HomeMy WebLinkAboutB17-0026_A1.1_1490036760.pdfDN
15.0'
BUILDING
SETBACK
8040
8040
8050
8050
8050
8050
S
FRONT SETBACK
ASPHALT
DRIVEWAY
ENTRY
ENTRY
WEST
HOUSE
EAST
HOUSE
GARAGE
GARAGE
SITE COVERAGE
(HOUSES COMBINED)
EXISTING = 3,859 SQ. FT.
ADDITION = 0 SQ. FT.
PROPOSED = 3,859 SQ FT.
NEW SHED ROOF
DORMER WITH 4/12 PITCH
SHIGLE TO MATCH EXISTING
0 5' 10' 20 40
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project number
Date REVISIONS
7/28/2016
9:51:26 AM
1454W
Greenhill
Court
Vail, CO 81658
A1.1 SITE
PLAN
1620
LANDERS
RENOVATION
PERMIT
SET
07-28-16
John & Debra
Landers
1" = 10'-0"
1
SITE PLAN
SATELLITE PHOTO VICINITY MAP
LOCATION
Duplex Residence
Owner: John and Debra Landers
2530 Outlook Trail
Broomfield, CO 80020
Location: 1454 Greenhill Court #W, Vail, CO 81657
Glen Lyon Subdivision Lot 1
Parcel # 2103-124-02-011
PROJECT / CODE SUMMARY
Class of Work: Alteration / Renovation / Addition
Type of Construction: Type V-N
Type of Occupancy: R3 (duplex)
Levels: 2-story
Sprinkler system : No
2
EAST ABOVE
3
NORTH ABOVE
5
STREET VIEW
LANDERS PHASE II
RENOVATION
1454 GREENHILL COURT #W, VAIL, CO
Architect: Jeff Manley - Martin Manley Architects
PO Box 1587
Eagle CO 81631
jeff@martinmanleyarchitects.com
970-328-1299
Sheet List
Sheet Number Sheet Name
A1.1 SITE PLAN
A1.2 AREA PLANS
A2.1 MAIN LEVEL AND ROOF PLAN
A2.2 ELEVATIONS
Project to have MORE than 50% of the existing
gypsum wall board to remain intact
INSULATION SUMMARY
ALL MINIMUM INSULATION VALUES FROM IRC 2015
ROOF RAFTERS = R-51 (MIN. R-49)
EXTERIOR WALL INSULATION = R-22 (MIN. R-20)
WINDOWS U-VALUE MAX. = U-.30 (MAX. U-.31)
INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY
PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT
INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL
INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR-
BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES.
LIGHTING SUMMARY
EXTERIOR LIGHTING: (NONE IN THIS PROJECT)
EXISTING EXTERIOR FIXTURES ARE DARK NIGHT SKY COMPLIANT
AND WILL BE RE-USED IN NEW LOCATIONS.
INTERIOR LIGHTING:
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT SECTION
N1104.1 LIGHTING EQUIPMENT:
"A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY
INSTALLED LIGHING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
ARCHITECTURAL INDEX
SEE SHEET A3.1 - DETAILS & ENERGY CODE
No. Description Date
DESCRIPTION OF NEW PROPOSED:
ADD NEW SHED DORMERS AT THE MASTER
BEDROOM CEILING.
NEW SHED DORMER
NEW WINDOWS
EXISTING ROOF FORMS
NEW DORMER
03/20/17