Loading...
HomeMy WebLinkAboutB17-0010_A6.04D_1502813460.pdfFD F FP T TV S CO 1.51.5 1.11 1.3 1.6 1.10 A6.04D 7 4 6 A6.04D 5 A6.04D 8 22.2 22.3 1 2 10 A6.04D 9 A6.04D 11 A6.04D 22.1 8.3 7' - 5" 7' - 5" SPECIFIED SHOWER PAN. RE: INT. DESIGN SPECS CONT. SEALANT & BACKER ROD. SPECIFIED TILE & SETTING BED. RE: INT. DESIGN SPECS NEW 5/8" TYPE X GEORGIA PACIFIC DENS SHIELD TILE BACKER BOARD EXISTING PARTITION. RE: PARTITION SCHEDULE SPECIFIED SHOWER PAN. RE: INT. DESIGN SPECS CONT. SEALANT & BACKER ROD. SPECIFIED TILE & SETTING BED. RE: INT. DESIGN SPECS NEW 5/8" TYPE X GEORGIA PACIFIC DENS SHIELD TILE BACKER BOARD EXISTING PARTITION. RE: PARTITION SCHEDULE 1 HR-RATED 5/8" TYPE X GA. PACIFIC DENS SHIELD TILE BACKER BD, BOX OUT AROUND SHOWER VALVE, FIRE CAULK AS REQUIRED NEW SHOWER TRIM & VALVE, RE: PLUMBING FIXTURE SCHEDULE # PRIMARY FRAMING NOM WIDTH RATING DESIGN COMMENTS 1 3 5/8" MTL STUD 5" 1HR UL DESIGN U442 EXISTING 1 # PRIMARY FRAMING NOM WIDTH RATING DESIGN COMMENTS 2 3 5/8" MTL STUD 9" 1HR UL DESIGN U442 EXISTING 2 WALL DUPLEX OUTLET WALL QUADRUPLEX OUTLET FIREPLACE CONTROL / NATURAL GAS TELEPHONE CONNECTION THERMOSTAT SCONCE SWITCH SHOWER HEAD FIRE ALARM TELEVISION DATA CONNECTION COAT HOOKS WALL DUPLEX OUTLET GFCI MECH / ELEC PANEL / WALL UNIT RECESSED CAN LIGHT FIXTURE EXHAUST FAN SPRINKLER HEAD EXIT SIGNAGE SMOKE/CO DETECTOR PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 4/3/2017 5:28:15 PM As indicated VAIL MARRIOTT 715 W Lionshead Cir, Vail, CO 81657 16-26 Author Checker 04/18/2017 BATHROOM PERMIT SET STD BATH CONV. PLANS A6.04D Approver 1/2" = 1'-0" 1 Std - Shwr Conv. Demo Plan 1/2" = 1'-0" 5 Std Bath Shwr. Conv. Elev. D3 1/2" = 1'-0" 2 Std - Shwr Conv. Construction Plan 1/2" = 1'-0" 8 Std Bath Shwr. Conv. D2 1/2" = 1'-0" 3 Std - Bath Demo RCP 1/2" = 1'-0" 4 Std Bath Elevation A 1/2" = 1'-0" 6 Std Bath Elevation B 1/2" = 1'-0" 7 Std Bath Elevation C 3" = 1'-0" 9 SHOWER TILE SURROUND / DEMISING WALL DETAIL GA WP 5070 - 1 HR 3" = 1'-0" 10 SHOWER TILE SURROUND / DEMISING WALL DETAIL - NOT RATED 3" = 1'-0" 11 FIRE RATING @ SHOWER VALVE UL DESIGN U442 GA FILE WP 5070 FLAGNOTES PER SHEET 1.3 REMOVE EXISTING WALL & FLOOR TILE, PROVIDE NEW CEMENT BOARD SUBSTRATE @ WALL TILE. 1.5 REMOVE EXISTING WALL COVERING & PREP TO RECEIVE NEW WALL COVERING, TYP. 1.6 REMOVE EXISTING WALL SCONCES THROUGHOUT, TYP. 1.10 REMOVE EXISTING VANITY, COUNTERTOP, BACKSPLASH, & PLUMBING IN THEIR ENTIRETY; CAP PLUMBING AT WALL / COORDINATE W/ NEW FIXTURES & VANITY. RE: PLUMBING & PLUMBING FIXTURE SCHEDULE ON SHEET G5.01. 1.11 REMOVE EXISTING BATH PLUMBING FIXTURES & FILLER VALVE PREP TO RECEIVE NEW TUB DIVERTER & SPOUT. 8.3 NEW FRAMELESS GLASS BYPASS SLIDING DOOR. 22.1 NEW SHOWER PAN. RE: PLUMBING FIXTURE SCHEDULE; & RELOCATE DRAIN AS REQUIRED TO COORDINATE. 22.2 NEW PLUMBING FIXTURES & VALVES & ACCESSORIES AT TUB/SHOWER. AS PER FURNITURE PLAN. 22.3 NEW SINK & LAVATORY FIXTURES TO REPLACE EXISTING VANITY. RE: FF&E PACKAGE. GENERAL PLAN NOTES 1. SCONCES MOUNTED AT 70", U.N.O. 2. SWITCHES MOUNTED AT 44", U.N.O. 3. COAT HOOKS MOUNTED AT 70", U.N,O. UNIT PLAN NOTES 1. EXISTING WALLS & WALL FINISHES TO REMAIN, U.N.O. 2. ALL EXISTING CEILINGS TO REMAIN, U.N.O. 3. ALL EXISTING DOORS, TRIM, & BASE TO REMAIN. U.N.O. 4. REMOVE EXISTING SIGNAGE / WAYFINDING THROUGHOUT, TYP. 5. REMOVE ALL EXISTING TOILET ACCESSORIES, U.N.O. 6. REMOVE & PROTECT EXISTING MECHANICAL ELECTRICAL LIFE SAFETY DEVICES & COVERS DURING RENOVATION FOR RE-INSTALLATION, TYP. 7. EXISTING CEILING CAN LIGHTS TO REMAIN TYP. 8. ANY DEMOLITION AT FIRE RESISTANCE RATED WALLS TO BE TEMPORARILY FIRE-CAULKED/ RATED AS REQUIRED TO NOT COMPROMISE FIRE SEPARATION 9. PROVIDE BLOCKING AS REQUIRED FOR ALL TOILET ACCESSORIES & WALL - HUNG ITEMS 10. EXISTING WALL / DOOR STOPS TO REMAIN, TYP; REMOVE & REPLACE AS REQUIRED FLOOR PLAN SYMBOLS RCP SYMBOLS 08/15/17