Loading...
HomeMy WebLinkAboutB17-0010_G1.01_1502813460.pdf1 A5.01 1 A5.11 SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER BUILDING SECTION IDENTIFICATION WALL SECTION IDENTIFICATION 1 A9.01 SHEET NUMBER DRAWING NUMBER DETAIL IDENTIFICATION INTERIOR ELEVATION IDENTIFICATION 1 A6.01 SHEET NUMBER DRAWING NUMBER ENLARGED DETAIL IDENTIFICATION AREA OF DRAWING TO BE ENLARGED SECTION MATERIAL GRAPHICS 23A 76H PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE IDENTIFICATION ACOUSTIC PARTITION TYPE IDENTIFICATION DOOR SIZE DOOR IDENTIFICATION ROOM NAME 314 876.00 SF ROOM NUMBER ROOM/SPACE/AREA IDENTIFICATION ROOM NAME ROOM AREA A 1 COLUMN LETTER COLUMN LETTER COLUMN REFERENCE GUIDE STRUCTURAL GRID ELEVATION LEVEL NAME BATT INSULATION CONCRETE UNDISTURBED OR COMPACTED EARTH POROUS FILL (GRAVEL) STEEL ALUMINUM MASONRY - BRICK MASONRY - CONCRETE BLOCK RIDGID INSULATION GYPSUM PLASTER PLYWOOD FINISH WOOD EXTERIOR ELEVATION IDENTIFICATION 1 A4.01 A7.01 99 99 99 99 WINDOW SIZE SHEET NUMBER DRAWING NUMBER ? WINDOW IDENTIFICATION KEYNOTE IDENTIFICATION NOTE NUMBER 001 ASI REVISION IDENTIFICATION REVISION NUMBER REVISION DESCRIPTION Name Elevation ELEVATION DATUM IDENTIFICATION B1 3068 TRUE NORTH PROJECT NORTH SCALE: 1" = 300'-0" ZONING: OCCUPANCY: CONSTRUCTION TYPE(S): SPRINKLERED: ALLOWABLE SQUARE FOOTAGE: ALLOWABLE BUILDING HEIGHT: BUILDING CONSTRUCTION: EXTERIOR BEARING WALLS: INTERIOR BEARING WALLS: EXTERIOR NON-BEARING WALLS: STRUCTURAL FRAME: FLOORS - CEILINGS/ROOFS: ROOFS - CEILINGS/ROOFS: SHAFT ENCLOSURES (4+ STORIES): STAIRWAY CONSTRUCTION: GROSS BUILDING AREA: BUILDING HEIGHT: NUMBER OF STORIES: ESTIMATED OCCUPANT LOAD: PLUMBING FIXTURE COUNT: BUILDING CODES: LOCAL AMENDMENTS: LHMU-1 (EXISTING) R-1 TYPE II FR (UBC - EXISTING) YES EXISTING EXISTING TYPE II FR (UBC - EXISTING) 0 0 0 APPROX. - 75'-0" 7 EXISTING N/A 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2014 NATIONAL ELECTRIC CODE N/A BUILDING & CODE INFORMATION 2HR COLS: UL X528; BMS UL N501 OR N502 2HR UL J948 2HR UL J503 2HR 2HR PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 4/3/2017 5:28:16 PM As indicated VAIL MARRIOTT 715 W Lionshead Cir, Vail, CO 81657 16-26 Author Checker 04/18/2017 BATHROOM PERMIT SET COVER SHEET G1.01 Approver ABBREVIATIONS SD SOAP DISPENSER SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SSK SERVICE SINK SS STAINLESS STEEL SR SINK RECEPTACLE SCHED SCHEDULE SEC SECTION SHWR SHOWER SHT SHEET SHTG SHEATHING SIM SIMILAR SPECS SPECIFICATION(S) SQ SQUARE SF SQUARE FEET STL STEEL STA STATION STD STANDARD STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM SOFF SOFFIT SPKR SPEAKER SPKL SPRINKLER T&B TOP AND BOTTOM T TREAD T&G TONGUE AND GROOVE TB TOWEL BAR TO TOP OF TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TV TELEVISION TELE TELEPHONE THK THICK or THICKNESS THLD THRESHOLD TYP TYPICAL TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS TBC TOP OF BACK OF CURB TS TUBE STEEL TOW TOP OF WALL TOS TOP OF STEEL TOC TOP OF CONCRETE THERM THERMOSTAT USGS U.S. GEOLOGICAL SURVEY UL UNDERWRITER'S LABORATORY UON UNLESS OTHERWISE NOTED UOS UNLESS OTHERWISE SPECIFIED UNFIN UNFINISHED UR. URINAL V VOLT VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VTR VENT THROUGH ROOF VWC VINYL WALL COVERING VERT VERTICAL VEST VESTIBULE VIN VINYL or SHEET VINYL VAR VARY or VARIES VIF VERIFY IN FIELD VER VERIFY VENT VENTILATION VOL VOLUME WD WOOD W WEST or WIDE W/C WATER CLOSET WPT WORKING POINT W/R WATER RESISTANT WWF WELDED WIRE FABRIC W/ WITH W/O WITHOUT WF. WIDE FLANGE or WOOD FLOORING WDO WINDOW WP WATERPROOF(ING) WSCT WAINSCOT WC WALL COVERING WT WEIGHT W.O. WHERE OCCURS WGL WIRE GLASS YD YARD GRT GROUT GI GALVANIZED IRON HC HOLLOW CORE or HANDICAPPED HM HOLLOW METAL HDR HEADER HDWR HARDWARE HT HEIGHT HORIZ HORIZONTAL HR HOUR HVAC HEATING, VENTILATION and AIR CONDITIONING HB HOSE BIB HDAS HEADED DEFORMED ANCHOR STUD HAS HEADED ANCHOR STUD HWY HIGHWAY HWH HOT WATER HEATER HW HOT WATER HTR HEATER IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR ID INSIDE DIAMETER IN INCH(ES) INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INCAND INCANDESCENT INV INVERT INTMED INTERMEDIATE INCL INCLUD(ED) JST JOIST JT JOINT JC JANITOR CLOSET KD KNOCKDOWN KP KICK PLATE KIT KITCHEN KO KNOCKOUT LH LEFT HAND LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LKR LOCKER LT LIGHT LTL LINTEL LVR LOUVER LDR LEADER LP LIGHTING PANEL or LIGHT PROOF MO MASONRY OPENING MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEP MECHANICAL, ELECTRICAL and PLUMBING MTL METAL MFR MANUFACTURER MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MEMB MEMBRANE MTD MOUNT(ED) MUL MULLION MED MEDIUM MAG MAGNETIC MACH MACHINERY MM MILLIMETERS MH MANHOLE MEZZ MEZZANINE MB MOISTURE BARRIER N NORTH (N) NEW NIC NOT IN CONTRACT NTS NOT TO SCALE NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OTO OUTSIDE-TO-OUTSIDE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OF OUTSIDE FACE PC PRECAST PAC PREVIOUSLY AWARDED CONTRACT P/L PROPERTY LINE PLAM PLASTIC LAMINATE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PVC POLYVINYL CHLORIDE PLYWD PLYWOOD PREFAB PREFABRICATED PL PLATE PLAS PLASTER PNL PANEL P PAINT(ED) PR PAIR or PROPOSAL REQUEST PROJ PROJECT PTD PAPER TOWEL DISPENSER PTN PARTITION PVMT PAVEMENT PRESTR PRESTRESSED PBO PROVIDED BY OTHERS PAR PARALLEL PREFIN PREFINISHED POL POLISHED PLBG PLUMBING PKG PARKING PERIM PERIMETER PERF PERFORATED PTR PAPER TOWEL RECEPTACLE PRIM PRIMARY PT POINT OF TANGENCY QTY QUANTITY QT QUARRY TILE (R) REMOVE R RISER RD ROOF DRAIN or ROAD RL RAIN LEADER RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN RWC RAIN WATER CONDUCTOR RAD RADIUS RE REFER TO or REFERENCE REINF REINFORCED REC RECESS(ED) REF REFRIGERATOR or REFRIGERATED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S) RFG ROOFING RFL REFLECTED RM ROOM ROW RIGHT OF WAY RBS RUBBER BASE STRAIGHT RBC RUBBER BASE COVE RB RUBBER BASE RH RIGHT HAND RF RESILIENT FLOORING RECPT RECEPTACLE RBT RUBBER TILE RVS REVERSE (SIDE) RPM REVOLUTIONS PER MINUTE SPRT SUPPORT S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER & AND < ANGLE @ AT # POUND(S) or NUMBER AB ANCHOR BOLT AFF ABOVE FINISHED FLOOR ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AGG AGGREGATE AHU AIR HANDLING UNIT ALUM ALUMINUM ALT ALTERNATE AVE AVENUE ARCH ARCHITECTURAL ASPH ASPHALT AUTO AUTOMATIC AD AREA DRAIN or ACCESS DOOR ANOD ANODIZED APPROX APPROXIMATE A/V AUDIO/VISUAL AVG AVERAGE AWP ACOUSTICAL WALL PANEL B.O.F. BY OWNER, FUTURE BD BOARD B.O. BY OWNER BLDG BUILDING BIT BITUMINOUS BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT B BASE CJ CONTROL JOINT CL COLUMN LINE CONF CONFERENCE C.L. CENTERLINE CIRC CIRCUMFERENCE CAB CABINET C CAULKING CCD CONSTRUCTION CHANGE DIRECTIVE CFL COUNTERFLASHING CG CORNER GUARD CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT CT CERAMIC TILE CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CK CORK TILE CLG CEILING CLOS CLOSET CLR CLEAR CTR COUNTER COL COLUMN CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CIP CAST IN PLACE CONN CONNECTION CATV CABLE TELEVISION CCTV CLOSED CIRCUIT TELEVISION CU CUBIC CY CUBIC YARD DEG DEGREE DAMP DAMPROOFING DF DRINKING FOUNTAIN DBL DOUBLE DEPT DEPARTMENT DTL DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DISP DISPENSER DR DOOR DS DOWNSPOUT DWG DRAWING DWR DRAWER DIV DIVISION DIAG DIAGONAL DEMO DEMOLISH or DEMOLITION EJ EXPANSION JOINT (E) EXISTING EB EXPANSION BOLT E EAST ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EWC ELECTRIC WATER COOLER EA EACH EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT EXT EXTERIOR ES EACH SIDE EWH ELECTRIC WATER HEATER EW EACH WAY EST ESTIMATE FAC FIRE ALARM CABINET FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S) FD FLOOR DRAIN or FIRE DAMPER FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FFL FINISHED FLOOR LINE FHC FIRE HOSE CABINET FR FIRE RESISTIVE or FIRE RATED FDN FOUNDATION FIN FINISH(ED) FIXT FIXTURE FLG FLASHING FLR FLOOR(ING) FLUOR FLUORESCENT FRT FIRE RETARDANT TREATED FRP FIBERGLASS REINFORCED PANEL(ING) FT FOOT (FEET) FTG FOOTING FURR FURRED or FURRING FUT FUTURE F FARENHEIT FVC FIRE VALVE CABINET FHMS FLAT HEAD MACHINE SCREW FH FIRE HYDRANT FF FINISHED FLOOR FURN FURNISH(ED) FOM FACE OF MASONRY FOF FACE OF FINISH FOS FACE OF STUD FOC FACE OF CONCRETE FHWS FLAT HEAD WOOD SCREW FHV FIRE HOSE VALVE GWB GYPSUM WALLBOARD GC GENERAL CONTRACTOR GB GRAB BAR GYP. BD. GYPSUM BOARD GCMU GLAZED CONCRETE MASONRY UNIT(S) GA GAUGE GR GRADE GL GLASS or GLAZING GND GROUND GALV GALVANIZED GYP GYPSUM GT GLASS TILE GRAPHIC STANDARDS Sheet # Sheet Name 04/03/17 GENERAL G1.01 COVER SHEET X G2.03 LEVEL 3 OVERALL PLANS X G2.05 LEVEL 5 OVERALL PLANS X ARCHITECTURE A6.04D STD BATH CONV. PLANS X A6.16D SK B BATH X VICINITY MAP VAIL MARRIOTT BATHROOM PERMIT SET 04/18/2017 715 W Lionshead Cir, Vail, CO 81657 OWNER DIAMOND ROCK HOSPITALITY GROUP 3 BETHESDA METRO CENTER SUITE 1500 BETHESDA, MD 20814 POC:SCOTT K. HAMMONS P:240.744.1185 SCOTT.HAMMONS@DRHC.COM INTERIOR DESIGNER SIMEONE DEARY DESIGN GROUP 605 NORTH MICHIGAN AVENUE, SUITE 350 CHICAGO, ILLINOIS 60611 POC:SARA TALLEUX P:312.237.4913 SARA.TALLEUX@SIMEONEDEARY.COM ARCHITECT NEO STUDIO 3560 Walnut St Denver, CO 80205 POC:KARLIN VAESSEN P:303.758.3800 KARLIN@NEOSTUDIOARCH.COM PROJECT TEAM OWNER'S REP VAIL RESORTS 137 BENCHMARK RD AVON, CO 81620 POC:CODY O'KELLY P:970.470.9139 CODYOKELLY@GMAIL.COM MECHANICAL / PLUMBING BA CONSULTANTS, INC. 240 ST. PAUL ST. SUITE #205 DENVER, CO 80206 POC:ALEX VALDEZ P:303.322.1212 ALEX.V@BA-CONSULTANTSINC.COM ELECTRICAL MV CONSULTING 2828 SPEER BLVD. SUITE 210 DENVER, CO 80211 POC:MARCUS BAHLING P:303.325.3271 MARCUS@MV-C.NET 08/15/17