HomeMy WebLinkAboutB17-0014_ED-PA-100A_1497477719.pdfSG HG SG SG K PANEL PPA PANEL PANEL PANEL K2A PANEL SL DN DN DN DN DN (TYP) 1 (TYP) 1 (TYP) 1 (TYP) 1 (TYP 1 (TYP) 2 (TYP) 2 (TYP) 2 (TYP) 2 4 4 3 3 3 3 SG HG SGSG K PANEL PPA PANEL PANEL PANEL K2A PANEL SL DN DN DN DN DN EF-3 FC-3 SG HG SG SG K PANEL PPA PANEL PANEL PANEL K2A PANEL SL DN DN DN DN DN 5 5 LOWER LEVEL ELECTRICAL DEMOLITION PLAN - AREA A ED-PA-100A 1. ITEMS SHOWN IN CROSS HATCHED AREA ARE N.I.C. AND EXISTING TO REMAIN UNLESS NOTED OTHERWISE. PROTECT ALL DEVICES TO REMAIN DURING DEMOLITION PHASE. 2. ALL ELECTRICAL FIXTURES, DEVICES AND EQUIPMENT AND LIGHTING FIXTURES AND DEVICES IN AREA SHOWN ARE TO BE REMOVED, UNLESS NOTED OTHERWISE. REMOVE ALL CONDUCTORS AND CONDUIT ASSOCIATED WITH DEVICE BACK TO SOURCE. 3. EXISTING PANEL TO BE RELOCATED. REFER TO E-100A FOR NEW LOCATION. REFER TO E-005 FOR DETAILS. 4. EXISTING PANEL TO BE DEMOLISHED. EXISTING CIRCUITS OUTSIDE OF SCOPE OF WORK ARE TO BE RECONNECTED TO NEAREST AVAILABLE LIKE PANEL DURING CONSTRUCTION PHASE. REMOVE ALL FEEDERS AND CONDUIT BACK TO SOURCE. 5. MECHANICAL UNIT TO BE DEMOLISHED. REMOVE ALL CONDUCTORS AND CONDUIT BACK TO SOURCE. ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE REVISIONS DESCRIPTION NO. FILE LOG STAMP 2017 © LEO A DALY Company Project No. 012-10378-000 AUGUST 19, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GO, KA Monroe & Newell alibre VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: VAIL HOTEL PARTNERS 1880 CENTURY PARK EAST SUITE 1016 LOS ANGELES, CA 90067 1. REFER TO DRAWING E-PA-001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. REFER DEMOLITION SECTION OF THE SPECIFICATION SHEET E-PA-004. COORDINATE WORK WITH OTHER DISCIPLINES. 3. IN AREAS WHERE NO WORK IS SHOWN, ALL EXISTING ELECTRICAL DEVICES AND EQUIPMENT ARE TO REMAIN, UNLESS NOTED OTHERWISE. ALL PROPOSED DEMOLITION WORK SHALL BE THOROUGHLY COORDINATED WITH THE LANDLORD PRIOR TO COMMENCING WORK. 4. WHERE EXPOSED, REMOVE ABANDONED CONDUIT. ALL CONDUIT ABANDONED IN THE SLAB OR CEILING SHALL HAVE ITS WIRING REMOVED AND SHALL BE LEFT PLUGGED-FLUSH WITH ITS COINCIDING SLAB OR CEILING. 5. REMOVE ALL ABANDONED HANGERS, SUPPORTS, ETC. FOR ELECTRICAL ITEMS. 6. WHERE ENCOUNTERED IN THE RENOVATION AREA, MAINTAIN OR RESTORE (WHERE INTERRUPTED) ANY WIRING DEVICES, RACEWAY OR CIRCUITS SERVING UNDISTURBED AREAS OF THE FACILITY. 7. WHERE ELECTRICAL DEVICES AND/OR CONDUIT ARE REMOVED, PATCH ALL HOLES IN SLABS, WALLS AND CEILINGS TO MATCH EXISTING CONSTRUCTION. ALL PATCHING SHALL BE MADE USING INTUMESCING FIRE SEALING MATERIAL. 8. REFER TO ARCHITECTURAL DOCUMENTS FOR ADDITIONAL INFORMATION AND DEMOLITION REQUIREMENTS. GENERAL CONTRACTOR TO NOTIFY ENGINEER IN WRITING OF AN DISCREPANCIES BETWEEN DOCUMENTS PRIOR TO WORK AND BID SUBMISSION. 9. ALL ITEMS ARE EXISTING, UNLESS NOTED OTHERWISE. 10. CONTRACTOR SHALL INCLUDE IN HIS BASE BID FOR CIRCUIT TRACING. 01/06/2017 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHOR OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHOR OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 09/09/2016 06/14/17