HomeMy WebLinkAboutB17-0066_FP305_1498500430.pdf z X lb IS iQ071�c 06/26/17 1-1/2" WATER LINE IN REF CIVIL/MEP PLANS SPRINKLER ASSEMBLY WITH 7 BACKFLOW PREVENTER, FLOW/TAMPER. O Y Y = Iii IF Oi 'er ' 1 I DEN/ DINING I TOWN STAMP FIRE PROTECTION LEGEND: SUNROOM a) I SYMBOL DEVICE DESCRIPTION WATER ENTRY 0 0 (z 0 SB aLO CL• 0_ i._0_6_, • O SPRINKLER HEAD - STANDARD UPRIGHT, CHROME 1 O i ® . e . 174 ® lbe . i , 3 5 9 0 €1 SPRINKLER HEAD - CONCEALED PENDENT, WHITE u 0 - } U DN h ori ® SPRINKLER HEAD - CONCEALED SIDEWALL, WHITE --4P--1 1044 - BN _ IIi _ O BEDROOM1 LINEN BEDROOM2 2 DESIGN 0 ® SPRINKLER HEAD - DRY SIDEWALL 0 SB © I N ___Li Sprinkler Pipe 0 _ I OSB/CO OO 0 O ® O NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE CO HALLWAY I IT f, �� '., SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND c - ' •,="•k•� . ENGINEER. COORDINATE TYPE AND FINISH WITH INTERIORS. HEADS SHALL - - - L = .e 0%.VEIG/A: `.p BE LISTED FOR RESIDENTIAL USE IN RESIDENTIAL UNITS. ALL HEADS SHALL KITCHEN ® '-�ly� mS BE QUICK RESPONSE. Q © 0 : �; 35233 i �i,r '' 0 I LAUNDRY BATH "0 `� . - W � — ', WP � i O (€' ® 0 .-.....ss...„'-►errA1--c,.• ,, 2 CAR GARAGE MASTER L 0 0 CLOSET FIRE ALARM LEGEND: ® 1� SYMBOL DEVICE DESCRIPTION L 0 0 - ®SB FACP Fire Alarm Control Panel ENTRY MECH 0 O f 0 0 I KEY = Fire Alarm Keypad/Annunciator OSB/C0 @ O I %lite — 0 © O SB/CO 0 ® MASTER BATH — }-�-y Sprinkler Waterflow Switch I LIVING `•' ® 0 a (�QQ POWDER t]", Sprinkler Valve Tamper Switch ® 0 0 CLOSET - MASTER ,, , BEDROOM ®SB Smoke Detector w/Sounder Base E N,� N a � ,� O Multisensor Device, Smoke & O O . % J , O O SB/C0 Carbon Monoxide Detector w/Sounder Base Z — 2 UNIT 3L.2 A - LEVEL 01 - RCP - - - - 0 UNIT 3L.2 ALEVEL 02RCP UNIT 3L.2 ALEVEL 03RCP 1/4" = 1' 0" 2 1/4" = 1'-0" 2 1/4" = 1'-0" _ FIRE PROTECTION NOTES: a 1 . SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13D AND I VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. 1-1/2" WATER LINE IN SPRINKLER ASSEMBLY WITH Cii) 2. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND REF CIVIL/MEP PLANS ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE BACKFLOW PREVENTER, FLOW/TAMPER. PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER - SYSTEM DESIGN AND INSTALLATION. P - s iI 1� II I - 3. PROVIDE FREEZE PROTECTION WHERE NECESSARY. DEN/ I SUNROOM © Clio 132 CIT�O 4. PER NFPA 13D, CLOSETS LESS THAN 3' IN DEPTH AND WATER ENTRY &24 SQ FT ISSUE CUNDER 24 OVERAGE. SQUARE FEET ARE NOT PROVIDED WITH SPRINKLER - IT) DINING OSB MAY 24, 2017 TOWN OF tz, <3'FT BEEP 5. PER NFPA 13D, BATHROOMS UNDER 55 SQUARE FEET IN 0 `-�-, &245{.IFT VAIL PERMIT SET AREA ARE NOT PROVIDED WITH SPRINKLER COVERAGE. �J BEDROOM 1 PDN s BEDROOM 2 KEY PLAN 6. PER VFES, GARAGES SHALL BE SPRINKLERED. v ® S I 1 R kP—oT -T—T-7 _i W DN II 7. EACH TOWNHOUSE UNIT WILL BE SERVED BY A SINGLE 1 o 7 LINEN 1 -1/2" SPRINKLER LINE. co 1 <3'FT DEEP SB 8. THE FIRE PROTECTION SYSTEM SHALL BE STANDARD WET © I L &24 SQ FT PIPE. FREEZE PROTECTION SHALL BE COORDINATED. - —� – I ® ®III o>, C. 111 I I I <H . 9. SPRINKLER HEADS MUST BE INSTALLED AT LEAST 3' FROM +II I HALLWAY Iul CEILING FAN MOTOR CASINGS. -IIIH HI I I I TBATH III r- 1 4o ' — O j0 i <55 SQ FT SHEET TITLE 10. CONSTRUCTION/INSTALLATION SHALL BE PER FIRE PROTECTIONS + �� UNIT 3L.2 A - FIRE CONTRACTOR'S SHOP DRAWINGS. THESE PLANS ARE FOR + KITCHEN REFERENCE ONLY. II MASTER FIRE ALARM NOTES: . ® 2CARGARAGE + 7 1 1 CLOSET r PROTECTION & FIRE T „ © LAUNDRY ALARM 1 . FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 AND VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. T u 1! E 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ® ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM �� ^ ®SB REVISION ii CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, MECH / 11 SYSETM DESIGN AND INSTALLATION. 2 O zn 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE •s TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. OSB/C0 x� / UP '-° SVCO P ' c 4. PROVIDE CARBON MONOXIDE DETECTION PER COLORADO -4 LIVING 2 STATE LAW, NFPA 720 AND VFES REQUIREMENTS. C) ® 1:-. , if [ 5. EACH TOWNHOUSE UNIT SHALL HAVE A DEDICATED FIRE — CLOSET MASTER BATH MASTER ALARM CONTROL PANEL TO SUPERVISE SMOKE AND CO ENTRY &24 SQ FT <55 SQ FT o o o i BEDROOM o DETECTORS AS WELL AS THE FIRE SPRINKLER SYSTEM. — POWDER 6. SMOKE DETECTORS MUST BE INSTALLED AT LEAST 3' AWAY - ��' 'i FROM CEILING FAN BLADES. D 7. FIRE ALARM SYSTEM INSTALLATION WILL OCCUR ON SITE IN a VAIL. MODULAR CONSTRUCTION WILL INCLUDE BOXES AND PATHWAYS. 4 UNIT 3L.2 A - LEVEL 01 - FLOOR PLANUNIT 3L.2 A - LEVEL 02 - FLOOR PLAN UNIT 3L.2 A - LEVEL 03 - FLOOR PLAN [PROJECTNUMBER PROJECT NUMBER 1/4" = 1'-0" 1 1/4" = 1'-0" 1 1/4" = 1'-0" ISSUE DATE MAY 24, 2017 2 a SHEET NO. a N FP3.05 1.1 N N