Loading...
HomeMy WebLinkAboutB17-0026_A1.1_1490036760.pdfDN 15.0' BUILDING SETBACK 8040 8040 8050 8050 8050 8050 S FRONT SETBACK ASPHALT DRIVEWAY ENTRY ENTRY WEST HOUSE EAST HOUSE GARAGE GARAGE SITE COVERAGE (HOUSES COMBINED) EXISTING = 3,859 SQ. FT. ADDITION = 0 SQ. FT. PROPOSED = 3,859 SQ FT. NEW SHED ROOF DORMER WITH 4/12 PITCH SHIGLE TO MATCH EXISTING 0 5' 10' 20 40 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/28/2016 9:51:26 AM 1454W Greenhill Court Vail, CO 81658 A1.1 SITE PLAN 1620 LANDERS RENOVATION PERMIT SET 07-28-16 John & Debra Landers 1" = 10'-0" 1 SITE PLAN SATELLITE PHOTO VICINITY MAP LOCATION Duplex Residence Owner: John and Debra Landers 2530 Outlook Trail Broomfield, CO 80020 Location: 1454 Greenhill Court #W, Vail, CO 81657 Glen Lyon Subdivision Lot 1 Parcel # 2103-124-02-011 PROJECT / CODE SUMMARY Class of Work: Alteration / Renovation / Addition Type of Construction: Type V-N Type of Occupancy: R3 (duplex) Levels: 2-story Sprinkler system : No 2 EAST ABOVE 3 NORTH ABOVE 5 STREET VIEW LANDERS PHASE II RENOVATION 1454 GREENHILL COURT #W, VAIL, CO Architect: Jeff Manley - Martin Manley Architects PO Box 1587 Eagle CO 81631 jeff@martinmanleyarchitects.com 970-328-1299 Sheet List Sheet Number Sheet Name A1.1 SITE PLAN A1.2 AREA PLANS A2.1 MAIN LEVEL AND ROOF PLAN A2.2 ELEVATIONS Project to have MORE than 50% of the existing gypsum wall board to remain intact INSULATION SUMMARY ALL MINIMUM INSULATION VALUES FROM IRC 2015 ROOF RAFTERS = R-51 (MIN. R-49) EXTERIOR WALL INSULATION = R-22 (MIN. R-20) WINDOWS U-VALUE MAX. = U-.30 (MAX. U-.31) INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR- BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES. LIGHTING SUMMARY EXTERIOR LIGHTING: (NONE IN THIS PROJECT) EXISTING EXTERIOR FIXTURES ARE DARK NIGHT SKY COMPLIANT AND WILL BE RE-USED IN NEW LOCATIONS. INTERIOR LIGHTING: GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT SECTION N1104.1 LIGHTING EQUIPMENT: "A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. ARCHITECTURAL INDEX SEE SHEET A3.1 - DETAILS & ENERGY CODE No. Description Date DESCRIPTION OF NEW PROPOSED: ADD NEW SHED DORMERS AT THE MASTER BEDROOM CEILING. NEW SHED DORMER NEW WINDOWS EXISTING ROOF FORMS NEW DORMER 03/20/17