUPPLY AIR FLOW RATE OUTDOOR AIR FLOW RATE EXTERNAL STATIC PRESSURE MOTOR SIZE FAN DRIVE SUPPLY FAN DX COOLING °F W.B.°F D.B. °F W.B. °F D.B. ENTERING AIR CONDITIONS MAX LEAVING AIR CONDITIONS EER MIN TOTAL CAPACITY MIN SENSIBLE CAPACITY ROWS HOT WATER HEATING COIL ENTERING AIR TEMP °F D.B. MIN LEAVING AIR TEMP °F D.B. MIN TOTAL CAPACITY GPM MCAVOLT/PH ELECTRICAL AHU-5 BACK OF HOUSE 3,800 RCC154/HCC154 ADDISON 915 CFM2.25" 5 HP BELT 52.9 53.2 66.1 77.0 156.1 MBH 100.5 MBH 10.7 4 55 85 211 MBH 12.6 1, 2, 3, 4, 5, 6, 7 NOTES: 1. PROVIDE MICROPROCESSOR BASED BACNET CONTROLLER. 2. PROVIDE FACTORY NON-FUSED DISCONNECT. 3. COOLING CAPACITY BASED ON 95°F AMBIENT AIR AND 8,000 FEET ELEVATION. 4. HEATING CAPACITY BASED ON 180°F HEATING WATER. 5. PROVIDE 2" MERV 8 PRE FILTER AND 2" MERV 12 AIR FILTERS AND FILTER DIFFERENTIAL PRESSURE SWITCH. 6. PROVIDE SINGLE POINT POWER CONNECTION. 7. PROVIDE CORRESPONDING OUTDOOR CONDENSING UNIT WITH SEPARATE ELECTRICAL DISCONNECT AND PRE-CHARGED LONG LINE LENGTH REFRIGERANT LINE KIT. 57.6 208 / 3 0.75xD DUCT FULL SIZE OF GRILLE RETURN GRILLE D ELBOW ABOVE CEILING CEILING 1/2" THICK ACOUSTICAL LINING D D = 12" OR 24", SEE PLAN 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:45:51 PMLEGEND, DETAILS & SCHEDULES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOTES - GENERAL MECHANICAL LEGEND - GENERAL MECHANICAL 1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 2. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 3. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS AND APPLICABLE CODES AND REGULATIONS. 4. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE ALL DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT AND PIPING DIMENSIONS PRIOR TO FABRICATION. 5. WORK SHALL BE ACCURATELY LAID OUT WITH REFERENCE TO THE ARCHITECTURAL DRAWINGS AND IN COOPERATION WITH OTHER TRADES, WHICH SHALL AFFORD MAXIMUM ACCESSIBILITY FOR OPERATION, MAINTENANCE AND HEADROOM. FAILURE TO COORDINATE WORK WITH OTHER TRADES SHALL NOT BE CONSIDERED AS A BASIS FOR EXTRA COST CHANGES. 6. DIMENSIONS SHOWN ON DRAWINGS FOR DUCTWORK ARE INSIDE CLEAR. 7. ALL DUCTWORK, INCLUDING FIRE DAMPERS, SHALL BE SEALED AND TESTED FOR LEAKS PRIOR TO COVERING WORK. 8. PATCH ALL CUTTING OR DRILLING OF FINISHED WALLS, CEILINGS AND FLOORS. 9. DIFFUSER AND GRILLE LOCATIONS TO BE COORDINATED WITH ARCHITECTURAL CEILING PLAN. ANY CEILING MOUNTED DIFFUSERS OR GRILLES WHICH DO NOT MATCH CEILING TILE SIZES ARE TO BE MOUNTED IN CENTER OF TILE. 10. CONTRACTOR SHALL INSTALL ANY BALANCING DEVICE NECESSARY TO ACHIEVE PROPER ADJUSTING AND BALANCING OF MECHANICAL SYSTEMS. 11. REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 12. LOCATIONS OF EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PENETRATIONS, ETC. ARE APPROXIMATE BASED ON SITE VISITS AND AS-BUILTS. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. ABBREVIATIONS - GENERAL MECHANICAL AAV AUTOMATIC AIR VENT AD ACCESS DOOR AFMS AIRFLOW MEASURING STATION BDD COUNTERBALANCED BACKDRAFT DAMPER BFW BOILER FEEDWATER CD CONDENSATE DRAIN CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CVD REMOTE CABLE CONTROL VOLUME DAMPER CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY DSD DUCT SMOKE DETECTOR DV HOSE BIBB DRAIN VALVE FD FIRE DAMPER FM FLOW METER FOB FLAT ON BOTTOM FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOT FLAT ON TOP GR GLYCOL RETURN GS GLYCOL SUPPLY HPS HIGH PRESSURE STEAM HRR HEAT RECOVERY RETURN HRS HEAT RECOVERY SUPPLY HWR HEATING HOT WATER RETURN HWS HEATING HOT WATER SUPPLY LPS LOW PRESSURE STEAM MAV MANUAL AIR VENT MPS MEDIUM PRESSURE STEAM PCR PUMPED CONDENSATE RETURN PRV PRESSURE REDUCING VALVE RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RV RELIEF VALVE SD SMOKE DAMPER OR SPLITTER DAMPER VD VOLUME DAMPER NOT TO SCALE6AHOT WATER FLOW DIAGRAM NOT TO SCALE4ANEW REHEAT LOOP HOT WATER FLOW DIAGRAM NOT TO SCALE4CHOT WATER COIL DETAIL SCALE: 12" = 1'-0"4B REMOTE CABLE OPERATOR DETAIL SCALE: 12" = 1'-0"3A RETURN GRILLE BOOT 1 8/25/2016 Revision 1 08/29/2016 01/11/18 ELASTOMERIC RUBBER IN SHEAR VIBRATION ISOLATORS (TYP. 4) AIR HANDLER HANGER RODS SECURED TO STRUCTURE HOT WATER PIPING TO BOILER. FLEX CONNECTION RETURN AIR 1-1/2" DEEP 18 GAUGE GALVANIZED AUXILIARY DRAIN PAN SUSPENDED BELOW UNIT. SUPPLY AIR FLEXIBLE P-TRAP CONNECTION DISCHARGE TO PLUMBING DRAIN FILTERSREFRIGERANT PIPING TO CONDENSING UNITS. HOT WATER COIL MECHANICAL DUCTWORK AND PIPE INSULATION SCHEDULE INSULATION ITEMS SYSTEM LOCATION MATERIAL THICK REMARKS -NESS DUCTWORK: DW - DUCTWRAP; FE - FLEXIBLE ELASTOMERIC SUPPLY AIR DUCT ALL INDOOR DW OR FE 2" RETURN AIR DUCT ALL INDOOR DW OR FE 2" HOT WATER SUPPLY AND RETURN PIPING ALL INDOOR FE 1-1/2" AC CONDENSATE ALL INDOOR FE 1" REFRIGERANT SUCTION AND HOT GAS PIPING AND TUBING ALL OUTDOOR FE 2" NOTES: 1. REFER TO PROJECT SPECIFICATION AND/OR SPECIFICATION NOTES ON DRAWINGS FOR PRODUCT MATERIAL INFORMATION, AND INSTALLATION REQUIREMENTS. 2. PAINT INSULATION WITH 2 COATS OF MANUFACTURER'S RECOMMENDED PROTECTIVE COATING. REFRIGERANT SUCTION AND HOT GAS PIPING AND TUBING ALL INDOOR FE 1" SEE NOTE 2 SEE NOTE 2 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:45:51 PMDETAILS AND SCHEDULES THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M002 2211 N FRONTAGE RD, VAIL, COLORADO 81657 NOT TO SCALE3AINSULATION SCHEDULE NOT TO SCALE3BAIR HANDLER HANGER DETAIL 1 8/25/2016 Revision 1 08/29/2016 01/11/18 COVERED DROP OFF EXITPASSAGE 60" FLAT SCREEN TV EQU-600 STAIR CSG-600 SCREEN ELECTRICAL ELEVATOR EQUIPMENT MASSAGE UPH-600 QTY.12 Ref.UnderCounter PUBLICRESTROOMS CHECK IN MECHANICAL POOL GM MADE FITNESS CENTER KITCHEN SPA POOL DN BALLROOM MARKET ATM POOL RESTROOM DN OFFICE EQUIP. POOL RESTROOM GUEST LAUNDRY WORK AREA BAR BOARDROOM LOBBY LUGGAGE ROOM EXIT PASSAGE RETAIL SPACE LOUNGE SKI & BOOT STORAGE 111 SKI & BOOT REMOVAL VEST. DN 1 1. SMS/SMR FROM MECHANICAL ROOM, 2-1/2". 2. SNOWMELT MANIFOLD. RE: DIAGRAM , SHEET ME2.0. 3. 2"SMS/SMR BELOW GROUND TO SNOWMELT ZONE MANIFOLDS. 4. SNOWMELT SENSOR. FLAG NOTES:# SCALE:1 SNOWMELT SYSTEM 1/16" = 1'-0" SITE PLAN 1-1/4"SMSSMR2"1-1/2" 1 S 2 22SMSSMR SMZ-1 SMZ-2 SMZ-5 SMZ-3 SMZ-4 3 3 4 2"2"1-1/2"2"1-1/4" 1-1/4" C B SNOWMELT TUBING IN PAVERS DIAGRAM NO SCALE COMPACTED GRADE UNDER-SLAB INSULATION WIRSBO TUBING WIRE MESH OR REBAR PAVERS WIRE TIE COMPACTED SOIL/SAND BED NOTES: 1. CONTRACTOR TO DIP TUBING BELOW SLAB INTO SUBSOIL AT SLAB CONSTRUCTION JOINTS. 2. PROVIDE PIPE INSULATION ON SNOWMELT TUBING PENETRATING EXPANSION JOINTS FOR 6 INCHES ON EITHER SIDE OF JOINT, OR DIP TUBING BELOW THE SLAB INTO THE SUBSOIL. 3. SECURE SNOWMELT TUBING 6 INCHES ON EITHER SIDE OF CONTROL JOINTS. 4. PRESSURE TEST SNOWMELT TUBING WITH 60 PSI OF AIR FOR 24H. TUBING TO REMAIN UNDER PRESSURE DURING CONCRETE POUR. 5. BASE MATERIAL TO BE COMPACTED PRIOR TO INSTALLING ASSEMBLY COMPONENTS.EDGE INSULATION DEPTH TO FROST LINE IF NO HORIZONTAL INSULATION IS UTILIZED IN ASSEMBLY SNOWMELT MANIFOLD PIPING DIAGRAM NO SCALE SMRSMSMANIFOLD BOX MANUFACTURER'S MANIFOLD ASSY. LOOP BALANCE/ISOLATION VALVE MANUFACTURER'S MANIFOLD ASSEMBLY WITH REVERSE RETURN PIPING. RADIANT/SNOWMELT TUBING. LOOP QUANTIITY AS REQUIRED. NOTES: 1. PROVIDE MANUFACTURER'S MANIFOLDS AND ISOLATION VALVES WITH PIPING. 2. FOR EXTERIOR MANIFOLD LOCATIONS PROVIDE WATERPROOF MANIFOLD BOX OR WATERPROOF CONTROL VALVE. TO PIPING MAINS AIR VENT AT HIGH POINTS, TYPICAL. MANIFOLD BALANCE VALVE. C SNOWMELT MANIFOLD SCHEDULE ZONE DESCRIPTION APPROX AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS MAX LOOP PRESSURE LOSS (FT) ACCESSORIES REMARKS SMZ-1 FRONT ENTRY (EXISTING)1200 12 6 6.0 - A, B SMZ-2 POOL DECK 1200 12 6 6.0 - A, B SMZ-3 POOL DECK 1400 13 7 6.0 - A, B SMZ-4 POOL DECK 1800 17 8 6.8 - A, B SMZ-5 POOL DECK 1500 13 7 6.4 - A, B MANUFACTURERS: * WIRSBO GENERAL NOTES: A: 140°F SMS TEMP; 3/4" HE PEX TUBING OR EQUAL; 300' ACTIVE LOOP LENGTH; 0.009 GPM/LF; 50% PROPYLENE GLYCOL. B: 120 BTUH/SF; 30 DEGREE DELTA T Designed: Reviewed: Project No: 9714.03 Issued: PERMIT SET 10.10.2017 \\BGCE-RSNAS\DATA\BGPROJECTS\9714.03 DOUBLETREE VAIL-EXISTIG SNOWMELT SYTEM UPGRADE & EXPANSION\DRAWINGS\9714.03M1.0.DWG10.11.172:32:01 PM Scale: As ShownDOUBLETREE - VAILSNOW MELT SYSTEM EXPANSION & UPGRADEVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ΛbgbuildingworksΛcom10.10.2017 SNOWMELT SYSTEM SITE PLAN DAL DAL M1.0 01/11/18 FITNESS CENTER SPA POOL NO SCALE GAS SERVICE ONE-LINE PIPING DIAGRAM M M M G (E) G (E)G (E)GRADE/SLAB EXISTING "HOUSE" GAS METER EXISTING PRESSURE REDUCING VALVE TYP. EXISTING GAS MAIN FROM UTILITY 2" G MANIFOLD W/SHUTOFF EXISTING 6" G TO BUILDING EXISTING "RESTAURANT 1" GAS METER EXISTING "RESTAURANT 2" GAS METER 2" EXISTING GAS TO BUILDING CONNECT TO EXISTING TAP ON GAS PIPING 1" GAS TO NEW FIRE PIT #3 (150,00 BTUH @150') 3/4" GAS TO NEW FIRE PIT #2 (150,00 BTUH @ 50') 3/4" GAS TO NEW FIRE PIT #1 (150,00 BTUH @ 50') SCALE: 1 GAS PIPING SYSTEM 1/8" =1'-0" SITE PLAN 1"G EXISTING UTILITY GAS SERVICE SEE DIAGRAM THIS SHEET NEW GAS FIRE PIT #1 NEW GAS FIRE PIT #2 NEW GAS FIRE PIT #3. SEE DIAGRAM THIS SHEET, TYPG3/4"G1"G 3/4"G GGGUNDERGROUND GAS LINE FROM MAIN. SHUT OFF VALVE IN RECESSED ACCESS. FIRE PIT CUSTOM BASE WITH VENTED ACCESS FOR RECESSED GAS CONNECTION TO FIRE PIT INSERT. MANUFACTURER FIRE PIT INSERT BY OTHERS. GAS PIPING TO FIRE PIT NO SCALE G GRADE Designed: Reviewed: Project No: 9714.03 Issued: PERMIT SET 10.10.2017 \\BGCE-RSNAS\DATA\BGPROJECTS\9714.03 DOUBLETREE VAIL-EXISTIG SNOWMELT SYTEM UPGRADE & EXPANSION\DRAWINGS\9714.03M1.1.DWG10.11.172:32:21 PM Scale: As ShownDOUBLETREE - VAILSNOW MELT SYSTEM EXPANSION & UPGRADEVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 wwwΛbgbuildingworksΛcom10.10.2017 SITE GAS PIPING PLAN DAL DAL M1.1 01/11/18 F G H J K L M N O M1 23.1 23.2 23.3 23.4 23.5 23.9 23.10 23.12 DEMOLISH EXISTING TRANSFER DUCT (NOT SHOWN, VERIFY LOCATION IN FIELD) BETWEEN 115/116 ELECTRICAL ROOM AND 114 EXIT STAIRS. SEAL ANY WALL PENETRATIONS. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/18/2017 1:18:21 PM1ST FLOOR DEMOLITION THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M101 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a6ADEMOLITION PLAN -1ST FLOOR 23.1 DISCONNECT SPLIT SYSTEMS AND TURN OVER UNITS, ACCESSORIES, AND CONTROLS TO OWNER. TYPICAL OF 3 INDOOR UNITS AND 3 OUTDOOR UNITS. 23.2 EQUIPMENT IN MECHANICAL ROOM TO REMAIN. KEEP EXISTING DUCTWORK, PIPING, AND CONTROLS IN PLACE EXCEPT WHERE OTHERWISE NOTED. 23.3 DEMOLISH THE INDICATED EXHAUST FAN (TAG EF-2, SERVING EXISTING BATHROOMS WITH 10" DIA. DUCTWORK PER THE 2003 MECHANICAL DRAWINGS). TURN OVER FAN TO OWNER. 23.4 REMOVE WALL MOUNTED ELECTRIC HEATER AND TURN OVER TO OWNER. 23.5 DEMOLISH ALL DUCTWORK FOR BOTH AIR HANDLER UNITS LOCATED ABOVE THE VESTIBULE. 23.9 DEMOLISH HEATING AND VENTILATION DUCTWORK SERVING THE FORMER HOT TUB AREA BACK TO THE INDICATED DUCT ELBOW. 23.10 DEMOLISH EXISTING EXHAUST AND RELIEF DUCTWORK SERVING THE FORMER HOT TUB AREA BACK TO THE INLET OF THE INDICATED FAN. 23.12 DEMOLISH INDICATED AIR HANDLING UNIT AND ALL ATTACHED DUCT AND PIPING. KEY NOTES NOT IN SCOPE OF DEMOLITION 1. UNLESS SPECIFICALLY NOTED, REMOVE ALL HVAC DISTRIBUTION SYSTEMS IN THEIR ENTIRETY. THIS INCLUDES BUT IS NOT LIMITED TO EQUIPMENT (WHERE INDICATED), DUCTWORK, PIPING, AIR DEVICES, AND ALL ASSOCIATED COMPONENTS AND SUPPORTS. PATCH AND REPAIR ALL AREAS THAT ARE TO REMAIN WHERE ITEMS WERE ATTACHED OR SUPPORTED. 2. COORDINATE EXTENT OF DEMOLITION WITH NEW WORK IN ALL LOCATIONS WHERE MECHANICAL COMPONENTS ARE TO REMAIN. 3. REMOVE THE TEMPERATURE CONTROLS SYSTEM COMPONENTS ASSOCATIED WITH ANY REMOVED EQUIPMENT. THIS INCLUDES BUT IS NOT LIMITED TO CONTROL PANELS, PANEL POWER FEEDS, DISTRIBUTION PANELS, CONTROL WIRING, AND ROOM THERMOSTATS. WHERE DAMPERS AND VALVES ARE TO REMAIN, THEIR RESPECTIVE ACTUATORS ARE TO REMAIN. 4. CONTRACTOR TO REMOVE ANY MECHANICAL COMPONENTS WITHIN WALLS INDICATED TO BE DEMOLISHED ON ARCHITECTURAL DEMOLITION PLANS. 5. PROTECT ALL EQUIPMENT TO REMAIN FROM DAMAGE DURING DEMOLITION. PROVIDE TEMPORARY COVERS AND CAP ENDS OF ALL PIPING AND DUCTWORK AT COMPLETION OF PARTIAL DEMOLITION. 6. COORDINATE WITH ELECTRICAL DEMOLITION BEFORE REMOVING DUCTWORK CONTAINING SMOKE DETECTORS OR EQUIPMENT, DEVICES AND SYSTEMS HAVING ELECTRICAL CONNECTIONS. GENERAL DEMOLITION NOTES 1 8/25/2016 FOR CONSTRUCTION SET 9 7/21/17 CCD-05 07/31/2017 01/11/18 J K L M N M1 23.6 23.7 23.21 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:46:00 PM2ND FLOOR DEMOLITION THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M102 2211 N FRONTAGE RD, VAIL, COLORADO 81657 23.6 DEMOLISH ALL BELOW ROOF DUCTWORK ATTACHED TO THE INDICATED ROOFTOP UNIT (TAG RTU-1 PER THE 2003 MECHANICAL DRAWINGS). 23.7 DEMOLISH ALL BELOW ROOF DUCTWORK ATTACHED TO THE INDICATED ROOFTOP UNIT (TAG RTU-2 PER THE 2003 MECHANICAL DRAWINGS). 23.21 CAP AND DISCONNECT EXISTING VENT ADJACENT TO SKYLIGHT. KEY NOTES SCALE: 1/8" = 1'-0" DRAWING REF:E401a3ADEMOLITION PLAN - 2ND FLOOR 1. UNLESS SPECIFICALLY NOTED, REMOVE ALL HVAC DISTRIBUTION SYSTEMS IN THEIR ENTIRETY. THIS INCLUDES BUT IS NOT LIMITED TO EQUIPMENT (WHERE INDICATED), DUCTWORK, PIPING, AIR DEVICES, AND ALL ASSOCIATED COMPONENTS AND SUPPORTS. PATCH AND REPAIR ALL AREAS THAT ARE TO REMAIN WHERE ITEMS WERE ATTACHED OR SUPPORTED. 2. COORDINATE EXTENT OF DEMOLITION WITH NEW WORK IN ALL LOCATIONS WHERE MECHANICAL COMPONENTS ARE TO REMAIN. 3. REMOVE THE TEMPERATURE CONTROLS SYSTEM COMPONENTS ASSOCATIED WITH ANY REMOVED EQUIPMENT. THIS INCLUDES BUT IS NOT LIMITED TO CONTROL PANELS, PANEL POWER FEEDS, DISTRIBUTION PANELS, CONTROL WIRING, AND ROOM THERMOSTATS. WHERE DAMPERS AND VALVES ARE TO REMAIN, THEIR RESPECTIVE ACTUATORS ARE TO REMAIN. 4. CONTRACTOR TO REMOVE ANY MECHANICAL COMPONENTS WITHIN WALLS INDICATED TO BE DEMOLISHED ON ARCHITECTURAL DEMOLITION PLANS. 5. PROTECT ALL EQUIPMENT TO REMAIN FROM DAMAGE DURING DEMOLITION. PROVIDE TEMPORARY COVERS AND CAP ENDS OF ALL PIPING AND DUCTWORK AT COMPLETION OF PARTIAL DEMOLITION. 6. COORDINATE WITH ELECTRICAL DEMOLITION BEFORE REMOVING DUCTWORK CONTAINING SMOKE DETECTORS OR EQUIPMENT, DEVICES AND SYSTEMS HAVING ELECTRICAL CONNECTIONS. GENERAL DEMOLITION NOTES NOT IN SCOPE OF DEMOLITION 1 8/25/2016 Revision 1 08/29/2016 01/11/18 MECHANICAL DN MECHANICAL DN SCALE: 2 EXISTING MECHANICAL ROOM PLAN - DEMO 1/4" = 1'-0" SCALE: 1 EXISTING MECHANICAL ROOM PLAN - NEW 1/4" = 1'-0" DEMO FLAG NOTES:# 1. DISCONNECT EXISTING TYPE B VENT AT THIS LOCATION. DEMO EXISTING FLUE TO EXISTING BOILERS. 2. DEMO EXISTING FLUE FOR WATER HEATERS. EXISTING WATER HEATERS TO REMAIN. 3. DEMO EXISTING BOILER AND ALL APPERTENANCES. 4. EXISTING 24" TYPE B VENT UP IN SHAFT TO ROOF TO REMAIN. 5. DEMO EXISTING SNOWMELT SYSTEM AND ALL APPERTENANCES. EXISTING SMS/SMR TO EXISTING SNOWMELT ZONES TO REMAIN. 6. VERIFY SIZE OF EXISTING HWS/HWR TO SNOWMELT SYSTEM. RE-USE IF EQUAL OR GREATER THAN 2-1/2". REMOVE AND REPLACE IF SMALLER. FLAG NOTES:# 1. NEW SNOWMELT SYSTEM. RECONNECT TO EXISTING HWS/HWR AND SMS/SMR. RE: HEATING WATER PIPING DIAGRAM, SHEET M3.0. 2. NEW BOILER ON 4" HOUSEKEEPING PAD. RE: HEATING WATER PIPING DIAGRAM, SHEET M3.0. 3. SMS/SMR TO MANIFOLD(S) 4. NEW BOILER FLUE, CAT IV, 6"Ø TO EXTERIOR. 5. NEW B-VENT FOR EXISTING CAT 1 BOILER AND WATER HEATER FLUES. CONNECT TO EXISTING FLUE. 6. LINE OF CHASE/WALL ABOVE. 7. OFFSET FLUE UP IN CHASE ABOVE AND OUT SIDEWALL PER MANUFACTURER'S REQUIREMENTS. 8. ROUTE NEW VENT FROM WATER HEATER TO NEW COMMON VENT. VENT TO BE SAME SIZE AS WATER HEATER OUTLET. 9. NEW VENT FROM EXISTING BOILER, SAME SIZE AS EQUIPMENT OUTLET. 10. BAROMETRIC DAMPER SAME SIZE AS FLUE. 11. RECONNECT NEW SMS/R TO EXISTING MAINS SERVING FRONT ENTRY SNOWMELT ZONE.(E)HWR(E)HWS(E)SMS(E)SMR(E)SMS(E)SMR1 4 2 3 5 6 2 2 2 EXISTING BOILER TO REMAIN. EXISTING WATER HEATER TO REMAIN. EXISTING DOMESTIC HOT WATER STORAGE TANKS TO REMAIN, TYP. OF 4. EXISTING WATER HEATER TO REMAIN. EXISTING SMS/SMR TO FRONT ENTRY TO REMAIN. VERIFY 1-1/4" OR LARGER..(E)HWR(E)HWS(E)SMS(E)SMR(E)SMS(E)SMRSMS SMR SMSSMR5 1 2 4 3 7 4 24" (E) 2-1/2"2-1/2"6"Ø24" (E) 22" 16" 14"1-1/4"1-1/4"6 9 10 10 8 8 11 Designed: Reviewed: Project No: 9714.03 Issued: PERMIT SET 10.10.2017 \\BGCE-RSNAS\DATA\BGPROJECTS\9714.03 DOUBLETREE VAIL-EXISTIG SNOWMELT SYTEM UPGRADE & EXPANSION\DRAWINGS\9714.03M2.0.DWG10.11.172:32:38 PM Scale: As ShownDOUBLETREE - VAILSNOW MELT SYSTEM EXPANSION & UPGRADEVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 wwwΛbgbuildingworksΛcom10.10.2017 ENLARGED MECHANICAL PLANS DAL DAL M2.0 01/11/18 T T T TT T MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 SKI & BOOT STORAGE 111 WORK AREA 108 DISHWASHING 106 BALLROOM/ MEETING ROOM 104 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119 ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101 SKI BOOT REMOVAL AREA 110 OFFICE 3 130 OFFICE 1 132 MADE MARKET 105 KITCHEN 151 LOBBY BAR 103 CHECK-IN 107 EXIT PASSAGE 112 EXIT PASSAGE 114 ELEVATOR EQUIP 113 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 MEN'S 149 WOMEN'S 150 CORRIDOR 140 PREFUNCTION 152 MEETING STORAGE 153 W EMPLOYEE LOCKER ROOM 137 23.223.11 23.11 23.11 23.11 23.11 23.11 23.11 M202 5A S-1 10" DIA. 105-24 38'-0" (TOTAL PER SIDE) 24'-0" (ACTIVE PER SIDE) PROVIDE MITERED CORNERS. LOCATE REMOTE CABLE DAMPER IN RECESSED CEILING. ENGINEERED 2-1/2" HIGH SLOT RETURN IN VERTICAL FACE OF RECESSED CEILING. SEE ARCHITECTURAL PLANS FOR DETAIL. 16 SQ. FT FREE AREA. EXISTING ROOFTOP UNIT RTU-2 TO PROVIDE: 120 MBH HEATING 7.5 TONS COOLING 2850 CFM SUPPLY AIR 750 CFM OUTSIDE AIR EXISTING ROOFTOP UNIT RTU-1 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2250 CFM SUPPLY AIR 390 CFM OUTSIDE AIR EXISTING AIR HANDLING UNIT AHU-3 TO PROVIDE: 50 MBH HEATING 1480 CFM SUPPLY AIR MIN. 400 CFM OUTSIDE AIR32x128ø10ø8ø18x12 12x12 10ø 8ø 6ø 8ø 8ø 8ø 24x16 8ø 8ø 8ø 8ø 24x14 8ø12x12 30x16 8ø 8ø8ø8ø8ø 8ø 8ø8ø 8ø 8ø10x12 6ø 6ø 6ø 6ø 6ø 6ø6ø 8ø24x8 18x12 12x12 12x12 24x1416x10 8ø 8ø 8ø 30x18 8ø S-2 230 CFM 8ø S-2 100 CFM (TYP. OF 2) 8ø S-2 190 CFM 8ø S-2 100 CFM 8ø S-2 100 CFM 8ø S-2 100 CFM 4'-0" S-1 80 CFM 4'-0" S-1 80 CFM E-1 450 CFM 8ø S-2 130 CFM 4'-0" S-1 70 CFM 4'-0" S-1 70 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 6ø S-2 90 CFM 6ø S-2 80 CFM 6ø S-2 80 CFM 6ø S-2 60 CFM 6ø S-2 60 CFM 6ø S-2 60 CFM 8ø S-2 160 CFM S-2 250 CFM S-2 250 CFM 8ø S-2 185 CFM 8ø S-2 190 CFM 8ø S-2 190 CFM 8ø S-2 190 CFM 6ø S-2 65 CFM 6ø S-2 65 CFM 8ø S-2 170 CFM 6ø S-2 65 CFM 8ø S-2 170 CFM 10x6 S-4 190 CFM 8x6 S-4 80 CFM 6ø S-2 90 CFM 6ø S-2 95 CFM 6ø S-2 95 CFM 6ø S-2 95 CFM EF-6 CU-1 CU-2 VAV-3 VAV-2 VAV-4 VAV-8 VAV-1 VAV-7 E-1 1255 CFM R-2 R-1 R-1 R-2 R-2 R-2 R-2 R-1 R-2 R-2 R-2 R-2 R-2 R-1 R-1 R-2 (TYP. OF 6) R-1 R-1 R-1 R-1 6ø8x6 S-4 150 CFM PROVIDE INTEGRAL FLUE FAN AT FIREPLACE. PROVIDE POSITIVE PRESSURE DUCT INTO ENCLOSURE AND PROVIDE FLUE GAP AT THE TOP EWH-1 SEE SHEET M202 FOR DUCTWORK ABOVE LOBBY CEILING VAV-8 VAV-3 12x10 6ø 6ø8ø 14x128ø 8ø 8ø 10ø10x12 10ø 12x6 23.13 8x612x8 6ø6ø 6ø 6ø23.156ø6ø6ø12x108x86ø 6ø6ø6ø S-2 80 CFM 8ø S-2 175 CFM 6ø S-2 40 CFM6ø VAV-4 VAV-7 VAV-5 6x6 S-4 40 CFM10x6 8x46x6 23.11 23.17 M202 5DSEE SHEET M202 FOR DUCTWORK ABOVE BATHROOM CEILINGS 20x8 30x10 22x22 36x10 16x88x6 12x108ø 8ø 18x10 10x10 8ø 6x6 8ø6ø 20x8 20x8 R-2R-2 R-2 18x1234x20R-1 R-1 R-1 R-1 COVER DUCT INLET WITH 1"x1" WIRE MESH 6ø S-2 65 CFM R-2 8ø 8ø8ø8ø8ø8ø8ø8ø 8x1023.22 T AHU-1 T RTU-1 TAHU-2 T RTU-2 T AHU-3 PROVIDE MARKEL MODEL F1FUH03003 (OR EQUAL) 3.3 KW UNIT HEATER. MOUNT UNIT AS HIGH AS POSSIBLE ON WALL. MAINTAIN MANUFACTURER REQUIRED CLEARANCE DISTANCES. DIVISION 23 TO PROVIDE ELECTRICAL DISCONNECT, ADJUSTABLE WALL BRACKET, AND BUILT IN THERMOSTAT. EWH-2 RETAIL 109 VESTIBULE 143 PROVIDE 9 MBH PACKAGED TERMINAL HEAT PUMP WITH 2.5 KW ELECTRIC HEATER. BASIS OF DESIGN IS AMANA DIGIAIRE PMH093G. BALANCE TO 30 CFM OF FRESH AIR. PROVIDE WALL SLEEVE AND INTERNAL THERMOSTAT. DISCHARGE CONDENSATE TO SPLASH BLOCK ON GRADE. M203 4A SEE SHEET M203 FOR KITCHEN LAYOUT 18x18 R-16ø 8x86ø8x610ø S-2 250 CFM 10ø 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®11/30/2017 2:55:58 PM1ST FLOOR DUCTWORK PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M201 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" =1'-0"DRAWING REF: E401a6A1STFLOOREQUIPMENTAND DUCTWORK PLAN KEY NOTES 23.2 EQUIPMENT IN MECHANICAL ROOM TO REMAIN. KEEP EXISTING DUCTWORK, PIPING, AND CONTROLS IN PLACE EXCEPT WHERE OTHERWISE NOTED. 23.11 UNDERCUT DOOR FOR 100 CFM 23.13 4" DIA. DRYER EXHAUST DUCT UP TO ROOF (TYP. OF 3). INSTALL CLOTHES DRYERS AND DRYER EXHAUST DUCT PER IMC 2012 SECTION 913 AND SECTION 504. 23.15 PROVIDE NEW 42" X 12" LOUVER. COORDINATE COLOR AND STYLE WITH ARCHITECT. MINIMUM 50% FREE AREA. 23.17 PROVIDE 12X12 IN DOOR GRILLE WITH MINIMUM 40% FREE AREA. 23.22 COORDINATE WALL HEATER LOCATION WITH ARCHITECT. 1. MAIN DUCT RUNS SHOWN TO INDICATE GENERAL ROUTING. INSTALL TIGHT TO STRUCTURE ABOVE TO ALLOW MAXIMUM CLEARANCE BELOW. COORDINATE EXACT INSTALLATION HEIGHT WITH ALL OTHER TRADES. 2. BRANCH DUCT RUNS SHALL BE AS NOTED.EACH BRANCH DUCT SHALL BE PROVIDED WITH A MANUAL BALANCING DAMPER. 3. INSTALL THERMOSTATS AT 48" A.F.F. MEASURED TO THE TOP OF THE THERMOSTAT. 4. FIRE DAMPERS SHALL BE INSTALLED IN DUCTS PENETRATING RATED WALLS IN LOCATIONS SHOWN WITH MEANS TO ACCESS THEM, BY AN ACCESS DOOR OR 12" REMOVABLE SECTION OF DUCT. 5. PROVIDE REMOTE CABLE DAMPERS FOR DUCTWORK LOCATED IN INACCESSIBLE AREAS. 6. INSTALL VAV BOXES SUCH THAT 30" CLEARANCE IS MAINTAINED FOR ACCESS TO LOW VOLTAGE CONTROL PANELS. GENERAL DUCTWORK NOTES NOT IN SCOPE OF NEW CONSTRUCTION 1 8/25/2016 FOR CONSTRUCTION SET 5 12/07/2016 RFI #55 6 1/09/2017 CCD-03 9 7/21/17 CCD-05 10 9/15/17 CCD-06 12 11/30/17 CCD-09 12/01/2017 01/11/18 TT K L M N M1 K 206 KA 204 KA 203 K 202 QQMR 205 QQ 207 KMR 208 LAUNDRY 200 CORRIDOR 240 JANITOR 200B KS 201 23.8 6ø CU-5 EF-8 EF-7 LIQUID REFRIGERANT LINE DOWN SUCTION REFRIGERANT LINE DOWN 18x4 S-3 240 CFM (TYP. OF 4) 18x4 S-3 200 CFM (TYP. OF 10) 12x612x6 10x8 10x8 16x12 16x12 336" x 4" S-3 BAR DIFFUSER WITH PREMIUM FINISH AS SELECTED BY ARCHITECT. TEN ACTIVE SECTIONS, EACH 18" LONG EXISTING AIR HANDLER AHU-2 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2000 CFM SUPPLY AIR 430 CFM OUTSIDE AIR EXISTING AIR HANDLER AHU-1 TO PROVIDE: 120 MBH HEATING 5 TONS COOLING 2010 CFM SUPPLY AIR 430 CFM OUTSIDE AIR CONNECT OA DUCT TO EXISTING INTAKES ON LOW ROOF (TYP. OF 2). CONTRACTOR TO CONFIRM EXISTING LOUVERS HAVE MINIMUM OF 0.75 SQFT OF FREE AREA. 8ø S-1 100 CFM 8ø S-1 100 CFM 4'-0" S-1 100 CFM 4'-0" S-1 100 CFM 4'-0"S-1 100 CFM 4'-0" S-1 100 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM 8ø S-2 200 CFM8ø S-2 200 CFM 8ø S-2 200 CFM R-1 785 CFM LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 VESTIBULE 101SKI BOOT REMOVAL AREA 110 8ø S-2 200 CFM 16x128ø 8ø8ø10x88ø 8ø 8ø8ø18x2024x14 24x14 12x10 12x10 6ø 6ø8x88ø 14x14 8ø 8ø 18x418x418x423.16 23.16 45 DEGREE ELBOWS 18x418x418x418x418x418x418x418x418x418x4 18x4 255" x 4" S-3 BAR DIFFUSER WITH PREMIUM FINISH AS SELECTED BY ARCHITECT. FOUR ACTIVE SECTIONS, EACH 18" LONG 18x12SEE SHEET A401d IN ARCHITECTURAL PLANS 4'-0" S-1 105 CFM 4'-0" S-1 105 CFM (TYP. OF 2) 4'-0" S-1 105 CFM 8x4 E-1 95 CFM TYP. OF 4 10x6 E-1 95 CFM TYP. OF 4 EF-5 8ø S-2 170 CFM AHU-5, DISCHARGE CONDENSATE TO FLOOR DRAIN IN MECAHNICAL ROOM 10x6 6x66x6 20x1220x8 10x8 6x66x6 6x610x6 12x106x6 6x66x10 12x8 8x10 10x10 6ø14x10 14x1010ø8ø 8ø 6x6 8ø32x12VAV-9 VAV-6 24x30 24x32 MOTORIZED DAMPERS FOR ECONOMIZER FUNCTIONALITY. SEE CONTROLS NARRATIVE. 23.14 M EMPLOYEE LOCKER ROOM 138 W EMPLOYEE LOCKER ROOM 137 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 90.00° VAV-9 VAV-6 23.19 23.18 8ø8ø8ø6x108ø6x88ø 8ø4'-0" S-1 105 CFM 8ø VAV-5 10x6 10ø 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:46:13 PM1ST FLOOR LOBBY, BATHROOM, AND 2ND FLOOR DUCTWORK PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M202 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a2A2ND FLOOR EQUIPMENT AND DUCTWORK PLAN KEYNOTESGENERAL NOTES 1. REPLACE ALL PTAC UNITS IN GUEST ROOMS (SECOND, THIRD, AND FOURTH FLOORS) WITH EQUIVALENT PTAC UNITS. THE NEW PTAC UNITS MUST SUPPLY 50 CFM OF OUTSIDE AIR. 23.8 PROVIDE NEW EXHAUST FAN TO MATCH EXISTING FANS IN GUEST ROOMS. CONNECT TO EXISTING EXHAUST DUCT IN CHASE. 23.14 CONNECT TO EXISTING LOUVER IN PRECAST WALL. CONTRACTOR TO LOCATE ACTUAL LOCATION IN FIELD. 23.16 COORDINATE DUCT INSTALLATION WITH EXISTING TRUSSES IN LOBBY AREA. 23.18 CONTRACTOR TO VERIFY 24X32" DUCT WILL FIT IN EXISTING PRECAST CONCRETE WALL OPENING. IF OPENING NEEDS TO BE ENLARGED, CONTRACTOR TO VERIFY STRUCTURAL REQUIREMENTS. 23.19 CONTRACTOR TO VERIFY THAT EXISTING LOUVER HAS MINIMUM 8.5 SQFT OF FREE AREA. OTHERWISE, COORDINATE LOUVER SIZE WITH ENGINEER. SCALE: 1/4" = 1'-0" DRAWING REF: M201 5ALOBBY DUCT LAYOUT SCALE: 1/4" = 1'-0" DRAWING REF: M2015DBACKOF HOUSE BATHROOM DUCT LAYOUT 1 8/25/2016 Revision 1 08/29/2016 01/11/18 KITCHEN AIR BALANCE OUTSIDE AIR (CFM) EXHAUST AIR (CFM) MAKEUP AIR FROM PUBLIC SPACE (CFM) BOTH HOODS ACTIVE 4100 -4900 800 30x2234x20 12ø S-5 800 CFM (TYP. OF 4) 12ø S-5 800 CFM 22x46 R-3 4000 CFM24x2024x12 24x12 24x12 24x12 24x12 24x12 20x14 3D M203 23.25 36x22 18X12 EXHAUST DUCT UP TO EF-7 ON LOW ROOF. 24X24 EXHAUST DUCT UP TO EF-8 ON LOW ROOF. 24X20 MAKEUP AIR DUCT UP TO MAU-1 ON LOW ROOF. 36X22 SUPPLY AIR DUCT UP TO RTU-A1 ON LOW ROOF. 23.26 36X34 RETURN AIR DUCT UP TO RTU-A1 ON LOW ROOF. 14x6 14x6 EXHAUST DUCT UP TO EF-9 ON LOW ROOF. T MAU-1 23.29 PROVIDE SMOKE DETECTOR IN RTU-A1 RETURN DUCT. 18x18 AIR TRANSFER DUCT 18X18 R-1 (TYP. OF 2) 12ø S-5 500 CFM 20x30 46x22 10ø 23.28 T RTU-A1 24x24 23.26 23.26 23.26 KEF-1 16ø 16ø22ø23.30 23.31 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®11/30/2017 2:56:07 PMKITCHEN DUCTWORK PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M203 2211 N FRONTAGE RD, VAIL, COLORADO 81657 10 9/15/17 CCD-06 12 11/30/17 CCD-09 SCALE: 1/2" = 1'-0"DRAWING REF:M2014A1ST FLOOR KITCHEN PLAN KEY NOTES 23.25 SUPPLY AIR CONNECTIONS TO HOOD. PROVIDE VOLUME DAMPERS IN VERTICAL DROP TO HOOD. BALANCE TO 600 CFM (TYP. OF 6). PROVIDE NONCOMBUSTIBLE INSULATION WITHIN 18 INCHES OF HOOD PER SECTION 506.3.1.2 OF THE IMC. COORDINATE EXACT HOOD CONNECTION SIZES AND LOCATIONS WITH HOOD MANUFACTURER. 23.26 21 X 10 TYPE 1 GREASE HOOD EXHAUST DUCT. COMPLY WITH ALL REQUIREMENTS IN SECTION 506 OF THE IMC. SLOPE ALL DUCT BACK TO HOOD AT A MINIMUM OF 1/4" PER FOOT. PROVIDE "ZERO CLEAR" TYPE DUCT PER DETAIL 3C ON SHEET M002. 23.28 TYPE 2 DISHWASHER EXHAUST HOOD. COORDINATE ACTUAL CONNECTION SIZE AND LOCATION WITH HOOD MANUFACTURER. 23.30 PROVIDE GREASE DUCT CLEANOUTS PER ECTION 506.3.8 AND 506.3.9 OF THE IMC. 23.31 DIRECT KEF-1 DISCHARGE AWAY FROM BUILDING. MAINTAIN MIN. 5'-0" CLEARANCE BETWEEN FAN DISCHARGE AND WALL. SCALE: 1/2" = 1'-0" DRAWING REF: M2033DKITCHEN EXHAUST DUCT SECTION 12/01/2017 01/11/18 01/11/18 T F G H J K L MEETING ROOM 127 BOARDROOM 126 POOL EQUIP 145 MECHANICAL 146 OFFICE 4 129 ELECTRICAL 116 FITNESS CENTER 148 LUGGAGE ROOM 118 ROOM 122 ROOM 121 ROOM 120 MASSAGE/ SPA WAITING 119ROOM 123 CORRIDOR 119B ROOM 124 ENGINEER 133 ENGINEER STORAGE 134 STORAGE 135 EMPLOYEE BREAK ROOM 136 RECEPTION 128 OFFICE 3 130 OFFICE 1 132 EXIT PASSAGE 114 ROOM 115 TELECOM ROOM 117 M EMPLOYEE LOCKER ROOM 138 WOMEN'S BATHROOM 139 MEN'S BATHROOM 141 GUEST LAUNDRY 147 CORRIDOR 140 W EMPLOYEE LOCKER ROOM 137 1" HWR 1" HWS1" HWS 1" HWR 1" HWS 1" HWR 3/4" HWR 3/4" HWS VAV-7 VAV-5 VAV-1 VAV-9 VAV-6 VAV-8 VAV-4 VAV-3 VAV-2 3/4" HWR3/4" HWS / FOR CONNECTION DETAIL, REFER TO: 4A M001 1" HWR 1" HWS AHU-5 LIQUID REFRIGERANT LINE SUCTION REFRIGERANT LINE LIQUID REFRIGERANT LINE FROM ROOF SUCTION REFRIGERANT LINE FROM ROOF 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:46:14 PM1ST FLOOR PIPING PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M301 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a4AHVAC EQUIPMENT AND PIPING PLAN - 1ST FLOOR SHEET GENERAL NOTES 1. PIPE TAKEOFFS FROM THE MAINS ARE THE SAME SIZE AS THE COIL CONNECTION, UNLESS OTHERWISE NOTED. 1 8/25/2016 Revision 1 08/29/2016 01/11/18 GENERAL WHEN THE UNIT IS NOT SUPPLYING AIR, THE UNIT ISOLATION DAMPERS SHALL BE CLOSED. THE SEQUENCE DESCRIBED BELOW CONSISTS OF THREE MODES: SHUTDOWN, OCCUPIED COOLING OR HEATING, AND ECONOMIZER. SHUTDOWN MODE IS INTENDED TO DESCRIBE STOPPING RTU FANS IN AN ORDERLY MANNER, CLOSING DAMPERS AND INDICATE SHUTDOWN INFORMATION AT THE CONTROLLER. OCCUPIED COOLING OR HEATING MODE IS DETERMINED BASED ON THE OCCUPANCY SCHEDULE AND ADJUSTED BY THE OPTIMAL START PROGRAM FROM THE CONTROLLER. INITIAL OCCUPANCY SCHEDULE SHALL BE RUNNING 24 HOURS PER DAY. SHUTDOWN MODE: WHEN THE RTU IS INDEXED FOR SHUTDOWN MODE, THE UNITS SUPPLY AND EXHAUST FANS SHALL STOP. THE RTU EXHAUST AIR DAMPER SHALL OPEN FULLY, RELIEF AIR, OUTSIDE AIR AND ISOLATION DAMPERS SHALL CLOSE. COOLING AND HEATING SHALL BE DISABLED DURING SHUTDOWN. THE SYSTEM SHALL BE INDEXED TO SHUTDOWN MODE IF ANY ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET: β A SHUTDOWN SIGNAL FROM THE CONTROLLER CONSOLE. β AN ALARM CONDITION FROM THE RTU SUPPLY AND EXHAUST DUCT SMOKE DETECTOR. β UPON ALARM CONDITION FROM THE RTU FREEZESTAT. OCCUPIED MODE: HEATING OR COOLING: β AT THE PREDETERMINED OPTIMUM START TIME, AS DETERMINED BY THE OCCUPANCYSCHEDULE, THE RTU WILL BE ENABLED. β THE BAS SHALL NEXT COMMAND THE RTU TO RUN AND OPEN THE ISOLATION DAMPERS. β SPACE TEMPERATURE AND HUMIDITY SETPOINTS SHALL BE LOCATED IN TWO FLOORS IN THE CORRIDORS. TEMPERATURE AND HUMIDITY SHALL BE "WORST CASE" SELECTED AS THE CRITICAL CONTROL POINT. β WITH BOTH FANS RUNNING, THE OVERALL AIRFLOWS AT CONSTANT VOLUME SHALLPROVIDE POSITIVE PRESSURE TO THE BUILDING. A BUILDING PRESSURE SENSOR SHALL BE PROVIDED AS AN AUXILIARY INPUT TO EACH UNIT. THE SENSOR SHALL MEASURE FROM AN UPPER LEVEL CORRIDOR TO OUTSIDE AMBIENT TO ENSURE A POSITIVE READING. EACH UNIT'S CONTROLLER SHALL THEN INDICATE WITH A DIGITAL INDICATION, WHETHER OR NOT THE ASSOCIATED SENSOR IS POSITIVE OR NEGATIVE. β (MECHANICAL COOLING) ON A RISE IN SPACE AIR TEMPERATURE ABOVE SETPOINT AND THE HEATING COIL IS DISABLED, COOLING SHALL BE STAGED TO MAINTAIN TEMPERATURE SETPOINT (ADJ, INITIAL SETPOINT 74 F RESET THE SPACETEMPERATURE SET POINT TO 70 F WHENEVER OAT < 35 F, BOTH ADJ.). β ON A FALL BELOW SPACE AIR TEMPERATURE SETPOINT, AND COOLING IS DISABLED,THE ELECTRIC HEATING COIL SHALL MODULATE (SCR CONTROL) TO MAINTAIN SPACE TEMPERATURE SETPOINT. β HIGH HUMIDITY DISCHARGE CONTROL SHALL BE ACCOMPLISHED VIA THE SPACE HUMIDITY SENSOR TO MAINTAIN A MAXIMUM HUMIDITY OF 55 PERCENT (ADJ.) AND ACCOMPLISHED BY COOLING AND HOT GAS REHEAT. SMOKE SHUTDOWN: IN THE EVENT THAT SMOKE IS PRESENT IN THE RTU EXHAUST OR SUPPLY AIR DUCT: β AN AUXILIARY CONTACT IN THE EXHAUST OR SUPPLY AIR DUCT SMOKE DETECTORSHALL OPEN DE-ENERGIZING THE AUTO-MAINTAINED POWER SUPPLY TO THE FAN'S STARTER OR AFD OF THE RTU CAUSING THE FANS TO SHUT OFF. β THE BAS SHALL SHUT DOWN THE EXHAUST AIR FANS UPON SHUTDOWN OF THE SUPPLY AIR FANS IN THE UNIT. β SMOKE DETECTOR CONTACTS SHALL BE WIRED IN SERIES IN THE FAN MOTOR STARTER CIRCUIT. β THE MECHANICAL CONTRACTOR SHALL PROVIDE AND TERMINATE THE HARD-WIREDCONNECTIONS FROM ANY DETECTOR RELAY (PROVIDED BY FIRE ALARM CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR) TO THE ASSOCIATED FAN TO BE SHUT DOWN, UNLESS OTHERWISE COORDINATED WITH THE UNIT MANUFACTURER. β DURING MORNING COOL DOWN THE CHW VALVE SHALL MODULATE OPEN OR CLOSED TO MAINTAIN DISCHARGE AIR TEMPERATURE AT DISCHARGE TEMPERATURE SETPOINT (ADJUSTABLE, STARTUP SETPOINT 58 F). THE AHU CONTROLLER SHALL RESET THE SUPPLY AIR TEMPERATURE SETPOINT 1 F COLDER EVERY 10 MINUTES (ADJUSTABLE) UNTIL THE SUPPLY TEMPERATURE IS AT THE OPERATING SETPOINT TEMPERATURE (ADJUSTABLE, INITIAL SETPOINT 55 F). IF THE RETURN AIR RELATIVE HUMIDITY RISES ABOVE 50%, THE 10 MINUTE CYCLE SHALL REPEAT AT THE SAME TEMPERATURE. β DURING MORNING WARM-UP THE BAS SHALL MODULATE THE PREHEAT COIL VALVE TO ACHIEVE DISCHARGE SETPOINT. AFTER THAT DISCHARGE SETPOINT IS ACHIEVED AND RETURN AIR FROM THE TERMINAL ZONES REACHES THE PREDETERMINED ROOM SETPOINT (68° F, ADJ), THE BAS SHALL COMMAND THE TWO-POSITION, MINIMUM OA DAMPER OPEN. GENERAL NOTE: 1.) TERMINAL UNIT LOOP BRANCH PUMP/LOOP SHALL BE ENABLED WHEN BOILER LOOP IS ENABLED AND RUNNING. HOT WATER PUMP: 1.) THE HOT WATER LOOP CONSISTS OF A CONSTANT VOLUME DEDICATED PUMP THAT SHALL INCORPORATE THREE-WAY MIXING VALVES AT THE TERMINAL UNIT HOT WATER COILS TO MAINTAIN FLOW AND DISCHARGE TEMPERATURE. 2.) WHEN ENABLED, THE PUMP SHALL RUN CONTINUOUSLY. 3.) THE THREE-WAY MIXING VALVES SHALL BE CONTROLLED TO MAINTAIN SPACE TEMPERATURE PER ZONE THROUGH THE TERMINAL UNIT CONTROLLER. VALVES SHALL BE SIZED TO ALLOW CONSTANT FLOW AT THE PUMP. ECONOMIZER MODE: β SYSTEM SHALL MONITOR ENTHALPY DIFFERENTIAL BETWEEN RETURN AIR AND OUTDOOR AIR. WHEN OUTDOOR ENTHALPY IS LESS THAN RETURN AIR ENTHALPY, ECONOMIZER MODE SHALL BE ENABLED. β WHEN ECONOMIZER MODE IS ENABLED, OPEN OUTDOOR AIR DAMPER TO 100% SETTING AND CLOSE THE RETURN AIR TO THE 0% SETTING. COOLING AND HEATING SHALL BE DISABLED WHEN ECONOMIZER MODE IS ENABLED. 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®8/29/2016 4:46:14 PMUNIT CONTROLS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS M701 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SEQUENCE OF OPERATIONS AHU VARIABLE AIR VOLUME AIR HANDLER UNIT SEQUENCE OF OPERATIONS TERMINAL UNIT HYDRONIC CONTROLS 1 8/25/2016 Revision 1 08/29/2016 01/11/18 ξξξξξξ ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξξξ ξξξξξ ξξξξξξ ξξξξξξξξ ξξξξξ ξξξ ξξξ ξξξ ξξξ ξξξ ξξξ ξξξξξξ ξξξ ξξξ ξξξξ ξξξξξξξ ξξξξξ ξξξξ ξξξξξξξ ξξξξξξ ξξξξ ξξ ξ ξξξξ ξξξξξξ ξξξξ ξξ ξ ξξ ξξξξ ξξξξξ ξξξξξξξ ξξ ξξξξξξξξ ξξξξ ξξξξξ ξξξξ ξξξ ξξξξ ξξξξξ ξξ ξξξ ξξξξξ ξ ξξξξξ ξξξξξξ ξξξξ ξξξ ξξξξ ξξξξ ξξξ ξξξξξξξξξ ξξ ξξξξ ξξξξξ ξξξξ ξξ ξξξξξξξξξ ξξ ξξξξξ ξξξξ ξ ξξ ξξξ ξ ξξξξξξ ξ ξ ξξ ξξ ξξξξξξξ ξ ξξξξξξ ξξ ξξξξ ξξξξ ξ ξ ξξ ξξξξξ ξ ξξ ξξξξξξξξ ξ ξξξξξξ ξξξξξ ξξξξξξξ ξ ξξξξξ ξ ξξ ξξξξξξξξ ξ ξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξξ ξ ξξξξξ ξ ξξ ξξξξξξξξ ξ ξξ ξξ ξξξξξξξ ξξξξ ξ ξξ ξξ ξξξξ ξξ ξξξξξ ξξξξ ξξξξξξξξξξξξ ξξ ξξ ξξξξξ ξξξί° ξξ ξξξ ξξξξξ ξξ ξξξξξ ξξξξξ ξ ξξξξξ ξξξξξ ξξξ!"" ξξξξ ξξξξξξ ξξξξ ξξξ ξξ ξξξξξξξξξξ ξξξξξξξξ ξξξξξξ ξξ ξξξξξξξξ ξξξξ ξξξξξ ξξξξ ξξξξξ ξξξξξξ ξξξξξξξξ ξξξ ξξξξξξ ξξξξξξξξξξξ ξξ ξ ξξξξ ξξξξξξ ξξξξξ ξξ ξξξξξ ξξξξξξξ ξ ξξξξ ξξξ ξξξξξξξξ ξί° ξξξ ξξξξξξ ξξξ ξ ξξ ξξξξξξ ξξξξξ ! ξξξ ξξξξ #ξ ξξξξξξξ ξξξξ ξξξξ ξξ ξξ ξ$% ξξξξξ ξξξξξ ξξξξξξξξ ξ ξξ ξξξ ξξξξ ξξξξξξ ξξξξξξξξί° ξξξξ ξξξξξξ ξξξ ξ ξξξξξξ ξξξξξξ ξξ ξξξξ ξξξξ ξξξξξξ ξξξ ξξξξξ ξξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξ&ξξξξξ ξ"ξ' ξξξξξξξξξξ# ξξξ ξξ ξξξξ ξξξξ ξξ ξξξξξ ξξ ξξ ξξξξ ξξ ξξξξξξξξξ ξξξξξξξ ξξξξξξξξξ ξξξξξξξ ξξξ ξξξ ξ#ξ ξ ξ ξξξξξξξξ ξξξ ξ#ξ# ξξξ $""ξ ξξξξξξξ ξξ ξξ ξ(ξξ)ξ"$"" ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ *ξ"ξξ+ξξ"ξ' (%!ξ%($ ξξξξξξξξξξξξ ξξξξξξ ξ ξξξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξί°!ξξ!ξξ " ξξξξξξξξξξξξ ξξξξξξξξξ ξξξξ ξξξξ ξ #ξξξξξξξ ξξξ ξξξξξ ξξξξξξξξ ί°ξξξ$ ξξξξξ ξ ξ ξξξξξξξ ξ ξξξξξξξξξξξξ ξ ξ ξξξξξξξ ξ ξξξ ξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξ ξξ ξξξξξξξξ ξξξξ ξξξξξ ξξξ ξξξξξ ξξξξξ ξξξ ξ ξ ξξξξξξ ξξξ ξξξξξ ξ ξξ ξξξξξξξξ ξξξ ξξξξξ ξξξ ξξξξξξξξ ξξξ ξξξξξ ξξξξξξ ξξξ ξξξ ξξξξ& ξξξξξ ξ ξξξ ξ ξξξξξ ξ ξ ξξ ξξ ξξξξξξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξξ ξ ξξξξξξξ ξξξ ξ ξξξξξξ ξξξξξξξξ ξξξξξξξξξξξ ξξξξ ξξ ξξ ξξξξξ ξξξξ ξξξξξ%ξ ξξξξ ξξξξξ ξξξξξξ ξ ξξξ ξξξί° ξ $ί° ξί° ξξξξ ξξξξξξξξξ ξξξξξξ ξ ξξξ (ξ)ί° (ξ)ί° ξ ξ ξξξ( ξξξξξξξξξ ξξξ ξ ξ ξξξ ξ ξ ξ ξξξί° ξ ξξξί° ξξξ$ ξξξξξξ ξξξ ξ ξ ξί° ξί° ξξξ! ξξξξξξ ξξξ ξξξξξξξξξξξξξξξξ ξξξί° ξξξί° ξ ξ ξξξ' ξ ξξ ξξξξ ξξξ+ ξξξξξξξ ξ ξξξ ξξξί° ξξξί° ξί° ξί° ξξξ) ξξξξξξ ξξξξξξξξ ξξξξξξ ξ ξξξ (ξ)ί° (ξ)ί° ξ ξ ξξξ, ξξξξξξ ξξξξξξξξ ξξξ ξ ξ ξξξ ξ ξ ξ ξξξί° ξ ξξξί° ξξξξ" ξξξξ ξξ ξ ξξξ (ξ$ί° ξ ξί° ξί° ξξξξξξξξ ξ ξξξξ ξξ ξ ξξξξξξξ ξξξξξξξ ξξξξξξξ ξξξξξ ξξξξξξ ξξξξξξξξ ξξξξξ ξξξξξξ ξ ξξξ ξί° ξ $ί° ξί° ξξξξξ ξξξξξξ ξξξξξξξξ ξξξξξξξ ξξξξξξ ξ ξξξ ξξξί° ξξξί° ξί° ξί° ξξξξ( ξξξξξξξξξ ξξξ ξ (ξ)ί° (ξ)ί° ξ ξξξί° ξ ξξξί° ξξξξ$ ξξξξξ ξξξξξξ (ξ)ί° ξ ξ ξξξί° ξ ξξξί° ξξξξξξξξ ξ ξξξξξ ξξξξξξ ξ ξξξξξξξ ξξξξξξξξξξ ξξξ ξξξξξξξ ξξξξξξξ ξξξξ! ξξξξξξξξξ ξξξξξξξ ξξξξξξ ξ ξξξ ξξξί° ξξξί° ξί° ξί° ξξξξξξξξ ξξξξξ ξξξξ ξξξξξ% ξ ξξξξ ξ ξ# !)!ξ+"ξ''ξξ ξξ ξξξξ ξξξξ ξξξξ -ξ ξξξ&ξ ξξξξξ ξξξξ ξξξξξξ ξ ξξξξξξξξ ξξ ξξξξξξξ ξξξ ξξξξ ξξ ξ ξξξξξξ ξξ ξξ# ξξξ ξξξξ ξξ ξ ξξξξξξξξ% ξξ ξξξ ξξξξξ ξξξξ-ξξ ξξξ ξξξξξ ξ ξξξ ξ ξξξξ ξξξξξξξ ξ ξξξ ξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξ ξ& ξξξξ ξ ξξ ξξξξξξξξ ξξξ ξξξξ ξξξξ ξξξξξξξ ξ ξξ ξξξξξ# ξξξ ξξξξξ&ξ ξξξξ-ξξ ξξξ ξξξξξ ξ ξξξξξ ξξ ξξξ ξ ξξξξ ξξξξξξξ ξξξξξ ξξξ ξξ ξξ ξξξξξ ξξξξξ ξξξ ξξξξξ ξξξξ ξ ξξ ξξξξξξξ ξ ξξ# ξ'"ξ ξ")ξ ξξ ξ ξξξ ξξξξξξξξξξξ&# ξξξ ξξξξ ξξξξξ ξξ ξξξξξ ξξ ξξξξ ξξ ξξξξξξξ ξξξξ ξξ ξ ξξ ξξξξξξξξ # ξξξ ξξξ ξξξ ξξ-ξξ ξξξξξ ξξ ξξ ξξξξξξξ ξξξξξξ ξξξ ξ ξξξξξξξξξ ξξξ ξξξ# ξξξ ξξξ ξξξξξξ ξ ξξξξξ ξξ ξξ ξξξξξξξ% '. ξ#ξ# ξξξ ξξξξξξ ξξξξ ξ ξξ$ί° ξξ ξ ξξξξξξξ $. ξ#ξ# ξξξ ξξξ ξξξξ ξξξξ ξξ ξξξξξξξξ ξ ξξξ ξξξξ ξξξξξ ξξ ξξ ξξξξξξξ ξξξξξξ ξ. ξξ ξξξξ ξξξξ ξξ ξξ ξξξξξξξξξ ξξξ ξξξξ ξξξξξ ξξ ξξξξξξξ ξξξξ ξξξξξξξ ξξ ξξξ ξ ξξ ξξ ξ ξξ ξξ ξξξξξξ ξξξξξ ξξξξ ξξ ξξξ ξξξξξξξξ # ξξξξξ ξξξξξ ξξ ξ ξξξξξ ξξξξξ ξξ ξξ ξξξ ξξξξ ξξ ξ ξξξξξξξξ ξξξξξ ξξ ξξξξ ξξ ξξξξξξξξξξ ξξξξξξξ ξξ ξξ ξξξξξ ξξξ ξξξξξξ ξ ξξ ξξξ ξξξξξξ ξ ξ ξξ ξξξξξξξ ξξξξξξ ξ ξξξ/ξξξ ξξ ξξξ ξξξξξξξξ ξξ ξξξ ξξξξξξξξξξ ξξ ξ ξξ ξξξ ξξξξ# ξξξξ ξξξξξξ ξ% ξξξξ ξξξ ξξξξξ ξξξξξξ ξξ ξ ξξξ ξ ξξξξξ ξ ξξ ξξξξξξξξ ξξ ξξξξ ξξξξξξξξξξ ξξξξ# ξξξξ ξξξ ξξξξξ ξξξξξ ξ ξξ ξξ! ξξξ ξξξξ ξ ξ ξξξξ ξξ ξξξξξξξξ ξξξ ξ ξξξξξ# ξξξξξξξ ξ ξξξξξξξξξξξξξ ξ ξξξ ξξξξ ξ ξξξξ ξ# ξξξ ξξξξ ξξξξξ ξξ ξξξ ξ ξξ ξξξξξξ ξξξξξξξξ ξξ ξξξξ ξξξ ξξξξξξξξξξ ξξ ξξ ξξξ ξξξξξ ξξξξξξξ ξξ ξξξξξξ ξξξξξξξξξ ξξ ξξ ξ ξξξξξξξ ξ ξξξξξξ ξξξξξξξξξξ ξ ξξ ξ ξξξξξ ξξ ξξξ# ξ# ξξξξ& ξξξξξξξξ ξξξξξξξ ξξξξξξξξξξ ξξ ξ ξξξξξ ξξ ξξξξξξξξ ξ ξξξξξ ξξξ ξξ&ξξ ξξξξξ ξξ ξξ ξξξξξξξξξ ξ& ξξξξξ ξξξξξ ξξ ξξ ξξξξ ξξξξξξ ξξ ξ ξξ ξξ ξξξξξξξ ξξ ξξξξ ξ ξξξ ξ ξξ ξξξξ ξξξ ξξξξξξξξ ξξξξξ ξ&ξξξξ ξξ ξξξξξξξξξ ξξξξξ ξξ ξξξ ξξξξξ ξξξξξ # (# ξξξ ξξξξξξξ ξ ξξξξξ ξ ξξξξξ ξξ ξξξξξξξ ξξξξ ξξξξ ξξξξξ ξξξξξξξξξ ξξξ ξξ ξξξξξξ ξ ξξξξξξ ξξξξ ξξξξξξξξξ ξξξξξ ξξξξξξξξξ ξξξ ξξξξξξ ξξ ξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξ ξ ξξ ξξξξξξξξξξ # $# ξξξξξξξ ξ ξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξ ξξξ ξξξξξ ξξ ξ ξξξξξ ξξξ ξξ ξξξξξ ξξ ξξξ ξξ ξξξ ξ ξξξξξξ ξξ ξξξξξξξξξξξ ξξξξξξξξ ξ# !# ξξξξξξξ ξ ξξξ ξξξξξξξ ξξξξξ ξξ ξξξξξ ξξξ ξξξξξξξξξξξ ξξ ξ ξξξξξξ ξξ ξξξξξξξξ ξξξξξ ξξξξ ξξξξξξξξξξξ ξξξξξξξξ ξ ξξ ξ ξξξξ ξξξ ξξ ξξξ ξ ξξξξξξ ξ ξξ ξξξξξξξξ ξ# '# ξξξ ξξξξξξξ ξξξξξ ξξξξξ& ξξξξ ξξξ ξξξξξ ξξξξξξξ ξξξ ξξ ξξξξξξ ξ ξξ ξξξξξξξξξξξ ξξ ξξξξξξ ξξξξ ξ ξξξξ ξξξξξ# +# ξξξξξξ ξξ ξξξ ξξξξξξξξξξξξ ξξ ξ& ξξ ξ ξξξξξξξξ ξ ξξξ ξξξ ξξξξ ξξξξξ ξξ ξξξξ# ξξξξξξξ ξ ξξξ ξξξξξξξ ξξξξξ ξξξξξ& ξξξξξξξ ξ ξξξ ξξξξξξ ξ# )# ξξξξξ ξξξξ ξξξξξ ξξ ξξ ξξξξξξξ ξξ ξξ ξξξξξξξ ξξ ξξξξξξ ξξ ξξ ξ ξξ ξξξ ξξξξξξξξξξ ξξξξξξξ ξ ξξξξ# ξ ξξ ξξ ξξξξξξξξξξ ξξ ξξξξξξ ξξξξξξξξξξ ξξξξξξ ξ ξξ ξξ ξξξξξξ ξξξξ ξξ ξξξξξξ ξ ξξ ξξξξ ξξξξξξ ξξξξξ ξξξξξξξξ ξξξξξξξξ ξξξξ ξξξ& ξξξξξξξξ #ξξξξξξξ ξξξ ξξξξξξ #ξξξξξ ξξξξξξξξ ξξξ%ξξ ξξξξξξξξ ξξξξ ξξξξξξξξ ξξξξξξξξ ξξξ ξξξξξ ξξξξξ ξ# ξξξξξξ ξξξξ"ξ ξξξξ ξξξξ ξξξξξξξξ ξξξξξξξξ ξξ/ξξξξξξξ ξ ξξξξξξξξξξ -ξ ξξξξ ξ /ξ& ξ ξξξξξ ξξξξξξ ξ"!" ξξξξ"ξ ξξξξ ξξξξ ξξξξξξξξ ξξξξξξξξ ξ ξξ ξξξ/ξξξξξξξ ξ ξξξξξξξξξξ -ξ ξξξξξξ ξξξξ ξξξ ξξξξξ /ξ& ξ ξξξξξ ξξξξξξ (ξ"" ξξξξξξξ ξ ξξξξξξξ ξξξξξξξξξξξξξ ξ ξξξξ ξξξξξ#ξξξξξξξ ξξξξ ξξξξξξ ί°ξξξξξξξξ ί° ξξξξ ξξξξξ ξξξξ ξξξξξξ ξξξξξ ξξ(!),# ξξξξ ξξξξξ ξξ ξξ ξξ ξξξξ ξξξξ ξξ ξξξξ# ξξξξξξξ ξξξξξξ ξξξξξ ξξ$+(ξξξξ" ξξξξξξξξξξ ξξξξ&ξξξξ& ξξξξξ ξξξξ ξξξξξ ξξξξ ξξξξ ξ ξξξξ ξξ ξ ξξξξξξ ξ ξ# ξξ+'(+ ξξ ξξξ ξξξξξ& ξξξξ ξξξξ# ξξξξ ξξξξξξ ί°ξξξξξξξξί° ξξξξξξξξξξ ξξξξξξξξ ξξξ ξ ξξξξξξ ξξξξξ ξξ+("'"ξ$# ξξξ( ξξξξξξ ί°ξξξξξξξί° ξξξξξξξ ξξξξξξξξ ξξξ ξ ξξξξξ ξξξ,,ξξ)# ξξξξξξξ ξξξξξξ ξξ ξ ξξξξξ& ξξ ξξξξξξξξ ξξξξξ ξξ ξξξξξξξ ί°ξξξξξξξξξ ξί°# ξξξ$ ξξξξξξ ξξξξ ξξξξξ ξξ ξξξξξξξ ξ '"ί°0("ί° ξξξξξ ξξξξξξξ ξξξ ξξξξξξξ ξξξξξξ ξξξ ξξξξ (ξξξξί°0 (ί° ξξξξξξ ξξξ# ξξξξξξ ξξξ ξξξξξ% ξξξξξ ξξξ! ξξξξξξ ξξξξ ξξ ξ ξξξξξ ξξ ξξ ί°ξξξξξξξξί° ξξξξξξ ξξξξξ ξξξξ ξξξξ ξξξξξ ξξξ ξξξ ξξξξξξ ξξξξξ ξξξξ!'ξξξ$ξξξ ξξξξξξξξ ξξξξξξ ξξξ ξξξ ξξξξ ξξξξξξ ξξξξξ ξξ("$ξξξξξ ξ ξξξξξξξξξ ξξξξξ ξξξξ ξξξξξ# ξξξξξ ξξξξξξ ξξξξ ξξ ξξ ξξξξξξ ί°ξξξξξί° ξ#! ξξξ ξξξξξξξξξ ξξξξξ ξξξξξξ ξξξξ ξξξξξ ξξξ"ξ)$ξξξ# ξξξ+ ξξξξξξξ ξξξξξ ξξ ξξξξξξ ί°ξξξξξξξξ ξξξξί° '"ί°ξ("ί°ξξ$ί° ξξξξξξξξξ ξξξξ ξξξξξξξξξ ξξξ ξξξ ξξξξξ ξ ξ# ξξ+ξ! ξξξξξ ξξξξξ ξ ξξ ξξ+ξ' ξξξξξξ ξξξξξ ξ ξξξξξ ξξξ ξ ξξ ξξξξ ξ&ξξ# ξξξξξξξ ξξξξξξ ξξξξξ ξ ξ# $ξξ)"ξ ξ+ ξξξξξ ξξξξξξ ξξξξξξ ξξξξ ξξξξξ # ξξξξ ξξξξξ ξξξξξ ξξ ί°ξξξξξί° ξξξξξ ξ ξ# ξξξ"ξ)"ξ$ξ# ξξξξξ ξξξξ ξξ ξξ ξξξξξξ ί°ξξξξξί° ξξξξ"ξ++ξ$ ξξξξ ξξξξξξ ξ ξ# ξξ("$ξξξ ξξξξξξξξξ ξξξξξξξξ ξξξξξ ξξξ ξ ξξξξξ# ξξξξξξξξξξ ξξ ξξ ξξξξξξ ί°ξξξξξί° ξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξ ξ# ξξξ"ξ)$ξξξ ξξξξ ξ ξ# ξξ+(,+ξξξ ξξξξξξ ξξξ ξξ ξ ξξξξ ξξ# ξξξ ξξξξξ ξξξξξξ ξξ ξξ ξξξξξξ ί°ξξξξξί° ξξξξξξξξξ ξξξξξ ξξξ ξξξξξξξ ξξξξξ ξ ξ# ξξξ"ξ)'ξξξ ξξξξ ξξξξξξ ξ ξ# ξξ,!ξ$ '"ί° ξξξξξ ξξξξξξ ξξξξ ξξ ξ ξ ξ# ξξ(!!ξξξ ξξξξξ& ξξξξξ# ξξξξξξξ ξξξξξξ ξξξξξξξξξξξξ ξξξξξξξξ ξξξξξ ξξξξξ ξξ+(+ξξξξ ξ ξξ ξ ξ ξ# ξξ,!("ξξξ ξξξξ ξξξξ ξξξ ξξξξξξξξ# ξξξξξξ ξξξξξ ξξ!)ξ$ξξξ ξξξξξξξξ ξξξξ ξξξξξ ξξ($,ξξξ ξξξξξξξξ ξξξξ# ξξξ) ξξξξξξ ί°ξξξξξξξξί° ξξξξξξξξξ ξξξξξξ ξξξξξ ξξξ($'(ξξξ ξξξ, ξξξξξξ ί°ξξξξξ&ξ ί° ξξξ(("ξξξ" ξξ ξξξξξξξ ξ ξξξ ξ ξξξξ" ξξξξξξ ί°ξξξξξξ ί° ξξξξξ ξξ$,,ξξξξξ" ξξξξ ξξ ξ ξξξξξξ ξξξξξξξξ ξξξξξ ξξξ(!ξ,ξξξ ξξξξξ ξξξξξξ "#! ξξξ ξξξξξ ξξξξξξ ί°ξξξξξξξξξί° ξξξξξ ξξ$("ξ ξξξξξξξξξξ ξξξ ξξξξξ ξξξξξξ ξ ξξξξξ ξξξ(!ξ+ξξξ ξξξ ξξξ ξξξξ ξξξξξξ ξ#ξ) ξξξ ξ ξξξξξ ξξ$+(ξξξ ξξξξξξ ξξξξ ξξξξξ ξξξξξξξ ξ ξξξξξ "ξξξξ'( ξξξξξξ 'ξ"' ξξξξξξξ ξξξξξξ ξξξξ# ξξξξξξ ξξξξξ ξξξξξ ξξ$!ξξ(ξξξ 1 ξξ$!ξξ,ξξξ ξξξ ξξ ξ ξξξξ ξξ# ξξξξξξ ξξξξξ ξξξξξ ξξξ$!ξξξξ$ξξξ ξξξξ ξξ ξ ξξξξξξξξ# ξξξξξξ ξξξξξξ ξξξξξ ξξ,,ξ$ξξξξ ξξξ ξξξξξξξ ξξξ# ξξξξξξ ξξξξξξξξξ ξξξξξ ξξξξ+$)ξξξξξ ξ ξξξξξξξξ ξξξξξ ξξξ ξ ξξξξξ ξξξξ( ξξξξ& ξξξξξ ξξξξξ((ξξ!! ξξξξξ ξξξξ ξξξξξ ξξξξξξ ξξξξ ξξξ ξξξξ ξξξ ξξξ ξ ξ ξξξξ& ξξξξξ ξξξξ$$ξξ ξξξξξξ ξξξξ$ ξξξξ& ξξξξξ ξ-ξξ)ξ ξξξξ! ξξξξξξξ ξ ξξξξξ "ξξξξ'( ξξξξξξ 'ξ"' ξξξξξξξ ξξξξξξ ξξξξ# ξξξξξξ ξξξξξ ξξξξξ ξξ$!ξξ(ξξξ 1 ξξ$!ξξ,ξξξ ξξξ ξξ ξ ξξξξ ξξ# ξξξξξξ ξξξξξ ξξξξξ ξξξ$!ξξξξ$ξξξ ξξξξ ξξ ξ ξξξξξξξξ# ξξξξξξ ξξξξξξ ξξξξξ ξξ,,ξ$ξξξξ ξξξ ξξξξξξξ ξξξ# ξξξξξξ ξξξξξξξξξ ξξξξξ ξξξξ+$)ξξξξξ ξ ξξξξξξξξ ξξξξξ ξξξ ξ ξξξξξ# ξξξξξξξ ξξξξξξ ξξξξξξξξξξξξ ξξξξξξξξ ξξξξξ ξξξξξ ξξ+(+ξξξξ ξ ξξ ξ ξ ξ# ξξ,!("ξξξ ξξξξ ξξξξ ξξξ ξξξξξξξξ# ξξξξξξ ξξξξξ ξξ!)ξ$ξξξ ξξξξξξξξ ξξξξ ξξξξξ ξξ($,ξξξ ξξξξξξξξ ξξξξ# ξ ξξ ξξ ξξξξξξξ ξξξ ξξξξξ ξ ξξξξξξξξ ξξξξ ξξξ ξξξξξξξξ ξξξξξξ ξ ξξ ξξ ξξξξξξξξξξξξ ξξξξξ ξξξξ"ξ ξξξξξξ ξ ξξξξ% ξξξξ ί°ξξξξξ ξξξξξ ξξξξ"ξ ξξξξξξί° ξξ ξξξξ ξξξξξ ξξξ ξξξξ"ξ ξξξξ ί°ξξξξξ ξξξξξξξξ ξξξξξξί° ξξ ξξξξξξ ξ ξ$"ξ ξξξ ξξξξ"ξ ξξξξξξξ ξ ξξξξ ξξ ξ ξξ ξξξξξξξξ ξξξξξξξξ ξξξξξξξ ξξξξ ξξξξξξξξ ξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξ ξξξ ξ ξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξ ξξξξ ξξξξ ξξ ξ ξξξξ ξξξξ ξξ ξ ξξξξξξ ξξξ ξξξξξξ ξξ ξξξξ ξξ ξ ξξξξ ξξξξξξξ("ξξξ /ξξξ ξξ ξξξξξ ξξ ξξξξ ξξξξ ξξξξξ ξξξξ ξξξξξ ξξξξξξ ξξ ξ ξξξξξ ξξξξ ξ ξξξξξξ ξ ξξξξξξ ξ ξξξξξξ ξξξξξ ξξ ξ ξξξ ξ ξξξξξ ξ ξξξξξξ ξξξξξξ ξξξ&ξξξ &ξ ξξξξξξξξ ξ ξξξξ ξ&ξξ ξξξξ ξξξξ ξ ξ''!ξ ξξξξ ξξξξξξξ ξ ξξξξξξ ξξ# /ξξξ ξ ξξξξξξξξ ξξξξξ ξξ ξξξξξ ξξ ξ ξξξξ ξξξξ ξξξξξξξξ# ξ ξξξξξξ ξξξξξξ ξξξξ ξξξ ξξξξξ ξξξξ ξξξξ ξ '!' ξξξξξ ξξ ξξξξξξξ# ξξξξξξ ξ ξξξξξ ξ ξ ξξ ξξξξξξ ξξ ξξξξξ ξξ ξ ξξξ ξξξξξξ ξ ξξ ξξξξ ξ ξ!'$ ξξξξξ ξξ ξξξξξξξ ξξ ξξξ /ξξξ ξ ξξξξξξξξ# ξξξ /ξξξ ξ ξξξξξ ξξ ξξξξ ξξξξξ ξξξ ξξξξξ ξ ξξ ξξξ ξξ ξ ξξξξξ ξξ ξξ ξξξξξξξξ ξξ ξξξξ ξξξξ ξ ξ!))# ξξξξξξξξ ξξξ ξξ ξ ξξξξ ξξξξξ ξξξξξ ξ ξ&ξξ ί°ξί° ξξξξξξξ ξξξξ ξξξξξ ξ ξξξξξξξξξ ξξξξ ξξξξξξ ξξξξξξ ξ&ξξ ξξξξξξ ξξ ξξ ξ ,!ξ! ξξξξξξξξξ ξξξξξξ# ξξ ξξξξξξ ξξξ ξξξξξξξξ ξξξξξ ξξξξξ ξ ξξξξ ξί° ξξξξξ ξξξξ ξξξξξξ ξξ ξ ξξξξξξξξξξ ξ! ξξ/ξξξξξξξ ξξξξξξξ ξξξξ&ξξξξ ξξξ& ξξξξξξξ ξξ ξξξξ ξξ ξξξξξξξξ /ξξξξξξξ ξξξξ ξξ ξξξξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ξξξξ /ξξξξξ ξξξξξ ξξξξ ξ ξξξξξξξξ ξξξξξξ ξ ξξξ ξξξξξξξξ ξξ ξξξξξξ ξξξ ξξξ ξξξ ξξ ξξξξξξξξ ξξξξξξξξξ ξξ ξξξ ξξ# ξ ξξξξξξ ξξξ ξξξξξ ξ ξξξξξ ξξξξξ ξξξ $"ξ ξξξξ ξξξξ ξξξξξξξ ξξξξ ξ!( ξξξ ξξξ ξξξξ ξξξξ ξξξξ ξ!" ξξξξ ξ ξξξξξξξξξ ξξξξξξ ξξ ξ )ξξ!ξξ"ξ' ξ2345467 ξ ( ξ"ξ"+ξξ"ξ' ξξξ 8ξ 01/11/18 CEILING CLEANOUTCO FLOOR CLEANOUTFCO WALL CLEANOUTWCO EXTERIOR CLEANOUT TEE OFF TOP TEE OFF BOTTOM CONCENTRIC REDUCER ECCENTRIC REDUCER ELBOW, TURNING DOWN ELBOW, TURNING UP GATE VALVE SCREWED OR SOLDERED GATE VALVE FLANGED BALL VALVE UNION MIXING VALVE P-TRAP PIPE CAP HOSE BIBB ECO DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW POINT OF CONNECTION, NEW TO EXISTING REMOVE TO THIS POINT NEW PIPING OR EQUIPMENT (SHOWN DARK) EXISTING PIPING OR EQUIPMENT TO REMAIN (SHOWN LIGHT) EXISTING PIPING OR EQUIPMENT TO BE REMOVED MOUNT TO INSIDE OF CHASE WALL DISTRIBUTION UNIT ROUTE 1/2" UNDER FLOOR TO FLOOR DRAINS MIFAB MODEL M2-500 TRAP PRIMER MOUNTED IN ACCESSIBLE LOCATION STRAINER DOMESTIC COLD WATER BALL VALVE REMOVE BATHTUB, TUB SPOUT, SHOWERHEAD, AND TRIM OFFSET DRAIN TO REUSE EXISTING SLAB PENETRATION 2" SAN SHOWER PAN NEW SHOWER VALVE 5 MIL (MIN.) WRAPPED PIPE PIPE TO BE 24: BELOW GRADE ISOLATING UNION PIPE SLEEVE GRADE1/2" TRAP PRIMER CONNECTION STRAINER DEEP SEAL P-TRAP FINISHED FLOOR 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/21/2017 9:46:29 AMSCHEDULES, LEGEND & DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LEGEND - PLUMBING ABBREVIATIONS - PLUMBING WCO WALL CLEANOUTCO CLEANOUT CW DOMESTIC COLD WATER FCO FLOOR CLEANOUT G NATURAL GAS PIPING HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SAN SANITARY WASTE V VENT PIPING NOT TO SCALE2ATRAP PRIMER DETAIL PLUMBING FIXTURE CONNECTION SCHEDULE DESIGNATION ITEM CW HW WASTE VENT REMARKS PF-1 WATER CLOSET - ADA 1/2" - 4" 2" PF-2 GUESTROOM FAUCET - ADA 3/8" 3/8" - - PF-3 GUESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-4 SHOWER PAN - - 2" 2" PF-5 SHOWER CONTROLS/SHOWERHEAD 1/2" 1/2" - - PF-6 NOT USED PF-7 BATHTUB - ADA 1/2" 1/2" 2" 2" PF-8 PUBLIC RESTROOM FAUCET - ADA 3/8" 3/8" - - PF-9 PUBLIC RESTROOM SINK - ADA - - 1 1/2" 1 1/2" PF-10 URINAL - ADA 3/4" - 2" 2" WALL-HUNG URINAL - PROVIDE FIXTURE CARRIER PF-11 PUBLIC RESTROOM WATER CLOSET - ADA 1" - 4" 2" PF-12 PUBLIC RESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2" PF-13 BREAKROOM SINK 3/8" 3/8" 1 1/2" 1 1/2" PF-14 WATER COOLER 3/8" - 1 1/2" 1 1/2" WALL-HUNG WATER COOLER - PROVIDE FLOOR-MOUNTED FIXTURE CARRIER PF-15 GUESTROOM ROLL-IN SHOWER - ADA 1/2" 1/2" 2" 2" DOMESTIC WATER BALL VAVLE: NIBCO NO. 585-70-66-NS, FULL PORT BRONZE BODY, STAINLESS STEEL, NIB-SEAL, INSULATED HANDLE, AND SOLDER ENDS. HANGERS AND SUPPORTS: IN GENERAL, HORIZONTAL PIPING HUNG FROM EXISTING CONSTRUCTION SHALL BE SUPPORTED BY MEANS OF PHILLIPS RED HEAD SELF DRILLING ANCHORS. GENERALLY, HORIZONTAL PIPING SHALL BE HUNG WITH CLEVIS, SPLIT RING, OR SPLIT STEEL HANGERS, GRINNEL FIGURES NOS. 260, 108, AND 212 RESPECTIVELY. HANGERS SHALL BE LARGE ENOUGH TO RECIEVE PIPE AND INSULATION. HANGER ROD SIZES SHALL BE AS CATALOG LISTED FOR A SPECIFIED HANGER. HANGER SPACING SHALL BE AS FOLLOWS: 6' O.C. FOR COPPER PIPE 1 1/4" AND SMALLER 4' O.C. FOR PVC SOIL PIPE IN ADDITION, HANGERS SHALL BE INSTALLED WITHIN 2' OF EACH CHANGE IN DIRECTION HANGERS SHALL BE LOCATED WITH RESPECT TO BEND SO AS NOT TO HAMPER EXPANSION OR CONTRACTION. OTHER FORMS AND ARRANGEMENTS OF HANGERS AND SUPPORTS SHALL BE USED TO ACCOMODATE SPECIAL OR UNUSUAL CONDITIONS OR CONDITIONS NOT COVERED HEREIN, SUBJECT TO THE APPROVAL OF THE ARCHITECTS AND ENGINEERS. PIPE TESTING: TEST ALL SOIL, WASTE, AND VENT PIPING IN ACCORDANCE WITH APPLICABLE CODE. TEST ALL WATER PIPING AT 125 PSI WITH NO LOSS IN PRESSURE FOR 2 HOURS. PLUMBING SPECIFICATIONS GENERAL NOTES 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF ALL LOCAL PLUMBING, HEALTH DEPARTMENT, AND BUILDING CODES, REGULATIONS AND ORDINANCES. 2. EVERY FIXTURE, DEVICE, APPARATUS, AND PIECE OF EQUIPMENT WHICH CONVEYS, USES, OR IS ACTIVATED BY WATER SHALL BE OF SUCH DESIGN AND BE INSTALLED IN SUCH A MANNER THAT THE DOMESTIC WATER SYSTEM IS PROTECTED AGAINST CONTAMINATION. 3. ALL PLUMBING PIPING SHALL BE COORDINATED WITH OTHER DISCIPLINES, INCLUDING MECHANICAL DUCTWORK, LIGHT FIXTURES, CONDUITS, AND STRUCTURE, PRIOR TO PIPING INSTALLATION. 4. PLUMBING CONTRACTOR SHALL FLUSH OUT ALL WATER AND WASTE LINES PRIOR TO FINAL CONNECTION TO FOODSERVICE EQUIPMENT. 5. PLUMBING CONTRACTOR SHALL INSTALL ALL ACCESSORIES AND FITTINGS PROVIDED LOOSE WITH FOODSERVICE EQUIPMENT AND MAKE FINAL CONNECTIONS TO EQUIPMENT. 6. CONTRACTOR SHALL COMPLY WITH CONTRACT DOCUMENTS, INCLUDING INCORPORATION OF LATEST BRAND STANDARDS. 7. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF WORK. PLUMBING CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 8. CLEANOUTS SHALL BE INSTALLED AS INDICATED ON DRAWINGS AND AS PER APPLICABLE PLUMBING CODE. NOT TO SCALE3ATUB TO SHOWER DEMOLITION DETAIL NOT TO SCALE4ATUB TO SHOWER NEW WORK DETAIL FLOOR RECEPTOR SCHEDULE ITEM BODY MATERIAL FLASHING AND ANCHOR FLANGE SEDIMENT BUCKET STRAINER HEAD STRAINER MATERIAL TOP SHAPE BASIS OF DESIGN FLD-01 CAST IRON REQUIRED REQUIRED ADJUSTABLE NICKEL-BRONZE ROUND JAY R SMITH SERIES 2050 FSK-01 CAST IRON REQUIRED REQUIRED NON-ADJUSTABLE NICKEL-BRONZE SQUARE WITH 1/2 GRATE JAY R SMITH SERIES 3100 PLUMBING FIXTURE SPECIFICATIONS ITEM SPECIFICATION PF-1 KOHLER "CIMARRON" ELONGATED BOWL TOILET MODEL K-3589. TRIP LEVER TO BE ON OPEN SIDE OF ROOM. PROVIDE KOHLER MODEL K-4731-C-0 COMMERCIAL HEAVY-DUTY WHITE ELONGATED OPEN FRONT SEAT AND KOHLER NO. K-7637 ANGLE SUPPLY WITH STOP. PF-2 KOHLER "COMPOSED" WIDESPREAD BATHROOM SINK FAUCET MODEL K-73060-4. PF-3 KOHLER "TRESHAM" DROP-IN BATHROOM SINK MODEL K-2991-8. PROVIDE P-TRAP AND SUPPLY INSULATION EQUAL TO TRUEBRO "LAV-GUARD 2". PF-4 SHOWER BASE SHALL BE BELSTONE 60"x30" SOLID SURFACE LOW PROFILE SHOWER PAN WITH 3-1/2"x 3" SHOWER DAM. SHOWER PAN COLOR: WHITE PF-5 SHOWER TRIM AND VALVE TO BE "CORALAIS" SHOWER VALVE TRIM WITH LEVER HANDLE KOHLER MODEL K-T15621-4-CP POLISHED CHROME FINISH WITH KOHLER MODEL K-304-KS-NA RITE-TEMP VALVE WITH STOPS. FIXED SHOWER HEAD TO BE KOHLER "FORTE" 2.5 GPM MULTI-FUNCTION SHOWER HEAD MODEL K-10284-CP. PF-7 BATHTUB SHALL BE KOHLER "VILLAGER BATH" 60"X30"X14" CAST-IRON WITH SAFEGUARD FINISH MODEL NO. K-715 (LEFT DRAIN) OR K-716 (RIGHT DRAIN) DEPENDING ON ROOM TYPE. PROVIDE GERBER MODEL NO. 41-802 17 GAUGE CHROME POP-UP BATH DRAIN. BATH SPOUT SHALL BE "FORTE" MODEL NO. K-10280-4A. VALVE TRIM TO BE KOHLER "FORTE" K-T10277-4 WITH KOHLER NO. K-304-KS RITE-TEMP PRESSURE BALANCING VALVE. SHOWERHEAD TO BE KOHLER "FORTE" MULTI-FUNCTION SHOWERHEAD NO. K-10284-CP WITH NO. K-7397-CP SHOWER ARM AND FLANGE. HANDHELD SHOWER TO BE KOHLER "FORTE" MULTI-FUNCTION HANDSHOWER MODEL NO. K-10286-CP WITH KOHLER NO. K-9514 60" METAL SHOWER HOSE AND NO. K-355-CP SUPPLY ELBOW. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR WITH MODEL K-349-CP SLIDEBAR TRIM. KOHLER MODEL K-7142-CP KOHLER CLEARFLO RETROFIT TOE TAP CONVERSION KIT. PF-8 KOHLER "SCULPTED" TOUCHLESS FAUCET MODEL K-13463-CP PF-9 KOHLER "KATHRYN" K-2330-G-0 UNDERMOUNT SINK PF-10 KOHLER "BARDON" MODEL K-4991-ET-0 URINAL - KOHLER WASHDOWN MODEL K-13519-CP FLUSH VALVE, 0.5 GPF PF-11 KOHLER "HIGHCREST" MODEL K-4302 FLOOR-MOUNTED WATER CLOSET - MODEL K-13517-CP MANUAL FUSH VALVE, 1.28 GPF - MODEL K-4731-C TOILET SEAT PF-12 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING VALVE PF-13 ELKAY MODEL LRADQ332255 STAINLESS STEEL DOUBLE BOWL TOP MOUNTED SINK - ELKAY MODEL LKD2442C FAUCET PF-14 ELKAY MODEL DZTL8C PF-15 STERLING MODEL 0C-S-63 SERIES 6206 ROLL-IN SHOWER BASE. KOHLER ALTEO MODEL K-45123-CP & K-45129-CP ARM AND FLANGE. KOHLER ALTEO MODEL K-T45112-4-CP TRIM AND DIVERTER. KOHLER AWAKEN MODEL K-99242-CP HANDSHOWER KIT. KOHLER RITE-TEMP MODEL K-11748-KS-NA PRESSURE BALANCING VALVE. PROVIDE KOHLER MASTERSHOWER DIVERTER VALVE MODEL K-737-K-NA AND NO. K-9530-CP DECK MOUNTED DIVERTER. KOHLER MODEL K-5824-CP SLIDEBAR WITH MODEL K-349-CP SLIDEBAR TRIM. NOT TO SCALE1B GAS PIPING EXTERIOR WALL PENETRATION DETAIL NOT TO SCALE3BFLOOR DRAIN FLD-01 DETAIL NOTES: -SEE "FLOOR DRAIN FLD-01 DETAIL" ON THIS SHEET FOR FLD-01 -SEE "FLOOR RECEPTOR DETAIL" ON DRAWING P402 FOR FSK-01 PLUMBING PIPE AND INSULATION SCHEDULE SERVICE PIPE MATERIAL PIPE INSULATION WASTE AND VENT PIPING (ABOVE FLOOR) HUBLESS CAST IRON (NO HUB) PIPE AND FITTINGS, COATED INSIDE AND OUT, (CISPI-301), JOINTS SHALL BE MADE WITH STAINLESS STEEL SHIELD AND CLAMP WITH NEOPRENE SEALING SLEEVE WASTE AND VENT PIPING (BELOW FLOOR) POLYVINYL CHLORIDE - PVC, TYPE DWV, ASTM D 2665, WITH MATCHING FITTINGS. JOINT SURFACES SHALL BE CLEAN AND FREE FROM MOISTURE. A PURPLE PRIMER THAT CONFORMS WITH ASTM F 656 SHALL BE APPLIED. SOLVENT CEMENT NOT PURPLE IN COLOR AND CONFORMING TO ASTM D 2564 SHALL BE APPLIED TO ALL JOINT SURFACES. THE JOINT SHALL BE MADE WHILE THE CEMENT IS WET AND SHALL BE IN ACCORDANCE WITH ASTM D 2588. DOMESTIC HOT AND COLD WATER PIPING TYPE "L" COPPER, HARD DRAWN, ASSEMBLED WITH WROUGH COPPER TYPE FIITINGS AND 95-5 LEAD-FREE SOLDER. INSULATE ALL DOMESTIC WATER PIPING WITH 1" THICK OWENS/CORNING FIBERGLASS 25 ASJ/SLL-II 2-PIECE HEAVY-DENSITY SECTIONAL PIPE INSULATION JACKETED WITH AN EMBOSSED VAPOR BARRIER LAMINATE, JACKET SHALL HAVE A PRESSURE SEALING LAP ADHESIVE TO ELIMINATE THE USE OF STAPLES, ADHESIVE, OR BANDS. NATURAL GAS PIPING BLACK STEEL SCH 40, STANDARD WEIGHT, ASTM A53 CONTINUOUS WELD WITH 150 POUND MALLEABLE FITTINGS 1 8/25/2016 FOR CONSTRUCTION SET 3 10/07/2016 ASI #1 9 7/21/17 CCD-05 07/31/2017 01/11/18 ξξξξ ξξξξ ξξξξ ξξξξ ξξξξ ξξξξ ξξ ξ ξξξξξξξ ξξ ξ ξξξξξξξ ξξξξ ξξξξ ξξξξ ξξξξ ξξξξ ξξ ξξξ ξξξξξξξ ξ ξ ξξ ξξξξξξξ ξ ξ ξξξ ξξξξξξξ ξξξξ ξξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξξξί°ξ!!ξ "ξξ ξ# ξξξξ ξξξξ ξξ ξξξ!ξ ξξ ξξ ξξξξ ξξ #ξξξξ$$ξξ ξξξξξ"ξ ξξξξξξξξ$ ξξξξξξξ ξξξξξξξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ ξξξ ξ ξξ% ξξξξ&ξξ$% ί°ξ ξξξξξ'ξξ ξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ( ξξ)ξξ)ξξξξ ξ*ξξ*ξξ ξ&ξξξ ξξξξξ ξ ξξξξξξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξί°ί°ξξξί° ξξξξξξξξξξ !ξξξ" ξξ ξξξ!ξξξξξξ ξξξξξξξξξξ # ξξξξξξ ξξξξξξ ξξξξ!ξξξξξ ί°$%ξξ%ξξ ξ ξξξξξξξξξξξξ ξξξξξξξξξ ξξί°ξ ξξξξ ξ ξξξξξξξξ ξξ" !ξξξ" ξξξξξξξξ $ξξξ& ξξξ!ξ* ξ)ξξ + ξ,'ξξ $ξξξξξξ ξξ#* ξξ ξξ-ξξξ./ #!ξξξ ' $ξ&ξ!ξξξξξ ξξξξ ξξ&ξί°ξ ξξ!!'ξ"ξξ !ξί°ξξξξξ ξξ$ ξξξξξξ ξξ ξξξξ ξξξξξ ξξξξ ξξ&ξί°ξ ξξξξξ ξ!ξξξξ ξξ$ ξξξξξξ ξξ ξξξξ ξξξξξ ξξξξ ξξ&ξί°ξ ξ!! ξ!"&ξξξξ #ξξξ"ξξξ ξξ ξξξξξξξξξ$ ξξ% ξξ% ξξξξξ% 0 ί°ξξξ ξξξξξξ ξξ ξξξξξξξξ ξ"ξ!ξξ ξξξξξξξ& ξξξξ ξξ&ξί°ξ ξξξξξξξξ #!ξξξ ξξξξξξξξξ ξξ$ ξξξξξξ ξξ ξξξξ ξξξξξξ ξξξξ ξξ&ξί°ξ ξξξ ξξξξξξ ξξ ξξξξξξ ξξξξξξ ξξ ξξ ξξ'ξξ"ξξ$ ξξ ξξξξ&&ξ$ξξξ ξξξ ξξξ!ξξξ !ξξξ"ξ ξξ$ #ξξξξ!ξξξξ ξξξξ ξξ&ξί°ξ ξξξ ξξξξξξ ξξ"ξξ$ ξξ!ξξ ξ!ξξ ξξ ξξξ #ξξξξ!ξξξ ξξξξ ξξ&ξί°ξ #!ξξξ $ξξξξ ξξ$ ξξξξξξ ξξ ξξξξ ξξξξξ ξξξξ ξξξξξξξξ ξξξ ξξξξξξ ξξ #ξξξξ!ξξξξ ξξ ξ"ξξξξξξ& #!ξξξξ ξξξξξ ξξ&ξί°ξ ξξξξξξ ξξ ξξξ ξ"ξ ξξξξ ξξ &ξξξξξξξξ! ξξξ&ξ ξξξξξξξξ ξξξ ξ"ξ ξ1"ξξ&ξξξ ξξ ξξ ξξ"ξξ$ #ξξ ξξξ ξ"ξ$ξξξ ξξξ ξ"ξξ ί°ξξξ#ξ !ξξξξξξξ ξ# ξξξξξξ ξξ ξξ ξξ&ξί°ξ$ξ $ξ&ξ!ξξξξξ ξξξξξξξξ ξ ξ)ξξ)ξξξξ ξ234.456 ξ 01/11/18 22.1 22.2 22.322.3 22.4 22.5 3" G (EXIST) 2" G (EXIST) 22.6 22.7 22.7 22.7 22.7 8" SAN (EXIST) 4" GW (EXIST) 4" SAN (EXIST) 22.8 22.28 22.37 22.38 22.38 22.39 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 2:12:01 PM1st FLOOR - DEMOLITION THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P101 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/8" = 1'-0" DRAWING REF: E401a6A1st FLOOR - DEMOLITION 22.1 REMOVE WALL-HUNG LAVATORY AND PIPING TO WORK POINT 22.2 REMOVE WATER CLOSET AND PIPING TO WORK POINT 22.3 REMOVE ALL PLUMBING FIXTURES AN ASSOCIATED CW, HW, WASTE, & VENT PIPING IN EXISTING PUBLIC RESTROOM 22.4 REMOVE EXISTING FLOOR RECEPTORS AND PIPING TO WORK POINTS 22.5 REMOVE GAS PIPING AS SHOWN. PIPING TO BE RE-ROUTED TO ACCOMMODATE NEW CEILING LAYOUT AND FIREPLACE. 22.6 REMOVE GAS PIPING ROUTED BELOW SLAB TO GAS FIREPLACE 22.7 REMOVE FLOOR DRAIN AND PIPING TO WORK POINT 22.8 EXISTING GAS PIPING TO FIREPLACES ON GUESTROOM FLOORS 22.28 REMOVE PIPING TO HOT TUB BACK TO MECHANICAL ROOM. EXISTING HOT TUB EQUIPMENT TO BE REUSED FOR NEW OUTDOOR HOT TUB. VERIFY LOCATION OF PIPING TO BE REMOVED. 22.37 REMOVE AND CAP EXISTING VENT THROUGH ROOF. NEW VENT THROUGH ROOF TO BE PROVIDED TO ACCOMMODATE NEW MECHANICAL EQUIPMENT ON LOW ROOF ABOVE. 22.38 FLOOR SINK EXISTING TO REMAIN 22.39 ABANDON EXISTING FLOOR SINK IN PLACE. CAP PIPING. DEMOLITION KEYNOTES 1 8/25/2016 FOR CONSTRUCTION SET 9 7/21/17 CCD-05 10 9/15/17 CCD-06 13 12/01/2017 CCD-09 12/01/2017 01/11/18 ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξ ξξξξξξξξξξ ξξξ ξξξξξξξξ ξξξξξ ξξξξ ξξξ ξξξξξξξ ξξξ ξξξξ ξξ ξξξξ ξξξξ ξξ ξξξξ ξξ ξξξξ ξξ ξξ ξξ ξξ ξξ ξξξξ ξ ξξξξξξξξξ ξξξ ξξξξξξ ξ ξξί° ξξξξξξ ξ ξξξ ξξξξξξ ξ ξξξ ξξξξξξξ ξξξξ ξξ! ξξξξ"ξξξξ ξξξ ξξξξ ξξξ ξξξξ ξξξ ξξξξ ξξξ ξξξξ ξξξ ξξξξξ"ξξ ξξί°ξ ξξξξ ξξξ ξξξξξξξξ ξξξ ξξξξξξξ ξξί° ξξξξξξξξξξ ξξξ ξ#ξξξξξ ξξξξ ξξξ ξξξξξξξ ξξξξ ξξ! ξξξξ ξξξ ξξξ$ξξξξ ξ%#ξξ ξξξ ξ&ξξ ξξξξξξξ ξξξ ξξ ξ ' ξξξξ ξξξξξξξ ξξξ ξξξξξξ ξξί° ξ&ξξ ξξξξξξξ ξξξ ξξξξξ ξξ#ξξξ ξξξξ ξξξξξξξξ$ξξξ (ξξξ ξξξ ξξ ξ ξξξξ ξξξξ$ξξ ξξξξ ξξξ $ξξξξξ#ξξ ξξξ ξξξξξ ξξξ ξξξξξξξξ )ξξ ξξ! ξξξξξξξξξ ξξξξξξξ ξξξξ ξξξ ξξξξ#ξξξξξξ ξξξ ξ ξξξξξξ ξξξ ξξξξξξξ ξξξξξξ ξξξ ξξ*ί° ξξ*ξξ ξξξξ ξξ ξξ $ ξξ)ξξ ξξ*ξξ ξξ ξξξξξ ξ ξξξξ ξ ξξ*ξ! ξξ*ξξ ξξ*ξί° ξξ*ξξ ξξ*ξί° ξξ$ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξ ξξ$ξξξ* #ξξ ξξ ξξξξ ξξξξ ξξ ξξξξξ ξξ ξξ ξξξξ ξξ ξξξξξ""ξξ ξξξξξ#ξ ξ&ξξξξξξ" ξξξξξξξ ξξξξξξξ*ξ ξ ξ ξξξξξξξξ ξξξ ξ*ξ* ξξ& ξξξ+ ξξξξξξξ"+ $ξ ξξξξξ)ξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ,ξξξξ!ξξξξξ ξ-ξξ-ξξ ξξξξξ ξξξξξ ξ ξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξί°ί°ξξξί° ξξξξξξξξξξ !ξξξ" ξξ ξξξ!ξξξξξξ ξξξξξξξξ#ξ $ ξξξξξξ ξξξξξξ ξξξξ!ξξξξξ ί°%&ξξ&ξξ ξ ξξξξξξξξξξξξ ξξξξ#ξξξξ ξξξξ ξξξξ ξ ξξξξξξξξ ξξ" !ξξξ" ξξξξξξξξ %ξξξ' ξξξξξ- ξξξξ . ξ/)ξξ "ξξξξξξ ξξξ-ξξξξ0ξξξ12 ξξξξξ ) ξξξ ξξξξ ξξξξ ξ ξξξξξξξ ξξ*ί° ξξξξ ξξξ "ξξξ ξξ ξ#ξ"ξξξ ξξξξξξξξξ ξξξ $ξξ$ξ ξξ"#ξξ ξξ*ξξ ξξξξ ξξξ "ξξξ ξξ ξξξ ξξξξξξξξξ $ξξ$ξ ξξ"#ξξ ξξ*ξξ ξ&ξξξξξξ ξξξξξξ ξξξξξξξξξξξ ξξ ξξξξξξ ξξ*ξ! ξξξ ξξξ ξξξξξξ ξ&ξξξξξξ ξξξξ ξξξξξξξξξξξ "ξξξξξ ξξ "ξξξξξξ ξξξξ ξξ*ξξ ξξξξ ξξξ ξξξξ ξξξξξ ξξξ"ξ* ξξ ξξξξξξξξ ξξ ξξ ξξξξξξξξ" ξξξξξ ξξξ"ξ* ξξ*ξί° ξξξ ξξξ ξξξξξξ ξξξξ %#ξξξ )ξξξξξξξ ξξξξξξξ ξξξ$ξ"ξ" ξξξξ ξξξξ ξξξξξ* ξξξξξξξ ξξξ ξξξ#ξξξξ#ξξξ/ξ ξξξξξ#ξξξξξξ* ξξ*ξξ ξξξξξξ ξξξ ξξξξ #ξ ξξ ξξ/)ξξξ ξ*ξ*ξ ξξξ$ξ ξξξ ξξξξξξξ ξξ*ξί° ξ#ξ ξξξ ξξξ ξ#ξ ξξξξξξ ξξξξ ξ&ξξξξξξ ξ%#ξξξξξξ ξξ ξξξ ξ#ξ"ξξξ ξξξ ξ#ξ* ξ ξξξξξξξξξ ξ3451567 ξ 01/11/18 01/11/18 ξξξξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξξ ξξ ξξξ ξξ ξξξξ ξξ ξξξξ ξξ ξξξ ξξ ξξξξξξ ξξξ ξξ ξξξξξξ ξξξ ξξ ξξξξξξ ξξξ ξξ ξξξξ ξξξξξξ ξξξ ξξ ξξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξξξξξξξξ ξξξ ξξ ξξξξ ξξξξ ξξ ξξξξξ ξξ ξξ ξξξξ ξξ ξξξξξί°ί°ξξ ξξξξξξξ ξ!ξξξξξξί° ξξξξξξξ ξξξξξξξξ ξ ξ ξ ξξξξξξξξ ξξξ ξξ ξξ ξξ! ξξξξ ξξξξ"ξξί°ξ ξξ ξξξξ#ξξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ $ξξ%ξ&%ξξξξ ξ'ξξ'ξξ ξ"ξξξ ξξξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξί° ξξ ξξξξξξξξξξ ξξξξξξξξ!ξ " ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξ#$ξξ$ξξ % ξξξξξξξξξξξξ ξξξξ!ξξξξ ξξξξ ξξξξ ξ ξξξξξξξξ ξξί° ξξξξί° ξξξξξξξξ #ξξξ& ξξξξξ' ξ%#( ) ξ*ξξ( ί°ξξξξξξ ξξξ' ξξξξ+ξξξ,- ξξξξξ ξ ί°ξ"ξξξξξξξ ξξξξξ' ξ%#( ) ξ*ξξ(ί°ξξξξξξ ξξξ'ξξξξ+ξξξ,- ξξξξξ ξ ξξξ ξξξξ ξξξξ ξξξξξξξξ ξξξ ξξ ί°ξξξξξξξξξ ξξξξξξ ξξί° ξξ"ξξξ ξξξξξξξξ ξξί° ξξξξξξξ ξ!ξξξξξξ ξξξ ξξξ ξξί° ξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξξί° ξξξ ξξξ ξξξξξξξξ ξξί° ξξξξξξξ ξξξ ξξ ξξ"ξξξ ξξξξξξξξ ξξξξ ξξξξξξ ξξξξξξξξξί°ξ ξξξ"ξ ξξί° ξξξξξξ ξ!ξξξξξξ ξξξξξξ ξξ ξξ ξξξξξξξί°ξ ξξξ ί°ξξξξξ ξξ ί°ξξξξξξ ξξξξ ξξξ ξξ ξξξξξξξ ξξξ ξξξξξξξξ ξξί° ξξξξξξξ ξξξ ξξξξ ξ!ξξξξξξ ξξξ ξξξ . ξξξξξ ξξξξξξξξξξ ξξξ ξξ ξξ"ξξξ ξ!ξξξξξξ ξξξξξξξ ξξξξξξξ ξξξξξξξξξ ξξξ"ξ ξξί° ξξξξξξξξξί°ξ ξ!ξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξξί° ξξξ ξξξ ξξξξξξξ ξξξξξξξ ξξξ ξξ ξξ"ξξξ ξ!ξξξξξξ ξξξξξ ξξξξξξξ ξ!ξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξξί° ξξξ ξξξ ξξξξξ ξξξξξξξ ξξξ ξξ ξξξξξξξ ξξξ ξξξξξξξ ξξξξξξ ξξξξξ ξ!ξξξξξξ ξξξξξξξξξ ξξξ ξξ ξξξξξξξ ξξξ ξξξξξ ξξξξξξ ξξξξξ ξ!ξξξξξξ ξξξξξξξξξ ξ #%ξξ%ξξξξ ξ/01213, ξ 01/11/18 01/11/18 ξξξξξ ξξξξξξ ξξ ξξξξξ ξξξξξ ξξξξ ξξ ξξξξξ ξξ ξξξξ ξξξξξ ξξ ξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξξξξξξξξ ξξξ ξξ ξξξξ ξξξξ ξί° ξξξξξ ξξ ξί° ξξξξ ξξ ξ ξξξξξξξί° ξξξξξξξ ξ!ξξξξξξξ ξξξξξξί° ξξί°ξξί°ξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ ξξ! ξξξξ ξξξξ"ξί°ξξ ξξ ξξξξ#ξξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ $ξξ%ξ&%ξξξξ ξ'ξξ'ξ& ξ"ξξξ ξξξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξί° ξξ ξξξξξξξξξξ ξξξξξξξξ!ξ " ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξ#$ξξ$ξξ % ξξξξξξξξξξξξ ξξξξ!ξξξξ ξξξξ ξξξξ ξ ξξξξξξξξ ξξί° ξξξξί° ξξξξξξξξ #ξξξ& ξξξξξ' ξ%#( ) ξ*ξξ(ξξξ+, ξ ξξξξ ξ ξξ"ξξξξξξί° ξξξξξ' ξ%#( ) ξ*ξξ(ξξξ+, ξ ξξξξ ξί°ξξ ξξξξ ξξξί° ξξξί°ξξξξ ξξξξξ ξξξξξί°ί°ξξξ ξξξξί°ξ ξί°ξ ξξ"ξξξ ξξξξξξξξ ξί°ξ ξ ξξξξξξ ξ!ξξξξί°ξ ξξξ ξξξ ξί°ξ ξξξξξ ξξξξξξξί°ξ ξξ ξξ ξξξξξξ ξ ξξ ί°ξξ ξξξξξξξξ ξί°ξ ξ ξξξξξξ ξξξξξ ξξ"ξξξ ξξξξξξξξ ξξξξ ξξξξξξ ξξξξξξξξξξξ ξξξ"ξ ξί°ξ ξξξξξξ ξ!ξξξξί°ξ ξξξξί°ξ ξξ ξξ ξξξξξξξξξ ξξξ ξξξξξξ ξί° ξξξξξί°ξ ξξξξ ξξξξξ ξί°ξξξξξ ί°ξξ ξξξξξξξξ ξί°ξ ξ ξξξξξξ ξξξ ξί°ξξ ξ!ξξξξί°ξ ξξξ ξξξ - ξξξξξ ξξξξξξξί°ξξ ξ #%ξξ%ξξξξ ξ./01023 ξ 01/11/18 01/11/18 ξξξξ ξξξ ξξξ ξξξ ξξξ ξξξ ξ ξξξξξξξ ξξξξξξ ξ ξξξ ξξξξξ ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξ ξξ ξξξξ ξξ ξξξξξ ξξξξξ ξξξξ ξξ ξξξξ ξξ ξξξξξ ξξξξξ ξξξξξ ξξ ξξξξ ξξ ξξξξ ξξξξξ ξξ ξξξξ ξξ ξξξξ ξξξξξ ξξξ ξξ ξξξξ ξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξξξξξξξξ ί°ξξ ξξ ξξξξ ξξξξ ξξ ξξξξξ ξξ ξξ ξξξξ ξξ ξ ξξξξξξξξ ξξξξξί°ξ ξ!ξξξξξξξ ξξξξξξξ ξξξξξξξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ ξξ! ξξξξ ξξξξ"ξξξξ ξξ ξξξξ#ξξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ $ξξ%ξ&%ξξξξ ξ'ξξ'ξ( ξ"ξ ξξ ξξξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξί° ξξ ξξξξξξξξξξ ξξξξξξξξ!ξ " ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξ#$ξξ$ξξ % ξξξξξξξξξξξξ ξξξξ!ξξξξ ξξξξ ξξξξ ξ ξξξξξξξξ ξξί° ξξξξί° ξξξξξξξξ #ξξξ& ξξξξξ' ξ%#) * ξ+ξξ)ξξξξξξξ ξξξ ' ξξξξξξξ,- ξ ξξξξ ξ ξξ"ξξξξξξξ ξξξξξ' ξ%#) * ξ+ξξ)ξξξξξξξ ξξξ 'ξξξξξξξ,- ξ ξξξξ ξ ξξξ ξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξ ξξξ ξξ"ξξξ ξξξξξξξξ ξξξ ξ ξί°ξξξξ ξ!ξξξξξξ ξξξ ξξξ ξξξ ξξξξξ ξξί°ξξξξξξ ξξ ξξ ξξί°ξξξ ξ ξξ ξξξ ξξξξξξξξ ξξξ ξ ξί°ξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξ ξξξ ξξ"ξξξ ξξξξξξξξ ξξξ ξ ξί°ξξξξ ξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξ"ξξξ ξξξξξί°ξξ ξξξξ ξξξί°ξξ ξξξξξξξξξξξ ξξξ"ξ ξξξ ξξξξξξ ξ!ξξξξξξ ξξξξξξ ξξ ξξ ξξξξξξξξξ ξξξ ξξξξξξ ξξ ξξξξξξξ ξξξξ ξξξξξ ξξξξξξξ ξξξ ξξξξξξξξ ξξξ ξ ξί°ξξξξ ξξξ ξξξξ ξ!ξξξξξξ ξξξ ξξξ . ξξξξξ ξξί°ξξξξξξξ ξξξξ ξξξξξξξξξξξξξξξ ξξξξξ ξξ ξξξ ξ ξ!ξί°ξξξ ξξξξξ ξξξξξξξξ ξξξξξ ξξξξ ξξξ ξξξξξ ξί°ξξξξ ξξξξξξ ξξξξξξξξ ξξξ ξξξξ ξξξί°ξξξξξξξξ ξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξ ξί°ξξξξ ξξξξξ ξξξ ξξξξξξ ξξξί°ξξξξξξ ξξξξξξξξξ ξ/ί°ξξ ξξ ξξί°ξξξξ )ξξξξξί°ξξξξξ)ξ ξ #%ξξ%ξξξξ ξ0123245 ξ 01/11/18 01/11/18 ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξξξ ξξξξξξξξξξξ ξξξ ξξ ξξξξ ξξξξ ξξ ξξξξξ ξξ ξξ ξξξξ ξξ ξξξξξξξξξ ξξξξξξξ ξξξξξξξξξ ξξξξξξξ ξξξξξξξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ ξξξ ξξξξ ξξξξί°ξξξξ ξξ ξ!ξξ"#ξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ $ ξξ%ξ&%ξξξξ !'ξξ'ξ" ξί° ξξξ ξξξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξί° ξξ ξξξξξξξξξξ ξξξξξξξξ!ξ " ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξ#$ξξ$ξξ % ξξξξξξξξξξξξ ξξξξ!ξξξξ ξξξξ ξξξξ ξ ξξξξξξξξ ξξί° ξξξξί° ξξξξξξξξ #ξξξ& ξξξξξ' ξ%"( ) ξ*#ξ( ξξξξξξξ ξξξ' ξξ!!ξξξ+, ξξξξξ ξξξξ # ξξ ί°ξξξξξξξ ξξξξξ' ξ%"( ) ξ*#ξ( ξξξξξξξ ξξξ' ξξ!!ξξξ+, ξξξξξ ξξξξ # ξξξ ξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξ ξξξ ξξί°ξξξ ξξξξξξξξ ξξξ ξξξξξξξ ξξξξξξξξ ξξξ ξξξ ξξξ ξξξξξ ξξξξξ#ξξξ ξξ ξξ ξξξξξξ ξξξ ξξξ ξξξξξξξξ ξξξ ξξξξξξξ ξξξξξ ξξί°ξξξ ξξξξξξξξ ξξξξ ξξξξξξ ξξξξξξξξξξξ ξξξί°ξ ξξξ ξξξξξξ ξξξξξξξξ ξξξξξξ ξξ ξξ ξξξξξξξξξ ξξξ ξξξξξξ ξξ ξξξξξξξ ξξξξ ξξξξξ ξξξξξξξ ξξξ ξξξξξξξξ ξξξ ξξξξξξξ ξξξ ξξξξ ξξξξξξξξ ξξξ ξξξ - ξξξξξ ξξξξξ#ξξξξ ξξξξ ξξξξξξξξξξξξξξξ ξξξξξ ξξ ξξξ ξξξξξξξξ ξξξξξ ξξξξξξξξ ξξξξξ ξξξξ ξξξ ξξξξξ ξξξξξξ ξξξξξξ ξ#ξξξξξξ ξξξ ξξξξ ξξξξξξξξξξξξ ξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξ ξξξξξξ ξξξξξ ξξξ ξ#ξξξξ ξξξξξξξξξξ ξξξξξξξξξ ξ.ξξξ ξξ ξξξξξξξ (ξξξ#ξξξξξ#ξ(ξ ξξ#ξξξ ξξ#ξξξ ξξ#ξξ! ξξ#ξξ! ξξ#ξξ! ξξ#ξξξ 01/11/18 01/11/18 ξξ ξξ ξ ξξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξ ξξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξ ξξξξ ξξξ ξξξξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξξξξ ξξ ξξξξξ ξξξ ξξ ξξ ξ ξξξξξ ξξξξξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξξξξξ ξξ ξξ ξξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξξ ξ!ξξξξξ ξξξξξξ ξξξ ξξξξ" ξξξξξ ξξ ξξ ξ ξξ ξξ ξ ξξ ξ ξξ ξξ ξ ξξ ξξ ξ ξξξξξ ξ ξ#ξξξξξξ ξξξ$ξξ ξξξ# ξξξ # ξ#ξξξξξξ ξξξ$ξξ ξξξ# ξξξ ξξ#ξξ%ξ &ξ ξί°ξξξ# ξξξ #ξξ%ξ &ξ ξί°ξξξ# ξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξ ξξξξξξ ξξξξξξξξξξ ξξξ ξξξξ ξξ ξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξξξξξξξ ξξξξξξ ξξ ξξ ξ ξξ ξξ ξ ξ ξξξξ ξξ ξξ ί°ξ ξξξξ ξξξξξξ ξξ ξξξξ ί°ξ ξξξξ ί°ξ ξ ξξξξ ξξ ξ ξξξξ ξξ ξξ ξξ ξ ξξξξ ξξ ξξ ξξ ξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξ ί°ξ ξξξξ ξξ ξξξξ ί°ξ ξί°ξ ξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξ ξ ξξ ί°ξ ξξ ξξ ξξξξ ί°ξ ξξ ί°ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξ ξξ ξξ ξξξ ξξξξ ξξ ξξ ξξ ξξξξ ξξ ξξξξξ ξξξξ ξξξξξξξ ξξξξξ ξί°ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξ ί°ξ ξξξξ ί°ξ ξξξξ ί°ξ ξξξξ ί°ξ ξξξξ ξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξ ξξξξ ξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξ ί°ξ ξξξξ ξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξ!ξί°ξ ξξξ" &ξ ξ$ξξξ!ξξξ ξξξ ξξ ξί°!ξ ξξξ$ !ξ ξί°ξξξ ξξ !ξ ξξ ξξ !ξ ξξξ&!ξξξξ ξ!ξί°ξξξ ξ'ξξξξξξξ ξξ!ξξξξ ξξξξξξξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ &ξ' ξξξξ ξ!ξί°#ξξξξ ξξ ξξξξξξξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ( ξξξξξξξξξ" ξ)*ξ)ξ* ξ#ξξξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξί°!ξξ!ξξ " ξξξξξξξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξ ξ #ξξξξξξξ ξξξ ξξξξξ ξξξξξξξξ ί°ξξξ$ ξξξ ξξ)ξξξξ + ξ%ξξξξξξ ξ!ξξ ξξξ) ξξξξ ξξξξξξ ξξξξ ξξ&ξ!ξ ξξξξξξξ# ξξξ ξ ξ ξξ ξξξ ξ ξξ ξξξξ ξξξ ξξ)ξξξξ + ξ%ξξξξξξ ξ!ξξ ξξξ)ξξξξξξξξξξ ξξξξ ξξ&ξ!ξ ξξ ξξξξξ ξξξ ξ ξξξ ξξ)ξξξξ + ξ%ξξξξξξ ξ!ξξ ξξξ) ξξξξ ξξξξξξ ξξξξ ξ#ξξξξξξ ξξξξξξξ# ξ ξξ ξξξ$ξξ ξξξ# ξξξ ξ ξ ξξ ξξξ ξ ξξ ξξξξ ξξξ ξξ)ξξξξ + ξ%ξξξξξξ ξ!ξξ ξξξ) ξξξξξ ξξξξξ ξξξξ ξξ&ξ!ξ ξξξξξξξ# ξξξ ξ ξ ξξ#ξξξ!ξ ξξξ ξξ)ξξξξ + ξ%ξξξξξξ ξ!ξξ ξξξ) ξξξξξξξξξξ ξξξξ ξ#ξξξξξξ ξξξξξξξ# ξ ξξ ξξξ$ξξ ξξξ# ξξξ ξ ξ ξξ#ξξξ!ξ ξξ ξξξ ξξξ ξ $ξξξξξξξ ξξξξξ ξξξξ ξξ ξξξξ ξξ ξξξ ξ ξξ!#ξξξ ξξξ ξξξ ξ ξξ!#ξξ ξξξξ !ξ ξξ ξξξ ξ!ξξ ξξξ ξξξξξ ξξξξξ ξξ ξξξξ ξξξ ξ!ξ !ξξξ ξ'!ξξ!ξξ ξξξξ ξξξ ξ$ ξ!ξί°!ξ ξξξ#&!ξξ ξί°ξ ξξ ξ ξ ξξξ ξξξξξξ ξξξξξ !ξξξξ ξξ ξξ ξί°ξξ &ξ' ξ!ξί° ξξ ξξξ ί°ξ ##ξξ ξ ξξξξξξξξ ξ,ξξ ξ ξξ !ξξ ξξξξξ ξξξ ξξξξξ!ξξξ #ξξξξ ξξξ ξξξξξ ί°ξ ξ ξξξξξ ξξξ ξξξ ξ!ξξ ξξξξ ξξξ ξξξξ!ξξξ ξ!ξξ ξξξξξ ξξξξ ξξξ ξ ξξ!#ξξ ξ!ξξ ξξ ξξξξξξξ ξξ ξ!ξξ!ξξξ ξξ &ξ !ξξξξ ξξξξ &ξξξξ ξξξ &ξ ξξξξ" ξξξξ ξξ ξξξξ ξξ ί°ξξξξ ξ!ξξ ξξξ ξ!ξξ !ξ ξ!ξξξξξ ξξξξξξ ξξξξξ ξξ ξξξξ ξ!ξξ ξξξ !ξ ξξξ ί°ξξξξ ξ!ξξ ξξξ ξ!ξξ ξξξξξξ ξ ξξξξξ ξξ ξ ξξ ξ!'ξξξξξ &ξ!ξξ ξξξξξ ξξξ ξί°ξ ξξ ί°ξ ξξ ξξξ ξξ ξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξ ξ ξξ ξξ ξξ ξξξξξξί°ξξξξξ ξξ ξ ξξ ξξ ξξ ξξξ!ξξ ξί°ξ ξξ ί°ξ ξξ ξξξξξξ ξξξξξ ξ ξξ ξξξξξ ξ !ξξξξξ ξ!ξξ !ξξξξ ξξξξ ξ,ξξ ξ ξξ ξξξξ&ξξ ξξξ ξξξξξ ξξξξξξ ξ ξξξ*ξξξξ" ξ-./0/12 ξ 01/11/18 01/11/18 ξξξξξ ξξξξξ ξξξξξ ξ ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξ ξ ξξξξξ ξξξξξ ξξξξξ ξξ ξξξ ξξ ξ ξξ ξ ξξ ξξξ ξξξξξξ ξξ ξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξ ξξξξξξ ξξξξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξξξ ξξξξξξ ξξξ ξξ ξξξξξξ ξξξ ξξξξξ ξξί°ξξξ ξξξξ ξξξξξξξξξξξξ !ξξξ ξξξ ξξξξξ ξξξ ξξξ "ξξξί°ξξξξξξ ξξξ ξξ ξξξ ξ#$ξ "ξξ ξξ ξ#ξξ "ξξ ξξ ξξ ξ ξ ξξ ξξ ξξ%ξξ ξξ%ξξ ξξ%ξξ ξξ ξξ ξ#ξξ ξξ ξ#ξξ ξξ ξ#ξξ ξξ ξξ ξ ξ ξ#ξξ ξξ ξ#ξξ ξ ξ ξ#ξξ ξ ξ ξ#ξξ ξ ξ ξξ ξξ ξ $ ξ ξ ξξ ξξ ξξξξ ξξξξξξ ξξξ ξξ ξξξξξξ ξξξ ξξξξξ ξξί°ξξξ ξξξξ ξξξξξξξξξξξξ !ξξξ ξξξ ξξξξξ ξξξ ξξξ "ξξξί°ξξξξξξ ξξξ ξξ ξ#ξξ ξξ ξξξξξξξξ ξξξξξ "ξ"ξξξ ξξξξξί°ξ ξ& "ξ"ξ ξξξξξξξξ ξξξ ξξ" ξξξξξξξξξ ξξξξξ ξ#ξ ξξξξξ ξξξ" ξξξξ ξξξ" ξξξξξξξξξ ξξξξξ ξξξξ ξξξξξξ ξξξξξξξξ ξξξξξξξξξ ξξξξξ ξξξξξξξξ ξξξξξ "ξ"ξ ξί°""ξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξ"ξξξξξ ξ ξξξξ ξξξξξξξξξξ% ί°ξξ ξξ ξξ ξξ ξξξξ ξξ ξξ ξξξ ξξ ξξ "ξξξ ξξ ξξξξξξξξξ ξξξξ ξί°ξ ξ&"ξξξξξξ ξξξξξξξ ξξξξξξξ%ξ ξ ξ ξξξξξξξξ ξξξ "%ξ% ξξ& ξξξ' ξξξξ ξξξξ' ξξ ξξξξ$ξξξξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ( ξξ#ξ)#ξξξξ ξ*ξξ*ξ+ "ξξξξξξξξξ ξξξ ξ ξξξξ ξξξξξξ ξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξί° ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξ!"ξξ"ξξ # ξξξξξξξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξ ξ $ξξξξξξξ ξξί° ξξξξί° ξξξξξξξξ !ξξξ% ξξξξξ*ξ#ξξ , ξ-ξξξ ξξξξξξξ ξξξ*"ξξξξξξξξξξξξξ ξξξ ξξξ ξξξξ ξξξξξξ "ξξξ ξ ξξξξξ ξξξ ξξξξ ξξξξξ*ξ#ξξ , ξ-ξξξ ξξξξξξξ ξξξ*"ξξξξξξξξξξξξξ ξξξ ξξξ ξξξξ ξξξξξξ "ξξξ ξ ξξξξξξξξ ξξξξξ ξξξ ξξ ξξξξξξξξξξξξ ξξξξ"ξξξ ξξξξξξ "ξξξ ξξξξξξξξ ξξ%ξξ ξί°ξ ξξ ξ ξ . ξξ ξξξξξ ξξξξξ ξξ ξξξ% ξξ ξξξξξξξξ ξξ ξξ ξξξξξξξξξ ξξξξξ ξξξξ% ξξ%ξξ ξξξ ξξξξ ξ&ξξξξξξ ξξξ/ξ ξ ξ% ξξξξξξ ξξξξξξξξ% ξξ%ξξ ξ#ξξ ξξ ξξξξξ ξξξξξ ξξ ξξξξ ξξ ξξξ% ξξ ξξξξξξξξ ξξ ξξ ξξξξξξξξξ ξξξξξ ξξξξ% ξξξ ξξξ ξξξξ ξξξξξξ ξξξξξξξξ "ξξξξξξξξ ξξξ ξξί°ξξ ξξξξ ξξ ξξξξ ξξξξξξ ξξξξξξξξξξ ξξξξξξξξ ξξξξξξξ ξ ξ ξξξ"ξξξξξξξ ξξξξ ξξί°ξξξ ξξξ ξξ" ξξ"ξ ξξξξ ξξξ%ξ%ξ $ ξξξξξξξ ξξξξξξξ ξξί°ξξξ ξξξ ξξ" ξξ"ξ ξξξξ ξξξ%ξ%ξ ξξ ξ ξξξ ξξξξ ξξί°ξξξ ξξξ ξξ" ξξ"ξ ξξξξ ξξξ%ξ%ξ ξξ ξξξξξξξξξ ξξ ξξξξξ +ξ ξξξξ ξξξξ ξξ ξξξξξ ξξξξξξ ξξξξξ ξξξξξξ ξξξξ ξξξξ ξξξξξξξ ξξξξξξξξ "ξξξξξξξξ ξξξξξξ ξξξξξξ% ξξξξξξ ξξξξξξξ ξξξξξ ξξ ξξξ ξξ ξξ ξξξξξ ξξξξξξ ξξξξξ ξξξξξξ ξξξξ ξξξξ ξξξξξξξ ξξξξξξξξ "ξξξξξξξξ ξξξξξξ ξξξξξξ% ξξξξξξ ξξξξξξξ ξξξξ ξ$ ξξξξ ξξξξξξξ ξ0ί°ξ"ξξξξ ξξξξξξξξξξ ξξξ ξξί°ξξ ξξξξ ξξ ξξξξ ξξξξ ξξξξξ ξξ&ξ 'ξξξ( ξξξξ ξξξξξ ξ$$ 'ξξξ( ξξξ ξξξξξ ξξ&ξ 'ξξξ( ξξξ ξξξξξ ξ$$ 'ξξξ( ξξξξξξ ξξξξξ ξξ&ξ 'ξξξ( ξξξξξξ ξξξξξ ξ$$ 'ξξξ( ξξξξξξξξ ξξξξξ ξξ&ξ 'ξξξ( ξξξξξξξξ ξξξξξ ξ$$ 'ξξξ( ξξξξξ ξ ξξξξξξξξξξ ί°ξξξ ξ ξ ξ ξ ξ ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' $ ξ ξ ξξξ"ξξξξξξξ ξξξξ ξ#ξξ ξξ ξ#ξξ ξξ ξ ξ 1ξ2 ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' ξ' )' $ ξ ξξξξξξξξ ξξξξξξξ ξ ξ ξ ξ ξ ξ ξ#ξξ' ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' $ ξ ξξξξ ξί°ξξ ξ#ξξ ξξ ξ ξ ξ ξ ξ ξ ξ' ξ $ ξξξξξξξ ξξξξξξξ ξ#ξξ ξξ ξ#ξξ ξξ ξ ξ ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' ξ' $ ξξ ξξξξξξξξξξ ξξξξξ ξξξξ ί°ξξξ ξ ξ ξ ξ ξ ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' $ ξξ ξ ξξξξξξξ ί°ξξξ ξ#ξξ ξξ ξ#ξξ ξξ ξ ξ#ξξ ξξ ξ ξ ξ' ξ' ξ' ξ ξξ ξξξξξξξξξ ξξ ξ#ξξ ξξ ξ#ξξ ξξ ξ ξ ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' ξ' $ ξξ ξξ"ξξξξξ ξξξξ ξξξ ξ#ξξ ξ ξ ξ ξ ξ ξ ξ' ξ' ξ ξξ ξξξξξ ξξξξξξ ξξξξξξ ξ#$ξ ξξ ξ ξ ξ ξ ξ ξ ξ' ξ' ξ ξ) ξξξ" ξξξξ ξ ξ ξ ξ ξ ξ ξ#ξξ ξξ ξ%ξ% ξ' ξ' ξ' $ ξξ ξξξ ξ ξξ& ξξξξξξ ξ#ξξ ξξ ξ ξ ξ ξ ξ ξ ξ' ξ ξ$ ξξ"ξξξξξ ξξξξ ξξξ ξ#ξξ ξ ξ ξ ξ ξ ξ ξ' ξ' ξ ξξ ξξξξξ ξξξξξξ ξξξξξξ ξ#$ξ ξξ ξ ξ ξ ξ ξ ξ ξ' ξ' ξ ξξξξξ* ξ% ξ0ί°ξ"ξξξξ "ξξξξξξξ ξξ ξξξ ξξξ% "ξί°ξξξξξ ξξξξξξξξξξ ξξ ξξξ ξξί°ξξ ξξξ ξξξ ξξξξ ξξξξξ ξξξξξξξξξξ ξξ ξ0ί°ξ"ξξξξ% ξ% "ξξξξξξ ξξξξξξξ ξξξξξξ ξξ ξξξξξ "ξ"ξξξ ξξξξξξξ ξξξξ "ξξξξ ξξ ξ0ί°ξ"ξξξξ% ξ% ξξξξξξξξ ξξξξξ "ξ"ξξξ ξξ ξξξ ξξ ξξ"ξ ξξξ ξξ""ξξ 1ξξξξ ξξξξξ2 ξξξξξξξξξξ ξξξξ ξξξξξ ξξξ ξξξξξξξξ ξξξ +ξξξ ξξξξξξξξξ ξξξξξξ% "ξξξξξξ ξξξ" ξξ ξξξξξξξξ ξξξξξ "ξ"ξξξ ξξ ξξ ξ&ξξξξξ ξ ξξξξ ξξ ξξξξξξ"ξξ ξξξξξξ ξξξξί°ξξξ ξ ξξξ!ξξξξξξξ% ξ% ξξί°ξξ ξξξξξξξξ ξξξξξ "ξ"ξξξ ξξ ξ ξξξ ξξ "ξξξξξξξ 1ξξ ξξξξξ ξξξ ξξ""ξξξ ξξξξξ2 ξξξξ ξ0ί°ξ"ξξξξ ξξ ξξξξξ ξξξξ"ξξξ ξξξ "ξξξξξξ ξξξ ξξ"% ξ% "ξί°ξξξξξ ξξξξξξξξξξ ξξ ξξξ "ξξξξξξ ξξ ί°ξξξξξ ξξξ ξξξ&ξξξξ ξξξξξξξξξξ ξξ ξξξξξ ξξξξξξ ξξξ ξξξ&ξξξξ ξξξξξξξξξξ ξξξξ ξξξξξ ξξξξξξ ξξ ξξ"ξξξξξ ξξξξ ξξξ% ξ% "ξξξξξξ ξ ξξξξξ ξξί°ξξξξξξξ ξξ&ξξξ ξξξξξ ξξ ξξ ξ ξ ξξ ξξξξξ ξί°""ξξ ξξξ ξξξ ξξξξξξξ ξξξ"ξξξξί°ξξ ξξξ ξξξ/ξ )% "ξξξξξξ ξ ξξξξξ ξξί°ξξξξξξξ ξξ&ξξξ ξξξξξ ξξ ξξ ξ ξ ξξ ξξξξξ ξί°""ξξ ξξξ ξξξ ξξξξξξξ ξξξ"ξξξξί°ξξ ξξξ ξξξ/ξ $% "ξί°ξξξξξ ξξξξξξξξξξ ξξ ξ&ξξξξ ξξξξξ ξξξξ ξξ ξξξξξ ξξξξ"ξξξ ξξ ξξ0ί°ξξξξ% ξξξξξξξ ξξξξξ ξ% ξξξ ξξξξξξξξξξξ ξξξξξξξ ξξξξ ξξξ "ξί°ξξξξξ ξξί°ξξ ξξξ ξξξξξξξξξξ ξξξ ξ0ί°ξ"ξξξξ ξξξξξξξξξ% 01/11/18 TRASHTRASHTRASH$$ TRASHTRASHTRASH3938 37 8 30 35 31 44 45 43 9.2 48 47 48 49 50 52 51 53 56 56 54 55 53 53 58 57 D D D R D R D CHD D D D CH DD D CH D C H D TRASHD DD $ TRASHTRASHTRASHD D TRASH$ C3938 37 8 30 35 31 44 45 43 9.2 48 47 48 49 50 52 51 53 56 56 54 55 53 53 58 57 DD D R D R D C HD D D D CH DD D CH D C HD TRASHD D D $TRASHTRASHTRASHD DTRASH$ C2" V 4" GW FSK-01 FSK-01 FSK-01 FSK-01 FSK-01 FCO FLD-01 FLD-01 3" SAN 4" SAN 4" SAN 4" SAN 4" SAN 2" SAN 4" SAN 3" SAN 4" SAN 4" SAN 4" SAN MADE MARKET 105 DISHWASHING 106 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 PREFUNCTION 152 11 AAV 1/8" PER FT 1/4" PE R FT4" SAN 2" V 22.46 1" HW 1" CW 22.30 22.31 22.32 1" CW 1/2" CW1/2" CW 3/4" CW 1" HW 1/2" CW 3/4" HW 3/4" HW 1/2" HW 1211 6 8 6 4 21 14 MADE MARKET 105 DISHWASHING 106 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 LOBBY BAR 103 PREFUNCTION 152 30 1/2" CW INDIRECT WASTE PIPING MINIMUM 2X PIPE DIAMETER AIR GAP STAINLESS STEEL 1/2 GRATE DEEP SEAL TRAP STAINLESS STEEL DOME BOTTOM STRAINER STAINLESS STEEL INTERIOR FLOOR PIPE SUPPORT 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 2:12:05 PMENLARGED BAR & MADE MARKET PLAN THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P402 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE:1/4" = 1'-0"DRAWING REF:P1113AENLARGED BAR AND MADE MARKET PLAN - WASTE AND VENT SCALE:1/4" = 1'-0"DRAWING REF:P1116AENLARGED BAR AND MADE MARKET PLAN - DOMESTIC WATER NOT TO SCALE1B FLOOR RECEPTOR DETAIL PLAN KEYNOTES 22.30 RUN 1" HW & CW BELOW FLOOR TO BAR. NO FITTINGS TO BE INSTALLED BELOW SLAB. 22.31 TIE INTO EXISTING 140°F HW. VERIFY LOCATION. 22.32 1/2" CW BELOW FLOOR TO BACK OF BAR. NO FITTINGS TO BE INSTALLED BELOW SLAB. 22.46 OPEN SITE DRAIN FOR ESPRESSO MACHINE BAR AND MADE MARKET BACKFLOW PREVENTER SCHEDULE ITEM NO ITEM DEVICE APPLICABLE STANDARD REMARKS 4 3 COMPARTMENT SINK FAUCET AIR GAP TYPE ASSE 112.1.2 8 BLENDER STATION FAUCET AIR GAP TYPE ASSE 112.1.2 11 HAND SINK FAUCET AIR GAP TYPE ASSE 112.1.2 12 GLASSWASHER WATTS 9D ASSE 1012 14 WATER FILTER WATTS SD3-MF ASSE 1022 INSTALL BACKFLOW PREVENTER BEFORE FILTER. FILTER SERVING ITEMS 13 AND 21 30 WATER FILTER WATTS SD3-MF ASSE 1022 INSTALL BACKFLOW PREVENTER BEFORE FILTER. FILTER SERVING ITEM 28 FOOD SERVICE EQUIPMENT CONNECTION SCHEDULE ITEM NO ITEM COLD WATER SIZE (IN.) COLD WATER AFF (IN.) HOT WATER SIZE (IN.) HOT WATER AFF (IN.) DIRECT DRAIN SIZE (IN.) DIRECT DRAIN AFF (IN.) INDIRECT DRAIN SIZE (IN.) INDIRECT DRAIN AFF (IN.) NOTES 3 DRAINBOARD UNIT - - - - - - 1/2" TO F.S. 1, 3, 4, 8 4 3 COMPARTMENT SINK 1/2" 12 1/2" 12 - - (3) 1 1/2" TO F.S. 1, 2, 3, 4, 7, 8 5 COCKTAIL STATION - - - - - - 3/4", 1 1/2" TO F.S. 1, 3, 4, 8 6 SODA GUNS 1/2" 12 - - - - - - 1, 2 8 BLENDER STATION 1/2" 12 1/2" 12 - - 1 1/2" TO F.S. 1, 2, 3, 4, 8 10 DRAINBOARD GLASS RACK UNIT - - - - - - 1/2" TO F.S. 1, 3, 4, 8 11 HANDSINK UNIT 1/2" 20 1/2" 20 1 1/2" 12 - - 1, 2, 3, 6 12 GLASSWASHER 1/2" 12 1/2" 12 - - 1 1/2" TO F.S. 1, 2, 3, 4, 8 13 ESPRESSO MACHINE 1/2" - - - - - - 1, 2, 5 14 WATER FILTER SYSTEM 3/8" 12 - - - - - - 1, 2, 5 17 DRIP TRAY - - - - - - 1/2" TO F.S. 1, 3, 4, 8 21 BAG N BOX SYSTEM 1/2" 12 - - - - - - 1, 2 28 ESPRESSO MACHINE 1/2" - - - - - - 1, 2, 5 30 WATER FILTER SYSTEM 3/8" 12 - - - - - - 1, 2, 5 NOTES: 1. EQUIPMENT PROVIDED BY OTHERS. PLUMBING CONTRACTOR SHALL ROUGH-IN AND MAKE FINAL CONECTIONS TO EQUIPMENT. 2. PROVIDE SERVICE VALVES ON WATER PIPING SERVING EACH PIECE OF EQUIPMENT. 3. INIDRECT WASTE PIPING SHALL BE TYPE DWV COPPER (ASTM B-306) ASSEMBLIES WITH MATCHING FITTINGS AND 95-5 LEAD-FREE SOLDER. PROVIDE TRAP ON INDIRECT WASTE PIPING THAT EXCEEDS 2 FEET IN DEVELOPED LENGTH MEASURED HORIZONTALLY. 4. ROUTE INDIRECT WASTE PIPING AS HIGH AS POSSIBLE (TO ALLOW FOR MOPPING FLOOR) FROM EQUIPMENT TO FLOOR RECEPTOR AND PROVIDE AIR GAP. 5. PLUMBING CONTRACTOR SHALL PROVIDE SHUT-OFF AND FLEXIBLE CONNECTION TO WATER FILTER AND FLEXIBLE CONNECTION FROM WATER FILTER TO ESPRESSO MACHINE. 6. PROVIDE A WATTS LFUSG-B-M2 MIXING VALVE ON THE HOT WATER SUPPLY AND SET LEAVING TEMPERATURE FOR 105°F 7. PROVIDE A WATTS LFUSG-B-M2 MIXING VALVE ON THE HOT WATER SUPPLY AND SET LEAVING TEMPERATURE FOR 120°F 8. PLUBMING CONTRACTOR TO EXTEND DRAIN LINE TO FLOOR RECEPTOR AS REQUIRED. GENERAL NOTES 1. SEE FOODSERVICE DRAWING K201 FOR PLUMBING ROUGH-IN DIMENSIONS AND EQUIPMENT LOCATIONS. 13 12/01/2017 CCD-09 12/01/2017 01/11/18 GGDD D CWOD D D CGGD D D CWO DD D C3/4" CW 3/4" HW (140°) 1/2" CW 1/2" HW (140°) 2" G 1 1/2" G 3/4" G 3/4" G 3/4" G 3/4" G 3/4" G 22 22.61 1/2" HW (140°) 1/2" CW 24 27.1 27, 28 8 9 9 13 3 1 33 45 31 30 33 22 22 1/2" CW 1/2" HW (140°) 1/2" HW (140°) 1/2" CW 1/2" CW 1/2" HW (140°) 22.62 2" G 1/2" HW (140°) 1/2" CW 22.63 36 1/2" HW (140°) 1/2" CW 1/2" HW (140°) KITCHEN 151 3/4" HW (140°) 3/4" HW (140°) 1/2" CW KITCHEN 151 22 27, 28 8 33 29.1 29.2 45 31 30 33 22 22 3" FLD-01 FSK-01 FSK-01 3" SAN 2" V 2" SAN 4" GW 2" SAN 3" SAN 4" GW 4" GW 2" V FSK-01 2" V 2" SAN 2" SAN 2" V 4" GW 4" GW 22.64 2" V 4" GW 3" GW 2" V 2" V2" V 22.69 2" V 3" SAN 2" SAN 2" SAN 2" SAN 22.69 2" V 2" SAN FSK-01 FSK-01 FSK-01 3" FLD-01 2" SAN 2" SAN 4" GW 4" GW 2" V 2" V 2" SAN 3" SAN 2" V 2" V 2" V 2" V 2" V 2" SAN 3" VTR 22 22 8 45 22 2" V 2" SAN 2" SAN 2" V 2" V 2" SAN 2" OPEN SITE DRAIN 3" SAN 3" SAN MAU-1 - 313 MBH 2" G 2" G 36 - 125 MBH 9 - 110 MBH 13 - 164 MBH 3 - 56.6 MBH 1 - 80 MBH 17 - 106 MBH 12 - 25 MBH 1 1/2" G 9 - 110 MBH 3/4" G 1" G 1 1/4" G 1 1/2" G 1 1/2" G1 1/2" G RTU-A1 - 300 MBH 1 1/4" G 1 1/4" G UP THROUGH ROOF 613 MBH 235 MBH 345 MBH 370 MBH 534 MBH 590.6 MBH670.6 MBH 776.6 MBH 1389.6 MBH 1" G 1 1/4" G 1 1/4" G MAU-1 RTU-A1 22.66 22.66 22.65 22.67 DRIP/DIRT POCKET 18" MIN CONNECT TO UNIT GAS CONTROLS; PROVIDE GROMMET FOR WATERTIGHT SEAL 3" MIN ROOF PIPESTAND GAS PIPE GROUND JOINT UNION ROOFTOP UNIT GAS COCK WITH 0.125" NPT TEST GAUGE CONNECTION PRESSURE REDUCING VALVE WITH INTERNAL VENT PLUGGED 0.125" NPT TEST GAUGE CONNECTION 1 A 2 3 4 5 6 ABCDE13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.BCDEDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®1/5/2018 12:58:28 PMENLARGED KITCHEN PLANS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P403 2211 N FRONTAGE RD, VAIL, COLORADO 81657 10 9/15/17 CCD-06 13 12/01/2017 CCD-09 15 1/3/2018 CCD-09 REV1 SCALE:1/4" = 1'-0"DRAWING REF:P1114AENLARGED KITCHEN PLAN - DOMESTIC WATER & GAS SCALE:1/4" = 1'-0"DRAWING REF:P1113AENLARGED KITCHEN PLAN - WATSE & VENT 22.61 1/2" CW DOWN TO WATER FILTER. ICE MACHINE (ITEM 27) TO BE SERVED FROM WATER FILTER. 22.62 EXISTING MAIN GAS VALVE FOR KITCHEN. TIE INTO EXISTING MAIN GAS RISER. 22.63 1 1/2" GAS PIPING UP TO SERVE MAU-1 & RTU-A1 ON ROOF. SEE PARTIAL ROOF PLAN ON THIS SHEET FOR CONTINUATION. 22.64 TIE NEW 3" VENT THROUGH ROOF INTO EXISTING VENT PIPING. 22.65 1 1/2" GAS UP THROUGH ROOF. 22.66 CONNECT GAS PIPING TO EQUIPMENT PER DETAIL 5E ON THIS SHEET. 22.67 3" VENT THROUGH ROOF. EXTEND 24" ABOVE ROOF SURFACE, AND LOCATED A MINIMUM OF 10' FROM ANY MECHANICAL FRESH AIR INTAKE. 22.69 EXISTING FLOOR SINK PLAN KEYNOTESKITCHEN FOOD SERVICE EQUIPMENT SCHEDULE ITEM NO. ITEM COLD WATER SIZE (IN.) COLD WATER AFF (IN.) HOT WATER SIZE (IN.) HOT WATER AFF (IN.) DIRECT DRAIN SIZE (IN.) DIRECT DRAIN AFF (IN.) INDIRECT DRAIN SIZE (IN.) INDIRECT DRAIN AFF (IN.) GAS SIZE (IN.) MBTU NOTES 1 COUNTER CHARBROILER - - - - - - - - 3/4 80 1, 2, 9 3 COUNTER CHARBROILER - - - - - - - - 3/4 56.6 1, 2, 9 8 MOP SINK 1/2 36 1/2 36 2 - - - - - 1, 2 9 FRYERS - - - - - - - - 3/4 110 1, 2, 9 12 SALAMANDER BROILER - - - - - - - - 1/2 28 1, 2, 9 13 4-BURNER RANGE - - - - - - - - 3/4 164 1, 2, 9 17 DOUBLE CONVENCTION OVEN - - - - - - - - 1 106 1, 2, 9 22 HAND SINK 1/2 20 1/2 20 1 1/2 16 - - - - 1, 2, 6 24 BEVERAGE STAND 1/2 12 1/2 12 - - 1, 1 1/2 TO F.S. - - 1, 2, 3, 4 27 ICE MACHINE 1/2 - - - - - 3/4 TO F.S. - - 1, 2, 5 27.1 WATER FILTER 1/2 60 - - - - - - - - 1, 2, 5 28 ICE BIN - - - - - - 3/4 TO F.S. - - 3, 4 29.1 EVAPORATOR COIL - - - - - - 3/4 TO MOP SINK (8) - - 3, 4 29.2 EVAPORATOR COIL - - - - - - 3/4 TO MOP SINK (8) - - 3, 4 30 SOILDED DISHTABLE 1/2 1/2 - - 1 1/2 TO F.S. - - 1, 2, 3, 4, 8 31 DISHMACHINE (BOOSTER HEATER) - - 1/2 12 - - 1 1/2 TO F.S. - - 1, 2, 3, 4, 8 33 3-COMPARTMENT SINK 1/2 12 1/2 12 - - (3) 1 1/2 TO F.S. - - 1, 2, 3, 4, 7, 8 36 HEARTH PIZZA OVEN - - - - - - - - 3/4 125 1, 2, 9 45 DROP-IN HAND SINK 1/2 20 1/2 20 1 1/2 16 - - - - 1, 2, 6 NOTES: 1. EQUIPMENT PROVIDED BY OTHERS. PLUMBING CONTRACTOR SHALL ROUGH-IN AND MAKE FINAL CONECTIONS TO EQUIPMENT. 2. PROVIDE SERVICE VALVES ON WATER PIPING SERVING EACH PIECE OF EQUIPMENT. 3. INIDRECT WASTE PIPING SHALL BE TYPE DWV COPPER (ASTM B-306) ASSEMBLIES WITH MATCHING FITTINGS AND 95-5 LEAD-FREE SOLDER. PROVIDE TRAP ON INDIRECT WASTE PIPING THAT EXCEEDS 2 FEET IN DEVELOPED LENGTH MEASURED HORIZONTALLY. 4. ROUTE INDIRECT WASTE PIPING AS HIGH AS POSSIBLE (TO ALLOW FOR MOPPING FLOOR) FROM EQUIPMENT TO FLOOR RECEPTOR AND PROVIDE AIR GAP. 5. PLUMBING CONTRACTOR SHALL PROVIDE SHUT-OFF AND FLEXIBLE CONNECTION TO WATER FILTER AND FLEXIBLE CONNECTION FROM WATER FILTER TO ICE MAKER 6. PROVIDE A WATTS LFUSG-B-M2 MIXING VALVE ON THE HOT WATER SUPPLY AND SET LEAVING TEMPERATURE FOR 105°F 7. PROVIDE A WATTS LFUSG-B-M2 MIXING VALVE ON THE HOT WATER SUPPLY AND SET LEAVING TEMPERATURE FOR 120°F 8. PLUBMING CONTRACTOR TO EXTEND DRAIN LINE TO FLOOR RECEPTOR AS REQUIRED. 9. PROVIDE QUICK DISCONNECT FOR GAS PIPE CONNECTION. KITCHEN BACKFLOW PREVENTER SCHEDULE ITEM NO. ITEM DEVICE APPLICABLE STANDARD REMARKS 8 MOP SINK FAUCET AIR GAP TYPE ASSE 112.1.2 22 HAND SINK FAUCET AIR GAP TYPE ASSE 112.1.2 24 BEVERAGE STAND FAUCET AIR GAP TYPE ASSE 112.1.2 27.1 WATER FILTER WATTS SD3-MF ASSE 1022 INSTALL BACKFLOW PREVENTER BEFORE FILTER. FILTER SERVING ITEM 27 30 SOILED DISHTABLE FAUCET AIR GAP TYPE ASSE 112.1.2 31 DISHMACHINE WATTS 9D ASSE 1012 33 3-COMPARTMENT SINK FAUCET AIR GAP TYPE ASSE 112.1.2 45 DROP-IN HAND SINK FAUCET AIR GAP TYPE ASSE 112.1.2 NOT TO SCALE6AKITCHEN WASTE & VENT RISER DIAGRAM NOT TO SCALE6CKITCHEN GAS RISER DIAGRAM SCALE: 1/4" = 1'-0"2C PARTIAL LOW ROOF PLAN NOT TO SCALE5E GAS CONNECTION TO EQUIPMENT DETAIL GENERAL NOTES 1. SEE FOODSERVICE DRAWING K202 FOR PLUMBING ROUGH-IN DIMENSIONS AND EQUIPMENT LOCATIONS. REMOVED FIXTURES FROM EXISTING KITCHEN: -3-COMPARTMENT SINK -DISHTABLE -DISHMACHINE FIXTURES ADDED TO NEW KITCHEN - (2) 3-COMPARTMENT SINKS WITH BOWL DIMEINSIONS (16βX20βX18β) -DISHTABLE (20βX20βX5β BOWL) -DISHMACHINE TOTAL EQUIVALENT NEW DRAINAGE LOAD -3-COMPARTMENT SINK DRAINING IN 1 MINUTE: 25 GPM NEW 1500 GALLON GREASE INTERCEPTOR TO BE ADDED TO EXTISTING 1500 GALLON CAPACITY GREASE INTERCEPTOR TO MAKE TOTAL GREASE HOLDING CAPACITY 3000 GALLONS 01/05/2018 01/11/18 ξξ ξξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξ ξ ξξ ξξ ξξξ ξξξξξ ξξξξξ ξ ξ ξξξ ξ ξξξξ ξξξ ξξξξ ξξξξξξ ξξξξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξ ξ ξξ ξξξξξ ξξξξξ ξξ ξξξ ξξξξ ξξξξ ξξξξξξ ξ ξ ξξξ ξξξξ ξ ξξξξξ ξ ξξ ξξ ξξξ ξξ ξ ξξξξξ ξξξξξξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξ ξξξ ξξξ ξξξ ξξξ ξξξ ξξ ξξξ ξ ξ ξξξ ξ ξ ξξξ ξξ ξξξ ξ ξ ξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξ ξξξξ ξξξξξξ ξξξξ ξξξξ ξξ ξξξξ ξξξξξξ ξ ξξξξ ξξξ ξξξξξξ ξ ξ ξξξ ξξξξξ ξξ ξξξ ξξξξξ ξξξξ ξξ ξξ ξξξ ξ ξξξξ ξξξ ξξξξξξ ξξξξξξξξξξξξξξξ ξξξξ ξξξξ ξ ξξξξ ξ ξξξξ ξ ξξ ξξξ ξ ξ ξξξ ξξξξξ ξξξξξ ξξξξ ξξξξξξ ξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξί°! ξξξξ "ξξξ#ξξξξξξ $ξ# ξξ !ί°ξξ ξξξξ ξξ ξί°ξξ# ξξ ξξ ξξξ! ξξ ξξξ"ξξξ#ξ ξξ!ί°ξ$! #%ξξ#ξξ#ξ ξξξ!!#ξ ξξξξ#ξ!ξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ "ξ% ξ ξξξ ξξξί°&ξξξξ ξξ ξξξξ'ξξξ ξξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ( ξξξξξξξξξξ ξ)ξξ)ξ ξ ξ&ξξξξξξξξ ξξξξξξξξξ ξξξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξί°!ξξ!ξξ " ξξξξξξξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξ ξ #ξξξξξξξ ξξξ ξξξξξ ξξξξξξξξ ί°ξξξ$ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξξξξ ,ξ& ξ ξξ- ξ ξ#&ξξξ!ξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξ ξξξ ,ξ& ξ ξξ- ξ ξ#ξ ξξξξ ξξξξ#) ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξξξ ,ξ& ξ ξξ- ξ ξ#&ξξξ!ξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξξξ ,ξ& ξ ξξ- ξ ξ#ξ ξξξξ ξξξξ ξ#ξξξ!#ξ ξξξξ ξ ξ#&ξξ# ξξξξ!ξξξξ ξξ$ξ#!ξ ξξξ ξξξξξξ ξξξξ ξ ξ#&ξξ# ξξ!#ξ ξξξξ#! ξξξ ξξξξξξ ξξξξ ξ ξ#&ξξ# "ξ!ί°!$"ξ ξί°ξξ#ξξ!$" ξξξ!ξξξξξ "ξ!ί° ξξξ$!ξ ξί°ξξ#ξί°#ξξξ ξξξ ξξξξξξξ ξξξξ ξ ξ#&ξξ# ξξξξξ ξξξξ ξξξ ξξ!ξί° ί°ξξ# ξξξ ξ#ξ ξξξξξί°ξ ξξξξ ξ ξ#&ξξ# ξξξί°#ξ "ξ%#ξ ξξξ ξξξξξξ !ξ &ξξξξξ ξξξξξ ξξξ!ξξξ ξ#ξ ξξξξ!ξξξ ξξξ ξξ$ξ#!ξ ξ#ξξξξ #%ξξ!ξξξ ξξξξξξ !ξ ξξξξ#ξ! !ξ &ξξξξξ ξξξξξ ξξξ!ξξξ ξ#ξ ξξ!#ξ ξξξξ#!ξ ξ#ξξξξ #%ξξ!ξξξ ξξξξξξ !ξ ξξξξ#ξ! !ξ ξξξ!# ξ!ξξξ ξξξ ξξξ ξξξξξ ξξξ!ξξξ ξ#ξ "ξ!ί°!$"ξ ξξξ!ξξξξξ ξξξ$!ξ ξξξ ξί°ξξ#ξί°#ξξξ ξ#ξξξξ ξξξξξξ !ξ ξξξξ#ξ! !ξ #%ξξ!ξξξξ ξ#ξ#ξξξ ξξ!#ξ ξξ ξξξ ξξ%!$ξ#ξ "#ξξξ ξ#ξξξξ#ξ ξί°ξξξ ί°ξξ# ξ#ξ ξξ!#ξ ξ$ξξξξ ξ!ξξξξ ξξ!ξξξξξ ξξξ ξξξξ #ξξ$!ξί°#ξξξξ ξξ ξξξ ξξξξ!ξξξ#ξ ξί°ξξξ ί°ξξ# ξ$ξξξξ ξ!ξξξ ξξξ ξξ!ξξξ ξξξ$ξξ!ξξξ ξξξ!ξξξ#ξ #ξ$ξξ !ξ !ξ$#"ξξ ξξξξξξ$ξξξξξξξ ξξ ξ#ξξξξ ξξξξ!ξξξξ ξξ #%ξξ!ξξξ ξξξξξξ ξξ!ί°ξξ ξξ$&"ξξξ ξί°ξξ#ξ ξξξ ξ"ξξ# ξ#ξξξξξξ ξξ ξξ#ξξξ ξ ξ ξ#ξξξξξ #%ξξ!ξξξ ξξ&#ξ!ξξ ξξ!#ξ ξξξξξξ !ξ !ξ# ξξ!ξ ξ#ξ ξξ$&"ξξξ ξξ%!$ξ# ξξξξ!ξξξξξ ξξξξ#) ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ)ξξξξ ξ ξξξξξξ ,ξ& ξ ξξ- ξ ξ#&ξξξ!ξξξ ξξξξ#) ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξξξξξξξ ,ξ& ξ ξξ- ξ ξ#ξ ξξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξξξ#ξξξξξ#ξ ξ./ ξξξξξ ξξξξ ξ ξ#&ξξξ!ξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξξξ#ξξξξξ#ξ ξ./ ξξξξξ ξξξξ ξ ξ#ξ ξξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξξξξξ ,ξ& ξξξ- ξ ξ#&ξξξ!ξξξ ξξξξ#)ξξξ ξ * ξ+ξξξ ξξξξξξξ ξ#ξ) ξξξξ ξξξξ ,ξ& ξξξ- ξ ξ#ξ ξξξξ ξ 'ξξξξξξξξ ξ012324. ξ 01/11/18 01/11/18 ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξ ξξξξξ ξξξξ ξξ ξξξ ξξξξξ ξξξξξξ ξξ ξξξ ξξ ξ ξξξξξ ξξξξξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξξξξξξξ ξξ ξξ ξξξξξξξξξξξ ί°ξξ ξξ ξξξξ !ξξξ ξξ !ξξξξ ξξ ξξ ξξξξ ξξ ξξξξξ""ξξ !ξξξξί°ξ ξ#ξξξξξξ" !ξξξξξξ ξξξξξξξξξ ξ ξ ξξξξξξξξ ξξξ ξξξξ ξξ# ξξ ξ ξ ξξξξ$ξξ"ξ ξξ ξξξξ%ξξ ξξ ξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ &ξξ 'ξ('ξξ ξξ ξ)ξξ)ξξ ξ$ξξξξξξξξ ξξξξξξξξξ ξξξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξί°!ξξ!ξξ " ξξξξξξξξξξξξ ξξξξξξξξξ ξξ ξξ ξξξξ ξ #ξξξξξξξ ξξξ ξξξξξ ξξξξξξξξ ί°ξξξ$ ξξξξξ) ξ'ξξ * ξ+ξξ ξ "ξξ!ξξξ ξξξ)ξξξξξξξξξξξ ,ξ$ ξξξ- ξ "ξ$ξξξξξξξ ξξξξξ) ξ'ξξ * ξ+ξξ ξ "ξξ!ξξξ ξξξ) ξξξξξξξξξξξ ,ξ$ ξξξ- ξ ξξ! !ξξξ ξξξξ ξξξξξξξξ ξξξξξ ξξ$ξξξ ξξξξξξξξξ ξξί°ξξξξ ξξ" ξξξξξξ ξξξξξ ξξ$ξξξ !ξξξξ ξξξξξξ ξξ" ξξξξξξ ξξξξξ ξξ$ξξξ ξξξξξξξ ξξξ!ξξξ ξξξξξξξξξ ξξξ$ξ ξξξ!ξξξξξ"ξ ξξ" ξξξξξξξ ξξξξξ ξξξξξξξ ξξ! ξξξξξξξξ ξξ" ξξί°ξξξξ ξξ!ξξξ ξ#ξξξξξξ ξξξξξξ ξξ ξξξξξξξ ξξ $ξξξξξ ξξξξξ ξξξξξξξ ξξ! !ξξξξ ξξξξξξξ ξξ!ξξξ ξ#ξξξξξξ ξξξξξξ ξξ ξξξξξξξ ξξ !ξξξξ ξξξξξ ξξ" ξ!ξ ξξξξξξξ ξξξξξ ξξ ξξξ ξξ#ξ ί°ξξξ ξξξξξ ξξξξξξξ" ξξξξξ ξξξξ ξξ! !ξξξξ ξί°ξξξξ ξξξξξξ ξξξξξξξξ ξξ" !ξξξ ξξξί°ξξξξξξξξ ξξ ξ"ξ ξξξξξξξξξξ ξξξξξ ξξξξ ξί°ξξξξ ξξξξξ ξξ" ξξξξξξ ξξξί°ξξξξξξ ξξξξξξξξ" ξξί°ξξ ξξ ξξί°ξξξξ ξξξξξξί°ξξ"ξξξξ ξξ ξξξξξξ ξξξξξξξξξ ξξ ξ#ξξξξξξ ξξξξξξ !ξξξξξ ξξί°$ξξξξ ξξξξξξ ξξ" ξξξξξ ξξξξξξξξ ξξ ξξξξ"ξ ξξ ξξξ!ξξξ ξ#ξξξξξξ "ξ$ξξξξξ !ξξξξ ξξξξξξ ξξ ξξξ ξξξξ ξξ! ξξί°$ξξξξ ξξ#ξ ί°ξξ ξξξξξξξξξξ ξ %'ξξ'ξξ ξξ ξ./01023 ξ 01/11/18 22.41 22.40 22.45 QQARI 235 22.51 PF-1 4" SAN 22.50 PF-2,3 2" SAN 2" V 22.54 PF-15 22.41 22.40 22.45 PF-15 22.51 22.50 PF-2,3 PF-1 4" SAN 2" SAN 2" V 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®7/21/2017 9:46:30 AMENLARGED GUESTROOM DETAILS THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS P411 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: P1121AQQARI (RM 235) - DEMOLITION SCALE: 1/4" = 1'-0" DRAWING REF: P1122AQQARI (RM 235) -NEW WORK PLAN KEYNOTES 22.40 REMOVE LAVATORY, FAUCET, AND PIPING 22.41 REMOVE WATER CLOSET AND PIPING 22.45 REMOVE ROLL-IN SHOWER, CONTROLS, TRIM, SHOWERHEAD, AND PIPING. 22.50 INSTALLNEW LAVATORY AND FAUCET. REWORK EXISTING PIPING TO CONNECT TO MAINS. 22.51 INSTALL NEW WATER CLOSET. REWORK EXISTING PIPING TO CONNECT TO WASTE STACK AND CW. GENERAL NOTES 1. ALL FIXTURES BEING REPLACED SHALL HAVE NEW WATER SUPPLY STOPS, P-TRAPS, AND WALL ESCUTCHEONS. 2. ADA LAVATORIES SHALL HAVE SUPPLY STOPS AND P-TRAP INSULATION INSTALLED EQUAL TO TRUEBRO "LAV-GUARD-2". 3. VERIFY LOCATIONS OF EXISTING PIPING WITHIN PLUMBING CHASES AND ABOVE CEILINGS IN FIELD. 4. RE-WORK EXISTING DOMESTIC WATER PIPING TO TIE INTO NEW PLUMBING FIXTURE LOCATIONS. 1 8/25/2016 FOR CONSTRUCTION SET 9 7/21/17 CCD-05 SCALE: 1/4" = 1'-0" DRAWING REF: P1123AKARI (RM 237) - DEMOLITION SCALE: 1/4" = 1'-0" DRAWING REF: P112 4A KARI (RM 237) - NEW WORK 07/31/2017 01/11/18 ξξξξξ ξ ξξξξξ ξ ξξξξξ ξξξξξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξξξξξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξ ξξξξ ξξ ξξ ξξξ ξξξξξ ξξξ ξξ ξξξ ξξ ξ ξξ ξξξ ξξ ξ ξξ ξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξ ξξξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξ ξξξξξ ξ ξξ ξξξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξ ξξ ξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξξ ξξξξξ ξ ξξ ξξξ ξξξξξ ξ ξξξξξ ξ ξξξ ξξξ ξξξξξ ξ ξξξξξ ξ ξξ ξξξ ξξ ξ ξξξ ξξ ξξξ ξξξ ξξξξξ ξξξξ ξξί° ξξ!ξξξ ξ ξξξξ ξξί° ξξ!ξξξ ξ ξξξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξ ξξξ ξ!ξξξξξξξ ξξξξξξ!ξξ ξ"!ξξ!ξξ #ξ ξξί° ξξξξξ ξξξ ξξί° ξξξξξ ξξ ξ ξξί° ξξξξξ ξξξ ξξί° ξξξξξ ξξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξξξ ξ!ξξξξξξξ ξξ ξξί° ξξξ ξξξ ξ!ξξξξξξξ #ξ ξξί° ξξξξ ξξ ξ ξξί° ξξξξ ξξ ξ ξξί° ξ$ξξ ξ$ξξ ξ% ξξ % ξξξ ξξξ ξ!ξξ ξξξξξ #ξ ξξί° ξ$ξξ &ξ% ξξ% ξξ% ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξ ξξξ ξ ξ ξ ξ ξξξ'ξ!ξί°ξ ξξ ξ# ξξξξξξξ!ξξ( ξξξ ξξ ξί°!ξ ξξξξ !ξ ξί°ξξξ ξξ !ξ ξξξξ !ξ ξξξξ!ξξξξ ξ!ξί°ξξξ ξ"ξξξξξξξ ξξ!ξξξξ ξξξξξξξ(ξ ξ ξ ξξξξξξξξ ξξξ ξ(ξ( ξξ" ξξ ξ ξ ξ!ξ ί°ξξξξξ ξξ ξξξξξξξ ξξ ξ ξξξξξξξ ξξξξξ ξξξξξ ξξξξξξξ ξξξξξ ) ξξ $ξ&$ξξ ξ# ξ*ξξ*ξξ ξξξξξξξ ξξξξξξξξ ξξξ ξξξξξξξξξξ ξξξξξ ξξξξξξξξξξ ξξξξξξξξξξ ξξξξξ ξξ ξξξξξξξξξξ ξξξξξξξξξξ ξ ξξξξξξ ξξξξξξ ξξξξξξξξξξ ξί°!ξξ!ξξ " ξξξξξξξξξξξξ ξξξξξξξξξ ξξξξ ξξξξ ξ #ξξξξξξξ ξξξ ξξξξξ ξξξξξξξξ ί°ξξξ$ ξξξ ξξ ξξξξξξξξξξξ ξξξ ξξξξξ'ξξ ξξξξξξξξ ξξξξξ ξξξ ξξξξ ξ!ξξξ ξ!ξξξξξ ξξξ ξξ ξξξξξξ ξξξξξ!ξ ξξξξξξξξξ ξξξξξ ξξξξξξ'ξ ξξξ ξξξ ξξξξξ ξξξ ξξξξ ξ!ξξξ ξξξξξξ ξξξ ξξ ξξξξξ ξ ξξξξ ξ!ξξξ ξ!ξξξξξ ξ ξ$ξξ$ξξ ξ# ξ+,-.-/0 ξ 01/11/18 01/11/18 01/11/18 01/11/18 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 40 41 42 43 44 45 46 47 29 30 31 32 33 34 35 36 37 38 39 KITCHEN 151 BALLROOM/ MEETING ROOM 104 MADE MARKET 105 MEETING STORAGE 153 2 3 2 2 1 1 2 2 4 1 5 6 6 7 8 9 NORTH (E) W18(E) W18 (E) W18 (E) W18 . 8 S2 8 S2 8 S2 7/S2 (E) 38" TRUSS600 S 162 - 54 MATERIAL THICKNESS: IN 1/1000 INCHES MEMBER DEPTH: IN 1/100 INCHES FLANGE WIDTH: IN 1/100 INCHES TYPE: S = STUD OR JOIST SECTIONS T = TRACK SECTIONS U = CHANNEL SECTIONS F = FURRING CHANNEL SECTIONS TYPICAL ANNOTATION SHEET TITLE: SHEET NUMBER: © MARTIN/MARTIN 2017DESIGNERS: DATE PRINTED: MM JOB #: PRINCIPAL: EOR: PROJECT MANAGER: Martin/Martin, Inc. considers that design data is only in its final form on plotted drawings with original signatures and professional certification being visibly present on the drawings. Data supplied via computer generated format does not contain this approval or certification. The receiver of electronically transmitted drawings is responsible for verifying the information contained within the electronic data against the recorded or approved documents.The use of electronically transmitted drawings is considered to be at your own risk. Martin/Martin, Inc. assumes no responsibility for any claims or damages resulting from your use of this information. Electronic information is provided for the convenience of the recipient only. The recipient of this file agrees that the information may not be transferred to any other party.PROJECT NO: DATE:5/19/2017 10:47:01 AMC:\Proj\MS17.0085-Doubletree Vail RoofRepair-RS17_seanm.rvtS1DOUBLETREE VAILBALLROOM ROOF REPAIR2211 N FRONTAGE RDWEST VAIL, CO 81657PLANKM SMEJMS17.0085.S.01MS17.0085.S.01 02/13/17 SM 1/4" = 1'-0" BALLROOM ROOF PLAN1 GENERAL NOTES 1. GENERAL DESIGN β’ INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2015 β’ IEBC 606.2.1 REPAIRS FOR LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE. FOR DAMAGE LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE, THE DAMAGED ELEMENTS SHALL BE PERMITTED TO BE RESTORED TO THEIR PREDAMAGED CONDITION 2. LOADS β’ CAPACITY OF EXISTING STRUCTURE IS APPROXIMATELY 75 PSF TOTAL LOAD 3. STEEL β’ PLATES AND ANGLES ASTM A36 β’ BOLTS ASTM A307 β’ TUBE ASTM A53 GrB β’ LIGHT GAGE β’ ASTM A1003 GR33 (STUDS β€ 43 MIL, TRACK) β’ ASTM A1003 GR50 (STUDS β₯ 54 MIL, PIPE) 4. WOOD β’ DOUGLAS FIR-LARCH #2 DRY (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF INSTALLATION) 5. STRUCTURAL COLD FORMED METAL FRAMING β’ 6. WELDS β’ WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS. QUALIFICATION TESTS β’ WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE β’ E70 ELECTRODE STRENGTH 7. EXISTING STRUCTURES β’ DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE SITE OBSERVATIONS AS PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN. β’ DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS WHICH ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT PER THE CONTRACT DOCUMENTS INCLUDING: β’ DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS β’ CONDITIONS OF INSTABILITY OR LACK OF SUPPORT β’ ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND IN THE FIELD β’ CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO CONSTRUCTION β’ CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES IN THE CONSTRUCTION SCHEDULE 8. USE OF DRAWINGS β’ DO NOT SCALE DRAWINGS β’ DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT. 9. TEMPORARY CONDITIONS β’ THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES β’ CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD 10. OSHA STANDARDS β’ THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO COMPLY WITH ALL OSHA REQUIREMENTS β’ THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS AND BRACING β’ WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL DRAWINGS REPRESENT FINAL CONDITIONS ONLY. THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING NECESSARY TO COMPLY WITH OSHA 11. SUBMITTALS β’ PROVIDE THE FOLLOWING SHOP DRAWINGS OF STEEL CONSTRUCTION INCLUDING β’ LAYOUT β’ DIMENSIONS β’ MEMBER SIZES β’ MATERIAL GRADES β’ WELD SIZES β’ WELD CALLOUTS β’ ASSEMBLIES β’ BOLT SIZE β’ LENGTH AND TYPE β’ OTHER PERTINENT DATA 12. CONSTRUCTION ENGINEERING β’ THE STRUCTURE DEFINED ON THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY TO RESTORE DAMAGED STRUCTURE TO ITS PREDAMAGED CONDITION. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO ACHIEVE THE MEANS, METHODS AND SEQUENCES OF WORK. SUCH ENGINEERING MAY INCLUDE BUT IS NOT LIMITED TO: β’ LAYOUT β’ DESIGN OF SHORING β’ WELD PROCEDURES β’ EVALUATION OF TEMPORARY CONSTRUCTION LOADS β’ SHORING: β’ THE AREA OF EACH SHORED MEMBER SHALL BE BLOCKED OFF AND CLEARED OF SNOW AND ICE β’ ALL SHORING SHALL REMAIN IN PLACE UNTIL REPAIRS ARE COMPLETE 1 1 INDICATES ROOF TRUSS AND TRUSS MEMBER FROM EAST SIDE OF FLAT ROOF NOTES INDICATES ROOF TRUSS REPAIR KEYNOTE FOR REPAIR NOTES SEE NO ISSUE DATE * 1 MIL = 1/1000" NOTE: 12 97 14 68 16 54 18 43 20 33 22 27 GAUGE MINIMUM THICKNESS (MILS*) METAL GAUGE CONVERSION β’ CONNECT NEW MEMBERS TO (E) BRIDGING β’ IF BRIDGING IS DAMAGED OR CANNOT BE RECONNECTED CONTACT STRUCTURAL ENGINEER 5/19/2017 01/11/18 01/11/18 01/11/18 01/11/18 01/11/18 AA A AAAA A 135 7 9 10 8 6 4 212 1416 18 20 22 24 26 11 1315 17 19 21 23 25 27 3/4" Ø PIN 3/4" Ø PIN 1 REPLACE MEMBERS BETWEEN NODES 12-13 2 REPLACE MEMBERS BETWEEN NODES 11-15 3 REPLACE MEMBERS BETWEEN NODES 12-17 4 REPLACE MEMBERS BETWEEN NODES 12-14 5 REPLACE MEMBERS BETWEEN NODES 14-15 AND 18-19 6 REPLACE MEMBERS BETWEEN NODES 13-15 7 REPLACE MEMBERS BETWEEN NODES 7-16 8 REPLACE MEMBERS BETWEEN NODES 8-13 9 REPLACE MEMBERS BETWEEN NODES 8-11 NOTES 1. VERIFY THAT MEMBERS SPECIFIED ARE DAMAGED 2. SELECT ONE OF THE OPTIONS ON 2/S2, 3/S2, 5/S2 OR 6/S2 TO COMPLETE REPAIR 3. IF ADDITIONAL TRUSSES OTHER THAN THOSE SPECIFIED ARE DISCOVERED TO BE DAMAGED, NOTIFY THE ENIGNEER 4. IF ADDITIONAL MEMBERS IN THE TRUSSES SPECIFIED ARE DISCOVERED TO BE DAMAGED, NOTIFY THE ENGINEER 1/2" Ø PIN 1/2" Ø PIN NORTH (E) MEMBER TO REMAIN FOR LOCATION SEE 1 1/4" Ø x 0.0598" TUBE CRIMP END INTO CONNECTION FOR LOCATION SEE 7/S2 REMOVE (E) PIN AND REUSE TO CONNECT NEW MEMBER IF NECESSARY REPLACE WITH BOLT OF EQUAL SIZE DO NOT ENLARGE HOLE, FOR BOLT SIZE SEE 7/S2 7/S2 SHORE (E) TRUSS AT 7'-0" MAX (E) MEMBER TO REMAIN FOR LOCATION SEE L2x2x1/8 FOR LOCATION SEE 7/S2 REMOVE (E) PIN AND REUSE TO CONNECT NEW MEMBER IF NECESSARY REPLACE WITH BOLT OF EQUAL SIZE DO NOT ENLARGE HOLE, FOR BOLT SIZE SEE 7/S2 7/S2 1 " MI NSHORE (E) TRUSS AT 7'-0" MAX (E) MEMBER TO REMAIN FOR LOCATION SEE L2x2x3/16 FOR LOCATION SEE 7/S2 REMOVE (E) PIN AND REUSE TO CONNECT NEW MEMBER IF NECESSARY REPLACE WITH BOLT OF EQUAL SIZE DO NOT ENLARGE HOLE, FOR BOLT SIZE SEE 7/S2 7/S2 1/8 3 1/8 3TYP 3/16 2 1/2TYP PL1/4 TYP CUT (E) DIAGONAL AT INTERSECTION NOTCH TO FIT GUSSET PL 8"6"SHORE (E) TRUSS AT 7'-0" MAX S2 9 TYP (E) MEMBER TO REMAIN FOR LOCATION SEE (2) 2x4 DF#2 W/ (3) 1/2" Ø BOLTS EACH END FOR LOCATION SEE 7/S2 REMOVE (E) PIN AND REUSE TO CONNECT NEW MEMBER IF NECESSARY REPLACE WITH BOLT OF EQUAL SIZE DO NOT ENLARGE HOLE, FOR BOLT SIZE SEE 7/S2 7/S2 1/8 3 1/8 3TYP PL1/4 CUT (E) DIAGONAL AT INTERSECTION NOTCH TO FIT GUSSET PL 3 1 / 2 " 2 " 2 " 1 " SHORE (E) TRUSS AT 7'-0" MAX S2 9 TYP 1'-0"1'-3" (E) TRUSS 362T250-43 W/ (2) #8 SCREWS @ EA TRUSS 150U50-43 BRIDGING PERPENDICULAR PARALLEL DO NOT SCREW TRACK TO STUDS CLIP ANGLE AT EACH STUD W/ (2) #8 SCREWS TO BRIDGING AND STUD 362S162-33 @ 24" OC CLIP ANGLE W/ (2) #8 SCREWS TO BOTTOM CHORD AND STUD 1 1/2"1 1/2"DETAIL IS FOR SLIP TRACK CONNECTION TO (E) TRUSS ONLY FOR ADDITIONAL METAL STUD SPECIFICATIONS SEE INTERIOR REMODEL DESIGN TEAM DRAWINGS VERIFY BRIDGING AT 4'-0" OC MIN ± 1/2 " M A X± 1/2" MAX OF L2x2 OF 2x4 EQ1/2" 1 1/2 "SHEET TITLE: SHEET NUMBER: © MARTIN/MARTIN 2017DESIGNERS: DATE PRINTED: MM JOB #: PRINCIPAL: EOR: PROJECT MANAGER: Martin/Martin, Inc. considers that design data is only in its final form on plotted drawings with original signatures and professional certification being visibly present on the drawings. Data supplied via computer generated format does not contain this approval or certification. The receiver of electronically transmitted drawings is responsible for verifying the information contained within the electronic data against the recorded or approved documents.The use of electronically transmitted drawings is considered to be at your own risk. Martin/Martin, Inc. assumes no responsibility for any claims or damages resulting from your use of this information. Electronic information is provided for the convenience of the recipient only. The recipient of this file agrees that the information may not be transferred to any other party.PROJECT NO: DATE:5/19/2017 10:47:01 AMC:\Proj\MS17.0085-Doubletree Vail RoofRepair-RS17_seanm.rvtS2DOUBLETREE VAILBALLROOM ROOF REPAIR2211 N FRONTAGE RDWEST VAIL, CO 81657DETAILSKM SMEJMS17.0085.S.01MS17.0085.S.01 02/13/17 SMNO SCALE 7 TRUSS KEYNOTE SCHEDULE 1" = 1'-0" 2 OPTION #1 1" = 1'-0" 3 OPTION #2 1" = 1'-0" 5 OPTION #3 1" = 1'-0" 6 OPTION #4 1" = 1'-0" 8 TYP SLIP TRACK CONNECTION 1 1/2" = 1'-0"9 ALLOWABLE OFFSET @ GUSSET PLATE NO ISSUE DATE 5/19/2017 01/11/18 01/11/18 01/11/18 01/11/18 GUESTROOMS LOUNGE/ LOBBYRESTAURANT POOL PARKING PARKING N FRONTAG E RO AD ENTRY 1 A 2 3 4 5 6 A B C D E13 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.B C D EDRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ®12/1/2017 3:08:44 PMTITLE SHEET THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/04/2017 - CONSTRUCTION DOCUMENTS T001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 2211 N FRONTAGE RD, VAIL, COLORADO 81657 BASKERVILL 101 S. 15TH ST., SUITE 200 (23219) P.O. BOX 400 RICHMOND, VA 23218-0400 PHONE: (804) 343-1010 FAX: (804) 343-0909 CONTACT: MARK DAVIDSON THE WIDEWATERS GROUP 5786 WIDEWATERS PARKWAY SYRACUSE, NY 13214 PHONE: (315) 445-2424 THE WIDEWATERS GROUP OWNER / CLIENT: ARCHITECT, INTERIOR DESIGNER & MEP ENGINEERS: DRAWING INDEX SHEET NO SHEET TITLE REV NO REV DATE A448b ENLARGED GUESTROOM PLANS - KCCON LOFT (ROOM 501) 9 7/21/2017 A448c ENLARGED GUESTROOM PLANS - KCCON LOFT (ROOM 501) 9 7/21/2017 A449 ENLARGED GUESTROOM PLANS - K2 (ROOM 202) 9 7/21/2017 A450 ENLARGED GUESTROOM PLANS - K3 (ROOM 206) 9 7/21/2017 A451a ENLARGED GUESTROOM PLANS - DKL (ROOM 436) 10 9/15/2017 A451b ENLARGED GUESTROOM PLANS - DKL LOFT (ROOM 536) 10 9/15/2017 A451c ENLARGED GUESTROOM PLANS - DKL LOFT (ROOM 536) 9 7/21/2017 A452 ENLARGED GUESTROOM PLANS - K4L (ROOM 411) 9 7/21/2017 A453 ENLARGED GUESTROOM PLANS - KEXL (ROOM 402) 9 7/21/2017 A500 GUESTROOM MILLWORK DETAILS 9 7/21/2017 A501 GUESTROOM MILLWORK DETAILS & CONDO STAIR DETAILS 9 7/21/2017 A502 FIREPLACE DETAILS 9 7/21/2017 A504 PORTE COCHERE - ADDITIONAL DETAILS 10 9/15/2017 A601 MILLWORK - COFFEE BAR 13 12/01/2017 A602 MILLWORK - MADE MARKET 13 12/01/2017 A604 MILLWORK - BALLROOM, MEETING ROOM, BOARD ROOM, EMPLOYEE BREAKROOM, RESTROOM, AND GUEST LAUNDRY 9 7/21/2017 A605 MILLWORK - FRONT DESK 10 9/15/2017 A605b SCREEN PANELS - FRONT DESK & BAR A606 MILLWORK - LOBBY BAR 10 9/15/2017 A607 MILLWORK - LOBBY BAR 10 9/15/2017 P001 SCHEDULES, LEGEND & DETAILS 9 7/21/2017 P101 1st FLOOR - DEMOLITION 13 12/01/2017 P111 1st FLOOR - NEW WORK 10 9/15/2017 P112 2nd FLOOR PLAN 1 08/25/2016 P113 3rd FLOOR PLAN 1 08/25/2016 P114 4th FLOOR PLAN 1 08/25/2016 P115 5th FLOOR PLAN P401 ENLARGED PUBLIC SPACE PLANS 1 08/25/2016 P402 ENLARGED BAR & MADE MARKET PLAN 13 12/01/2017 P403 ENLARGED KITCHEN PLANS 13 12/01/2017 P410 ENLARGED GUESTROOM DETAILS 1 08/25/2016 P411 ENLARGED GUESTROOM DETAILS 9 7/21/2017 P600 RISER DIAGRAMS 1 08/25/2016 M001 LEGEND, DETAILS & SCHEDULES 10 9/15/2017 M002 DETAILS AND SCHEDULES 10 9/15/2017 M101 1ST FLOOR DEMOLITION 10 9/15/2017 M102 2ND FLOOR DEMOLITION 10 9/15/2017 M201 1ST FLOOR DUCTWORK PLAN 13 12/01/2017 M202 1ST FLOOR LOBBY, BATHROOM, AND 2ND FLOOR DUCTWORK PLAN 10 9/15/2017 M203 KITCHEN DUCTWORK PLAN 13 12/01/2017 M301 1ST FLOOR PIPING PLAN 1 08/25/2016 M701 UNIT CONTROLS 10 9/15/2017 E001 LEGEND, SPECS, LIGHTING FIXTURE SCHEDULE 10 9/15/2017 E101 DEMOLITION PLAN - 1st FLOOR 10 9/15/2017 E102 2nd AND 3rd FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLANS 1 08/25/2016 E104 4th AND 5th FLOOR GUESTROOM CORRIDOR LIGHTING DEMOLITION PLAN 1 08/25/2016 E111 1st FLOOR PLAN - LIGHTING 10 9/15/2017 E121 1st FLOOR PLAN - POWER AND COMMUNICATIONS 10 9/15/2017 E122 2nd, 3rd AND 4th TYPICAL FLOOR PLANS - POWER AND LIGHTING 1 08/25/2016 E131 1st FLOOR PLAN - MECHANICAL POWER 10 9/15/2017 E141 1st FLOOR PLAN - FIRE ALARM 10 9/15/2017 E401 COMPACTOR ENCLOSURE LIGHTING AND POWER 9 7/21/2017 E401a ENLARGED FLOOR PLAN - LOBBY/ LOUNGE / BAR LIGHTING 10 9/15/2017 E401b ENLARGED FLOOR PLAN - LOBBY / LOUNGE / BAR POWER 4 11/07/2016 E402 ENLARGED PLANS - SPA / THERAPY AND PUBLIC RESTROOMS 1 08/25/2016 E403 ENLARGED PLANS - MEETING ROOMS 9 7/21/2017 E404 ENLARGED PLANS - BACK OF HOUSE 4 11/07/2016 E405 ENLARGED PLANS - BALLROOM 9 7/21/2017 E406 ENLARGED PLANS - FITNESS, GUEST LAUNDRY, AND MADE MARKET9 7/21/2017 E430 ENLARGED GUESTROOM PLANS 9 7/21/2017 E431 ENLARGED GUESTROOM PLANS 9 7/21/2017 E432 ENLARGED GUESTROOM PLANS 9 7/21/2017 E433 ENLARGED GUESTROOM PLANS 9 7/21/2017 E434 ENLARGED GUESTROOM PLANS 9 7/21/2017 K100 OVERALL FOODSERVICE EQUIPMENT LAYOUT 13 12/01/2017 K101 ENLARGED BAR & MADE MARKET FOOD SERVICE EQUIPMENT LAYOUT K102 ENLARGED KITCHEN FOOD SERVICE EQUIPMENT PLAN 13 12/01/2017 K201 ENLARGED BAR & MADE MARKET PLUMBING ROUGH-IN PLAN K202 ENLARGED KITCHEN PLUMBING ROUGH-IN PLAN 13 12/01/2017 K250 KITCHEN EQUIPMENT SCHEDULE 13 12/01/2017 K301 ENLARGED BAR & MADE MARKET ELECTRICAL ROUGH-IN PLAN K302 ENLARGED KITCHEN ELECTRICAL ROUGH IN PLAN 13 12/01/2017 K401 ENLARGED BAR & MADE MARKET SPECIAL CONDITION PLAN K450 EXHAUST HOOD SHOP DRAWINGS - A 13 12/01/2017 K451 EXHAUST HOOD SHOP DRAWINGS - B 13 12/01/2017 K550 BAR AND MADE MARKET ELEVATIONS 13 12/01/2017 SHEET NO SHEET TITLE REV NO REV DATE T001 TITLE SHEET 13 12/01/2017 G001 BUILDING & CODE SUMMARY 10 9/15/2017 G002 LIFE SAFETY LEGEND & LIFE SAFETY PLAN - 1ST FLOOR 13 12/01/2017 G003 LIFE SAFETY PLANS - 2ND & 3RD FLOORS G004 LIFE SAFETY PLANS - 4TH FLOOR & LOFT G005 UL DETAILS G006 UL DETAILS D111 DEMOLITION PLAN - 1ST FLOOR 13 12/01/2017 D112 DEMOLITION PLAN - 2ND & 3RD FLOORS 3 10/07/2016 D113 DEMOLITION PLAN - 4TH FLOOR & LOFT 9 7/21/2017 D121 DEMOLITION PLAN - 1ST FLOOR REFLECTED CEILING 10 9/15/2017 D122 DEMOLITION PLAN - 2ND & 3RD FLOORS REFLECTED CEILING 1 08/25/2016 D123 DEMOLITION PLAN - 4TH FLOOR & LOFT REFLECTED CEILING 1 08/25/2016 D202 DEMOLITION PLAN - EXTERIOR ELEVATION - DEMOLITION 10 9/15/2017 S001 GENERAL NOTES 10 9/15/2017 S002 QUALITY ASSURANCE 10 9/15/2017 S100 1ST FLOOR KEYPLAN 1 08/25/2016 S101 PLAN VIEWS 10 9/15/2017 S102 BALLROOM / MEETING ROOM PART PLAN 1 08/25/2016 S103 LOBBY PART PLAN 1 08/25/2016 S201 SECTIONS AND DETAILS 1 08/25/2016 S202 SECTIONS AND DETAILS 1 08/25/2016 S203 SECTIONS AND DETAILS 1 08/25/2016 S301 FLOOR DETAILS S601 ROOF DETAILS S602 ROOF DETAILS A001 GENERAL DRAWING STANDARDS & NOTES A002a GENERAL ACCESSIBILITY STANDARDS 2 09/19/2016 A002b ACCESSIBLE & STANDARD SHOWER & TUB ENLARGED PLANS & ELEVATIONS 2 09/19/2016 A003 HEARING IMPAIRED ROOM TYPES - PLANS, ELEVATION & LEGEND A010 ROOM SCHEDULE AND MATRIX 10 9/15/2017 A020 PARTITION TYPES, DETAILS, AND STANDARDS 10 9/15/2017 A030 DOOR & WINDOW, FRAME AND HARDWARE TYPES & SCHEDULES 13 12/01/2017 A040 INTERIOR STOREFRONT DETAILS 9 7/21/2017 A041 EXTERIOR STOREFRONT DETAILS 1 08/25/2016 A050 FINISHES 10 9/15/2017 A101 SITE - PLAN A111 OVERALL PLAN - 1ST FLOOR 13 12/01/2017 A112 OVERALL PLAN - 2ND & 3RD FLOORS 3 10/07/2016 A113 OVERALL PLAN - 4TH FLOOR & LOFT 9 7/21/2017 A114 TYPICAL CORRIDOR PLANS 3 10/07/2016 A121 REFLECTED CEILING PLAN - 1ST FLOOR PLAN 13 12/01/2017 A122 REFLECTED CEILING PLAN - 2ND & 3RD FLOORS 9 7/21/2017 A123 REFLECTED CEILING PLAN - 4TH FLOOR UPPER LEVEL/LOFT 9 7/21/2017 A131 1ST FLOOR - FINISH PLAN 10 9/15/2017 A141 1ST FLOOR - FF&E PLAN 9 7/21/2017 A301 EXTERIOR ELEVATION - CONSTRUCTION 10 9/15/2017 A302 EXTERIOR ELEVATIONS - CONSTRUCTION 10 9/15/2017 A401a ENLARGED FLOOR PLAN - LOBBY/LOUNGE/BAR/KITCHEN 13 12/01/2017 A401b ENLARGED FURNITURE PLAN - LOBBY/LOUNGE/BAR 10 9/15/2017 A401c ENLARGED REFLECTED CEILING PLAN - LOBBY/LOUNGE/BAR 13 12/01/2017 A401d INTERIOR ELEVATIONS - LOBBY/LOUNGE/BAR 13 12/01/2017 A402 ENLARGED PLANS - MASSAGE/ SPA 2 09/19/2016 A403 ENLARGED PLANS - MEETING ROOMS 9 7/21/2017 A404 ENLARGED PLANS - BACK OF HOUSE 9 7/21/2017 A405 ENLARGED PLANS - BALLROOM 10 9/15/2017 A406 ENLARGED PLANS - FITNESS, GUEST LAUNDRY, AND MADE MARKET10 9/15/2017 A410 ENLARGED TOILET PLANS 9 7/21/2017 A430 ENLARGED ACCESSIBLE GUESTROOM PLANS - KAL (ROOM 204) 9 7/21/2017 A431 ENLARGED ACCESSIBLE GUESTROOM PLANS - KAR (ROOM 203) 9 7/21/2017 A432 ENLARGED ACCESSIBLE GUESTROOM PLANS - KARI (ROOM 237) 9 7/21/2017 A434 ENLARGED ACCESSIBLE GUESTROOM PLANS - QQARI (ROOM 235) 9 7/21/2017 A435 ENLARGED ACCESSIBLE GUESTROOM PLANS - QA (ROOM 306) 9 7/21/2017 A436 ENLARGED ACCESSIBLE GUESTROOM PLANS - QA (ROOM 406) 9 7/21/2017 A437a ENLARGED ACCESSIBLE GUESTROOM PLANS - KCONAL (ROOM 424)9 7/21/2017 A437b ENLARGED GUESTROOM PLANS - KCONL LOFT (ROOM 524) 9 7/21/2017 A441 ENLARGED GUESTROOM PLANS - K1L (ROOM 208) 9 7/21/2017 A442 ENLARGED GUESTROOM PLANS - QQ1L (RM 205) 9 7/21/2017 A443 ENLARGED GUESTROOM PLANS - KS (ROOM 301) 9 7/21/2017 A444 ENLARGED GUESTROOM PLANS - KEX (ROOM 439) 9 7/21/2017 A445a ENLARGED GUESTROOM PLANS - KKCON (ROOM 405) 9 7/21/2017 A445b ENLARGED GUESTROOM PLANS - KKCON LOFT (ROOM 505) 9 7/21/2017 A446a ENLARGED GUESTROOM PLANS - KCONR (ROOM 403) 9 7/21/2017 A446b ENLARGED GUESTROOM PLANS - KCONR LOFT (ROOM 503) 9 7/21/2017 A447 ENLARGED GUESTROOM PLANS - Q1 (ROOM 438) 9 7/21/2017 A448a ENLARGED GUESTROOM PLANS - KCCON (ROOM 401) 9 7/21/2017 KEY PLAN VICINITY MAP CODE DATA SUMMARY (NEW WORK) DESCRIPTION OF WORK USE GROUP: R-1 RESIDENTIAL (HOTEL), NO CHANGE CONSTRUCTION TYPE: EXISTING, NO CHANGE FULLY SPRINKLERED: YES, EXISTING, NO CHANGE HEIGHT OF BUILDING: 58'-0" +/- (4 STORIES EXISTING), NO CHANGE HIGH RISE: NO FIRE ALARM SYSTEM: YES, EXISTING, NO CHANGE APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2014 NATIONAL ELECTRIC CODE 2015 AMMENDMENTS LOCATED IN ORDINANCE NO. 14, SERIES 2015 2009 ICC/ ANSI A117.1 REFER TO G001 FOR EXPANDED CODE SUMMARY SITE THE CONVERSION OF EXISTING HOLIDAY INN GUESTROOMS AND PUBLIC SPACES INTO DOUBLETREE BY HILTON BRAND HOTEL. WORK SHALL INCLUDE ALL DEMOLITION, PATCH, REPAIR, NEW CONSTRUCTION, ETC. INDICATED AND NECESSARY TO COMPLETE INTEROR DOUBLETREE BRAND CONVERSION AS INDICATED IN CONSTRUCTION DOCUMENTS. ALL REQUIRED EXITS ARE TO REMAIN OPEN DURING DURATION OF WORK. 108/25/2016Revision 1 209/19/2016CCD-002 411/07/2016ASI #2 7 3/28/2017RFI 71 Response 9 7/21/2017CCD-005 109/15/2017CCD-006 1312/01/2017CCD-09 13 12/05/2017 01/11/18