Loading...
HomeMy WebLinkAboutB17-0066_E-6_02-01_1498500427.pdf oOFk4 zw- i.41-3°eC 0j,1QD716 GENERAL NO TES 06/26/17 1. ALL LIGHTING SWITCH LEGS SHALL USE A DEDICATED NEUTRAL WIRE. 2. EC SHALL LABEL ALL J-BOXES, RECEPTACLES,AND LIGHTING FIXTURES WITH PANEL AND CIRCUIT NUMBERS, USING MECHANICAL EQUIPMENT LOADS UNIT J. 1A&B DYNO TAGS. TOWN STAMP Residential Standard Calculation Chamonix Preliminary Loads Avg Unit Sizing ELECTRICAL DATA PER PIECE OF EQUIPMENT 3. EC SHALL PROVIDE STAINLESS STEEL COVER PLATES FOR ALL OUTLETS AND SWITCH PLATES. STEP 11 Article 220.42 & 220.52 Load 4/27/2017 4. ALL CONDUIT SHALL RUN PARALLEL TO BUILDING STRUCTURE. Area 1933 General Lighting load 5,799 VA Mike S 970-384-9058 TAG MOTOR Area (FLA) PHASE VA MOCP NOTES 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITIONS OF THE RULES, REGULATIONS AND CODES OF THE 2 Small Appliance 3,000 VA W STATE OF COLORADO AND THE LOCAL JURISDICTIONAL AUTHORITY NEC 2014. 1 Laundry circuit 1,500 VA Lighting Calc 120V 208V 480V 10,299 VA Gross 6. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH ALL OTHER BUILDING TRADES TO ENSURE PROPER INSTALLATION 3,000 VA First 3 kVA@100% B-1 1 X 1 15 PROVIDE DISCONNECT OF SYSTEMS SHOWN. 359 2,555 VA Next 117 kVA @35% P-1 1 16-614 X 1 648 15 PROVIDE DISCONNECT 7 THIS CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS PRIOR TO THE PURCHASE FABRICATION AND INSTALLATION OF 5,555VA Total Lights ANY EQUIPMENT AND SHALL INFORM THE ARCHITECT OR GENERAL CONTRACTOR OF ANY DISCREPANCIES FOR RESOLUTION. ERV-1 2 X 1 23 15 DESIGN STEP 2 Article 220.50 & 220.51 Gen.Lgt.,Sm App.& Laun. Demand Load 5,555 VA" • • • 8. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE..THIS CONTRACTOR SHALL COORDINATE WITH THE EXISTING, AND OR NEV, COOLING UNITS HEATING EF-1 3 0. 1 1 10.2 - STRUCTURE ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND CEILING TO PRO I4DE OFFSETS AS REQUIRED AND 2.5TB-1 1587 Total Heat Load 1,587 VA ZONE VALVE CONTROL 1 X 1 15 APPROPRIATE VA 2T Total CU Load VA TK-1 1 (0.62) 1 75 15 9. THIS CONTRACTOR SHALL PROVIDE ACCESS TO ALL EQUIPMENT, BOXES, ETC., ABOVE ALL NON-LAYIN CEILINGS AND IN OTHER VA 1T 0 Greater of Heat @ 100% vs.A/C @ 100% 1,587 VA CONCEALED SPACES FOR SERVICING AND MAINTENANCE. 2T 0 EB-1 1 X 1 400 15 - 1 1.5T10. ALL EXPOSED WIRING TO BE IN EMT CONDUIT. WIRING ABOVE LAY IN CEILINGS SHAL BE IN EMT OR MC TYPE CONDUIT EXPOSED --;,.$0 L/ !% STEP 3 Article 2'20 53 0 RACEWAYS IN APPARATUS BAY WITHIN 12' OF FLOOR TO BE RIGID CONDUIT fl�, •Ft. �N,��ti #each Appliance Load 9,366 VA 11. THIS CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SPATIAL REQUIREMENTS, ACOUSTICAL, THERMAL, AND ELECTRICAL ;4-01 \ems'_ ��i`1 'Water Heater GAS PERFORMANCE CHARACTERISTICS AND COORDINATION OF ALL INSTALLATION REQUIREMENTS FOR EQUIPMENT SUBSTITUTIONS o • rFROM THAT DEFINED AS THE BASIS FOR DESIGN. REVIEW AND APPROVAL BY THE DESIGN TEAM DOES NOT ALTER OR MITIGATE �J� L 1 1 Refrigerator 1,400 VA Dryer Demand Load 6,000 VA THIS. +f• ,. 1 'Freezer 900 VA ��� $/` C��_� 1 'Dishwasher 1,400 VA Range Demand Load VA" 12 THIS CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME ACQUAINTED WITH EXISTING CONDITIONS. FAILURE TO DO SO \�1VA1 ' 1 Disposal 1,176 VA 1/2 HP Unit SHALL NOT RELIEVE CONTRACTOR FROM THE RESPONSIBILITY FOR PERFORMING THE WORK. 0 Trash Compactor VA Service Load 22,508 VA 13. MAINTAIN ALL REQUIRED SERVICE AND ACCESS CLEARANCES REQUIRED BY CODE OR THE MANUFACTURER FOR ALL NEW AND DISCIPLINE STAMP 1 'Microwave 1,500 VA EXISTING' EQUIPMENT. 0 'Central Vac VA Volts 208 1 'Mini Refrigerator 350 VA 1 'Range hood " 762 VA 1/3HP Motor Amps 108 0 'Wine Cooler " VA 0 'Ironing Center VA Service 200 AMPS ELECTRICAL SPEC/F/CA T/ONS 0 'Jacuzzi Tub VA 0 Humidification VA 0 Fan Coils VA GENERAL REQUIREMENTS. 1 Miscellaneous 5,000 VA SCOPE. 0 Elevator VA 0 VA I. FURNISH ALL MATERIALS AND LABOR REQUIRED TO EXECUTE THIS WORK AS INDICATED ON DRAWING AND AS SPECIFIED, AS NECESSARY TO COMPLETE THE CONTRACT ELECTRICAL WORK SHALL INCLUDE, BUT NOT LIMITED TO, ilig 0 VA THESE MAJOR ITEMS: 0 VA Total Appliance Load 12,488 VA A. PROVIDE (2) ELECTRICAL SERVICES AS INDICATED. If 4 or more fixed appliances use 75%demand 9,366 VA B. COMPLETE FEEDER(S) INSTALLATION AS REQUIRED FOR NEW AND/OR ELECTRICAL APPARATUS AS SHOWN STEP 4 Article 220.54 ON SINGLE LINE DIAGRAM. Electric Clothes Dryers 6,000 VA C. COMPLETE CONNECTION OF MOTOR(S), FURNISHED BY OTHERS D. GENERAL POWER DISTRIBUTION , BRANCH CIRCUITS, DEVICES, ETC AS INDICATED. STEP 5 "Article 220.55 E. TEST OF ENTIRE SYSTEM AND WORK. PRESENT AT THESE LOCATIONS. MECHANICAL EQUIPMENT LOADS UNIT JL.2A&B II. PERMITS AND FEES: OBTAIN AND PAY FOR ALL NECESSARY PERMITS, INSPECTIONS, EXAMINATIONS AND FEES OR Oven W 0 CHARGES NECESSARY FOR EXECUTION AND COMPLETION OF ELECTRICAL WORK. Z o Cooktop W 0 ELECTRICAL DATA PER PIECE OF EQUIPMENT Electric Ranges W 1 ///. REGULATIONS AND CODES: O o TAG MCA (FLA) A. APPLICABLE CODES: NATIONAL ELECTRIC CODE (2014) CONFORM TO THE PREVAILING EDITION AND AMENDMENTS # MOTOR PHASE VA MOCP NOTES THERETO OF THE LOCAL BUILDING CODES, PERTINENT NFPA PUBLICATIONS AND TO THE REQUIREMENTS OF FEDERAL, Total W W STATE OR OTHER CITY AGENCIES HAV/NG JURISDICTION. Number of appliances 1 Dem. Factor 84%12OV 208V 48OV N Cooktop&Oven Demand Load W IV. SHOP DRAWINGS AND SUBMITTAL: 114 B-1 1 X 1 15 PROVIDE DISCONNECT A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ENGINEER REVIEW AND APPROVAL. SHOP DRAWING SUBMITTAL o SHALL INCLUDE: N P-1 1 16-614 5.4 1 648 15 PROVIDE DISCONNECT 1. PANELBOARD(S). 2. SERVICE PANEL ERV-1 2 X 1 23 15CI) N V. CONDUIT AND WIRE: EF-1 3 0. 1 1 10.2 - 1. A. BRANCH CIRCUIT CONDUCTOR SIZES AND TYPES: USE ONLY COPPER WIRE, TYPE XHHW-2, 600 VOLT ZONE VALVE CONTROL 1 X 1 15 INSULATION, STRANDED IN SIZES 18 AND LARGER, SOLID IN SIZES 110 AND SMALLER. CONTROL WIRING SHALL BE /14, STRANDED. TK-1 1 (0.62) 1 75 15 B. FEEDERS AND SERVICE LINES SHALL BE COPPER OR ALUMINUM XHHW-2 IN PVC CONDUIT BELOW GRADE AND O EMT ABOVE GRADE EXCEPT WHERE SUBJECT TO DAMAGE SUBSTITUTE TYPE GRC CONDUIT. g. EB-1 1 X 1 400 15 2. ALL CONDUIT BELOW GRADE SHALL BE SCHEDULE 40 PVC. CONDUIT ABOVE GRADE SHALL BE EMT OR MC CABLE E WITH COPPER CONDUCTORS. a O 3. ELECTRICAL DEVICES PER THE NFPA AND LOCAL AUTHORITY HAVING JURISDICTION. ISSUE ci NVI. THE WARRANTY SET FORTH FOR THIS SYSTEM SHALL CONSIST OF A FULL THREE (3) YEARS FROM THE DATE OF Town of Vail Permit Set o PROJECT COMPLETION. THE CONTRACTOR WARRANTS THE SYSTEM TO BE FREE OF DEFECTS OF WORKMANSHIP OR N PRODUCTS AND WILL INSPECT AND REPAIR THE SYSTEM DURING THIS WARRANTY PERIOD AT NO ADDITIONAL COST TO ,, THE OWNER. N- (N CONSULTANT 4 ELECTRICAL APPLIANCES 6SG M 0 APPLIANCE TAG VOLTAGES AMPS CIRCUIT BREAKER NOTES 1 18 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 1,J DISHWASHER OW-1 115 15 DEDICATED CIRCUIT 970.945. 1004 www.sgm-inc.com 000 T DRAWN BY: TC m I CLOTHES DRYER CD-1 120/208 26 30 DEDICATED CIRCUIT k CHECKED BY: JG GARBAGE SHEET TITLE DISPOSAL GD-1 120 14 30 DEDICATED CIRCUIT Electrical Details o GAS COOKTOP GC-1 120 15 DEDICATED CIRCUIT m MICROWAVE o OVEN/KITCHEN MW-1 120 11.7 15 DEDICATED CIRCUIT h HOOD COMBO CLOTHES CW-1 120 26 15 DEDICATED CIRCUIT s WASHER REVISION REFRIGERATOR R-1 115 6.5 15 DEDICATED CIRCUIT No. Description Date o, k 0 I J U 1 I O .k C 1 0 U I 'c 'S O O I c) U I PROJECT NUMBER 2016-453.001 in Lo ISSUE DATE 05/24/17 d- 1 CO 0 N SHEET NO. CS E-5 . O1 -08