Loading...
HomeMy WebLinkAboutB17-0014_FS-2-FS-2SC_1497476100.pdfSEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE G SEE NOTE D SEE NOTE D SEE NOTE G SEE NOTE A SEE NOTE G SEE NOTE D SEE NOTE A SEE NOTE A MARKET VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: VAIL HOTEL PARTNERS 1880 CENTURY PARK EAST SUITE 1016 LOS ANGELES, CA 90067 © 012-10378-000 DEC. 7, 2016 Engineers, Inc. Monroe & Newell 1/4" = 1'-0" 0000000000000000 1' 5' 10' SPECIAL CONDITIONS NOTES NOTE B: NOTE A: NOTE C: NOTE D: NOTE F: NOTE E: NOTE H: NOTE G: WORK DESCRIBED IN THESE NOTES IS TO BE ADDRESSED BY THE ARCHITECT NOTE I: NOTE K: NOTE J: · FINISHED CEILING IN KITCHEN SHOULD BE A MINIMUM OF 9'-0" (2700MM) AFF. · HAND FIRE EXTINGUISHERS AND FIRE BLANKETS LOCATED AND PROVIDED BY OTHERS ACCORDING TO LOCAL CODES . · MINIMUM WINDOW SILL HEIGHT TO BE AT 48" (1200MM) AFF UNLESS OTHERWISE SPECIFIED. · MINIMUM OF 36" (900MM) WIDE CIRCULATION/ AISLE SPACE REQUIRED. NOTE L: CONTRACTOR SHALL ENSURE ALL WALLS AND/OR CEILINGS ARE PROPERLY REINFORCED TO SUPPORT ALL WALL AND/OR CEILING SUPPORTED EQUIPMENT SEE DETAIL C1. N/A N/A N/A CONTRACTOR SHALL PROVIDE 6" (150MM) OR 8" (200MM) DIA. BEVERAGE CONDUIT (KELLY BEVWAY SYSTEMS CO.) BEVERAGE LINES (SODA OR BEER). ALL BENDS TO BE EASY SWEEPS (24" (600 MM) RADIUS MIN.) FOR 6" CONDUIT OR 30" (750MM) FOR 8" CONDUIT. CONTRACTOR TO RUN CONDUIT FROM BEVERAGE SYSTEM STORAGE TO DISPENSING POINT(S). RUN CONDUIT ON UNDERSIDE OF SLAB OR ABOVE FINISHED CEILING AS INDICATED AND PROVIDE SUPPORT AS REQUIRED. SEE DETAIL C4. CONTRACTOR SHALL PROVIDE DATA RECEPTACLES FOR POS, PRINTERS. N/A N/A N/A N/A N/A WALL BACKING (1150mm) (300mm) 3'-9" 1'-0" PRE-RINSE BRACKET 3'-6" 3'-0" (1050mm) (900mm) SINGLE / DOUBLE WALL SHELF, MOP RACK & ABOVE COUNTER WATER FILTER (450mm) (600mm) 1'-6" 2'-0" HAND SINK & UNDERCOUNTER WATER FILTER FINISHED FLOOR FINISHED CEILING ELECTRICAL DROP CORD, HOSE REEL & HANGING SHELVING CEILING BACKING EXHAUST HOOD (1800mm) (1050mm) 6'-0" 3'-6" WALL BACKING TO BE 3/4"-(20mm) F.R.T. PLYWOOD OR 16 GA.-(1.6mm) GALVANIZED METAL BY G.C. EXTEND WALL BACKING TO BOTH STUDS STUD BY G.C. FINISHED FLOOR FINISHED CEILING FINISHED FLOOR FINISHED CEILING FINISHED FLOOR FINISHED CEILING FINISHED FLOOR 2'-6" (750mm) FIRE SUPPRESSION SYSTEM CABINET FINISHED FLOOR FINISHED CEILING 1/2" (12MM) THREADED ROD W/ LEVELING TURNBUCKLES BY GC. ROD SECURED TO STRUCTURAL CEILING AND TO PLATE. 2' (600mm) X 2'(600mm) 14GA S/S PLATE BY GC, EXPOSED TIGHT AGAINST FINISHED CEILING IN KITCHEN, HIDDEN BEHIND DRY WALL SHEET IN PUBLIC AREAS. EQUIPMENT CENTERED AND SECURED TO PLATE BY KEC. FINISHED CEILING 9'(2700mm) TO 10'(3000mm) MAX. Scale: NONE WALL & CEILING BACKING December 09 C1 Detail EVERY 75' (22.5m) OR EVERY 3 BENDS 36" (900mm) FOR SODA/BEER/WINE LINES 24" (600mm) FOR SODA LINE PULL BOX DO NOT USE TIGHT 45 OR 90 BENDS MINIMIZE NUMBER OF BENDS NOTE: REMOVABLE ACCESS COVER 18" (450mm) (450mm) 18" (600mm) OR (900mm) 24"OR 36" FLOOR PULLBOX BY G.C. OR MECHANICAL TRADES CONDUIT BY ELECTRICAL REQUIRED BY CODE FOR OTHER MATERIAL I.D. PVC, OR 6" (150mm) OR 8" (200mm) VENDOR BY KEC OR SYSTEM WINE SODA/BEER/ TO 4" (100mm) THICK BE FILLED AND SEALED 2" (50mm) OPEN ENDS OF CONDUITS TO AFTER LINES INSTALLED, ALL VENDOR LINES BY KEC OR PULLBOX BY G.C. TYPICAL ALL BENDS 24" (600mm) RADIUS LONG SWEEP FINISHED CEILING STRUCTURAL FLOOR 4" (100mm) TO 6" (150mm) ABOVE FLOOR TYPICAL (450mm) 18" VENDOR LINES BY KEC OR STATION TO STATION DO NOT USE TEE FROM STATION 1 STATION 2 NOTE: Scale: NONE C4 Detail BEVERAGE LINE CONDUIT January 11 POOL BAR OUTDOOR GRILL AREA TO BE LOCATED CONTRACTOR SHALL PITCH FLOOR TO AREA DRAINS AT A MINIMUM OF 1/8" (3MM) PER FOOT. THIS CONDITION IS APPLICABLE IN WET SPACES SUCH AS CART WASH AREA, TRASH ROOM, DISHROOM AND POT WASH AREAS. Calibre 1 06/14/17