HomeMy WebLinkAboutB17-0014_ED-PA-100B_1497477720.pdfHGHG DN UP CT-1 CT-2 CB T T T T T T T CBCBCB 225A CB MKT STORAGE 75kVA 75kVA 75kVA 45kVA 150kVA 150kVA 400A CB MKT DB1 T6 400A TO HR3 TO LL1 ELD SITE LTG CONTROL HP2 EM1 200A ATS DISC. EM2 DISC. EM DISC. EM3 EM4 2000A MCB 2000A MCB 2000A1200A1200A MS-1 M M M M M T VFD VFD VFD GENERATOR 265kVA/211kW 480V, 3Ø VFD (TYP) 1 (TYP) 1 (TYP) 1 (TYP) 1 (TYP) 2 (TYP) 2 (TYP) 2 (TYP) 2 HGHG DN UP HG HG DN UP T T 3 3 4 4 4 4 LOWER LEVEL ELECTRICAL DEMOLITION PLAN - AREA B ED-PA-100B ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE REVISIONS DESCRIPTION NO. FILE LOG STAMP 2017 © LEO A DALY Company Project No. 012-10378-000 AUGUST 19, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GO, KA Monroe & Newell alibre VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: VAIL HOTEL PARTNERS 1880 CENTURY PARK EAST SUITE 1016 LOS ANGELES, CA 90067 1. ITEMS SHOWN IN CROSS HATCHED AREA ARE N.I.C. AND EXISTING TO REMAIN UNLESS NOTED OTHERWISE. PROTECT ALL DEVICES TO REMAIN DURING DEMOLITION PHASE. 2. ALL ELECTRICAL FIXTURES, DEVICES AND EQUIPMENT AND LIGHTING FIXTURES AND DEVICES IN AREA SHOWN ARE TO BE REMOVED, UNLESS NOTED OTHERWISE. REMOVE ALL CONDUCTORS AND CONDUIT ASSOCIATED WITH DEVICE BACK TO SOURCE. 3. MECHANICAL UNIT TO BE DEMOLISHED. REMOVE ALL CONDUCTORS AND CONDUIT BACK TO SOURCE. 4. ALL EXISTING ELECTRICAL DEVICES AND LIGHTING WITHIN ROOMS TO BE REMOVED BACK TO SOURCE. 1. REFER TO DRAWING E-PA-001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. REFER DEMOLITION SECTION OF THE SPECIFICATION SHEET E-PA-004. COORDINATE WORK WITH OTHER DISCIPLINES. 3. IN AREAS WHERE NO WORK IS SHOWN, ALL EXISTING ELECTRICAL DEVICES AND EQUIPMENT ARE TO REMAIN, UNLESS NOTED OTHERWISE. ALL PROPOSED DEMOLITION WORK SHALL BE THOROUGHLY COORDINATED WITH THE LANDLORD PRIOR TO COMMENCING WORK. 4. WHERE EXPOSED, REMOVE ABANDONED CONDUIT. ALL CONDUIT ABANDONED IN THE SLAB OR CEILING SHALL HAVE ITS WIRING REMOVED AND SHALL BE LEFT PLUGGED-FLUSH WITH ITS COINCIDING SLAB OR CEILING. 5. REMOVE ALL ABANDONED HANGERS, SUPPORTS, ETC. FOR ELECTRICAL ITEMS. 6. WHERE ENCOUNTERED IN THE RENOVATION AREA, MAINTAIN OR RESTORE (WHERE INTERRUPTED) ANY WIRING DEVICES, RACEWAY OR CIRCUITS SERVING UNDISTURBED AREAS OF THE FACILITY. 7. WHERE ELECTRICAL DEVICES AND/OR CONDUIT ARE REMOVED, PATCH ALL HOLES IN SLABS, WALLS AND CEILINGS TO MATCH EXISTING CONSTRUCTION. ALL PATCHING SHALL BE MADE USING INTUMESCING FIRE SEALING MATERIAL. 8. REFER TO ARCHITECTURAL DOCUMENTS FOR ADDITIONAL INFORMATION AND DEMOLITION REQUIREMENTS. GENERAL CONTRACTOR TO NOTIFY ENGINEER IN WRITING OF AN DISCREPANCIES BETWEEN DOCUMENTS PRIOR TO WORK AND BID SUBMISSION. 9. ALL ITEMS ARE EXISTING, UNLESS NOTED OTHERWISE. 10. CONTRACTOR SHALL INCLUDE IN HIS BASE BID FOR CIRCUIT TRACING. 01/06/2017 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHOR OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHOR OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 09/09/2016 06/14/17