Loading...
HomeMy WebLinkAboutB17-0066_G0-00-01_1498500431.pdf 10 OF lb, z le we PROJECT LOCATION I 1"=400' O .)-1121:1111115-)3121 11 06/26/17 cHAmoNix . vAIL , ...;::rr .. ,,,,,,g;r:41-!'" ' ,-\ EOM ' _ 2310 CHAMONIX RD VAIL, PROJECT SITE \ � J' �4 ." TOWN STAMP .410L' 1.411111111~11014, . , COLORADO 81657 _t 70 -_-:' _.,k7 TOWN OF VAIL 3 5 9 - /F ' am F , ,u ,vim - _� c [1 .i �` ;,- a. n'e: •Po• �.,.. y 1 ,. ' W.,, ,,,./z, , ...1..!< ter'. �P�F, 0 ./.-- ,<, /. ..,,'•; - '4V... PERMIT SET DESIGN . ,.. r cL____., ,{4, n/' r { BUILDING 01 �, � Cit �► , . . . . . ill tlfrl .'• PROJECT TEAM GENERAL NOTES INDEX OF DRAWINGS B-25 ARCHITECTURE-BUILDING 01 FIRE PROTECTION f Arc ARCHITECTURE/INTERIORS MEP GEOTECHNICAL 1. DO NOT SCALE DRAWINGS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL � . SCALE DETAILS. SPECIFICATIONS GOVERN ALL. SHEET NUMBER SHEET NAME SHEET NUMBER SHEET NAME DISCIPLINE STAMP 359 DESIGN, LLC SGM ENGINEERS CESARE,INC. 2. CONTRACTOR TO ISSUE COMPLETE SET OF CONTRACT DOCUMENTS TO EACH 710 WEST COLFAX AVENUE 118 W SIXTH ST,SUITE 200 P.O. BOX 23052 SUBCONTRACTOR FOR COORDINATION OF WORK AND DESCRIPTION OF SCOPE G0.00-01 TITLE SHEET-BUILDING 01 FP3.01 UNIT 2.1 A-FIRE PROTECTION&FIRE ALARM DENVER,COLORADO 80204 GLENWOOD SPRINGS,CO 81601 CONTACT: IAN CESARE 3. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS G0.01-01 CODE STUDY CONTACT:WILLIAM HENTSCHEL CONTACT: MIKE SUHRBIER PHONE:(303)520-1420 FP3.02 UNIT 2.2 A-FIRE PROTECTION&FIRE ALARM WHENTSCHEL@359ARCH.COM PHONE: (970)384-9032 SPECIFIED. WHERE THE TERM "OR EQUAL" IS USED THE ARCHITECT ALONE SHALL CIVIL FP3.03 UNIT 3.1 A-FIRE PROTECTION&FIRE ALARM PHONE: (303)884-9131 DETERMINE EQUALITY BASED ON INFORMATION SUBMITTED BY THE CONTRACTOR. FP3.04 UNIT 3.2 A-FIRE PROTECTION&FIRE ALARM 4. REFER TO STRUCTURAL DRAWINGS FOR ALL REINFORCING. SHEET NUMBER SHEET NAME FP3.05 UNIT 3L.2 A-FIRE PROTECTION&FIRE ALARM 5. ARCHITECTURAL, MECHANICAL, ELECTRICAL,AND NON-STRUCTURAL SYSTEMS, CIVIL DEVELOPER GENERAL CONTRACTOR COMPONENTS AND ELEMENTS PERMANENTLY ATTACHED TO STRUCTURES, C100 GRADING PLAN INCLUDING SUPPORTING STRUCTURES AND ATTACHMENTS AND NON-BUILDING C101 GRADING PLAN CONT'D MARTIN/MARTIN,INC. TRIUMPH DEVELOPMENT R.A. NELSON STRUCTURES THAT ARE SUPPORTED BY OTHER STRUCTURES, SHALL MEET THE C102 GRADING PLAN CONT'D 0101 FAWCETT RD UNIT 260 12 VAIL ROAD SUITE 700 51 EAGLE ROAD#2 P.O. DRAWER 5400 REQUIREMENTS PER 2009 IBC CHAPTER 16 AND ASCE 7-02 SECTION 9.6 C104 GRADING DETAILS PO BOX 8896 VAIL,CO 81657 AVON,CO 81620 COORDINATE DESIGN WITH ARCHITECT AND ENGINEER OF RECORD. C106 UTILITY SITE WALLS AVON,CO 81620 CONTACT: MICHAEL O'CONNOR CONTACT: MIKE CUTHBERTSON CONTACT: MASON TALKINGTON, PE MICHAEL@TRIUMPHDEV.COM MCUTHBERTSON@RANELSON.COM 6. STUCCO ASSEMBLY REQUIRES (2)AIR INFILTRATION LAYERS AS A BOND BREAK C200 OVERALL UTILITY PLAN PHONE: (970)926-6007 PHONE: (970)688-5057 PHONE:(970)748-7662 BETWEEN THE WALL ASSEMBLY AND THE STUCCO APPLICATION. C213 PERIMETER DRAIN PLAN C214 PERIMETER DRAIN PLANlig I LANDSCAPE LANDSCAPE OWNER STRUCTURAL SYMBOLS MATERIALS SHEET NUMBER SHEET NAME OUTSIDE LA COMMUNITY DEVELOPMENT SGM ENGINEERS L1.00 LANDSCAPE MASTER PLAN 2623 BURGESS CREEK ROAD CONTACT:GEORGE RUTHER,AICP 118 W SIXTH ST,SUITE 200 STEAMBOAT SPRINGS,CO 80487 GRUTHER@VAILGOV.COM GLENWOOD SPRINGS,CO 81601 L1.01 LANDSCAPE PLAN WEST CONTACT:SANDI GIBSON PHONE: (970)479-2145 CONTACT:JOHN E.PARTCH MIKE SUHRBIER L1.02 LANDSCAPE PLAN EAST OSLA@ME.COM PHONE: (970)-384-9032 ROOM NAME ROOM °- a L2.00 LANDSCAPE NOTES&DETAILS XXXXX NAME/NUMBER - ' . 'a CONCRETE/PRECAST IR1.01 IRRIGATION PLAN _ CONCRETE IR2.01 IRRIGATION DETAILS EXISTING COLUMN Z SYSTEMS BUILT MANUF. SPEC WRITER © CENTERLINE -III- ARCHITECTURE-BUILDING 01 SOIL SHEET NUMBER SHEET NAME 0 NASHUA BUILDERS ARCHITECTURAL SPECIFICATION WRITER 5200 S. FEDERAL WAY CONTACT: MARIA STONE BOISE,ID 83716 STONEMARIA@Q.COM © COLUMN _- A0.01 STANDARD PARTITIONS&EXTERIOR ASSEMBLIES 5 CONTACT: SHAIN ZENOR PHONE: (303)681-3611 CENTERLINE SAND, EIFS FINISH A0.04 ARCHITECTURAL SITE PLAN SZENOR@NASHUABUILDERS.COM - _ ":- PHONE: (208)345-0222 COAT A2.01-01 BUILDING 01 -FLOOR PLANSlig \ ACCESSORY \ \ A2.02-01 BUILDING 01-FLOOR PLANS X \ A3.01-01 BUILDING 01-UNIT 2.1 A-LEVEL 01 \ BRICK A3.02-01 BUILDING 01-UNIT 2.1 A-LEVEL 02 A3.03-01 BUILDING 01-UNIT 3.2 A-LEVEL 01 ODEMOLITION A3.04-01 BUILDING 01 -UNIT 3.2 A-LEVEL 02 1 NUMBERED NOTES A3.05 01 BUILDING 01 -UNIT 3.2 A-LEVEL 03 CMU A3.06-01 BUILDING 01 -UNIT 2.2 A-LEVEL 01 • • A3.07-01 BUILDING 01-UNIT 2.2 A-LEVEL 02 DRAWING ABBREVIATIONS01 SBUILDING ECTION WALL A3.08-01 BUILDING 01-UNIT 2.2 A-LEVEL 03 AO.X STONE A4.01-01 BUILDING 01 -ELEVATIONS A5.01-01 BUILDING 01 -SECTIONS A5.02-01 BUILDING 01 -SECTIONS A6.01 INTERIOR INTERIOR ELEVATIONS ELEVATIONS&&STAIRS STAIRS UNIT-UNIT 2.1 2.2 AB ANCHOR BOLT FIBERGLASS BATT ISSUE ACT ACOUSTICAL TILE CEILING MEM MEMBRANE A6.02_ AFF ABOVE FINISH FLOOR MFR MANUFACTURER AO.X ELEVATION INSULATION A6.04 INTERIOR ELEVATIONS&STAIRS-UNIT 3.2 TOWN OF VAIL PERMIT ALUM ALUMINUM MIN MINIMUM X A6.06 INTERIOR SCHEDULES AP ACCESS PANEL MR MOISTURE RESISTANT A6.07 INTERIOR DETAILS SET APPROX APPROXIMATE MTL METAL XPS RIGID INSULATION A8.01-01 WINDOW AND DOOR-SCHEDULES ARCH ARCHITECTURE NIC NOT IN CONTRACT I� A8.02 WINDOW AND DOOR-TYPICAL DETAILS ASSOC ASSOCIATED NO NUMBER BD BOARD NOM NOMINAL • 01 SECTION DETAIL A9.02 ROOF DETAILS KEY PLAN BLDG BUILDING NTS NOT TO SCALE AO.X - ,•-. A9.04 DEMISING WALL DETAILS BLK BLOCK OA OVERALL X FOIL FACED POLYISO A9.05 FOUNDATION DETAILS BO BOTTOM OF OAM OVERALL MASONRY RIGID INSULATION A6.08 INTERIOR DETAILS BOT BOTTOM OC ON CENTER 01 BRG BEARING OH OVERHEAD r AO.X� A9.01 EXTERIOR DETAILS BSMT BASEMENT ORD OVERFLOW ROOF DRAIN 1 I X PLAN, BLOW-UP ccSPF- CLOSED CELL A9.03 PLAN DETAILS CJ CONTROL JOINT OS OVERFLOW SCUPPER Li DETAIL SPRAY POLYISO FOAM STRUCTURAL-BUILDING 01 CL CENTERLINE OPG OPENING INSULATION CLG CEILING OPOI OWNER PROVIDED OWNER INSTALLED SHEET NUMBER SHEET NAME CLR CLEAR OPCI OWNER PROVIDED CONTRACTOR CMU CONCRETE MASONRY UNIT INSTALLED GYPSUM BOARD OR S0.00-01 GENERAL STRUCTURAL NOTES&SCHEDULES COL COLUMN PC PRECAST CONC CONCRETE PF PREFINISHED C9'-O" CEILING HEIGHT FIBERGLASS- S1.01-01 FOUNDATION&1ST LEVEL WALL FRAMING PLANS CONT CONTINUOUS PJ PANEL JOINT REINFORCED GYPSUM S1.02-01 LEVEL 2&3 FLOOR&FRAMING PLANS COVR COVER PL PLATE BOARD S1.03-01 LEVEL 4 ROOF FRAMING&ROOF LOADING PLANS CPT CARPET PLAM PLASTIC LAMINATE S5.00-01 CONCRETE DETAILS CT CERAMIC TILE PLMG PLUMBING SHEET TITLE CTR CENTER PNL PANEL A3 PARTITION TYPE S5.01-01 FOUNDATION DETAILS DEC DETENTION EQUIPMENT CONTRACTOR PT PRESSURE TREATED WITH NO SOUND S5.02-01 FOUNDATION DETAILS(2) TITLE SHEET - DET DETENTION PTD PAPER TOWEL DISPENSER I ATTENUATION S5.03-01 STEEL FRAMING DETAILS DEMO DEMOLITION REINF REINFORCED PLYWOOD S5.04-01 WOOD FRAMING DETAILS BUILDING 01 DIA DIAMETER REQ REQUIRED DIM DIMENSION REV REVISED PARTITION TYPE S5.05-01 TRUSS LOADING DIAGRAMS DF DRINKING FOUNTAIN RD ROOF DRAIN A3 WITH SOUND S5.06-01 ROOF FRAMING DETAILS DGB DETENTION GRAB BAR RM ROOM ATTENUATION S5.07-01 ROOF FRAMING DETAILS(2) DR DOOR RO ROUGH OPENING MEP-BUILDING 01 DWG DRAWING SAP SECURE PANEL ACCESS COVER BOARD EA EACH SC SEALED CONCRETE - . . _ BUILDING SHEET NUMBER SHEET NAME EJ EXPANSION JOINT SCHED SCHEDULED EXPANSION JOINT m ELEC ELECTRICAL SEC SECURITY t ELEV ELEVATOR SECT SECTION M-2.01-01 Building 01 -Level 1 &Level 2 Mechanical Plans REVISION E EQ EQUAL SHT SHEET M-2.02-01 Building 01 -Level 3&Roof Level Mechanical Plans EQUIP EQUIPMENT SHWR SHOWER M-3.01-01 Building 01 -Unit 2.1A-Level 1 &Level 2 Mechanical Plans No. Description Date ER EPDXY TER RRSIN SK SINK CEILING SYMBOLS Y IS M-3.02-01 Building 01 -Unit 2.1A-Level 3&Roof Level Mechanical Plans EXT EXTERIOR SPEC SPECIFICATIONS M-3.03-01 Building 01 -Unit 3.2A-Level 1 &Level 2 Mechanical Plans 5 FD FLOOR DRAIN SS STAINLESS STEEL CD c FDN FOUNDATION STL STEEL M-3.04-01 Building 01 -Unit 3.2A-Level 3&Roof Level Mechanical Plans FE FIRE EXTINGUISHER STIFF STIFFENER M-3.05-01 Building 01 -Unit 2.2A-Level 1 &Level 2 Mechanical Plans FFF EL FINISH FLOOR ELEVATION STRUCT STRUCTURAL M-3.06-01 Building01 -Unit 2.2A-Level 3&Roof Level Mechanical Plans 0° FIN FINISH T&G TONGUE AND GROOVE _ "_ 71 WALL MOUNTED K + M-5.01-01 Mechanical Details FRT FIRE RESISTANT TREATED TO TOP OF " - GYP BD CEILING FLUORESCENT FIXTURE z FLR FLOOR TOF TOP OF FOOTING M-6.01-01 Mechanical Schedules 2 FS FOOD SERVICE TPH TOILET PAPER HOLDER �A� ® �® EXIT SIGNS -HATCH M-6.02-01 Mechanical Notes FT FOOT TS TUBE STEEL INDICATES EXIT TEXT E-2.01-01 Building 01 -Level 1 &Level 2 Electrical Plans FTG FOOTING TYP TYPICAL SUPPLY AIR AND ARROW E-2.02-01 Building01 -Level 3&Roof Level Electrical Plans FUT FUTURE UNO UNLESS NOTED OTHERWISE GA GUAGE VAR VARIES � INDICATES DIRECTION E-3.01-01 Building 01 -Unit 2.1A-Level 1 &Level 2 Electrical Plans El o GC GENERAL CONTRACTOR VB VAPOR BARRIER \•-'/ SMOKE DETECTOR E-3.02-01 Building 01 -Unit 2.1A-Level 3&Roof Level Electrical Plans o GL GLASS VCT VINYL COMPOSITE TILE D E-3.03-01 Building 01 -Unit 3.2A-Level 1 &Level 2 Electrical Plans `m GR GRADE VERT VERTICAL RETURN AIR r�� C' GYP BD GYPSUM BOARD VIF VERIFY IN FIELD El V SPEAKER E-3.04-01 Building 01 -Unit 3.2A-Level 3&Roof Level Electrical Plans 'al' HC HOLLOW CORE VT VINYL TILE E-3.05-01 Building 01 -Unit 2.2A-Level 1 &Level 2 Electrical Plans EXHAUST AIR / E-3.06-01 Building01 -Unit 2.2A-Level 3&Roof Level Electrical Plans HT HEIGHT VTR VENT THROUGH ROOF PROJECTOR HM HOLLOW METAL VWC VINYL WALL COVERING ® �\ E-5.01-01 Electrical Details m HORIZ HORIZONTAL W WITH E-5.02-01 Electrical Diagrams D INT INTERIOR WC WATER CLOSET a INSUL INSULTATION WD WOOD ® ACCESS PANEL -et E-6.01-01 Electrical Schedules JAN JANITOR WDW WINDOW WALL WASHER P-2.01-01 Building 01 -Level 1 &Level 2 Plumbing Plans JST JOIST WP WATERPROOF P-2.02-01 Building 01 -Level 3&Roof Level Plumbing Plans LAV LAVATORY WT WALL TYPE © FLUORESCENT LIGHT PENDANT TYPE LIGHT P-3.01-01 Building 01 -Unit 2.1A-Level 1 &Level 2 Plumbing Plans MAX MAXIMUM WWF WELDED WIRE FABRIC FIXTURE P-3.02-01 Building 01 -Unit 2.1A-Level 3&Roof Level Plumbing Plans PROJECT NUMBER 14054.1 MECH MECHANICAL P-3.03-01 Building 01 -Unit 3.2A-Level 1 &Level 2 Plumbing Plans ISSUE DATE MAY 31,2017 SUSPENDED LIGHT P-3.04-01 Building 01 -Unit 3.2A-Level 3&Roof Level Plumbing Plans - WALL MOUNTED LIGHT FIXTURE P-3.05-01 Building 01 -Unit 2.2A-Level 1 &Level 2 Plumbing Plans - a, I- I SUSPENDED P-3.06-01 Building 01 -Unit 2.2A-Level 3&Roof Level Plumbing Plans SHEET NO. , v, N FLUORESCENT LIGHT DOWNLIGHT P-5.01-01 Plumbing Details 0 P-6.01-01 Plumbing Schedules \ ■ O 0 O 1 N. CHANDELIER ? < STRIP LIGHT P-6.02-01 Plumbing Notes&Specifications N P-0.01-1 MEP Site Plan m