B17-0066_FP304_1498500437.pdf
Zi; x 1. his ' igin 101 06/26/17 ° , IP �' - - L . 6 6- I IN I I O O O - HALLWAY OSB/CO 1 ® fTOWN STAMP FIRE PROTECTION LEGEND = MAX 20'THROW. ® O SYMBOL DEVICE DESCRIPTION I i ii' I - ®SB u KITCHEN 359 H O SPRINKLER HEAD - STANDARD UPRIGHT, CHROME 0 I I O LAUNDRY ® BEDROOM 2 <�I SPRINKLER HEAD - CONCEALED PENDENT, WHITE __ ® 0 1-1/2" WATER LINE IN I I r REF CIVIL/MEP PLANS i E ] _I N P ® SPRINKLER HEAD - CONCEALED SIDEWALL, WHITE I I - 0 BATH 2 CAR GARAGE i i D E S I G N L COBATH0 y ® SPRINKLER HEAD - DRY SIDEWALL WATER ERTRY I- -UP DN '-' 0 I F°— °Div O ® O L - J Sprinkler Pipe ® '`' N- —I I °0 j ° O ..� DINING CLOSET I I I SB/CO — CLOSET ,00ir�r••. NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE � II ,� O E EIGi SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND L J _ 0 ,VEIL k•' ..•'•. ENGINEER. COORDINATE TYPE AND FINISH WITH INTERIORS. HEADS SHALL OO �`� 1;i- ;r 15"- BE LISTED FOR RESIDENTIAL USE IN RESIDENTIAL UNITS. ALL HEADS SHALL CLOSET '=� SB .�•�Q' ;: ml BE QUICK RESPONSE. I O 0 0 1 $: MECHrJ233 rre; 1 ENTRY = 'r6 • K fir. ® • tit 1QN,4L ,r' O OSB/CO BEDROOM Ai _ •*....,..••••• LIVING titbiss —® L� E� 0 _ FIRE ALARM LEGEND: — o / 84 SYMBOL DEVICE DESCRIPTION MASTER 0 '-� I ittWit‘ BEDROOM FACP - - O. MASTER BATH Fire Alarm Control Panel OSB Eh id - KEY Fire Alarm Keypad/Annunciator C : 11 L mi 0 0 L, Sprinkler Waterflow Switch 14 Ul }T, Sprinkler Valve Tamper Switch L L OSB Smoke Detector w/Sounder Base - Multisensor Device, Smoke & OSB/C0 Carbon Monoxide Detector w/Sounder Base z UNIT 3.2 A - LEVEL 01 - RCP - _ - - o FIRE PROTECTION NOTES: 2 UNIT 3.2 ALEVEL 02 RCP UNIT 3.2 ALEVEL 03RCP2 1/4" = 1' 0" 2 1/4" = 1' 0" 2 1/4" = 1' 0" 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13D AND a VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. I 2. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND V ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER SYSTEM DESIGN AND INSTALLATION. I T--I r EL' EF 3. PROVIDE FREEZE PROTECTION WHERE NECESSARY. I I ; 1 I ii,, ,,_ hl , Fllg___ ) 4. PER NFPA 13D, CLOSETS LESS THAN 3' IN DEPTH AND II \ O HALLWAY UNDER 24 SQUARE FEET ARE NOT PROVIDED WITH SPRINKLER 7 1 �" ;_ rt_�' ® SB/CO ISSUE COVERAGE. r — - F I - - MAY 24, 2017 TOWN OF 5. PER NFPA 13D, BATHROOMS UNDER 55 SQUARE FEET IN 1 ; MAX 2o'THROW. 0 - ti, AREA ARE NOT PROVIDED WITH SPRINKLER COVERAGE. ® VAIL PERMIT SET N BEDROOM 2 11 6. PER VFES, GARAGES SHALL BE SPRINKLERED. _ ; KI CHEN SB KEY PLAN ® 1 ATH — — 11 7. EACH TOWNHOUSE UNIT WILL BE SERVED BY A SINGLE L < 5 SQ FT LAUNDRY 1 -1/2" SPRINKLER LINE. I 1 L 7 J ' '7/ L 1 1-1/2" WATER LINE IN II 1 I 1 REF CIVIL/MEP PLANS I I ] - 1 1 a T 8. THE FIRE PROTECTION SYSTEM SHALL BE STANDARD WET L 1 - - I 1 PIPE. FREEZE PROTECTION SHALL BE COORDINATED. I / SPRINKLER ASSEMBLY WITH L o �/ BACKFLOW PREVENTER, FLOW/TAMPER. - - I ,�, / 9. SPRINKLER HEADS MUST BE INSTALLED AT LEAST 3' FROM 1 _-�/ UPL J.° I )sII I CLOSET ISI �® CEILING FAN MOTOR CASINGS. c, WATER ENTRY 2 CAR GARAGE © t!' DINING BATH r 10. CONSTRUCTION/INSTALLATION SHALL BE PER FIRE PROTECTION `--&-4 �s> <55 SQ T CLOSET CONTRACTOR'SSB/CO SHEET TITLE SHOP DRAWINGS. THESE PLANS ARE FOR REFERENCE ONLY. } * _ FIRE ALARM NOTES : ,-] CLOSET al UNIT3.2A - FIRE &2'-FT-DEEP- MECH ,NILE • C 4 PROTECTION & FIRE 1 . FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 V ® ALARM AND VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. 1 , , .a C , ,____ 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM SB/CO 2 CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, ENTRY '�' '=' LIVING © MASTER © REVISION SYSETM DESIGN AND INSTALLATION. - BEDROOM J - BEDROOM n. - N I OSB OSB 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE 2 cii TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. `'' IIIiII 3 a =4. PROVIDE CARBON MONOXIDE DETECTION PER COLORADOI MASTER BATH II Z STATE LAW, NFPA 720 AND VFES REQUIREMENTS. _ _ 1 02 _ ,F o I 5. EACH TOWNHOUSE UNIT SHALL HAVE A DEDICATED FIRE r ° ° L r ALARM CONTROL PANEL TO SUPERVISE SMOKE AND CO 1 DETECTORS AS WELL AS THE FIRE SPRINKLER SYSTEM. o m 6. SMOKE DETECTORS MUST BE INSTALLED AT LEAST 3' AWAY FROM CEILING FAN BLADES. ❑ ❑ a N 7. FIRE ALARM SYSTEM INSTALLATION WILL OCCUR ON SITE IN VAIL. MODULAR CONSTRUCTION WILL INCLUDE BOXES AND D PATHWAYS. 4 UNIT 3.2 A - LEVEL 01 - FLOOR PLANUNIT 3.2 A - LEVEL 02 - FLOOR PLAN UNIT 3.2 A - LEVEL 03 - FLOOR PLAN [PROJECT NUMBER PROJECT NUMBER 1/4" = 1'-0" 1 1/4" = 1'-0" 1 1/4" = 1'-0" [ISSUE DATE MAY 24, 2017 2 a cp SHEET NO. a N 0N FP3.04 N N