Loading...
HomeMy WebLinkAboutB17-0066_A9-05_1508792409.pdf NOTE: z: GRAY HATCH INDICATES SYSTEMS o. BUILT SCOPE,TYP. 31231201 '' HORZ.STAINED CEDAR SHIP 10/23/17 EXTERIOR 5/8"GYP. BD. LAP SIDING, RE:SPEC V WALL BEYOND. RE.PLAN 1'X4" BASE TRIM, RE: RAINSCREEN SYSTEM, RE:SPEC. CONC. SLAB @GARAGE DOOR -,1 FINISH SCHEDULE OPENING, RE:STRUCT. RE: FINISH SCHEDULE 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION, 2" INSULATION BOARD 4 RE: SPEC. TOWN STAMP 7/8"T&G PLYWOOD SHEATHING, UNDER SLAB VAPOR RE:SYSTEMS BUILT MFR. 40 7/16"EXTERIOR OSB SHEATHING, BARRIER, RE:SPEC. RE:SYSTEMS BUILT MFR. 2X6 SILL PLATE GRANULAR FILL,RE:STRUCT. SEALED CONC.GARAGE FLOOR, 3 5 9 _ _ (2) 2X12 RIM JOISTS RE: FINISH SCHEDULE Irr•;; SPRAY FOAM INSULATION, R-21 GARAGE T.O.CONC. ..•�� MIN. = ••-'�� I01111 PREFINISHED METAL FLASHINGFIBEROUS EXPANSION _ __ a d °MATERIAL, RE:CIVIL • - - °2 2X6 SILL PLATES -fir���� _-_��������_ o O O o ° d ____.._________ DESIGN ❖.❖� 4"ASPHALT DRIVEWAY OVER � • • • , _� .� �,,�,, " .....• ;;;;7 5/4"x4"STAINED CEDAR ) ��F� �� OVER GRANULAR FILL,RE:CIVIL. • • • • • • • • • :':�:�:� TRIM, RE:SPEC. •�• ����c ° -° P ° : �. •. i:�. •.r,•. �. �• ° d e xbirtriliga BACKER ROD AND SEALANT DRAINAGE SYSTEM I-PROTECTION , -j ,d STUCCO J BEAD CLOSER BOARDOVER DRAINAGE MATT - -a - _ 5/8"GYP. BD. a OVER RIGID INSULATION, RE:SPEC. �_ '' d° _a_ a CO/ 2 COAT STUCCO SYSTEM OVER ��. - � Ater/GALVANIZED FURRED WIRE MESH, °e i A+r/t' t RE: SPEC FLUID APPLIED MEMBRANE AIR o-° d .° /i'' ` - . _ �y, BARRIER, RE:SPEC. 1 ° ' --" - ••.• D. • TSS 1 1/2" R-7.5 MIN.POLYSTYRENE - B_25 ' - INSULATION, RE:SPEC. CONC. FOUNDATION - 3 a° . WALL, RE:STRUCT. CONC. FOUNDATION WALL, 9 _ lj '` I RE:STRUCT. -9 _° ° ° �4 ���C ' m to ARC 7 TYP. TRANSITION DETAIL STUCCO/WOOD A ; = I _ DISCIPLINE STAMP 1 1/2"= 1'-0" FOUNDATION WALL TRANSITION 5/8"GYP. BD. @ SLAB ON GRADE AT GARAGE 1 1 1/2"= 1'-0" R-21 MIN. UNFACED BATT WINDOW PER SCHEDULE, 2 COAT STUCCO SYSTEM INSULATION, RE:SPECRE: SPEC. OVER GALVANIZED FURRED ^\ / WIRE MESH, RE:SPEC 2X6 PT WOOD SILL OVER BACKER R••AND SEALANT � v PT 2X BLOCKING RAINSCREEN SYSTEM LAP DN I lip, FOAM GASKET 5/4"PAINTED WOOD TRIM PRE FINISHED M' AL FLASHING ,Aidge:::::": OVER METAL DRIP FLASHING, I CONTINUOUS BEAD OF SEALAN \ ,_1, 5/8"GYP.BD. RE: SPEC NUDO W'AP -GROUND y 1/2"EXPANSION JOINT, RE:STRU B' ' ER, RE:SPEC R-13 MIN.UNPAGED BATT 4 1" R-5 MIN. FOIL FACED POLYSTYRENE I UNIT DEMISING WALL, RE: - i �' INSULATION, RE:SPEC INSULATION, RE:SPEC IAir 4" CONC.SLAB, RE:STRUCT. PLAN AND PARTITION TYPES WINDOW ELL RE:SPEC: Ji►�- -- 7/8 A0.01 FOR WALL TYPE - 2X4 PT WOOD SILL OVER 7/16"EXTERIOR OSB SHEATHING, W 2" INSULATION BOARD TUFF-N-DRI FOUNDATION DRAINAGE . --_,, ,,;- , :, ,, '._ ���10 FOAM GASKET RE:SYSTEMS BUILT MFR - Z °UNDER SLAB VAPOR BARRIER, 2X6 PT SILL SILL PLATES OVER SYSTEM PROT'CTION BOARD 1/2"EXPANSION JOINT, RE: FOAM GASKET W/ANCHOR $111OVER DRAINAGE 'TT OVER RIGID - i STUCCO J BEAD CLOSER a RE: SPEC. BOLTS, RE:STRUCT INSULA. ION, RE:SPEC. f° a4 ;.a �, STRUCT d ° • GRANULAR FILL, RE:STRUCT. �_, , ' _4 °' 4" CONC.SLAB, RE:STRUCT. r PRE FINISHED METAL FLASHING • • FINISH FLOOR, RE: FLUID APPLIED MEMBRANE .� *���4..����� a • � CONTINUOUS BEAD OF SEALANT FINISH FLOOR, RE: FINISH AIR BAR' ER, RE:SPEC P•�� �����'���a�t �d e ♦ 2 INSULATION BOARD Z SCHEDULE PLAN AND FINISH - =�� � � d a" a �� UNDER SLAB VAPOR BARRIER, 3 I .- - SCHEDULE ■�■■�■■� 3 . II . RE: SPEC. 0 T.O. CONC.@LEVEL 1 ill ° 4"CONCRETE SLAB OVER 10 MIL �t WINDOWWELL `- q VAPOR BARRIER OVER 2" RIGIDN FAIN, RE:CIVIL NUDO WRAP -GROUND > .- - . A ° - •d ���• •��� , GRANULAR FILL,RE:STRUCT. - II - - _ _ - INSULATION OVER GRANULAR , ° Q,_d , ° LOOSE GR' EL, RE: CIVIL ��, BREAKER, RE:SPEC. z ,d. ° . . FILL, RE:STRUCT. - " 8Iiii FINISH FLOOR, RE:FINISH TUFF-N-DRI FOUNDATION DRAINAGE _ •-° ° ° - ° _ - ° ° ° a . �'-�-� °, a__,- ;° ° ° CONS . FOUNDATION = , , gd- '���� SCHEDULE 4 SYSTEM PROTECTION BOARD a �� w L� d. _ ° _ . ° a ��- d-.a '.j.�e;Sjj iEhi01 4-104-� ° b3:1 '-.a °� a n . - = WA. E. TR T. - z= ° '' ' OVER DRAINAGE MATT OVER RIGIDI ► • • • • • • • • ° R S UC INSULATION, RE:SPEC. °. • • • • • • • • • ° a d4 b - - - - °°q 0 0 0 0 0 0 0 0 o NOTE: SEE STRUCUTRAL d 4 a PVC PIPE DISCHARGED ° - : ' At of o� �_■■► I DETAILS FOR INFORMATION -m■■ia 4 ; a- ONTO GR, EL, RE:CIVIL ,. a �_ REGARDING DIMENSIONS, ETC. ��MEEK ;� - ° " °‘ a d I ° ° ^ -. , ° ° 0 °''d. - 4 , . -===, =-arc-ao• c a= cc- FLUIDAPPLIED MEMBRANE AIR ' • PE"IMETER DRAIN _ - NOTE: DETAILS DO NOT BARRIER, RE:SPEC. : _�. '. '. ..,3„-, °. .a .° ° ° __° d; °_ RE. CIVIL - I ° , `° , -' o• - ,d lan. Thri 4.71.14) REFLECT ALL FINISH _ •; - -- ° e a_e -° - MI o 1111t IP 0 0 0 ■ 1 CONC. FOUNDATION _ :A-. a_ I d a - _- — a: a a - qa „ ° _ •°)o- • o• o• • o• o- - - CONDITIONS SEE PLANS AND ° + WALL, RE:STRUCT. FINISH PLANS FOR BUILDING ° d a as 4- _ UoUo �, �� do •o •a•o •o •o •o •o •o •c i4 - - b MATERIALSIIIIII III° i•.•.-.-.< a - ° ° '-,- -% ° , - d °- _ Ia ° '. ISSUE ,'°, _ III I I I I H III HIHI _ —•�•- •c °. ,° aa- - °aq -° ;- ' - ' _ d? ` d = =.,�-d =� °n_ a TOWN OFVAIL PERMIT 10.41110.111110111101/1 d aq e ti d �ai�����. _ S E T ..�.�.�. a =$ I . d a. ° KEY PLAN FOUNDATION WALL TRANSITION WELL ° H III IIIIII III III @ SLAB ON GRADE - GRADE UNIT DEMISING WALL @ SLAB WINDOWI DRAIN 8 1 1/2"= 1'-0" 5 1 1/2"= 1'-0" 2 1 1/2"= 1'-0" 5/8"GYP.BD. 2 COAT STUCCO SYSTEM R-21 MIN.UNFACED BATT OVER GALVANIZED FURRED INSULATION, RE:SPEC FURRING WALL W/ MIN. R-13 WIRE MESH, RE:SPEC UNFACED BATT INSULATION 2X6 PT WOOD SILL OVER Ri NSCREEN SYSTEM LAP DN @ FINISHED SPACE, RE: PLA 0 ER METAL DRIP FLASHING, cw FOAM GASKET Pill \/ RE: SPEC CONTINUOUS BEAD OF SEALANT �1�� 2X4 PT WOOD SILL OVER SHEET TITLE TUFF-N-DRI FOUNDATION - ° FOAM GASKET UNIT DEMISING WALL, RE: 1„ R-5 MIN. FOIL FACED 1/2"EXPANSION JOINT, RE:STRUCT DRAINAGE SYSTEM ' - - FOUNDATION DETAILS PROTECTION BOARD OVER a : �- ° " ' �°� ' - 4" CONC.SLAB, RE:STRUCT. PLAN AND PARTITION TYPES �*� �� 'OLYSTYRENE INSULATION, , DRAINAGE MATT OVER RIGID - ° �� A0.01 FOR WALL TYPE _ RE: SPEC 4" CONC.SLAB, RE:STRUCT. INSULATION, RE:SPEC. ° _ - < 1/Z. . 2" INSULATION BOARD 2X6 PT SILL SILL PLATES OVER - 7/ = EXTERIOR OSB SHEATHING, 2" INSULATION BOARD ° a W UNDER SLAB VAPOR FOAM GASKET W/ANCHOR 1111 RE:SYSTEMS BUILT MFR .I too._ UNDER SLAB VAPOR BARRIER, .VIlt BARRIER, RE:SPEC. BOLTS, RE:STRUCT ZOl'-_ ♦ STUCCO J BEAD CLOSER RE: SPEC. FLUID APPLIED MEMBRANE d ° FINISH FLOOR, RE: AIR BARRIER RE:SPEC. a' A ' PLAN AND FINISH a GRANULAR FILL,RE:STRUCT. �- SCHEDULE PRE FINISHED METAL GRANULAR FILL,RE:STRUCT. `, 1/2"EXPANSION JOINT, RE: _ ;.°q = ♦ p•-_40i _ FLASHING FINISH FLOOR, RE: FINISH d STRUCT. - a a. :" ° FINISH FLOOR, RE: FINISH ., \_ a - °_ °' F - I > %- SCHEDULE REVISION - ° ,, a �� SCHEDULE _ <. �� — T.O.CONC.@LEVEL 1 .. - - 4 CONC. FOUNDATION ° .� CONTINUOUS BEAD OF SEALANT d "�1° - II , _ No. Description Date WALL, RE:STRUCT. — ° ° " 4 ice! ° �I ° m - _1 _ a 1 ASI 001 08-28-2017 m T.O.CONC.@LEVEL 1 - - ! - .� ° ,'. ii, , , , ° A d d 4"CONCRETE SLAB OVER 10 _ ° 1°- c _ Ba d_ MIL VAPOR BARRIER OVER 2" II ° d - d °` \ . . L t' ° L. m FILTER FAB - ° a a • - RIGID INSULATION OVER ���� „,,,,,,,_., „0000 ? 4 "-������� 4” CONC.ENTRY PATIO OVER M��'�� 1�*�.' \ ' o� o" o� oma'o� DC - _ `.° ° , d d ° ° - d ° . - COMP" ANULAR FILL,RE:STRUCT. r��- d° d e �-�-�-�-�-�-�-�- GRANULAR FILL RE'STRUCT •I • PERFORATED ` _ ° Z � ��I • ° , PERIMETE J3E 11L- n ° : ° d 1��11I�����11��'1��1'��'�� ° t-� ° ° TUFF N DRI FOUNDATION �1 aa. • a - I I tillil ti ti 1 - ' ' ° ° . DRAINAGE SYSTEM3 I - - - °'' •, ' ., ; ° : ���o�o�0��o0o�o�o�oo NOTE: SEE STRUCUTRAL ,. � 1=11=� ° ° '° ° °- - .. d.; a, ° ,°+ • • • • • � � � � � d ° '- - �, .I , d ° 'ROTECTION BOARD OVER - P _ I'64.; - 0 - "-°: ,- 4 _ •z z z•4•z j j j j j DETAILS FOR INFORMATION - - -- J - (n c4 ._ - - " - ° - ° a- ° .q 'a. 5'AINAGE MATTOVER RIGID a E I 0 0 0 0 0 0 0 0 0 0 a- d: v � d_ d- a° REGARDING DIMENSIONS, ETC. J oU o oU oU- �'m d- a ;, ° ° • ° io�o�o1�.° a : _ =$ INSULATION, RE:SPEC. o t k ei ° e ° - .. d a - ' _ -°°- - - NOTE: DETAILS DO NOT 1 - - °> - z a a FL D APPLIED MEMBRANE AIR - :' .�o�o�..�o�. ° ° " REFLECT ALL FINISH - - ° ' /404$4.4.4• "°-- ' ° • :' v° -'.,d ' �_; _ . a CONDITIONS- SEE PLANS AND a d�, - , $ BARRIER, RE:SPEC. a E io•o1— Joao.. ° e - ,„ - - d 114• d $ FINISH PLANS FOR BUILDING CONC. FOUNDATION - k R• • °, .° a '' .-°- " 1 '' b ° " - d-m °d ' '' MATERIALS -III III ° le I I 'In-111 III IH IH II I WALL, RE:STRUCT. ° ° ' " IN. d E d ° I PROJECT NUMBER 14054.1 I ° ° 1 1 °III l l .° °iii ISSUE DATE MAY 31, 2017 III I I III III 111 I ' a FOUNDATION WALL TRANSITION SHEET NO. Q FOUNDATION @ FOOTING DEMISING WALL @ STEPPED SLAB @ SLAB ON GRADE - SIDEWALK N 1' 3 A9 . 05 1 1/2"= -0" 0 1 1/2"= 1'-0" 1 1/2"= 1'-0" N