HomeMy WebLinkAboutB17-0066_E-5_01-01_1498500427.pdf ti or P4f zw- .-3e, GENERAL NO TES -...-, .,, 3 .0 icroJ-a 1. ALL LIGHTING SWITCH LEGS SHALL USE A DEDICATED NEUTRAL WIRE. 06/26/17 2. EC SHALL LABEL ALL ✓-BOXES, RECEPTACLES,AND LIGHTING FIXTURES WITH PANEL AND CIRCUIT NUMBERS, USING 1DYNO TAGS. Residential Standard Calculation Chamonix MECHANICAL EQUIPMENT LOADS UNITS 2. /A&B 3. EC SHALL PROVIDE STAINLESS STEEL COVER PLATES FOR ALL OUTLETS AND SWITCH PLATES. Preliminary Loads Avg Unit Sizing STEP 1 ' Article 220.42 & 220.52 Load 4/27/2017 ELECTRICAL DATA PER PIECE OF EQUIPMENT 4. ALL CONDUIT SHALL RUN PARALLEL TO BUILDING STRUCTURE. Area 1933 General Lighting load 5,799 VA Mike S 970-384-9058 MCA (FLA) 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST ED/T/ONS OF THE RULES, REGULATIONS AND CODES OF THE TOWN STAMP 2 Small Appliance 3,000 VA TAG if MOTOR PHASE VA MOCP NOTES STATE OF COLORADO AND THE LOCAL JURISDICTIONAL AUTHORITY NEC 2014. 1 Laundry circuit 1,500 VA Lighting Calc W 10,299 VA Gross 120V 208V 480V 6. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH ALL OTHER BUILDING TRADES TO ENSURE PROPER INSTALLATION 3,000 VA First 3 kVA@100% OF SYSTEMS SHOWN. 2,555 VA Next 117 kVA @35% B-1 1 X 1 15 PROVIDE DISCONNECT 7. THIS CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS PRIOR TO THE PURCHASE FABRICATION AND INSTALLATION OF 5,555VA Total Lights P-1 1 16-614 5.4 1 648 15 PROVIDE DISCONNECT ANY EQUIPMENT AND SHALL INFORM THE ARCHITECT OR GENERAL CONTRACTOR OF ANY DISCREPANCIES FOR RESOLUTION. STEP 2 Article 220.50 &220.51 Gen.Lgt.,Sm App.& Laun. Demand Load 5,555 VAS ERV-1 1 X 1 23 15 8. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE..THIS CONTRACTOR SHALL COORDINATE WITH THE EXISTING, AND OR NEW, COOLING UNITS HEATING STRUCTURE ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND CEILING TO PROVIDE OFFSETS AS REQUIRED AND 359 2.5TB 1 1587 Total Heat Load 1,587 VA EF-1 2 0.1 1 10.2 - APPROPRIATE VA 2T Total CU Load VA ZONE VALVE CONTROL 1 X 1 15 9. THIS CONTRACTOR SHALL PROVIDE ACCESS TO ALL EQUIPMENT, BOXES, ETC., ABOVE ALL NON-LAY/N CEILINGS AND IN OTHER VA 1T 0 Greater of Heat @ 100% vs.A/C @ 100% 1,587 VA CONCEALED SPACES FOR SERVICING AND MAINTENANCE. D E S I G N 2T TK-1 1 (0.62) 1 75 15 0 1.5T 0 EB-1 1 X 1 400 15 10. ALL EXPOSED WIRING TO BE IN EMT CONDUIT. WRING ABOVE LAY IN CEILINGS SHAL BE IN EMT OR MC TYPE CONDUIT EXPOSED STEP 3 Article 2' 0.53 RACEWAYS IN APPARATUS BAY WITHIN 12' OF FLOOR TO BE RIGID CONDUIT. #each Appliance Load 9,366 VA 11. THIS CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SPATIAL REQUIREMENTS, ACOUSTICAL, THERMAL, AND ELECTRICAL 1 "Water Heater GAS PERFORMANCE CHARACTERISTICS AND COORDINATION OF ALL INSTALLATION REQUIREMENTS FOR EQUIPMENT SUBSTITUTIONS 1 Refrigerator 1,400 VA Dryer Demand Load 6,000 VA MECHANICAL EQUIPMENT LOADS UNITS 2.2A&B FROM THAT DEFINED AS THE BASIS FOR DESIGN. REVIEW AND APPROVAL BY THE DESIGN TEAM DOES NOT ALTER OR MITIGATE 1 'Freezer 900 VA ELECTRICAL DATA PER PIECE OF EQUIPMENT THIS. '-%„.�0 �/�4�%1 1 "Dishwasher 1,400 VA Range Demand Load VA 12. THIS CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME ACQUAINTED WITH EXISTING CONDITIONS. FAILURE TO DO SO L.)1. � F r:6,,,-..,1 t�t� 1 "Disposal 1,176 VA 1/2 HP Unit MCA (FLA) SHALL NOT RELIEVE CONTRACTOR FROM THE RESPONSIBILITY FOR PERFORMING THE WORK. I a /` TAG MOTOR �0 Trash Compactor VA Service Load 22,508 VA # W PHASE VA MOCP NOTES 13. MAINTAIN ALL REQUIRED SERVICE AND ACCESS CLEARANCES REQUIRED BY CODE OR THE MANUFACTURER FOR ALL NEW AND ij , 1 1 Microwave 1,500 VA EXISTING EQUIPMENT. ++• •• = i L---...,:k•�s 0 "Central Vac VA Volts 208 120V 208V 480V ►% kS5/• ..• � ���\aVA1 � 1 Mini Refrigerator 350 VA B-1 1 X 1 15 PROVIDE DISCONNECT 1 "Range hood 762 VA 1/3HP Motor Amps 108 P-1 1 16-614 54 1 648 15 PROVIDE DISCONNECT 0 1 Wine Cooler VA • - DISCIPLINE STAMP 0 1 Ironing Center VA Service 200 AMPS ERV-1 1 X • 1 23 15 ELECTRICAL SPEC/F/CA T/ONS 0 "Jacuzzi Tub VA EF-1 2 0.1 1 10.2 - 0 Humidification VA ZONE VALVE CONTROL 1 X 1 15 GENERAL REQUIREMENTS. 0 Fan Coils VA - 1 Miscellaneous 5,000 VA TK-1 1 (0.62) 1 75 15 SCOPE: 0 Elevator VA EB-1 1 X 1 400 15 0 VA I. FURNISH ALL MATERIALS AND LABOR REQUIRED TO EXECUTE THIS WORK AS INDICATED ON DRAWING AND AS SPECIFIED, AS NECESSARY TO COMPLETE THE CONTRACT ELECTRICAL WORK SHALL INCLUDE, BUT NOT LIMITED TO, 0 VA THESE MAJOR ITEMS: 0 VA Total Appliance Load 12,488 VA A. PROVIDE (2) ELECTRICAL SERVICES AS INDICATED. If 4 or more fixed appliances use 75%demand 9,366 VA R COMPLETE FEEDER(S) INSTALLATION AS REQUIRED FOR NEW AND/OR ELECTRICAL APPARATUS AS SHOWN STEP 4 "Article 220.54 ON SINGLE LINE DIAGRAM. C. COMPLETE CONNECTION OF MOTOR(S), FURNISHED BY OTHERS ilig Electric Clothes Dryers 6,000 VA MECHANICAL EQUIPMENT LOADS UNITS 3.2A&B D. GENERAL POWER DISTRIBUTION , BRANCH CIRCUITS, DEVICES, ETC AS INDICATED. STEP 5 "Article 220.55 E TEST OF ENTIRE SYSTEM AND WORK. PRESENT AT THESE LOCATIONS. ELECTRICAL DATA PER PIECE OF EQUIPMENT Oven W 0 II. PERMITS AND FEES: OBTAIN AND PAY FOR ALL NECESSARY PERMITS, INSPECTIONS, EXAMINATIONS AND FEES OR CHARGES NECESSARY FOR EXECUTION AND COMPLETION OF ELECTRICAL WORK. MOTOR MCA Cooktop W 0 TAG (FLA) Electric Ranges W 1 if WPHASE VA MOCP NOTES Ill. REGULATIONS AND CODES: 120V 208V 480V A. APPLICABLE CODES: NATIONAL ELECTRIC CODE (2014) CONFORM TO THE PREVAILING EDITION AND AMENDMENTS THERETO OF THE LOCAL BUILDING CODES, PERTINENT NFPA PUBLICATIONS AND TO THE REQUIREMENTS OF FEDERAL, Total W STATE OR OTHER CITY AGENCIES HAVING JURISDICTION. Number of appliances 1 Dem. Factor 84%" B-1 1 X 1 15 PROVIDE DISCONNECT Z N Cooktop&Oven Demand Load W IV. SHOP DRAWINGS AND SUBMITTAL: P-1 1 16-614 5.4 1 648 15 PROVIDE DISCONNECT A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ENGINEER REVIEW AND APPROVAL. SHOP DRAWING SUBMITTAL 0 c, SHALL INCLUDE: O ERV-1 2 X 1 23 15 1. PANELBOARD(S). 6 EF-1 3 0.1 1 10.2 - 2. SERVICE PANEL �a ZONE VALVE CONTROL 1 X 1 15 V. CONDUIT AND WIRE:N114 1. A. BRANCH CIRCUIT CONDUCTOR SIZES AND TYPES: USE ONLY COPPER WIRE, TYPE XHHW-2, 600 VOLT N TK-1 1 (0.62) 1 75 15 INSULATION, STRANDED IN SIZES 18 AND LARGER, SOLID IN SIZES /10 AND SMALLER. CONTROL WIRING SHALL BE N EB-1 1 X 1 400 15 /14, STRANDED. E FEEDERS AND SERVICE LINES SHALL BE COPPER OR ALUMINUM XHHW-2 IN PVC CONDUIT BELOW GRADE AND EMT ABOVE GRADE EXCEPT WHERE SUBJECT TO DAMAGE SUBSTITUTE TYPE GRC CONDUIT. N 2. ALL CONDUIT BELOW GRADE SHALL BE SCHEDULE 40 PVC. CONDUIT ABOVE GRADE SHALL BE EMT OR MC CABLE WITH COPPER CONDUCTORS. a' 3. ELECTRICAL DEVICES PER THE NFPA AND LOCAL AUTHORITY HAVING JURISDICTION. a VI. THE WARRANTY SET FORTH FOR THIS SYSTEM SHALL CONSIST OF A FULL THREE (3) YEARS FROM THE DATE OF qi o PROJECT COMPLETION. THE CONTRACTOR WARRANTS THE SYSTEM TO BE FREE OF DEFECTS OF WORKMANSHIP OR PRODUCTS AND WILL INSPECT AND REPAIR THE SYSTEM DURING THIS WARRANTY PERIOD AT NO ADDITIONAL COST TO THE OWNER. co ISSUE 0 Town of Vail Permit Set N ELECTRICAL APPLIANCES N APPLIANCE TAG VOLTAGES AMPS CIRCUIT BREAKER NOTES CONSULTANT a 4 a DISHWASHER DW-1 115 15 DEDICATED CIRCUIT 6SG M 0 a CLOTHES DRYER CD-1 120/208 26 30 DEDICATED CIRCUIT 1 18 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 `1 GARBAGE GD-1 120 14 30 DEDICATED CIRCUIT 970.945. 1004 www.sgm-inc.com O DISPOSAL 0 DRAWN BY: TC co I GAS COOKTOP GC-1 120 15 DEDICATED CIRCUIT CHECKED BY: JG 6 MICROWAVE SHEET TITLE OVEN/KITCHENMW-1 120 11.7 15 DEDICATED CIRCUIT o - HOOD COMBO Electrical Details CLOTHES CW-1 120 26 15 DEDICATED CIRCUIT o WASHER m c h REFRIGERATOR R-1 115 6.5 15 DEDICATED CIRCUIT 0, c REVISION No. Description Date o, k 0 I J t I-- C)U N �I I O .k 0 O 6 O I U I O 0 0 O O I c) U I PROJECT NUMBER 2016-453.001 Lo ISSUE DATE 05/24/17 d- I CO 0 N SHEET NO. 0 E-5 . 01 -01