HomeMy WebLinkAboutB17-0066_A3-01-01_1498500448.pdf z. NOTE: I "7 GRAY HATCH INDICATES SYSTEMS b BUILT SCOPE, TYP. ° -1120111°k, 06/26/17 LIGHTING LEGEND FINISH PLAN GENERAL NOTES REFLECTED CEILING NOTES: FLOOR PLAN GENERAL NOTES 1'X 4' FLOURESCENT 1. REFER TO SHEET A3.01 FOR FINISH SCHEDULE 1. NOTIFY ARCHITECT OF DISCREPANCY UPON DISCOVERY 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 6" RECESSED LIGHT 2. ALL WALLS TO BE P-01, EGGSHELL. ALL TRIM TO BE P-02, PRIOR TO PROCEEDING WITH SAID WORK. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF LIGHT EGGSHELL. ALL CEILINGS TO BE P-02, FLAT. 2. ALL CEILING SHALL BE 9'-0"A.F.F, UNLESS NOTED STRUCTURE U.N.O. TOWN STAMP A 3. ALL WALL BASE TO HAVE MITERED EDGES. OTHERWISE. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 0 JUNCTION BOX 4. EQ-05& EQ-06 WASHER AND DRYER ARE SIDE-BY-SIDE OR 3. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE Al' U.N.O. = EXTERIOR WALL LAMP STABKABLE UNITS. REFER TO PLANS FOR INSTALL TYPE. OF SPRINKLER HEADS. CENTER FIRE SPRINKLER HEADS 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, BOTH DIRECTIONS IN CEILING TILES.ALL CORRIDOR U.N.O. SPRINKLER HEADS SHALL BE ALIGNED AND CENTERED 6. OR ND YE O IN SAID SPACE. BUILTFLOMAFR. STANDARDSCEILING TOFRAMING BE REVIEWEDSYSTEMS EERY SARCHITESTMSCT. FLUSH MOUNT CEILING LIGHT • 4. SUBMIT LAYOUT OF ALL GYPSUM BOARD CEILING 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR • o • CEILING FAN W/ CONTROL JOINTS FOR REVIEW. DRAWINGS 359 iie, .,‘ LIGHT 5. MINOR DISCREPANCIES BETWEEN MEP AND 8. RERCN ARCHITECTURAL DOCUMENTS IN REGARD TO LOCATION 9. REFER FUTONITURE THE IS A3 SERIESSHOWN FOR FORREFUNIT ENPLANSEO ,LY WHICH INCLUDE VANITY WALL LIGHT OFLUN , CHFLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT REFLECEICTEDING MOCEILING TEDF LANCOMPONENTSSHALL GOVERN.ARITECTURAL LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL 6. RE: MECHANICAL AND ELECTRICAL DRAWINGS FOR 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND DESIGN MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS FOR DESIGNATIONS OF EXTERIOR MATERIALS. ® BATHROOM CEILING FAN O 18" DRUMB PENDANT REQUIRED OR INDICATED. 7. 11. REFERSECTIONS TO THE A5 SERIES FOR ALL BUILDING AND WALL ALL MOR PARTITIONIN , WALL ECHANICAL/BASSEMBLYILER TOOOMS;STRUCTURECONTINUE OR 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW BOTTOM OF CEILING WITH FIRE STOPS AS REQUIRED IN INFORMATION, SCHEDULES AND DETAILS 0 4.8" PENDENT LIGHT I- INTERSTICIAL SPACE. SEAL ALL JOINTS PER SYSTEM. 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR GARAGE DOOR FINISH INFORMATION AND SCHEDULES L J OPERATOR PROVIDE FIRE SEALANT AT ALL PENETRATIONS AND r Co 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE #. L/ . HEADS OF WALL •`�. 8. CEILINGS ABOVE SHOWERS/BATHS WILL RELIEVE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY Q� "� '�� MOISTURE RESISTANT GYP. BD., TYPE 'X' LOCATED COMMON AREA PER LOCAL CODE (� �.V \j' 9. PENDANT LIGHTS ABOVE KITCHEN BAR TO BE SET 2' 6" NS 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD i ABOVE COUNTER HEIGHT. PRE-MARK AND VERIFY ALL INSTALLATIONS THAT OCCUR AT SLAB ON GRADE D. KEYNOTE LEGEND - GENERAL LOCATIONS W/ INTERIORS. CONDITIONS 0-2465 10. PROVIDE BATT INSULATION IN ALL FLOORS, CEILING AND 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, KEY NOTE WALLS SURROUNDING BATH/SHOWER, MECHANICAL CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR �/� �~ ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC C" AND WASHER/DRYER ROOMS/CLOSETS. /��` \� 11. CENTER ALL CEILING GRIDS IN EACH ROOM OR SPACE 17. USE 5/8"TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS fp Mit 003 STACKABLE WASHER AND DRYER RE:EQUIPMENT SCHEDULE UNLESS OTHERWISE INDICATED WITH A GRID ORIGIN OR 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. -- - DIMENSION. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL DISCIPLINE STAMP 12. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING ARE INDICATED WHERE ARCHITECTURALLY SIGNIFICANT. 20. GUARDRAILSTHEREISAGRADE ARE REQUIREDCHANGEOF AT 30ALL" OR LOCATIONSMORE WHERE 13. SPRINKLER SPRINKLER TO BE DESIGNED BY FIRE PROTECTION ENGINEER. COORDINATE ALL LOCATIONS WITH ARCHITECT. 14. ALL LIGHT FIXTURES IN MECH, CLOSETS AND LAUNDRY SHOULD BE CENTERED IN ROOM IN BOTH DIRECTIONS, UNO. al I X ❑❑ ❑❑ 2 - `.5.01-0 Z 0 H 10 0 , a(.' I. - ' , , , , , , „ . _, , ,r., ,, , ,- 0 :'- . I �> , • - ' _- -- -- -._ : y• _ - - r1tV � _ I I C1 2.1-04J II WATER ENTRYWATER ENTRY - 7'- -,-‘,;:"'"-'- - - • CLOSET -� T n - - ii - �� - CLOSET - i BEDROOM 2 4 BEDR2' M _ - <Lt. B1 ll I I N I - I �� I • CPT 01 , �< I I ISSUE t - - - ��,I" 5 4 7/8" 2' 7 3/4" I - - - - F' - -- - � � --MOLD-- Eo w _ a i • o TOWNVAIL , --- - I �� . , • Al OF AI PERMIT co in �DJ OO1lIF'2 :i<' �; SET A6.01 11 111111 E I D1• KEY PLAN PL 14 . _ , fir 'illH I 2.1-03 0z71- rt I (.,, I - PT-�1- pm. - • - �C . 0 1 - I CO P1 1 . 7, ,, 1 ,E, 1 ,,, 711...111.. :---, -- :. -,-,1:-,-.:1?'"- O 1 CAR GARAGE •A. co 1CAR GARAGE 1. , : , :1/A • 0 PL 03` "�,-� 1,=GAi 'EAY2AGE_ I a G G 1: .' �� 1 -. _ • BATH ..TI _ t, I i =ir PL-01 FI PL 10 I I C L II SHEET TITLE - - - - Al �UNDRY . 11: _ -i� ll 1 Tp•. - N Y E - LAU DR - -06 Q - - - I NT ���' BUILDING01 U I 2.1 I n _ 0 E -05 Q I Ch LEVEL I - • A EVE 01 i ill , . , 003 .•�', 0 C1 ENTRY ao H - - - Ii �y \----'cNi ii,,a11 ;, a, - IIIIilIiiI 1 1 - - - - ��SC "Y illillilli111111 I Is - - ;, ,Q� - W$ 2.107 ...._, d LL <_" _ c� REVISION y E�I*�L �_I ■� _i L '- �, s I No. Description Date 0 A B I .O 0 _l O r J - 1rn • OVERHANG ABOVE - m c ❑ 1/-41/p" 3'-2" 1'-6'j 3'-07/8" 2'-6" , 0 2 a , 1/2' N ❑ 0 II � ❑ ❑ E u 0 0 `m a iu'm U PROJECT NUMBER 14054.1 ISSUE DATE MAY 31,2017 a SHEET NO. 03 UNIT 2.1 A - LEVEL 01 - FINISH PLAN UNIT 2.1 - LEVEL 01 - RCP UNIT 2.1 A - LEVEL 01 - FLOOR PLAN Tr 41 N. , 3 1/4"= 1' 0" 2 1/4"= 1'-0" 11/4"= 1'-0" A3 . 01 01 N 45