HomeMy WebLinkAboutB17-0066_A3-05-01_1498500449.pdf 10 OF gele 1 NOTE: Is "7 GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP. °')-10o1j9's 06/26/17 LIGHTING LEGEND FINISH PLAN GENERAL NOTES REFLECTED CEILING NOTES: FLOOR PLAN GENERAL NOTES 1'X 4' FLOURESCENT 1. REFER TO SHEET A3.01 FOR FINISH SCHEDULE 1. NOTIFY ARCHITECT OF DISCREPANCY UPON DISCOVERY 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 6" RECESSED LIGHT 2. ALL WALLS TO BE P-01, EGGSHELL. ALL TRIM TO BE P-02, PRIOR TO PROCEEDING WITH SAID WORK. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF LIGHT EGGSHELL. ALL CEILINGS TO BEP 02, FLAT. 2. ALL CEILING SHALL BE 9' 0"A.F.F, UNLESS NOTED STRUCTURE U.N.O. TOWN STAMP A 3. ALL WALL BASE TO HAVE MITERED EDGES. OTHERWISE. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 0 JUNCTION BOX 4. EQ-05& EQ-06 WASHER AND DRYER ARE SIDE-BY-SIDE OR 3. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE Al' U.N.O. EXTERIOR WALL LAMP STABKABLE UNITS. REFER TO PLANS FOR INSTALL TYPE. OF SPRINKLER HEADS. CENTER FIRE SPRINKLER HEADS 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16"OSB SHEATHING, BOTH DIRECTIONS IN CEILING TILES. ALL CORRIDOR U.N.O. SPRINKLER HEADS SHALL BE ALIGNED AND CENTERED 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS O IN SAID SPACE. BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. FLUSH MOUNT CEILING LIGHT • 4. SUBMIT LAYOUT OF ALL GYPSUM BOARD CEILING 7. ALL CLOSETS TO INCLUDE SHELF& ROD RE: INTERIOR • o • CEILING FAN W/ CONTROL JOINTS FOR REVIEW. DRAWINGS LIGHT 5. MINOR DISCREPANCIES BETWEEN MEP AND 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 359 i ‘ ARCHITECTURAL DOCUMENTS IN REGARD TO LOCATION 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE VANITY WALL LIGHT OF CEILING MOUNTED COMPONENTS,ARCHITECTURAL FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT REFLECTED CEILING PLAN SHALL GOVERN. LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL 6. RE: MECHANICAL AND ELECTRICAL DRAWINGS FOR 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND DESIGN MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS FOR DESIGNATIONS OF EXTERIOR MATERIALS. ® BATHROOM CEILING FAN O 18" DRUMB PENDANT REQUIRED OR INDICATED. 7. IN ALL MECHANICAL/BOILER ROOMS; CONTINUE 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW PARTITION, WALL ASSEMBLY TO STRUCTURE OR BOTTOM OF CEILING WITH FIRE STOPS AS REQUIRED IN INFORMATION, SCHEDULES AND DETAILS 0 4.8" PENDENT LIGHT r INTERSTICIAL SPACE. SEAL ALL JOINTS PER SYSTEM. 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR GARAGE DOOR FINISH INFORMATION AND SCHEDULES L J OPERATOR PROVIDE FIRE SEALANT AT ALL PENETRATIONS AND r C� 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE L/ , HEADS OF WALL ��. 8. CEILINGS ABOVE SHOWERS/BATHS WILL RELIEVE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY ' S'1� 40 MOISTURE RESISTANT GYP. BD., TYPE 'X' LOCATED COMMON AREA PER LOCAL CODE /�1• P \j' 9. PENDANT LIGHTS ABOVE KITCHEN BAR TO BE SET 2'-6" 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD ABOVE COUNTER HEIGHT. PRE-MARK AND VERIFY ALL INSTALLATIONS THAT OCCUR AT SLAB ON GRADE • o KEYNOTE LEGEND - GENERAL LOCATIONS W/ INTERIORS. CONDITIONS B-2465 10. PROVIDE BATT INSULATION IN ALL FLOORS, CEILING AND 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, KEY NOTE WALLS SURROUNDING BATH/SHOWER, MECHANICAL CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR e•ee, Vti ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC tr '`� AND WASHER/DRYER ROOMS/CLOSETS. /��` *\ 11. CENTER ALL CEILING GRIDS IN EACH ROOM OR SPACE 002 22X30 17. USE 5/8"TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS fp Mit ACCESS PANEL; RE: SPECS. 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. UNLESS OTHERWISE INDICATED WITH A GRID ORIGIN OR �~ DIMENSION. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL DISCIPLINE STAMP 12. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING ARE INDICATED WHERE ARCHITECTURALLY 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE SIGNIFICANT. THERE IS A GRADE CHANGE OF 30" OR MORE 13. SPRINKLER SPRINKLER TO BE DESIGNED BY FIRE PROTECTION ENGINEER. COORDINATE ALL LOCATIONS WITH ARCHITECT. 14. ALL LIGHT FIXTURES IN MECH, CLOSETS AND LAUNDRY SHOULD BE CENTERED IN ROOM IN BOTH DIRECTIONS, UNO. a ® 1 A6.04 5.02-0 X 1'-35// 2'-6" , 6'-4" , 2'-6" J, / 3'-6" , 2'- 10" , 3'-21/8" / Z 0 1 . 1 ® ® ® ® 4 , __ __ _. ._, . . . , .., I • . , "i" • ili • . HALLINAY I ' - Q - 0.2-20: s ,-JHALLWAY a -' r< '> CM= EQ-05 CPT 01 ' -'''"I's'.-'-',-':,:,- ;4�tiwigV 4�- {E � / _ _ J 2' 0 E _ 'EQ> - ti - - - - - - - CnT�`�:«'=;.�' - 3'- 1' 5' 1 1/4" 3' 11 3/8" � � '` '.,�� HOLD BEDROOM 2 <> fl- i: , ,, 1r-+', �_;;_ c, a, BEDROOM 2 C 0 , rn ISSUE LVT 01 - . - - - - - - - - - '4•� -� _ €.2-208 - - - - - - - - - - - - _�,• �' -,_';,2-,,:,- - - Vis. � Lv r 01 CP 1 _ •r,�, =� _ - _ TOWN OF AI PERMIT LAUNDRY E1 - - E1 I - •- - -s'' --' - - - - �,.: _ • SET '�•'`' i1 _ KEY PLAN W' =1r aI ',, CA,R' ` ;M 2: N N N ri SPC 04 `�'• ` b 002 - N N \, N. ��' ,cv Ltl i" CLOSET 0 CLOSET '') 61 - • _ _ ' - ;:- I• : o m BATH _ - - -:_,-,:,:., :4)::•,j,-::,.:•::,;• • i" �•;. /\12 - �i.2 200 BATH o .- CT 01 PL-03 2 >•4 A6.04 , \ , CLOSET • Q;;__ CLOSET �,`= � �_ 5-7 3/8" I 5-7 1/4" PL 01 `t" � - = Liromr 5 171 - -'cam- J0.010 s''`_ -;> 1 , ‘M iii �(A�01. {� -'�' -:i SHEET TITLE _ _ o BUILDING 01 NIT .2 7_ mac- U 3 1E--:'';‘-:,:::,: ::', 01 N A .: . � ., , , A - LEVEL 03 MASTER MASTER BEDROOM '': -� '.- - a• -- _ S s ♦ - BEDROOM 'CPT-01 PL 4 0 - T RB,4W 1 lir ,----h ‘- i.6 A .04/ 4 0 /5 MASTER BATH mcd • - -_ ,IVIAS:TER'-`' 'a =„ a ;<' MASTER BATH o `m CPT Ob I UZ T 02 to REVISION PL-04 - - .2-2 0 - - N Description oDate ] „ :- ._ ' ' " „ " '" : - I ° J O •0 �I$� X U Z �/ O m a g- 0 N - d IL. L 5 3 u 0 0 `m m `m a 'm m 3 / / / // /3'- 1" 7' 6" 3' 1 ' 3' 2 3/4" 4'-0,. u 'r PROJECT NUMBER 14054.1 I ISSUE DATE MAY 31,2017 a SHEET NO. M N v r UNIT 3.2 A - LEVEL 03 - FINISH PLAN UNIT 3.2 A - LEVEL 03 - RCP UNIT 3.2 A - LEVEL 03 - FLOOR PLAN A3 , 05_01N 1/4"= 1'-0" 1/4"= 1'-0" 1/4"= 1'-0"