Loading...
HomeMy WebLinkAboutB17-0026_A1.2_1490036760.pdfUP UP UP 1335 SF E LOWER EXIST 600 SF W GARAGE 958 SF W LOWER EXIST 542 SF E GARAGE THIS AREA UNDER 5'-0" HEIGHT - NOT MEASURED FOR GRFA 2127 SF E MAIN EXIST 1657 SF W MAIN EXIST AREA OF 16'+ CEILING HEIGHT = 78 S.F. AREA OF 16'+ CEILING HEIGHT = 34 S.F. 10' - 2" 188 s.f. - Total Wall 84 s.f. - Unexposed Wall 617 s.f. - Total Wall 154 s.f. - Unexposed Wall 411 s.f. - Total Wall 0 s.f. - Unexposed Wall EAST UNIT - SOUTH EAST UNIT - EAST EAST UNIT - NORTH WEST UNIT - West 255 s.f. - Total Wall 0 s.f. - Unexposed Wall WEST UNIT - SOUTH 320 s.f. - Total Wall 123 s.f. - Unexposed Wall EAST UNIT - WEST 130 s.f. - Unexposed Wall 348 s.f. - Total Wall 305 s.f. - Total Wall 0 s.f. - Unexposed Wall WEST UNIT - NORTH 286 s.f. - Total Wall 160 s.f. - Unexposed Wall WEST UNIT - EAST LOWER LEVEL WALL SUMMARY (WEST UNIT) TOTAL WALL = 1,166 S.F. TOTAL UNEXPOSED WALL = 283 S.F. LOWER LEVEL AREA REDUCTION = 24% LOWER LEVEL WALL SUMMARY (EAST UNIT) TOTAL WALL = 1,564 S.F. TOTAL UNEXPOSED WALL = 368 S.F. LOWER LEVEL AREA REDUCTION = 23% EAST HOUSE - GRFA CALCULATIONS: TOWN OF VAIL ZONING REGULATIONS BASEMENT PERCENTAGE CALCULATIONS: TOTAL WALL SURFACE = 1,564 S.F. TOTAL UNEXPOSED WALL SURFACE = 368 S.F. PERCENTAGE OF UNEXPOSED WALL SURFACE = 23% LOWER LIVING EXISTING = 1335 S.F. GARAGE AREA = 542 S.F. TOTAL LOWER LEVEL = 1,877 S.F. UNEXPOSED DEDUCTION (23%)= -431 S.F. LOWER LEVEL SUB-TOTAL = 1,446 S.F. GARAGE EXEMPTION = -542 S.F. LOWER LEVEL GRFA TOTAL = 904 S.F. MAIN LEVEL EXISTING = 2,127 S.F. 16' VAULTED ADDITIONAL = 34 S.F. MAIN LEVEL GRFA TOTAL = 2,161 S.F. TOTAL GRFA = 3,065 S.F. The deduction shall be applied to all horizontal areas on the lowest level of a structure, including garages. EXISTING- (UNCHANGED) WEST HOUSE - GRFA CALCULATIONS: TOWN OF VAIL ZONING REGULATIONS BASEMENT PERCENTAGE CALCULATIONS: TOTAL WALL SURFACE = 1,166 S.F. TOTAL UNEXPOSED WALL SURFACE = 283 S.F. PERCENTAGE OF UNEXPOSED WALL SURFACE = 24% LOWER LIVING EXISTING = 958 S.F. GARAGE AREA EXISTING = 600 S.F. TOTAL LOWER LEVEL = 1,558 S.F. UNEXPOSED DEDUCTION (24%) = -374 S.F. LOWER LEVEL SUB-TOTAL = 1,184 S.F. GARAGE EXEMPTION = -600 S.F. LOWER LEVEL GRFA TOTAL = 584 S.F. MAIN LEVEL EXISTING = 1,657 S.F. 16' VAULTED = 78 S.F. MAIN LEVEL GRFA TOTAL = 1,735 S.F. TOTAL GRFA = 2,319 S.F. EXISTING (UNCHANGED) 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/28/2016 9:51:27 AM 1454W Greenhill Court Vail, CO 81658 A1.2 AREA PLANS 1620 LANDERS RENOVATION PERMIT SET 07-28-16 John & Debra Landers 1/8" = 1'-0" 1 01 Lower Floor 1/8" = 1'-0" 2 02 Main Floor 1/8" = 1'-0" 3 GRFA ELEVATIONS LOT AREA = .4274 ACRES x 43,560 SQ. FT. = 18,619 SQ. FT. SITE COVERAGE SUMMARY(BOTH HOUSES COMBINED): SITE COVERAGE - ALLOWED (25% OF SITE) = 4,654.8 SQ. FT. SITE COVERAGE - EXISTING = 3,859 SQ. FT. SITE COVERAGE - ADDITIONAL AVAILABLE = 795.8 SQ. FT. SITE COVERAGE - TOTAL unchanged = 3,859 SQ. FT TOWN OF VAIL ZONING DISTRICT: Two-Family Primary/Secondary Residential ZONING SUMMARY GRFA ALLOWED: 46% LOT AREA < 10,000 S.F. = 4,600 S.F. 38% LOT AREA < 15,000 S.F. = 1,900 S.F. 13% LOT AREA (3,619 S.F.) = 470 S.F. TOTAL GRFA ALLOWED = 6,970 S.F. GRFA - TOTAL EXISTING = 4,800 S.F. GRFA - TOTAL PROPOSED = 5,182 S.F. GRFA PRIMARY/SECONDARY SPLIT: WEST UNIT SECONDARY GRFA ALLOWED 40% = 2,788 S.F. SECONDARY GRFA EXISTING = 1,735 S.F. SECONDARY GRFA ADDITION = +584 S.F. SECONDARY GRFA TOTAL PROPOSED = 2,319 S.F. SECONDARY GRFA AVAILABLE AFTER = 469 S.F. EAST UNIT PRIMARY GRFA ALLOWED 60% = 4,182 S.F. PRIMARY GRFA EXISTING = 3,065 S.F. PRIMARY GRFA ADDITION = 0 S.F. PRIMARY GRFA AVAILABLE = 1,117 S.F. No. Description Date 2 Revision 2-ATTIC 07.23.14 03/20/17