Loading...
HomeMy WebLinkAboutB17-0066_A0-01_1506378874.pdf 4 ..„,,7640*.:;# rn 6 111/8" 41/8" 4r 63/4 43/4" PARTITION NOTES. 7/16" 7/16" iQD716 D 5/8 5/8" 5/8„ 5/8" 5/8" 1. STUD SPACING IS 16 INCHES ON CENTER MAX. O.N.U. 09/25/17 3 1/2" 2" 3 1/2" 5/8" C 3 1/2" 5/8" B 5 1/2" A 3 1/2" 2. REFER TO THE ARCHITECTURAL FLOOR PLANS FOR PARTITION `11.1111` TYPE INDICATORS. !." �--®�� 1 3. REFER TO (G SERIES SHEETS) FOR FIRE RATING LOCATIONS. j ' \ / -..y„ WHEPARTNTTONS MUST HEY ARE NDIOCATOEDMTO BE RATED ON TTO TESTED, DESSEMBLIES BOT. OFTR JOIST P w BOT. OF JOIST, r �I BOT. OF DECK, ARCHITECTURAL CODE PLANS. WHEN NO RATING IS INDICATED, RE: STRUCT FOR 0- ` GYP. BD. CEILINGS RE: STRUCT FOR GYP. BD. CEILINGS BOT. OF JOIST, GYP. BD. CEILINGS RE: STRUCT FOR _ GYP. BD. CEILINGS CONSTRUCT THE PARTITION PER THE INDICATED TYPE AS A NON TOWN STAMP SPECIFIC TYPICALLY OCCUR RE: STRUCT FOR _ CONDITIONS , TYPICALLY OCCUR AT SPECIFIC CONDITIONS TYPICALLY OCCUR SPECIFIC TYPICALLY OCCUR AT BOTTOM OF SPECIFIC AT BOTTOM OF RATED ASSEMBLY. ` BOTTOM OF JOISTS I AT BOTTOM OF 4. LABEL FIRE AND SMOKE WALLS AS FOLLOWS: LABEL BOTH CONDITIONS CONDITIONS 2X10 TOP PLATE RE: RCP'S TYP. JOISTS RE: RCP'S JOISTS RE: RCP'S �� JOISTS RE: FIN. TYP. I SIDES; LABEL ALL SECTIONS; USE 4" HIGH STENCILS; USE � � i TYP. SCHED. TYP. FLUORESCENT ORANGE PAINT; LOCATE ABOUT 12"ABOVE THE 1 LAYER 5/8"TYPE X FINISHED CEILING; SPACE STENCILS 10 FEET OC MAX; SPECIFIC =- ' GYP BD OVER 7/16" OSB SHEATHING LABELS TO READ "1 HR", "2HR", "1 HR SMOKE", "2HR SMOKE", EACH SIDE OF SCHED. "SMOKE", ETC AS IDENTIFIED IN THE LIFE SAFETY PLANS. 1.0-4� WD. STUDS. TYP. 5. PROVIDE STENCIL WITH THE LABEL"SOUND"AS DESCRIBED IN3 5 9 NOTE 3 ON ALL SOUND RATED WALLS IDENTIFIED BY A"S" SUFFIX ♦A ' - FULL-HEIGHT J FULL-HEIGHT FULL-HEIGHT AND THAT GO TO STRUCTURE. ? THERMAL INSUL THERMAL INSUL SOUND BATTS AT UNIT SIDE 1 GARAGE SIDE 1 "S" SUFFIX 6. PROVIDE FIRE STOP &SMOKE STOP SYSTEMS PER ?�A AT"T" SUFFIX, ,,,,:i AT"T"SUFFIX, SPECIFICATION AT ALL PENETRATIONS &OPENINGS (INCLUDING MIN. R 13 MIN. R 19 THE PERIMETER)THROUGH FIRE RATED WALLS. n I' FULL HEIGHT SOUND ` I 7. SEAL ALL PENETRATIONS &OPENINGS (INCLUDING THE ;� f lir �� BATTS AT"S"SUFFIX 5/8"TYPE X GYP BD 5/8" GYP BD DESIGN THERMAL INSUL AT I EA SIDE OF SCHED. EA SIDE OF SCHED. PERIMETER) PER SPECIFICATIONS IN ALL SOUND RATED WALLS = � =I F I�r INDICATED BY A "S" SUFFIX. "T" SUFFIX, MIN. R-26 5/8" GYP BD ONE WD. STUDS. TYP. WD. STUDS. TYP. SIDE OF SCHED 8. THE PARTITION TYPES INDICATE THE BASIC WALL _ SEALANT ` SEALANT CONSTRUCTION ONLY. REFER TO ALL OF THE CONSTRUCTION © WD. STUDS. TYP. @ DOCUMENTS FOR OTHER REQUIREMENTS INCLUDING: SOUND, SMOKE, SEALANT© SOUND, SMOKE, Iry FIRE ��% SOUND, SMOKE, �/ FIRE MECHANICAL, ELECTRICAL, PLUMBING, BLOCKING &BACKING, C01� FIRE WALL BASE, WALL FINISH, AND RECESSED &SURFACE MOUNTED ,� EQUIPMENT. i ii*I'\1‘:• ��'�' ��.GARAGE DEMISING WALL W/5/8" GYP. BD. NON-RATED 1 HR RATED- 1 HR ONE WALL NON-RATED 9. PROVIDE TESTED, RATED ASSEMBLIES AT THE TOP OF ALL / 44 \PARTITIONS INDICATED TO BE FIRE OR SMOKE RATED THAT D FURRING PARTITION UL FILE# UXXX STC XX EXTEND TO THE BOTTOM OF STRUCTURE OR DECK ABOVE. ALL B-2465 WIDTH DESCRIPTION SUFFIX WIDTH DESCRIPTION SUFFIX WIDTH DESCRIPTION SUFFIX WIDTH DESCRIPTION SUFFIX ORSSEMBLIES SHALL BTESTED BY UTLABORATORY OTHER TESTING FAA CILITY ACCEPTAABBRWRITERS LE TO THE AUTHORITY e i•11 3/8" TYPE D1 3 1/2" DBL. WD. STUD S SOUND 4 1/8" TYPE Cl 3 /2"WD. I, ON " IE S Si.! • 6 /4" ' 'E B1 5 1/2" B. TUD SOUND 4 3/4" TYPE ' 3 1 D. STUD SOUN3 HAVING JURISDICTION. PROVIDE A FIRE AND SMOKE RATING ��� ,`c� r.T THERMAL T THERMAL T THERMAL 6 3/4" TYPE A2 5 1/2"WD. STUD T THERMAL CONSISTENT WITH THE PARTITION. �sto ARtO 1,-3 1/8" 1' -3 1/8" DISCIPLINE STAMP F 5/.8„ 7/16" 7/16" 7/16" 7/16" 5 1/2" 2" 5 1/2" 5/8" E 5/8". 5 1/2" 2" 5 1/2" , 5/8" BOT. OF JOIST, =► BOT. OF JOIST n►� � " mrlwF _ ®I RE: STRUCT FOR GYP. BD. CEILINGS RE: STRUCT FOR GYP. BD. CEILINGS SPECIFIC TYPICALLY OCCUR AT SPECIFIC TYPICALLY OCCUR AT CONDITIONS _ BOTTOM OF JOISTS CONDITIONS BOTTOM OF JOISTS RE: RCP'S TYP. RE: RCP'S TYP. -41411111.41, ______ 2"AIR SPACE TYP. 2"AIR SPACE TYP. 21 1 - — 1 LAYER 5/8"TYPE X 1 LAYER 5/8"TYPE X Q l , GYP BD OVER 1 LAYERraloi, � ♦ = GYP BD OVER 1 -4b _44.441! ____ 1111 Alt f 7/16" LP FLAMEBLOCK I LAYER 7/16"OSB 1HR RATED OSB EACH _ SHEATHING EACH AlSIDE OF SCHED.WD. SIDE OF SCHED. WD. , STUDS. TYP. STUDS. TYP. _--- FULL HEIGHT _11 - -Al FULL-HEIGHT ._...,,.... BATT INSULATION, 14-W-41111111W-441 � - BATT INSULATION, FOR SOUND TYP. (TOFOR SOUND TYP. (TO MAINTAIN UL LISTING) MAINTAIN UL LISTING) Z 1 111111.r 11111A11111111 SEALANT @ SOUND, 0 -"IMF 1111111P--111111111 SEALANT @SOUND, -� SMOKE, FIRE SMOKE, FIRE x •H( {R; m 2 HR RATED -2 HR COMMON WALL RATED 2 HR FROM BOTH SIDES 1 HR RATED - 1 HR COMMON WALL RATED 1 HR FROM BOTH SIDES ICE UL FILE#U350-STC 53 UL FILE#WP 3370-STC 53 WIDTH DESCRIPTION SUFFIX WIDTH DESCRIPTION SUFFIX 1'-3 3/4" TYPE Fl 5 1/2" DBL. WD. STUD S SOUND 1' -3 1/8" TYPE El 5 1/2" DBL. WD. STUD S SOUND T THERMAL T THERMAL 5/8 7/16" 1 1/4" /8" 5/8" 7/16" 1" 5 1/2" (1'y 5 1/2" 5 1/2" 101 '� _ lirre ISSUE STANDING SEAM METAL 1: HORZ. STAINED CEDAR HORZ. STAINED CEDARHORZ. STAINED CEDAR SHIP TOWN OF VAIL PERMIT ROOF, RE: SPEC. Er 1■ SHIP LAP SIDING, RE: SPEC SHIP LAP SIDING, RE. SPEC LAP SIDING, RE: SPEC HIGH TEMPERATURE ICE Ij1 r RAINSCREEN SYSTEM, RE: SET RAINSCREEN SYSTEM, RE: RAINSCREEN SYSTEM, RE: AND WATER SHIELD OVER v� SPEC. III SPEC. SPEC. ENTIRE ROOF SHEATHING, v�RE: SPEC. PREMIUM ASHPHALT V, 1" MIN. R-5 FOIL FACED KEY PLAN i 1" MIN. R-5 FOIL FACED 1" MIN. R-5 FOIL FACED SHINGLES, RE: SPEC. POLYISO INSULATION FULLY 19/32" ROOF SHEATHING, u. POLYISO INSULATION FULLY POLYISO INSULATION FULLY TAPED AT ALL SEAMS, RE: TAPED AT ALL SEAMS, RE: - TAPED AT ALL SEAMS, RE: —RE: STRUCT. ICE AND WATER SHIELD = ♦ 1li SPEC. ' SPEC. SPEC. i OVER ENTIRE ROOF 7/16" EXTERIOR OSB 2X RAFTER FRAMING, SHEATHING, RE: SPEC. I 2 LAYERS 5/8"TYPE-X EXT. 1 LAYER 5/8"TYPE-X EXT. SHEATHING, RE: SYSTEMS RE: STRUCT. ♦ I� P GYP. BD. GYP. BD. 19/32" ROOF SHEATHING, , II■U — BUILT MFR. CEMENT BOARD RE: STRUCT. Y �� R-21 MIN. UNFACED BATT R-21 MIN. UNFACED BATT R-21 MIN. UNFACED BATT SOFFIT, RE: SPEC. IIi H INSULATION, RE: SPEC. - INSULATION, RE: SPEC. ROOF TRUSS RE: STRUCT. 1■ INSULATION, RE SPEC. "IN I- 2X6 WOOD FRAMED WALL 2X6 WOOD FRAMED WALL —I 2X6 WOOD FRAMED WALL Will11111 5/8"TYPE-X GYP. BD. OVER 7/16" LP FLAMEBLOCK 2HR RATED OSB 5/8"TYPE-X GYP. BD. OVER 7/16" OSB SHEATHING I SHEATHING 5/8"GYP. BD. SHEET TITLE 1 HR RATED 1 HR RATED FILE#EEV 10288 LP AMENDED W408 UL FILE#WP 3605 STANDARD RS2 - STANDING SEAM ROOF RS1 - ASPHALT ROOF WS4.1 - WOOD SIDING - 2 HR WS4 - WOOD SIDING - 1 HR WS3 - WOOD SIDING PARTITIONS & 1 1/2" = 1'-0" 1 1/2"= 1'-0" 1 1/2"= 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1-0" EXTERIOR VARIES VARIES ASSEMBLIES 5/8" 7/16" 1 1/4" 5/8"47/16" 5/8" d 5 1/2" „ 5 1/2" N 1 5/8" 5 1/2 6" ��1/2" PER MFR. 1 1/2" 4k RE: STRUCT. RE: STRUCT. j 4y _ i 1 1 REVISION �/ _ - No. Description Date d Si I I■1a �; 1 ASI 001 08-28-2017 2 COAT STUCCO SYSTEM T. 2 COAT STUCCO SYSTEM 2 COAT STUCCO SYSTEM OVER I■1 ° PROTECTION BOARD, RE: SPEC. ° a'-°, OVER GALVANIZED METAL I' 40 I■1 a - ' a OVER GALVANIZED METAL GALVANIZED FURRED WIRE II.1 I ° c LATH, RE: SPECW —I,' LATH, RE: SPEC I MESH, RE: SPEC 2 COAT STUCCO SYSTEM OVER ■1' DRAINAGE MATT, RE: SPEC. GALVANIZED FURRED WIRE MESH, I I■1IMI- mp RAINSCREEN SYSTEM, RE: _L RAINSCREEN SYSTEM, RE: RAINSCREEN SYSTEM, RE: RE: SPEC ��I - ° DAMPROOFING, RE: SPEC. _ x I SPEC. I:' SPEC. SPEC. I■1 a p' _ I ° ° c RAINSCREEN SYSTEM, RE: I■1( ° a a 1 1/2" POLYSTYRENE s 1" MIN. R-5 FOIL FACED POLYISO 1" MIN. R 5 FOIL FACED POLYISO 1 1/2" R 7.5 MIN. RIGID I■1 ^' ° = INSULATION FULLY TAPED AT I'; SPEC. I■1 INSULATION BOARD, RE: SPEC. — _ INSULATION FULLY TAPED AT INSULATION, RE: SPEC. I■1 , _ I ir ALL SEAMS, RE: SPEC. ALL SEAMS, RE: SPEC. 1 1/2" FOIL FACED POLYSTYRENE Al,a ° =I' d°° °° FLUID APPLIED MEMBRANE - -I a - ° 7/16" EXTERIOR OSB I■1 °' a - , ° . d 1 -4A ► `� Ailip INSULATION BOARD, RE: SPEC. I■1 ° AIR BARRIER, RE SPEC. i. a °.. ' ■I i 2 LAYERS 5/8"TYPE X EXT. .\ 1 LAYER 5/8"TYPE-X EXT. I SHEATHING, RE: SYSTEMS �1■1 ° _ . o ■I i GYP. BD. r I, GYP. BD. AI : BUILT MFR. CAST IN PLACE CONCRETE WALL, 1�� a° c il, MI a : CAST IN PLACE CONCRETE WALL, ;, ♦ I , THICKNESS VARIES, RE: STRUCT °�a. THICKNESS VARIES, RE: STRUCT I ° °^m � R-21 MIN. UNPAGED BATT !4 R-21 MIN. UNFACED BATT R-21 MIN. UNFACED BATT liii ° - °�� INSULATIONRE: SPEC. I INSULATIONRE: SPEC. : : ,_,, _,, INSULATIONRE: SPEC. FURRING PARTITION WHERE '� _ _ - ° FURRING PARTITION WHERE a !!. -I „ ° ' M( 2X6 WOOD FRAMED WALL — APPLICABLE, RE: PLANS j:l. �- a. APPLICABLE, RE: PLANS �, .� - a. ■I 2X6 WOOD FRAMED WALL 2X6 WOOD FRAMED WALL is _ - _ a ■I — ? ® 5/8"TYPE-X GYP. BD. OVER 7/16" LP I■1, - ° - ■I —I r 5/8"TYPE-X GYP. BD. OVER 7/16" 5/8"GYP. BD. ,�,, a,° - °; , _-°- . I �= a.a . : a. p i6 MI FLAMEBLOCK 2HR RATED OSB OSB SHEATHING I I�1; _ °` SHEATHING 1 HR RATED 1 HR RATED PROJECT NUMBER 14054.1 FILE# EEV 10288 LP AMENDED W408 UL FILE#WP UL 3605 ISSUE DATE MAY 31, 2017 2 WS2.1 - STUCCO - 2 HR WS2 - STUCCO - 1 HR WS1 - STUCCO FWS-2 - FOUND. WALL - STUCCO FWS-1 - FOUND. WALL - BELOW GRADE a SHEET NO. N 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" N O N A0 . 01 0 N