Loading...
HomeMy WebLinkAboutB17-0066_Chamonix_Unit Type 2.2_compliance-report-20170425_135507_427_1493420231.pdf rREScheck Software Version 4.6.4 ' nh Compliance Certificate Project Chamonix Unit 2.2A Energy Code: 2015 IECC Location: Vail, Colorado Construction Type: Multi-family Project Type: New Construction Orientation: Bldg. faces 180 deg. from North Conditioned Floor Area: 1,275 ft2 Glazing Area 11% Climate Zone: 6 (9248 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Chamonix Rd Town of Vail 359 Design Vail, CO 81657 Vail, CO 81657 710 W. Colfax Ave Denver, CO 80204 Compliance: Passes using UA trade-off Compliance: 6.3%Better Than Code Maximum UA: 191 Your UA: 179 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 775 20.0 29.0 0.020 16 South: Wood Frame, 16" o.c. 495 21.0 7.5 0.039 15 Orientation: Front Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 85 0.340 29 Orientation: Unspecified Door 1: Solid 21 0.300 6 Orientation: Unspecified North: Wood Frame, 16" o.c. 420 21.0 7.5 0.039 13 Orientation: Back Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.340 20 Orientation: Back Door 2: Glass 21 0.340 7 Orientation: Back West: Wood Frame, 16" o.c. 100 21.0 7.5 0.039 4 Orientation: Left side East: Wood Frame, 16" o.c. 580 21.0 7.5 0.039 22 Orientation: Right side Window 5: Vinyl/Fiberglass Frame:Double Pane with Low-E 10 0.340 3 Orientation: Unspecified Floor 1: Slab-On-Grade:Unheated 36 10.0 0.684 25 Insulation depth: 4.0' Floor 2: All-Wood Joist/Truss:Over Unconditioned Space 570 30.0 0.0 0.033 19 Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 2 of10 REScheck Software VersionChecklist 4.6.4 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, 'Construction drawings and '❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the La building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies i 103.2, documentation demonstrate EDoes Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ['Not Observable Systems serving multiple ENot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr EDoes Not [PR2]z on loads calculated per ACCA Cooling: Cooling: y, Manual J or other methods ['Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [Foil' ❑ Unheated ❑ Unheated ❑Does Not table for values. to ❑ Heated ❑ Heated [Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft EComplies I See the Envelope Assemblies [FO3]' depth/length. ❑Does Not table for values. L' ['Not Observable j EI Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ElDoes Not insulation and extends a minimum of 6 in. below grade. ['Not Observable ❑Not Applicable Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, :Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 , ❑Not Observable ❑Not Applicable 402.1.1, 1 Glazing U-factor(area-weightedU- U- ❑Complies See the Envelope Assemblies 402.3.1, average). I El Does Not table for values. 402.3.3, 402.3.6, [Not Observable 402.5 : ❑Not Applicable [FR2]1 303.1.3 1U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not tii, with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not tii, ,instructions. ❑Not Observable ; ❑Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 :IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not ;and labeled to indicate <_2.0 cfm ;leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is El Does Not Ca >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and [Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ■❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17] above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 :Protection insulation on HVAC I❑Complies [FR24]1 piping. ❑Does Not fi ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ElComplies [FR18]2 >_R-3. ❑Does Not 0 ❑Not Observable ❑Not Applicable 403.6Automatic or gravity dampers are ❑Complies [FR19] installed on all outdoor air El Does Not intakes and exhausts. [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled '❑Complies [IN13]2 or the installed R-valuesIP ❑Does Not V :provided. [Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood El Does Not table for values. [IN1]1 ❑ Steel ❑ Steel [Not Observable ENot Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ['Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). 111 Steel III Steel ❑Not Applicable 303.2 Wall insulation is installed per 1 ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood EDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel [Not Observable 402.2.6 [FI1]1 ENot Applicable 303.1.1.1, Ceiling insulation installed per 'EComplies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. [Not Observable ❑Not Applicable 402.2.3 :Vented attics with air permeable EComplies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that :extends over insulation. [Not Observable j ❑Not Applicable 402.2.4 Attic access hatch and door R- R- EComplies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. [Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. [Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ['Not Observable tests,verification may need to ENot Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ENot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated EComplies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. [Not Observable ❑Not Applicable 403.1.1 :Programmable thermostats EComplies [F19]2 installed for control of primary ❑Does Not ;heating and cooling systems and :initially set by manufacturer to ENot Observable :code specifications. ❑Not Applicable i 403.1.2 'Heat pump thermostat installed ❑Complies [F110]2 ion heat pumps. ElDoes Not ENot Observable ElNot Applicable 403.5.1 Circulating service hot water qElComPlies [FI11]2 have o ❑Does accessible systems manualautcontrols.maticor. ❑Not ObservableNot ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;All mechanical ventilation system ' 'ElComplies [F125]z fans not part of tested and listed ❑Does Not ail HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]z through one-or two-pipe heating ❑Does Not 441 systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ENot Applicable temperature. 403.5.1.1 :Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ENot Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the iii'occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 'Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL EDoes Not 515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ENot Applicable desired water temperature in the , piping. 403.5.2 Water distribution systems that ;❑Complies [F130]2 have recirculation pumps that ElDoes Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold :water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F13tested tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ;❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for :individual units connected to :three or more showers. i 404.1 '75%of lamps in permanent ❑Complies [F16]' fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ENot Applicable 1 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. '❑Complies [F17F ❑Does Not [Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118P mechanical and water heating ❑Does Not systems have been provided. • [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chamonix Unit 2.2A Report date: 04/25/17 Data filename: P:\00-Project Folders\Chamonix\03-Project Data\01-Code\REScheck\2.2a.rck Page 10 of10 ci. 2015 IECC Energy Efficiency Certificate Insulation Ratin. - - Above-Grade Wall 28.50 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.34 Door 0.34 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments